• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2304
  • 155
  • 150
  • 150
  • 148
  • 109
  • 35
  • 35
  • 24
  • 17
  • 17
  • 12
  • 7
  • 5
  • 2
  • Tagged with
  • 2362
  • 1247
  • 1039
  • 886
  • 534
  • 523
  • 493
  • 433
  • 425
  • 347
  • 234
  • 192
  • 180
  • 166
  • 163
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
731

Influencia do tratamento de superficie em uma liga de paladio-prata na resistencia de união de agentes cimentantes

Prates, Luiz Henrique Maykot 27 November 2000 (has links)
Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T20:39:56Z (GMT). No. of bitstreams: 1 Prates_LuizHenriqueMaykot_D.pdf: 5542298 bytes, checksum: 2937ad4a5face46e3b58742cc05f9700 (MD5) Previous issue date: 2000 / Resumo: O propósito do estudo foi avaliar a influência de quatro tratamentos de superfície, efetuados em uma liga de paládio-prata, na resistência da união ao cisalhamento de três agentes cimentantes. Inicialmente, foram confeccionadas fundições em forma de disco (5 mm de diâmetro), com liga de paládio-prata, sendo os espécimes agrupados em pares, após limpeza manual e em ultra-som com água. Em seguida, os pares foram separados em quatro grupos de 30 cada, para realização de um dos seguintes tratamentos nas faces circulares opostas às correspondentes aos condutos de alimentação: 1 - bruto de fundição (controle); 2 aplicação de jato de óxido de alumínio malha 320; 3 - aplicação de jato de óxido de alumínio malha 60; e 4 - aplicação de jato de micro esferas de vidro malha 270. Após nova limpeza em ultra-som com água destilada, durante 5 minutos, os exemplares de cada grupo foram separados em três sub-grupos de 10 cada, sendo feita a fixação, através das faces tratadas, com um dos seguintes agentes cimentantes: A - cimento de fosfato de zinco; B - cimento de ionômero de vidro modificado por resina; e C - cimento resinoso. Dez espécimes de cada tratamento de superfície foram submetidos à análise da rugosidade média, sendo também feito Lo preparo de dois exemplares para observação com microscopia eletrônica de varredura. Após 24 horas de armazenagem em água destilada a 37°C, os pares fixados foram avaliados com ensaios de cisalhamento em máquina Instron (1 mm/min), até a ruptura das amostras. Os resultados foram submetidos à análise de variância e ao teste de Tukey (p < 0,05) e as médias obtidas (MPa) foram: Grupo 1 A: 1,77 (0,51); Grupo 1 B: 3,18 (1,42); Grupo 1 C: 1,63 (0,55); Grupo 2 A: 5,22 (0,88); Grupo 2 B: 11,90 (1,94); Grupo 2 C: 16,29 (3,94); Grupo 3 A: 4,03 (0,78); Grupo 3 B: 11,41 (2,69); Grupo 3 C: 14,15 (2,71); Grupo 4 A: 1,59 (0,44); Grupo 4 B: 2,24 (0,71); Grupo 4 C: 1,74 (0,51). As superfícies metálicas submetidas ao jato de óxido de alumínio (malhas 320 ou 60) proporcionaram maior resistência de união que a condição de bruto de fundição e que as superfícies submetidas ao jato de micro esferas de vidro malha 270. Nas superfícies tratadas com jato de óxido de alumínio, o cimento resinoso e o cimento de ionômero de vidro modificado por resina proporcionaram resistências de união estatisticamente superiores à do cimento de fosfato de zinco. Não houve relação entre a resistência de união dos agentes cimentantes e a rugosidade média das ligas metálicas / Abstract: The purpose of this study was to evaluate the influence of four metal surface treatments on the shear bond strength of three luting agents. Cast samples in a disk shape (5 mm in diameter) were made with palladium-silver alloy and grouped in pairs afier ultrasonic cleaning. The pairs were assigned into four groups of 30 each and submitted to the following treatments on the circular surfaces opposite to that of the sprue former: 1 - as cast (control); 2 - aluminum oxide blasting (320 mash); 3 - aluminum oxide blasting (60 mash); and 4 - glass beads blasting (270 mash). Afier new ultrasonic cleaning in distilled water, during 5 minutes, the samples of each group were assigned into three subgroups of 10 each, being made the cementing, by the treated surfaces, with the following luting agents: A - zinc phosphate cement; B - resin-modified glass ionomer cement; and C ¿ resin cement. Before luting, 10 specimens of each treatment had the surfaces measured for roughness and two samples were prepared to observation in scanning electronic microscope. Afier storing in distilled water at 37°C, during 24 hours, the cemented pairs were submitted to shear bond strength tests in an Instron machine (1 mm/min), until the failure. The results were analyzed by ANOVA and Tukey's test (p < 0,05) and the means (MPa) were: Group 1 A: 1.77 (0.51); Group 1 B: 3.18 (1.42); Group 1 C: 1.63 (0.55); Group 2 A: 5.22 (0.88); Group 2 B: 11.90 (1.94); Group 2 C: 16.29 (3.94); Group 3 A: 4.03 (0.78); Group 3 B: 11.41 (2.69); Group 3 C: 14.15 (2.71); _Group 4 A: 1.59 (0.44); Group 4 B: 2.24 (0.71); Group 4 C: 1.74 (0.51). The metallic surfaces submitted to the aluminum oxide blast treatment (320 or 60 mash) showed bond strengths significantly higher than those of surfaces as cast or submitted to glass beads blast (270 mash). On surfaces treated with aluminum oxide blast, the resin cement and the resin-modified glass ionomer cement showed bond strengths statistical/y superior to those of the zinc phosphate cement. There was not a relationship between the bond strengths of cementing agents and the roughness of metal/ic surfaces / Doutorado / Doutor em Materiais Dentários
732

Analise visual do potencial cariostatico in vitro de materiais restauradores associados a aplicação de dentifricios

