• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 48
  • Tagged with
  • 48
  • 48
  • 28
  • 22
  • 16
  • 13
  • 13
  • 13
  • 13
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo clínico comparativo entre diferentes sistemas de clareamento de uso em consultório / Comparative clinical trial between different in-office bleaching systems

Flávio Henrique Umeda Gentil 22 October 2015 (has links)
Objetivos: Estudos clínicos longitudinais que acompanham os pacientes por longos períodos não são muito comuns na literatura, ainda mais quando associados a grandes amostras (veio do fim do resumo). Por isso, o objetivo do trabalho foi determinar a eficiência, estabilidade de cor e sensibilidade dental, trans e pós operatória, dentro de um período de 365 dias, de quatro protocolos de clareamento em consultório. Material e Métodos: Foi realizado um estudo clínico randomizado, cego (para os pacientes), composto por 120 sujeitos (n=30). A amostra foi formada por pacientes adultos, sem distinção de gênero e etnia, e idade superior a 18 anos que foram selecionados por meio de avaliação clínica na qual foi verificada a cor dos dentes, a condição de higiene oral e a presença de restaurações e/ou próteses nas regiões em que os procedimentos seriam realizados. Todos os sujeitos foram submetidos a uma sessão de clareamento de acordo com as instruções do fabricante e obedecendo a aplicação ou não da luz, para os clareadores baseados no sistema Foto-Fenton (havia faltado citar nos métodos do resumo), e qual o seu tipo: Zoom Advanced Power, peróxido de hidrogênio (PH) 25% - Zoom! + luz UVA (Phillips Oral Healthcare); Zoom Whitespeed, PH 25% - Zoom! + luz Whitespeed (Phillips Oral Healthcare); Zoom sem luz, PH 25% - Zoom! (Phillips Oral Healthcare). Boost, PH 38% - Opalescence Xtra Boost (Ultradent). As alterações de cor foram avaliadas utilizando as escalas Vita Classical e Vita Bleachedguide 3D Master e o Espectrofotômetro Vita-Easyshade. As medições foram feitas em incisivos centrais e caninos uperiores antes, imediatamente e 7, 14, 30, 180 e 365 dias após o tratamento. Os dados foram analisados estatisticamente por meio do software Statistica 8.0 (StatSoft - Tulsa, OK) através da análise de variância (ANOVA) para medidas repetidas na avaliação das médias e as comparações foram realizadas através de contrastes (Tukey). Resultados: Para a escala Vita Classical, Zoom AP e WS foram semelhantes entre si porém diferentes de Opalescence e Zoom sem luz, exceto para a avaliação de 30 dias (caninos) e 365 dias (incisivos) onde o Zoom WS demonstrou dados semelhantes ao Opalescence e Zoom sem luz Já para a escala Vita Bleached, Zoom AP e WS foram semelhantes entre si, porém diferentes de Opalescence e Zoom sem luz, exceto para as avaliações de 30 e 180 dias onde o Zoom WS demonstrou dados semelhantes ao Opalescence e Zoom sem luz (caninos). Para dentes incisivos, os achados foram semelhantes, exceto que houve diferença entre o Zoom AP e WS e as semelhanças entre Zoom WS, Opalescence e Zoom sem luz foram encontradas nas avaliações de 180 e 365 dias. Na avalição com o espectrofotômetro Vita Easyshade Zoom AP e WS foram semelhantes entre si e diferentes do Opalescence que, por sua vez, foi diferente do Zoom sem luz, exceto para as avaliações de 7, 14 e 30 dias (caninos). Para incisivos, Zoom AP e WS foram semelhantes entre si e diferentes de Opalescence e Zoom sem luz, exceto para a avaliação de 14 dias onde o Zoom AP foi diferente do Zoom WS. Por fim, a sensibilidade apresentou um aumento nos seus valores na avaliação imediatamente após o clareamento, com uma redução na avalição de 7 dias, para todos os grupos que ainda apresentaram valores de sensibilidade semelhantes em todos os períodos de avaliação. Conclusão: O acompanhamento até 365 dias demonstrou a eficiência dos protocolos de clareamento analisados uma vez que nenhum deles recidivou para os tons iniciais, demonstrando a durabilidade dos procedimentos. Os dois grupos com os clareadores Foto-Fenton obtiveram maior efeito clareador (substituiu desempenho, tinha