• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 212
  • 2
  • 1
  • Tagged with
  • 217
  • 119
  • 57
  • 34
  • 32
  • 23
  • 23
  • 23
  • 21
  • 20
  • 20
  • 19
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Analise quantitativa e qualitativa da atividade eletrica das porções do M. Retus Abdominis

Negrão Filho, Ruben de Faria 25 June 1999 (has links)
Orientador: Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T09:14:39Z (GMT). No. of bitstreams: 1 NegraoFilho_RubendeFaria_D.pdf: 4902791 bytes, checksum: ed465df9bf7abab5e1ea395970684ead (MD5) Previous issue date: 1999 / Resumo: o objetivo deste estudo foi verificar o comportamento de três porções do M. reto do abdome, através de análise quantitativa do sinal eletromiográfico, em diferentes tipos de exercícios abdominais. Foram estudados dez indivíduos jovens, sem história de doença articular ou muscular, do sexo masculino, de 16 a 27 anos, bem treinados e que realizaram sete exercícios abdominais, escolhidos considerando o tipo de contração (isotônica e isométrica) e os pontos de fixação do músculo. A atividade elétrica das porções superior, média (supra-umbilical) e inferior (infra-umbilical) no lado esquerdo do M. reto do abdome foram captadas através de mini-eletrodos de superfície, tipo Beckman. Os registros foram realizados no eletromiógrafo marca Nicolet, modelo Viking II da Nicolet Biomedical Instruments, de 8 canais, computadorizado. Os sinais foram quantificados utilizando o software MV A (Atividade Máxima Voluntária), sendo considerado para análise os valores de RMS (Raiz Quadrada da Média). Os dados obtidos foram submetidos a análise paramétrica, empregando-se análise de variância (teste F) e teste de Tukey, além da análise gráfica descritiva a partir da média dos valores de RMS de cada uma das porções do músculo. Os resultados deste estudo sugerem que para a grande maioria dos indivíduos, as atividades funcionais do M. reto do abdome são realizadas com diferenças de atividade elétrica entre suas porções, apresentando uma tendência da porção superior em apresentar maior atividade elétrica do que as porções média e inferior. Constatou-se também, a ausência de um padrão de comportamento comum das três porções do músculo, para os dez indivíduos testados / Abstract: This study objective was to verify the behavior of three portions of the rectus abdominis muscle through a quantitative analysis of the electromyographic signal in different types of abdominal exercises. Ten young male subjects between 16 and 27 years old were studied and they had no previous history of muscle and joint ilnesses. They were well-trained and did seven abdominal exercises chosen considering the types of contraction (isotonic and isometric) as well as the muscle fixation points. The electrical activity of the superior, medium (above navel) and inferior (below navel) portions at the left side of the rectus abdominis muscle was taken using Beckman type surface mini-electrodes. lihe registers were collected from computerized 8 channel Nicolet electromyography equipment, model Viking 11 made by Nicolet Medical Instruments. The signals were quantifield using the MV A (Maximum Volunteer Activity) software, being considered for analysis the values of RMS (Root Means Square). The obtained data were submitted to a parametric analysis using the variance analysis (F test) and also the Tukey test, besides a I descriptive graphic analysis starting from the RMS medium values of each muscle portion. This study results suggest that for the majority of the subjects, the functional activities of the rectus abdominis muscle performed with differences among their portions electrical activitity, showing a tendency in the superior portion of producing more electrical activity than the medium and the inferior portions. Ttae experiment also demonstrated an absence of a common behavior patter in the three portions of the ten tested subjects / Doutorado / Doutor em Ciências
22

