• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 12
  • 12
  • 12
  • 12
  • 11
  • 1
  • 1
  • Tagged with
  • 73
  • 30
  • 27
  • 22
  • 17
  • 13
  • 11
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação da confiabilidade e modo de falha de coroas cerâmicas em função do módulo de elasticidade dos endentadores / Effect of indenter material on reliability of all-ceramic crowns

Fabio Cesar Lorenzoni 03 May 2013 (has links)
A incompatibilidade entre o módulo de elasticidade (E) do endentador e dos materiais cerâmicos durante os testes de fadiga tem gerado controvérsias. Foram testadas as hipóteses que coroas totalmente cerâmicas apresentarão confiabilidade à fadiga acelerada progressiva do tipo step-stress (hipótese 1) e modos de falha (hipótese 2) similares, quando dois endentadores, um à base de carboneto de tungstênio (WC, E = 600 GPa) e outro de cerâmica esteatite [SB, E = 90 GPa] forem utilizados para transferir a carga. Para avaliar o efeito dos endentadores, um preparo para coroa total em um molar inferior foi realizado. A partir deste modelo mestre, 42 coroas à base de Y-TZP e 42 réplicas em resina composta foram produzidas. As réplicas em resina foram envelhecidas por 30 dias. Todas as coroas foram cimentadas sobre estas réplicas com cimento autoadesivo (Rely X Unicem - 3M/ESPE, St. Paul, EUA) e divididas em dois grupos de acordo com o endentador (WC ou SB). As coroas foram submetidas tanto ao teste de resistência à fratura (n = 3 por grupo), empregado para determinar os perfis de carga (leve, moderado e agressivo) quanto à fadiga (n = 18 por grupo), utilizando um endentador novo para cada coroa. Impressões de todas as coroas e endentadores submetidos ao perfil leve foram obtidas, em pontos específicos do perfil (0, 40k, e, 80k 120k, 160k), vazadas com resina epóxi e avaliadas sob MEV, com a finalidade de inspecionar a morfologia e medir a área endentada. O Use level Probability mostrou sobreposição entre os intervalos de confiança, indicando que não houve diferença significante entre os grupos, independente do critério de falha. O módulo de Weibull Beta (&#x3B2;) calculado para IA (análise inicial) foi de 1,99 e 1,67 para SB e WC, respectivamente, apontando que a fadiga acelerou o fracasso em ambos os grupos. Este não foi o caso para os valores de &#x3B2; para a análise de FA (análise final) (SB = 1,1 e WC = 0,72), revelando que a carga pode ter influenciado sozinha o mecanismo de falha. Ambos os endentadores produziram padrões semelhantes de desgaste/danos nas coroas. A análise fractográfica revelou modos de falhas concorrentes, mas as trincas tipo cone parciais foram as mais dominantes em ambos os grupos. As medições das áreas endentadas mostraram diferença estatística entre os grupos (SB vs. WC) (p <0,05). No geral, o endentador WC exibiu área maior do que a produzida pelo SB. O endentador mais compatível (SB) com a superfície cerâmica produziu confiabilidade e modos de falhas semelhantes ao ser comparada com o WC; assim, as hipóteses 1 e 2 foram aceitas. / Concerns about elastic modulus (E) mismatch between indenter and ceramic materials during fatigue testing have generated controversy. We hypothesized that all-ceramic crowns will exhibit similar step-stress sliding contact fatigue reliability (hypothesis 1) and failure characteristics (hypothesis 2) when using high stiffness tungsten carbide (WC, E = 600 GPa) vs enamel like steatite (SB, E = 90 GPa) indenters. To evaluate the effect of indenters, a preparation for a full crown was made on a first lower molar. From this master die 42 Y-TZPveneered all-ceramic crowns and 42 tooth-resin réplicas were made. Crowns were cemented onto the aged (30 days) tooth-resin réplicas with self-adhesive resin-based cement (Rely X UniCem - 3M/ESPE, St. Paul, USA). After, crowns were divided into two groups according to indenter (WC or SB). Specimens were subject to single-load to fracture (n = 3 per indenter type) to determine the step-stress profiles (mild, moderate, and aggressive) and to mouthmotion step-stress fatigue-tested (n = 18 per indenter type). Two failure modes were determined (inital analysis [IA] and final analysis [FA]). For each crown, a new indenter was used and labelled accordingly for surface damage evaluation. Impressions from all crowns subjected to mild profile were taken following a pre-arranged number of cycles (0, 40k, 80k, 120k e, 160k), poured with epoxy resin and SEM evaluated to inspect the morphology and to measure the indented area. The use level probability plots of the fatigue data showed overlap between the 2-sided 90% confidence bounds. The calculated Weibull Beta (&#x3B2;) for IA was 1.99 and 1.67 for SB and WC, respectively, pointing out that fatigue accelerated the failure in both groups. This was not the case for the &#x3B2; values for the FA analysis (SB = 1.1 and WC = 0.72), revealing tha the load alone dicted the failure mechanism. Both indenters produced similar pattern of wear on crown surfaces. Fractographic landmarks showed competing failure modes, but partial cone cracks were the most dominant for both groups. The indented area measurements showed statistical difference between groups (SB vs WC) (p < .05). Overall, the WC indenter displayed the largest area than SB, except when 120k was taken into account. The more compliant SB indenter led to similar reliability and failure modes to WC (hypotheses 1 and 2 accepted).
32

