Spelling suggestions: "subject:"checker.""
1 |
Finite Element Analysis of Problems in Topology OptimizationRakshit, Abhik 02 September 2003 (has links)
No description available.
|
2 |
Efeito sinérgico do estado aquoso das folhas de Psidium guineense Swartz em associação com agentes antimicrobianos frente a cepas de Staphylococcus aureus multidroga resistentesFERNANDES, Tiago Gomes 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T16:32:54Z (GMT). No. of bitstreams: 2
arquivo7518_1.pdf: 861826 bytes, checksum: 507c6fdbc58a474bb054f53555243232 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar a atividade antimicrobiana do extrato aquoso de
Psidium guineense Swartz (Araçá-do-campo) e cinco agentes antimicrobianos (ampicilina,
amoxicilina/ácido clavulânico, cefoxtina, ciprofloxacina e meropenem, frente a doze cepas de
Staphylococcus aureus com fenótipo de resistência. Quatro cepas de S. aureus (LFBM 01,
LFBM 26, LFBM 28, LFBM 33) apresentaram resistência a todos os agentes antimicrobianos
testados e foram selecionadas para o estudo da interação entre o extrato aquoso de P.
guineense e agentes antimicrobianos, pelo método do tabuleiro de xaderz (checkerboard). Os
critérios utilizados para avaliar a atividade sinérgica foram definidos pelo índice fracional da
concentração inibitória (FICI). Todas as cepas de S. aureus foram suscetíveis ao P. guineense,
determinado pelo método de microdiluição. A combinação do extrato de P. guineense com os
agentes antimicrobianos resultou em uma redução de oito vezes no valor da CIM, e o índice
da concentração inibitória fracionada (FICI) variou de 0.125 0.5, sugerindo uma interação
sinérgica frente as cepas de S. aureus multidroga resistentes. A combinação do extrato
aquoso de P. guineense com cefoxitina apresentou os menores valores FICI. Este estudo
demonstrou que o extrato aquoso de P. guineense, quando associado aos agentes
antimicrobianos betalactâmicos, fluoroquinolonas e carbapenêmicos age sinergicamente,
inibindo cepas multirresistente de S. aureus
|
3 |
Comparação da contaminação microbiana de dois sistemas de encaixe para sobredentaduras mandibulares retidas por implantes. Estudo clínico randomizado / Microbial contamination comparison of two attachment systems for implant retained mandibular overdentures - randomized clinical trialPinheiro, Marília Lamenha Lins 30 May 2018 (has links)
A colonização e proliferação de micro-organismos periodontopatogênicos na gengiva marginal aos implantes dentários, assim como ao redor de seus componentes protéticos, pode representar riscos à saúde dos tecidos peri-implantares, à semelhança do que ocorre com os tecidos periodontais. O objetivo deste estudo foi identificar e quantificar 32 espécies microbianas de biofilmes coletados das superfícies de dois sistemas de encaixe para sobredentaduras retidas por implantes: um esférico (Retentive Anchor, Institut Straumann AG, Suíça - RA) e um cilíndrico (Locator, Zest Anchors Inc., CA-USA - Loc), das próteses, implantes e sulcos peri-implantares, ao longo do tempo. Os biofilmes analisados foram coletados em um estudo randomizado envolvendo 24 pacientes portadores de prótese total superior e sobredentadura inferior retida por dois implantes com sistemas de encaixe esférico RA (n= 12) ou cilíndrico Loc (n= 12). Amostras de biofilme foram coletadas de sete sítios para cada implante, nos períodos: após a instalação de novos encaixes (baseline), assim como aos 3 e 12 meses subsequentes. A identificação e quantificação das espécies microbianas foram realizadas por meio da técnica de hibridização DNA-DNA Checkerboard. Os resultados foram submetidos à análise não paramétrica de modelo misto ANOVAF, e matriz de covariância não estruturada para cada tratamento, com nível de significância de 0.05, posteriormente ajustado por Benjamini-Hochberg false discovery rate (FDR). Considerando-se todos os sítios e períodos investigados em conjunto e as 32 espécies bacterianas investigadas, apenas a S. constellatus foi encontrada em maior abundância nos biofilmes associados ao sistema RA. A análise sítio-específica revelou maior prevalência das espécies S. constellatus e P. micra na rosca do componente macho