• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 558
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • Tagged with
  • 573
  • 339
  • 89
  • 78
  • 57
  • 52
  • 49
  • 47
  • 40
  • 40
  • 37
  • 36
  • 35
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análise de equilíbrio corporal submetido á esforços de aceleração e desaceleração na direção antero-posterior: estudo transversal

Costa, Gilmar Luiz da [UNESP] 12 February 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-12Bitstream added on 2014-12-02T11:21:16Z : No. of bitstreams: 1 000791898.pdf: 3496187 bytes, checksum: 85c1ac51140703b11f53a3e5648cbc97 (MD5) / O presente trabalho teve como objetivo analisar o equilíbrio postural de um indivíduo quando submetido á esforços de aceleração e desaceleração na direção antero-posterior, submetido a um sistema que simula o transporte coletivo. O sistema proposto foi constituído de uma plataforma, com movimentação no sentido antero-posterior, com duas velocidades, e com uma amplitude de movimento de 30 mm, sendo acionado por um motor DC. Durante a movimentação da plataforma de movimento, as forças de reações verticais foram registradas através de uma plataforma de força. Enquanto um acelerômetro instalado na plataforma de movimento registrou as acelerações das duas velocidades (0,6 e 2,0g). As coletas de dados foram feitas em 12 indivíduos, masculinos, jovens com faixa de idade entre 19 e 27 anos. Cada indivíduo foi submetido a duas diferentes acelerações, sendo uma considerada normal e outra sendo considerada limite para um transporte coletivo. Os desequilíbrios da postura ereta bipodal, foram avaliados através das distribuições das cargas entre o calcâneo e as pontas dos pés. Os resultados apresentaram que: no instante inicial do movimento da plataforma, os desequilíbrios dos indivíduos foram mais acentuados, sendo a diferença entre as duas velocidades na faixa de 50 % em média, das forças de reações, e após alguns instantes os indivíduos conseguem readquirir o equilíbrio inicial. Na parada repentina da plataforma acontece um novo desequilíbrio, mas neste caso as diferenças são da ordem de 5%, das forças de reação, independente das velocidades / The object of the present study is to analyze the postural balance of an individual when subjected to effects of acceleration and deceleration in the antero-posterior direction, submitted to a system that simulates the mass transportation. The proposed system consists of a platform, with movement in the antero-posterior direction, with two speeds, and a range of motion about 30 mm, being driven by a DC motor. During the platform movement, the vertical reaction forces were recorded using a force platform, connected to a data acquisition system. An accelerometer installed on the platform to records the accelerations of the two speeds (0.6 and 2.0 g). The data collections were made using 12 individuals, male, young, with range of age between 19 and 27 years. Each person was submitted to two different accelerations, one normal and the other considered the threshold for public transportation. Imbalances in bipedal stance, were evaluated through the distribution of loads between the heel and toes. The results showed that: In the first stance of the platform, the imbalances of individuals were more pronounced, and the difference between the two speeds is around 50% on average for the forces of reaction. And after a while, people were able to regain the original balance. When the platform sudden stops, a new imbalance happens, but in this case the differences are of the order of 5%, between the reaction force regardless of speed
72