Estudo eletromiografico das porções do M. Rectus abdominis

Negrão Filho, Ruben de Faria 11 August 1995 (has links)
Orientador: Fausto Berzin / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T14:30:22Z (GMT). No. of bitstreams: 1 NegraoFilho_RubendeFaria_M.pdf: 3448567 bytes, checksum: 49014fcd937e3e1720e34845a81d7e5c (MD5) Previous issue date: 1995 / Resumo: o objetivo deste estudo foi investigar o comportamento do M. rectus abdominis através de análise quantitativa e qualitativa dos sinais eletromiográficos obtidos de suas porções superior, média e inferior durante atividade dinâmica e estática. Participaram deste estudo dez (10) voluntários, atletas, do sexo masculino, com idade variando de 16 a 21 anos (média = 17.8), sem história de disfunção músculo-esquelética. A atividade estática foi realizada através do exercício isométrico de flexão do tronco ereto em 5 diferentes ângulos e a atividade dinâmica foi realizada através do exercício isotônico de flexão e extensão do tronco a partir da posição supina. Para a análise do estudo quantitativo os valores da raiz quadrada da média obtidos dos traçados eletromiográficos durante os exercícios isométricos foram submetidos ao processo de normalização e expressos em porcentagem da contração isométrica voluntária máxima. Para o estudo qualitativo da atividade dinâmica os traçados eletromiográficos foram tratados através de retificação, envoltória linear e normalização, de forma que a curva resultante do processamento foi analisada comparativamente. Os resultados do estudo quantitativo mostraram que não existiu diferença estatisticamente significativa entre as diferentes porções do músculo. Na análise qualitativa dos gráficos observou-se um padrão de ativação elétrica comum para as diferentes porções do M. rectus abdominis, não sendo observado diferenças significativas no ângulo de inclinação de subida e descida do traçado durante o movimento isotônico de flexão e extensão do tronco / Abstract: The purpose of this study was to investigate the electrical behavior of the Rectus abdominis muscle by qualitative and quantitative analysis of the electromyographic signal obtained from its superior, medium and inferior portions during dynamic and static activities. Ten voluntaries (aged X = 17.8 years, 50 = 1.6) athletic males were studied without history of muscle skeletal disfunction. The static activity was carried out by isometric exercise of the trunk erect flexion in five different angles and the dynamic activity by isotonic exercise 01 / Mestrado / Mestre em Ciências
23

Efeitos do treinamento físico sobre a função cardíaca e as propriedades mecânicas em cardiomiócitos de camundongos knockout para os receptores β2-adrenérgicos / Effects of exercise training on cardiac function and mechanical properties in cardiomyocytes from β 2 adrenergic receptors knockout mice

