• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
711

Avaliação da capacidade seladora apical de um adesivo dentinário, acrescido ou não de hidróxido de cálcio, comparada à de um cimento endodôntico à base de hidróxido de cálcio, na obturação de canais radiculares /

Camargo, Carlos Henrique Ribeiro. January 1998 (has links)
Orientador: Jaime Freitas Ribeiro / Banca: Renato de Toledo Leonardo / Banca: Marcia Carneiro Valera / Resumo: O selamento em obturações endodônticas, utilizando adesivo dentinário acrescido ou não de hidróxido de cálcio, foi comparado ao obtido com um cimento endodôntico comercial, à base de hidróxido de cálcio. Sessenta dentes, divididos em grupos de vinte, tiveram seus canais preparados e obturados pela técnica da condensação lateral de guta-percha, utilizando-se como cimento obturador um adesivo dentinário acrescido ou não de hidróxido de cálcio e um cimento endodôntíco, à base de hidróxido de cálcio (grupo controle). As superfícies externas das raízes foram impermeabilizadas, exceto o forame apical. Os espécimes foram conservados em umidade relativa de 100%, a 37°C, até o momento de sua imersão em corante azul de metileno a 2%, sob vácuo por trinta minutos e à pressão atmosférica por mais 168 h, a 37°C. Após esse período, os espécimes foram lavados em água corrente por 24 h e os agentes impermeabilizantes foram removidos. Cada raiz foi seccionada ao meio, no sentido vestíbulo lingual, permitindo visualizar a interface material obturador/canal radicular. As médias de infiltração foram 2,88mm para o grupo do adesivo associado ao hidróxido de cálcio; 1,87mm para o grupo do adesivo e 0,56mm para o grupo controle. A análise estatística mostrou não haver diferença entre os resultados dos dois primeiros grupos. As infiltrações observadas no grupo controle foram as menores e estatisticamente diferentes das dos grupos experimentais / Abstract: The sealing afforded by endodontic obturations using a dentin bonding agent with and without calcium hydroxide was compared to the sealing of a calcium hydroxide - based sealer (Sealer 26). The root canals of sixty extracted human teeth were prepared biomecanichally and filled by the lateral condensation technique with gutta-percha points and the sealer (Sealer 26) as the control group, or a dentin bonding agent with calcium hidroxide or dentin bonding agent without calcium hydroxide. The roots were placed into a 2% metlylene blue dye solution under vacuum for thirty minutes. After this period they were kept for 168h at 37ºC. The roots were sectioned longitudinally and the depth of dye penetration mensured linearly, in a steriomicroscope. The mean values were: 2,88mm for the the dentin bonding agent with calcium hydroxide group; 1,87mm for the dentin bonding agent group and 0.56 mm for the control group. The results showed that the control group leakage significanty less (p 0,05) than the other two groups, which exhibited no statistical difference between both of them / Mestre
712

Resposta pulpar de dentes de ratos após tratamento capeador direto com sistema adesivo monocomponente ou autocondicionante

