• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 3
  • Tagged with
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energikartläggning av Masurgårdens förskola : Åtgärder och dess potentiella energi- och kostnadsbesparing

Lindberg, Joakim January 2014 (has links)
Arbetet syftar till att åskådliggöra energianvändningen i Masurgårdens förskola samt kontrollera om fastighetens energisystem används optimalt. Kartläggningen syftar till att förse fastighetsägaren med beslutsunderlag för framtida investeringskalkyler och energi-besparingsåtgärder.En modell av fastigheten skapades i energisimuleringsprogrammet IDA ICE, klimat-skalet återskapades från konstruktionsritningar, belysning och personbelastning inven-terades på plats. Resterande indata var baserat på nyckeltal från tidigare studier och schablonvärden.Simuleringsresultaten visar att fastigheten inte är i behov av några större investeringar i energibesparande åtgärder. Men det konstateras att en årlig energibesparing på 5308 kWh (5,6 %) är möjlig genom en sänkning av uteluftsflöde under vintermånaderna och genom att byta ut radiatortermostaterna mot nya. Åtgärderna leder även till en förbättring av inomhusmiljön och tros minska problemen med torra slemhinnor under vintermånaderna hos brukarna. / This work aims to illustrate the use of energy in Masurgårdens förskola and verify that the property's energy is used optimally. The survey seeks to provide the landlord with decision support for future investment calculations and energy saving measures.A model of the building is created in the energy simulation program IDA ICE, the building envelope was recreated from the buildings blueprints, lighting and personal load was inventoried. The remaining input data were taken from previous studies or from standard values.Simulation results show that the building is not in need of significant investment in energy saving measures. But it is found that annual energy savings of 5308 kWh (5.6%) is possible by lowering the outdoor airflow during winter months and by replacing the radiator thermostats with new ones. The measures also leads to an improvement of indoor environment and is believed to reduce the problem with mucosal dryness on the buildings occupants during the winter months.
2

Energikartläggning och utredning av alternativa energikällor för ett enfamiljshus i timmer byggt år 1850

Kapke, Holger, Gustafsson, Ingmar January 2015 (has links)
No description available.
3

Att utvändigt värmeisolera köldbryggor i utkragade balkonggolv : En fallstudie om energianvändning, kostnader och påverkan av byggnadens yttre gestaltning

Axner, Emil January 2015 (has links)
I hopp om att Sverige ska uppnå sina miljömål ställs hela tiden högre krav på byggnaders energianvändning. Ett första steg bör vara att förbättra byggnadens förmåga att behålla värmen. Dessa förbättringsåtgärder innebär att klimatskärmen blir mer värmeisolerande och att köldbryggor i olika konstruktionsdetaljer begränsas. Ett återkommande problem är dock att när befintliga byggnader renoveras finns gällande varsamhetskrav som påverkar möjligheterna för hur arbetet får utföras. Värdebärande egenskaper ska nämligen bevaras även om det innebär merkostnader vid renoveringar. Detta examensarbete syftar till att studera energianvändningen för köldbryggor som uppstår i utkragade balkonggolv och hur energianvändningen påverkas då balkongplattan tilläggsisoleras. Studien omfattar även den påverkan detta får på byggnadens yttre gestaltning och huruvida investeringskostnaden är ekonomiskt försvarbar ur ett livscykelperspektiv jämfört med energibesparingen. Resultatet visar att dessa köldbryggor ökar energianvändningen med närmare 4000 kWh per år och byggnad och att tilläggsisoleringen av balkonggolven minskar denna användning med ungefär 75 %. Utifrån aspekten att studera huruvida tilläggsisoleringen påverkar byggnadens yttre gestaltning visar resultatet även att förändringen är marginell. Bedömningen är därför att tilläggsisoleringen inte påverkar byggnadens gestaltning. Jämförandet av investeringskostnaden med energibesparingen ur ett livscykelperspektiv visar att materialkostnaden är för hög samtidigt som energipriset är för lågt för att generera någon vinst under den valda kalkylperioden. / In order for Sweden to reach its goals for a sustainable future, the government continues to increase demands on improving energy efficiency of buildings. A first step should be to improve the buildings ability to keep its heat. This means that the thermal insulation of the envelope should be improved and effect of thermal bridges in various constructions be minimized. A recurrent problem when renovating already existing buildings is the requirement of preservation and how that affects the possibilities on how to renovate. All buildings constitute a storytelling that illustrates how society has developed over time. Building characteristics and expressions must be preserved even if it leads to higher renovation costs. This thesis aims to study the energy use caused by thermal bridges in balcony slabs and how the energy use is affected by insulating the balcony slabs. It also investigates how the overall building appearance is affect by this figuration. And last, the study aims to explore however the investment in material is defensible when comparing it with the cost for energy in a life cycle perspective. The result shows that the thermal bridges caused by the balcony slabs increase the energy use by almost 4000 kWh per year and building and by adding insulation to the slabs, the energy usage decline by almost 75 %. In view of the buildings appearance, the additional insulation has a minimal affect. When comparing the investment cost in a life cycle perspective with the saving of energy, results shows that the costs in material is too high and at the same time the price for energy is too low for obtaining any profit for the given time period.
4

