• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energianalys av fastigheten Björnen : Kvarteret Björnen i Mariestad / Energy analysis of a multi-useproperty : The block Björnen in Mariestad

Östanbäck, Kristian January 2015 (has links)
Denna rapport behandlar en energianalys av fastigheten Björnen i Mariestad. I rapportenkommer aspekter som antags vara kritiska för byggnadens energianvändning att behandlas.Exempel presenteras på hur framtagande av dokumentation och behandling av existerandesådan gjordes. Att dokumentation saknas eller inte är uppdaterad kan innebära problem dåfastigheten skall analyseras. Detta problem eftersträvas delvis att elimineras i denna rapportgenom de analyser som görs.Ett syfte med rapporten är att ta fram möjliga förtjänster som framtida energieffektiviseringsåtgärder påverkar. Exempelvis vid en renovering. Emellertid är en heltäckande förståelse förhur den i fastighetens tillförda fjärrvärmeenergi tillförs och används i byggnaden central. Enkartläggning av hur fastigheten fungerar i nuläget med till exempel energisignatur, samt samladstatistik finns också att tillgå. Detta skall fungera som ett underlag inför eventuella framtidaenergieffektiviserande åtgärder i fastigheten. / This report is covering an energy analysis of the property Björnen, Mariestad. The report willcover aspects assumed to have a critical impact on the energy use of this property in particular.Examples on how produce documentation and analysis of existing documentation is covered.Missing documentation or badly organized one can cause major problems in an energy analysis.This problem is sought to be partially eliminated through this report.One purpose of this report is to declare possible profits that may be the result of proposed energyefficiency actions regarding this property. Actions such as renovation. The central purpose,however, is to create an understanding of how this property in particular is using the energydelivered to it. A survey of how the property is functioning in these aspects with appurtenantstatistics and analysis are covered. This should act as a base of thought to consider for possibleactions taken with this property in the future.
2