do encaixe esférico RA e da espécie S. sanguinis na superfície externa do componente macho do encaixe cilíndrico Loc. De modo geral, pôde-se concluir que os sistemas de encaixe para retenção de sobredentaduras RA e Loc são colonizados por microbiotas com perfis semelhantes, embora esses sistemas exerçam influência seletiva sobre o padrão de colonização das espécies bacterianas S. constelatus, P. micra e S. sanguinis / The colonization and proliferation of periodontopathogenic microorganisms in the dental implants marginal gingiva, as well as around their prosthetic components, may represent risks to the health of the peri-implant tissues, similar to what occurs with the periodontal tissues. The objective of this study was to identify and quantify 32 microbial species of biofilms collected from the surfaces of two attachment systems for implant retained mandibular overdentures: one spherical (Retentive Anchor, Institut Straumann AG, Switzerland - RA) and one cylindrical (Locator, Zest Anchors Inc., CA-USA - Loc), of prostheses, implants and peri-implant sulcus, over time. The biofilms analyzed were collected in a randomized study involving 24 patients with superior complete dentures and inferior overdenture retained by two implants with spherical attachment RA (n = 12) or cylindrical Loc (n = 12) systems. Biofilm samples were collected from seven sites of each implant, at the periods: after new attachments installation (baseline), as well at the next 3 and 12 months. The microbial species identification and quantification were carried out using DNA-DNA Checkerboard hybridization technique. The results were submitted to the mixed model non-parametric analysis \"ANOVAF\" and non-structured covariance matrix for each treatment, with 0.05 significance level, later adjusted by \"Benjamini-Hochberg\" false discovery rate (FDR). Considering all the sites and periods investigated together and the 32 bacterial species investigated, only S. constellatus was found in greater abundance in the biofilms associated to the RA system. The site-specific analysis revealed a higher prevalence of S. constellatus and P. micra species on the male component of the RA spherical attachment and of S. sanguinis species on the outer surface of the male component of the cylindrical Loc attachment. In general, it can be concluded that the overdenture attachment systems RA and Loc are colonized by microbiotas with similar profiles, although these systems exert a selective influence on the colonization pattern of S. constelatus, P. micra and S. sanguinis bacterial species
|
4 |
Avaliação da passagem de micro-organismos por meio da interface entre implantes e conectores protéticos com parafusos convencionais planos e experimentais cônicos pela técnica DNA-Checkerboard / Evaluation of microorganisms leakage through the interface between implants and prosthetic connectors with conventional plane and experimental conical screws by DNA-Checkerboard techniqueSantos, Carla Gabaldo Pessoa dos 03 March 2017 (has links)
Apesar da confiabilidade e da sobrevivência relacionadas aos tratamentos com implantes, falhas das reabilitações orais implanto-suportadas ainda são persistentes. Estas falhas podem causar tanto danos mecânicos -como o afrouxamento do parafuso de retenção devido à instabilidade das conexões- quanto danos biológicos -como as reações inflamatórias nos tecidos peri-implantares devido à ocorrência de infiltração bacteriana através da interface implante/pilar e a consequente colonização do interior dos implantes e seus componentes. Os mecanismos responsáveis por estas falhas mecânicas/biológicas dos sistemas de implantes não estão totalmente elucidados, e modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de aumentar a estabilidade das conexões e minimizar estas intercorrências. Entretanto, a literatura relativa à configuração ideal destas modificações e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, os objetivos do presente do estudo foram avaliar microbiologicamente por meio da técnica de hibridização DNA-Checkerboard, a ocorrência de infiltração bacteriana do meio externo para o interior dos implantes através das diferentes interfaces