Energy Renovation of an Historic Town Using Life Cycle Cost Optimization : An Assessment of Primary Energy Use and CO2 Emissions / Energirenovering av en historisk stad genom livscykelkostnadsoptimering : En utvärdering av primärenergianvändning och CO2-utsläpp

Milić, Vlatko January 2016 (has links)
Historic buildings, buildings built before 1945, represent a third of the total building stock in Sweden. While implementing energy efficiency measures (EEMs) on historic buildings it is important to consider heritage values. This thesis aims to investigate impacts on primary energy use and CO2 emissions while using life cycle cost (LCC) optimization on historic buildings in three studied cases: reference case with no implemented EEMs (case 1), lowest possible LCC (case 2) and a decrease by 50% in energy use (case 3). As a case study 920 historic buildings divided into twelve typical buildings (6 wood buildings, 1w-6w, and 6 stone buildings, 1s-6s) in the downtown area of Visby, Sweden, are used. Within the scope of the thesis, how to achieve the most profitable EEMs and how the profitability of energy renovation varies between the typical buildings in the studied cases will be analyzed also. An interdisciplinary method is applied in the thesis that considers both heritage values and energy savings. However, the keystone of the thesis is the use of the program Optimal Energy Retrofit Advisory-Mixed Integer Linear Programming (OPERA-MILP), which is a part of the interdisciplinary method. With the use of OPERA-MILP, the cost-optimal energy renovation strategy is obtained for a building. The program takes into account all energy-related investment costs, as well as the investment and operation costs for the heating system, during a set time period. The results show unique packages of EEMs for each of the twelve typical buildings with a potential to lower the total LCC by between 4-11% in the building stock and simultaneously decrease the energy use by more than 50%. The thesis also shows a possible decrease in primary energy use from 24%-57%. The CO2 emissions vary significantly depending on what assumptions are made related to electricity production and biomass use; the results show increases up to 224% in CO2 emissions but also decreases up to 85%. All typical buildings are economically viable to energy renovate. The LCC savings are between 1.4-11.8 SEK with a life cycle set to 50 years for every annually saved kWh, except for case 3 where cost is incurred for every annually saved kWh, 10.0-17.2 SEK, for a number of the typical buildings. / Historiska byggnader, byggnader uppförda före 1945, utgör en tredjedel av det totala byggnadsbeståndet i Sverige. Historiska byggnader har ofta kulturhistoriska värden som måste beaktas vid energieffektiviseringar. Detta examensarbete syftar till att undersöka påverkan på primärenergianvändning och CO2-utsläpp genom optimering av livscykelkostnaderna (LCC) för historiska byggnader. Som fallstudie används 920 historiska byggnader i Visbys innerstad, indelade i tolv olika typbyggnader (6 träbyggnader, 1w-6w, och 6 stenbyggnader, 1s-6s). Tre fall undersöks: referensfall utan implementerade energieffektiviseringsåtgärder (fall 1), lägsta möjliga LCC (fall 2) och en minskning av energianvändningen med 50 % (fall 3). Inom examensarbetets kommer även de mest lönsamma energieffektiviseringsåtgärderna tas fram. Examensarbetet kommer också att visa hur lönsamheten för energirenovering varierar mellan de olika typbyggnaderna. Vid utförandet av examensarbetet tillämpas en tvärvetenskaplig metod som beaktar både kulturhistoriska värden och energibesparing. Tyngdpunkten ligger dock på användningen av programmet Optimal Energy Retrofit Advisory-Mixed Integer Linear Programming (OPERA-MILP), som är en del av den tvärvetenskapliga metoden. Med användningen av OPERA-MILP erhålls den kostnadsoptimala energieffektiviseringsstrategin för en byggnad. Programmet beaktar alla energirelaterade investeringskostnader, samt investering- och driftkostnader för värmetillförselsystem, under en bestämd tidsperiod. Resultaten visar unika energieffektiviseringspaket för de olika typbyggnaderna med en potential att sänka totala LCC för byggnadsbeståndet med 4-11 % och samtidigt minska energianvändningen med mer än 50 %. Examensarbetet visar också en möjlig minskning i primärenergianvändning med 24-57 %. CO2-utsläppen varierar mycket beroende på vilka antaganden görs relaterat till elektricitetsproduktion och användning av biomassa; resultaten visar ökningar upp till 224 % i CO2-utsläpp men också minskningar ned till 85 %. Samtliga typbyggnader är ekonomiskt lönsamma att energirenovera med LCC-besparingar på 1,4-11,8 SEK med en livscykel satt till 50 år för varje årligen sparad kWh, förutom i fall 3 då kostnader uppstår för varje årligen sparad kWh med 10,0-17,2 SEK, för ett antal av typbyggnaderna. / Potential and Policies for Energy Efficiency in Swedish Buildings Built Before 1945 (Stage II) - Energy Systems Analysis
5