Confiabilidade de coroas de dissilicato de lítio com diferentes espessuras sob fadiga / Reliability of lithium disilicate crowns with different thickness under fatigue

Leandro de Moura Martins 13 October 2011 (has links)
Para avaliar a confiabilidade à fadiga de coroas de dissilicato de lítio E.max CAD, com 1mm (monolítica) e 2mm de espessura, foi realizado um preparo para coroa total de um primeiro molar inferior com redução de 1 e 2mm. Réplicas em resina composta do preparo baseado em desenho auxiliado pelo computador (CAD) foram posicionadas em um articulador odontológico para fabricação dos corpos de prova. As coroas monolíticas de 1mm de dissilicato de lítio CAD/CAM (DLM) e coroas de 2.0mm, com 1,5mm de espessura vestibular de dissilicato de lítio CAD/CAM e recoberta com 0.5mm de porcelana (DLV), foram comparadas com coroas de zircônia (Y-TZP) e metalocerâmica (MC). As réplicas de resina composta foram envelhecidas em água por 30 dias e todas coroas cimentadas com cimento resinoso. Após cimentadas, todos os corpos de prova foram envelhecidos em água por 7 dias e testados com carga única ou com fadiga acelerada progressiva. As cargas foram posicionadas na cúspide mésiovestibular (n=21 para cada sistema cerâmico). A probabilidade Weibull e os gráficos de probabilidade (Alta Pro, Reliasoft) foram calculados (Best data fit QCP) e plotados. A evolução da trinca foi acompanhada e os espécimes analisados após o teste. A menor confiabilidade foi observada para o grupo Y-TZP e não houve diferença estatística entre o grupo MC, DLM e DLV. O grupo DLV demonstrou a maior resistência característica (Eta). O modo de fratura do grupo Y-TZP foi a fratura da porcelana de cobertura sem exposição da infraestrutura. O grupo MC apresentou fraturas da porcelana com exposição do metal. Enquanto os grupos DLM e DLV tiveram fraturas catastróficas. Os grupos DLM e DLV apresentaram uma resposta à fadiga semelhante à do grupo MC e melhor que o grupo Y-TZP. / To evaluate the fatigue reliability of monolithic 1mm and thinly veneered 2mm E.max CAD crowns. A preparation reduction of 1 and 2mm for a full crown was made on a first lower molar. The CAD-based preparation was replicated and positioned in a dental articulator for specimen fabrication. Monolithic 1mm lithium disilicate CAD/CAM crowns (DLM) and a 2mm lithium disilicate CAD/CAM with 1.5 mm thick at buccal aspect veneered with 0.5 mm thick of porcelain were compared to zirconia based (Y-TZP) and metaloceramic (MC) crowns. All composite dies were 30-day aged and all crowns were resin cemented to composite dies. After luting, all specimens were aged for 7 days in water and either single loaded to failure or step-stress fatigue tested. Loads were positioned on mesial-buccal cusp (n=21 for each ceramic system). Probability Weibull and Use level probability curves (Alta Pro, Reliasoft) were calculated (Best data fit QCP) and plotted. Crack evolution was followed and specimens were analyzed postmortem. Lower reliability was observed for Y-TZP group and no statistical difference was observed between MC and DLM e DLV groups. DLV group showed the highest characteristic strength (Eta). Fracture mode for Y-TZP group was veneer chipping without core exposition. MC fractures were mostly chipping with metal coping exposure. While the failure for DLM and DLV groups were bulk fracture. Groups DLM and DLV resulted in fatigue response of lithium disilicate comparable to MC and higher than Y-TZP.
33

Estudo espectroscópico de sistemas homonucleares de íons lantanídeos com os ligantes 18-coroa-6 e 2,3-bis(2-piridil)pirazina

TAVARES, Andreza Ribeiro 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T22:59:59Z (GMT). No. of bitstreams: 2 arquivo4320_1.pdf: 763645 bytes, checksum: 4975bda035f0e72bf0e6bbbda5cc358d (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / As propriedades fotofísicas dos íons lantanídeos têm motivado a busca por novos ligantes que possuam uma maior eficácia no processo de transferência de energia, contribuindo, portanto, para elevados rendimentos quânticos de emissão. A excitação direta dos íons é dificultada por causa da sua baixa absortividade molar, decorrente da natureza proibida das transições 4f-4f. A escolha de um ligante apropriado é muito importante para os processos luminescentes. Neste trabalho, os ligantes macrocíclicos (oligoéteres) chamados éteres coroa, especificamente, o 18-coroa-6, foi usado na síntese de compostos de coordenação precursores com Eu (III), Tb (III) e Gd (III). Com o interesse em remover moléculas de água, na primeira esfera de coordenação, utilizou-se o 2,3-bis(2-piridil)pirazina (2,3-dpp). Todos os complexos foram caracterizados por análise elementar e por métodos espectroscópicos (ultravioleta e infravermelho). O espectro de emissão de [Eu(18C6)(2,3-dpp)]Cl3 apresentou anormalidade da transição 5D0&#8594;7F4, indicando que o mesmo apresenta um ambiente de mais alta simetria em torno do íon Ln3+. Com a substituição das moléculas de água, houve um aumento na intensidade de luminescência, ficando evidenciado através dos cálculos das taxas radiativas
34