ficado vago), exceto nas seguintes avaliações: Vita Classical, 30 dias (caninos) e 365 dias (incisivos) e Vita Bleached, 30 e 180 dias (caninos) e 180 e 365 dias (incisivos). Observou-se uma estabilização da cor após sete dias em todos os grupos. A sensibilidade pós operatória foi mais intensa nos primeiros 7 dias e nenhum paciente relatou sensibilidade a partir da avaliação de 14 dias. / Objectives: Longitudinal clinical studies that follow patients for long periods are not very common in the literature, especially when associated with large samples. The objective of this study was to determinate the efficacy, color stability and sensitivity within a 365 day period of four in-office bleaching protocols. Methods: A randomized clinical trial, blinded (for patients), composed of 120 subjects (n=30) was conducted. The sample consisted of adult patients, without gender and ethnic distinction, with age superior than 18 years old that were selected through clinical evaluation in which was verified the color of teeth, the condition of oral hygiene and the presence of restorations and/or prostheses in the areas where the procedures would be carried out. All subjects were submitted to a session of bleaching according to the manufacturer\'s instructions: Zoom Advanced Power, 25% hydrogen peroxide (HP) - Zoom! + UVA light (Phillips Oral Healthcare); Zoom Whitespeed, 25% HP - Zoom! + Whitespeed light (Phillips Oral Healthcare); Zoom without light, 25% HP - Zoom! (Phillips Oral Healthcare). Boost, 38% HP - Opalescence Xtra Boost (Ultradent). Color changes were evaluated using Vita Classical and Vita Bleachedguide 3D Master shade guides and Vita-Easyshade spectrophotometer. Measurements were made on the superior central incisive and canines before, immediately and 7, 14, 30, 180 and 365 days after the treatment. Statistical analysis of the data were made with the software Statistica 8.0 (StatSoft - Tulsa, OK) through the analysis of variance (ANOVA) for repeated measures in the mean evaluation and comparisons were made by using contrasts (Tukey). Results: For the Vita Classical shade guide, Zoom AP and WS were similar but different from Opalescence and Zoom without light except for the 30 day (canines) and 365 days evaluations (incisives) where the Zoom WS showed similar data to Opalescence and Zoom without light. As for the Vita Bleached shade guide, Zoom AP and WS were similar, but different from Opalescence and Zoom without light, except for the 30 and 180 days evaluation where Zoom WS showed similar data to Opalescence and Zoom without light (canines). For incisives, the findings were similar, except that there were differences between Zoom AP and WS and the similarities between Zoom WS, Opalescence and Zoom without light were found in the 180 and 365 days evaluations. For the evaluation with Vita Easyshade spectrophotometer, Zoom AP and WS were similar and different from Opalescence which was different from Zoom without light, except for the 7, 14 and 30 days evaluation (canines). For incisives, Zoom AP and WS were similar and different from Opalescence and Zoom without light, except for the 14 days evaluation where Zoom AP was different from Zoom WS. Finally, the sensitivity showed an increase in their values for the immediately after bleaching evaluation, with a reduction in the 7 days evaluation for all groups that still had similar sensitivity values in all evaluation periods. Conclusion: The follow-up to 365 days demonstrated the efficiency of the analyzed bleaching protocols since none relapsed to the initial shades, demonstrating the durability of the procedures. The two groups with the Photo-Fenton bleaching systems performed better, except for the following evaluations: Vita Classical, 30 days (canines) and 365 days (incisives) and Vita Bleached, 30 and 180 days (canines) and 180 and 365 days (incisives). There was a color stabilization after seven days in all groups. Postoperative sensitivity was more intense in the first 7 days and no patient reported sensitivity since the 14 days evaluation.
42

