• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 26
  • 26
  • 10
  • 9
  • 8
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Modelo da velocidade crítica em testes de caminhada: validade, reprodutibilidade e aplicabilidade em pacientes de Unidades de Saúde

Ribeiro, Paula Aver Bretanha [UNESP] 05 February 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-02-05Bitstream added on 2014-06-13T20:49:24Z : No. of bitstreams: 1 ribeiro_pab_me_rcla.pdf: 730907 bytes, checksum: c4b0c64a8d54c7184bf1b7c74ea8ea7f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Atualmente avaliação da aptidão física constitui importante ferramenta para prevenção e detecção de problemas físicos que podem interferir na autonomia e independência nas atividades da vida diária. Parâmetros de aptidão física estão direta e indiretamente relacionados com indicadores de saúde como atividade física habitual, qualidade de vida e avaliação antropométrica. O modelo de potência crítica nos fornece, de forma simples e não invasiva, dois parâmetros físicos, um aeróbio e outro anaeróbio. Este tem sido classicamente utilizado para descrever desempenho em atletas e não foi validado a testes não exaustivos, o que ampliaria sua aplicabilidade a populações com contra-indicação a testes máximos. Dois objetivos nortearam esse estudo. 1) Examinar se os testes de caminhada com intensidade autoselecionada fornecem estimativas confiáveis dos parâmetros do modelo e consistentes com a predição do modelo. 2) Examinar a relação entre os parâmetros do modelo da velocidade crítica com indicadores de atividade física relacionada à saúde. Um total de 39 indivíduos (32 a 80 anos) realizaram: 1) testes de caminhada de 3, 6 ou 9 minutos, ou até a exaustão em ritmo préfixado, para a determinação da velocidade crítica de caminhada (VCC) e capacidade de caminhada anaeróbia (CCA), 2) teste de caminhada na VCC e superior; 3) avaliação da qualidade de vida relacionada à saúde; 4) testes de aptidão física relacionada à saúde; 5) monitoramento da atividade física habitual (pedometria). Os resultados demonstraram bons ajustes do modelo aos testes de caminhada... / Evaluation of physical fitness is an important tool to detect and prevent physical disabilities, which can impair the autonomy and the daily life activities. Components of physical fitness are related to health indexes much as physical activity, quality of life and anthropometrics measures. The critical power model provide two physical parameters (aerobic and anaerobic) in an easy and non-invasive way. Even it has been used to describe performance in athletes, it still has not validated to non-exhausted tests, which could be usefull to apply to people with contraindication on exhaustive tests. Two main objectives conducted this study: 1) To exam if self-paced walk tests could estimated reliable parameters of critical power and in accordance to prediction of the model; 2) To exam the relationship between the parameters provided by the critical power model with health related physical activity indexes. A total of 39 volunteers performed: 1) walking tests of 3, 6, or 9 minutes, or until exhaustion in a pre-determined pace. These tests aimed to determine the critical walking velocity (CWV) and the anaerobic walking capacity (AWC); 2) walking tests at and above CWV; 3) health related quality of life assessment; 4) health related physical fitness tests, and; 5) monitoring of habitual physical activity (by pedometers). The results showed good agreement of self-selected walking speed tests to the model (r2 = 0,996 + 0,005), and no difference between the strategies of data collection was detected. The test-retest intraclass... (Complete abstract click electronic access below)
22

Efeito do consumo agudo de cafeína na capacidade anaeróbia quantificada pelos principais métodos de estimativa