Verifiering av beräknad energiprestanda för flerbostadshus byggda år 2007-2009

Haglund, Jonatan, Svedlund, Marcus January 2012 (has links)
The building industry consumes approximately 40 % of the total energy consumption in Sweden, where the using stage is dominating with 80 %. There is a lot of work in progress to reduce energy use in the building industry, and the demands from authorities regarding energy use increases. As a part of this work Building and planning department of Sweden has established a requirement that has been applied since 2006, and restricts a maximum energy use for buildings.The requirement includes that an energy simulation must be done in advance to demonstrate that it is possible to meet the demands. Reality is however more complex than an energy simulation program, that frequently underestimates the energy use of buildings. The purpose of this thesisis to study and analyse deviations between estimated and actual energy use in modern apartment buildings. The study includes four apartment buildings in Stockholm, Gothenburg and Jönköping that were built in 2007-2009. The thesis is done in collaboration with Riksbyggen. Riksbyggen have built and manage the buildings. The energy simulations have been executed in Enorm 2004 and VIP+ 5.2. All the buildings show a higher energy use than were simulated. The deviations are small for the overall use, between 1 and 8,6 %, except for one of the building with a deviation of 20 % higher energy use than simulated. For individual measurements however, there are large differences. The larges deviation is for heating, which were underestimated, up to 50 %. The main reasons of deviation are an underestimation of indoor temperature and no consideration of manual ventilation and culvert losses. Hot tap water on the other hand has been overestimated up to 57 %. One reason is high standard values when calculating.The whole difference does not necessarily depend on miscalculations. Errors can also occur when separate measurement of hot water is not available and an assessment must be made by hot water proportion of total water consumption. The result is the basis for following conclusions and recommendations: A higher indoor temperature than the current recommendation of 21 °C should be considered when calculating. Use of standard values for tap water should be made with caution, as these tend to be exaggerated. A manual ventilation supplement of 4 kWh/m², year has been proven to reduce deviations in heating requirements. Comparison between calculated and declared energy use should be made by individual measurement instead of total energy use. IMD (individual measurement and billing) provides, in addition to energy savings, a more reliable follow-up. / Av hela Sveriges energikonsumtion står byggsektorn för cirka 40 %, där bruksskedet är dominerande med cirka 80 % av den totala energiförbrukningen under byggnadens livscykel. Arbetet kring att minska sektorns energibehov pågår,och kravet på minskad energianvändning i byggnader ökar. Som ett led i arbetet har Boverket sedan 2006 ställt krav på högsta tillåten energianvändning förbyggnader. Vid projektering ska därför en energiberäkning göras för att säkerställa att byggnaden uppfyller gällande krav. Verkligheten är mer komplex än vad som kan simuleras i ett energiberäkningsprogram, och dessa tenderar ofta att underskatta byggnaders energianvändning. Examensarbetet syftar därför till att studera och analysera avvikelser mellan beräknad och faktiskt energianvändning för nybyggda flerbostadshus. Totalt har fyra fastigheter, färdigställda mellan 2007 och 2009, i Stockholm, Göteborg och Jönköping studerats. Examensarbetet är gjort i samarbete med Riksbyggen, som har byggt och förvaltar de studerade fastigheterna. Fastigheterna har beräknats i programmen Enorm 2004 och VIP+ 5.2, och församtliga redovisas en högre energianvändning än beräknat. Avvikelser är dock små, mellan 1 % och 8,6 %, för den totala energianvändningen med undantag för en fastighet som har 22 % högre användning än beräknat. Däremot finns stora skillnader för enskilda mät värden. Störst är avvikelserna för uppvärmning, där beräkningarna underskattade denna med upp till 50 %. Anledningar till avvikelse är underskattad rumstemperatur och att ingen hänsyn till vädring och kulvertförluster tagits vid beräkning. För tappvarmvatten gäller däremot det omvända då detta överskattades i beräkningar med upp till 57 %. En anledning är höga schablonvärden vid beräkning. Hela avvikelsen behöver dock inte bero på missbedömning och felberäkning i projektering, utan fel kan dock också uppstå när separat mätning av tappvarmvatten saknas och en bedömning måste göras av varmvattenandel av total vattenförbrukning. Resultatet ligger till grund förföljande slutsatser och rekommendationer: En högre innetemperatur än dagens rekommendation om 21 °C bör övervägas vid dimensionering. Användning av schablonvärden för tappvarmvatten bör göras med försiktighet, då dessa tenderar att vara för stora. Ett vädringstillägg på 4 kWh/m², år har visat sig minska avvikelser i uppvärmningsbehov. Jämförelse mellan beräknad och deklarerad energianvändning bör göras per mätslag istället för total energianvändning. IMD (individuell mätning med debitering) ger, förutom energibesparing, en mer tillförlitlig uppföljning.
3

Inventering av lågenergibyggnader : Erfarenheter från tre demonstrationsprojekt i Örebroregion

