• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 147
  • 30
  • 16
  • Tagged with
  • 191
  • 67
  • 63
  • 60
  • 58
  • 54
  • 47
  • 36
  • 35
  • 29
  • 27
  • 25
  • 24
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Power Enhancement of Piezoelectric Technology based Power Devices by Using Heat Transfer Technology / Amélioration de la puissance des transformateurs piézoélectriques par gestion de l'échauffement

Su, Yu-Hao 04 July 2014 (has links)
L’objectif de cette étude est d’améliorer les performances des transformateurs piézoélectriques en terme de courant de sortie et de puissance pour des applications d’alimentation DC/DC, grâce à la gestion de l’échauffement. Le courant de sortie des transformateurs piézoélectriques, et donc la puissance transmise, sont directement liés à la vitesse de vibration qui pour des valeurs élevées engendre des pertes et une forte élévation de température. Cette élévation excessive de la température a comme conséquence le changement des caractéristiques du transformateur et plus particulièrement la diminution du facteur de qualité Q. Ainsi cela entraine une limite structurelle de la puissance transmise du transformateur. Une solution pour augmenter le courant de sortie est l’utilisation d’un redresseur doubleur de courant, qui grâce à 2 inductances permet, à courant de charge donné, de diminuer la vitesse de vibration du transformateur, mais ne permet pas de régler le problème d’échauffement du transformateur. Dans cette thèse nous proposons des moyens d’évacuation de la chaleur ainsi que le choix de l’environnement dans lequel le transformateur devra fonctionner. L’influence de différents systèmes de refroidissement d’un convertisseur DC/DC à base transformateur piézoélectrique est étudiée. L’étude thermique du transformateur piézoélectrique multicouche polarisé en épaisseur et ayant des électrodes circulaires met en évidence un comportement non linéaire. Une plaque vibrante piézoélectrique est d’abord envisagée pour créer un flux d’air qui augmente l’évacuation de chaleur par convection, puis un module de refroidissement utilisant l’effet thermoélectrique. Les mesures montrent que la première solution est plus avantageuse car elle améliore sensiblement les performances du transformateur pour un coût énergétique très faible. Une étude thermique par éléments finis complète cette étude, montrant que l’approche par schéma électrique est pertinente. La puissance que peut délivrer le transformateur sur une charge optimale est encore augmentée. Enfin, ce travail montre qu’en combinant les dispositifs de refroidissement tout en respectant la condition de température inférieure à 55°C, le rendement du convertisseur reste raisonnable (70%) et la puissance disponible peut doubler dans le meilleur des cas. / The objective of this study was to increase the output current and power in a piezoelectric transformer (PT) based DC/DC converter by adding a cooling system. It is known that the output current of PT is limited by temperature build-up because of losses especially when driving at high vibration velocity. Excessive temperature rise will decrease the quality factor Q of piezoelectric component during the operational process. Simultaneously the vibration energy cannot be increased even if under higher excitation voltage. Although connecting different inductive circuits at the PT secondary terminal can increase the output current, the root cause of temperature build-up problem is not solved.This dissertation presents the heat transfer technology to deal with the temperature build-up problem. With the heat transfer technology, the threshold vibration velocity of PT can be increased and thus the output current and output power (almost three times).Furthermore, a comparison between heat transfer technology and current-doubler rectifier applied to the piezoelectric transformer based DC/DC converter was also studied. The advantages and disadvantages of the proposed technique were investigated. A theoretical-phenomenological model was developed to explain the relationship between the losses and the temperature rise. It will be shown that the vibration velocity as well as the heat generation increases the losses. In our design, the maximum output current capacity can increase 100% when the operating condition of PT temperature is kept below 55°C. The study comprises of a theoretical part and experimental proof-of-concept demonstration of the proposed design method.
122

Hierarchical control scheme for multi-terminal high voltage direct current power networks / Commande hiérarchique de réseaux multi-terminaux à courant continu et haute tension