Efeitos de agentes clareadores externos nos tecidos dentários e na junção amelocementária / Effects of external bleaching agents on dental tissues and the cementoenamel junction

Oliveira, Milene de 30 January 2009 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-05T15:13:37Z No. of bitstreams: 1 milenedeoliveira.pdf: 7328157 bytes, checksum: f3b85a9b5ae8ef6aa51d4052e03db2d2 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-10-06T12:30:05Z (GMT) No. of bitstreams: 1 milenedeoliveira.pdf: 7328157 bytes, checksum: f3b85a9b5ae8ef6aa51d4052e03db2d2 (MD5) / Made available in DSpace on 2016-10-06T12:30:05Z (GMT). No. of bitstreams: 1 milenedeoliveira.pdf: 7328157 bytes, checksum: f3b85a9b5ae8ef6aa51d4052e03db2d2 (MD5) Previous issue date: 2009-01-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo foi avaliar, em microscopia eletrônica de varredura (MEV), as alterações ocorrentes no esmalte, no cemento e na junção amelocementária após o uso de diferentes agentes clareadores externos utilizados na técnica caseira e de consultório. Quinze pré-molares hígidos foram seccionados ao meio com o auxilio de uma máquina de corte (Labcut 1010), no sentido longitudinal do longo eixo dos dentes, obtendo-se faces mesiais e distais de cada dente. As faces mesiais foram divididas em três grupos de acordo com o material utilizado (AI- peróxido de carbamida 10% - Whiteness Standart 10 FGM®, AII - peróxido de carbamida 16% Whiteness Standart 16 FGM®, e AIII - peróxido de hidrogênio 35% Whiteness HP Maxx FGM®), seguindo as orientações do fabricante. As faces distais de cada dente foram mantidas em saliva artificial, em estufa bacteriológica a 37ºC. Após a clareação os espécimes foram desidratados em soluções crescentes de acetona e metalizados para avaliação em MEV. Os resultados foram submetidos à avaliação estatística pelos testes de Kruskall-Wallis e Mann-Whitney. Diferenças estatisticamente significativas foram observadas entre os espécimes clareados e os não clareados (p<0,001). Em esmalte, alterações insignificantes foram observadas, não havendo diferenças entre os grupos. Perda de estrutura, com formação de gaps e exposição dentinária foram observadas na junção amelocementária dos três grupos clareados, sendo mais acentuada no grupo A3. Maior perda de estrutura em cemento também foi observada no grupo A3. Pode-se concluir que o clareamento dental deve ser realizado com cautela pelo Cirurgião-Dentista, principalmente em pacientes que possuem recessão gengival. / Evaluate with a scanning electron microscope the alterations occurring in enamel, cementum and cementoenamel junction after the use of different external bleaching agents. Fifteen healthy pre-molars were sectioned in the middle with the aid of a cutting machine (Labcut 1010), in the longitudinal direction along the axis of the teeth, obtaining mesial and distal surfaces of each tooth. The mesial surfaces were divided into three groups in accord with the material used (AI- carbamide peroxide 10% - Whiteness Standard 10 FGM®, AII - carbamide peroxide 16% Whiteness Standard 16 FGM®, e AIII - hydrogen peroxide 35% Whiteness HP Maxx FGM®), according to the instructions of the manufacturers. The distal surfaces of each tooth were maintained in artificial saliva, in a bacteriological sterilizer at 37ºC. After whitening the specimens were dehydrated in increasing solutions of acetone and metalized for evaluation using the scanning electron microscope. The results were submitted to statistical evaluation using the Kruskall-Wallis and Mann-Whitey tests. Statistically significant differences were observed between the whitened and unwhitened specimens (p<0.001). In enamel, insignificant alterations were observed, there being no differences between the groups. Loss of structure, with formation of gaps and dental exposure were observed in the cementoenamel junction of the three whitened groups. Being more accented in group A3. It can be concluded that tooth whitening should be done with caution by the dental surgeon, principally in patients who possess gingival recession.
43

Avaliação do desgaste superficial do esmalte e da dentina radicular submetidos ao tratamento clareador: in vitro e in situ / Evaluation of enamel and root dentin surface wear submitted to bleaching treatment: in vitro and in situ