implante/pilar em dois diferentes sistemas de conexão de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos experimentais cônicos. Quarenta e oito implantes dos dois tipos de conexão foram analisados, sendo estes HE ( n = 24) ou TI (n = 24). Os pilares foram fixados a implantes com parafusos convencionais ou parafusos cônicos experimentais. Após a incubação em saliva, a hibridização DNA Checkerboard foi utilizada para identificar e quantificar até 38 espécies bacterianas na área interna dos implantes. Para análise estatística utilizou-se o teste de Kruskal-Wallis seguido de pós-testes de Bonferroni para comparações múltiplas. Vinte e quatro das trinta e oito espécies estudadas, incluindo patógenos putativos periodontais, foram encontradas colonizando as superfícies internas dos implantes HE e TI. Peptostreptococcus anaerobios (P = 0,003), Prevotella melaninogenica (P <0,0001) e Candida dubliniensis (P <0,0001) apresentaram diferenças significativas entre os diferentes grupos. As médias de contagem microbiana total (× 104, ± DP) para cada grupo foram registradas como: G1 (0,27 ± 2,04), G2 (0 ± 0), G3 (1,81 ± 7,50) e G4 (0,35 ± 1,81). As diferentes geometrias das conexões de implantes e parafusos apresentaram distintos níveis de penetração microbiana através da interface implante-pilar. Os implantes ligados com parafusos de pilar de cabeça cônica experimental apresentaram contagens menores de micro-organismos quando comparados com os parafusos convencionais. / Despite the reliability and high success rates related to treatment with implants, failures of implant-supported oral rehabilitation are still persistent. These failures can cause both mechanical damage, such as loosening the retaining screw connections due to instability, as biological damage, such as inflammatory reactions in periimplants tissues due to the occurrence of bacterial leakage along the implant/abutment interface and the subsequent colonization of the subsequent colonization of the internal/inner parts of the implants and components. The mechanisms responsible for these mechanical/biological failures of implant systems are not fully elucidated, and changes to the models of prosthetic connections and retaining screws have been developed in order to increase the stability of connections and minimize these problems. However, the literature related to these changes and its impact on the implant-components stability is still inconclusive. The objective of this study was to evaluate microbiologically by the DNA-Checkerboard hybridization, the occurrence of bacterial leakage from the external environment to the interior of the implant through these different implant/abutment interface. For the study will be evaluated two different implant connections, one external hexagonal (EH) and other internal triangle (IT), with either conventional and experimental tapered screws abutment. Forty-eight two-part implants with external hexagon (EH; n = 24) or tri-channel internal (TI; n = 24) connections were investigated. Abutments were attached to implants with conventional flat-head or experimental conical-head screws. After saliva incubation, Checkerboard DNA-DNA hybridization was used to identify and quantify up to 38 bacterial colonizing the internal parts of the implants. Kruskal-Wallis test followed by Bonferroni\'s post-tests for multiple comparisons was used for statistical analysis. Twenty-four of thirty-eight species, including putative periodontal pathogens, were found colonizing the inner surfaces of both EH and TI implants. Peptostreptococcus anaerobios (P = 0.003), Prevotella melaninogenica (P < 0.0001), and Candida dubliniensis (P < 0.0001) presented significant differences between different groups. Means of total microbial count (×104 , ±SD) for each group were recorded as follows: G1 (0.27 ± 2.04), G2 (0 ± 0), G3 (1.81 ± 7.50), and G4 (0.35 ± 1.81). Differences in the geometry of implant connections and abutment screws have impacted the microbial leakage through the implant-abutment interface. Implants attached with experimental conical-head abutment screws showed lower counts of microorganisms when compared with conventional flat-head screws.