Favaretto, Lúcia Helena Denardi Roveroni [UNESP] 14 July 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-07-14Bitstream added on 2014-06-13T19:08:51Z : No. of bitstreams: 1 favaretto_lhdr_me_sjc.pdf: 917162 bytes, checksum: e8cc872310ab876c14fe70a8cf5a5d20 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do trabalho foi avaliar a resposta pulpar de dentes de ratos a diferentes sistemas adesivos diretamente aplicados sobre exposições pulpares. Foram realizados preparos oclusais com exposição pulpar nos primeiros e segundos molares superiores. O grupo C (controle, n=34) recebeu como material capeador o cimento de hidróxido de cálcio Dycal, no E1 (n=31) foi aplicado o sistema adesivo Single Bond e no E2 (n=30) o sistema adesivo auto-condicionante One-up Bond F. Os materiais foram aplicados conforme especificações dos fabricantes e todas as cavidades restauradas com resina composta. Os animais foram sacrificados após sete, trinta e 45 dias e as polpas dentárias foram histologicamente avaliadas. Os dados foram analisados estatisticamente utilizando-se o teste exato de Fisher. Observou-se que aos sete dias não houve diferença entre C e E2 com relação à resposta inflamatória e à organização pulpar, predominando quadros de inflamação crônica focal e perdas odontoblásticas localizadas. O E1 demonstrou diferença estatisticamente significativa em relação ao E2, exibindo maior número de casos com necrose. Aos sete dias a contaminação bacteriana da polpa foi menor no grupo tratado com One-up, porém, todas as diferenças mencionadas foram perdidas com o decorrer do tempo, equiparando-se os três grupos aos 45 dias, período em que predominou a necrose pulpar. Houve um aumento no número de barreiras dentinárias formadas e na contaminação bacteriana do tecido pulpar com o aumento do tempo experimental. Concluiu-se que o tratamento capeador direto, conforme o modelo experimental empregado, demonstrou ser histologicamente insatisfatório, independentemente do material empregado. / The aim of this study was to evaluate the pupal response to different adhesives systems directly applied on mechanically exposed pulps in rats. The oclusal surfaces of first and second molars were prepared and the pulps exposed. In C (control group-n=34) pulps were capped with a calcium hydroxide paste (Dycal); E1 (n=31) received the Single Bond adhesive system and E2 (n=30) was treated with the self-etching One-up Bond F adhesive system. The materials were applied according to the manufacture's instructions and cavities were restored with Z100 composite resin. Animals were sacrificed after seven, thirty and 45 days and histological features of the dental pulp were evaluated. The Fisher test was used as statistical analysis. At seven days C and E2 presented similar inflammatory response and pulpal organization, showing focal chronic inflammation and localized odontoblast cell lost. E1 and E2 demonstrated statistically significant difference regarding to pulpal organization and inflammatory response; the former exhibiting much more necrosis. At seven days, bacterial contamination of the dental pulp was less evident with One-up Bond F. All these differences were lost with time and after 45 days, pulpal necrosis and bacterial contamination prevailed in the three groups. The formation of the dentin barrier was greater with time in the three groups. The results presented suggest negative effects of direct pulp capping on molar teeth of rats using Dycal, One-up Bond F and Single Bond, under the experimental conditions described.
713

Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis instalados sem estabilidade primária em tíbia de coelhos: estudo biomecânico, histométrico e imunoistoquímico

Souza, Francisley Ávila [UNESP] 20 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-20Bitstream added on 2014-06-13T20:50:49Z : No. of bitstreams: 1 souza_fa_me_araca.pdf: 9106608 bytes, checksum: bdf2875ef072ff8cbc586f8e3743f207 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Aplicação do copolímero PLA/PGA adicionado ao fosfato de cálcio ao redor de implantes osseointegráveis sem estabilidade primária instalados em tíbia de coelhos. Estudo biomecânico, histométrico e imunoistoquímico. Proposição: O objetivo do presente trabalho foi avaliar comportamento mecânico e biológico do tecido ósseo ao redor de implantes associados ao copolímero ácido polilático/poliglicólico adicionado ao fosfato de cálcio. Materiais e Métodos: Para tal foram usados vinte e cinco coelhos Albinus. Após procedimento cirúrgico os animais foram divididos em 4 períodos, sendo o último período, 60 dias, composto por 10 animais. Os animais tiveram perfurações realizadas com sobrefresagem na porção medial das tíbias direita e esquerda. Na tíbia direita o leito cirúrgico foi preenchido com coágulo sanguíneo e na tíbia esquerda com o copolímero. Em ambos leitos cirúrgicos a instalação dos implantes osseointegráveis ocorreu imediatamente após a fresagem. Nos períodos de 5, 15, 40 e 60 dias os animais foram anestesiados e sofreram eutanásia por meio de perfusão de Formaldeído 4% no ventrículo esquerdo. Nos períodos de 40 e 60 dias realizou-se o torque reverso para remoção dos implantes. As peças dos 5 animais restantes do período de 60 dias foram levadas ao micrótomo Exakt para realização de cortes histológicos com os implantes. Nas demais peças, realizou-se análise imunoistoquímica mediante a utilização dos anticorpos primários contra as proteínas OPG, RANK e RANKL. Resultados: As médias de torque para o grupo controle foram de 10,2 e 5,6 N/cm nos períodos de 40 e 60 dias respectivamente, enquanto para o grupo tratado foram de 7,6 e 7,0 N/cm nos mesmos períodos. Houve um balanço na expressão das proteínas com leve predomínio de RANKL. / Application of PLA/PGA copolymer added to calcium phosphate around osseointegrated implants with no primary stability in rabbits's tibia. A biomecanical, histometric and immunohistochemistry study. Purpose: The aim of the present study was to evaluate the mechanical and biological behaviour of bone tissue formed around the implants associated to copolymer polilactic/poliglicolic acids added to calcium phosphate. Materials and Methods: In the present study, twenty five Albinus rabbits, divided in 4 periods, and the last period, referred to 60 days, was composed by 10 animals. The animals had perfurations performed with osteotomy in the medial portion of right and left tibias. In the right tibia, the surgical bed was filled with blood clot and in the left tibia, the copolymer was used. In the same way in both surgical beds, the osseointegrated implants installation occurred immediately after the osteotomy. In the periods of 5, 15, 40 and 60 days, the animals were anesthetized and were sacrificed by perfusion with 4% formaldehyde, in the left ventricule. In the periods of 40 and 60 days, the reverse torque was performed in order to remove the implants. The pieces of the 5 remaining animals of the 60 days period were processed in the Exakt microtome in order to realize undecalcified histological sections with the implants. In the other pieces, the immunohistochemical analysis was performed in order to detect the presence of the OPG, RANK and RANKL proteins in the bone tissue. Results: The mean of torque for the control group were 10.2 and 5.6 N/cm in the periods of 40 and 60 days respectly, while in the treated group were 7.6 and 7.0 N/cm in the same periods. There was a balance in the expression of the proteins with moderate predominance of RANKL protein. There were no statistically differences between the groups in relation to the linear extension of contact between bone and implant.
714