VAZ, Lucyana Galindo Arcoverde 29 March 2016 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-08-31T14:27:00Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Mestrado LUCYANA GALINDO ARCOVERDE VAZ.pdf: 1541733 bytes, checksum: 075c4e7b9b3f5f39a8de2b68a1df2f24 (MD5) / Made available in DSpace on 2016-08-31T14:27:00Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Mestrado LUCYANA GALINDO ARCOVERDE VAZ.pdf: 1541733 bytes, checksum: 075c4e7b9b3f5f39a8de2b68a1df2f24 (MD5) Previous issue date: 2016-03-29 / CAPEs / A ação ergogênica da cafeína sobre a capacidade anaeróbia (CAN) está relacionada à melhora do desempenho. Entretanto, os estudos que investigaram o efeito da cafeína sobre a capacidade anaeróbia utilizaram apenas o máximo déficit acumulado de oxigênio (MAOD) como método de estimativa. Avaliar o efeito do consumo agudo de cafeína sobre a CAN estimada através dos principais métodos de estimativa, MAOD, potência crítica (ponto de intercepção y da função trabalho/tempo), fase rápida de recuperação do consumo de oxigênio + concentração de lactato (3 compartimentos) e eficiência mecânica grossa (EF), que por apresentarem medidas representativas da CAN, detectam igualmente os possíveis efeitos do consumo agudo de cafeína sobre o metabolismo anaeróbio. Nove participantes realizaram um teste incremental no cicloergômetro para determinação do primeiro limiar ventilatório (LV1) e do consumo máximo de oxigênio (VO2máx). A partir da carga referente ao LV1 foram calculadas a carga de aquecimento (90% do LV1), e as cargas dos testes experimentais. Foram doze testes experimentais, sendo seis com cafeína e seis placebo, em um desenho duplo-cego, contrabalanceado e controlado por placebo. A contribuição anaeróbia foi calculada pelos principais métodos de estimativa. Os achados mostraram que os métodos não detectam a mesma medida de CAN, logo, eles não são equivalentes na estimativa. Em relação ao efeito da cafeína sobre a estimativa sim, não houve diferença entre cafeína e placebo, exceto MAOD, que teve uma medida mais alta na situação cafeína. Além disso, não houve diferença no tempo de exaustão entre cafeína e placebo na carga supramáxima. Os métodos de estimativa não são equivalentes, eles não apresentam a mesma medida da CAN. A cafeína influenciou um dos métodos, MAOD, e isso levou a uma superestimativa da medida, quando corrigido pela estimativa do placebo, não apresentou mais diferença. Além disso, a cafeína não promoveu melhora no desempenho na carga supramáxima. / The caffeine ergogenic action on anaerobic capacity (AC) is related to performance’s improvement. However, some studies used only the maximal accumulated oxygen deficit (MAOD) as estimative method to investigate the effect of caffeine on anaerobic capacity. Evaluate the effect of acute caffeine consumption over the estimated AC through the main estimative methods, MAOD, critical power (interception point y work function/time), fast recovery phase of oxygen consumption + lactate concentration (3 compartments) and gross mechanical efficiency (GME), which by presenting representative measures of AC also detect the possible effects of acute caffeine consumption on the anaerobic metabolism. Nine participants performed an incremental test on a cycle ergometer to determine the first ventilatory threshold (VT1) and the maximal oxygen uptake (VO2max). From VT1 power output were calculated warm up load (90% of VT1), and the loads of the experimental trials. Twelve experimental trails were performed, being six after caffeine and six after placebo in a double-blind, placebo-controlled and counterbalanced design. AC was calculated by main estimative methods. The findings of the present study showed that AC was not detected similarly by the estimative methods, which might assume that they are not equivalent in the estimative. However, MAOD was higher in after caffeine ingestion when compared to placebo. There were no differences between trials in the other estimative methods. In addition, the time to exhaustion was not different between caffeine and placebo in supramaximal exercise. The estimative methods are not equivalent to measure AC. However, caffeine influenced MAOD, which probably overestimate the measurement. However, when corrected by the placebo estimative, no differences between trials was observed. Furthermore, caffeine was not efficient to improve the performance at supramaximal exercise.
23

Comparação do limiar anaeróbio e da carga crítica com relação aos parâmetros cardiorrespiratórios, metabólicos e eletromiográficos no exercício resistido de Leg Press 45° em jovens e idosos / Comparison of anaerobic threshold and critical load in relation to cardiorespiratory, metabolic and EMG parameters, in resistance exercise Leg Press 45º in young and elderly