Saevarsdottir, Sigrun January 2013 (has links)
Allt sedan oljekriserna på 1970-talet har intresset för energieffektivt byggande växt i Sverige. Idag finns det politiskt fastlagda mål inom EU om att energieffektivisera och från och med 2021 ska alla nya hus som byggs inom EU vara Nära Noll Energi-hus (NNE-hus). Definitionen för vad som är ett NNE-hus får medlemsländerna göra själva. För att snart kunna bygga lågenergihus i stor skala behövs uppföljnings- och informationsinsatser från demonstrationsprojekt. Kvaliteten på energiberäkningar behöver också höjas nu när efterfrågan av energieffektiva byggnader är större som kräver uppföljningsunderlag från olika fastigheter. Syftet med denna studie är att bidra till kunskaperna om erfarenheter från demonstrationsprojekt inom lågenergibyggnader med fokus på flerbostadshus med solfångare. Studien är uppdelad i tre delar. Den första delen består av litteraturöversikt av energibalansberäkningar, olika koncept inom lågenergihus, åtgärder för att kunna skapa lågenergihus samt drifterfarenheter från olika lågenergibyggnader såväl i Sverige som internationellt. Den andra delen består av fallstudier av tre demonstrationsprojekt i Örebro region. Projekteringsdata från fastigheterna samt uppmätt energiförbrukning erhölls och analyserades. Studiens tredje del består av kvalitativa intervjuer med byggherrarnas representanter om deras erfarenheter av projekten från idéutveckling till idrifttagning. Intervjuerna var öppet riktade och spelades in. Det första projektet var passivhusen vid Rynningeåsen som uppfördes av Asplunds Bygg AB. Byggnaderna blev färdigställda i maj 2010 och består av 13 bostadsrätter som fördelas på fyra huskroppar. Den årliga energianvändningen för värme erhölls inte från projektet och därmed kunde inte uppmätt specifik energianvändning tas fram. Å andra sidan kunde det konstateras, med hjälp av uppmätt elförbrukning i bostadsrättsföreningen, att solfångarsystemets årsprestanda låg långt under ett teoretiskt värde för värmeproduktion från solfångaranläggningar i Sverige. Årlig årsproduktion beräknades vara 180 kWh/m2 respektive 90 kWh/m2 och för det första respektive det andra året i drift. Det andra projektet som undersöktes var passivhusen i Frövi uppförda av Lindesbergsbostäder AB. Projektet färdigställdes i september 2010 och består av 16 hyresrätter som fördelas på fyra byggnader. Den specifika energianvändningen (korrigerad med graddagar) mättes till 50,8 kWh/m2 och år. Det tredje projektet var lågenergihusen i Kvarteret Pärllöken i Örebro uppförda av Örebrobostäder AB. Projektet blev färdigställt i februari 2011 och består av 24 hyresrätter fördelade på två punkthus. Husen har betongstomme och installerades bergvärmepumpar för värme- och varmvattenproduktion i husen. Den specifika energianvändningen (korrigerad med graddagar) mättes till 31,1 kWh/m2 och år i lågenergihusen i Kv. Pärllöken. Passivhusen i Frövi och lågenergihusen i Kv. Pärllöken har energiprestanda som är 44 respektive 65 % bättre än krav i BBR 19 samt uppfyller passivhusen i Frövi krav för passivhus i Sveriges Centrum för Nollenergihus. Trots låg energianvändning i båda projekten överskred den uppmätta energianvändningen (korrigerad med graddagar) den beräknade med 36 respektive 63 % i lågenergihusen i Kv. Pärllöken respektive passivhusen i Frövi. Resultaten visar att det går att bygga byggnader med låg energianvändning i Örebroregion men avvikelser mellan uppmätt och beräknad energianvändning är hög. I allmänhet underskattades de flesta delposterna i byggnadernas specifika energianvändning i projekteringen. Datorsimuleringar för solfångarprestanda skiljde mycket åt mellan projekten. De både underskattade och överskattade solfångarnas årsprestanda jämfört med vad ett bra system med plan solfångare möjligen kan ge i Sverige. Det berodde på olika indata som användes till simuleringarna. Enligt intervjuer med byggherrarnas representanter hade alla projekten det gemensamt att projekteringen tog lång tid och blev dyr. Produktionen gick bra men under idrifttagningsskedet började oväntade problem att uppstå som två av byggherrarna fortfarande höll på med att lösa två år efter färdigställandet. / In 2010 the EU adopted the Energy Performance of Buildings Directive 2010/31/EU which requires Member States to ensure that by 2021 all new buildings are so called nearly zero-energy buildings. To set minimum requirements for the energy performance of the nearly zero-energy buildings are the sole responsibility of Member States. The objective with this study is to provide further real-world data about low-energy buildings in Sweden. The study comprises case studies which investigates three demonstration projects for low-energy buildings in the Örebro Region. All investigated projects are apartment buildings with solar collectors to reduce bought energy for hot water consumption. One of these objects, the passive houses in Frövi, was studied in more detail than the others. Qualitative interviews with the developers were also used to gain further knowledge about the projects. In general the measured energy consumption, corrected to a normal year, was higher than calculated by tens of percent. Still an energy saving was gained up till 65 % compared to the maximum allowed energy consumption according to the latest building regulations in Sweden, BBR 19. The measured annual bought energy for space heating, domestic hot water and common electricity was 50,8 kWh/m2 and year in the passive houses in Frövi. In the low-energy houses in Pärllöken, Örebro it was 31,1 kWh/m2 and year. The origin for the higher measured energy consumption compared to the calculated results did vary between the projects. The results from the simulations for the solar collectors did differ a lot between the projects and compared to general performance of solar collectors in Sweden. According to the projects developers the design stage was time consuming and expensive in all the projects. No problems occurred under the construction stage but under the buildings commissioning process some unforeseen problems occurred that two of the developers were still solving two years after occupancy.
4