Influência de soluções irrigadoras na resistência adesiva de pinos de fibra de vidro utilizando cimento resinoso: avaliação através do teste de push-out

Figueiredo, Mariana Diehl [UNESP] 01 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-01Bitstream added on 2014-06-13T20:12:41Z : No. of bitstreams: 1 figueiredo_md_me_sjc.pdf: 1643333 bytes, checksum: 28c65af70a60c705d107f1d4b9fc61c6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Atualmente, os pinos de fibra de vidro têm surgido como uma alternativa para restaurar dentes tratados endodonticamente. Entretanto, a perda da retenção do pino é uma das principais causas de falhas. Portanto, o objetivo deste estudo foi avaliar a resistência de união e o tipo de falha adesiva, em diferentes regiões da raiz, de pinos de fibra de vidro transparente cimentados no canal radicular com cimento de cura dual, variando-se a solução irrigadora utilizada durante o preparo dos canais, através do teste de push-out. Para o estudo, foram utilizados 30 dentes humanos, todos igualmente preparados. No momento da cimentação dos pinos, as soluções irrigadoras foram: solução de soro fisiológico, hipoclorito de sódio 2,5% e solução de clorexidina 2%; e o cimento resinoso utilizado foi de cura dual. Após a cimentação, os espécimes foram seccionados, obtendo-se 2 fatias de aproximadamente 2 mm cada, suas faces cervicais foram marcadas, e então, submetidas ao teste de push-out. Foram realizados os testes ANOVA e Tukey, com nível de significância de 5 %, para a análise do ensaio mecânico e realizada análise qualitativa do tipo de falha ocorrida. Pôde-se observar que o grupo irrigado com hipoclorito de sódio 2,5% apresentou menor valor da média de resistência adesiva (3,870 ± 3,799 MPa), comparado com o grupo da clorexidina 2% (4,215 ± 2,098 MPa) e com o grupo do soro (4,510 ± 1,186 MPa). Já em relação aos terços, a região média foi a que apresentou maior valor da média de resistência adesiva (4,803 ± 3,14 MPa) quando comparado com a região cervical (3,593 ± 1,717 MPa), porém não houve diferença estatística significante, nem entre as regiões e nem entre as soluções irrigadoras. A maioria das falhas ocorridas foram do tipo adesiva 70%, enquanto que 23,33% foram fraturas coesivas, e 6,66% foram do tipo mistas. Assim, é possível concluir que os... / Currently, the fiberglass posts have emerged as an alternative to restore endodontically treated teeth. However, the loss of retention of the pin is a major cause of failure. Therefore, the aim of this study was to evaluate and compare the bond strength of transparent fiberglass posts, using a dual cure cement, varying the irrigating solution used during the preparation of the root canals through the push-out test and then a qualitative analysis of types of adhesion failures was made by reading into a stereomicroscope. For the study, 30 human teeth were used, all equally prepared. At the time of cementation of the posts, the irrigating solutions were: normal saline solution, sodium hypochlorite 2.5%, and 2% chlorhexidine solution, and the resin cement used was dual-curing. After cementation, specimens were sectioned, yielding two slices of about 2 mm each, their cervical faces were marked, and then subjected to push-out test, the data obtained were analyzed by descriptive and inferential statistics. The tests performed were ANOVA and Tukey, with a significance level of 5% for the analysis of mechanical test, and the type of failure occurred was qualitatively evaluated. It could be observed that the group irrigated with sodium hypochlorite 2.5% showed the lowest mean bond strength (3.870 ± 3.799 MPa), compared with 2% chlorhexidine group (4.215 ± 2.098 MPa) and the normal saline solution group (4.510 ± 1.186 MPa). In relation to the thirds, the middle region showed the highest value of bond strength average (4.803 ± 3.14 MPa) compared with the cervical (3.593 ± 1.717 MPa), but differences were not statistically significant, nor between regions nor between irrigating solutions. Most failures were adhesive type 70%, while 23.33% were cohesive fractures, and 6.66% were mixed type. Thus, we conclude that the irrigation protocols evaluated in this study did not exert effects on the bond ... (Complete abstract click electronic access below)
715

