• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 53
  • 36
  • 20
  • 14
  • 10
  • 9
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

A importância de alguns adesivos dentais e de vários tratamentos da superfície sobre a dentina humana in vitro. Análise da resistência adesiva por micro-cisalhamento / The relevance of some dental adhesives and different surface instrumentations on human dentin (in vitro). Micro-shear bond strength analyses

Manoel Roberto de Paula Macedo 05 December 2008 (has links)
O objetivo deste trabalho foi estudar a ação sobre a dentina humana (in vitro) de vários tratamentos de superfície: Lixa, IADR-GM, CVDt e CVDi e de alguns adesivos dentais: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL) avaliando: rugosidade e resistência adesiva por micro-cisalhamento. Foram utilizados 72 terceiros molares hígidos que foram divididos ao meio. As superfícies oclusais das 144 metades dentais foram removidas e padronizadas com Lixa #600. Após receberem os tratamentos de superfície citados, foi avaliada a rugosidade média superficial (Ra) da dentina. Em seguida realizou-se a hibridização e a confecção dos cilindros de resina composta (RC) para finalizar o preparo dos corpos de prova (cps). Após armazenagem de 24h em água destilada a 370C realizou-se o teste de micro-cisalhamento com velocidade de deslocamento de 1mm/min. Os resultados foram submetidos a testes de analise estatística (ANOVA) onde foi comprovado que a menor Ra foi encontrada nas superfícies instrumentadas com Lixa #600 seguida pelo CVDi, IADR-GM que apresentaram rugosidade intermediaria e se igualaram e pelo CVDt que produziram as superfícies mais rugosas. Já para o tratamento de superfície, o CVDi foi que apontou os piores valores de resistência de adesão que com Lixa e IADR-GM. Nos resultados para os adesivos, o PL apresentou valores de resistência à união inferiores ao SB e CF que se igualaram. Já para a interação entre os tratamentos de superfície e os adesivos não houve diferenças estatisticamente significantes entre os grupos tratados com Lixa #600, IADR-GM e CVDt e hibridizados com SB ou CF. Concluiu-se: que a Ra produzida em dentina pelo CVD variou de acordo com o tipo de movimento (CVDt produz maior rugosidade que o CVDi); que não foi possível estabelecer uma correlação entre Ra e valores de resistência adesiva; que o PL apresentou valores de resistência à adesão inferiores aos obtidos pelos adesivos SB e CF; que a interação dos tratamentos Lixa, IADR-GM e CVDt com os três adesivos (SB, CF, PL) mostrou valores mais altos para o SB e CF que se igualaram e menores para o PL; que o fator tratamento não produziu diferença de resistência adesiva para o adesivo CF e o mesmo ocorreu com o PL. / The aim of this in vitro study was to evaluate the micro-shear bond strength and the roughness to human dentin using different instrumentations (SiC #600, diamond rotary bur, CVDt and CVDi) and three dentin adhesive/composite resin systems: Adper Sigle Bond 2 (SB), Clearfil SE Bond (CF) e Adper Prompt L-Pop (PL). Seventy-two third molars were split in the middle. The oclusal third from the one hundred and forty and four halves were removed and standardized using the SiC #600. After the prepared surfaces, which were analyzed the roughness average (Ra) with a surface perfilometer and hybridization. The specimens were then stored in distillated water for 24 hours at 370C. The specimens were then were attached to a micro-shear apparatus and subjected to a micro-shear strength test at a crosshead speed of 1mm/min until failure occurred. The two-way ANOVA indicated that there was significant differences in average roughness between the instrumentations which SiC #600 was the smoothest surface. No differences were detected between dentin surface prepared with diamond bur and CVDi (intermediate in the roughness assessment) and the CVDt gave the roughest surface. The bond strengths varied slightly, though dentin instrumentations with CVDi showed the lowest values than the surfaces prepared with SiC #600 and diamond bur. The bond strengths varied slightly, though adhesives, PL showed lower micro-shear bond strength than SB and CF, which were no significant relevance. The interaction of SiC #600, diamond bur and CVDt using SB and CF showed no significant difference in micro-shear bond strength and higher than PL. The instrumentation showed no significant differences in micro-shear bond strength using CF and PL.
52

Influência da irradiação com laser de Er, Cr:YSGG na resistência de união de sistemas adesivos em esmalte e dentina / Er,Cr:YSGG laser irradiation influence on enamel and dentin bond strength of adhesive systems