|
5 |
Avaliação da infiltração bacteriana através da interface implante-conector protético sob aplicação de carga - avaliação in vitro pelo método DNA Checkerboard / Bacterial leakage along the implant-abutment interface after loading simulation. In vitro evaluation by DNA Checkerboard methodNascimento, Cássio do 03 September 2010 (has links)
A passagem bacteriana através da interface entre implante e conector protético com a conseqüente colonização dos implantes tem sido relatada em diversos estudos na literatura. O objetivo deste estudo in vitro foi avaliar a passagem de espécies bacterianas da saliva humana para o interior dos implantes através da interface implante-conector protético após simulação de carga cíclica controlada. Foram avaliados 60 implantes de um sistema de 2 componentes e seus respectivos conectores protéticos, divididos em 3 grupos de acordo com o tipo de conexão utilizado: hexágono externo, hexágono interno e cone morse. Cada grupo foi dividido em 2 subgrupos (n=10), submetidos à aplicação de carga e controle. Previamente ao teste, amostras do interior dos implantes foram coletadas para servirem como controle negativo da contaminação. Os conectores foram adaptados aos implantes com um torque final de 20 Ncm, de acordo com a recomendação do fabricante. Os conjuntos foram imersos em saliva humana e submetidos a 500.000 ciclos de carga com uma força de 120 N ou incubados em 35°C durante 7 dias sem aplicação de carga (controle). A eventual contaminação do interior dos implantes foi avaliada após o período experimental usando o método DNA Checkerboard. Microrganismos foram encontrados no interior dos implantes de todos os tipos de conexões avaliadas após o teste de carga cíclica. Os grupos cone morse apresentaram os menores valores de contagem bacteriana nos grupos submetidos a ciclagem de carga e controle. Os implantes submetidos à carga cíclica apresentaram maiores valores de contagem bacteriana do que seus respectivos controles no hexágono externo e interno. Nenhuma espécie bacteriana foi encontrada abrigando o interior dos implantes antes do teste de contaminação (controle negativo). Os implantes do grupo cone morse apresentaram menores quantidades de microrganismos nas duas condições testadas. Pode-se concluir que espécies bacterianas provenientes da saliva humana podem penetrar através da interface implante-conector protético com ou sem a simulação de carga cíclica, e que a aplicação de carga contribuiu para o aumento da contaminação nos implantes com conexão hexagonal externa e interna. / Bacterial leakage along the implant-abutment interface with consequent species harboring the inner parts of two-part dental implant systems has been reported. The aim of this in vitro study was to evaluate the bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loading conditions. Sixty dental implants, 20 for each external or internal hexagon and morse cone connection, and their conical abutments were used in this study. Each connection was sub-divided in 2 groups (n=10), loaded implants and control (unloaded). Previously to the bacterial leakage test, samples from the inner parts of the implants were collected with sterile microbrushes as negative control of contamination. The abutments were tightened to 20 Ncm on the implants. The assemblies were immersed in human saliva and loaded with 500,000 cycles of 120 N in experimental or incubated for 7 days at 35°C in control group. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all connections evaluated. Morse cone connection presented the lowest count of microorganisms in control and loading group. Loaded implants present higher counts of microorganisms than control group in external and internal hexagon. No microorganisms were found in the samples recovered from the implants before contamination test (negative control). It can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface under unloaded and loaded conditions, and morse cone connection presented the lowest count of microorganisms.