Efeito do retratamento endodôntico sobre a resistência de união de cimentos resinosos à dentina intrarradicular

Pereira, Kamila de Figueiredo [UNESP] 16 March 2015 (has links) (PDF)
Made available in DSpace on 2016-12-09T13:52:17Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-16. Added 1 bitstream(s) on 2016-12-09T13:55:21Z : No. of bitstreams: 1 000871280_20180316.pdf: 158424 bytes, checksum: 15003d635d8471431815b61906ca2f76 (MD5) Bitstreams deleted on 2018-03-16T11:41:47Z: 000871280_20180316.pdf,. Added 1 bitstream(s) on 2018-03-16T11:42:34Z : No. of bitstreams: 1 000871280.pdf: 1274238 bytes, checksum: cb1e4a4c32105f78fb83eada295887c4 (MD5) / O objetivo deste estudo foi verificar o efeito do retratamento endodôntico sobre a resistência de união e a penetrabilidade de diferentes sistemas de cimentação de pinos de fibra de vidro à dentina intrarradicular por meio de ensaio mecânico push out, microscopia confocal a laser e microscopia eletrônica de varredura. Foram utilizadas 60 raízes unirradiculares ovaladas de dentes humanos (n=15): ETA -Tratamento endodôntico e cimentação com RelyX ARC; ETU - Tratamento endodôntico e cimentação com U200; ERA - Retratamento endodôntico e cimentação com RelyX ARC; ERU - Retratamento endodôntico e cimentação com U200. Os grupos com tratamento endodôntico convencional foram obturados com AH plus (ETA e ETU) e os grupos que sofreram retratamento endodôntico foram obturados primeiramente com Endofill e após com AH Plus. Os pinos de fibra de vidro receberam como tratamento prévio à cimentação a limpeza com álcool 70%, aplicação de silano e para os grupos ETA e ERA aplicação de adesivo. Para análise em microscópio confocal a laser, foi adicionado ao primer do sistema adesivo e ao cimento autoadesivo o corante fluorescente rodamina B isotiocianato RITC 0,01%. Cada terço radicular foi submetido ao teste de push-out com velocidade de 0,5 mm/min e para verificar a área de adesão e para determinação da penetração e adaptação do cimento na dentina radicular foi feita analise sob microscopia confocal a laser. Na sequência cada um dos espécimes foi analisado em microscopia eletrônica de varredura, as falhas foram classificadas com (AD) adesiva; (MI) mista e (CO) coesiva. Para análise estatística dos resultados foram selecionados os testes ANOVA a dois critérios fixos e Tukey (α<0,05). Como resultado o grupo ETA apresentou maiores valores de resistência de união à dentina intrarradicular que os outros grupos (p<0,05), em todos os terços radiculares ((Resumo completo, clicar acesso eletrônico abaixo). / The aim of this study was to evaluate the effect of endodontic retreatment on the bond strength and the penetrability of different cementing systems of fiberglass posts to root dentin through the push out bond strength, confocal laser microscopy and scanning electron microscopy. Sixty human teeth with single canals and ovalshaped were used (n=15): ETA - Endodontic treatment and cementation with RelyX ARC; ETU - Endodontic treatment and cementation U200; ERA - Endodontic retreatment and cementation RelyX ARC; ERU - Endodontic retreatment and cementation with U200. The groups with conventional endodontic treatment were filled with AH plus (ETA and ETU) and the groups that suffered endodontic retreatment were filled, primarily, with Endofill and, after, with AH Plus.  The fiber glass posts received as a previous treatment, an alcohol 70% cleaning and application of silane. The groups ETA and ERA received adhesive application. For analysis in confocal laser microscope, were added to the primer adhesive system and the self-adhesive cement, the fluorescent dye rhodamine B isothiocyanate RITC 0.01%. Each root third passed for the push-out test, with a speed of 0.5 mm / min and to verify the penetration and adaptation of the cement in the root dentin analysis were made under confocal laser scanning microscopy. Subsequently each of the specimens were analyzed in scanning electron microscopy, the failures were classified (AD) adhesive; (MI) mixed and (CO) cohesive. For statistical analysis of the results, were selected two criteria: the tests two-way ANOVA and the Tukey test (α <0.05). As a result for push out bond strength ETA showed higher bond strength to radicular dentin than the other groups (p < 0.05) in all radicular thirds. Endodontic retreatment interfered negatively on the penetrability and on the push out bond strength of RelyX ARC and U200 cements to dentin, regardless of the analyzed radicular third.
716