Éteres coroa com íons lantanídeos: de compostos de coordenação a novos materiais nanoestruturados de sílica

BELIAN, Mônica Freire 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:13:53Z (GMT). No. of bitstreams: 2 arquivo4285_1.pdf: 5598762 bytes, checksum: 3b5f8206d207fcc11a2c2dc1c25982ed (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Com o objetivo de desenvolver novos materiais e ligantes, baseados em éteres coroa, capazes de coordenarem um ou mais íons lantanídeos, o presente trabalho mostra a síntese de compostos de coordenação mono e binucleares, livres ou ligados às matrizes de sílica. As caracterizações foram realizadas via análise elementar, análise termogravimétrica, espectroscopia na região do infravermelho e ultravioleta, ressonância magnética nuclear de 1H e 13C. Um estudo minucioso, acerca dos compostos inéditos sintetizados, mostrou a necessidade da substituição das moléculas de água (1a esfera de coordenação) por ligantes heterobi(tri)aris (bipiridina, fenantrolina e terpiridina); esses bem descritos na literatura, geralmente otimizam o processo de luminescência. Os dados de análise elementar (experimentais e teóricos) dos compostos sintetizados apresentaram boa concordância; confirmando assim, as fórmulas mínimas propostas. Os dados da espectroscopia na região do ultravioleta e infravermelho corroboraram para intuir que os ligantes encontram-se coordenados aos íons lantanídeos. A espectroscopia de luminescência, para os compostos de coordenação, mostrou que os sistemas mononucleares apresentam maior intensidade de luminescência quando comparados aos binucleares e às matrizes de sílica. Apenas o sistema NanoSilTb apresentou intensa luminescência, podendo ser aplicado como dispositivo molecular conversor de luz. Para os complexos de gadolínio (III), foram determinados os estados tripletos, oriundos dos ligantes, através de medidas de fosforescência. A partir de um diagrama de níveis de energia, o qual possue valores de tripletos, pode-se entender alguns fenômenos observados experimentalmente, como a baixa luminescência apresentada pelos complexos binucleares (sem ligantes heterocíclicos), bem como a emissão dos ligantes nos complexos de térbio. Os parâmetros R02 mostraram que o complexo [Eu(15-coroa-5)(bip)(H2O)]Cl3 apresentou o maior valor, indicando que este apresenta um campo ligante forte (maior mistura nos J s), os maiores valores apresentados dos parâmetros de intensidades (&#937;&#955;) foi do complexo [Eu(15-coroa- 5)(fen)2]Cl3, mostrando que neste caso o íon encontra-se em uma ambiente mais polarizável. Apesar dos complexos apresentarem em sua estrutura os éteres cora, os valores de eficiência quântica variaram de 71% a 13,6 %, indicando que esses podem ser utilizados na geração de sistemas luminescentes
35

Análise da distribuição das tensões nas estruturas de suporte de overdentures, rebordo residual e implantes, com sistema de conexão de coroas cônicas (Syncone-Dentsply). / Analysis of the tensions distribution in the structures of overdentures support, residual alveolar ridge and implants, with connection of conical crowns system (Syncone-Dentsply)