Romano, Juliana Jendiroba Faraoni 16 May 2008 (has links)
Devido a alterações químico-estruturais causadas pelo clareamento, os substratos dentais poderiam tornar-se mais susceptíveis a perda tecidual, principalmente se expostos a desafios erosivo/abrasivos. Desta forma, o presente estudo teve como objetivos: 1) analisar in vitro, se o esmalte e a radicular dentina clareada com diferentes agentes e concentrações, apresenta uma maior susceptibilidade ao desgaste, quando submetido a ciclos de erosão e abrasão; 2) comparar o efeito da aplicação de um agente clareador a base de peróxido de carbamida a 10% a um placebo no desgaste do esmalte e da dentina radicular, através de um modelo in situ. Os resultados do estudo in vitro mostraram que, independentemente do agente usado, o clareamento não aumentou o desgaste do esmalte frente a episódios erosivo-abrasivos. Na dentina, o desgaste foi dependente do agente clareador aplicado. Baseado no protocolo in situ adotado, o peróxido de carbamida a 10% não causou maior desgaste superficial no esmalte, mas aumentou a perda de tecido dentinário comparado ao placebo. Pode-se concluir que, em termos de desgaste superficial, o esmalte não foi afetado pelo tratamento clareador, enquanto a dentina mostrou-se mais susceptível. Assim, sugerem-se cuidados adicionais na seleção do agente clareador em situações clínicas que apresentam dentina radicular exposta. / Due to the chemical and microstructural alterations caused by bleaching, the dental substrates can become more susceptible to tissue loss, mainly if exposed to erosive/abrasive challenges. Therefore, the present study had the following objectives: 1) to analyze in vitro, if enamel and root dentin that had been bleached with different agents and concentrations, were at increased risk of wear when submitted to cycles of erosion and abrasion; 2) to compare the effect of the application of a 10% carbamide peroxide bleaching agent to a placebo on wear of enamel and root dentin, through an in situ model. The results of the in vitro study showed that independent of agent used, the bleaching demonstrated no increase in the wear of enamel when exposed to the erosive-abrasive episodes. In dentin, the wear was dependent on the bleaching agent applied. Based on the in situ protocol adopted, the 10% carbamide peroxide did not cause higher wear on the enamel, but increased the wear of the root dentin compared to the placebo. It could be concluded that in terms of superficial wear, enamel was not affected by bleaching treatment, while dentin showed to be more susceptible. Thus, additional caution is suggested in the choice of the bleaching agent when root dentin is exposed.
44

Influência do tipo de polimento pós-clareamento na alteração de rugosidade, cor e brilho da superfície de esmalte dental humano / Different polishing procedures influence in roughness, color and gloss of bleached human dental enamel surface

Freitas, Ana Carolina Pedreira de 05 November 2010 (has links)
O tratamento clareador pode resultar em alterações na rugosidade superficial do esmalte dental, as quais podem ser vistas a olho nu como alterações de cor, opacidade e perda de brilho. O objetivo deste estudo foi analisar in vitro a alteração de rugosidade, cor e brilho de superfícies de esmalte dental humano após clareamento com um produto a base de peróxido de hidrogênio (PH) 38% e após polimento com fluoreto de sódio 2% neutro (FS2%) ou pasta dentifrícia contendo partículas de nano-hidroxiapatita. Para isso, coroas de incisivos centrais humanos foram preparadas e tiveram suas faces vestibulares analisadas em microscópio de força atômica (MFA), o qual determinou os valores de rugosidade [Ra, RMS, Z range e Power Spectral Density (PSD)] iniciais. A cor e o brilho destas amostras foram determinados por um espectrofotômetro. Todas as amostras foram clareadas com PH 38% por 135 minutos. Os valores de Ra, RMS, Z range e PSD foram estabelecidos pelo MFA e a cor e o brilho determinados pelo espectrofotômetro. As amostras foram divididas em dois grupos: Flúor, que recebeu um polimento com gel de FS2%; e nHA, que recebeu um polimento com pasta dentifrícia contendo partículas de nano-hidroxiapatita. Os valores de Ra, RMS, Z range, PSD, cor e brilho pós-polimento foram determinados pelo MFA e espectrofotômetro. Após o clareamento, os valores de Ra, RMS, Z range e PSD não apresentaram alteração estatisticamente significante, os valores de L* aumentaram e C* diminuiu significativamente em todas as amostras. O brilho superficial não apresentou alteração significativa após o clareamento. O grupo Flúor não apresentou alteração de rugosidade significativa para Ra, RMS, Z range e PSD após o polimento. Os valores de L*, C* e brilho superficial também não apresentaram alterações significativas após o polimento das superfícies clareadas. No grupo nHA, os valores de Ra e RMS não apresentaram alteração significativa após o polimento das superfícies clareadas, porém os valores de Z range e PSD apresentaram alteração estatisticamente significante. Em comparação à superfície clareada, L* e C* não apresentaram alteração significante após o polimento, porém o brilho superficial foi significativamente maior. O tratamento clareador de consultório mostrou ser eficiente quanto à alteração de cor e não gerou aumento na rugosidade superficial do esmalte dental. Um polimento com pasta dentifrícia contendo partículas de nano-hidroxiapatita realizado após o clareamento é capaz de aumentar o brilho e diminuir a rugosidade superficial do esmalte dental. / Bleaching treatment may result in dental enamel surface roughness alterations, which might be seen as color alterations, opacity and gloss loss. The aim of this research was to in vitro investigate roughness, color and gloss alterations of human dental enamel surfaces after bleaching treatment with 38% hydrogen peroxide (HP) and after polishing with neutral 2% sodium fluoride or dental tooth paste containing nano-hydroxiapatite particles. Human central incisors were prepared and buccal surfaces were analyzed by an atomic force microscope (AFM), which determined roughness values [Ra, RMS, Z range and Power Spectral Density (PSD)]. Surface color and gloss were determined by a spectrophotometer. All samples were bleached with 38% HP for 135 minutes. AFM determined Ra, RMS, Z range and PSD after bleaching. Color and gloss were determined by the spectrophotometer. Samples were distributed in two different groups: Fluor, which was polished with neutral 2% sodium fluoride, and nHA, which was polished with dental tooth paste containing nano-hydroxyapatite particles. Ra, RMS, Z range, PSD, color and gloss values were determined by AFM and spectrophotometer after polishing. After bleaching, Ra, RMS, Z range and PSD didnt show any statistical difference. L* increased and C* decreased significantly in all samples after bleaching. Surface gloss didnt show significant alteration after bleaching. Fluor group didnt show surface roughness alteration considering Ra, RMS, Z range and PSD after polishing. L*, C* and gloss didnt change after bleached surfaces are polished with neutral 2% sodium fluoride. Ra and RMS of nHA group didnt change significantly after polishing, but Z range and PSD showed significant alteration. Despite L* and C* didnt change, gloss increased significantly after polishing with dental tooth paste containing nano-hydroxyapatite. In-office bleaching treatment showed to be efficient as for color enhancement and didnt cause roughness alteration in dental enamel surface. An after-bleaching polishing with dental tooth paste containing nano-hydroxyapatite particles may increase gloss and decrease surface roughness of dental enamel.
45