Vivian Maria Arakelian 31 March 2015 (has links)
A crescente demanda pelo treinamento resistido tem incentivado a procura de metodologias para a prescrição deste tipo de exercício. Por isso, há uma busca incessante para se prescrever corretamente qual parâmetro e/ou intensidade seja a ideal para a execução do exercício resistido. Dessa forma protocolos incrementais podem ser interessantes, uma vez que podem determinar a magnitude das respostas fisiológicas (principalmente lactato e consumo de oxigênio) em diferentes domínios (leve, moderado e alto), pois através deles é possível identificar parâmetros de aptidão aeróbia e anaeróbia, como o limiar de lactato, limiar anaeróbio e carga crítica. No entanto, poucos estudos têm analisado de forma sistematizada diferentes intensidades de exercício resistido com o objetivo de determinar a magnitude das respostas cardiorrespiratórias, metabólicas e eletromiográficas para então propor estratégias reabilitadoras a indivíduos idosos baseada nestas respostas. Dessa forma, o objetivo principal desse estudo foi comparar as intensidades determinadas como limiar anaeróbio e carga crítica, em relação aos parâmetros de frequência cardíaca, ventilação, consumo de oxigênio, lactato, débito cardíaco, volume sistólico, além da análise eletromiográfica, entre jovens e idosos. Participaram deste estudo 35 homens ativos, sendo 20 jovens (média de idade de 23 ± 3 anos) e 15 idosos (média de idade de 70 ± 2,4 anos), aparentemente saudáveis. Todos os voluntários realizaram, de forma aleatória e em dias diferentes a: 1) teste de 1 RM em exercício resistido no Leg Press 45°; 2) teste de exercício físico resistido dinâmico crescente descontínuo; 3) três testes de exercícios resistidos de alta intensidade de carga constante (60%, 75% e 90% de 1 RM) até a fadiga e, após estes testes realizaram:, 4) teste de tolerabilidade no limiar anaeróbio, obtido através do teste crescente e, 5) teste de tolerabilidade da carga crítica obtida, pela regressão linear e relação hiperbólica entre carga e tempo de execução. Com relação ao limiar anaeróbio, obtido no teste incremental, foi possível determinar que este ocorreu em torno de 30% 1 RM e a carga crítica foi aproximadamente 52% 1 RM, para ambos os grupos. Com relação aos parâmetros estudados nas intensidades de exercício executadas, o envelhecimento mostrou ser determinante para uma redução nos valores relativos à capacidade aeróbia bem como na frequência cardíaca. Já com relação especificamente as intensidades do limiar anaeróbio e carga crítica, em ambos os grupos a ventilação, foi maior e consumo de oxigênio foi menor na intensidade da carga crítica. Já para as respostas de lactato, nós observamos menores valores para o grupo idoso, tanto para o limiar como na carga crítica. O débito cardíaco apresentou diferença apenas entre os grupos e não entre as intensidades, sendo que devido ao envelhecimento, houve redução dos valores. Já para a EMG, houve maiores quedas do slope da FM para idosos quando comparado aos jovens em 30%, e além disso, na intensidade de 30% acarretou em menor queda que em 52%. Ao comparar ao longo do tempo a FM e o RMS, o comportamento destes foi semelhantes nas duas intensidades, ou seja, de queda e aumento, respectivamente, o que é indicativo de maior fadigabilidade ao final do exercício. Além disso, a taxa de queda foi maior no grupo idoso, sendo que esse parâmetro é um indicador de maior fadiga muscular para este grupo. Entretanto, o comportamento do RMS ao final das duas intensidades foi menor nos idosos. Dessa forma, nossos resultados podem ter aplicações como uma forma de avaliar o desempenho funcional durante exercícios resistidos em diferentes populações e também pode ter utilidade na prescrição de um programa de treinamento dependo do objetivo a ser alcançado, elucidando a importância prática da aplicação de exercícios de resistência dinâmica. / The increasing demand for resistance training has motivated the search methodologies for prescribing this type of exercise. Therefore, there is a constant search to correctly prescribe which parameter and/or intensity is ideal for the implementation of resistance exercise. Thus incremental protocols may be interesting, since they can determine the magnitude of physiological responses (mainly lactate and oxygen consumption) in different domains (mild, moderate and high), because it is possible through them to identify parameters of aerobic and anaerobic fitness as the lactate threshold, anaerobic threshold and critical load. However, few studies have examined systematically different resistance exercise intensities form in order to determine the magnitude of the cardiorespiratory, metabolic and electromyographic responses and then propose the elderly rehabilitation strategies based on these answers. Thus, the aim of this study was to compare the intensities determined as anaerobic threshold and critical load, with respect to heart rate parameters, ventilation, oxygen consumption, lactate, cardiac output, stroke volume, besides the electromyographic analysis, between young and senior citizens. The study included 35 active men, 20 young (mean age 23 ± 3 years) and 15 older adults (mean age 70 ± 2.4 years), apparently healthy. All volunteers pertormed randomly on different days to: 1) 1 RM test in resistance exercise in Leg Press 45º; 2) dynamic resistance exercise test growing discontinuous; 3) three tests of resistance exercise high intensity constant load (60%, 75% and 90% of 1 RM) to failure and after these tests, performed 4) tolerance test at the anaerobic threshold, obtained by increasing test, 5) tolerability test critical load obtained by linear regression and hyperbolic relationship between load and runtime. Regarding the anaerobic threshold obtained in the incremental test, was determined that this occurred around 30% 1 RM and the critical load was approximately 52% 1 RM for both groups. As for the parameters studied in the exercise intensities performed, aging proved to be decisive for a reduction in the relative values of aerobic capacity and heart rate. In relation specifically the intensities of the anaerobic threshold and critical load in both grups, ventilation was higher and oxygen consumption was lower in the intensity of the critical load. As for the lactate responses, we observed lower values for the elderly group, both the threshold and the critical load. Cardiac output was difference only between groups and not between the intensities, and due to aging, decreased the values. As for EMG, was greater MF of the slope falls to elderly compared to 30% in young, and furthermore, intensity of 30% fall which resulted in less by 52%. Comparing over time RMS and MF, was similar in behavior of the two intensities, ie, increase and decrease, respectively, which is indicative of greater fatigue at the end of exercise. Furthermore, the decrease rate was higher in the elderly group, and this parameter is an indicator of increased muscle fatigue for this group. However, RMS behavior at the end of the two intensities were lower in the elderly. Thus, our results may have applications as a way to evaluate the functional performance during resistance training in different populations and can also be useful in prescribing a training program depend on the objective to be achieved, explaining the practical importance of the application of resistance exercise dynamics.
24