Rodrigues, Jose Augusto 29 March 2001 (has links)
Orientadores : Giselle Maria Marchi Baron, Monica Campos Serra / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:52:07Z (GMT). No. of bitstreams: 1 Rodrigues_JoseAugusto_M.pdf: 13528347 bytes, checksum: 5bfcd4540b1b6b7df57a99e3966846d8 (MD5) Previous issue date: 2001 / Resumo: A prevenção ou paralisação de lesões cariosas adjacentes às restaurações pode ser aIcançada pela correta remoção de placa e utilização de fluoretos tópicos. Para pacientes de alto risco, é ainda recomendado o uso de materiais restauradores cariostáticos, embora ainda não se conheça o verdadeiro efeito da sua associação aos fluoretos. O objetivo deste trabalho foi avaliar, in vitro, o efeito cariostático de 6 materiais restauradores contendo ou não flúor associados à aplicação de dentifrícios em esmalte dental humano. Cavidades classe V foram preparadas no esmalte de 240 fragmentos dentais, aleatoriamente divididos em 12 grupos. Após serem restauradas as cavidades, os fragmentos foram submetidos a ciclos térmicos e de desmineralização e remineralização, simulando um alto desafio cariogênico. Sobre os fragmentos restaurados, ainda, foram aplicados dentifrícios contendo ou não flúor 5 minutos por dia. As diferenças no desenvolvimento de lesões experimentais de cárie adjacente às restaurações foram avaliadas por 5 examinadores calibrados, através de inspeção visual, atribuindo-se escores de 0 a 3. Os resultados foram avaliados pelo teste de Kruskal-Wallis seguido pelo teste de comparações múltiplas (?=0,05). Quando associados ao dentifrício fluoretado, os materiais restauradores não diferiram entre si em relação ao potencial cariostático. Ketac-Fil foi o único material que não diferiu significativamente quando associado com o dentifrício com ou sem flúor. Sob as condições experimentais do estudo, a associação dos materiais restauradores ao dentifrício fluoretado resultou em uma maior ação cariostática, exceto para o cimento de ionômero de vidro, que não diferiu com a aplicação dos dentifrícios / Abstract: The prevention or arrestment of caries lesions around restorations may be done through plaque removal and use of topical fluorides. Restorative materiaIs that release fluoride are still recommended for patients with high caries risk, although the real effect of their association with topical fluorides is not known. The aim of this study was to evaluate, in vitro, the cariostatic effect of six restorative materiaIs that contain fluoride associated with fluoride and non-fluoride dentifrices on human dental enamel. Standardized class V cavities were prepared on 240 enamel fTagments,randomly assigned in 12 groups. After cavity restoration, the fragments were submitted to 1000 thermal cycles, and to demineralization/remineralization cycles, simulating a high cariogenic challenge. During pH cycles, slurries of fluoride and non-fluoride dentifuces were applied for tive minutes after demineralization solution. Artificial caries-like lesions formations were scored independently and blindly by tive calibrated examiners, using a 0 to 3 ordinal scale through visual inspection. The data were evaluated by Kruskal-Wallis test, followed by paired comparisons test (?=0,05). There were no significant differences among restorative materiaIs when associated with fluoride dentifuces. Ketac-Fil was the unique that did not differ when associated with fluoride or non-fluoride dentifrices. Under experimental conditions, the association of restorative materiaIs with a fluoride dentifrice provided better cariostatic effect, except to the conventional glass ionomer cement, whose effect did not change with the dentifrice application / Mestrado / Dentística / Mestre em Clínica Odontológica
733

Avaliação da adaptação marginal, resistencia de união e nanoinfiltração de restaurações indiretas utilizando a tecnica de selamento dentinario e cimento resinoso / Evaluation of marginal adaptation, bond strength and nanoleakage of indirect restorations using resin coating technique and resin cement