AVALIAÇÃO CLÍNICA DA INFLUÊNCIA DO CAFÉ NA EFETIVIDADE DO CLAREAMENTO DENTAL / Clinical evaluation of the influence of coffee in the effectiveness of dental bleaching

Siqueira, Márcia Fernanda de Rezende 29 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:19Z (GMT). No. of bitstreams: 1 MARCIA FERNANDA DE REZENDE SIQUEIRA.pdf: 1854900 bytes, checksum: 25353ada2c457db2da3208c5e6d94257 (MD5) Previous issue date: 2012-02-29 / The objective of this clinical study was to evaluate whether exposure to coffee during the bleaching treatment with PC 16 (Whiteness Perfect, FGM,Joinville, Santa Catarina, Brazil) affects the degree of whitening and tooth sensitivity. We selected 40 patients with central incisors darker than A2, which were divided into 2 groups (n=20): GC - control group and GE - the experimental group. For the CG was no restriction of foods with dyes and the GE patients beyond the usual coffee intake in his diet made with black coffee rinses soluble Nescafé® Tradição (Nestlé), 4 times daily for 30 seconds. For both groups we used PC 16 for a period of 3 hours daily for 3 weeks. The color scale was assessed by spectrophotometer Easyshade and in the periods: initial, during the whitening (1 st, 2 nd and 3 rd week) and postbleaching (1 week and 1 month). Patients recorded their perceptions of sensitivity through the NRS scale (0-4) and VAS. For the color analysis was performed analysis of variance (ANOVA) with repeated measures on two factors (time vs. treatment groups), time being the repeated measure (=0.05). We carried out the Tukey test for contrast of means (=0.05). The tooth sensitivity was evaluated by Fisher's exact test and the intensity of tooth sensitivity was evaluated by Mann-Whitney test (=0.05) for both scales. There effectiveness of tooth whitening over time (p <0.001). For both groups was not statistical differences in absolute risk of sensitivity between the groups (p=1.0). Most patients had mild tooth sensitivity and no statistically significant difference was detected between groups for both the NRS scale (p=0.529) and for the VAS (p=0.258). It was concluded that dental bleaching is effective for the groups studied, which makes possible the consumption of coffee during the bleaching treatment. / O objetivo deste estudo clínico foi avaliar se a exposição ao café durante o tratamento clareador com PC 16% (Whiteness Perfect, FGM, Joinville, Santa Catarina, Brasil) afeta o grau de clareamento e a sensibilidade dental. Foram selecionados 40 pacientes com os incisivos centrais mais escuros que A2, os quais foram divididos em 2 grupos (n=20): GC - grupo controle e GE - grupo experimental. Para o GC houve restrição de alimentos com corantes e para o GE os pacientes, além da ingestão usual do café na sua dieta, realizaram bochecho com café preto solúvel Nescafé Tradição (Nestlé) 4 vezes ao dia, por 30 segundos. Para os dois grupos utilizou-se PC 16% pelo período de 3h diariamente, durante 3 semanas. A cor foi avaliada através da escala Vita Classical e espectrofotômetro Vita Easyshade, nos períodos: inicial, durante o clareamento dental (1ª, 2ª e 3ª semanas) e pós-clareamento (1 semana e 1 mês). Os pacientes registraram suas percepções de sensibilidade através da escala NRS (0-4) e VAS. Para a análise de cor foi efetuada ANOVA de dois fatores (grupos vs tempo de tratamento), sendo o tempo a medida repetida (=0,05). Foi realizado o teste de Tukey para o contraste das médias =0,05). A sensibilidade dental foi avaliada pelo teste exato de Fisher e a intensidade da sensibilidade dental foi avaliada pelo teste Mann-Whitney (=0,05) para ambas as escalas. Houve efetividade do clareamento dental ao longo do tempo (p<0,001). Para ambos os grupos não foi verificada diferença estatística no risco absoluto de sensibilidade entre os grupos (p=1,0). A maioria dos pacientes apresentou sensibilidade dental leve e não foi detectada diferença estatisticamente significante entre os grupos, tanto para a escala NRS (p=0,529) como para a VAS (p=0,258). Concluiu-se que o clareamento dental foi eficaz para os grupos avaliados, o que torna possível o consumo de café durante o tratamento clareador.
46