Kv. Cirkusängen : Studie av installationsprojekteringen med fokus på byggnadens Energisignatur / Kv. Cirkusängen : Study of the Building Service System Design with Focus on the Energy Signature

Stolt, Fanny January 2014 (has links)
För att uppnå Boverkets och Miljöbyggnads energi- och miljökrav finns ett intresse av att förstå fastigheters energianvändning. Fastighetsföretaget Humlegården har uppfört ett nytt huvudkontor för bankföretaget Swedbank: kv. Cirkusängen i Sundbyberg, Stockholm och Humlegården har ett intresse av långsiktig driftförvaltning och optimering av fastighetens energisystem. Detta examensarbete undersöker den manuella (statiska) och dynamiska energiberäkningen av kv. Cirkusängen med fokus på den dynamiska modellen i energi- och inomhusklimatsimuleringsprogrammet IDA ICE. Syftet med examensarbetet är att definiera kv. Cirkusängens Energisignatur för att senare kunna användas som underlag vid driftförvaltning. En byggnads Energisignatur kan definieras av uppmätt energianvändning och/eller av den dynamiska modellen i IDA ICE och kan användas vid långtidsmätning och energianalys samt för realtidsvisualisering av byggnadens energiprestanda. Genom modifiering av IDA-modellen har parametrars påverkan på energianvändningen analyserats i syfte att optimera och skapa en representativ IDA-modell och därmed en väldefinierad Energisignatur. Målet med detta examensarbete är att ge en god förståelse för hur IDA ICE kan användas för att definiera kv. Cirkusängens Energisignatur.    Detta examensarbete vänder sig främst till engagerade parter inom byggsektorn; driftförvaltare, energiingenjörer, hyresgäster och myndigheter. / To fulfill the building codes of Boverket – The Swedish National Board of Housing, Building and Planning and receive the environmental certificate from SGBC – Swedish Green Building Council there is an interest in energy consumption predictions and energy monitoring. The Swedish real estate company Humlegården has constructed a new headquarter for the banking business Swedbank: kv. Cirkusängen in Sundbyberg, Stockholm, Sweden and Humlegården has an interest in long-term energy management and optimization of the property´s energy system. This Master thesis investigates the static and dynamic energy calculations of kv. Cirkusängen focusing on the dynamical model in Indoor Climate and Energy simulation software IDA ICE. The purpose of the thesis is to define the Energy Signature of kv. Cirkusängen to be used as basis for the energy management. A building´s Energy Signature can be defined by measured energy consumption and/or by the dynamical model in IDA ICE and can be used for long-term measurement and energy analysis and real-time visualization of consumed energy. The IDA model of kv. Cirkusängen has been modified to investigate the impact of certain parameters on the energy consumption. The aim has been to optimize and create a representative IDA model and thereby create a well-defined Energy Signature. Furthermore, the aim of the thesis is to give a good understanding of how IDA ICE can be used to define the Energy Signature of kv. Cirkusängen.
5

Uppskattning av vindklimat – Implementering och utvärdering av en metod för normalårskorrektion