Jimenez Carrizosa, Miguel 10 April 2015 (has links)
Cette thèse traite de la commande hiérarchique de réseaux à courant continu multi-terminaux à haute tension (MT-HVDC) intégrant des sources d'énergie renouvelables à grande échelle. Le schéma de contrôle proposé est composé de quatre ‘couches’ : le contrôle local où se trouvent les convertisseurs de puissance, avec une échelle de temps de l’ordre de la milliseconde ; le contrôle primaire qui est décentralisé et appliqué à plusieurs terminaux avec une échelle du temps de l’ordre de la seconde ; un niveau de commande où la communication est prise en compte et où l’approche de Modèle du Commande Prédictive (MPC) assure la planification de la tension et de la puissance à leur état d'équilibre, pour l'ensemble du système; enfin, le contrôleur de niveau supérieur, qui est principalement basé sur les techniques d'optimisation, où les aspects économiques sont pris en compte (il s’agit du réglage dit tertiaire).Au niveau des convertisseurs, un accent particulier est mis sur les convertisseurs bidirectionnels DC/DC. Dans cette thèse, trois topologies différentes sont étudiées en profondeur: deux phases Dual Active Bridge (DAB), trois phases DAB, et l’utilisation de la technologie Modular Multilevel converter (MMC) comme convertisseur DC/DC. Pour chaque topologie, une commande non-linéaire spécifique est discutée. D’autre part une nouvelle fonction pour le convertisseur DC/DC est étudiée. Il s’agit de son utilisation comme disjoncteur à courant continu (DC-CB). En ce qui concerne le contrôle primaire, qui permet de maintenir le niveau de tension continue dans le réseau, nous avons étudié trois philosophies de contrôle: celle de maître/esclave, celui du contrôle « voltage margin control » et celle de la commande du statisme (droop control). Enfin, nous avons choisi d'utiliser le droop control, entre autres, parce que la communication entre les nœuds n’est pas nécessaire. Concernant la commande secondaire, son principal objectif est de planifier le transfert de puissance entre les nœuds du réseau, qui fournissent la tension et la puissance de référence aux contrôleurs locaux et primaires, même lorsque des perturbations apparaissent. Dans cette partie, nous avons proposé une nouvelle approche pour résoudre les problèmes de flux de puissance (équations non-linéaires) basée sur le théorème du point fixe de l’application contractive. Ceci permet d'utiliser plus d'un slack bus, contrairement à l’approche classique basée sur la méthode de Newton-Raphson. Par ailleurs, le réglage secondaire joue un rôle très important dans les applications pratiques, en particulier lorsque les sources d'énergie renouvelables (variables dans le temps). Dans de tels cas, il est intéressant de considérer des dispositifs de stockage afin d'améliorer la stabilité de tout le système. Il est également possible d'envisager différents types de prévisions (météo, charge, ..) basées sur la gestion des réserves de stockage. Toutes ces caractéristiques ont suggéré l'utilisation d'une approche MPC. Dans ce contexte, plusieurs critères d'optimisation ont été considérés, en particulier la minimisation des pertes de transmission ou des congestions dans le réseau.La tâche principale de réglage tertiaire est de d'atteindre l'optimisation économique de l'ensemble du réseau. Dans cette thèse, nous avons pu maximiser le profit économique du système en agissant sur le marché réel, et en optimisant l'utilisation des périphériques de stockage. Dans le but de mettre en œuvre la philosophie de contrôle hiérarchique présentée dans cette thèse, nous avons construit un banc d'essai expérimental. Cette plate-forme dispose de quatre terminaux reliés entre eux par l'intermédiaire d'un réseau à courant continu, et connectés au réseau principal de courant alternatif. Ce réseau DC peut fonctionner à un maximum de 400 V, et avec une courant