Correlações entre os valores de lactato mínimo e potência anaeróbia com a potência crítica e a capacidade de trabalho anaeróbio obtidas por método invasivo e não invasivos

Afonso, Marcia [UNESP] 17 May 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:52Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-05-17Bitstream added on 2014-06-13T19:49:12Z : No. of bitstreams: 1 afonso_m_me_rcla.pdf: 222236 bytes, checksum: 1a0edd0d0141d788c0b3436c47d1f119 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O limiar anaeróbio (LAN) tem sido muito utilizado como preditor da capacidade aeróbia na avaliação e prescrição do treinamento. Dentre os protocolos de determinação do LAN, o método do lactato mínimo (LM) parece ser um dos mais precisos, determinando de certa forma, individualmente os valores do LAN. Um outro modelo utilizado na avaliação do parâmetro aeróbio é o método não invasivo de determinação de potência crítica (PC), sendo que esse modelo possibilita também a quantificação das reservas anaeróbias intramusculares (CTA). Vários autores propõem determinações de PC por diferentes protocolos, dentre eles, os propostos por JENKINS & QUIGLEY em 1991 (PCJQ) e CHASSAIN em 1986 (PCCH) especialmente, são muito diferentes, no aspecto metodológico e repercutiram bastante no meio científico. O objetivo do presente estudo foi de comparar métodos invasivos e não invasivos de avaliação aeróbia e anaeróbia em atletas ciclistas, identificando a relação existente entre o LM e a PC (determinada por dois métodos diferentes) e, a relação dos parâmetros anaeróbios, através da potência média e da potência pico com a CTA. Foram voluntários desse estudo 9 ciclistas treinados do sexo masculino (24,11 1,62 anos; 67,28 4,37 kg e 175,78 5,89 cm) com experiência na modalidade. Os atletas foram submetidos a três protocolos experimentais: 1) Teste de LM, com teste de Wingate para induzir a acidose e posterior exercício progressivo; 2) Teste de PCJQ com quatro sessões de cargas exaustivas randômicas; 3) Teste de PCCH a partir da variação da freqüência cardíaca e do lactato através de dois esforços de 180 segundos com intervalo de pausa de 90 segundos entre os esforços, com intensidade de 85, 95, 105 e 115% do LM. Foram encontradas diferenças significativas entre as intensidades de LM (219,73 4,43 W), PCJQ nos modelos Pot- 1/tlim... . / The anaerobic threshold (AT) has been used as a good predictor of the aerobic capacity for physical evaluation and training prescription. Among the protocols of AT determination, the lactate minimal test (LMT) seems to be one of the most accurate for obtain individually the AT values. Another model used in the aerobic evaluation is the non-invasive method for determination of the critical power (CP), and this model also makes possible the quantification of the intramuscular anaerobic stores, which represents the anaerobic work capacity (AWC). Several authors proposed determinations of CP on different protocols, as those propored by, Jenkins & Quigley (1991 - CPJQ) and Chassain (1986 - CPCH), that in spite of the very different methodological aspects they are a reference in the scientific way. The purpose of the present study was to compare invasive and non-invasive protocols to evaluate the aerobic and anaerobic fitness (by two different methods) in cyclists. Also, the relationship of the mean and peak power obtained during an Wingate test to AWC identified by different methods was investigate. Nine male trained cyclists volunteered to the study (24.11 l 1.62 years; 67.28 l 4.37 kg and 175.78 l 5.89 cm). The athletes were submitted to three experimental protocols: 1) LMT, with initial lactic acidosis induced thought a Wingate test and a subsequent incremental exercise test; 2) test of PCJQ with four sessions of random exhaustive loads; 3) test of PCCH based on the variation of the heart rate and lactate along two bouts of efforts of 180 seconds with pause interval of 90 seconds between them, with intensity of 85, 95, 105 and 115% of LMT. Our results showed significant differences among the intensities of LMT (219.73 l 4.43 W), PCJQ in the models P-1/tlim (301.47 l 10.46 W) and Wlim - tlim (295.22 l 10.14 W) and, in PCCH for the methods of lactate variation (201.53 l 4.44 W) and... (Complete abstract, click electronic address below).
25