Costa, Alexandre Jayme Lopes Dantas 27 August 2018 (has links)
Submitted by MARCOS LEANDRO TEIXEIRA DE OLIVEIRA (marcosteixeira@ufv.br) on 2018-10-08T12:38:35Z No. of bitstreams: 1 texto completo.pdf: 1787653 bytes, checksum: d47fa7116143fe4f93ee855509e5e86a (MD5) / Made available in DSpace on 2018-10-08T12:38:35Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1787653 bytes, checksum: d47fa7116143fe4f93ee855509e5e86a (MD5) Previous issue date: 2018-08-27 / O objetivo do presente estudo foi investigar os efeitos do exercício aeróbico continuo de intensidade moderada (EACM) sobre as propriedades mecanicas e funcionais de cardiomiócitos de camundongos knockout (KO) para receptores para os receptores β2 -adrenérgicos. Camundongos FVB/N e KO com 4 meses de idade foram inicialmente separados aleatoriamente em 4 grupos: selvagem controle (FVBc; n = 11), selvagem treinado (FVBt; n = 11), KO β2 controle (KO 2 c; n = 12) e KO treinado (KO 2 t; n = 12). Os animais dos grupos treinados (FVBt e KO 2 t) foram submetidos a um protocolo de treinamento aeróbico de 8 semanas, 5 dias por semana, 1 hora por dia, com intensidade de 60% da velocidade máxima de corrida. Após a eutanásia, os cardiomiócitos do ventriculo esquerdo foram isolados por dispersão enzimática. A função cardíaca, os parametros contráteis e o transiente de [Ca 2+ ] i dos cardiomiócitos do ventrículo esquerdo foram mensurados. P ≤ 0,05 foi considerado significativo em todas as comparações. Os resultados mostram que o EACM aumentou a capacidade de corrida em camundongos KO e FVB, embora a fração de encurtamento e a fração de ejeção não tenha sido alterada em camundongos KO 2 . Camundongos KO 2 t também apresentaram menor amplitude de contração, menor tempo para o pico de contração e menor tempo para 50% de relaxamento do que os camundongos FVBt. Além disso, camundongos KO 2 t apresentaram menor amplitude Ca 2+ e menor tempo para 50% de decaimento comparado com camundongos FVBt. Em conclusão, o EACM reduziu a amplitude de contração, o tempo para pico de contração e a aplitude do Ca 2+ nos cardiomiócitos de camundongos KO 2 / The aim of this study was to investigate the effects of Moderate Continuous Aerobic Exercise (MCAE) on the mechanical and functional properties in cardiomyocytes from β adrenergic receptor knockout mice (KO). Four-month-old FVB/N and KO mice were initially randomly divided into 4 groups: control wild (FVBc; n= 11), trained wild (FVBt; n= 11), control KO (KO 2 c; n= 12) e trained KO 2 t) 2 (KO 2 t; n= 12). The animals of the trained groups (FVBt, KO were submitted to a protocol of aerobic training 8 weeks, 5 days/week, 1 hour/day, intensity of 60% of maximal speed. At sacrifice, the heart was removed and left ventricular myocytes were enzymatically dispersed. Cardiac function, contractile parameters, and [Ca 2+ ] i transient of left ventricular cardiomyocytes were measured. P ≤ 0.05 was considered significant in all comparisons. The results showed that the MCAE increased the running capacity in KO FVB mice, although the shortening fraction and the ejection fraction were not altered in 2 e KO mice. KO 2 t mice also showed lower contraction amplitude and shorter times to peak and to 50% relaxation than FVBt mice. In addition, KO 2 t mice showed lower Ca 2+ transient amplitude and shorter time to 50% decay of the Ca 2+ transient than WT mice. In conclusion, MCAE reduced the contraction amplitude, time to peak and Ca 2+ transient amplitude in cardiomyocytes from KO mice.
24

Efeito das sessões de familiarização sobre o pico de torque e taxa de desenvolvimento de torque = comparações entre jovens, meia idade e idosos = Effect of familiarization sessions on peak torque and rate of torque development : comparisons among young, middle age and elderly / Effect of familiarization sessions on peak torque and rate of torque development : comparisons among young, middle age and elderly