Um Modelo para calibração de câmaras digitais baseado em linhas retas

Telles, Sandra Stephan de Souza [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:25Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T20:28:45Z : No. of bitstreams: 1 telles_sss_me_prud.pdf: 1366929 bytes, checksum: 8f13eb812304d2c1702fcb81ecb51119 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Com o aumento do uso das câmaras digitais não métricas em aplicações fotogramétricas, tem crescido a necessidade pela calibração destas câmaras e pela freqüência de realização desta. Com o objetivo de tornar mais simples a utilização e a automação desta etapa, foi desenvolvido um modelo matemático para calibração que usa feições retas, baseado no modelo dos planos equivalentes, com estimação dos parâmetros pelo método combinado. O modelo foi implementado em linguagem C++ em conjunto com o método convencional que usa as equações de colinearidade, de modo a permitir tanto a calibração com pontos quanto com retas. O método foi testado com dados simulados e dados reais e apresentou resultados satisfatórios, compatíveis com o modelo convencional. Para os experimentos com dados reais, foi ainda implementado um programa de extração de bordas com precisão subpixel. / Nowadays, digital cameras have been more and more employed in photogrammetric applications. However, the geometric of common camera is not rigid as metric cameras. Therefore, the need for camera calibration has been increasing; moreover it is important to be frequent. The use of straight lines can lead to an easy and fast camera calibration process due to the promising possibility of automation in the line extraction process. Following this thought, a mathematical model, based on the model of equivalent planes, was developed to include inner orientation parameters, using straight lines. This model was implemented using the unified method of adjustment with weight constraint to the parameters. The implemented program was tested using simulate and real data. The results have shown the developed model is comparable to the conventional one using control points. A feature extraction method aiming sub-pixel precision was implemented as well.
73

Determinação do erro ciclico em distanciometros eletronicos

Cordini, Jucilei January 1991 (has links)
Orientadores: Alvaro Doubek e Milton de Azevedo Campos / Dissertação (mestrado) - Universidade Federal do Paraná / Resumo: A calibração completa de um IMED envolve várias determinações de erros sistemáticos, cujos valores se modificam em função do uso constante e envelhecimento do equipamento. Parte desta calibração destina-se à determinação do erro cíclico em laboratório, normalmente conduzida sobre uma Linha de Teste. Este trabalho foi orientado no sentido de implementar e tornar operacional a Linha de Teste da UFPr , afim de adequá-la à seus propósitos e se transformar num instrumento útil para pós-graduandos, pesquisadores e usuários. Dentre os trabalhos executados e melhorias introduzidas à Linha de Teste, destaca-se a implantação de cinco sistemas refletores (espelhos) que possibilita a obtenção de distâncias superiores a 100 metros. Seis instrumentos de MED foram testados utilizando-se 03 e 05 espelhos normais, num total de 12 testes realizados; dois testes adicionais com espelhos frontais foram também realizados. Os resultados são apresentados e comprovam a eficiência do método e a praticidade do procedimento adotado. / Abstract: The complete calibration of a EDMI implicate in many determinations of systematic errors, whose values modify as a function of the constant use and the aging of the equipment. Part of this calibration is for determination of the cyclic error in laboratory, normally carried out over a Test Line. This work was oriented in the meaning of to implement and at turning operational the Test Line of the UFPr, with the aim to adapt it to its purpose and at turning it a useful instrument to post-graduate, researchers and users. Among the work carried out and the improvement introduced to the Test Line, it must be distinguished the implantation of five reflector systems (mirrors) that make possible to obtain distances over a hundred meters. Six EDMI instruments were tested by the use of three and five normal mirrors making a total of twelve realized tests; two supplementary tests with frontal mirror were also realized. The results are show and they confirm the efficiency of the method used and the practicality of the procedure adopted.
74

Desenvolvimento de modelos quimiométricos associados à espectroscopia no infravermelho para determinação de parâmetros físico-químicos do óleo diesel