maximal de 15 A. / This thesis focuses on the hierarchical control for a multi-terminal high voltage direct current (MT-HVDC) grid suitable for the integration of large scale renewable energy sources. The proposed control scheme is composed of 4 layers, from the low local control at the power converters in the time scale of units of ms; through distributed droop control (primary control) applied in several terminals in the scale of unit of seconds; and then to communication based Model Predictive Control (MPC) that assures the load flow and the steady state voltage/power plan for the whole system, manage large scale storage and include weather forecast (secondary control); finally reaching the higher level controller that is mostly based on optimization techniques, where economic aspects are considered in the same time as longer timespan weather forecast (tertiary control).Concerning the converters' level, special emphasis is placed on DC/DC bidirectional converters. In this thesis, three different topologies are studied in depth: two phases dual active bridge (DAB), the three phases DAB, and the use of the Modular Multilevel Converter (MMC) technology as DC/DC converter. For each topology a specific non-linear control is presented and discussed. In addition, the DC/DC converter can provide other important services as its use as a direct current circuit breaker (DC-CB). Several operation strategies are studied for these topologies used as DC-CB.With respect to primary control, which is the responsible to maintain the DC voltage control of the grid, we have studied several control philosophies: master/slave, voltage margin control and droop control. Finally we have chosen to use droop control, among other reasons, because the communication between nodes is not required. Relative to the secondary control, its main goal is to schedule power transfer between the network nodes providing voltage and power references to local and primary controllers, providing steady state response to disturbances and managing power reserves. In this part we have proposed a new approach to solve the power flow problem (non-linear equations) based on the contraction mapping theorem, which gives the possibility to use more than one bus for the power balance (slack bus) instead of the classic approach based on the Newton-Raphson method. Secondary control plays a very important role in practical applications, in particular when including time varying power sources, as renewable ones. In such cases, it is interesting to consider storage devices in order to improve the stability and the efficiency of the whole system. Due to the sample time of secondary control is on the order of minutes, it is also possible to consider different kinds of forecast (weather, load,..) and to achieve additional control objectives, based on managing storage reserves. All these characteristics encourage the use of a model predictive control (MPC) approach to design this task. In this context, several possibilities of optimization objective were considered, like to minimize transmission losses or to avoid power network congestions.The main task of tertiary control is to manage the load flow of the whole HVDC grid in order to achieve economical optimization. This control level provides power references to the secondary controller. In this thesis we were able to maximize the economic profit of the system by acting on the spot market, and by optimizing the use of storage devices. In this level it is again used the MPC approach.With the aim of implementing the hierarchical control philosophy explained in this thesis, we have built an experimental test bench. This platform has 4 terminals interconnected via a DC grid, and connected to the main AC grid through VSC power converters. This DC grid can work at a maximum of 400 V, and with a maximum allowed current of 15 A.
123