Correa Medina, Alberth David 12 August 2018 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T20:03:41Z (GMT). No. of bitstreams: 1 CorreaMedina_AlberthDavid_D.pdf: 2483854 bytes, checksum: 56098c8765561f8bf74fb59fa865130c (MD5) Previous issue date: 2009 / Resumo: As restaurações estéticas indiretas têm sido a opção de escolha no caso de cavidades extensas. No entanto, este tipo de restauração demanda um desenho de preparo muito mais invasivo, podendo levar a sensibilidade pós-operatória, assim como também, certa incompatibilidade entre o cimento resinoso e o adesivo. Na tentativa de solucionar estas limitações tem sido sugerida uma técnica chamada de "Resin Coating Technique" ou Técnica de Selamento Dentinário (TSD), que consiste em proteger a superfície exposta após o preparo com um sistema adesivo e sobre este é aplicado ou nao um "liner" (monômero hidrófobo ou resina composta de baixa viscosidade). A utilização desta técnica vem oferecendo bons resultados, embora, pouco se sabe referente à combinação apropriada entre adesivo e "liner" e a interação desta técnica com os diferentes tipos de cimento resinoso. Portanto, este estudo teve como objetivos avaliar a influencia de diferentes combinações da TSD, na adaptação marginal, resistência de união, nanoinfiltração de restaurações indiretas, e após de ter identificado a combinação mais apropriada para a TSD, foi avaliada a interação desta com os cimentos resinosos através dos testes de adaptação marginal e resistência de união. Para estes estudos foram avaliados as combinações de sistemas adesivos que utilizam o condicionamento acido prévio de 2 e 3 passos e adesivos autocondicionantes de 1 e 2 passos seguido da aplicação ou não aplicaçao de uma camada de "liner" (monômero hidrófobo/resina composta de baixa viscosidade). Nas combinações avaliadas os grupos que obtiveram menores resultados tanto para adaptação marginal e resistência de união foram as combinações que não utilizaram liner. O grupo adesivo autocondicionante de 2 passos/resina composta de baixa viscosidade apresentou maior resistência de união e menor grau de nanoinfiltração. No entanto, todas as combinações avaliadas de TSD não conseguiram evitar a desadaptação marginal e nanoinfiltração das restaurações. Referente ao comportamento desta combinação com diferentes tipos de cimento, foi avaliada a adaptação marginal e resistência de união de diferentes cimentos resinosos (autocondicionante, autoadesivo e de ativação química) obtendo como resultados que o grupo que obteve melhores valores de resistência de união foi o grupo que utilizou cimento autocondicionante, embora não houve diferença entre os cimentos no que se refere à adaptação marginal. Por tanto, pelos achados destes estudos conclui-se que para obter melhor adaptação marginal utilizando a TSD é necessária a aplicação de um liner. A combinação de sistema autocondicionante 2 passos/resina de baixa viscosidade obteve maiores valores de resistência de união e menor padrão de nanoinfiltração. O cimento resinoso autocondicionante mostra-se ser o mais compatível com a TSD. / Abstract: Indirect esthetic restorations have been considered an excellent restorative alternative for extensive cavities. However, this type of restoration demands a more invasive preparation, which may cause post-operative sensibility and incompatibility between resin cement and adhesive system. In attempt to minimize these limitations the Resin Coating Technique (RCT) has been proposed. This technique consists in protecting the exposed dentin after the cavity preparation with an adhesive, followed by the application or not application of a liner (hydrophobic monomer or low viscosity resin). The effectiveness of this technique was reported in several studies, however, little is known about the appropriate combination between adhesive and liner and the behavior of this RCT with different resin cements. Therefore, the aims of this study were: evaluate the influence of the combination of different materials used in the RCT on the marginal adaptation, bond strength and nanoleakage of indirect restorations and after identify the most appropriate combination for the RCT, was evaluated the behavior of this RCT with different resin cements using the marginal adaptation and bond strength tests. For these studies were evaluated etch and rise adhesive system (2 and 3 steps) and self-etch adhesives (2 and 1step) followed of the application of liner layer (hydrophobic monomer or low viscosity resin). In all evaluated combinations, the groups that showed low results in marginal adaptation and bond strength were the combinations that not used a liner. The group self etch 2 steps/flow composite resin, showed high bond strength and low nanoleakage. However, in all the restorations showed marginal disadaptation and nanoleakage, independent of the material combinations used for the resin coating. In the study about the interaction of the RCT with the type of resin cement (Self-etching, Self-Adhesive and Chemical Cure) evaluating marginal adaptation and bond strength, was obtained the highest bond strength for the Self-etch group, however, there is no difference between groups for marginal adaptation. So, within the limits of this study, it can be concluded that the use of a liner is necessary for a better marginal adaptation using the RCT. The combination of self etch 2steps/flow composite resin showed high bond strength and low nanoleakage. The self etch resin cement revealed high bond strength showing more compatibility with the RCT. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
734

Analise fotoelastica da distribuição de tensões em implantes osseointegraveis com diferentes desenhos / Analyze fotoelastic the distribution of tensions in osseointegrables implants of different designs

Perez, Miguel Angel Jaimes 13 August 2018 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T22:50:05Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_D.pdf: 10680088 bytes, checksum: c91b56bc63db2e1197b0228d1fc609d5 (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi analisar qualitativa e quantitativamente a distribuição das tensões geradas em modelos fotoelásticos após a aplicação de cargas verticais de 150N, em implantes osseointegráveis de diferentes desenhos. Foram selecionados 3 implantes: I.) Serson Implant 3,75 x 13 mm, Hexágono Externo; II.) Colosso RC 4,0 x 13 mm, Hexágono Interno; III.) Kopp 4,0 x 13 mm, Cone Morse. Para a análise da distribuição de tensões foram confeccionadas 3 hemimandibulas em resina fotoelástica a partir da duplicação de três réplicas de hemimandibulas humanas de poliuretano. Cada implante foi posicionado e fixado no interior da hemimandibula fotoelástica na região do segundo pré-molar ausente. Através do polariscópio circular pertencente ao laboratório de Materiais Dentários da Faculdade de Odontologia de Piracicaba FOP-UNICAMP, foi possível visualizar as franjas isocromáticas nos modelos. Na análise qualitativa foi observado o início da primeira franja e a distribuição das tensões quando aplicado 150N de carga. A análise quantitativa foi obtida através da formula da lei ótica das tensões, conhecendo a respectiva ordem de franja no ponto de interesse, a constante ótica do material e a espessura do modelo. Este cálculo permitiu conhecer a tensão cisalhante de cada implante. O implante cilíndrico Serson, H.E apresentou distribuição das tensões na região cervical, apical e média do implante com maior tensão cisalhante na região cervical, seguido pela região media e apical. O implante Colosso RC com H.I apresentou distribuição das tensões na região apical, cervical e média do implante com um padrão uniforme de tensões nas três regiões. O implante Kopp, com desenho cônico e C.M apresentou distribuição das tensões na região cervical, apical, e média do implante com maior concentração de tensão cisalhante na região apical, seguido pela região cervical e media conjuntamente. Baseado nos resultados e na metodologia empregada neste estudo conclui-se que os três desenhos de implantes apresentaram padrões diferentes de distribuição de tensões, observando-se menor concentração de tensões nos implantes cônicos com conexões internas H.I e C.M. O implante cilíndrico com H.E apresentou maior concentração de tensão / Abstract: This study qualitatively and quantitatively analyze the distribution of tensions generated in fotoelastic models after the application of vertical loads of 150N in osseointegrables implants of different designs. We selected 3 implants: I.) Serson Implant 3.75 x 13 mm, External Hexagon II.) Colosso RC 4.0 x 13 mm, Internal Hexagon, III.) Kopp 4.0 x 13 mm, Morse Cone. For the analysis of the distribution of tensions, 3 hemimandibles using fotoelastic resin from the duplication of three replics of human hemimandibles of polyurethane were made. Each implant was placed and fixed inside the fotoelastic hemimandibles in the region where the second pre-molar was absent. Through a circular polariscope belonging to the Dental Materials, School of Dentistry of Piracicaba (FOP - UNICAMP) laboratory was able to see the isochromatics fringes in the models. In the qualitative analysis was observed the beginning of the first fringe and the distribution of the tensions when was applied a load of 150N. A quantitative analysis was obtained through the optical formula law of the tensions, knowing the order of fringe at the point of interest, an optical constant of the material and the thickness of the model. This calculation allowed to know the cisalhante shear of each implant. The cylindrical implant Serson HE showed distribution of the tensions in the cervical, middle and apical region of the implant with great tension shear in the cervical, followed by middle and apical region. The implant Colosso RC with HI showed distribution of the tensions in the apical, cervical and middle region of the implant with a uniform pattern of the tensions in these three regions. The implant Kopp with conic design and CM showed distribution of the tensions in the cervical, apical, and middle region of the implant with great concentration of the tension shear in the apical region, followed by cervical and middle together. Based on the results and methodology used in this study, we concluded that the three designs of implants showed different patterns of distribution of the tensions, with less concentration of the tensions in the conical implants with internal connections HI and CM. The cylindrical implant with HE showed higher concentration of the tension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
735