Sergio Brossi Botta 04 June 2007 (has links)
Este trabalho teve o objetivo de avaliar a resistência adesiva de sistemas adesivos baseados no condicionamento prévio com ácido fosfórico (etch-and-rinse) e auto-condicionantes (de um e dois passos) ao substrato dental, submetido a diferentes condições de irradiação com laser de Er,Cr:YSGG. Amostras de esmalte e dentina foram obtidas do terço médio da face vestibular de 216 incisivos bovinos, divididos aleatoriamente em 18 grupos (n=12), de acordo com o substrato, (esmalte e dentina), sistema adesivo (etch-and-rinse, auto-condicionante de um passo e auto-condicionante de dois passos) e condições de irradiação (sem irradiação ? controle, irradiado com refrigeração ar-água e irradiado sem refrigeração ar-água). Em seguida foi realizada inclusão e polimento, sob refrigeração, com lixas de carbeto de silício de granulação decrescente 180, 320, 400 e 600 (por um minuto para padronização da camada de esfregaço). Para os grupos irradiados com laser de Er,Cr:YSGG (?=2,79 ?m, taxa de repetição de 20 Hz), com densidade de energia de 2,8 J/cm2, 12,5 mJ por pulso, potência média de 0,25W, com a ponta S75 de diâmetro de 750 ?m a 1 mm da superfície do substrato. A condição de refrigeração da irradiação foi realizada com 11 mL/min. Os corpos-de-prova foram confeccionados com a resina composta Filtek Z250, em forma de cone invertido para realização do teste de resistência adesiva. Após 24 h de armazenagem em água destilada a 37ºC, fez-se o ensaio de tração a 0,5 mm/min. Os dados foram comparados estatisticamente pelo método de ANOVA com significância de 5%. Os resultados obtidos mostraram que para o tecido esmalte foi observada diferença estatisticamente significante para os fatores adesivo e condições de irradiação empregadas, sem significância para a interação entre os fatores. A resistência de união do sistema adesivo auto-condicionante de dois passos e do sistema adesivo etch-and-rinse apresentam desempenho semelhante, sendo superiores ao sistema adesivo auto-condicionante de passo único. Ainda para esmalte, o efeito das condições de irradiação mostrou que os grupos sem irradiação com laser de Er,Cr:YSGG apresentaram maior resistência adesiva do que os grupos irradiados com refrigeração e sem refrigeração. Para o substrato dentina, houve diferença estatisticamente significante para os fatores de variação principais: sistemas adesivos, condição de irradiação com laser de Er,Cr:YSGG e para a interação adesivo X condição de irradiação. Quanto à comparação entre os sistemas adesivos testados na condição sem irradiação, os sistemas adesivos auto-condicionantes, de dois passos e o de um passo, não foram estatisticamente diferentes entre si, porém ambos forneceram resultados de resistência adesiva estatisticamente menores do que o sistema adesivo etch-and-rinse. Para as condições de irradiação com laser de Er,Cr:YSGG, com refrigeração e sem refrigeração, obteve-se valores de resistência adesiva maiores para o sistema auto-condicionante de dois passos do que para os demais sistemas. Deste modo, conclui-se que a irradiação com laser de Er,Cr:YSGG reduz a adesão ao esmalte independentemente do sistema adesivo utilizado e da condição de irradiação. Adicionalmente, observa-se que a irradiação de dentina com laser de Er,Cr:YSGG somente não altera a resistência adesiva do sistema auto-condicionante de dois passos, sendo deletéria aos demais adesivos testados. / The aim of this study was to assess the bond strength to dental substrate of adhesives based on previous etching with phosphoric acid (etch-and-rinse) and self-etching (one- and two-step) under different conditions of Er,Cr:YSGG laser irradiation. Enamel and dentin samples were obtained from the middle third of the buccal face of 216 bovine incisors, randomly divided in 18 groups (n=12), according to the substrate (enamel and dentin), adhesive system (etch-and-rinse, one-step self-etching and two-step self-etching) and irradiation condition (without irradiation ? control, irradiated with cooling, and irradiated without cooling). Next, the samples were included and polished, under cooling, with silicone carbide abrasive papers of decreasing grit #180, 320, 400 and 600 (for one minute to standardize the smear layer). For the irradiated groups with Er,Cr:YSGG laser, an energy density of 2.8 J/cm2, 12.5 mJ per pulse, mean power of 0.25W was selected. During laser irradiation, cooling was performed with 11 mL/min. Inverted cone-shaped test specimens were built-up with resin composite Filtek Z250, for performing the bond strength test. After 24 h storage in distilled water at 37ºC, the tensile test was performed at 0.5 mm/min. The results obtained show, for enamel, statistically significant difference for the factors adhesive and irradiation conditions used, without significance for the interaction among the factors. The bond strength of the 2-step self-etching and the etch-and-rinse adhesive system presented similar performance, being superior to that of one-step self-etching system. For enamel, the effect of the irradiation conditions showed that the groups without Er,Cr:YSGG laser irradiation presented higher bond strength than the groups irradiated with and without cooling. For the dentin substrate there was statistically significant difference for the main variation factors: adhesive systems, condition of Er,Cr:YSGG laser irradiation and for the interaction adhesive X irradiation condition. As regards the comparison among the adhesive systems tested under the condition without irradiation, the one-step and two-step self-etching adhesive systems did not differ statistically between them, but both provided statistically lower bond strength results than the etch-and-rinse adhesive system. For the condition of Er,Cr:YSGG laser irradiation with and without cooling, higher bond strength values were obtained for the two-step self-etching system than for the other systems. Therefore, it was concluded that Er,Cr:YSGG laser irradiation reduces the bond strength to enamel irrespective of the adhesive system used and the irradiation condition. Furthermore, it was observed that dentin irradiated with Er,Cr:YSGG laser did not alter the bond strength of the two-step adhesive system only, and it was deleterious to the other adhesives tested.
53