Guariglia, Ana Cristina Aurora Rosa Perasso 22 March 2007 (has links)
O sistema de osseointegração desenvolvido por Branemark revolucionou o campo das reabilitações protéticas, incentivando os profissionais a indicar e realizar próteses do tipo overdentures. Estes dispositivos representam uma ótima alternativa para solucionar os problemas dos pacientes desdentados, insatisfeitos por diversos fatores. Várias são as associações entre os implantes e os sistemas de conexões empregados em overdentures. A literatura e a prática clínica fazem observar que na dependência do sistema de conexão empregado, há uma diferença no comportamento biomecânico, realizado por este conjunto: prótese/implante/conexão. Desta forma, é importante analisar como as tensões se distribuem sobre as estruturas que suportam estas cargas, uma vez que não existe o ligamento periodontal ao redor dos implantes que promove o mecanismo fisiológico, natural nos dentes. Assim, o objetivo desta investigação foi de avaliar, com o auxílio do método fotoelástico, o comportamento da distribuição das tensões em sobredentaduras (overdentures), suportadas por quatro implantes Ankylos®/ Dentsply®, utilizando-se o sistema protético de conexão de coroas cônicas Syncone®/ Dentsply®, onde se comparou duas formas de distribuição dos implantes, na primeira (CPM1) os implantes foram posicionados nas regiões de incisivos centrais e pré-molares e o segundo (CPM2) os implantes estavam posicionados nas regiões de caninos e pré-molares. Os modelos receberam cargas de forma crescente de 0,0 a 9,0 kg e, as tensões resultantes nas estruturas de suporte, foram analisadas fotoelasticamente. De acordo com a metodologia empregada nesta pesquisa, somos levados a concluir que: 1) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre quatro implantes, sendo 2 localizados na região de incisivos centrais e 2 situados, diametralmente opostos, na região de segundos pré-molares na mandíbula - CPM1 - o rebordo residual é quem recebe a maior quantidade de tensões em relação aos implantes; 2) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre 4 implantes, dispostos 2 a 2, bilateralmente e diametralmente opostos, nas regiões de caninos e pré-molares, na mandíbula (CPM2), as maiores tensões são transmitidas ao rebordo residual, sendo que os implantes suportes resultam mais preservados; 3) Comparativamente, o CPM2, aparenta ter transmitido menores tensões aos implantes que o CPM1; 4) Os implantes são preservados quanto à ocorrência de uma sobrecarga, durante a máxima intercuspidação dos arcos dentários, quando se emprega o sistema Syncone® associado à overdenture ou sobredentadura. / The osseo-integrated system develop by Branemark has revolutionized the prosthetic rehabilitation field, encourage the professionals to indicate and perform prostheses like overdentures. These devices represent an optimal alternative to solve the full dentures patient?s problems, dissatisfied for diverse factors. There are several associations between implants and prosthetic connectors employees for overdentures. The literature and the clinic practice may observe that according of the connection system employed, there is a difference into the biomechanical behavior, realized for this set: prostheses/implant/connection. From this forms, it is important to analyze how the tensions are distributing on the structures subject that support these loads, since it doesn\'t exist the periodontal ligament around the implants, what promotes the physiological mechanism of the natural teeth. Such, the purpose from this investigation was appraising, with the aid of the photoelastic method, the distribution way from the tensions at the overdentures, supported by four implants Ankylos®/ Dentsply, by using the prosthetic system of connection of conic crowns ? Syncone®/ Dentsply, were applied loads from 0,0 to 9,0kg, in crescent forms and, the tensions resulting on the support structures, have been analyzed by the photoelasthic method. Where two forms of distribution of the implantations were compared, first (CPM1) the implants were located at the regions of the central incisors and pre-molar, and as (CPM2) the implants were located at the regions of canines and pre-molar. The models had received loads of increasing form, from 0,0 to 9,0 kg and, the resultant tensions in the support structures, had been analyzed by the photoelastic method. In agreement with the methodology used in this research, we are led to conclude that: 1) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, being 2 located in the region of central incisors and 2, diametrical opposing ones, in the region of the second pre-molar (CPM1) the residual alveolar ridge is who receives the biggest amount of tensions in relation to the implants; 2) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, bilaterally and diametrical opposing ones, in the regions of canine and pre molar (CPM2), the biggest tensions were transmitted to the residual alveolar ridge, being the implants supports resulted more preserved; 3) Comparatively, the CPM2, seems to have transmitted less tensions to the implants than the CPM1; 4) The implants were preserved as the occurrence of an overload, during the maximum intercuspidação of the dental arcs, when the overdenture associated with Syncone® system has been used.
36

Análise da distribuição das tensões nas estruturas de suporte de overdentures, rebordo residual e implantes, com sistema de conexão de coroas cônicas (Syncone-Dentsply). / Analysis of the tensions distribution in the structures of overdentures support, residual alveolar ridge and implants, with connection of conical crowns system (Syncone-Dentsply)