Efeito do retratamento endodôntico sobre a resistência de união de cimentos resinosos à dentina intrarradicular /

Pereira, Kamila de Figueiredo. January 2015 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Milton Carlos Kuga / Banca: Marco Antonio Hungaro Duarte / Resumo: O objetivo deste estudo foi verificar o efeito do retratamento endodôntico sobre a resistência de união e a penetrabilidade de diferentes sistemas de cimentação de pinos de fibra de vidro à dentina intrarradicular por meio de ensaio mecânico "push out", microscopia confocal a laser e microscopia eletrônica de varredura. Foram utilizadas 60 raízes unirradiculares ovaladas de dentes humanos (n=15): ETA -Tratamento endodôntico e cimentação com RelyX ARC; ETU - Tratamento endodôntico e cimentação com U200; ERA - Retratamento endodôntico e cimentação com RelyX ARC; ERU - Retratamento endodôntico e cimentação com U200. Os grupos com tratamento endodôntico convencional foram obturados com AH plus (ETA e ETU) e os grupos que sofreram retratamento endodôntico foram obturados primeiramente com Endofill e após com AH Plus. Os pinos de fibra de vidro receberam como tratamento prévio à cimentação a limpeza com álcool 70%, aplicação de silano e para os grupos ETA e ERA aplicação de adesivo. Para análise em microscópio confocal a laser, foi adicionado ao primer do sistema adesivo e ao cimento autoadesivo o corante fluorescente rodamina B isotiocianato RITC 0,01%. Cada terço radicular foi submetido ao teste de "push-out" com velocidade de 0,5 mm/min e para verificar a área de adesão e para determinação da penetração e adaptação do cimento na dentina radicular foi feita analise sob microscopia confocal a laser. Na sequência cada um dos espécimes foi analisado em microscopia eletrônica de varredura, as falhas foram classificadas com (AD) adesiva; (MI) mista e (CO) coesiva. Para análise estatística dos resultados foram selecionados os testes ANOVA a dois critérios fixos e Tukey (α<0,05). Como resultado o grupo ETA apresentou maiores valores de resistência de união à dentina intrarradicular que os outros grupos (p<0,05), em todos os terços radiculares ((Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to evaluate the effect of endodontic retreatment on the bond strength and the penetrability of different cementing systems of fiberglass posts to root dentin through the push out bond strength, confocal laser microscopy and scanning electron microscopy. Sixty human teeth with single canals and ovalshaped were used (n=15): ETA - Endodontic treatment and cementation with RelyX ARC; ETU - Endodontic treatment and cementation U200; ERA - Endodontic retreatment and cementation RelyX ARC; ERU - Endodontic retreatment and cementation with U200. The groups with conventional endodontic treatment were filled with AH plus (ETA and ETU) and the groups that suffered endodontic retreatment were filled, primarily, with Endofill and, after, with AH Plus.  The fiber glass posts received as a previous treatment, an alcohol 70% cleaning and application of silane. The groups ETA and ERA received adhesive application. For analysis in confocal laser microscope, were added to the primer adhesive system and the self-adhesive cement, the fluorescent dye rhodamine B isothiocyanate RITC 0.01%. Each root third passed for the "push-out" test, with a speed of 0.5 mm / min and to verify the penetration and adaptation of the cement in the root dentin analysis were made under confocal laser scanning microscopy. Subsequently each of the specimens were analyzed in scanning electron microscopy, the failures were classified (AD) adhesive; (MI) mixed and (CO) cohesive. For statistical analysis of the results, were selected two criteria: the tests two-way ANOVA and the Tukey test (α <0.05). As a result for push out bond strength ETA showed higher bond strength to radicular dentin than the other groups (p < 0.05) in all radicular thirds. Endodontic retreatment interfered negatively on the penetrability and on the push out bond strength of RelyX ARC and U200 cements to dentin, regardless of the analyzed radicular third. / Mestre
717

Avaliação da resistência à remoção por tração de coroas metálicas fixadas com cimentos resinosos e da dureza desses materiais em função do método de ativação /