Uso de ferramentas da metodologia de manutenção produtiva total e metodologia Lean Sigma para aumento de produtividade. Estudo de caso na área de cremes dentais da empresa GlaxoSmithKline Brasil Ltda / Using tools of Total Productive Maintenance methodology and Lean Sigma methodology to increase productivity. Case study in the area of toothpastes GlaxoSmithKline Brazil Ltda

Aguiar, Fábio Corrêa Martins de January 2013 (has links)
Made available in DSpace on 2016-06-23T12:15:51Z (GMT). No. of bitstreams: 2 12.pdf: 3444028 bytes, checksum: 73c0e8984bffa4bb547494ec30407d6f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2013 / Made available in DSpace on 2016-07-05T22:37:59Z (GMT). No. of bitstreams: 3 12.pdf.txt: 204813 bytes, checksum: 9eae4f603bf69f1c3e4907b919ce4332 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 12.pdf: 3444028 bytes, checksum: 73c0e8984bffa4bb547494ec30407d6f (MD5) Previous issue date: 2013 / A concorrência no setor farmacêutico é intensa e os produtos farmacêuticos possuem tempo de ciclo reduzido quando comparado com os grandes investimentos de P&D. Para concorrer neste setor, as indústrias estão sempre com foco em melhorar a eficiência dos processos de manufatura utilizando muitas vezes equipamentos complexos, modernos e automatizados com foco na produção para atingir as metas. Neste contexto, o objetivo deste trabalho é demonstrar o melhor controle da produção utilizando como base a metodologia de Manutenção Produtiva Total da Produção buscando a maximização da eficiência dos equipamentos e recursos disponíveis, utilizando várias ferramentas dentre elas a Overall Equipment Effectiveness (OEE) conhecida como eficiência global dos equipamentos de produção. Esta ferramenta permite monitorar o desempenho da linha de produção, identificar os principais gargalos, monitorar os índices de OEE, sugerir ações de melhoria no processo. Na análise de resultados do OEE ficou evidenciado que os setups, troca de máquina, representavam grandes desperdícios ao processo produtivo sendo então utilizado o SMED para redução destes tempos e conversão em tempos reais de produção. Também a utilização e implementação de outras ferramentas de apoio à implementação, manutenção e sustentação da produtividade como: trabalho padrão, análises de causa-raiz, guia de solução de problemas, criação de um conselho de OEE, educação e treinamento, Gemba, Kaizen, 5 s, trabalho padrão para liderança, controles visuais, reuniões de níveis de responsabilidade baseadas no sistema lean de gerenciamento de produção (Tier 1, Tier 2, Tier 3 e Tier 4). O conjunto destes resultados acaba aumentando o lucro, a produtividade e qualidade, reduzindo assim os custos para o setor farmacêutico possibilitando maior competitividade. Neste estudo ficou possível observar que com a implementação destas ferramentas de gerenciamento da produção transformou-se desperdícios envolvidos no processo em tempo real de produção. / The competition in the pharmaceutical industry is intense and the products have reduced life cycles when compared to the large investments in R&D. To compete in this sector is necessary to improve the efficiency of the manufacture processes often using complex, equipment, modern and automated with focus in the production to reach the goals. In this context, the objective of this work is to demonstrate better control of production basis in the use of Total Productive Maintenance seeking to maximize the efficiency of equipments using various tools among them the Overall Equipment Effectiveness. This tooling allows you to improve the acting of the production line, to identify the bottle mouths, monitor OEE index, and suggesting improve actions in the process. Related the results of OEE analysis have been demonstrated that setup represented major wast in the production process so that the tooling SMED was used to reduce the time of change on the machine and convertion on the productive time. Beyond use of OEE another tools are used to support the implementation, maintenance and support the productivity as standard work, root cause analysis, troubleshooting, creating of OEE Council, education & training, gemba, Kaizen, 5 S, leader standard work, visual control, tier accountability based on the Lean Methodology (Tier 1, Tier 2, Tier 3 and Tier 4). The group of these results ends up increasing the profit to the productivity, quality, and cost reduction to the pharmaceutical industry enabling greater competitiveness. In this study was possible to observe the implementation of managament production tooling that’s convert waste time in an production real time.

Page generated in 0.042 seconds