Nespeca, Maurílio Gustavo [UNESP] 21 May 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-05-21Bitstream added on 2014-06-13T20:59:13Z : No. of bitstreams: 1 nespeca_mg_me_araiq.pdf: 1633750 bytes, checksum: cb5fcc59adcaa9d8548eb6bb3fb6e853 (MD5) / Tendo em vista que o óleo diesel é o derivado energético do petróleo mais consumido no Brasil, torna-se imprescindível o desenvolvimento de métodos de monitoramento capazes de avaliar a qualidade deste combustível de forma rápida, econômica e não destrutiva. Deste modo, este trabalho teve como objetivo o desenvolvimento de modelos quimiométricos com capacidade de estimar os parâmetros físico-químicos do óleo diesel (mistura B5) através de análises espectroscópicas nas regiões do infravermelho médio e próximo. Os parâmetros físico-químicos estimados foram: teor de biodiesel; massa específica; pontos de ebulição das frações 10%, 50% e 85% destiladas, índice de cetano; enxofre total e ponto de fulgor. Em oito meses, 409 amostras de óleo diesel S1800 e S500 da região Centro-Oeste Paulista foram selecionadas de forma representativa por Análise Hierárquica de Agrupamento e divididas em conjuntos de calibração (273 amostras) e validação (136 amostras). Os valores de referência foram obtidos por meio de ensaios realizados utilizando-se métodos ABNT e ASTM, estabelecidos na Resolução ANP Nº 65 de 2011. Os modelos de calibração foram desenvolvidos através dos métodos de regressão Mínimos Quadrados Parciais (PLS) e Regressão por Componentes Principais (PCR), avaliando-se o uso de pré-processamentos de dados e seleção de faixas espectrais. A validação dos modelos demonstrou que a eliminação de faixas espectrais ruidosas e o uso de derivação e suavização dos dados centrados na média resultaram em modelos mais ajustados, com maior coeficiente de correlação e menor erro de predição. Todos os modelos PLS desenvolvidos em ambas as regiões do infravermelho apresentaram valores de exatidão e precisão aceitáveis quando comparados aos valores de reprodutibilidade e repetibilidade dos... / Given that diesel is the most consumed petroleum derived fuel in Brazil, it is essential to develop monitoring methods capable of evaluating the quality of this fuel in a fast, economical and non-destructive analysis. Thus, this study aimed to develop chemometric models capable of estimating the physicochemical parameters of diesel (B5 blend) by spectroscopic analysis in the mid-infrared and near regions. The physicochemical parameters estimated were: biodiesel content, density, distillation temperatures at 10%, 50% and 85% recovery, cetane number, total sulfur, and flash point. In eight months, 409 samples of diesel S1800 and S500 of the Centro-Oeste Paulista region were representatively selected by Hierarchical Cluster Analysis and divided into sets of calibration (273 samples) and validation (136 samples). The reference values were obtained from tests using ABNT and ASTM methods, established in Resolution ANP Nº 65 of 2011. The calibration models were developed through regression methods Partial Least Squares (PLS) and Principal Component Regression (PCR), and the use of pre-processing data and selection of spectral regions were evaluated. Validation of the models demonstrated that the elimination of noisy spectral regions and the use of derivative, smooth and mean center data resulted in fitted models with higher correlation coefficient and lowers prediction error. All developed PLS models in both regions of the infrared showed acceptable values of accuracy and precision when compared to the values of reproducibility and repeatability of the reference methods. So the use of infrared spectroscopy coupled with chemometric models proved to be able to estimate the physicochemical parameters of diesel. Thus, the use of infrared spectroscopy associated with chemometric models proved able to... (Complete abstract click electronic access below)
75

Análise de equilíbrio corporal submetido á esforços de aceleração e desaceleração na direção antero-posterior : estudo transversal /