Fazolin, Marcio Aparecido Franco de Godoy, 1981- 04 September 2013 (has links)
Orientador: Cláudia Regina Cavaglieri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Física / Made available in DSpace on 2018-08-22T16:14:08Z (GMT). No. of bitstreams: 1 Fazolin_MarcioAparecidoFrancodeGodoy_M.pdf: 1352810 bytes, checksum: bb34bcd02d7a93531f2f4ca3be5a26c0 (MD5) Previous issue date: 2013 / Resumo: A contração muscular isocinética, assim como a isométrica balística, tem sido utilizada para determinar o pico de torque (PT) e a taxa de desenvolvimento de torque (TDT), consideradas importantes variáveis neuromusculares. Sessões de familiarização são necessárias para a verificar a estabilidade das medidas em diferentes protocolos de verificar a estabilidade destas medidas. No entanto, ainda não estão claro quantas sessões de familiarização são necessários para estabilizar tais componentes em diferentes idades. O objetivo deste estudo foi determinar o número de sessões de familiarização necessárias para alcançar a estabilidade da medida no PT e TDT a partir da contração isométrica balística e o PT a partir da contração isocinética nas velocidades 60º/s, 180º/s, 240º/s e 300º/s, nas faixas etárias. Sessenta e quatro sujeitos saudáveis participaram de dois protocolos de familiarização: o isométrico balístico, com 31 sujeitos dividos em jovem (idade de 22,75 ± 4,53 anos), meia-idade (idade de 50,45 ± 6,12 anos) e idosos (idade de 67,80 ± 7,28 anos); e o protocolo isocinético com 33 sujeitos dividos em jovens (idade de 21,92 ± 2,57), meia idade (idade de 47,20 ± 5,18 anos) e idosos (idade de 62,08 ± 3,53 anos). Foram realizadas quatro sessões de testes no dinamômetro isocinético separadas por 72h. De acordo com ANOVA, não foram observadas diferenças estatisticamente significantes entre os grupos e entre as sessões respectivamente (jovens, P = 0,92, P = 0,74; meia idade, P = 0,98, P = 0,99; idoso, P = 0,99, P = 0,69) para o protocolo isométrico balístico. Por outro lado, o protocolo isocinético apresentou uma variabilidade nas sessões de familiarização em relação às velocidades angulares analisadas (60º/s e 240ºs, jovem, P = 0,007 e P = 0,02 e meia idade, P = 0,01 e P = 0,007 e grupo idoso 240º/s e 300ºs, P = 0,02 e P = 0,05). Em conclusão, é possível que o nível de atividade física dos sujeitos e o tipo de protocolo utilizado tenham influenciado nas respostas do presente estudo. Os efeitos emanados do processo de envelhecimento parecem influenciar de forma mais acentuada as respostas do PT em contrações isocinéticas / Abstract: The muscular isokinetic contraction, as well as ballistic isometric, has been used to determine the peak torque (PT) and the rate of torque development (RTD), considered important neuromuscular variables. Familiarization sessions are necessary to verify the stability of neuromuscular measures in different protocols. However, it is unclear yet how many familiarization sessions are needed to stabilize these components at different ages. The aim of this study was to determine the number of familiarization sessions required to reach the stability of measure in the PT and RTD from the ballistic isometric contraction and in the PT from the isokinetic contraction at speeds 60°/s, 180º/s, 240º/s and 300º/s in different groups. Sixty-four healthy subjects participated in two familiarization protocols: the ballistic isometric , with 31 subjects divided in, young (age 22.75 ± 4.53 years), middle-age (age 50.45 ± 6.12 years) and elderly (age 67.80 ± 7.28 years): and isokinetic protocol with 33 subjects divided in young (age 21.92 ± 2.57 years), middle age (age 47.20 ± 5.18 years) and elderly (age 62.08 ± 3.53 years). There were four test sessions in isokinetic dynamometer with 72h apart. According to ANOVA, there were no statistically significant differences among groups and among sessions respectively (young P = 0.92, P = 0.74; middle age, P = 0.98, P = 0.99; elderly, P = 0.99, P = 0.69) for the ballistic isometric protocol In the other hand, the isokinetic protocol showed variability in familiarization sessions related to angular velocities analyzed. The number of familiarization sessions to reach the stabilization of PT was divergent angular in angular velocities. In conclusion, it is possible that the level of physical activity of the subjects and the type of protocol used have influenced on responses of the present study. The effects arisen from the aging process seem influence more sharply the responses of PT in isokinetic contractions / Mestrado / Atividade Fisica Adaptada / Mestre em Educação Física
25

"Avaliação da contração de polimerização de uma resina composta fotopolimerizável de uso universal, variando-se a técnica de inserção do material medida por picnômetro a gás" / Polymerization shrinkage evaluation of an universal light curing composite resin, varying the placement techniques, measured by gas pycnometer