Ana Cristina Aurora Rosa Perasso Guariglia 22 March 2007 (has links)
O sistema de osseointegração desenvolvido por Branemark revolucionou o campo das reabilitações protéticas, incentivando os profissionais a indicar e realizar próteses do tipo overdentures. Estes dispositivos representam uma ótima alternativa para solucionar os problemas dos pacientes desdentados, insatisfeitos por diversos fatores. Várias são as associações entre os implantes e os sistemas de conexões empregados em overdentures. A literatura e a prática clínica fazem observar que na dependência do sistema de conexão empregado, há uma diferença no comportamento biomecânico, realizado por este conjunto: prótese/implante/conexão. Desta forma, é importante analisar como as tensões se distribuem sobre as estruturas que suportam estas cargas, uma vez que não existe o ligamento periodontal ao redor dos implantes que promove o mecanismo fisiológico, natural nos dentes. Assim, o objetivo desta investigação foi de avaliar, com o auxílio do método fotoelástico, o comportamento da distribuição das tensões em sobredentaduras (overdentures), suportadas por quatro implantes Ankylos®/ Dentsply®, utilizando-se o sistema protético de conexão de coroas cônicas Syncone®/ Dentsply®, onde se comparou duas formas de distribuição dos implantes, na primeira (CPM1) os implantes foram posicionados nas regiões de incisivos centrais e pré-molares e o segundo (CPM2) os implantes estavam posicionados nas regiões de caninos e pré-molares. Os modelos receberam cargas de forma crescente de 0,0 a 9,0 kg e, as tensões resultantes nas estruturas de suporte, foram analisadas fotoelasticamente. De acordo com a metodologia empregada nesta pesquisa, somos levados a concluir que: 1) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre quatro implantes, sendo 2 localizados na região de incisivos centrais e 2 situados, diametralmente opostos, na região de segundos pré-molares na mandíbula - CPM1 - o rebordo residual é quem recebe a maior quantidade de tensões em relação aos implantes; 2) Quando se associa o sistema Syncone® com overdenture ou sobredentadura, apoiada e retida sobre 4 implantes, dispostos 2 a 2, bilateralmente e diametralmente opostos, nas regiões de caninos e pré-molares, na mandíbula (CPM2), as maiores tensões são transmitidas ao rebordo residual, sendo que os implantes suportes resultam mais preservados; 3) Comparativamente, o CPM2, aparenta ter transmitido menores tensões aos implantes que o CPM1; 4) Os implantes são preservados quanto à ocorrência de uma sobrecarga, durante a máxima intercuspidação dos arcos dentários, quando se emprega o sistema Syncone® associado à overdenture ou sobredentadura. / The osseo-integrated system develop by Branemark has revolutionized the prosthetic rehabilitation field, encourage the professionals to indicate and perform prostheses like overdentures. These devices represent an optimal alternative to solve the full dentures patient?s problems, dissatisfied for diverse factors. There are several associations between implants and prosthetic connectors employees for overdentures. The literature and the clinic practice may observe that according of the connection system employed, there is a difference into the biomechanical behavior, realized for this set: prostheses/implant/connection. From this forms, it is important to analyze how the tensions are distributing on the structures subject that support these loads, since it doesn\'t exist the periodontal ligament around the implants, what promotes the physiological mechanism of the natural teeth. Such, the purpose from this investigation was appraising, with the aid of the photoelastic method, the distribution way from the tensions at the overdentures, supported by four implants Ankylos®/ Dentsply, by using the prosthetic system of connection of conic crowns ? Syncone®/ Dentsply, were applied loads from 0,0 to 9,0kg, in crescent forms and, the tensions resulting on the support structures, have been analyzed by the photoelasthic method. Where two forms of distribution of the implantations were compared, first (CPM1) the implants were located at the regions of the central incisors and pre-molar, and as (CPM2) the implants were located at the regions of canines and pre-molar. The models had received loads of increasing form, from 0,0 to 9,0 kg and, the resultant tensions in the support structures, had been analyzed by the photoelastic method. In agreement with the methodology used in this research, we are led to conclude that: 1) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, being 2 located in the region of central incisors and 2, diametrical opposing ones, in the region of the second pre-molar (CPM1) the residual alveolar ridge is who receives the biggest amount of tensions in relation to the implants; 2) When the overdenture is associated with Syncone® system, supported and retained by 4 implants, bilaterally and diametrical opposing ones, in the regions of canine and pre molar (CPM2), the biggest tensions were transmitted to the residual alveolar ridge, being the implants supports resulted more preserved; 3) Comparatively, the CPM2, seems to have transmitted less tensions to the implants than the CPM1; 4) The implants were preserved as the occurrence of an overload, during the maximum intercuspidação of the dental arcs, when the overdenture associated with Syncone® system has been used.
37

Análise biomecânica de resistência à fratura em dentes caninos artificiais de cães, com restauração metálica fundida e retentores intrarradiculares retos e curvos com núcleo - Estudo comparativo com análise por elementos finitos / Biomechanical analysis of resistance to fracture in artificial dog canine teeth with cast metal restoration and straight and curved intrarradiculares retainers with core - Comparative study with finite element analysis