Contribution à la continuité de service des convertisseurs statiques multiniveaux / Contribution to the continuity of service of multilevel converters

Becker, Florent 04 December 2017 (has links)
Ce mémoire s’inscrit dans le contexte général de la continuité de service des convertisseurs multiniveaux, lors de la défaillance d’un de leurs composants de puissance. Les structures concernées sont les topologies suivantes, largement utilisées dans les applications industrielles : Neutral Point Clamped (NPC) et Neutral Point Piloted (NPP) ou T-Type. Dans un premier temps, afin de limiter le taux de pannes du convertisseur, une commande contribuant à l’accroissement de la durée de vie des composants de puissance est tout d’abord proposée. Pour se faire, nous minimiserons sur chaque période le nombre de commutations des composants commandables à l’ouverture et à la fermeture. Cette idée a pour origine le fait qu’un convertisseur multiniveaux permet de générer le même niveau de tension de sortie à partir de plusieurs séquences de commutations différentes. Le principe de la commande proposée sera développé de manière générale, puis appliqué aux cas de structures type « Pont en H » à 5 niveaux, de type NPP (ou T-Type) et NPC. Ensuite, nous étudierons la continuité de service en mode nominal d’un convertisseur « Pont en H » à 5 niveaux, de type NPP (ou T-Type), suite à la défaillance en circuit ouvert d’un composant de puissance. Nous proposerons tout d’abord un diagnostic du défaut, constitué d’une première étape de détection, suivie d’une localisation précise du composant défaillant. Une topologie originale de convertisseur à tolérance de pannes permettra de garantir la continuité de service du système, en modifiant sa commande en adéquation avec le composant défaillant localisé. Des architectures électroniques numériques reconfigurables basées sur des composants FPGA (Field Programmable Gate Array) seront dédiées au diagnostic et à la reconfiguration de la commande ; elles permettront d’atteindre des performances temporelles élevées. L’ensemble des résultats présentés dans ce mémoire sera validé par modélisation/simulation, puis expérimentalement sur un banc de test / This thesis deals with continuity of service of multilevel power converters, during the failure of one of their power components. The studied converter topologies are the following, widely used in industrial applications: Neutral Point Clamped (NPC) and Neutral Point Piloted (NPP) or T-Type. First, to reduce the failure rate of the converter, an advanced control is proposed ; it increases the lifetime of the power components by minimizing the number of switchings over a period. This idea is based on the fact that a multilevel converter makes possible to generate the same output voltage level from several different switching sequences. The principle of the proposed control will be developed in a general way. Then, it is applied to the cases of 5-level "H-bridge" topologies, NPP (or T-Type) and NPC. Then, the continuity of service in nominal mode is studied for a 5 level "H-brige" NPP (or T-Type) converter, when an open circuit failure occurs on a power component. We first propose a fault diagnosis, consisting in a fault detection step, followed by the location of the faulty component. Then, an original fault-tolerant converter topology will ensure the continuity of service of the system, by modifying the control according to the localized faulty component. Reconfigurable digital electronic architectures based on Field Programmable Gate Array (FPGA) components will be dedicated to the diagnosis and the reconfiguration of the control; they will perform high temporal performances. All the results presented in this paper are validated by modeling and simulation. Then, they are experimentally validated on a test bench
124

Outils ensemblistes d'analyse et de synthèse des lois de commande robustes pour des systèmes incertains. / Invariant sets techniques for analysis and synthesis of robust control laws for uncertain systems

Luca, Anamaria 26 September 2011 (has links)
Le travail de recherche concrétisé par ce mémoire de thèse se trouve à l’intersection de deux domaines importants, la commande robuste des systèmes linéaires (LTI, LPV, en commutation) à temps discret affectés par des perturbations permanentes bornées et des contraintes et les ensembles invariants ellipsoïdaux maximal ou minimal. La première partie de ce mémoire se focalise sur l’analyse de la stabilité entrée-état (en anglais ISS) du système par rapport à une perturbation bornée et le calcul des ensembles invariants ellipsoïdaux minimal ou maximal (ou sous forme d’ellipsoïdes tronqués) satisfaisant les contraintes. La deuxième partie envisage la synthèse d’une commande par retour d’état ISS stable et robuste vis-à-vis de perturbations bornées, garantissant l’ellipsoïde invariant maximal satisfaisant les contraintes ; puis la synthèse d’une loi decommande par retour d’état et observateur ISS stable vis-à-vis de perturbations bornées, garantissant une certaine performance ; enfin la synthèse d’un paramètre de Youla afin de garantir la projection maximale sur le sous-espace de l’état initial. La projection obtenue possède alors un volume plus grand que celui obtenu sans le paramètre de Youla d’où une amélioration en termes de robustesse. Une dernière étape vise à obtenirun compromis entre la robustesse et la performance en utilisant des critères basés sur le placement de pôles ou sur la vitesse de décroissance de la fonction de Lyapunov. Tous les résultats théoriques obtenus sont exprimés sous forme d’inégalités matricielles et sont validés en simulation et de façon expérimentale dans le cadre de la commande d’un convertisseur de puissance. / The research concretized in this memory is located at the intersection of two important fields, the robust control of discrete-time linear systems (LTI, LPV, switched) affected by bounded disturbances and constraints and the ellipsoidal invariant sets theory.The first part of this memory focuses on the analysis of input-to-state stability (ISS) over a bounded perturbation and the computation of the maximal or minimal invariant ellipsoidal (or truncated ellipsoidal) set satisfying the constraints. The second part is considering the synthesis of a control state feedback law ISS stable and robust over bounded disturbances, ensuring the maximal ellipsoidal invariant set satisfying the constraints, then the synthesis of an observer-based control law ISS stable over bounded disturbances,ensuring a certain performance, and finally the design of a Youla parameter guaranteeing the maximal ellipsoidal projection on the initial state subspace. The resulting projection has a volume greater than the one obtained without the Youla parameter resulting an improvement in terms of robustness. A final step is to obtain a compromise between robustness and performance using criteria based on poles placement or on theLyapunov function decreasing rate. The theoretical results are expressed as matrix inequalities and are validated in simulation and and experimentally on a Buck DC-DC converter.
125