Avaliação da adaptação marginal e resistencia compressiva de restaurações esteticas tipo onlay e da dureza knoop de um cimento resinoso dual / Evaluation of marginal fit and compression strenght of onlay esthetic restorations and Knoop hardness of a dual-cured resin cements

Paula, Andreia Bolzan de 13 February 2007 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T05:25:28Z (GMT). No. of bitstreams: 1 Paula_AndreiaBolzande_M.pdf: 1101741 bytes, checksum: 8ff48065954bc02fa4336247fc151298 (MD5) Previous issue date: 2007 / Resumo: O avanço da Odontologia Estética tem sido impulsionado pela introdução de novos compósitos resinosos e técnicas restauradoras. Para amenizar as falhas associadas à contração de polimerização, a técnica indireta tem se tornado uma alternativa na restauração de dentes com preparos extensos. Entretanto, a polimerização incompleta do agente cimentante pode ocasionar redução do desempenho físico e mecânico da restauração. Dessa forma, os objetivos desta dissertação foram: (1) avaliar o efeito da técnica restauradora e do tratamento termo/mecânico na adaptação marginal e resistência compressiva de restaurações estéticas tipo onlay fixadas com cimento resinoso e (2) a influência de diferentes espessuras de compósito resinoso e distâncias da ponta ativa do aparelho fotoativador na dureza Knoop do agente cimentante Rely-X ARC utilizado nas restaurações indiretas. No estudo 1, preparos tipo onlay foram realizados em 50 terceiros molares hígidos e restaurados com compósito resinoso Z-250. Os dentes foram separados em grupos de acordo com a técnica restauradora (direta/indireta) e a ciclagem termo/mecânica. Para a análise da adaptação marginal foi aplicada uma solução corante nas margens da restauração e as áreas coradas foram consideradas como presença de fendas marginais, as quais foram mensuradas através do software Image Tool 3.0. Todos os espécimes foram submetidos ao teste de resistência à compressão. No estudo 2 foi utilizado um incisivo bovino incluído em resina de poliestireno. A face vestibular foi planificada e sobre ela aplicada uma película de PVC e uma matriz de borracha, dentro da qual foi inserido o cimento resinoso Rely-X ARC e uma nova película de PVC. Discos de compósito resinoso, de espessuras diferentes, foram confeccionados e inseridos individualmente sobre este conjunto e fotoativados por 40 segundos, variando a distância da ponta ativa do fotoativador. Após armazenagem por 24h a 37oC, as amostras foram seccionadas longitudinalmente ao meio e polidas para mensuração da dureza Knoop em 3 profundidades do cimento. No estudo 1, não houve diferença estatisticamente significativa entre as técnicas restauradoras quanto à presença de fendas, entretanto, o tratamento termo/mecânico influenciou significativamente o aumento de fendas marginais. Na resistência à compressão não houve diferença estatística significativa entre as técnicas restauradoras empregadas e o tratamento termo/mecânico também não influenciou significativamente à resistência à compressão (RC). No estudo 2, a distância da ponta ativa do fotoativador assim como diferentes espessuras do disco de resina composta, resultou em valores de dureza Knoop estatisticamente distintos, nas profundidades. O aumento da espessura do disco de compósito resinoso ocasionou diminuição dos valores de dureza do cimento. Foi observado diminuição dos valores de dureza apenas quando foi utilizada a distância da ponta do fotoativador de 1mm. As regiões de base e centro apresentaram, respectivamente, os menores e maiores valores de dureza Knoop. Com base nos resultados obtidos pode-se concluir que as técnicas direta e indireta para restauração tipo onlay apresentaram similar resistência à fratura por compressão. A adaptação marginal foi influenciada pelo tratamento termo/mecânico; com o aumento da espessura do compósito restaurador e da distância do fotoativador, houve redução dos valores de dureza do cimento resinoso / Abstract: Esthetic Dentistry has advanced increasingly with the introduction of new resin composites and restorative techniques. To reduce failures associated with polymerization contraction, indirect technique has become an alternative to restoration of teeth with extensive preparations. However, the incomplete polymerization of luting agent can cause a decrease in the physical/mechanical performance of restorations. The objectives of this dissertation were to evaluate: (1) the effect of restorative technique and thermo/mechanical cycling on themarginal adaptation and compressive strength of onlay esthetic restorations bonded with luting resin agent and (2) the influence of different thickness of resin composite discs and the distances of tip of curing unit on Knoop hardness of luting agent Rely-X ARC used in indirect restorations. In the study 1, onlay cavity preparations were performed in 50 sound third molars that were restored with resin composites Z-250. The teeth were divided in groups according to the restorative technique (direct/indirect) and the thermal/mechanical cycling. To analyze the marginal adaptation, a dye solution was applied on the restoration margins and the dyed areas were considered as marginal gaps and measured by means of Image Tool 3.0 software. All specimens were submitted to mechanical test of compressive strength. In the study 2, a bovine incisor was embedded in a polystyrene resin. The buccal surface was ground flatted and over it was applied a PVC pellicle and a rubber mold. The luting cement Rely-X ARC was inserted into the mold and a new PVC pellicle was applied. Resin composite discs, with different thickness, were performed and placed individually over this set (tooth/luting cement) and polymerized for 40 seconds, modifying the distance of tip of light curing. After storing at 37o C for 24 hours, specimens were longitudinally sectioned in two equal parts and polished to measure the Knoop hardness in three depth of cement. In the study 1, there was no statistically difference between the restorative techniques in relation to marginal gaps; however, thermal/mechanical cycling exerted significant influence on the increase of marginal gaps. About the compressive strength, any statistically difference was observed among the restorative techniques, independent of the thermal/mechanical cycling. In the study 2, the distance of tip of curing unit and distinct thickness of composite resin discs resulted in statistically different Knoop values when deepness was analyzed. The increase of resin disc thickness causes reduction on the hardness values of cement. Reductions on hardness values were observed only with 1mm tip curing unit distance. The base showed the lowest means while the center showed the highest. Based in the results obtained it could be concluded that direct and indirect techniques to onlay restoration had similar compressive strength. Marginal adaptation was influenced by thermal/mechanical cycling; increasing of resin composite thickness and distance of active tip of light curing unit, there was a reduction of hardness values of resin cement / Mestrado / Mestre em Materiais Dentários
736