Correlações entre os valores de lactato mínimo e potência anaeróbia com a potência crítica e a capacidade de trabalho anaeróbio obtidas por método invasivo e não invasivos /

Afonso, Marcia. January 2004 (has links)
Orientador: Claudio Alexandre Gobatto / Banca: Eduardo Kokubun / Banca: Herbert Gustavo Simões / Resumo: O limiar anaeróbio (LAN) tem sido muito utilizado como preditor da capacidade aeróbia na avaliação e prescrição do treinamento. Dentre os protocolos de determinação do LAN, o método do lactato mínimo (LM) parece ser um dos mais precisos, determinando de certa forma, individualmente os valores do LAN. Um outro modelo utilizado na avaliação do parâmetro aeróbio é o método não invasivo de determinação de potência crítica (PC), sendo que esse modelo possibilita também a quantificação das reservas anaeróbias intramusculares (CTA). Vários autores propõem determinações de PC por diferentes protocolos, dentre eles, os propostos por JENKINS & QUIGLEY em 1991 (PCJQ) e CHASSAIN em 1986 (PCCH) especialmente, são muito diferentes, no aspecto metodológico e repercutiram bastante no meio científico. O objetivo do presente estudo foi de comparar métodos invasivos e não invasivos de avaliação aeróbia e anaeróbia em atletas ciclistas, identificando a relação existente entre o LM e a PC (determinada por dois métodos diferentes) e, a relação dos parâmetros anaeróbios, através da potência média e da potência pico com a CTA. Foram voluntários desse estudo 9 ciclistas treinados do sexo masculino (24,11 1,62 anos; 67,28 4,37 kg e 175,78 5,89 cm) com experiência na modalidade. Os atletas foram submetidos a três protocolos experimentais: 1) Teste de LM, com teste de Wingate para induzir a acidose e posterior exercício progressivo; 2) Teste de PCJQ com quatro sessões de cargas exaustivas randômicas; 3) Teste de PCCH a partir da variação da freqüência cardíaca e do lactato através de dois esforços de 180 segundos com intervalo de pausa de 90 segundos entre os esforços, com intensidade de 85, 95, 105 e 115% do LM. Foram encontradas diferenças significativas entre as intensidades de LM (219,73 4,43 W), PCJQ nos modelos Pot- 1/tlim... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The anaerobic threshold (AT) has been used as a good predictor of the aerobic capacity for physical evaluation and training prescription. Among the protocols of AT determination, the lactate minimal test (LMT) seems to be one of the most accurate for obtain individually the AT values. Another model used in the aerobic evaluation is the non-invasive method for determination of the critical power (CP), and this model also makes possible the quantification of the intramuscular anaerobic stores, which represents the anaerobic work capacity (AWC). Several authors proposed determinations of CP on different protocols, as those propored by, Jenkins & Quigley (1991 - CPJQ) and Chassain (1986 - CPCH), that in spite of the very different methodological aspects they are a reference in the scientific way. The purpose of the present study was to compare invasive and non-invasive protocols to evaluate the aerobic and anaerobic fitness (by two different methods) in cyclists. Also, the relationship of the mean and peak power obtained during an Wingate test to AWC identified by different methods was investigate. Nine male trained cyclists volunteered to the study (24.11 l 1.62 years; 67.28 l 4.37 kg and 175.78 l 5.89 cm). The athletes were submitted to three experimental protocols: 1) LMT, with initial lactic acidosis induced thought a Wingate test and a subsequent incremental exercise test; 2) test of PCJQ with four sessions of random exhaustive loads; 3) test of PCCH based on the variation of the heart rate and lactate along two bouts of efforts of 180 seconds with pause interval of 90 seconds between them, with intensity of 85, 95, 105 and 115% of LMT. Our results showed significant differences among the intensities of LMT (219.73 l 4.43 W), PCJQ in the models P-1/tlim (301.47 l 10.46 W) and Wlim - tlim (295.22 l 10.14 W) and, in PCCH for the methods of lactate variation (201.53 l 4.44 W) and... (Complete abstract, click electronic address below). / Mestre
26