Contribution à la modélisation, l'analyse et l'optimisation de lois de commande pour convertisseurs DC-DC de puissance. / Contribution to modeling, analysis and control law optimization for DC-DC power converters

Jaafar, Ali 14 November 2011 (has links)
L'utilisation des convertisseurs de puissance pour des applications de la vie quotidienne devient de plus en plus importante. Les applications technologiques actuelles demandent simultanément un haut niveau de précision et de performance, ainsi les convertisseurs DC-DC ont un rôle très important dans les systèmes nécessitant la conversion et l’adaptation du niveau d'énergie. Nous nous intéressons dans le cadre des travaux de cette thèse à une analyse des approches de modélisation et de synthèse de loi de commande permettant d’assurer la stabilité et un certain niveau de performances dans l’ensemble du domaine de fonctionnement défini par un cahier des charges tout en prenant en compte la problématique de leur application dans un environnement industriel. L'objectif de nos travaux de recherche est donc de proposer des lois de commandes dont la synthèse est fondée sur une approche formalisé {modélisation + commande} en vue d’obtenir des lois de commande adaptées au point de fonctionnement. Les principes exploités sont fondés sur la commande et l’observation par modes glissants d’une part, et sur la théorie de passivité pour la synthèse des lois de commande, complétées par un couple {observateur d’état + estimateur de charge} dont la synthèse est fondée sur l’exploitation des principes d'immersion et invariance, d’autre part. Le souci de la validation expérimentale et de l’implantation des structures de commande avec du matériel disponible industriellement a été en permanence un fil conducteur. Pour démontrer l’efficacité des méthodes proposées, leur application expérimentale a été effectuée sur un convertisseur de type SEPIC. Ce convertisseur présente plusieurs avantages par rapport à autres convertisseurs. Cependant, il reste peu exploité, en dépit de ces avantages, en raison des difficultés pour obtenir des lois commande performantes permettant la stabilisation de sa tension de sortie dans tout l’ensemble du domaine de fonctionnement. / The use of power converters for real life applications is continuously increasing. Technological requirements include high precision levels and very good performances at the same time, where DC-DC converters have always played an important role in energy conversion-based systems. Our interest, throughout this thesis, is to analyze modeling and control law synthesis approaches in order to provide efficient control laws that are stable within the operating range, in response to certain specifications and also taking into account the problem of being industrially applicable. The aim of our research is hence to propose control law synthesis based on formalized {modeling + control} approaches, and adaptable to the operating point change. The exploited principles deal with Sliding Mode Observation and Control on one hand, and with the Passivity theory for control law synthesis coupled with the Immersion and Invariance principle for synthesizing {observers + load estimators} on the other. Also, the ease of implementing and validating the control law structures with common hardware available in the industry has always been a main issue throughout our study. In the view of illustrating the efficacy of the proposed methods, their experimental validation has been carried out on the SEPIC. This type of converter has many advantages compared to other converters. However, despite its advantages, it is still not well-exploited due to the difficulty in obtaining control laws capable of stabilizing its output voltage within a wide operating range.
126

Amélioration du rendement énergétique et de la dynamique d'entrée de convertisseurs d’énergie isolés par l’utilisation de techniques analogiques et numériques de commande / New switched mode power supply architectures capable of dealing with a wide input voltage range without a reduction of the power efficiency