Estudo comparativo da adaptação entre copings metalicos e de alumina, no sistema In-Ceram, antes e apos cimentação / Comparative study of the adaptation between metallic copings and alumina, in system In-Ceram, before and after cementation

Silva, Ligia Luzia Buarque e 28 February 2007 (has links)
Orientador: Alexandre Brait Landulpho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T12:46:11Z (GMT). No. of bitstreams: 1 Silva_LigiaLuziaBuarquee_M.pdf: 635465 bytes, checksum: 8a219ce71e1bbac8283981b9072232bf (MD5) Previous issue date: 2007 / Resumo: Este estudo analisou comparativamente a adaptação marginal antes e após a cimentação de copings metálicos e de alumina, no sistema In-Ceram, em preparos sobre dentes bovinos, utilizando dois tipos de cimento. Sessenta incisivos bovinos foram fixados em resina acrí­lica ativada quimicamente e as porções coronárias foram preparadas para coroa total, utilizando pontas diamantadas tronco cÃ'nica no 4103 com paredes axiais com expulsividade de 8o e término cervical em ombro. Trinta coroas foram confeccionadas para cada tipo de coping. Após, os copings foram adaptados sobre os preparos com carga estática de 9 Kgf por 1 minuto e a discrepância marginal foi medida com microscópio de mensuração (STM). Em seguida, os copings foram removidos e 15 amostras de cada tipo de coping foram cimentados sobre os dentes com cimento de fosfato de zinco (SS White, Petrópolis, RJ. Brasil) e 15 com cimento resinoso (Rely X ARC 3M/ESPE Divisão Dental â?¿ Brasil), aplicou-se uma carga estática de 9 Kgf por 7 minutos e novamente a discrepância marginal foi medida. Os resultados foram submetidos à  Análise de Variância e ao Teste de Tukey (5%) e indicaram que os dois tipos de copings apresentaram desajuste cervical após a cimentação estatisticamente superior ao desajuste cervical antes da cimentação, para os dois cimentos. O sistema In-Ceram apresentou valores de desajuste cervical estatisticamente superior quando cimentados com cimento resinoso. Nenhuma diferença estatá­stica foi observada entre os dois tipos de copings quando cimentados com cimento de fosfato de zinco / Abstract: The purpose of this study was to evaluate the marginal fit before and after cementation of metal and aluminium oxide In-Ceram copings, on bovine teeth preparation using two kinds of cement. Sixty bovine incisors were embedded in resin and the coronal portions of the teeth were prepared to receive complete crowns usin a 4103 diamond bur under refrigeration with 8o of tapering and right shoulder. Thirty crowns were fabricated for each coping. The crowns were then seated on the teeth with 9 Kgf static loads for 1 minute and the marginal discrepancy was mensured using a microscopic (STM). Afterwards, the copings were removed and fifteen samples of each coping were luted on the teeth with zinc phosphate (SS White/Esp, Petrópolis, RJ. Brasil) and resin cement (Rely X ARC 3M/ESPE Divisão Dental â?¿ Brasil), applied 9 Kgf static loads for 7 minutes and the marginal discrepancy was mensured again. Data were submitted to analysis of variance and TukeyÂ's test (5%); results showed that the two copings had cervical fits after cementation statistically higher than those before cementation, concerning both cements. The In-Ceram system showed statistically higher values for the cervical fits when resin cement was used. No statistically significant difference was found between the copings concerning cements with zinc phosphate / Mestrado / Protese Dental / Mestre em Clínica Odontológica
737

Efeito do fluor de um sistema adesivo na resistencia de união e no desafio acido em dentina / Effect of fluoride containing adhesive system on microtensile bond strength and acid challenge on dentin