Avaliação do desgaste superficial do esmalte e da dentina radicular submetidos ao tratamento clareador: in vitro e in situ / Evaluation of enamel and root dentin surface wear submitted to bleaching treatment: in vitro and in situ

Juliana Jendiroba Faraoni Romano 16 May 2008 (has links)
Devido a alterações químico-estruturais causadas pelo clareamento, os substratos dentais poderiam tornar-se mais susceptíveis a perda tecidual, principalmente se expostos a desafios erosivo/abrasivos. Desta forma, o presente estudo teve como objetivos: 1) analisar in vitro, se o esmalte e a radicular dentina clareada com diferentes agentes e concentrações, apresenta uma maior susceptibilidade ao desgaste, quando submetido a ciclos de erosão e abrasão; 2) comparar o efeito da aplicação de um agente clareador a base de peróxido de carbamida a 10% a um placebo no desgaste do esmalte e da dentina radicular, através de um modelo in situ. Os resultados do estudo in vitro mostraram que, independentemente do agente usado, o clareamento não aumentou o desgaste do esmalte frente a episódios erosivo-abrasivos. Na dentina, o desgaste foi dependente do agente clareador aplicado. Baseado no protocolo in situ adotado, o peróxido de carbamida a 10% não causou maior desgaste superficial no esmalte, mas aumentou a perda de tecido dentinário comparado ao placebo. Pode-se concluir que, em termos de desgaste superficial, o esmalte não foi afetado pelo tratamento clareador, enquanto a dentina mostrou-se mais susceptível. Assim, sugerem-se cuidados adicionais na seleção do agente clareador em situações clínicas que apresentam dentina radicular exposta. / Due to the chemical and microstructural alterations caused by bleaching, the dental substrates can become more susceptible to tissue loss, mainly if exposed to erosive/abrasive challenges. Therefore, the present study had the following objectives: 1) to analyze in vitro, if enamel and root dentin that had been bleached with different agents and concentrations, were at increased risk of wear when submitted to cycles of erosion and abrasion; 2) to compare the effect of the application of a 10% carbamide peroxide bleaching agent to a placebo on wear of enamel and root dentin, through an in situ model. The results of the in vitro study showed that independent of agent used, the bleaching demonstrated no increase in the wear of enamel when exposed to the erosive-abrasive episodes. In dentin, the wear was dependent on the bleaching agent applied. Based on the in situ protocol adopted, the 10% carbamide peroxide did not cause higher wear on the enamel, but increased the wear of the root dentin compared to the placebo. It could be concluded that in terms of superficial wear, enamel was not affected by bleaching treatment, while dentin showed to be more susceptible. Thus, additional caution is suggested in the choice of the bleaching agent when root dentin is exposed.
47