Jämförelse av central och lokal uppvärmning av mindre bostadsrättsförening / Comparison between central heating of small housing society with geothermal heating

Wernqvist, Jonas, Cedervall, Kalle January 2017 (has links)
Idag när bostadsmarknaden växer snabbare än på länge blir samtidigt energihushållning viktigare och viktigare. Ekonomiska och miljömässiga intressen från bostadsägare angående stigande elpriser och energihushållning leder båda till ett mer medvetet byggande vad gäller klimatskalets täthet, energismarta installationer såsom styrda FTX-system och andra besparingsåtgärder.Examensarbetet har skrivits åt Bjerking för att undersöka möjligheten till att centralisera uppvärmningen istället för att värma upp bostäderna med varsin frånluftsvärmepump i en bostadsrättsförening bestående av parhus.Rapporten innehåller en del beräkningar i form av energiförluster och kostnadsberäkningar för de olika värmesystemen samt statistik för uppvärmning i Sverige.Examensarbetet har resulterat i kostnadsberäkningar som kan användas vid inledande investeringsberäkning för centraliserad uppvärmning i liknande projekt. / Today, when the housing industry is growing faster than in a long time energy house holding is becoming more important for every day. Economic and environmental interests from house owners, when it comes to increasing energy prices and energy house holding, both leads to a more conscious house building. This includes the buildings U-value, energy smart installations and other energy saving arrangements.This examination paper has been written for Bjerking to investigate the possibility to centralize the heating in a housing society of several semi-detached houses instead of heating them locally with the standard solution, an exhaust air heat pump per apartment.This examination paper includes a few calculations of energy losses and life cycle costs for the different heating systems. It also includes a bit of statistic for different types of heating in Sweden.It has ended in cost calculations that can be used when thinking about and planning to build semi-detached houses with central heating.
6

Energy Efficiency Assessment,based on Field Measurements andComputational Simulations : A Swedish Hypermarket’s case study