Deniéport, Romain 17 December 2014 (has links)
Les travaux présentés ici proposent des convertisseurs d’énergie à haut rendement et très large dynamique de tension d’entrée, c'est-à-dire capables de fonctionner avec un rendement énergétique élevé sur une plage de tension d’entrée étendue (typiquement de 9V à 200V). De multiples tensions de réseaux sont standards dans l’industrie : elles sont spécifiques à un domaine (aéronautique, ferroviaire, …) et dépendent de la source primaire d’alimentation électrique (batterie d’accumulateurs, génératrice, …). Au sein d’un équipement embarqué, plusieurs réseaux peuvent cohabiter : une alimentation principale 110V et une alimentation de secours sur batterie 12V, par exemple. Le besoin de convertisseurs large dynamique d’entrée est donc une réalité, mais il n’existe sur le marché que peu de convertisseurs capables de réaliser une dynamique d’entrée supérieure à dix. Dans un premier temps, nous avons étudié les enjeux et les problématiques liés à la large dynamique d’entrée, afin de mieux cerner les limitations des topologies de puissance classiques. Nous avons ensuite traité le cas d’une architecture de conversion d’énergie de type série, dont nous avons amélioré le rendement énergétique grâce à l’utilisation de circuits d’aide à la commutation. Cette solution ayant des performances limitées, nous avons proposé de nouvelles architectures de convertisseurs DC/DC, de type parallèle, capables de supporter des dynamiques de tension d’entrée supérieures à vingt et ayant un rendement énergétique élevé (supérieur à 80%). Nous avons également étudié et mis en œuvre des stratégies de commande, numériques et analogiques, permettant de contrôler ces nouvelles topologies complexes. / Power converters are present in virtually every embedded system, but many standards of DC networks exist: the supply voltage is depending on how the power is generated (battery, alternator …) and can range from 12V to more than 115V. When an equipment must comply with a 110V main supply and 12V back-up supply, the use of a wide input voltage range DC/DC converter is mandatory. Since classical switched mode power converters cannot achieve simultaneously high efficiency and wide input voltage range, manufacturers rarely propose DC/DC converters with an input voltage range greater than 10. This work tackles the issue of wide input voltage power conversion. After discussing about designs trade off and problems that stem from a wide input range, we try to improve the overall efficiency of a classical buck-boost converter, by using non dissipative switching-aid circuits. We also proposed a novel two stages power converter capable of dealing with very wide input voltage ranges (more than 20), without a reduction of the power efficiency. Since those new converters are far more difficult to control, some theoretical analysis was performed and some practical tests were done using complex controls laws.
127

Conception d'un convertisseur de puissance pour véhicules électriques multi-sources / Designing a power converter for electric vehicles multi-source