Influência do tipo de polimento pós-clareamento na alteração de rugosidade, cor e brilho da superfície de esmalte dental humano / Different polishing procedures influence in roughness, color and gloss of bleached human dental enamel surface

Ana Carolina Pedreira de Freitas 05 November 2010 (has links)
O tratamento clareador pode resultar em alterações na rugosidade superficial do esmalte dental, as quais podem ser vistas a olho nu como alterações de cor, opacidade e perda de brilho. O objetivo deste estudo foi analisar in vitro a alteração de rugosidade, cor e brilho de superfícies de esmalte dental humano após clareamento com um produto a base de peróxido de hidrogênio (PH) 38% e após polimento com fluoreto de sódio 2% neutro (FS2%) ou pasta dentifrícia contendo partículas de nano-hidroxiapatita. Para isso, coroas de incisivos centrais humanos foram preparadas e tiveram suas faces vestibulares analisadas em microscópio de força atômica (MFA), o qual determinou os valores de rugosidade [Ra, RMS, Z range e Power Spectral Density (PSD)] iniciais. A cor e o brilho destas amostras foram determinados por um espectrofotômetro. Todas as amostras foram clareadas com PH 38% por 135 minutos. Os valores de Ra, RMS, Z range e PSD foram estabelecidos pelo MFA e a cor e o brilho determinados pelo espectrofotômetro. As amostras foram divididas em dois grupos: Flúor, que recebeu um polimento com gel de FS2%; e nHA, que recebeu um polimento com pasta dentifrícia contendo partículas de nano-hidroxiapatita. Os valores de Ra, RMS, Z range, PSD, cor e brilho pós-polimento foram determinados pelo MFA e espectrofotômetro. Após o clareamento, os valores de Ra, RMS, Z range e PSD não apresentaram alteração estatisticamente significante, os valores de L* aumentaram e C* diminuiu significativamente em todas as amostras. O brilho superficial não apresentou alteração significativa após o clareamento. O grupo Flúor não apresentou alteração de rugosidade significativa para Ra, RMS, Z range e PSD após o polimento. Os valores de L*, C* e brilho superficial também não apresentaram alterações significativas após o polimento das superfícies clareadas. No grupo nHA, os valores de Ra e RMS não apresentaram alteração significativa após o polimento das superfícies clareadas, porém os valores de Z range e PSD apresentaram alteração estatisticamente significante. Em comparação à superfície clareada, L* e C* não apresentaram alteração significante após o polimento, porém o brilho superficial foi significativamente maior. O tratamento clareador de consultório mostrou ser eficiente quanto à alteração de cor e não gerou aumento na rugosidade superficial do esmalte dental. Um polimento com pasta dentifrícia contendo partículas de nano-hidroxiapatita realizado após o clareamento é capaz de aumentar o brilho e diminuir a rugosidade superficial do esmalte dental. / Bleaching treatment may result in dental enamel surface roughness alterations, which might be seen as color alterations, opacity and gloss loss. The aim of this research was to in vitro investigate roughness, color and gloss alterations of human dental enamel surfaces after bleaching treatment with 38% hydrogen peroxide (HP) and after polishing with neutral 2% sodium fluoride or dental tooth paste containing nano-hydroxiapatite particles. Human central incisors were prepared and buccal surfaces were analyzed by an atomic force microscope (AFM), which determined roughness values [Ra, RMS, Z range and Power Spectral Density (PSD)]. Surface color and gloss were determined by a spectrophotometer. All samples were bleached with 38% HP for 135 minutes. AFM determined Ra, RMS, Z range and PSD after bleaching. Color and gloss were determined by the spectrophotometer. Samples were distributed in two different groups: Fluor, which was polished with neutral 2% sodium fluoride, and nHA, which was polished with dental tooth paste containing nano-hydroxyapatite particles. Ra, RMS, Z range, PSD, color and gloss values were determined by AFM and spectrophotometer after polishing. After bleaching, Ra, RMS, Z range and PSD didnt show any statistical difference. L* increased and C* decreased significantly in all samples after bleaching. Surface gloss didnt show significant alteration after bleaching. Fluor group didnt show surface roughness alteration considering Ra, RMS, Z range and PSD after polishing. L*, C* and gloss didnt change after bleached surfaces are polished with neutral 2% sodium fluoride. Ra and RMS of nHA group didnt change significantly after polishing, but Z range and PSD showed significant alteration. Despite L* and C* didnt change, gloss increased significantly after polishing with dental tooth paste containing nano-hydroxyapatite. In-office bleaching treatment showed to be efficient as for color enhancement and didnt cause roughness alteration in dental enamel surface. An after-bleaching polishing with dental tooth paste containing nano-hydroxyapatite particles may increase gloss and decrease surface roughness of dental enamel.
48