Corceiro, Beatriz January 2022 (has links)
This study aims to compare the energy consumption of a supermarket according to field measurements and results from building’s simulation software. Additionally, measures of energy efficiency to minimize the energy intensity of the supermarket are investigated. For such purpose, an ICA MAXI hypermarket in Bålsta, Stockholm, with a total conditioned area of 6570 m2 has being under analysis. This hypermarket operates with a trans-critical CO2 booster refrigeration system, which allows to recover the heat taken out from the refrigeration cabinets to warm up the sales area, when necessary and the only energy source it uses is electricity. Ground source energy storage is used to store part of this heat and enable an effective space heating and domestic hot water supplies. This system is also responsible to provide the required space cooling. In that sense, the referred hypermarket is using the state of the art refrigeration system for supermarkets in cold climate’s countries. Results from the field measurements performed in 2021 showed a total electricity consumptionof 1734 MWh, which corresponds to 264 kWh/m2. This value is in accordance with several studies’ conclusions. However, the values predicted by the simulation tools appointed a lower annual consumption. EnergyPlus and CyberMart software were used to simulate the power loads of ICA MAXI. Subsequently, a Python tool was used to compute the energy consumption by the refrigeration system, taking into account the demands found on the building’s simulation tools. In the end, EnergyPlus’ model predicted an annual energy consumption of 1347 MWh, which equals 205 kWh/m2. Out of the 387 MWh gap, 266 MWh are due to the assumptions taken for the energy consumed by the electrical appliances, 120 MWh resulted from the non-optimal control strategy used on the refrigerationsystem and the remaining 48 MWh were related to different outsides temperatures, predicted on the model and field measurements. This allows to conclude that by managing the current refrigerationsystem in an optimal way, 77.6 thousands of swedish kroner may be saved and the equivalent of about 11 tons of CO2 can be avoided annually. The final results from CyberMart tool were close to the EnergyPlus’ ones and this software was found to be much more user-friendly. In addition, with the aim to identify energy efficiency measures to be applied in this hypermarket, several scenarios were constructed in EnergyPlus, by changing the temperature setpoints of the system, the infiltration rate and the store’s location. Findings pointed out that adapting the indoor temperature for Summer and Winter months can lead to energy savings. / Denna studie syftar till att jämföra energiförbrukningen i en stormarknad enligt fältmätningar och resultat från byggnadens simuleringsprogram. Dessutom undersöks mått på energieffektivitet för att minimera energiintensiteten i stormarknaden. För detta ändamål har en ICA MAXI stormarknad i Bålsta, Stockholm, med en total konditionerad yta på 6570 m2 under analys. Denna stormarknad arbetar med ett trans-kritiskt CO2 booster-kylsystem, som gör det möjligt att återvinna värmen som tas ut från kylskåpen för att värma upp försäljningsområdet, när det behövs och den enda energikälla den använder är elektricitet. Lagring av markenergi används för att lagra en del av denna värme och möjliggöra en effektiv uppvärmning av utrymmen och varmvattenförsörjning. Detta system är också ansvarigt för att tillhandahålla den nödvändiga utrymmeskylningen. I den meningen använder den hänvisade stormarknaden det toppmoderna kylsystemet för stormarknader i länder med kalla klimat. Resultat från de fältmätningar som utfördes 2021 visade en total elförbrukning på 1734 MWh, vilket motsvarar 264 kWh /m2. Detta värde överensstämmer med flera studiers slutsatser. Men de värden som förutspåddes av simuleringsverktygen utsåg en lägre årlig förbrukning. Programvaran EnergyPlus och CyberMart användes för att simulera strömbelastningarna för ICA MAXI. Därefter användes ett Python-verktyg för att beräkna energiförbrukningen i kylsystemet, med hänsyn tagen till de krav som finns på byggnadens simuleringsverktyg. Till slut förutspådde EnergyPlus modell en årlig energiförbrukning på 1347 MWh, vilket motsvarar 205 kWh /m2.Av gapet på 387 MWh beror 266 MWh på de antaganden som gjorts för den energi som förbrukas av de elektriska apparaterna, 120 MWh härrörde från den icke-optimala styrstrategin som användes på kylsystemet och de återstående 48 MWh var relaterade till olika utomhustemperaturer, förutspått på modellen och fältmätningar. Detta gör det möjligt att dra slutsatsen att genom att hantera nuvarande kylsystem på ett optimalt sätt kan 77,6 tusen svenska kronor sparas och motsvarande cirka 11 ton CO2 kan undvikas årligen. De slutliga resultaten från CyberMart- verktyget låg nära EnergyPlus och denna programvara visade sig vara mycket mer användarvänlig. Dessutom, i syfte att identifiera energieffektivitetsåtgärder som ska tillämpas i denna stormarknad, konstruerades flera scenarier i EnergyPlus, genom att ändra systemets temperaturbörvärden, infiltrationshastigheten och butikens läge. Resultaten påpekade att anpassning av inomhustemperaturen för sommar- och vintermånaderna kan leda till energibesparingar.
7

Energiutvärdering av Undervisningshuset på Kungliga Tekniska Högskolan i Stockholm : Uppföljning av energianvändning medelst normalårskorrigering / Energy evaluation of Undervisningshuset at The Royal Institute of Technology in Stockholm : Follow-up of energy use by means of standard year correction