Fonseca, Renata Garcia. January 2001 (has links)
Orientador: Carlos Alberto dos Santos Cruz / Banca: Gelson Luis Adabo / Banca: Luís Geraldo Vaz / Banca: Rosehelene Marotta Araújo / Banca: Adriana Cristina Zavanelli / Resumo: Foram avaliados grau de polimerização de cimentos resinosos em função de diferentes intensidades de luz, por meio de ensaio de dureza, e resistência à remoção por tração de coroas cimentadas em troquéis com determinados cimentos. A primeira etapa foi realizada submetendo-se ou não os cimentos resinosos Panavia F, Scothbond Resin Cement, Enforce e Cement-It à fotoativação, tendo as leituras sido realizadas nos tempos imediato, 1 hora, 2 horas, 24 horas e 7 dias após espatulação dos materiais. No segundo ensaio, foram confeccionados troquéis e coroas, ambos em liga de NiCr, os quais, após jateamento e aplicação do agente catalisador do sistema adesivo Scotchbond Multi Uso Plus (3M) em suas superfícies, foram cimentados aos pares com os materiais descritos anteriormente, além do cimento de fosfato de zinco. A análise dos resultados revelou que os cimentos resinosos alcançaram maior dureza nos grupos fotoativados em todos os tempos analisados, com exceção apenas do Scotchbond Resin Cement e Enforce que, aos 7 dias, mostraram igualdade estatística entre os tratamentos. Todos os materiais apresentaram progressão de polimerização em função do tempo na ausência de luz, com diferentes velocidades. Os cimentos Panavia F e Fosfato de Zinco apresentaram, respectivamente, a maior e a menor força de remoção por tração, tendo o Scotchbond Resin Cement, Enforce e Cement-It ficado em posição intermediária, diferenciando-se significativamente dos demais materiais, porém não entre si. / Abstract: The purpose of this study was to evaluate plymerization degree of resin cements subjected to various light exposures, by hardness test, and bond strength of crowns luted to dies using five luting agents. Panavia F, Scothbond Resin Cement, Enforce and Cement-It were exposed or not to light and measurements were taken at baseline, 1 hour, 1 hours and 7 days after mixing. For the second evaluation, dies and crowns were obtained with NiCr alloys and after sandblasting and treatment with catalyzer agent of Scotchbond Multi Uso Plus adhesive system (3M) at both surfaces, cementation was done with the luting agents described before, besides zinc phosphate cement. Statistical analysis revealed greater hardness for photopolymerized groups in all times, excepting Scotchbond Resin Cement and Enforce that, at 7 days, showed no statistical difference between treatments. All cements had polymerization progression with time at light absence, with different speeds. Panavia F and zinc phosphate showed, respectively, the greatest and smallest bond strength, while Scotchbond Resin Cement, Enforce and Cement-It were in a intermediate position, differing significantly of the other cements, but not between theirserlves. / Doutor
718

Dentina humana e bovina: estudo comparativo das propriedades físicas e características da hibridização de sistemas adesivos convencionais ou grander modificados: análise em mev /