Citotoxicidade e genotoxicidade do percarbonato de sódio: comparação com agentes clareadores comumente utilizados no tratamento de dentes despolpados / Cytotoxicity and genotoxicity of sodium percarbonate: a comparison with bleaching agents commonly used in discolored pulpless teeth

MORÍNIGO, Maria Raquel Fernández 28 April 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:17Z (GMT). No. of bitstreams: 1 Dissertacao_Maria_Raquel_Fernandez_Morinigo.pdf: 1321282 bytes, checksum: 91f2eb8e65e4b67c642c6df035df822a (MD5) Previous issue date: 2009-04-28 / Aim: To evaluate the cytotoxicity and genotoxicity of sodium percarbonate in comparison with bleaching agents used in discolored pulpless teeth from a mouse fibroblast cell culture. Methodology: The bleaching agents cytotoxicity and genotoxity were evaluated both in their pure form of products as well as in concentration commonly used in clinical practice. Hydrogen peroxide (HP), carbamide peroxide (CP), sodium perborate (SP) and sodium percarbonate (SPC) were diluted in DMEM in series. To evaluate the cytotoxicity, the survival of 3T3 mouse fibroblasts were measured photometrically by using MTT assay after a 24h exposure period. Genotoxicity was indicated by the micronuclei (MN) formation and the modification of the normal cell was analyzed by light microscopy (400x). The statistical analysis was performed by one-way ANOVA, followed by a multiplecomparison Tukey post hoc test (p < 0.05). Results: All tested groups exhibited a dose-dependent cytotoxicity. However, CP has showed a similar cytotoxic effect when compared with DMEM untreated control (UC) group. PH and SPC were significantly more cytotoxic than SP. Genotoxicity test has showed that SPC and SP have presented an intermediate rate of MN frequency over the UC group. The mean rate of MN frequency to HP was higher and statistically more significant than other groups tested. No difference was observed when CP and UC groups were compared. Conclusions: The results suggest that the cytotoxicity of SPC was similar to HP and significantly more cytotoxic than SP and CP. On the other hand, SPC and SP has shown an intermediate genotoxic effect, lower than HP and higher than CP, which was non-genotoxic / Objetivo: Avaliar a citoxicidade e genotoxidade do percarbonato de sódio e comparar com os agentes clareadores comumente utilizados no tratamento de dentes despolpados em cultura celular. Metodologia: A citotoxidade e genotoxicidade dos agentes clareadores foram avaliadas tanto na forma pura de cada produto quanto nas concentrações utilizadas na prática clínica. Peróxido de Hidrogênio (PH), peróxido de carbamida (PC), perborato de sódio (PS) e percarbonato de sódio (PCS) foram diluídos em DMEM. A viabilidade de fibroblastos da linhagem 3T3/NIH após 24h de exposição aos diferentes agentes foi medida fotometricamente por meio do teste colorimétrico com MTT. A genotoxicidade foi indicada pela formação e contagem de micronúcleos (MN) analisados em microscópio óptico comum (400x). A análise estatística dos dados foi feita utilizando o teste ANOVA de uma via complementado com o teste de comparações múltiplas Tukey post hoc (p < 0, 005). Resultados: Todos os grupos testados apresentaram um efeito citotóxico dosedependente. Entretanto, o PC mostrou citotoxicidade semelhante ao grupo controle (GC). PH e PCS foram significativamente mais citotóxicos que PS. O teste de genotoxicidade mostrou que PCS e PS apresentaram uma frequência intermediária de MN quando comparados ao GC. Por outro lado, a frequência média de MN usando PH foi significantemente superior aos outros grupos testados (p < 0, 005). Não houve diferença estatística entre PC e o GC. Conclusão: A citotoxicidade do PCS foi similar ao PH e significantemente maior do que o PS. Por outro lado, PCS e PS apresentaram um efeito genotóxico intermediário, inferior ao PH, porém superior ao PC que não teve efeito genotóxico

Page generated in 0.5156 seconds