Camargo, Sergio Luiz da Silveira 11 March 2016 (has links)
Os cães, por fatores diversos, acabam por apresentar dentes fraturados com ou sem exposição de polpa. Estas fraturas basicamente são identificadas como fraturas recuperáveis não complicadas, recuperáveis complicadas ou irrecuperáveis. As fraturas recuperáveis (localizadas apenas no esmalte e dentina) são tratadas com dentística restauradora. As recuperáveis complicadas (com lesões em esmalte, dentina e exposição do canal radicular) passam por tratamento endodôntico, podendo ser seguidas de restaurações metálicas. Os dentes mais comumente acometidos são os dentes caninos, superiores ou inferiores. Este trabalho em dentes artificiais simulando considerável destruição de sua porção coronal objetivou testar, após a adaptação da restauração metálica fundida, a resistência às fraturas no dente canino. Os dentes artificiais foram padronizados com uma técnica de replicação de raízes artificiais em molde de resina acrílica quimicamente ativada. Oitenta réplicas iguais de resina composta fotopolimerizável, padronizadas em tamanho e forma, foram construídas a partir desta técnica. Antes da reconstrução protética, aplicou-se o tratamento endodôntico, desobturação, preparo do canal radicular e moldagem. Proteticamente, um pino intrarradicular reto e outro curvo, ambos com núcleo para sustentar a coroa metálica fundida foram cimentados na porção coronal de cada raiz-réplica. Os núcleos e coroa metálica foram ambos ferulados ou estojados. Avaliou-se os dois tipos de restauração com pino intrarradicular curvos ou retos cimentados com cimento de fosfato de zinco ou resinoso para identificar o melhor conjunto restaurador. Os testes de resistência biomecânica de 80 raízes-réplicas foram divididos em 4 grupos com 20 corpos de prova para cada um dos grupos. Grupo 1: das raízes-réplicas com pino intrarradicular curvo cimentados com cimento resinoso. Grupo 2: das raízes-réplicas com pino intrarradicular curvo cimentados com cimento de fosfato de zinco. Grupo 3: das raízes-réplicas com pino intrarradicular reto cimentados com cimento resinoso. Grupo 4: das raízes-réplicas com pino intrarradicular reto cimentados com cimento de fosfato de zinco. Estes grupos foram submetidos a teste de força com pré-carga de 1,5 N, com velocidade de avanço constante de 0,05 mm por minuto em ponto pré- determinado (mésio-lateral vestibularizada) até ocorrência de fratura do conjunto ou parte dele em uma Máquina Universal Kratos. Com a avaliação biomecânica e estudo estatístico de Kruskall-Wallis, identificou-se que os dados obtidos não seguiram distribuição normal. Esta diferença mostrou-se com o p<0,05 na interpretação do teste. No caso de dados não paramétricos o post-hoc do Kruskal-Wallis foi o teste de U de Mann-Withney. Paralelamente, um estudo com análise de elementos finitos comparou os resultados obtidos. Não houve diferença significativa sobre o tipo de cimento utilizado ou que favorecesse o uso do pino reto ou do pino curvo, recaindo a escolha para o operador decidir de acordo com a melhor indicação para cada caso clínico / The dogs, by various factors, present fractured teeth with or without pulp exposure. These fractures are basically identified as recoverable fractures not complicated, recoverable complicated or unrecoverable. Recoverable fractures (located just on enamel and dentin) are treated with restorative dentistry. The complicated recoverable (with lesions in enamel, dentin and exposure of the root canal) need to undergo endodontic treatment, and may be followed by metallic restorations. The teeth most commonly affected are the canine teeth, upper or lower. This work on artificial teeth simulating considerable destruction of their coronal portions aimed to test, after the adaptation of the cast metal restoration, the fractures in the canine teeth. Artificial teeth were standardized with an artificial root replication technique in acrylic chemically activated resin impression. Eighty equal photopolimerized composite resin replicas, standardized in size and shape, were built with this technique. Before the prosthetic reconstruction, endodontic treatment, desobturation, root canal preparation and molding were done. Protetically an intrarradicular straight pin and another curved one, both to sustain core fused metal crown were cemented over the crown of each root replica. The cores and metal crown were both belted or sheathed. It was evaluated the two types of restorations with intrarradicular curved or straight pin cemented with zinc phosphate cement or resin to identify the best restorative set. The biomechanical resistance tests applied over the 80 replica roots were divided into 4 groups with 20 samples for each of the groups. Group1: roots with intrarradicular curved pin replicas cemented with resin cement. Group 2: roots with intrarradicular curved pin replicas cemented with zinc phosphate cement. Group 3: roots intrarradicular straight pin replicas cemented with resin cement. Group 4: roots intrarradicular straight pin replicas cemented with zinc phosphate cement. These groups were submitted to the test of strength with 1.5 N preload force, with constant speed rate of 0.05 mm per minute in a predetermined point (mesio-vestibular) until occurrence of fracture of the whole set or part of it in a Universal Machine Kratos. The Biomechanical evaluation and statistical study of Kruskall-Wallis, identified that the data obtained did not follow normal distribution. That difference showed up with the p < 0.05 in the interpretation of the test. In the case of parametric data post-hoc Kruskal-Wallis test of U of Mann-Whitney. At the same time, a study with finite element analysis compared the results obtained. There was no significant difference on the type of cement used or favoring the use of straight or curved intrarradicular pin, therefore it is up to the surgeon to decide according to the best indication for each clinical case
38

Deformações geradas no intermediário e região peri-implantar após aplicação de cargas inclinadas em coroas unitárias

