41 |
Análise tridimensional por elementos finitos da biomecânica de próteses implantossuportadas = influência da carga oclusal, tipo de conexão, angulação dos implantes e simplificações de modelagem / Tridimensional finite element analysis of biomechanics of implant-supported prosthesis : influence of occlusal load, implant connection system, implant tilting and modeling simplificationsTakahashi, Jessica Mie Ferreira Koyama 17 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:47:37Z (GMT). No. of bitstreams: 1
Takahashi_JessicaMieFerreiraKoyama_D.pdf: 2653820 bytes, checksum: 9f12264a20dcd2dbebcecc54655dd900 (MD5)
Previous issue date: 2011 / Resumo: O objetivo nos presentes estudos foi avaliar, por meio de análise tridimensional de elementos finitos, os efeitos nos valores e padrões de distribuição de tensões de modelo virtuais de próteses implantossuportadas na presença de: 1) Simplificações de modelagem das geometrias de superfícies com rosca; 2) Variação do padrão de cargas oclusais e tipo de conexão de implantes; 3) Inclinação do implante e necessidade do uso de componentes angulados. No primeiro estudo foram confeccionados modelos virtuais simulando a interface entre o osso de uma seção posterior de mandíbula e um implante, e a interface entre o componente protético e o parafuso protético. As interfaces foram simuladas com variação da geometria das roscas e tipo de contato entre as estruturas. Os modelos da interface osso/implante receberam carga oblíqua de 180N, e os da interface abutment/parafuso carga de 41N. Foi observado, na interface implante/osso, que os valores de tensão variam de acordo com a geometria modelada e o contato entre as estruturas e que tensões artificialmente elevadas podem ser observadas em regiões pontuais. Na interface abutment/parafuso, a geometria modelada não influenciou os resultados obtidos. No segundo estudo, foram confeccionados modelos virtuais simulando próteses fixas suportadas por implantes de conexão do tipo hexágono externo, hexágono interno, e cone morse; submetidos à aplicação de cargas axiais ou oblíquas sobre a superfície da infraestrutura modelada (180N em primeiro pré-molar e primeiro molar; 280N em segundo pré-molar). Foi observado que mediante aplicação de cargas oblíquas os valores de tensão apresentaram aumento significativo, e que o local de concentração das tensões também foi alterado para regiões mais inferiores nas estruturas avaliadas. Os modelos de montagens com implantes de conexão interna apresentaram padrão de distribuição de tensão mais favorável aos tecidos de suporte. No terceiro estudo, modelos virtuais de próteses fixas implantossuportadas foram simulados com implantes distais posicionados de maneira inclinada. Os modelos foram confeccionados utilizando conexões do tipo hexágono externo e cone morse, sendo utilizados componentes com 17o de angulação. Os modelos foram submetidos às mesmas condições de carregamento citadas no estudo anterior. Foi observado que mediante inclinação dos implantes distais, não há diferença significativa nos valores de tensão nos tecidos de suporte, havendo apenas alteração na área de concentração de tensão. A tensão foi mais concentrada no osso trabecular ao redor do implante posicionado verticalmente. As conexões avaliadas apresentaram valores de tensão semelhantes nos tecidos de suporte, enquanto os modelos de conexão cone morse apresentaram maior tensão nos componentes protéticos. Desta maneira, concluiu-se que: 1) a simplificação da geometria de roscas para análise utilizando o método de elementos finitos gera valores e padrão de distribuição de tensão confiáveis; 2) a aplicação de cargas oblíquas gera aumento significativo na tensão nas estruturas ósseas; 3) o tipo de conexão do implante pode interferir na tensão em componentes protéticos e osso; 4) a inclinação de implantes não gera maior tensão nos tecidos de suporte. / Abstract: The aim of the following studies was to evaluate with finite element analysis, the effect on stress values and distribution pattern of virtual models of implant-supported prostheses in the presence of: 1) Modeling simplification of threaded surfaces geometry; 2) Variation of occlusal load pattern and implant connection type; 3) Implant inclination and the use of angled abutments. On the first study, virtual three-dimensional models were obtained simulating the interface between bone of a posterior section of the lower jaw and a dental implant, and the interface between an abutment and a prosthetic screw. The screwed interfaces were simulated with variation of thread geometry and contact between the structures. Bone/implant models were loaded with 180N oblique force, while abutment/screw models were loaded with 41N force. It was observed, on the implant/bone interface