|
6 |
Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonizationCunha, Tatiana Ramirez 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (α=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (α=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
|
7 |
Avaliação da passagem de micro-organismos por meio da interface entre implantes e conectores protéticos com parafusos convencionais planos e experimentais cônicos pela técnica DNA-Checkerboard / Evaluation of microorganisms leakage through the interface between implants and prosthetic connectors with conventional plane and experimental conical screws by DNA-Checkerboard techniqueCarla Gabaldo Pessoa dos Santos 03 March 2017 (has links)
Apesar da confiabilidade e da sobrevivência relacionadas aos tratamentos com implantes, falhas das reabilitações orais implanto-suportadas ainda são persistentes. Estas falhas podem causar tanto danos mecânicos -como o afrouxamento do parafuso de retenção devido à instabilidade das conexões- quanto danos biológicos -como as reações inflamatórias nos tecidos peri-implantares devido à ocorrência de infiltração bacteriana através da interface implante/pilar e a consequente colonização do interior dos implantes e seus componentes. Os mecanismos responsáveis por estas falhas mecânicas/biológicas dos sistemas de implantes não estão totalmente elucidados, e modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de aumentar a estabilidade das conexões e minimizar estas intercorrências. Entretanto, a literatura relativa à configuração ideal destas modificações e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, os objetivos do presente do estudo foram avaliar microbiologicamente por meio da técnica de hibridização DNA-Checkerboard, a ocorrência de infiltração bacteriana do meio externo para o interior dos implantes através das diferentes interfaces implante/pilar em dois diferentes sistemas de conexão de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos experimentais cônicos. Quarenta e oito implantes dos dois tipos de conexão foram analisados, sendo estes HE ( n = 24) ou TI (n = 24). Os pilares foram fixados a implantes com parafusos convencionais ou parafusos cônicos experimentais. Após a incubação em saliva, a hibridização DNA Checkerboard foi utilizada para identificar e quantificar até 38 espécies bacterianas na área interna dos implantes. Para análise estatística utilizou-se o teste de Kruskal-Wallis seguido de pós-testes de Bonferroni para comparações múltiplas. Vinte e quatro das trinta e oito espécies estudadas, incluindo patógenos putativos periodontais, foram encontradas colonizando as superfícies internas dos implantes HE e TI. Peptostreptococcus anaerobios (P = 0,003), Prevotella melaninogenica (P <0,0001) e Candida dubliniensis (P <0,0001) apresentaram diferenças significativas entre os diferentes grupos. As médias de contagem microbiana total (× 104, ± DP) para cada grupo foram registradas como: G1 (0,27 ± 2,04), G2 (0 ± 0), G3 (1,81 ± 7,50) e G4 (0,35 ± 1,81). As diferentes geometrias das conexões de implantes e parafusos apresentaram distintos níveis de penetração microbiana através da interface implante-pilar. Os implantes ligados com parafusos de pilar de cabeça cônica experimental apresentaram contagens menores de micro-organismos quando comparados com os parafusos convencionais. / Despite the reliability and high success rates related to treatment with implants, failures of implant-supported oral rehabilitation are still persistent. These failures can cause both mechanical damage, such as loosening the retaining screw connections due to instability, as biological damage, such as inflammatory reactions in periimplants tissues due to the occurrence of bacterial leakage along the implant/abutment interface and the subsequent colonization of the subsequent colonization of the internal/inner parts of the implants and components. The mechanisms responsible for these mechanical/biological failures of implant systems are not fully elucidated, and changes to the models of prosthetic connections and retaining screws have been developed in order to increase the stability of connections and minimize these problems. However, the literature related to these changes and its impact on the implant-components stability is still inconclusive. The objective of this study was to evaluate microbiologically by the DNA-Checkerboard hybridization, the occurrence of bacterial leakage from the external environment to the interior of the implant through these different implant/abutment interface. For the study will be evaluated two different implant connections, one external hexagonal (EH) and other internal triangle (IT), with either conventional and experimental tapered screws abutment. Forty-eight two-part implants with external hexagon (EH; n = 24) or tri-channel internal (TI; n = 24) connections were investigated. Abutments were attached to implants with conventional flat-head or experimental conical-head screws. After saliva incubation, Checkerboard DNA-DNA hybridization was used to identify and quantify up to 38 bacterial colonizing the internal parts of the implants. Kruskal-Wallis test followed by Bonferroni\'s post-tests for multiple comparisons was used for statistical analysis. Twenty-four of thirty-eight species, including putative periodontal pathogens, were found colonizing the inner surfaces of both EH and TI implants. Peptostreptococcus anaerobios (P = 0.003), Prevotella melaninogenica (P < 0.0001), and Candida dubliniensis (P < 0.0001) presented significant differences between different groups. Means of total microbial count (×104 , ±SD) for each group were recorded as follows: G1 (0.27 ± 2.04), G2 (0 ± 0), G3 (1.81 ± 7.50), and G4 (0.35 ± 1.81). Differences in the geometry of implant connections and abutment screws have impacted the microbial leakage through the implant-abutment interface. Implants attached with experimental conical-head abutment screws showed lower counts of microorganisms when compared with conventional flat-head screws.