Boucherit, Ahmed 16 December 2011 (has links)
L’utilisation des plusieurs sources d’énergies de caractéristiques différentes, à bord du véhicule électrique VE) nécessite l’adoption de convertisseurs statiques. Ces derniers peuvent avoir la fonction de conditionneur ’énergie des différentes sources et/ou commander les machines électriques du véhicule.Généralement les VE disposent d’un bus continu « de quelques centaines de volts » dont la stabilité est assurée par un groupe de convertisseurs élévateurs de tension (du fait que les sources ont généralement un niveau de tension faible ; quelques dizaines de volts). Lors des démarrages/arrêts très fréquents du VE en mode urbain, les sources pourraient alimenter directement le moteur de traction sans avoir recours aux convertisseurs élévateurs de tension. Afin d’exploiter cette fonctionnalité, nous proposons d’explorer une deuxième architecture de convertisseur basée sur l’adoption d’un niveau de tension variable du bus continu. Dans cette approche, la tension minimale de ce dernier est fixée en fonction des niveaux de tensions disponibles du côté des sources et de la vitesse requise (niveau des f.é.m du moteur de traction). Ainsi, le rapport variable d’élévation de la tension est minimal à faible vitesse du véhicule en mode urbain et il est maximal à grande vitesse, en modes route et autoroute. Ceci apportera une amélioration du rendement énergétique de l’ensemble sources-moteurs notamment en mode urbain. Par ailleurs, l’utilisation grand public de ces véhicules exige des contraintes maximales de disponibilité (continuité de service) des fonctions principales notamment l’alimentation embarquée. A travers le travail de cette thèse nous proposons une nouvelle topologie du convertisseur de puissance entre les sources (une Pile à combustibles associée à un pack de super-condensateurs) et les charges (moteur de traction et réseau de bord alimentant les auxiliaires du véhicule). Ce convertisseur adopte une tension variable du bus continu et une redondance de l’alimentation du moteur de traction. Après la présentation du convertisseur proposé et son positionnement par rapport à la littérature, une analyse du fonctionnement et la modélisation de sa partie DC-DC est détaillée notamment à travers des résultats de simulation de ses différents modes. A ce titre un programme de simulation fine (à l’échelle des impulsions de commande) du système entier a été développé. Dans un deuxième temps, la commande automatique et rapprochée des interrupteurs de puissance a été développée en se basant respectivement sur la méthode de contrôle par petits signaux et la commande hystérésis de courant, triangulaire-rapport cyclique et triangulaire-sinus. Les résultats de simulation des fonctionnalités principales attendues mettent en évidence la faisabilité de l’architecture du convertisseur de puissance proposée. Enfin, une maquette expérimentale à échelle réduite a été développée dans le but de valider l’étude théorique. Les premiers tests expérimentaux de la partie DC-DC du convertisseur donnent des résultats satisfaisant et valident ainsi le processus de conception. Le travail futur sera la réalisation d’une maquette à échelle 1 dans laquelle la conception du refroidisseur sera intégrée en amont de la réalisation du plan de masse dudit convertisseur. Nous pensons que cela permettra une meilleure optimisation de l’espace à bord du véhicule et améliorera le rendement énergétique de la chaine de traction. / The use of many energy sources of different kind in a electrical vehicle (EV) needs the adoption of static converters. These can have the function of either conditioning energy or driving the electrical machines of the vehicle. EV’s generally have a DC bus of some hundred volts, whose stability is ensured by a set of boost converters, since the voltage level of the several sources is as low as about some tens of volts. During frequent start/stop phases of EV’s in urban mode, energy sources can feed the motors directly without using the converters. On the basis of this consideration this thesis proposes a novel converter topology adopting a variable DC voltage level. In this approach the lowest level of the DC bus is determined as a function of the voltages available from the sources and of the required speed (back fem of the traction motor). In this way the variable step-up voltage ratio is minimal at low speeds of the EV in urban mode and maximal at higher speeds in motorway modes. This would result in an energy efficiency improvement of the sources-motors system, especially in urban mode. On the other hand the use of this EV demands some constraints as for the service continuity of the main functions of the EV, particularly the energy supply.This thesis proposes a novel power converter topology between the sources (a Fuel Cell System associated with a pack of Super-capacitors) and the loads ( traction motor and auxiliary supply system). This converter adopts a variable DC bus voltage and a redundant supply of the traction motor. After presenting the proposed converter in the framework of the state of the art, the analysis and modelling of its DC/DC part is presented, especially with simulation results of the different modes of operation. With this regard a complete simulation program has been developed down to the scale of switching pulses. Afterwards the control of the power devices has been developed by using the small signal control and the hysteresis control, triangular duty cycle and triangular sine. The simulation results of the main modes show the feasibility of the proposed power converter architecture. Finally an experimental rig has been set up, at reduced scale, for assessing the theoretical analysis. The experimental results of the DC/DC part yield satisfactory results thus proving the effectiveness of the design. Future work will focus on setting up e real scale converter, where the cooling system design will be added before realizing the mass board of the converter. This should lead up to the optimization of the volume occupied in the EV and to the improvement of the energy efficiency of the traction chain.
128

Rayonnement des convertisseurs statiques. Application à la variation de vitesse.