Costa, Gilmar Luiz da. January 2014 (has links)
Orientador: Tamotsu Hirata / Banca: Marcelo Sampaio Martins / Banca: Fabiano Politti / Resumo : O presente trabalho teve como objetivo analisar o equilíbrio postural de um indivíduo quando submetido á esforços de aceleração e desaceleração na direção antero-posterior, submetido a um sistema que simula o transporte coletivo. O sistema proposto foi constituído de uma plataforma, com movimentação no sentido antero-posterior, com duas velocidades, e com uma amplitude de movimento de 30 mm, sendo acionado por um motor DC. Durante a movimentação da plataforma de movimento, as forças de reações verticais foram registradas através de uma plataforma de força. Enquanto um acelerômetro instalado na plataforma de movimento registrou as acelerações das duas velocidades (0,6 e 2,0g). As coletas de dados foram feitas em 12 indivíduos, masculinos, jovens com faixa de idade entre 19 e 27 anos. Cada indivíduo foi submetido a duas diferentes acelerações, sendo uma considerada normal e outra sendo considerada limite para um transporte coletivo. Os desequilíbrios da postura ereta bipodal, foram avaliados através das distribuições das cargas entre o calcâneo e as pontas dos pés. Os resultados apresentaram que: no instante inicial do movimento da plataforma, os desequilíbrios dos indivíduos foram mais acentuados, sendo a diferença entre as duas velocidades na faixa de 50 % em média, das forças de reações, e após alguns instantes os indivíduos conseguem readquirir o equilíbrio inicial. Na parada repentina da plataforma acontece um novo desequilíbrio, mas neste caso as diferenças são da ordem de 5%, das forças de reação, independente das velocidades / Abstract: The object of the present study is to analyze the postural balance of an individual when subjected to effects of acceleration and deceleration in the antero-posterior direction, submitted to a system that simulates the mass transportation. The proposed system consists of a platform, with movement in the antero-posterior direction, with two speeds, and a range of motion about 30 mm, being driven by a DC motor. During the platform movement, the vertical reaction forces were recorded using a force platform, connected to a data acquisition system. An accelerometer installed on the platform to records the accelerations of the two speeds (0.6 and 2.0 g). The data collections were made using 12 individuals, male, young, with range of age between 19 and 27 years. Each person was submitted to two different accelerations, one normal and the other considered the threshold for public transportation. Imbalances in bipedal stance, were evaluated through the distribution of loads between the heel and toes. The results showed that: In the first stance of the platform, the imbalances of individuals were more pronounced, and the difference between the two speeds is around 50% on average for the forces of reaction. And after a while, people were able to regain the original balance. When the platform sudden stops, a new imbalance happens, but in this case the differences are of the order of 5%, between the reaction force regardless of speed / Mestre
76