Shinohara, Mirela Sanae 28 February 2007 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T05:02:58Z (GMT). No. of bitstreams: 1 Shinohara_MirelaSanae_D.pdf: 3018873 bytes, checksum: 16d55d49d5fce271495b768e34d15abc (MD5) Previous issue date: 2007 / Resumo: Apesar do avanço na odontologia adesiva, não é possível conseguir uma união perfeita da resina composta ao substrato dental. Diversos são os adesivos dentinários atualmente presentes, mas nenhum é capaz de impedir a infiltração marginal, degradação e formação de cárie secundária na interface dente-resina ao longo do tempo. Dessa forma, como alternativa, o flúor foi incorporado a um adesivo com o objetivo de promover uma ação antibacteriana e impedir a formação de cárie secundária, conseqüentemente aumentar a longevidade da restauração. Portanto, este estudo teve como objetivos: (1) avaliar a influência do flúor presente no adesivo na resistência de união em dentina e analisar a estrutura da interface dente-adesivo após desafio ácido por meio de microscopia eletrônica de varredura (MEV); (2) avaliar a influência do flúor no adesivo na resistência de união em dentina após 24 horas e 3 meses de estocagem de água, observar a formação de uma zona ácido-resistente na interface dentina-resina após 24 horas e 3 meses de estocagem em água por meio de microscopia de luz polarizada (MLP), e comparar o grau de conversão do adesivo que contém flúor com dois adesivos sem flúor após 24 horas, 1 semana e 1 mês. Tanto para o teste de resistência à microtração, como para análise das interfaces: terceiros molares humanos hígidos recém-extraídos foram usados para realização das restaurações, de acordo com os grupos analisados em cada estudo específico. Para a análise do grau de conversão, pastilhas dos adesivos foram preparados em temperatura controlada e atmosfera de nitrogênio para análise de espectrofotômetria de infravermelho pela técnica transformada de Fourier em modo de transmissão (FTIR). Os resultados mostraram que o flúor presente no adesivo apresenta um efeito positivo na resistência de união, embora apresente menor grau de conversão comparado aos adesivos sem flúor. As imagens de MEV e MLP mostraram que o adesivo com flúor forma uma zona de inibição adjacente à camada híbrida após desafio ácido / Abstract: Despite of the advance in adhesive dentistry, it is not possible to achieve an ideal bonding between composite resin and dental substrate. Currently, a variety of adhesive systems have been used. However, any adhesive system is capable to hamper the marginal leakage, degradation, and secondary caries formation at dentin-resin interfaces in long-term. For that reason, as an alternative, fluoride was incorporated in adhesive in order to promote an antibacterial action and to impede the secondary caries formation, onsequently increasing the longevity of restoration. Thus, the objectives of this study were: (1) to evaluate the influence of a fluoride-containing adhesive on the microtensile bond strength (µTBS) in dentin, and to analyze the ultra-structure of the dentin-adhesive interface after acid challenge; (2) to evaluate the influence of fluoride-containing adhesive on µTBS after 24 hours and 3 months waterstorage; to observe an acid-resistant zone at resin-dentin interface using polarized light microscopy (PLM) after 24 hours and 3 months water storage, and to compare the degree of conversion of fluoride-containing adhesive with non-fluoride containing adhesives after 24 hours, 1 week, and 1 month. For both, to the µTBS test and to analyze the ultra-structure of interfaces: free-caries human third molars were used for restorations, in accordance with of the analyzed groups in each specific study. In order to measure the degree of conversion, chips of adhesives were prepared at a constant temperature and in a nitrogen atmosphere for the analysis at Fourier Transform-Raman spectroscopy (FTIR). The results showed that the present fluoride-containing adhesive has a positive effect in bonding strength, although the lower degree of conversion compared with non-fluoride adhesives. The photomicrographs of SEM and PLM demonstrated that fluoride-containing adhesive allow the formation of an inhibition zone adjacent to the hybrid layer after acid challenge / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
738

Influencia do desenho dos implantes endosseos na distribuição de tensões apos aplicação de cargas verticais e obliquas : analise estrutural e fotoelastica / Influence of dental implant design on tensions distribution after vertical and oblique loading : a structural and phtoelactic study