Helmersson, Irene January 2010 (has links)
The expected technical lifetime for a wind turbine is 20-25 years (Wizelius, 2007). In the process of planning a wind farm on a site an estimation of the average wind speed and the energy yield is required from the site. Due to large fluctuations in wind velocity from one year to another it is, from a climatologically point of view, not sufficient to measure the wind for a short period of time, e.g. one year. The year measured may have uncommonly high or uncommonly low winds and thereby generate an average not representative of the wind climate on the site. In the same time it is neither practical nor economically desirable to measure for a longer time period. Instead the measured data collected for a short period of time is scaled into a normal year before it is used to calculate the energy content. This normal year correction can be preformed using different methods. Principally, the methods relate the short time series, measured on the site, to one or more variables of a long time reference series. As a long time reference series the geostrophic wind on the site or a series of measured wind nearby can be used. If the correlation between the two series is sufficiently high a normal year correction may be done using the relation. Normal year correction has foremost been done using the relation between the velocities of the measured wind and a reference wind. The purpose in this study is to evaluate and implement a part of an algorithm for normal year correction considering additional variables besides wind velocity. The relationships studied are between measured wind speed and geostrophic wind speed, geostrophic wind direction and time of the year. For the purpose of evaluating the algorithm two wind data series from Näsudden, on the Swedish island of Gotland, for a period of 15 years has been used. Measured wind on 75 meters and geostrophic wind on 850hPa. Where the geostrophic wind has been used as a long time reference and the measured wind for one year at the time has been related to this reference. The relation has then been used together with the geostrophic wind data to create an estimation of the wind climate on Näsudden in three steps. Step one establishes the estimation due to the relation of geostrophic wind speed. Step two corrects the estimation due to the relation of geostrophic wind direction and step three corrects the estimation due to the relation of time of year. The conclusions from this study showed that with the method used for implementing the algorithm the normal year correction using only the relation between the velocities of the measured wind and the geostrophic wind gives the best estimation of the climatically mean wind speed. The standard deviation gives a 5 % risk for more than 0.436 m/s error for estimation of the mean wind on the site, which is comparable to earlier studies. The introduction of the wind direction dependence overestimates the mean wind on the site and amplifies the error. The introduction of the season dependence amplifies the error further and overestimates the mean wind additionally. / En vindturbin har en planerad livslängd på 20-25 år (Wizelius, 2007). Vid planering av en vindkraftspark behöver en estimering av medelvinden och energiutvinningen utföras för platsen man är intresserad av. På grund av stora fluktuationer av vindhastighet från år till år är det ur klimatologisk synpunkt inte tillräckligt att mäta under en kort period, exempelvis ett år. Det år man mäter kan ha ovanligt starka eller ovanligt svaga vindar och ge en icke representativ bild av vindklimatet på platsen. Samtidigt är det inte praktiskt eller ekonomiskt önskvärt att mäta under en längre tidsperiod. Istället kan den korta mätserie som insamlats korrigeras till ett normalår med hjälp av en långtidsreferens innan den används för att beräkna energiinnehållet. I princip går normalårskorrigering ut på att relatera den korta mätserien till en eller flera variabler i långtidsreferensen. Som långtidsreferensdata kan den geostrofiska vinden på platsen eller en lång mätserie från en närliggande plats användas. Om korrelationen mellan de två serierna är tillräckligt hög kan en normalårskorrigering göras med hjälp av relationen. Tidigare har man vid normalårskorrigering främst sett till relationen mellan vindhastigheterna för den uppmätta vinden och en referensvind. Syftet i detta arbete är att utvärdera en del av en algoritm för normalårskorrigering där hänsyn tas till fler variabler än endast vindhastighet. Samband som studeras är mellan uppmätt vindhastighet och geostrofisk vindhastighet, geostrofisk vindriktning och tid på året. För utvärderingen av algoritmen har två vinddataserier från Näsudden på Gotland använts för en period av 15 år med uppmätt vind på 75m och geostrofisk vind på 850hPa. Där den geostrofiska vinden fått representera långtidsreferensen och den uppmätta vinden för ett år i taget har relaterats till denna. Efter normalårskorrigeringen har den uppmätta vinden för 15 år fått representera vindklimatet på platsen som jämförelse. Enligt algoritmen har uppskattning av vindklimatet på Näsudden skapats i tre steg. Steg 1 är en uppskattning av vinden från sambandet för geostrofisk vindhastighet. Steg 2 är en korrektion av uppskattningen genom sambandet till geostrofisk vindriktning och steg 3 en korrektion av uppskattningen genom sambandet till tid på året. Efter vart steg skickas det aktuella estimatet vidare till nästa steg där det korrigeras med avseende på nästa samband. Slutsatserna från undersökningen visade att med den metod som använts ger normalårskorrigeringen med enbart sambandet till hastighet bäst uppskattning av den klimatologiska medelvinden. Standardavvikelsen för estimatet ger 5 % risk för mer än 0,436 m/s fel vid uppskattning av klimatologisk medelvind vilket är jämförbart med tidigare studier. Vidare överskattar införandet av vindriktningsberoendet den uppskattade medelvindhastigheten samt ökar osäkerheten. Även införandet av säsongsberoendet överskattar medelvindhastigheten ytterligare samt även osäkerheten.
6