Análise de materiais e técnicas de encapsulamento de módulos fotovoltaicos

Santos Júnior, Sílvio Luís dos Reis January 2008 (has links)
Made available in DSpace on 2013-08-07T18:53:53Z (GMT). No. of bitstreams: 1 000407306-Texto+Completo-0.pdf: 3963785 bytes, checksum: 3ea7aaad5a5a440440daf236d1209f00 (MD5) Previous issue date: 2008 / The goal of this dissertation was to fabricate and characterize prototypes of photovoltaic modules to analyze the encapsulation materials. The prototypes were submitted to salt spray corrosion tests, thermal cycle test, thermal cycle followed of humidity and freezing test, ultra-violet and solar radiation exposure (external exposure) test. These prototypes were optically and electrically characterized before and after each test. The tests follow standards of the Brazilian Labeling Program (PBE), Photovoltaic Energy Systems and Equipments, National Institute of Normalization, Metrology and Industrial Quality (INMETRO) and the 61215 standard of International Eletrotechnical Commission (IEC). In the visual inspection, 90 % of the samples presented no significant changes after the tests. Surface alterations in the glasses and delamination in the area next to the busbar bar of the solar cell were observed only after the thermal cycles and humidity and freezing tests. In the reflectance analysis of different regions of the prototypes, no delamination or discoloration processes were observed after the tests. In summary, considering the analysis of materials after the tests, no significant degradation of encapsulating materials EVA 485 Etimex and Akasol PTL 3-38/75 were detected neither reactions between EVA and anti-reflective TiO2 coating and screen-printing metal grid. Degradation of the electric characteristics of the prototypes were observed, with 60 % approval in the salt spray test, 75 % in the exposition to ultraviolet radiation test, 50 % in the external exposition test, 75 % in the thermal cycle test and 75 % in the thermal cycle followed of humidity and freezing test. Concerning edge seal, it was observed that Lohmann tape presented the best results for most tests, with exception to the external exposure test. / Esta dissertação teve como objetivo a fabricação e caracterização de protótipos de módulos fotovoltaicos para análise dos materiais utilizados no encapsulamento dos mesmos. Os protótipos foram submetidos a testes de corrosão por névoa salina, teste de ciclos térmicos, teste ciclo térmico seguido de umidade e congelamento, teste de exposição à radiação ultravioleta e a exposição à radiação solar (exposição externa). Estes protótipos foram caracterizados opticamente e eletricamente antes e após cada teste. Os testes foram realizados baseados nas normas do Programa Brasileiro de Etiquetagem (PBE), Sistemas e Equipamentos para Energia Fotovoltaica, Instituto Nacional de Metrologia, Normalização e Qualidade Industrial (INMETRO) e nas normas 61215 da International Electrotechnical Commission (IEC). Na inspeção visual após os testes, 90 % das amostras não apresentaram mudanças significativas. Somente após o teste de ciclos térmicos e teste de umidade e congelamento foram observadas alterações na superfície dos vidros e delaminação em área próxima a barra coletora de uma célula solar. Na análise de refletância de diferentes regiões dos protótipos não foram evidenciados processos de delaminação ou descoloração após os testes. Concluiuse que, considerando os testes realizados, não houve degradação significativa dos materiais encapsulantes EVA Etimex 485 e filme posterior Akasol PTL 3-38/75 e tampouco reações entre EVA e filme anti-reflexo de TiO2 e metalização serigráfica. Foram observadas degradações nas características elétricas dos protótipos, com um percentual de aprovação de todos os protótipos igual a 60 % no teste de névoa salina, 75 % no teste de exposição à radiação ultravioleta, 50 % no teste de exposição externa, 75 % no teste de ciclos térmicos e 75 % no teste de ciclo térmico seguido de umidade e congelamento. Em relação ao tipo de selante utilizado nas bordas dos módulos, observou-se que aqueles selados com fita Lohmann apresentaram os melhores resultados nos testes, exceto no de exposição externa.
77

Desenvolvimento e classificação de um radiômetro solar multifuncional

Souza, João Antônio Vargas de January 2010 (has links)
Made available in DSpace on 2013-08-07T18:54:48Z (GMT). No. of bitstreams: 1 000427972-Texto+Parcial-0.pdf: 121824 bytes, checksum: d5c22edd7cd93b6717cda180b10bfa36 (MD5) Previous issue date: 2010 / This study aims to develop a prototype of a portable instrument for measuring the solar irradiance with parameters comparable to solar radiometers and similar instruments. The methodology applied in this work uses the NBR ISO/IEC 17025:2005 and ISO 9060:1990. The prosed radiometer has technological innovation, it does not only measures the global and diffuse radiation as measured in commercial equipment, but it measures the levels of Ultraviolet, Visible, Infrared radiation and UV Index. Therefore, the prosed radiometer will be substitute a complete set of radiometers. The result obtained is described as follow: the step response time is below 15 seconds; the system doesn’t need adjustment of the zero; in relation to the influence of temperature, variation (percent of standard deviation) in irradiance measured by the prototype is below a 1% for variations of 50ºk; the incidence angle response of the prototype is adequateed for -80º to 80º (deviations lower than 2,5 %); the incidence directional response of the radiometer has an error in the order of 10 % and the radiometer developed has an adequate spectral response in Ultraviolet, Visible, Infrared. These tests classify the multifunctional radiometer as 1ª Class for regions of Ultraviolet and Visible and of 2ª Class for Infrared region. / Esse trabalho tem como objetivo o desenvolvimento de um protótipo portátil de um instrumento de medição da irradiância solar com parâmetros comparáveis aos radiômetros solares e instrumentos similares. Para tanto a metodologia empregada seguiu a NBR ISO/IEC 17025:2005. O radiômetro proposto tem como inovação tecnológica a determinação não só da radiação global e difusa, medidas nos equipamentos comerciais, mas também determinar os níveis de radiação Ultravioleta, Visível, Infravermelha e Índice UV solar. Portanto, o radiômetro proposto poderá substituir um conjunto completo de radiômetros. Os ensaios de classificação do radiômetro proposto, segundo a ISO 9060:1990, apresentaram o tempo de resposta do sensor à variação da intensidade de radiação inferior a 15 segundos, a não necessidade de compensação do zero e o desvio percentual de 1,1% na Não-linearidade para uma irradiância de 500Wm-2. Adicionalmente, quanto a resposta à temperatura, foram registradas variações do desvio padrão percentual na irradiância inferior a 1% para variações de 50ºk na temperatura. A resposta à inclinação do protótipo foi adequada de -80º à 80º, com erro inferior a 2,5% e a resposta direcional do radiômetro apresentou um erro máximo da resposta superior menor que 10%. O radiômetro desenvolvido apresenta seletividade espectral na região do Ultravioleta, Visível e no Infravermelho próximo. Esses ensaios classificam o radiômetro multifuncional proposto como de 1ª Classe para as regiões do Ultravioleta e Visível, sendo de 2ª Classe para a região do Infravermelho.
78