|
8 |
Avaliação da infiltração bacteriana através da interface implante-conector protético sob aplicação de carga - avaliação in vitro pelo método DNA Checkerboard / Bacterial leakage along the implant-abutment interface after loading simulation. In vitro evaluation by DNA Checkerboard methodCássio do Nascimento 03 September 2010 (has links)
A passagem bacteriana através da interface entre implante e conector protético com a conseqüente colonização dos implantes tem sido relatada em diversos estudos na literatura. O objetivo deste estudo in vitro foi avaliar a passagem de espécies bacterianas da saliva humana para o interior dos implantes através da interface implante-conector protético após simulação de carga cíclica controlada. Foram avaliados 60 implantes de um sistema de 2 componentes e seus respectivos conectores protéticos, divididos em 3 grupos de acordo com o tipo de conexão utilizado: hexágono externo, hexágono interno e cone morse. Cada grupo foi dividido em 2 subgrupos (n=10), submetidos à aplicação de carga e controle. Previamente ao teste, amostras do interior dos implantes foram coletadas para servirem como controle negativo da contaminação. Os conectores foram adaptados aos implantes com um torque final de 20 Ncm, de acordo com a recomendação do fabricante. Os conjuntos foram imersos em saliva humana e submetidos a 500.000 ciclos de carga com uma força de 120 N ou incubados em 35°C durante 7 dias sem aplicação de carga (controle). A eventual contaminação do interior dos implantes foi avaliada após o período experimental usando o método DNA Checkerboard. Microrganismos foram encontrados no interior dos implantes de todos os tipos de conexões avaliadas após o teste de carga cíclica. Os grupos cone morse apresentaram os menores valores de contagem bacteriana nos grupos submetidos a ciclagem de carga e controle. Os implantes submetidos à carga cíclica apresentaram maiores valores de contagem bacteriana do que seus respectivos controles no hexágono externo e interno. Nenhuma espécie bacteriana foi encontrada abrigando o interior dos implantes antes do teste de contaminação (controle negativo). Os implantes do grupo cone morse apresentaram menores quantidades de microrganismos nas duas condições testadas. Pode-se concluir que espécies bacterianas provenientes da saliva humana podem penetrar através da interface implante-conector protético com ou sem a simulação de carga cíclica, e que a aplicação de carga contribuiu para o aumento da contaminação nos implantes com conexão hexagonal externa e interna. / Bacterial leakage along the implant-abutment interface with consequent species harboring the inner parts of two-part dental implant systems has been reported. The aim of this in vitro study was to evaluate the bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loading conditions. Sixty dental implants, 20 for each external or internal hexagon and morse cone connection, and their conical abutments were used in this study. Each connection was sub-divided in 2 groups (n=10), loaded implants and control (unloaded). Previously to the bacterial leakage test, samples from the inner parts of the implants were collected with sterile microbrushes as negative control of contamination. The abutments were tightened to 20 Ncm on the implants. The assemblies were immersed in human saliva and loaded with 500,000 cycles of 120 N in experimental or incubated for 7 days at 35°C in control group. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all connections evaluated. Morse cone connection presented the lowest count of microorganisms in control and loading group. Loaded implants present higher counts of microorganisms than control group in external and internal hexagon. No microorganisms were found in the samples recovered from the implants before contamination test (negative control). It can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface under unloaded and loaded conditions, and morse cone connection presented the lowest count of microorganisms.