Energiutvärdering av Undervisningshuset på Kungliga Tekniska Högskolan i Stockholm : Uppföljning av energianvändning medelst normalårskorrigering / Energy evaluation of Undervisningshuset at The Royal Institute of Technology in Stockholm : Follow-up of energy use by means of standard year correction

Pehrs, Malin, Hjort, Lina January 2020 (has links)
Bostad- och servicesektorn står för cirka 40 % av den totala årliga energianvändningen i Sverige. För nybyggda hus med ambitiösa miljökrav, såsom objektet för denna studie, är en viktig del i hållbarhetsarbetet uppföljning och feedback av energianvändningen för att illustrera sambandet mellan ambition och faktiskt resultat. Energiuppföljning i Undervisningshuset, en byggnad på KTH Campus med ambitiösa visioner om hållbarhet och pedagogik, är därför syftet med denna studie. För att jämföra energianvändningen mellan olika år måste energianvändningen normaliseras vilket sker i två steg; korrigering för normalt brukande och normalårskorrigering. I denna rapport beräknas Undervisningshusets normaliserade energianvändning medelst energisignatur och graddagar, vilken jämförs med den enligt Energideklarationen förväntade energianvändningen som normaliserats med SMHI:s energi-index. Undervisningshusets energiprestanda är enligt energisignaturmetoden 56 kWh/m2 och år och enligt graddagsmetoden 59 kWh/m2 och år, jämfört med den förväntade energiprestandan i Energideklarationen på 60 kWh/m2 och år. Både resultaten för denna rapport och Energideklarationen klassificerar därmed Undervisningshuset med Energiklass B. / The housing- and service sector makes up about 40 % of the total yearly energy use in Sweden. For new buildings with ambitious requirements, such as the object of this study, an important part of the work towards sustainability is follow-up and feedback on its energy use to illustrate the connection between ambition and actual result. Energy follow-up for Undervisningshuset, a building on KTH Campus with ambitious visions of sustainability and pedagogy, is therefore the aim of this study. To compare the energy use in buildings between different years the energy use must be normalized which is done in two steps; correction for normal occupancy and standard year correction. In this report the normalized energy use of Undervisningshuset is calculated by means of energy signature and degree-days, which is compared to the expected energy use according to the Energy Declaration normalized by SMHI’s energy-index. The energy performance of Undervisningshuset is 56 kWh/m2 and year according to the energy signature method and 59 kWh/m2 according to the degree-day method, compared to the expected energy performance in the Energy Declaration of 60 kWh/m2 and year. Both the results of this report and the Energy Declaration thereby classifies Undervisninshuset with Energy Class B.
7

Kartläggning av grundvatten i Uppsala stad : En metod för att beräkna grundvattennivåer under ett normalår / Investigation of groundwater in Uppsala city : A method for estimating groundwater levels during a normal year