Gonçalves, Sérgio Eduardo de Paiva. January 2005 (has links)
Resumo: A adesão longitudinal continua a representar um dos maiores desafios da Odontologia moderna. Uma nova proposta para o estabelecimento do equilíbrio da adesão aos tecidos dentários surge, baseada na observação dos resultados obtidos com a tecnologia Grander para revitalização da água. Objetiva-se com o estudo verificar a influência dessa tecnologia nas propriedades físicas de dois sistemas adesivos (convencional e autocondicionante) à partir da medição da tensão superficial e do ângulo de contato; e avaliar a formação e a qualidade da camada híbrida em dentina humana e bovina. A tensão superficial de quatro diferentes líquidos (água, Single Bond- 3M, Primer do Clearfil SE Bond -Kuraray, e Bond do Clearfil SE-Kuraray), foi medida antes e após a modificação pelo procedimento Grander em aparelho goniômetro (Ramé-hart). O ângulo de contato com três substratos distintos (placa de titânio, dentina humana e dentina bovina), foi medido para os quatro líquidos também antes e após a modificação pelo procedimento Grander, também em goniômetro. A formação e qualidade da camada híbrida, foi avaliada em MEV, a partir da confecção de corpos de prova dos substratos humano e bovino, devidamente embutidos, preparados em lixas de variada granulação até a exposição de dentina, submetidos ao procedimento adesivo (SB ou CSEB) normal ou grander modificado, recebendo ao final dupla camada de resina composta Z250-3M, fotopolimerizada por 40s. Após armazenamento em estufa bacteriológica por 24h, os procedimentos para análise ao MEV foram realizados (fixação, desidratação, secagem e metalização). A estatística de Análise de Variância ANOVA e Teste de Tukey 5% revelou que: houve redução estatisticamente significante da tensão superficial para todos os líquidos Grander modificados; houve redução estatisticamente... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A long-lasting adhesion is still one of the biggest challenges of the modern Dentistry. A new approach to reaching the equilibrium of the adhesion to the dental tissues emerges based on the observation of the results obtained with the Grander Technology for revitalizing water. The aim of this study was to verify the influence of this technology on the physical properties of two adhesive systems (conventional and self-etching) through the measurement of the surface tension and of the contact angle and through the evaluation of the formed hybrid layer in human and bovine dentin. The surface tension of four different liquids (water, Single Bond - 3M, Clearfil SE primer - Kuraray and Clearfil SE bond - Kuraray) was measured before and after submitting these liquids to the Grander modifying unit, with the aid of a goniometer (Ramé-hart). The measurement of the contact angle of the liquids followed the same procedure using three distinct surfaces: titanium plate, human dentin and bovine dentin. The hybrid layer formed for both: non-modified and Grander modified adhesive systems, was evaluated in SEM. For this purpose human and bovine dentin samples were prepared. The teeth were fixed in acrylic resin and the dentin surfaces exposed and finished with various grit polishing paper discs. These dentin surfaces were then treated with the adhesive procedures (normal and Grander modified), before the placement of a double composite resin layer (Z250- 3M). After storage at 37oC for 24h, the SEM analysis were conducted. The data were submitted to ANOVA and Turkeys test 5%. The results showed statistically significant reduction for the surface tension of all liquids modified by the Grander technology, as well as for the contact angle in the human dentin. Statistically significant were also the results showing a thicker hybrid layer formation with the two adhesive systems when modified by the Grander... (Complete abstract click electronic access below)
719

Estudo comparativo da eficacia de dois adesivos dentinarios e um cimento de ionomero de vidro empregados na adesão do amalgama a dentina /

Huhtala, Maria Filomena Rocha Lima. January 1995 (has links)
Orientador: Jose Benedicto de Mello / Banca: Celso Luiz de Angelis Porto / Banca: Maria Amélia Maximo de Araujo / Resumo: Este estudo teve como objetivo realizar a avaliação ln vitro, da resistência da adesão do amálgama, Dispersalloy, à dentina, quando dois adesivos dentinários, Amalgambond Plus (AP) e Scotchbond Multi Purpose (SMP) e um cimento de ionômero de vidro, Vitrebond (V), foram empregados no tratamento desta superfície dentinária. Trinta dentes terceiros molares humanos recém-extraídos, foram seccionados em metades vestibular e lingual, que foram incluídas em blocos de resina acrílica, de modo a terem suas superfícies dentinárias superficiais expostas com lixas de granulação crescente: 100, 180, 400 e 600; sob constante refrigeração de água. Sobre estas superfícies dentinárias foram fixados tubos de polietileno com 3 mm de diâmetro e 5 mm de altura, estabilizados com uma matriz de teflon e alumínio, permitindo assim a condensação do amálgama, imediatamente após o tratamento com um dos sistemas adesivos: AP, SMP,V. Após a confecção dos cilindros de amálgama, as amostras foram estocadas à 37º C por 24 horas, antes de serem submetidas aos testes mecânicos de cisalhamento em máquina Instron a uma velocidade de 0,5 mm/minuto. Os resultados da força requerida para o cisalhamento dos cilindros de amálgama foram expressos em MPa e as superfícies, dentinárias e de amálgama, observadas em estereomicroscopia, após a fratura. Os dados foram analisados através do modelo estatístico de análise de variância. A força média de adesão, quando como agente intermediário entre amálgama/ dentina, foi utilizado o AP, foi de 2,21 ± l ,5 MPa , quando o SMP de 0,33 ± 0,8 MPa e o V de 2,63 ± 1,66 MPa. O AP e o V foram considerados estatisticamente semelhantes (p>0,05) e diferentes do SMP (p<0,05). As fraturas foram predominantemente adesivas na interface amálgama/resina para o SMP (73,34%) e consideradas mistas, do amálgama/sistema adesivo, para o AP (80%) e para o V (93,36%) / Abstract: The purpose of this in vitro study was to determine the shear bond strengths of amalgam to dentin treated with the Amalgambond Plus (AP) and Scotchbond Multi Purpose (SMP) dentin adhesive systems and with the glass-ionomer cement, Vitrebond (V).The buccal and lingual superficial dentin surfaces of thirty extracted human third molars were exposed by wet grinding on 600-grit silicon carbide and the bonding areas demarcated with plastic band matrices (3mm/5umm),fixed in position by the means of a rigid aluminium/teflon mold. The demarcated dentin surfaces were treated with AP, SMP and V as directed by the manufacturers and freshly mixed Dispersalloy amalgam condensed into the plastic matrices. The specimens were then stored in 37°C for 24 hours. The matrices were removed; the shear bond tests performed in an Instron Universal Testing Machine at a cross-head speed of 0.5mm/sec.; and the results expressed in MPa. Some failures were examined in stereomicroscopy. The data were analysed by one-way analysis of variance, Mean failure loads and S.D, were: AP, 2,21 ± 1,5; SMP, 0,33±0,8 e V, 2,63± l,6. Tire shear bond strengths of AP vs V were not significantly different (p>0,05) and SMP was significantly different (p<0,05), Stereomicroscopic analysis demonstrated adhesive failures for SMP (7334%) at the resin/amalgam interface and mixed failures for AP (80%) and for V (933%) within both systems / Mestre
720