Confiabilidade metrológica de ventiladores pulmonares para cuidados críticos / Metrological reliability critical care lung ventilators

Uechi, Cristina Akemi Shimoda 20 August 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2012. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2012-11-20T13:34:54Z No. of bitstreams: 1 2012_CristinaAkemiShimodaUech.pdf: 2918809 bytes, checksum: ed08cbe55195813419e47e10451c9759 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2012-12-03T14:08:06Z (GMT) No. of bitstreams: 1 2012_CristinaAkemiShimodaUech.pdf: 2918809 bytes, checksum: ed08cbe55195813419e47e10451c9759 (MD5) / Made available in DSpace on 2012-12-03T14:08:06Z (GMT). No. of bitstreams: 1 2012_CristinaAkemiShimodaUech.pdf: 2918809 bytes, checksum: ed08cbe55195813419e47e10451c9759 (MD5) / Ventiladores pulmonares são utilizados na assistência ventilatória mecânica, suprindo o trabalho muscular necessário para a respiração em pacientes com insuficiência respiratória aguda ou crônica. A monitoração da ventilação mecânica está baseada nos sinais de fluxo, volume, pressão das vias aéreas, frequência respiratória e fração inspirada de oxigênio. Por isso, é de suma importância que os valores apresentados sejam confiáveis, o que pode ser assegurado por meio da calibração periódica. Essa pesquisa tem como objetivo propor boas práticas para o aumento da confiabilidade metrológica dos ventiladores pulmonares. Para o desenvolvimento da pesquisa foi realizada uma análise do procedimento de calibração do Hospital Universitário de Brasília e em um hospital privado. Nove ventiladores pulmonares de marcas e modelos distintos, disponíveis nos estabelecimentos assistenciais de saúde, foram calibrados conforme procedimento baseado no procedimento interno do hospital e aplicação de conceitos metrológicos. Os resultados mostram oportunidades de melhoria no processo de comprovação metrológica, como a adequação dos erros máximos admissíveis nos estabelecimentos assistenciais de saúde (EAS) e melhorias no procedimento de calibração, incluindo o aumento do número de leituras e a automação da calibração. Além disso, na estimativa da incerteza de medição verificou-se que a avaliação da incerteza Tipo B (não estatística) não pode ser descartada. O estudo também mostra que a pressão positiva ao final da expiração (PEEP) pode ter influência na calibração do volume corrente e da pressão inspiratória. Por fim, uma série de eventos não esperados no funcionamento dos ventiladores pulmonares motivou a comparação entre duas marcas distintas, que evidenciou diferenças de desempenho principalmente no comportamento dinâmico. Os resultados obtidos mostram que a metrologia ainda precisa ser disseminada em abordagens distintas e em diferentes níveis de conhecimento, com consequências no controle sanitário destes produtos para segurança de seus usuários e no incremento da qualidade da assistência. ______________________________________________________________________________ ABSTRACT / Lung ventilators are used to provide mechanical ventilation support, supplying the muscular work required for respiration in patients with acute or chronic respiratory disease. The monitoring of patient ventilation is based on signs of inspiratory flow or volume, airway pressure and oxygen concentration. Therefore, it is important that they are reliable, which can be ensured by periodic calibration. This research aims to propose best practices for increasing metrological reliability of lung ventilators used for critical care. A survey of calibration procedure used by University Hospital of Brasília - HUB and by a private hospital was done to develop the research. Nine lung ventilators, from different manufacturers and model were calibrated according to a procedure based on the hospital's internal procedure and application of metrological concepts. Results show opportunities for improvement in metrological conformity process, as suitability of maximum permissible errors and improvements in calibration procedure, including increase the number of readings and automation of calibration. Moreover, measurement uncertainty estimation should not disregard Type B (non-statistical) uncertainty. Also, it shows that pressure positive end-expiratory pressure (PEEP) may influence calibration of tidal volume and inspiratory pressure. Finally, a series of non-expected events led to comparison between two brands of lung ventilators, which mainly showed differences in their dynamic behavior. The results show that metrology has yet to be disseminated in different approaches and different levels of knowledge, with consequences to sanitary surveillance and improvement of pacient care.
79