Salgado Júnior, Luiz Paulo dos Santos 05 August 2004 (has links)
RESUMO Dada sua versatilidade e excelência estética, a resina composta é o material restaurador direto mais utilizado nas intervenções da clínica odontológica. Uso tão intenso levou pesquisadores e fabricantes a trabalharem na evolução deste material, conferindo-lhe aumento em sua resistência à compressão e abrasão, bem como melhora em seu comportamento estético. Infelizmente, um problema intrínseco da resina, a contração de polimerização é sua principal desvantagem, e caracteriza-se pela alteração volumétrica que sofre quando as moléculas de seus monômeros se unem para a formação das cadeias poliméricas. Uma das principais técnicas para combater os efeitos nocivos desta alteração volumétrica é a inserção incremental do material na cavidade a ser restaurada. Nesta pesquisa, a contração de polimerização de uma resina composta de uso universal (Charisma Heraeus Kullser) será avaliada variando-se a técnica de inserção do material na cavidade em incremento único ou três incrementos oblíquos, através do método da picnometria a gás. O picnômetro Accupyc 1330 (Micromeritics) permite medições rápidas e fiéis do volume da resina composta antes e após a fotoativação. Os resultados mostram que ocorreram diferenças estatísticas entre as duas técnicas, sendo a técnica de único incremento a que apresentou menor contração de polimerização. / Because of its versatility and aestetic excellency, composite resin is one of the most utilized direct restorative materials. Because of the resin intense use, the number of researches to improve its performance are numerous, and can be verified by the resin aestethetic behavior and its compressive and abrasion strenght increase. In spite of the mentioned developments, the polymerization shrinkage inherent of the material had been a major deficiency, and can be understood by the alteration in volume of the material after the polymerization process. In the present study, the polymerization shrinkage of the restorative material Charisma (Heraes Kulzer), was evaluated using bulk and incremental placement techniques and measured by gas pycnometer. Accupyc 1330 (Micromeritics, USA) pycnometer measures the helium displacement with great precision, allowing fast and accurate measurements of the volume of the composite resin before and after polymerization, without interference of the moisture or temperature. The results showed statistically significant diferences between the two placement techniques, with the bulk technique showing lower polymerization shrinkage than the incremental technique.
26

Comparação de duas técnicas de fotopolimerização nas propriedades de contração e temperatura de polimerização de uma resina de incremento único por meio das redes de Bragg / Comparison of the contraction and polymerization temperature of a single increment resin by means of the Bragg networks using two photopolymerization techniques

Costa, Manoela Maria Machado 16 February 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-05-21T18:29:42Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Manoella Maria Machado Costa.pdf: 2056005 bytes, checksum: cea06c624bdf599dba9ef2d9e2c099ab (MD5) / Made available in DSpace on 2018-05-21T18:29:42Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Manoella Maria Machado Costa.pdf: 2056005 bytes, checksum: cea06c624bdf599dba9ef2d9e2c099ab (MD5) Previous issue date: 2018-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do estudo foi avaliar a influência dos modos de fotoativação Contínua e Ramp nas propriedades de contração de polimerização e alteração térmica de uma resina composta Filtek™Bulk Fill Flow. Foram selecionados 30 dentes terceiros molares hígidos nos quais foi preparada uma cavidade de Classe I oclusal (4 mm de comprimento x 4 mm de largura x 4 mm de profundidade). Para o posicionamento dos sensores de Bragg, um sensor foi posicionado no sentido mésio-distal diretamente em contato com a resina que mediu a deformação de contração, e outro no interior de uma agulha hipodérmica no sentido vestíbulo-lingual que mediu somente a temperatura. Os dentes foram restaurados com a resina Filtek ™ Bulk Fill Flow de acordo com as recomendações do fabricante. Posteriormente, utilizou-se uma fórmula para obter o valor de deformação pura do material em μstrain. A análise estatística foi obtida por meio de análise de variância e teste t de Student. Os resultados revelaram não haver diferenças estatísticas significativas para os valores de contração entre os dois protocolos de fotoativação (Contínuo e Ramp) e entre os tempos de 500s, 1500s, 2500s e 3500s. Ao final de 3500s observou-se uma tendência à estabilização das curvas para ambos os modos de fotoativação. A fotoativação Ramp revelou maior valor de variação de temperatura (16,32°C) quando comparada à fotoativação Contínua (7,8°C). Os sensores de Bragg foram capazes de medir a alteração de contração e a variação térmica. A fotoativação contínua demorou mais para retornar ao valor inicial de temperatura (2,85 min) que a Ramp (1,65 min). Futuros estudos devem monitorar a contração de polimerização por um intervalo de tempo maior necessário para a estabilização total da curva. / The objective of this study was to evaluate the influence of Continuous and Ramp photoactivation modes on the shrinkage polymerization, and thermal change properties of a Filtek™ Bulk Fill Flow composite. 30 third molar teeth were selected. An occlusal Class I cavity (4 mm length x 4 mm wide x 4 mm depth) was prepared.For the positioning of the Bragg sensors, a sensor was positioned in the mesio-distal direction directly in contact with the composite that measured the shrinkage deformation, and another sensor inside a hypodermic needle in the lingual-lingual direction that measured only the temperature. The teeth were restored with Filtek™Bulk Fill Flow resin according to the manufacturer's recommendations. Subsequently, was used a formula to obtain the pure deformation value of the material in μstrain. Statistical analysis was obtained through analysis of variance and Student's t-test. The results showed no significant statistical differences for the shrinkage values between the two photoactivation protocols (Continuous and Ramp) and among 500s, 1500s, 2500s and 3500s times. At the end of 3500s a tendency to stabilize the curves for both modes of photoactivation was observed. The Ramp photoactivation revealed a higher value of temperature variation (16.32°C) when compared to Continuous photoactivation (7.8 °C). The Bragg sensors were able to measure the shrinkage, and the thermal variation. Continuous photoactivation took longer to return to the initial temperature value (2.85 min) than ramp (1.65 min). Future studies should monitor the shrinkage of polymerization for a longer period of time necessary for the total stabilization of the curve.
27