Perez, Miguel Angel Jaimes 18 July 2008 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T23:04:29Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_M.pdf: 6909101 bytes, checksum: 41413f644c388e8bd46795ab371670ee (MD5) Previous issue date: 2008 / Resumo: Este estudo teve como objetivo analisar a influência do desenho dos implantes endósseos na distribuição de tensões geradas nos modelos fotoelásticos após aplicação de cargas verticais e oblíquas a 7,5N, em quatro marcas comerciais de implantes endósseos. Foram selecionados doze implantes, divididos em quatro grupos: I.) Máster Conect Cônico1 4,3 x 13 mm; II.)Titamax Ti Medular2 3,75 x 13 mm; III.) Colosso3 RC 4,0 x 13mm; IV.) Bicon Uncoated Implant4 3,5 x 11mm, cada grupo contendo 3 implantes da mesma marca comercial. Através da Microscopia Eletrônica de Varredura foi analisado o desenho estrutural dos implantes. Para a análise da distribuição de tensão foram confeccionados oito modelos em resina fotoelástica com dimensões de 40 mm x 10 mm de base e 30 mm de comprimento. Dois implantes para cada grupo foram posicionados e fixados no interior dos modelos fotoelásticos. Uma vez verificada a ausência de tensões nos oito modelos foram iniciados os ensaios. Quatro modelos dos diferentes grupos receberam cargas verticais e quatro receberam cargas oblíquas de 7,5N. Por meio do polariscópio circular pertencente ao laboratório de Materiais Dentários e Prótese da USP-Riberão Preto, foi possível visualizar as franjas de tensões geradas nos modelos. Cada seqüência foi fotografada, sendo mantida a mesma distância focal em todos os ensaios. Os resultados obtidos foram analisados por grupos. O Grupo I, implante de hexágono interno longo com porção cervical polida, topo das roscas arredondadas, passos das roscas contínuas, espirais angulados e configuração cônica, apresentou concentração das tensões na região apical, quando submetida à carga vertical e oblíqua. O Grupo II, implante de hexágono externo, porção cervical polida, topo das roscas em forma de "v", passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões na região apical, médio e cervical do implante quando submetida à carga vertical e oblíqua. O Grupo III, implante com hexágono interno, porção cervical polida, topo das roscas em forma cônica, passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. O Grupo IV, implante com sistema cone morse, ombro cervical inclinado, platô ou barbatanas, topo do platô quadradas, passos do platô descontinuais, e configuração cilíndrica, distribuiu as tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. Baseado nos resultados obtidos e dentro da metodologia deste estudo conclui-se que: O grupo I, de configuração cônica concentrou a distribuição das tensões em região apical. Os grupo II, III e IV, de configuração cilíndrica, distribuíram as tensões com intensidade e localização similares nos terços apical médio e cervical. O presente estudo evidenciou haver diferenças na distribuição das cargas de um tipo de implante para outro, levando acreditar que essas diferenças possam ter relação com o desenho das roscas e platô. / Abstract: The meaning of this study was analyze on 4 dental implants brands the influence of its thread design on tensions distribution generated thru photoelastic models, after applying a 7.5N load on vertical and oblique directions. Twelve implants, organized in four groups had been selected: I.) Máster Conect Cônico1 4.3 x 13 mm; II.) Titamax Ti Medular2 3.75 x 13 mm; III.) 4,0 Colosso3 RC x 13mm; IV.) Bicon Uncoated Implant4 3.5 x 11mm, being in each group, three dental implants of the same commercial brand. The structural designs of the implants were analyzed with Electronic Microscopy Sweepings. For the tension distribution analysis, eight models had been confectioned in photoelastic resin with 40mm x 10mm base dimensions and 30 mm of length. Two implants of each group had been located and fixed in the interior of photoelastic models. Once verified the absence of tensions in the eight models the analysis were started. Four models of the different groups had received 7.5N load on vertical and four received this same load on oblique direction. By means of the circular polariscope developed in the Dental Materials and Prostheses laboratory the Ribeirão Preto Dental School (USP/RP), it was possible to visualize the tensions fringes generated in the models. Each sequence was photographed, being kept the same focal distance in all the assays. The gotten results had been analyzed by groups. Group I., implants with long internal hexagon and polishing cervical portion, top of rounded off threads, angled steps of continuous threads, spirals and conical configuration, presented tensions concentration on the apical region, when submitted to the vertical and oblique load. Group II, implants with external hexagon, polishing cervical portion, top of threads in form of v, angled steps of continuous threads, spirals and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions of the dental implants, when submitted to the vertical and oblique load. Group III., implants with internal hexagon, polishing cervical portion, top of threads in conical form, steps of threads continuous, spirals angled and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions . Group IV, implants with cone morse system, inclined cervical shoulder, square shaped threads, fin or plateau, angled plateau steps discontinuous, and cylindrical configuration, distributed the tensions on the apical, medial and cervical regions after the application of vertical and oblique loads. Based in the results gotten and respecting the limitations of this study it can be concluding that: Group I. with conical configuration, the tension distributions is concentrated on the apical region. Groups II, III and IV, with cylindrical configuration, had distributed the tensions with similar intensity and localization on the apical, medial and cervical regions. In the present study it is evidenced to have differences in the distribution of loads on the dental implants analyzed, being not evident that these differences have relation with the threads design. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
739

Influência de fotoiniciadores alternativos na durabilidade da união, adaptação marginal e propriedades físico-químicas de resinas adesivas experimentais fotoativadas por LEDs / Influence of alternative photoinitiators on bond durability, marginal adaptation and physical-chemical properties of experimental adhesive resins photocured by LEDs

Souza Júnior, Eduardo José Carvalho de, 1985- 25 August 2018 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T16:27:57Z (GMT). No. of bitstreams: 1 SouzaJunior_EduardoJoseCarvalhode_D.pdf: 1265761 bytes, checksum: 1e110af2f222e502411203feb253160f (MD5) Previous issue date: 2014 / Resumo: O objetivo neste estudo foi analisar o efeito de diodos emissores de luz (LEDs) nas propriedades físicas, químicas, resistência da união (RU), adaptação marginal (AM) e na durabilidade de restaurações realizadas com adesivos experimentais contendo diferentes fotoiniciadores. Uma resina modelo contendo uma mistura de BisGMA/HEMA (60/40 em peso) e dimetil amino etil metacrilato (co-iniciador) foi preparada com os diferentes fotoiniciadores: CQ (Canforoquinona), PPD (1-Fenil-1,2-Propanodiona) e BAPO (Óxido bis-alquil fosfínico), além da associação entre eles. As amostras foram fotoativadas por duas fontes de luz LED, uma de 2° geração (Radii Cal, SDI) e outra de 3° geração (Bluephase G2, Ivoclar Vivadent). A irradiância foi aferida a partir de medidas em potênciômetro e a densidade energética foi padronizada em 48J/cm2. As propriedades avaliadas foram o grau de conversão (GC), cinética de polimerização (CI), análise da permeabilidade dentinária (PMD), sorção (SO) e solubilidade (SL), resistência flexural (RF), módulo flexural (MF) e amarelamento (YL). Para o teste de RU, o ensaio de microtração foi realizado em dentina plana de 70 molares humanos, avaliados após 24 horas e após 1 ano de armazenamento em água a 37ºC. A AM foi mensurada por meio de réplicas das margens superficial e interna de 70 molares humanos, analisadas em microscopia eletrônica de varredura (MEV). Os ensaios de GC, PMD, SO, SL, RF, MF e AM foram submetidos à análise de variância dois fatores, enquanto a RU foi submetida à análise de variância dois fatores (fotoiniciadores e fontes de luz), com medidas repetidas no tempo. Após, todas as médias foram comparadas pelo teste de Tukey ('alfa' = 5%). Os adesivos contendo os fotoiniciadores alternativos, em especial BAPO e BAPO/amina monstraram maior potencial de polimerização, evidenciado pela cinética de conversão. Ainda, os fotoiniciadores alternativos promoveram melhor selamento dentinário, sorção e solubilidade similares e propriedades físico-químicas com melhor desempenho quando comparados aos adesivos convencionais contendo CQ. Em relação à resistência de união, os adesivos contendo BAPO promoveram os melhores desempenhos em até um ano de degradação hidrolítica / Abstract: The aim of this study was to evaluate the effect of light emitting diodes (LEDs) on the physical-chemical properties, bond strength (BS) and marginal adaptation (MA) of experimental adhesives containing diferent photo-initiators. A model resin containing a mixture of BisGMA/HEMA (60/40 wt%) and DMAEMA (co-iniciator) was prepared using different photo-initiators: CQ (Camphorquinone), PPD (1-Phenyl-1,2-Propanedione) e BAPO (Bisalquylphosphine oxide) and their association. The specimens were photoactivated by two LEDs, one monowave (Radii Cal, SDI) and other polywave (Bluephase G2, Ivoclar Vivadent). Irradiance was measured in potenciometer and the energy dose was standardized. The following properties were analyzed: degree of conversion (DC) and for the curing kinetics (CI), dentin permeability (DPM), water sorption (SO), water solubility (SL), flexural strength (FS), flexural modulus (FM) and yellowing (YL). For the BS test, the microtensile test was realized in 70 molars with planned dentin, immediately or after 1-year of water storage. The MA, superficial and internal marginal adaptation measurements were realized by epoxy replicas of the bonded margins using the scanning eléctron microscopy. DC, DPM, SO, SL, FS, FM and AM were submitted to a two-way ANOVA and BS to a two-way repeated measurement ANOVA. Next, the analyzes were submitted to the Tukey¿s test ('alfa' = 5%). The adhesives containing the alternative photoinitiators, such as BAPO and BAPO/amine showed a higher curing potential, promoted by the curing kinetics. Moreover, these alternative photoinitiators showed a better dentin sealing, with similar sorption and solubility values and high physical-mechanical properties when compared to the other groups based in CQ. In relation to the bond strength, the BAPO containing adhesives promoted higher performance even after 1-year of hydrolytic degradation / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
740