Proposta de metodologia para a avaliação do desempenho de instrumentos de medição da qualidade da energia elétrica / Proposal methodology to evaluate the operating performance of power quality measurement instruments

Rodriguez Sañudo, Carlos Anibal 21 September 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Deparamento de Engenharia Elétrica, 2012. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-02-04T13:07:08Z No. of bitstreams: 1 2012_CarlosAnibalRodriguezSanudo.pdf: 7986861 bytes, checksum: ef729876c21927bbebee4642db4fd1da (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-02-04T14:56:19Z (GMT) No. of bitstreams: 1 2012_CarlosAnibalRodriguezSanudo.pdf: 7986861 bytes, checksum: ef729876c21927bbebee4642db4fd1da (MD5) / Made available in DSpace on 2013-02-04T14:56:19Z (GMT). No. of bitstreams: 1 2012_CarlosAnibalRodriguezSanudo.pdf: 7986861 bytes, checksum: ef729876c21927bbebee4642db4fd1da (MD5) / Este trabalho apresenta uma nova metodologia para a avaliação do desempenho funcional de instrumentos de medição de qualidade da energia elétrica. Trata-se de um procedimento que contempla os aspectos técnicos e metrológicos demandados pela IEC 61000-4-30 (2008), para cada um dos parâmetros de qualidade da energia, por meio do uso do ISO-GUM (2008). A IEC 61000-4-30 é uma diretriz que visa à padronização das medições dos parâmetros da qualidade da energia elétrica, indi- cando os métodos e as técnicas para a quanti cação dos mesmos. Já o ISO-GUM é um guia elaborado para a ciência da metrologia com a nalidade de estabelecer regras referentes à expressão da incerteza de medições para uso em padronização, calibração, acreditação de laboratórios e serviços metrológicos. Da junção destes conhecimentos, são propostos três tipos de testes que permitem a identi cação dos aspectos irregulares dos medidores considerando-se as exigências da IEC 61000-4- 30. Para garantir repetitividade nos resultados, a metodologia estruturou-se em três cadernos elaborados com os procedimentos para a execução dos mencionados testes. O produto é um relatório que expressa o desempenho do instrumento sob avalia- ção e torna possível a identi cação das aptidões e das de ciências dos instrumentos voltados à medição da qualidade da energia elétrica. São ainda expostos procedi- mentos laboratoriais, e um exemplo de aplicação da metodologia proposta sobre um medidor. ______________________________________________________________________________ ABSTRACT / This dissertation proposes a methodology to evaluate the operating performance of power quality measurement instruments. It entails a procedure which includes, for each power quality parameter, technical and metrological characteristics deman- ded by the IEC 61000-4-30 (2008), through use of the ISO-GUM (2008). The IEC 61000-4-30 provides measurement methods and sets accuracy levels for the power quality parameters. The main motivation for this standard is to provide common requirements for measurement devices to ensure that power quality meters from di erent manufacturers give the same results. The ISO-GUM is a guide that esta- blishes general rules for evaluating and expressing uncertainty in measurements that are intended to be applicable for standardization, calibration, laboratory accreditation and metrology services. Three types of tests to identify the irregular aspects of meters considering the requirements of the IEC 61000-4-30 are proposed from the joining of this standard and this guide. The methodology is structured into three notebooks with the procedures established for the implementation of the above tests to ensure repeatability of the results. The product is a report that expresses the performance of the instrument under evaluation and makes it possible to identify the qualities and shortcomings of instruments designed to measure power quality. Moreover, the laboratory results of employing the aforementioned methodology with the measuring equipment are put forth.
80