Estimulação elétrica transvaginal no tratamento da incontinência urinária

Barroso, Julia Cristina Vieira January 2002 (has links)
Objetivo - Determinar a efetividade da estimulação elétrica transvaginal (EE) no tratamento da incontinência urinária (IU) e avaliar a melhora clínica após seis meses do término do tratamento. Delineamento - Ensaio clínico randomizado controlado e cego. Instituição - Serviços de Ginecologia e Obstetrícia e de Engenharia Biomédica do Hospital de Clínicas de Porto Alegre, UFRGS. Métodos - Foram selecionadas 36 mulheres (24 casos e 12 controles), com IU de esforço, urgência ou mista, para utilização de equipamento de EE ou placebo (equipamento idêntico, sem corrente elétrica). As pacientes fizeram o tratamento em casa, duas vezes ao dia (sessões de 20 minutos), durante 12 semanas. Preencheram diário miccional e realizaram estudo urodinâmico no início e final do tratamento. Foram reavaliadas clinicamente após seis meses. Resultados - O tempo médio de utilização do equipamento foi semelhante nos grupos (em torno de 40h). O grupo que fez EE apresentou aumento significativo da capacidade vesical máxima e redução significativa no número de micções totais (durante o período de 24h), no número de micções noturnas, no número de episódios de urgência miccional e, principalmente, no número de episódios de incontinência urinária. Na primeira avaliação, após o término do tratamento, 87,5% das pacientes estavam satisfeitas. Na reavaliação semestral, 33% das pacientes necessitaram de outra abordagem terapêutica e 67% estavam curadas ou melhores. Conclusão - A EE é uma alternativa prática, com poucos efeitos colaterais, e efetiva no tratamento das principais formas de IU feminina.
28

Efeitos da dinâmica da pressão abdominal na modulação do retorno venoso de membros inferiores e em parâmetros hemodinâmicos centrais em indivíduos saudáveis e pacientes com insuficiência cardíaca

Balzan, Fernanda Machado January 2013 (has links)
Resumo não disponível
29

Investigação da participação de adrenoceptores α1A e α1D na contração da cauda de epididímo de rato e sua androgênica e estrogênica