that stress values depend of the modeled geometry and the amount of contact between the surfaces; and that artificially high stress might be observed in located areas. On the abutment/screw interface, modeled geometry did not influence the results. For the second study, virtual models were obtained simulating three-element fixed partial dentures supported by two implants of external-hexagon, internal-hexagon or morse-taper connection. The models were submitted to axial or oblique loading (180N on first premolar and first molar, 280N on second premolar). It was observed that oblique loading significantly increased stress values, and changed stress concentration areas. Also, the models with internal connection implants presented stress distribution pattern more favorable to the supporting structure. On the third and final study, virtual models of implant-supported frameworks were obtained with inclined distal implants with external-hexagon or morse-taper connection and 17o angled abutment. All models were submitted to the same loading conditions previously described. It was observed that inclined implants do not significantly increase stress on supporting tissue, with changes only on stress concentration area. Higher stress was concentrated at trabecular bone around the straight implant. The evaluated connection systems presented similar stress values on the supporting tissue, while morse-taper models presented higher stress on the prosthetic components than the external-hexagon. Thus, it was concluded that: 1) finite element models, with simplified representation of the thread interface present reliable stress values and distribution patterns; 2) oblique loading of the framework increases stress values on the supporting tissues; 3) implant connection system may interfere on stress on prosthetic components and bone; 4) implant inclination does not increase stress on supporting tissue. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
42 |
Análise tridimensional por elemento finito do comportamento biomecânico de próteses totais fixas implantossuportadas = efeito do tipo de conexão protética, cargas oclusais e número de implantes / Three-dimensional finite element analysis of biomechanics of implant-supported fixed prostheses : effect of connection system, occlusal load, and number of implantsDayrell, Andreza Costa 18 August 2018 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T05:15:14Z (GMT). No. of bitstreams: 1
Dayrell_AndrezaCosta_D.pdf: 2283239 bytes, checksum: 78a83ffa41273620963821d103b0e585 (MD5)
Previous issue date: 2011 / Resumo: A proposta neste estudo foi analisar a distribuição de tensão pelo método de elementos finitos tridimensional em próteses totais fixas inferiores implantossuportadas e região óssea peri-implantar, utilizando-se dois tipos de conexão implante-abutment externa e interna, correlacionadas ao efeito de cargas axiais e número de implantes. Modelos virtuais foram elaborados simulando uma prótese total fixa implanto suportada mandibular, de acordo com o protocolo Branemark, tendo como fatores de estudo as conexões implant-abutment Cone Morse (CM) e Hexágono Externo (HE); quatro e cinco implantes; cargas axiais 100 N bilateral, 300 N bilateral e unilateral. As condições de análise foram: 1. Próteses fixas com conexão interna Cone Morse (CM) submetidas à seis condições experimentais constituindo os modelos M1, M2 e M3 com quatro implantes e cargas de 100 N e 300 N, respectivamente; os modelos M4, M5, e M6 com cinco implantes e cargas similares; 2. Próteses fixas com conexão externa Hex Externo (HE), submetidas às mesmas condições; 3. Comparação entre os dois sistemas de conexão. Os resultados de deformação óssea (??), sob efeito de cargas axiais de 100 N, distribuíram-se homogeneamente nos grupos com CM e concentraram-se nos implantes distais nos grupos com HE. Sob efeito de cargas axiais de 300 N, a distribuição de tensão acompanhou a mesma tendência anterior, com aumento de deformação no osso (??) e implantes (MPa) cerca de 1,5-2 vezes para os grupos com CM e 3 vezes para os grupos com HE. Dentro das condições do estudo concluiu-se que: 1. sob efeito de cargas axiais de 100 N o uso das duas conexões implante-abutment Cone Morse e Hexágono Externo é bem indicado; 2. sob efeito de cargas axiais de 300 N a conexão Cone Morse apresenta melhor indicação; 3. cinco implantes não representam benefício relevante em relação à quatro; 4. com o sistema de conexão Cone Morse, a solicitação mecânica distribui-se por todos os implantes e região óssea, com o sistema Hexágono Externo, concentra-se nos distais e região óssea circundante; 5. a distribuição de tensão na infraestrutura protética é similar com os dois sistemas de conexão, apresentando resistência mecânica satisfatória