|
9 |
Overdentures mandibulares retidas por mini-implantes ou implantes convecionais: avaliação da função mastigatória e colonização microbiana / Mandibular overdentures retained by mini or conventional implants: assessment of masticatory function and microbial colonizationTatiana Ramirez Cunha 09 June 2015 (has links)
Implantes de diâmetro reduzido, ou mini-implantes, têm sido recentemente considerados para a retenção e suporte de overdentures mandibulares em pacientes totalmente desdentados. No entanto, pouco se sabe sobre o desempenho da função mastigatória com esse tipo de tratamento e da microbiota associada aos mini-implantes. Portanto, estudos clínicos que validem o tratamento com mini-implantes e overdentures são necessários. Assim, os objetivos deste estudo foram: 1) avaliar a habilidade e performance mastigatórias de indivíduos portadores de overdentures mandibulares retidas por quatro ou dois mini-implantes (grupos I e II, respectivamente) ou dois implantes convencionais (grupo III); 2) comparar a performance mastigatória destes indivíduos com a encontrada em portadores de próteses totais convencionais (grupo IV comparador externo); e 3) comparar qualitativa e quantitativamente a microbiota peri-implantar de mini-implantes e de implantes convencionais. Participaram deste estudo 60 indivíduos portadores de overdentures mandibulares (20 de cada grupo) e 20 portadores de próteses totais convencionais. Três meses após a instalação das overdentures mandibulares (grupos I, II e III), a habilidade mastigatória (HM) foi avaliada por meio de um questionário desenvolvido para esta finalidade. A performance mastigatória (PM) dos participantes foi avaliada seis meses após a instalação das overdentures por meio de um método que determina a alteração de cor de uma goma de mascar utilizada como alimento teste. A microbiota do sulco peri-implantar dos mini-implantes do grupo II e dos implantes convencionais (grupo III) foi identificada e quantificada pelo método DNA Checkerboard (38 espécies de microrganismos avaliadas) em dois momentos: T0 (primeira coleta), realizada 3 meses após a exposição dos implantes à cavidade oral, e T1 (segunda coleta), seis meses após a primeira coleta. Os grupos foram comparados por meio de testes adequados à distribuição dos dados (α=5%). Embora a HM tenha sido semelhante entre os grupos I, II e III, a dificuldade em mastigar alimentos moles associada à overdenture foi maior para o grupo III (Kruskal-Wallis, p=0,041). A PM também foi similar nos grupos I, II e III, mas significantemente maior do que a do grupo IV (Tukey, p<0,05). As 38 espécies alvo do estudo foram detectadas nos dois tipos de implantes em T0 e T1, com exceção da espécie E. faecalis nos implantes convencionais em T1. Houve uma diminuição significante na quantidade total de bactérias e fungos no grupo II e aumento no grupo III (Wilcoxon Pareado, p<0,05) no período analisado. A quantidade total de microrganismos no grupo III foi significantemente maior do que no grupo II em T1 (Mann-Whitney; p<0,05), sendo que mais de 70% das espécies avaliadas estavam presentes em maior quantidade no grupo III (Mann-Whitney; p<0,05). Levando-se em conta as limitações deste estudo, pode-se concluir que overdentures mandibulares retidas por quatro ou dois mini-implantes são tão efetivas quanto aquelas retidas por dois implantes convencionais quanto a habilidade e performance mastigatórias, e que este tipo de reabilitação promove uma performance mastigatória superior à encontrada em portadores de próteses totais convencionais. Além disso, a microbiota do sulco peri-implantar de mini-implantes é quantitativamente inferior e qualitativamente semelhante à microbiota associada a implantes convencionais quando utilizados para reter/suportar overdentures mandibulares. / Narrow diameter implants, or mini dental implants, have recently been considered to retain and to support mandibular and maxillary overdentures in completely edentulous subjects. However, there is scant information about the performance of masticatory function with this type of treatment and the microbiota associated with mini-implants. Therefore, clinical trials to valid the treatment with mini implants and overdentures are necessary. Thus, this study aimed to: 1) assess the ability and masticatory