Kiguti, Luiz Ricardo de Almeida [UNESP] 30 September 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-09-30. Added 1 bitstream(s) on 2015-06-18T12:47:23Z : No. of bitstreams: 1 000827131_20160930.pdf: 1032389 bytes, checksum: 1ec652e603aca7989376c865a7b92ae6 (MD5) Bitstreams deleted on 2016-10-03T12:15:51Z: 000827131_20160930.pdf,. Added 1 bitstream(s) on 2016-10-03T12:16:37Z : No. of bitstreams: 1 000827131.pdf: 2564151 bytes, checksum: 723e8967f02bfb11f977abb54f8c05f4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Programa de Doutorado Sanduíche no Exterior (PDSE) / O epidídimo é o órgão do sistema reprodutor masculino responsável pela maturação e armazenamento dos espermatozóides. A contração da cauda do epidídimo (CE) é um dos primeiros eventos da fase de emissão seminal da ejaculação e o sistema nervoso autônomo simpático desempenha um papel importante na contração da CE através da ativação de adrenoceptores α1 (α1-ARs). Neste estudo mostramos que a CE expressa α1A-ARs e α1D-ARs e que ambos os receptores contribuem, de um modo complexo, para a contração da CE induzida por agonistas α1. Na ausência de ativação por agonistas o α1D-ARs modula a contração induzida pela ativação de α1A-ARs por agonistas exógenos. Os α1A-ARs da CE não são dessensibilizados pela oximetazolina. Os andrógenos desempenham um papel importante na manutenção da interação entre os α1A/1D-ARs visto que a redução de andrógenos, mas não de estrógenos, pela castração evidencia a presença dos α1D-ARs. A interação complexa entre os 1A/α1D-ARs é discutida no contexto de heterodimerização de receptores visto que mostramos, pela primeira vez, a heterodimerização entre os α1A e α1D-ARs recombinantes humanos / The epididymis is the male reproductive organ responsible for sperm maturation and storage. The contraction of cauda epididymis (CE) during ejaculation is one of the first events of seminal emission phase of ejaculation and the sympathetic nervous system plays a key role in the CE contraction via α1 adrenoceptors (α1-ARs) activation. In this study we show that CE expresses α1A and α1D-ARs and both receptor subtypes contribute in a complex way to the CE contraction induced by α1-ARs agonists. The α1D modulates α1A-ARs induced contraction irrespective of agonist-mediated α1D activation. There is no desensitization of CE α1A-ARs to oxymetazoline. The androgens were shown to play an important role in the maintenance of such α1A/α1D interaction as the androgen deprivation unravels the cryptic functional α1D-ARs. Estrogens had no effect on α1-ARs mediated contraction of CE. The complex α1A/α1D interaction is discussed in the context of receptor heterodimerization as we showed, for the first time, heteromerization of recombinant α1A/α1D-ARs / Programa de Doutorado Sanduíche no Exterior (PDSE): 12355/13-5
30

Estimulação elétrica transvaginal no tratamento da incontinência urinária

Barroso, Julia Cristina Vieira January 2002 (has links)
Objetivo - Determinar a efetividade da estimulação elétrica transvaginal (EE) no tratamento da incontinência urinária (IU) e avaliar a melhora clínica após seis meses do término do tratamento. Delineamento - Ensaio clínico randomizado controlado e cego. Instituição - Serviços de Ginecologia e Obstetrícia e de Engenharia Biomédica do Hospital de Clínicas de Porto Alegre, UFRGS. Métodos - Foram selecionadas 36 mulheres (24 casos e 12 controles), com IU de esforço, urgência ou mista, para utilização de equipamento de EE ou placebo (equipamento idêntico, sem corrente elétrica). As pacientes fizeram o tratamento em casa, duas vezes ao dia (sessões de 20 minutos), durante 12 semanas. Preencheram diário miccional e realizaram estudo urodinâmico no início e final do tratamento. Foram reavaliadas clinicamente após seis meses. Resultados - O tempo médio de utilização do equipamento foi semelhante nos grupos (em torno de 40h). O grupo que fez EE apresentou aumento significativo da capacidade vesical máxima e redução significativa no número de micções totais (durante o período de 24h), no número de micções noturnas, no número de episódios de urgência miccional e, principalmente, no número de episódios de incontinência urinária. Na primeira avaliação, após o término do tratamento, 87,5% das pacientes estavam satisfeitas. Na reavaliação semestral, 33% das pacientes necessitaram de outra abordagem terapêutica e 67% estavam curadas ou melhores. Conclusão - A EE é uma alternativa prática, com poucos efeitos colaterais, e efetiva no tratamento das principais formas de IU feminina.

Page generated in 0.0664 seconds