com a conexão Hexágono Externo e cargas axiais de 100 N e insuficiente para ambas as conexões sob cargas axiais de 300 N / Abstract: The purpose of this study was to analyze the stress and strain distribution by three-dimensional finite element method in implant supported fixed prostheses and peri-implantar bone region, using two types of implant-abutment connection internal and external, correlated to the effect of axial loadings and number of implants. Virtual models were developed by simulating a mandibular implant supported fixed prostheses, according to the Branemark protocol, with study factors: implant-abutment connection Morse taper (MT) and External hexagon (EH); four or five implants; bilateral axial loadings 100 N, bilateral and unilateral axial loadings 300 N. The analysis conditions were: 1. Fixed prostheses with internal connection Morse taper interface (MT) simulating six experimental conditions, making the models M1, M2 and M3 with four implants and loads of 100 N and 300 N, respectively; models M4, M5, M6 with five implants and similar conditions; 2. Fixed prostheses with external connection External hexagon interface (EH), submitted to same conditions; 3. Comparison between the two connection systems. The results of von Mises stress and bone strain, under effect of 100 N axial loadings, were distributed evenly for all implants for groups with MT, focused mainly on the distal implants for groups with EH. Under effect of 300 N axial loadings, the stress and strain distribution followed the same tendency, with values increased of 1.5-2 times for the MT group and 3 times for EH groups. Within the analysis conditions the study concluded that: 1. under effect of axial loadings of 100 N, the use of two implant-abutment connections MT and EH can be well indicated; 2. under effect of axial loadings of 300 N, the Morse taper connection provides a better indication; 3. Five implants do not represent relevant benefit over four; 4. with Morse taper connection system, the mechanical stress is distributed for all implants and bone area, with the External hexagon, focuses on the distal region and surrounding bone; 5. the stress distribution in prosthetic infrastructure is similar with the two connection systems and the mechanical strength is satisfactory for groups with prosthetic connection EH and 100 N axial loadings, and insufficient for both prosthetic connections under effect of 300 N axial loadings / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
43 |
Efeito do numero de ciclos de união e separação dos componentes sobre a retenção de sistemas de encaixes para overdentures / Retention force and fatigue strength of overdenture attachment systemPigozzo, Monica Nogueira 23 February 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T11:28:23Z (GMT). No. of bitstreams: 1
Pigozzo_MonicaNogueira_M.pdf: 2354060 bytes, checksum: cc00aca1a1073cf363d5005a5ed1a5d8 (MD5)
Previous issue date: 2007 / Resumo: Este trabalho teve como objetivo avaliar o efeito do número de ciclos de união e separação dos componentes sobre a retenção de 4 sistemas de encaixes para Overdenture do tipo barra-clipe. Foram confeccionados 40 corpos-de-prova, separados em 4 grupos de 10: 1- Conexão Sistema de Prótese (clipe de polímero); 2- Sterngold-Implamed (clipe de polímero); 3- 3i-Implant innovation (clipe metálico); e 4- SIN Sistema de Implante Nacional (clipe metálico). Os corpos-de-prova imersos em saliva artificial foram submetidos ao ensaio de ciclagem mecânica em máquina servohidraúlica MTS-810, realizando-se 5.500 ciclos (união e separação dos componentes) com freqüência de 0,8 Hz. Os valores da força de retenção foram monitorados em 6 registros por meio de ensaio de tração, utilizando o programa Test Work for Test Star com velocidade de 1mm/min, e célula de carga de 1 KN nos períodos: retenção inicial; em 1.100 ciclos de união e separação; 2.200 ciclos; 3.300 ciclos; 4.400 ciclos; e 5.500 ciclos. Os dados obtidos foram submetidos à análise de variância e aplicado o teste de Tukey (p<0,05). Os resultados mostraram que entre os grupos com clipes de polímeros não existiu diferença estatisticamente significante, enquanto os sistemas com clipes metálicos apresentaram diferença estatisticamente significante entre si, exceto após 5.500 ciclos. Os sistemas de retenção da Conexão e 3i apresentaram diferença estatisticamente significante após 4.400 ciclos. Os sistemas de retenção da Conexão e SIN apresentaram diferença estatisticamente significante em todosos ciclos, assim como os da Sterngold-Implamed e SIN. Os sistemas de retenção daSterngold-Implamed e 3i apresentaram diferença estatisticamente significante após 5.500ciclos. Os resultados permitiram concluir que: os sistemas avaliados apresentaram valores de força de