Influencia de agentes cimentantes na resistencia a tração de coroas totais fundidas, fixadas em dentina e nucleos metalicos

Prates, Luiz Henrique Maykot 14 September 1999 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T17:22:10Z (GMT). No. of bitstreams: 1 Prates_LuizHenriqueMaykot_M.pdf: 4937964 bytes, checksum: 1759111268df7345a8f2609a47b24c1d (MD5) Previous issue date: 1999 / Resumo: O propósito do estudo foi avaliar o comportamento de 4 agentes cimentantes, em relação à resistência à remoção, por tração, de coroas totais fundidas, fixadas sobre preparos em dentina e núcleos metálicos. Foram utilizados 28 molares humanos, inferiores e recém-extraídos. Após a confecção de um orifício retentivo, as raízes dos dentes foram embutidas em resina acrílica ativada quimicamente, contida em tubos de PVC. Nas porções coronárias foram confeccionados preparos para coroas totais, com ponta diamantada n. 4103, sob refrigeração, acoplada ao torno mecânico. Os preparos em dentina, com expulsividade de 8°, foram reproduzidos em liga de prata Pratalloy (Degussa), através de técnica de fundição. Após a limpeza dos núcleos metálicos, com jato de óxido de alumínio, os preparos foram moldados com silicona por adição Express (3M), sendo o enceramento os padrões das coroas, realizado em troquéis de gesso tipo IV Vel Mix (Kerr). As 56 coroas totais, com uma alça suporte oclusal, foram confeccionadas em liga de paládio-prata Pors-on 4 (Degussa), através de técnica de fundição de rotina. Após a limpeza das coroas, com jato de óxido de alumínio, os corpos-de-prova em dentina e em núcleos, foram divididos aleatoriamente em 8 grupos com 7 réplicas (4 grupos em dentina e 4 em núcleos). As coroas dos grupos 1,2, 3 e 4 foram fixadas nos preparos em dentina, respectivamente, com os cimentos de fosfato de zinco (Cimento de Zinco - SS White); de ionômero de vidro convencional (Ketac Cem - ESPE); de ionômero de vidro modificado por resina (Vitremer - 3M); e, resinoso com adesivo (Cimento de Resina com Scotchbond Multi-Uso Plus - 3M). As coroas dos grupos 5, 6, 7 e 8 foram fixadas nos núcleos metálicos, respectivamente, com os mesmos cimentos. Os corpos-de-prova foram armazenados em 100 % de umidade relativa, a 37° C, durante 24 horas, sendo em seguida submetidos a 500 ciclos. ... Observação: O resumo, na integra, poderá ser visualizado no texto completo da tese digital / Abstract: The purpose of this study was to evaluate the behaviour of 4 dental cements, to the removal strength, under tensile, of full cast crowns luted to dentin, and cast metallic cores. Atier the preparation of a retentive orifices, the roots of twenty eight teeth were embedded in resin within PVC tubes. Then, the coronal portions of the teeth were prepared to receive full crowns, using a 4103 diamond bur, under refrigeration, held on a lathe. Dentin preparations, with 8 degrees of tapering, were duplicated with silver alloy (Pratalloy - Degussa), using a routine casting technique. The mettalic cores were cleaned with aluminum oxide blast, the preparations were cast with Express (3M) vinyl polysiloxane, and the patterns were waxed on type IV stone dies (Vel Mix - Kerr). The fifiy six full crowns, with an occlusal support loop, were ma de with palladium-silver alloy (Pors-on 4 - Degussa) using a routine casting technique. The mettalic crowns were cleaned with aluminum oxide blast, and then the test specimens on dentin and in cores were randomly assigned to 8 groups of 7 units each (4 groups in dentin and 4 groups in cores). The crowns of Groups 1, 2, 3 and 4 were luted to the preparations in dentin, respectively, with zinc phosphate (SS White), conventional glass ionomer (Ketac Cem ESPE), resin-modified glass ionomer (Vitremer - 3M) and resin with adhesive (Resin cement and Scotchbond MP Plus - 3M) cements. The crowns of Groups 5, 6, 7 and 8 were luted in metallic cores, respectively, with the same cements. All samples were stored at 370 C, in 100 % relative humidity, for 24 hours. ... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Materiais Dentários

Page generated in 0.1315 seconds