Albarracín, Max Laurent 31 July 2015 (has links)
A reabilitação protética de pacientes desdentados é uma área da Odontologia amplamente estudada por pesquisadores do mundo todo, e com o desenvolvimento dos implantes osseointegrados surgiram muitas perguntas sobre o desempenho das próteses instaladas sobre estes. Conhecer o comportamento mecânico do conjunto coroa unitária, intermediário, implante e tecido de suporte é importante para entender o processo de transmissão de forças e suas consequências, processos estes que ainda não estão totalmente compreendidos. O objetivo deste trabalho foi verificar a deformação gerada no intermediário e no osso peri-implantar após aplicação de uma carga inclinada sobre coroas unitárias metalocerâmicas. Foi utilizado um modelo mestre de poliuretano, simulando o osso mandibular, com um implante hexágono externo de 3,75mm x13 mm de comprimento, no qual foi fixado um intermediário multi-unit. O trabalho foi realizado com 3 grupos de 4 coroas cada, divididos de acordo com o tipo de cilindro e liga de fundição (cilindros de ouro sobrefundidos com liga de PdAg, cilindro de acrílico fundido com liga de NiCoCr e cilindros de CoCr usinado sobrefundidos com liga de NiCoCr). Cada corpo de prova foi submetido cinco vezes à aplicação de carga oblíqua de 15 e 30 graus no centro da oclusal de cada coroa com uma força de 300N em uma máquina universal de ensaios. Foram realizadas leituras das deformações geradas no intermediário e no poliuretano, com o uso de extensômetros lineares elétricos (strain gauges) os quais foram colados em três faces do intermediário (Disto lingual, Mesio lingual, Vestibular) e nas superfícies mesial, vestibular, distal e lingual do osso simulado ao redor do implante. Os dados obtidos foram submetidos à análise de variância a 3 critérios (ANOVA) e o teste de Tukey, utilizando um nível de significância (p<0,05). Os resultados mostraram que entre as duas angulações utilizadas existiram diferenças estatísticas significantes. Os valores médios de deformação se mantiveram dentro dos padrões de normalidade, na janela fisiológica descrita por Frost entre 50 &#x3BC;&#x3B5; e 1500 &#x3BC;&#x3B5; independente do tipo de cilindro utilizado, com exceção dos valores de compressão obtidos na carga oblíqua de 30 graus onde nos três tipos de cilindro ultrapassaram a janela de sobrecarga patológica com mais de 4000 &#x3BC;&#x3B5. / The prosthetic rehabilitation of edentulous patients is a dental area widely studied by worldwide researchers, and through the development of dental implants, appear many questions about the performance of prostheses installed on them. Knowledge of the mechanical behavior of the integration between single crown, abutment, implant and support tissue is very important to understand the forces transmission process and its consequences but these processes are not fully understood. The objective of the present study was to evaluate the deformation generated in the abutment and simulated peri-implant bone after application of an oblique load on metal-ceramic crowns. A polyurethane master model was used to simulate the jawbone with an implant external hexagon 3.75 mm x13 mm length, which was fixed in a multi-unit abutment. The study was conducted with twelve metal ceramic crowns divided according to type of cylinder and casting alloy, Group 1: Gold cylinder cast with PdAg alloy; Group 2: Acrylic cylinder cast with NiCoCr alloy; Group 3: CoCr cylinder cast with NiCoCr alloy, thus forming three groups of four sample each. Each specimen was subjected five times the application of oblique load of 15 and 30 degrees in the center of the occlusal of each crown with a 300N force in a universal testing machine. Readings were taken of the deformations generated in the abutment and bone simulated by polyurethane, with the use of electric linear strain gauges which have been positioned on three sides equidistant to each other to measure microstrains at abutment (disto-lingual, meso-lingual, Vestibular) and the simulated bone around each implant received four strain gauges, positioned on the mesial, distal, buccal and lingual aspects. The data were submitted to analysis of variance to 3 criteria (ANOVA) and Tukey test, using a significance level (p <0.05). The results showed that between the two angles tested there were significant statistical differences. The deformation average values remained within normal limits, at the adapted state described by Frost between 50 &#x3BC;&#x3B5 and 1500 &#x3BC;&#x3B5 independent of the type of cylinder used, with the exception of compression values in oblique load of 30 degrees where the three types of cylinder surpassed the pathological overhead state with over 4,000 &#x3BC;&#x3B5.
39

Estabilidade dimensional da resina acrílica para coroas provisórias em função de diferentes tipos de processamento / Dimensional stability of acrylic resin for provisional crowns for different types of processing