retenção considerados satisfatórios em todos os tempos de registro, sendo os mais elevados apresentados pela Conexão e Sterngold-Implamed. Durante o experimento, não ocorreu diminuição nos valores da força de retenção, ou fratura dos componentes, em qualquer sistema avaliado / Abstract: The aim of the present study was to evaluate the effect of the number of insertion and removal cycles on retention force of four Overdenture bar-clip attachment systems. Sample included 40 specimens which were assigned to 4 groups (n=10): 1- Conexão Sistemas de Prótese (polymeric clip); 2- Sterngold-Implamed (polymeric clip); 3- 3i- Implant innovation (metallic clip); and 4- SIN Sistema de Implante Nacional (metallic/metal clip). Specimens immersed in artificial saliva were tested to 5.500 cycles at 0.8 Hz using a servohydraulic machine (MTS-810). During the test, retention force values were recorded 6 times using the tensile test (Test Works for Test Star) at a speed of 1mm/min, with a load cell of 1 KN: initial retention force; at 1100 insertion and removal cycles; 2200 cycles; 3300 cycles; 4400 cycles; and 5500 cycles). Data were submitted to analysis of variance (ANOVA) and Tukey test (p<0.05). No statistically significant difference was observed for the groups using polymeric clips; however, those using metallic clips showed significant difference, except after 5500 cycles. Conexão and 3i attachment systems showed statistically significant difference after 4400 cycles. Comparison between Conexão and SIN Systems and Sterngold-Implamed and SIN demonstrated significant difference at all cycles. Sterngold-Implamed and 3i systems showed statistically significant difference only after 5500 cycles. Results showed that the systems evaluated displayed satisfactory retention force values at all cycling periods tested, with the highest values observed for Conexão and Sterngold-Implamed. No component fractures or reduction in retention force values was found for any of the systems tested. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
44 |
Resistência à remoção por tração de coroas NiCr cimentadas sobre munhões usinados em liga de titânio, irradiados ou não por LASER / Tensile strenght of NiCr crowns cemented upon usinated titanium alloy abutments, LASER irradiated or notFabiane Lopes Toledo 24 May 2007 (has links)
No presente trabalho, usando ensaios de remoção por tração, o objetivo foi avaliar a eficiência de 4 agentes (fosfato de zinco S. S.White, ionômero de vidro Ketac Cem Easymix, resina composta RelayX Luting 2 e resina acrílica especial Panavia 21 TC) usados para fixar coroas totais de NiCr a munhões tronco-cônicos, usinados em liga de Ti-6Al-4V. Dentre os cinqüenta munhões utilizados, 40 permaneceram com sua superfície original altamente lisa (como vieram de fábrica) e foram distribuídos em grupos de 10, para cada agente cimentante; no grupo dos 10 restantes existiu uma modificação por irradiação com LASER e cimentação apenas com fosfato. Os ensaios mecânicos foram realizados em uma máquina universal MTS 810, na velocidade de 0,5 mm/min. A respectiva Análise de Variância (ANOVA) apontou existir diferença significante entre os grupos e o teste de Tukey (p<0,05) também mostrou diferenças significantes entre eles, exceto nas comparações original/fosfato versus original/RelayX e original/fosfato versus original/KetcCem. Para os munhões não-irradiados, o melhor desempenho foi apresentado pela resina Panavia 21 (1.127,996 N); a resina composta RelyX (478,197 N) mostrou comportamento similar apenas ao do fosfato (430,662 N), o qual apresentou desempenho semelhante ao ionômero de vidro KetacCem (227,705 N). A modificação da superfície do munhão fez com que a magnitude da resistência à tração das coroas cimentadas com fosfato aumentasse para 1.514,872 N. / By means of tensile essays, NiCr total crowns were removed from usinated tronco-conical abutments composed by an Ti-6Al-4V alloy; the performance of 4 cementig agents (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelayX Luting 2 composite resin and Panavia 21 TC special acrylic resin) was evaluated. Among a total of 50 abutments, 40 were used with it surface presenting high smoothness (as they come from manufacturer) and distributed in groups of 10 elements, each group for each cementing agent; the other 10 abutments had had its surfaces modified by LASER and were used only with phosphate. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of original/phosphate versus original/ RelayX and original/phosphate versus original/ KetacCem. To non-irradiated abutments, the better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of KetacCem (227.705 N). The referred LASER irradiation promoted an increased resistance to the phosfate, which reached 1,514.872 N.