Acopladores direcionais de fibras Ãpticas com perfis de dispersÃo / Directional optic staple dispersion profile fiber(DPF)

Almir Wirth Lima Junior 05 March 2007 (has links)
nÃo hà / Nosso trabalho apresenta uma anÃlise numÃrica da propagaÃÃo e comutaÃÃo de solitons fundamentais em acopladores de dois nÃcleos de fibras nÃo lineares construÃdos com fibras de perfis de dispersÃo (DPF). NÃs mostramos, que o formato apropriado do perfil DPF à muito eficaz na recuperaÃÃo, quase total, do comportamento da comutaÃÃo do sinal original associado à situaÃÃo sem perdas. O estudo da comutaÃÃo de solitons em acopladores nÃo lineares de fibras DPF proporciona possibilidades de se alcanÃar alta eficiencia no processamento de sinais ultra-rÃpidos em sistemas totalmente Ãticos, especialmente para comutadores e transistors Ãticos. Iniciamos, estudando as equaÃÃes de Maxwell, os Solitons Ãpticos, as EquaÃÃes dos Modos Acoplados, e a EquaÃÃo NÃo Linear de SchrÃdinger - NLSE (mÃtodos analÃtico, e numÃrico). A seguir, detalhamos a PropagaÃÃo e Chaveamento de Sinais Ãpticos âCWâ e âQuasi-CWâ em Acopladores Ãpticos, bem como analisamos de forma teÃrica os acopladores duplos nÃo lineares de Fibras Ãpticas com Perfis de DispersÃo Decrescente (DPF). Os Ãltimos capÃtulos tratam do objetivo real de nossa DissertaÃÃo, ou seja, a AnÃlise Detalhada de Acopladores Ãpticos de Fibras com Perfis de DispersÃo (DPF), Com, e Sem Perdas Ãpticas, incluindo dois tipos de configuraÃÃo(PA1 e PB1). Encerramos a DissertaÃÃo com as ConclusÃes sobre os estudos acima referidos / We present a numerical investigation of the propagation and the switching of fundamental solitons in a two-core nonlinear fiber coupler constructed with Dispersion Profile Fiber (DPF). We have shown that appropriate shaping of the DPF profile is quite effective to recover, almost completely, the original switching behavior associated to the lossless situation. The study of soliton switching in DPF nonlinear fiber couplers provides possibilities for achieving, high efficiency in ultrafast all-optical signal processing, especially for optical switches and optical transistors. We initiate, studying the Maxwell Equations, the Coupled-Mode Equations, and the the Nonlinear SchrÃdinger Equation - NLSE, (analytic, and numerical approaches). After this, we detail the Propagation and Switching of "CW" and "Quasi-CW" Optical Signals in Optical Couplers, as well like we analyze, through theoretical form, the nonlinear double couplers of Dispersion Profiles Fibers (DPF). The last chapters explain the real objective of our Dissertation, or be, Detailed Analysis of the Optical Couplers of Profiles Dispersion Fiber (DPF), With, and Without Optical Losses, including two kinds of configuration (PA1 and PB1). We enclose the Dissertation with the Conclusions about the above referred studies

Page generated in 0.0908 seconds