Aimé, Jérémie 13 March 2009 (has links) (PDF)
Les commutations au sein des convertisseurs statiques, base même du transfert d'énergie sont à l'origine des perturbations électromagnétiques. En effet des fronts raides engendrent des signaux en mode commun qui excitent les câblages, les structures métalliques ou encore les composants passifs. Ces éléments, de par leurs dimensions importantes jouent alors le rôle d'antennes émettrices rayonnant l'énergie perturbatrice dans l'environnement immédiat du produit et susceptible de produire des dysfonctionnements au sein d'autres équipements. L'objet de cette travail de thèse est de quantifier et de modéliser les différentes sources d'énergie en fonction de leur intensité vis-à-vis d'une gamme de fréquences donnée dans un premier temps, puis dans un second temps de montrer que des actions astucieuses et peu onéreuses notamment sur les câblages ou les routage astucieux peuvent permettre de diminuer grandement les perturbations engendrées par l'écoulement des courants de mode commun en mode conduit mais surtout en mode rayonné. L'impact des blindages est aussi étudié en tout dernier ressort quand l'effort de réduction à la base n'est pas suffisant compte tenu des contraintes technologiques.
129

Nouvelles architectures distribuées de gestion et conversion de l'énergie pour les applications photovoltaïques

Petibon, Stephane 20 January 2009 (has links) (PDF)
Les recherches actives sur les matériaux photovoltaïques et sur les systèmes de gestion de cette énergie sont à la base de ces progrès constants. Le LAAS travaille depuis plusieurs années dans cette optique d'amélioration et d'optimisation de l'énergie électrique produite par les systèmes solaires photovoltaïques. L'insertion d'un étage d'adaptation entre un générateur photovoltaïque (PV) et une charge optimise le transfert d'énergie. Ainsi, cet étage, commandé par une MPPT (Maximum Power Point Tracking), permet de rechercher en permanence le point maximum de puissance délivré par le module PV. Afin d'accroître encore les performances énergétiques des systèmes solaires, cette thèse s'est délibérément orientée vers une architecture fortement distribuée. Cette approche, consistant à répartir la gestion du générateur PV, permet de se rapprocher au plus près de la production photovoltaïque et ainsi en optimiser la puissance électrique globalement produite. Pour cela, nous avons développé des prototypes de micro-convertisseurs dédiés aux applications faibles puissances photovoltaïques. Les mesures journalières effectuées nous ont permis d'étudier avec précision l'intérêt de l'architecture distribuée et d'obtenir des résultats de validation montrant les perspectives à venir. Plusieurs solutions d'architectures se dégagent avec différents bilans des gains énergétiques qu'elles apportent.
130

Variateur de vitesse à impact électromagnétique réduit : onduleur multiniveaux et nouvelles stratégies de modulation

Videt, Arnaud 01 December 2008 (has links) (PDF)
Parmi les convertisseurs d'électronique de puissance, les variateurs de vitesse utilisés pour l'alimentation des machines électriques sont source de perturbations électromagnétiques à haute fréquence telles que les courants de mode commun et les surtensions aux bornes des moteurs. Le travail porte sur la réduction de ces perturbations par l'emploi d'un convertisseur multiniveaux associé à de nouvelles lois de commande rapprochée. Après un état de l'art des méthodes d'atténuation existantes, l'onduleur à trois niveaux de type neutral-point-clamped (NPC) est retenu comme structure de conversion continu-alternatif et une nouvelle stratégie de modulation de largeur d'impulsion (MLI) est développée en vue de réduire les courants de mode commun générés par l'onduleur. Les phénomènes entrant en jeu dans les commutations des interrupteurs de puissance sont analysés et modélisés afin d'établir des contraintes de commande permettant de maximiser les performances de la MLI proposée. Parallèlement, l'utilisation de câbles longs entre le variateur et la machine soulève une contrepartie vis-à-vis des surtensions moteur qui est maîtrisée par l'exploitation adéquate des degrés de liberté de la nouvelle MLI. Enfin, la problématique de régulation du point milieu capacitif du bus continu est abordée. La stratégie proposée est implantée expérimentalement par l'intermédiaire d'une modulation naturelle par porteuses, et les résultats de mesure montrent un gain de cinq décibels sur les courants de mode commun par rapport aux stratégies classiques tout en limitant les surtensions générées aux bornes du moteur et en assurant l'équilibrage du bus continu.

Page generated in 0.1198 seconds