Resposta pulpar de dentes de ratos após tratamento capeador direto com sistema adesivo monocomponente ou autocondicionante /

Favaretto, Lúcia Helena Denardi Roveroni. January 2004 (has links)
Orientador: Silvio Issao Myaki / Banca: Silvio Issao Myaki / Banca: Rosangela Almeida Ribeiro / Banca: Sigmar de Mello Rode / Resumo: O objetivo do trabalho foi avaliar a resposta pulpar de dentes de ratos a diferentes sistemas adesivos diretamente aplicados sobre exposições pulpares. Foram realizados preparos oclusais com exposição pulpar nos primeiros e segundos molares superiores. O grupo C (controle, n=34) recebeu como material capeador o cimento de hidróxido de cálcio Dycal, no E1 (n=31) foi aplicado o sistema adesivo Single Bond e no E2 (n=30) o sistema adesivo auto-condicionante One-up Bond F. Os materiais foram aplicados conforme especificações dos fabricantes e todas as cavidades restauradas com resina composta. Os animais foram sacrificados após sete, trinta e 45 dias e as polpas dentárias foram histologicamente avaliadas. Os dados foram analisados estatisticamente utilizando-se o teste exato de Fisher. Observou-se que aos sete dias não houve diferença entre C e E2 com relação à resposta inflamatória e à organização pulpar, predominando quadros de inflamação crônica focal e perdas odontoblásticas localizadas. O E1 demonstrou diferença estatisticamente significativa em relação ao E2, exibindo maior número de casos com necrose. Aos sete dias a contaminação bacteriana da polpa foi menor no grupo tratado com One-up, porém, todas as diferenças mencionadas foram perdidas com o decorrer do tempo, equiparando-se os três grupos aos 45 dias, período em que predominou a necrose pulpar. Houve um aumento no número de barreiras dentinárias formadas e na contaminação bacteriana do tecido pulpar com o aumento do tempo experimental. Concluiu-se que o tratamento capeador direto, conforme o modelo experimental empregado, demonstrou ser histologicamente insatisfatório, independentemente do material empregado. / Abstract: The aim of this study was to evaluate the pupal response to different adhesives systems directly applied on mechanically exposed pulps in rats. The oclusal surfaces of first and second molars were prepared and the pulps exposed. In C (control group-n=34) pulps were capped with a calcium hydroxide paste (Dycal); E1 (n=31) received the Single Bond adhesive system and E2 (n=30) was treated with the self-etching One-up Bond F adhesive system. The materials were applied according to the manufacture's instructions and cavities were restored with Z100 composite resin. Animals were sacrificed after seven, thirty and 45 days and histological features of the dental pulp were evaluated. The Fisher test was used as statistical analysis. At seven days C and E2 presented similar inflammatory response and pulpal organization, showing focal chronic inflammation and localized odontoblast cell lost. E1 and E2 demonstrated statistically significant difference regarding to pulpal organization and inflammatory response; the former exhibiting much more necrosis. At seven days, bacterial contamination of the dental pulp was less evident with One-up Bond F. All these differences were lost with time and after 45 days, pulpal necrosis and bacterial contamination prevailed in the three groups. The formation of the dentin barrier was greater with time in the three groups. The results presented suggest negative effects of direct pulp capping on molar teeth of rats using Dycal, One-up Bond F and Single Bond, under the experimental conditions described. / Mestre

Page generated in 0.073 seconds