García-López, David Alejandro 27 April 2009 (has links)
A importância das restaurações provisórias no tratamento reabilitador oral é inquestionável. Os materiais utilizados para a elaboração deste tipo de restauração, também são de grande importância, tanto em função da técnica de manuseio como na qualidade e características dos mesmos, devido ao fato de que deles depende a longevidade, adaptação e qualidade das restaurações provisórias. O tipo de manipulação e a técnica utilizada influem nas propriedades físicas das resinas acrílicas, o que poderia causar falhas de adaptação. Por essas razões, o presente estudo teve por objetivo avaliar a estabilidade dimensional de uma resina acrílica (Dencor®), utilizada na confecção de coroas provisórias. Foram avaliados cinco tipos de processamento: I polimerização térmica utilizando líquido de polimerização rápida em mufla; II autopolimerização sob pressão em matriz de aço inox; III autopolimerização utilizando pincel; IV autopolimerização após mistura (pó + líquido) em pote dappen e inserção em matriz de aço inox na fase arenosa; V autopolimerização após mistura em pote dappen com inserção na matriz de aço inox na fase plástica. Para cada tipo de processamento foram confeccionados 10 corpos-de-prova. Foi avaliada sua estabilidade dimensional por meio de matrizes de aço inox confeccionadas seguindo a especificação da ADA No 19. Os corpos de prova foram armazenados em água destilada a uma temperatura de 37oC por 6 meses. Durante este tempo eles foram examinados com o microscópio óptico Mitutoyo com aumento de 20 vezes. Os resultados foram submetidos à análise de variância (Teste de Tukey) em nível de 5% de significância. Dos resultados obtidos, observamos que todos os corpos de prova tiveram as alterações dimensionais nos primeiros 7 dias da pesquisa independente da técnica utilizada. Já nos dias 30, 90, 180 não foi observada nenhuma alteração dimensional estatisticamente significante. / The importance of the provisional restorations in the oral rehabilitation treatment is undebated. The materials used for the fabrication of this type of restoration, are, as well, of great importance, as much as in function of the processing technique as in their quality and characteristics, due the fact that of them depend the longevity, adaptation and quality of the restorations. The mixing and processing technique influence the physical properties of acrylic resins, what could interfere with the adaptation of the provisional crowns. For these reasons, the present study aimed at evaluating the dimensional stability of an acrylic resin (Dencor®), used for fabrication of provisional crowns. Five types of processing techniques were evaluated: I thermal polymerization using fast polymerization liquid and flask; II - autopolimerization under pressure in stainless steel matrix; III - autopolimerization using bead brush technique to build the sample; IV - autopolimerization after mixture (powder + liquid) in dappen dish and insertion in stainless steel matrix at the sand phase; V - autopolimerization after mixture in dappen dish with insertion in the stainless steel matrix at the plastic phase. For each type of processing technique, 10 samples were made. Dimensional stability was evaluated by means of steel matrices made following the ADA specification no 19. The samples were stored in distilled water at a temperature of 37oC for 6 months. During this time they were examined with the optic microscope Mitutoyo with 20x magnification. The results were subjected to the analysis of variance (Test of Tukey) at the significance level of 5%. From the results obtained, it could be observed that all samples had dimensional alterations in the first 7 days independent of the technique used. In days 30, 90, 180 there were no statisticaly significant dimensional alteration.
40

"Estudo comparativo da resistência às forças de compressão de uma coroa metalocerâmica fraturada e reparada com resina composta híbrida fotopolimerizável com um dente natural permanente e com uma coroa metalocerâmica íntegra" / Comparative study of the resistance to compression forces of a fractured metal ceramic crown and repaired with composite resin with a non-fractured metal ceramic crowns and a permanent natural tooth

Chaves Filho, Antonio Ruy 28 November 2001 (has links)
As porcelanas odontológicas têm sido dos materiais restauradores estéticos aqueles que mais têm evoluído nos últimos anos. Tradicionalmente, elas são friáveis e incapazes de suportar deformações estruturais quando submetidas a stress. Quando usadas na construção de próteses parciais fixas, uma subestrutura metálica é necessária para impedir que se fraturem sob esforços oclusais. Forças de compressão aplicadas em uma porcelana suportada por metal, de tal forma que não seja possível a sua flexão, poderão ser suportadas em elevadas magnitudes. Entretanto, falhas podem acontecer manifestando-se normalmente por fraturas que exigem a intervenção do clínico no sentido de corrigi-las. Diversos são os métodos propostos para o reparo destas fraturas e as pesquisas desenvolvidas no sentido de se avaliar a união dos materiais restauradores às porcelanas. Neste trabalho, foi feita uma análise das possíveis causas de fratura das cerâmicas, os métodos de reparo indicados, materiais empregados para tal e a eficiência dos sistemas indicados frente às variáveis que envolvem o procedimento restaurador da porcelana. A proposta foi avaliar a resistência máxima às forças de compressão de reparos de fraturas de porcelana realizados com uma resina composta híbrida fotopolimerizável, empregando cargas estáticas comparando-a com a resistência de coroas metalocerâmicas íntegras e dentes naturais permanentes, usados como grupo controle. Os resultados mostraram que frente às forças de compressão aplicadas, a coroa metalocerâmica íntegra e o dente natural não apresentaram diferença estatisticamente significante. A coroa metalocerâmica reparada apresentou menor resistência que a coroa / The odontologic porcelains have been out of the esthetic restorative materials those, which have developed the most in the last years. Traditionally, they are brittle and unable to bear structural deformations when submitted to stress. When used in the building of partial fixed prothesis, one metallic framework is needed to avoid them to fracture under occlusal efforts. Forces of compression enforced on a metal supported porcelain in a way, which is not possible to bend, they could be beared in high magnitudes. However, failures can happen normally revealing themselves through fractures, which demand the intervention of the clinician in order to evaluate the association of the restorative materials to porcelains. In this study na analysis has been made of the possible causes of fractures of the ceramics, the indicated repairing methods, the materials used for it and, the efficiency of the variables, which involves the restorative procedure of the porcelain. The aim was evaluate the utmost resistance to the forces of compression in repairs of fractures of porcelain made with a light-cured hybrid composite resin, using static loads and comparing it with the resistance of the nonfractured metal ceramic crowns and permanent natural human teeth, used as control group The results have shown that in the presence of the compression forces loaded to non-fractured metaloceramic crown and the natural tooth have not exhibited statistically meaningful difference. The repaired metaloceramic crown has exhibited less resistance than the non-fractured metaloceramic one. However, there has not been statistically meaningful difference to the permanent natural tooth

Page generated in 0.0455 seconds