performance in mandibular overdenture wearers after the insertion of four or two mini implants (group I and II, respectively) or two standard-size implants (group III); 2) compare their masticatory performance with that obtained by complete denture wearers (group IV external comparison); 3) compare qualitatively and quantitatively the peri-implant microbiota of mini and standard-size implants. Sixty mandibular overdenture wearers (20 per group) and 20 complete denture wearers participated in the study. Three months after the insertion of the mandibular overdentures (group I, II and III) the masticatory ability (MA) was assessed by a questionnaire developed for this purpose. The masticatory performance (MP) was assessed six months after the insertion of the overdentures by a test using a color-changeable chewing gum. The peri-implant microbiota of mini (group II) and standard-size implants (group III) was identified and quantified by DNA Checkerboard method (38 microorganisms species assessed) in two times: T0 (first collect) three months after the implants exposure to the oral cavity, and T1 (second collect) six months after T0. The groups were compared by tests according to data distribution (α=5%). Although the MA was similar between the assessed groups (I, II and III), the difficult to chew soft foods caused by the overdenture was higher for group III (Kruskal-Wallis, p=0,041). The MP was similar between groups I, II and III. However, it was higher than the MP in group IV (Tukey, p<0,05). All the 38 species were detected in the two implants in T0 and T1, except the E. faecalis in group III in T1. There was a significant decrease in the total amount of bacteria and fungi in group II and increase in group III (Wilcoxon Pareado; p<0,05) during the period analysed. The total amount of microorganisms in group III was higher than in group II in T1 (Mann-Whitney; p<0,05), with over than 70% of the species identified in larger amount in group III (Mann-Whitney; p<0,05). Taking into account the limitations of this study, it was concluded that the mandibular overdentures retained by four or two mini implants are as effective as those retained by two standard-size implants considering the masticatory ability and performance. Moreover, these treatments promote higher masticatory performance than that found in conventional dentures wearers. In addition, the peri-implant microbiota of mini implants is quantitatively lower and qualitatively similar to the microbiota associated with standard-size implants used to retain overdentures.
|
10 |
Verification of the "Energy Accumulation in Waves Travelling through a Checkerboard Dielectric Material Structure in Space-time" Using Spice SimulationsSamant, Gajanan Balkrishna 22 December 2009 (has links)
"Recently, there has been some good interest in the field of Dynamic Materials, also referred to as Spatio-Temporal Composites. These materials have been theoretically attributed to show ability to switch their electromagnetic properties in time, as contrast to the spatial variations shown by regular materials of non-dynamic nature, existing naturally. Though there is no exhibition of dynamic material in nature yet, there are suggestions for its synthesis. This paper follows the idea of using standard lossless transmission line model approximating a material substance. Such a material though not truly homogeneous, could be made to vary its properties in time. The aim of this work is to test this idea for its functional efficiency in comparison to analytical results obtained from earlier works on the subject. We make use of Spice simulation for this. An important aspect of this work is to facilitate the dynamic operations in a static environment. Almost all the simulators available today like Spice, ADS, etc intrinsically provide no ability for parameter variations in time. Nonetheless, we make use of certain popular tricks to implement circuits imitating the dynamic circuit components we need. Such implementations are separately tested to demonstrate their success in providing us with the dynamic environment we desire. Finally, within the limitations of the computing capabilities, we could successfully show an agreement between the results obtained and the existing theory. "
|
Page generated in 0.061 seconds