Kihlén, Erik January 2017 (has links)
För att enstaka uppmätta grundvattennivåer ska kunna användas för att kartlägga grundvattennivån även i områden där långtidsmätningar saknas behövs en korrektionsmetod. Det övergripande målet med den här studien var att sammanställa och åskådliggöra grundvattennivåmätningar som inkommit till Länsstyrelsen i Uppsala län i samband med vattenskyddsdispenser. Syftet med arbetet var att undersöka hur grundvattennivån fluktuerat i olika jordarter och ta fram en metod för att korrigera punktvis uppmätta nivåer så att de speglar grundvattennivån ett normalår. Det normalårskorrigerade långtidsmedelvärdet på en viss plats ska vara detsamma oavsett om mätningarna av grundvattennivån utförts på våren, sommaren eller hösten och det ska inte heller spela någon roll om mätningarna utförts ett regnigt eller torrt år. Långtidsmätningar av grundvattennivåer i olika jordarter studerades. Fokus låg på grundvattennivåns års- och månadsavvikelse från mätseriens uppmätta långtidsmedelvärde. Utifrån avvikelserna skapades korrektionsfaktorer som adderades till uppmätta punktmätningar av grundvattennivåer. Grundvattennivåer beräknades med den framtagna korrektionsmetoden. Dessa jämfördes sedan mot uppmätta nivåer och grundvattennivåer beräknade med S-HYPE-modellen. Metoden testades även på ett oberoende dataset från Tärnsjö och implementerades på en mindre del av grundvattennivåmätningarna i och runt Uppsala stad. För grundvattennivån i jordarterna sand och grus var variationer mellan olika år viktigast att korrigera, då inomårsvariationerna var små. Grundvattennivåerna i morän varierade kraftigt inom ett och samma år vilket resulterade i att månadskorrektionen var den viktigaste faktorn. Två typer av grundvattenkartor skapades utifrån uppmätta grundvattennivåer. Kartornas utbredning täcker Uppsala stad med omnejd. Den ena kartan visar grundvattennivån som meter under markytan. Den andra kartan visar grundvattennivån som en trycknivå i höjdsystemet RH 2000. / In areas where long-term measurements are missing, a correction method is required in order to map groundwater levels based on single groundwater level measurements. The overall objective of this study was to compile groundwater measurements submitted to the County Administrative Board as part of water protection permit applications. The aim of this work was to investigate how the water table fluctuates in different types of soil and to develop a method to correct particular measured point levels to reflect the water table in an average year. The corrected long-term average value in a specific location should be the same regardless of whether the groundwater level measurements were performed in the spring, summer or autumn, nor should it matter if the measurements were done in a rainy or dry year. Long-term measurements of groundwater levels in different soil types were studied. The focus was the annual and monthly deviation of groundwater levels from the long-term average. Based on the deviations correction factors were created that were applied to the point measured groundwater levels. Groundwater levels calculated with the produced correction model were compared to the measured levels as well as the groundwater levels calculated by the S-HYPE model. The method was also tested on an independent data set from Tärnsjö and implemented on a smaller portion of the groundwater level measurements in and around the city of Uppsala. For groundwater levels in sand and gravel formations, it was important to correct for the variations between years, while the variations within the same year were small. Groundwater levels in till varied widely within the same year, making the monthly correction the most important factor. Two types of groundwater maps were created from measured groundwater levels. The map distribution covers the vicinity of Uppsala city. One map shows groundwater level as meters below surface. The second map shows groundwater level as an elevation above sea level in the height system RH 2000.
8