Análise de Sensibilidade de Parâmetros e de Desempenho do Modelo Soil And Water Assessment Tools (SWAT) na Estimativa de Vazões Médias em Bacias Hidrográficas

MOREIRA, L. L. 19 April 2017 (has links)
Made available in DSpace on 2018-08-01T23:57:59Z (GMT). No. of bitstreams: 1 tese_10941_Dissertação - Luana - Final versão final eletronica.pdf: 3676894 bytes, checksum: 1e394ab09ed35e7ff57b847a108f68d1 (MD5) Previous issue date: 2017-04-19 / A modelagem de vazões médias vem acompanhada de incertezas relacionadas aos dados de entrada climatológicos e às características fisiográficas da bacia hidrográfica. A obtenção de vazões representativas da área de estudo requer o ajuste destas com os dados observados. Uma calibração satisfatória depende de uma série de fatores que interferem neste processo. Dessa forma, avaliou-se a eficácia da calibração das vazões estimadas pelo modelo Soil and Water Assessment Tool (SWAT) em uma bacia hidrográfica rural localizada no sul do estado do Espírito Santo, variando os parâmetros de calibração, diferentes estações de monitoramento de vazões, tamanho da série histórica e o número de sub-bacias envolvidas no processo, além de verificar o processo de análise de sensibilidade dos parâmetros de calibração e a influência dos mesmos e dos dados de entrada na estimativa das vazões. Os resultados da análise de sensibilidade identificaram que a maioria dos parâmetros mais sensíveis da área de estudo são iguais aos encontrados nos trabalhos realizados no Brasil e na região sudeste do país. Além disso, houveram diferenças nos parâmetros encontrados para cada tipo de análise realizada. As vazões médias obtidas pelo SWAT foram superestimadas quando comparadas com os dados observados, por isso foi necessário a calibração e análise da influência dos dados de entrada nesses resultados. Os testes de calibração foram realizados pelo programa SWAT-CUP e a eficácia de cada teste foi avaliada estatisticamente pelo Coeficiente de Eficiência de Nash-Sutcliffe (COE), Tendência Percentual (PBIAS) e Erro Quadrado Médio (EQM). Os testes de calibração com série longa de dados observados (29 anos) de duas estações fluviométricas não geraram resultados satisfatórios, o melhor resultado consistiu em variar todos os parâmetros de calibração em todas as sub-bacias da área de estudo. Utilizou esse teste com uma série histórica de 3 anos, e então foi possível obter uma calibração satisfatória com valores de COE iguais a 0,53 e 0,50, PBIAS iguais a 6,60 e 20,70 e EQM iguais a 0,72 e 0,69 para cada estação fluviométrica. Verifica-se que o processo de calibração é um ajuste fino, por isso requer que os dados simulados não apresentem resultados muito discrepantes com relação aos observados.

Page generated in 0.0807 seconds