Pehrs, Malin, Hjort, Lina January 2020 (has links)
Bostad- och servicesektorn står för cirka 40 % av den totala årliga energianvändningen i Sverige. För nybyggda hus med ambitiösa miljökrav, såsom objektet för denna studie, är en viktig del i hållbarhetsarbetet uppföljning och feedback av energianvändningen för att illustrera sambandet mellan ambition och faktiskt resultat. Energiuppföljning i Undervisningshuset, en byggnad på KTH Campus med ambitiösa visioner om hållbarhet och pedagogik, är därför syftet med denna studie. För att jämföra energianvändningen mellan olika år måste energianvändningen normaliseras vilket sker i två steg; korrigering för normalt brukande och normalårskorrigering. I denna rapport beräknas Undervisningshusets normaliserade energianvändning medelst energisignatur och graddagar, vilken jämförs med den enligt Energideklarationen förväntade energianvändningen som normaliserats med SMHI:s energi-index. Undervisningshusets energiprestanda är enligt energisignaturmetoden 56 kWh/m2 och år och enligt graddagsmetoden 59 kWh/m2 och år, jämfört med den förväntade energiprestandan i Energideklarationen på 60 kWh/m2 och år. Både resultaten för denna rapport och Energideklarationen klassificerar därmed Undervisningshuset med Energiklass B. / The housing- and service sector makes up about 40 % of the total yearly energy use in Sweden. For new buildings with ambitious requirements, such as the object of this study, an important part of the work towards sustainability is follow-up and feedback on its energy use to illustrate the connection between ambition and actual result. Energy follow-up for Undervisningshuset, a building on KTH Campus with ambitious visions of sustainability and pedagogy, is therefore the aim of this study. To compare the energy use in buildings between different years the energy use must be normalized which is done in two steps; correction for normal occupancy and standard year correction. In this report the normalized energy use of Undervisningshuset is calculated by means of energy signature and degree-days, which is compared to the expected energy use according to the Energy Declaration normalized by SMHI’s energy-index. The energy performance of Undervisningshuset is 56 kWh/m2 and year according to the energy signature method and 59 kWh/m2 according to the degree-day method, compared to the expected energy performance in the Energy Declaration of 60 kWh/m2 and year. Both the results of this report and the Energy Declaration thereby classifies Undervisninshuset with Energy Class B.
8

Embodied carbon and waste generation of building refurbishment : Case studies of office fit out in Sweden / Inbyggd kol och avfallsgenerering vid renovering av byggnader : Fallstudier av hyresgästanpassning i kontorsbyggnader i Sverige

Budiyani, Ansheila Gabriela January 2023 (has links)
Buildings contribute to various environmental impacts. Office fit out, as a type of refurbishment in the building life cycle, tends to recur often and is resource-intensive. Still few studies have researched the topic. Through four fit out case studies in offices in Sweden, this study investigates the impacts of office fit out by calculating the waste generation and embodied carbon of fit out. The results show that the waste generation and embodied carbon for each case study projects was 31-38 kg/m2 refurbished GFA and 93-96 kg CO2e/m2 refurbished GFA. Over time, the accumulated recurring embodied carbon of fit out can surpass the initial embodied carbon of the building when no improvement for embodied carbon reductions is made. Scenarios modelling explores how prolonging fit out recurrency and incorporating circular methods to the practice could reduce the accumulation of embodied carbon of fit out. According to the results, recommendations for the actors involved are proposed and methodological reflections are presented. This study provides an overview and initial understanding of the impacts of fit out from real-life cases to help identify what can be done to reduce environmental impacts. / Byggnader bidrar till olika typer av miljöpåverkan. Hyresgästanpassning i kontorsbyggnader är en typ av renovering under en byggnads livscykel som tenderar att upprepas många gånger och är resurskrävande. Trots det är det få studier som än så länge har undersökt ämnet. Genom fyra fallstudier av hyresgästanpassningsprojekt i kontorsbyggnader i Sverige studeras effekterna av hyresgästanpassning genom att beräkna generering av avfall och inbyggd klimatpåverkan (eng. embodied carbon). Resultaten visar att för de fyra fallstudierna genereras avfall i omfattningen 31-38 kg/m2 renoverad BTA och inbyggd klimatpåverkan i omfattningen 93-96 kg CO2e/m2 renoverad BTA. Över tid kan den ackumulerade inbyggda klimatpåverkan av återkommande hyresgästanpassningsprojekt överskrida byggnadens initiala inbyggda klimatpåverkan när inga strategier för att minska inbyggd klimatpåverkan tillämpas i projekten. Modellering av ett antal scenarier undersökte hur en lägre frekvens av återkommande hyresgästanpassningsprojekt och införlivning av cirkulära strategier kan minska ackumuleringen av inbyggd klimatpåverkan över byggnadens livscykel. Baserat på studiens resultat föreslås rekommendationer till berörda aktörer och reflektioner som rör beräkningsmetoden presenteras. Den här studien ger en översiktlig förståelse av klimatpåverkan av hyresgästanpassning i kontorsbyggnader från verkliga fallstudier, vilket kan bidra med att identifiera vad som kan göras för att minska miljöpåverkan.

Page generated in 0.3521 seconds