Skillnaden mellan beräknad och uppmätt energianvändning i två olika kontorshus

Mustafa, Warid, Haidar Ghazi, Hala January 2019 (has links)
Idag finns det ett flertal krav och rekommendationer från myndigheter vilka syftar till att reglera och hålla nere energianvändningen i kontorsbyggnader. I Boverkets byggregler, BBR, finns vägledning till hur kraven kan uppfyllas. Med detta som utgångspunkt genomförs det idag energiberäkningar i projekteringsskedet för att säkerställa att den blivande verkliga energianvändningen ej överstiger den tillåtna. Tidigare studier har visat att det trots detta ändå har varit vanligt förekommande att den verkliga energianvändningen har överstigit den beräknade och i en del fall även den tillåtna.Syftet med denna studie var att undersöka om det föreligger skillnader mellan de beräknade och de uppmätta värdena för kontorshus, samt vilka de bakomliggande orsakerna är. Även en analys kring de olika faktorerna som påverkar energianvändningen har genomförts. Det innebär att för att uppfylla syftet med studien har tre frågor ställts och dessa har besvarats genom undersökningar. Frågorna är: Vad har tidigare studier inom ämnet visat? Vilka orsaker kan det finnas om det uppstår skillnader mellan det beräknade och uppmätta energivärdet? Vad kan göras annorlunda för att få ett bättre resultat?För att kunna besvara frågeställningarna har det samlats in ett års mätningar av energianvändning (uppvärmning, komfortkyla och fastighetsel) för två olika kontorsbyggnader för att kunna visa om det går att bygga energieffektiva lokaler. För respektive kontorsbyggnadhar nödvändig information samlats in från respektive byggherre som har redovisat energiberäkningar med uppskattat energibehov. Den uppmätta uppvärmningen (fjärrvärmeanvändning och uppvärmning av tappkallvatten) har normalårskorrigerats enligt energiindexmetoden för att kunna jämföras med beräknade värden. Litteraturstudie och hypoteser om orsaker till avvikelser mellan beräknat och uppmätt finns användes och analyserades noggrannare för respektive kontorsbyggnad.Den specifika energianvändningen för respektive kontorsbyggnad uppnår Miljöbyggnads kravnivå Brons respektive Silver. För kravnivån Brons gäller att den specifika energianvändningen för en tillbyggnad ska vara under 80 !"ℎ $% och för kravnivån Silver för en ombyggnad under 118 !"ℎ $%. Däremot varierar användningen av energi för uppvärmning och komfortkyla där de månadsvis uppmätta värdena för respektive kontor överstiger det beräknade under året 2017. Det finns flera orsaker till att beräknat energibehov är för lågt på grund av energiberäkningsprogrammet som använts, IDA Indoor Climate and Energy (IDA ICE). En del indata kan ha över- eller underskattats. Exempelvis kan utnyttjandet av tillskottsenergi ha överskattats. För låg innetemperatur och att ingen hänsyn till effekten av köldbryggor tas med kan bidra till att beräknat värmebehov blir för lågt.För att uppnå bättre resultat på de månadsvis uppmätta värdena för kontorsbyggnaderna krävs noggrannare energiberäkningar med realistiska indata, vilket kan innebära att alltför höga värden på energianvändning kan upptäckas och åtgärdas under projekteringsstadiet. Det krävs kunskaper om hur byggnader kan bli energieffektiva vid användning och inte endast när byggnaderna projekteras. / Today, there is a number of requirements and recommendations by government agencies which aim to regulate and reduce energy consumption in office buildings. Boverket Byggregler, BBR, provides guidance on how to meet such requirements. With this as a starting point, calculation to determine energy usage are currently carried out in the design phase to ensure the future energy consumption does not exceed the allowed rate. However, previous studies have shown it is quite common that the actual energy consumption rate exceeds the calculated or even the allowed rate.The purpose of this study is to investigate whether there are differences between the estimated and the measured values for office buildings. Additionally, this review intends to determine the underlying causes of those differences. An analysis of the various factors that affect energy use has also been conducted and the necessary information to complete such analysis has been collected through interviews with the developer.The survey, the actual energy use for the two examined offices exceeds the calculated energy consumption value. Furthermore, the survey shows near large windows, the energy usage was higher due to having more window area, resulting in heat during the summer and needs more energy for cooling down the office buildings.The specific energy use for each office building achieves Miljöbyggnad:s requirement level Bronze and Silver. For the requirement level Bronze, the specific energy use for an extension must be below 80 kWh/m^2 and for the requirement level Silver for a reconstruction shall be 118 kWh/m^2. On the other hand, the use of energy for heating and comfort cooling varies where the monthly measured values for each office exceed that calculated during the year 2017. There are several reasons why estimated energy requirements are too low due to the energy calculation program used, IDA Indoor Climate and Energy (IDA ICE). ), some input data may have been overestimated or underestimated. For example, the use of additional energy can be overestimated, too low indoor temperature and that no consideration of the effect of cold bridges can be included can contribute to the calculated heat requirement being too low. Therefore, it is too early to draw any conclusions as more and more surveys are needed before being able to generalize the results.
9

Beräkning av värmeenergiförluster i flerbostadshus genom analys av den totala fjärrvärmeenergianvändningen : / Calculation of the thermal energy losses in apartment buildings through analyze of the total district thermal energy consumption :

Fredhav, Dennis, Briggert Sjöstrand, Carl Andreas January 2012 (has links)
This thesis has been carried out on behalf of IV Produkt AB and intends to set an average ratio of thermal energy losses in apartment buildings that were built during the 1960-1990. This shall be derived by analyzing the total district energy consumption that has been divided into three parts: heat energy losses (the actual heating requirements), the heating of domestic hot water and heating energy consumption for the controlled ventilation. Three different residential areas that were built during the years 1962-1966 and one that was built in 1993 has been analyzed. All residential areas are located in Växjö urban and contains between four and six apartment buildings. The analyzed objects have a mechanical exhaust ventilation systems and district heating as the heating method. No own laboratory work or experiments have been done in this thesis, the calculations have been done on the basis of parameters from VEAB, interviews with property managers, and literature studies. By calculations, we have got a result that is reported in Chapter 6. The result is given as a thermal energy loss as a percentage of the total heat consumption. In this thesis there has also been a review of the rules on requirements for the specific energy consumptions in buildings, indoor environment and indoor temperature from the National Board of Housing and the National Board of Health and Welfare.

Page generated in 0.0857 seconds