|
45 |
Análise extensométrica e do desajuste marginal de infra-estruturas implanto-retidas nas configurações linear e compensada com diferentes coifas sob aplicação de cargas axiais e não axiais / Analysis of marginal misfit and strain gauge in implant-supported frameworks using straight line and offset placement with different copings under axial and non-axial loadAbreu, Celina Wanderley de, 1982- 19 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T03:08:59Z (GMT). No. of bitstreams: 1
Abreu_CelinaWanderleyde_D.pdf: 708429 bytes, checksum: e7e9243a443a7387eced5b96c49b0b3c (MD5)
Previous issue date: 2011 / Resumo: O objetivo neste estudo in vitro, foi analisar microscopicamente o desajuste vertical e passivo e quantificar a deformação usando análise de extensometria durante aplicação de carga axial e não-axial em prótese parcial fixa implanto-suportada de três elementos, variando a posição dos implantes, linear (L) ou compensada (C) e o tipo de coifa protética, plástica (P) ou colar metálico (M). Três implantes cone morse posicionados linear e três numa configuração compensada foram inseridos em dois blocos de poliuretano. Pilares microunit foram parafusados nos implantes aplicando torque de 20 Ncm. Coifas plásticas e com colar metálico foram parafusados nos pilares que receberam enceramentos padronizados. Os padrões de cera foram fundidos em liga Co-Cr (n=5) e separados em quatro grupos: G1- L/P; G2- L/M; G3- C/P e G4- C/M. Quatro strain gauges (SG) foram colados na superfície de cada bloco tangencialmente aos implantes. Os parafusos de retenção das supra-estruturas foram parafusados nos pilares com torque de 10 Ncm e, em seguida, foram aplicadas as cargas. A magnitude da microdeformação em cada strain gauge foi registrada em unidade de microdeformação (??). Os níveis de desajuste vertical foram mensurados com todos os parafusos apertados com torque de 10 Ncm e o desajuste passivo com apenas um parafuso apertado. A análise do desajuste foi feita utilizando microscópio óptico com precisão de 0,5 ?m e 120x de aumento. Os dados foram analisados estatisticamente pela ANOVA e teste de Tukey (p<0.05). Não foi observada diferença estatisticamente significativa para desajuste passivo (p>0.05), porém houve diferença no desajuste vertical para o fator configuração (p=0.0257). Na quantidade de deformação por meio da extensometria foi encontrada diferença no fator configuração (p=0.0005). Após o teste Tukey foi observada uma diferença entre L/P (306.1±82.25) e C/P (146.6±93.64). Não houve diferença significante entre carga axial e não axial. Existiu evidência de que a posição offset é capaz de reduzir a deformação em torno do implante. Em adição, o tipo de carga, axial ou não-axial até 2mm não teve influência e o tipo de coifa usado também não interferiu / Abstract: The aim of this in vitro study was microscopically analyzing the vertical and passive misfit and quantify the strain development using strain gauge analysis during axial and non-axial loading in three-element implant-supported FPDs, varying the arrangement of the implants: straight line (L) and offset (O) and the type of prosthetic coping used: plastic (P) or metallic collar (M). Three Morse taper implants arranged in a straight line and three implants arranged in an offset manner were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, using a torque of 20Ncm. Plastic and metallic collar copings were screwed onto the abutments, which received standard wax patterns. The wax patterns were cast in Co-Cr alloy (n=5), making a total of four groups: G1- L/P; G2- L/M; G3- O/P and G4- O/M. Four strain gauges (SG) were bonded on the surface of each block tangential to the implants. The superstructure's occlusal screws were tightened onto the microunit abutments using 10 Ncm torque with a manual torque driver and then an axial load was applied. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (??). An optical microscope, with 0.5 ?m of measurement accuracy and 120x magnification, was used to evaluate the vertical fit with all of the screws tightened to 10 Ncm torque and the passive fit with only one screw tightened to the appropriate torque. The data were analyzed statistically by ANOVA and Tukey's test (p<0.05). There was not statistically significant difference for passive misfit (p>0.05), but a significant difference existed in vertical misfit for the factor of configuration (p=0.0257). A significant difference was also observed for strain for the factor of configuration (p=0.0005). The Tukey's test revealed difference between L/P (306.1±82.25) and O/P (146.6±93.64). There was not statistically significant difference between axial and non-axial load. There was evidence that the offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or non-axial did until 2 mm not have an influence and the type of coping used did not interfere / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
46 |
Precisão de medidas lineares em imagens tomograficasGuedes, Fabio Ribeiro 24 February 2005 (has links)
Orientador: Glaucia Maria Bovi Ambrosano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:10:26Z (GMT). No. of bitstreams: 1
Guedes_FabioRibeiro_M.pdf: 16708948 bytes, checksum: 136372754eec5ecaf8e3293298f9b330 (MD5)
Previous issue date: 2005 / Resumo: Foi identificado o fator de magnificação de tomógrafos convencionais e comparado a mangnificação fornecida pelos fabricantes, e a confiabilidade de medidas lineares das imagens tomográficas corrigidas, quando comparadas às mensurações reais nos segmentos ósseos. Foram utilizadas 16 mandíbulas humanas maceradas edêntulas, e selecionada região correspondente aos incisivos, caninos, pré-molares e molares bilateralmente. Em cada região foram fixados sobre a crista óssea e na região vestibular, um fio ortodôntico com 5,0 milímetros de comprimento, que foi utilizado como guia radiográfico. Os equipamentos utilizados neste trabalho foram os tomógrafos convencionais Quint Sectograph, Orthopantomograph OP100, X Mind TOME, e computadorizados Somatom Esprit com reconstrução multiplanar e Toshiba X vision EX com software Denta Scan. As mandíbulas foram posicionadas nos tomógrafos convencionas conforme as especificações dos fabricantes e obtidas as imagens. Para os tomógrafos computadorizados as mandíbulas foram posicionadas com suas bases perpendiculares ao solo e obtidas as imagens axiais ara posterior reconstrução oblíquo-sagital das regiões. Após obtidas as imagens, foram mensuradas a altura e espessura óssea de cada região, corrigindo-se as medidas com base a ampliação do guia radiográfico e em seguida com o fator de magnificação dado pelo fabricante. As mandíbulas foram seccionadas exatamente nas regiões selecionadas, e realizadas as medidas da altura e espessura óssea, obtendo-se os valores reais por região. As magnificações calculadas, por meio do guia radiográfico dos tomógrafos convencionais, foram comparados pelo teste t, com os fornecidos pelos fabricantes, observando-se diferenças significativas para os três tomógrafos convencionais. A altura e espessura óssea corrigidas pela ampliação do guia radiográfico apresentaram diferenças estatisticamente significativas (p<0,05) pelo teste de Dunnett para as medidas do tomógrafo computadorizado Somatom Esprit quando comparadas com as dimensões reais. A medida da altura óssea corrigida com o fator de magnificação fornecido pelo fabricante demonstrou diferenças para os tomógrafos (p<0,05) com exceção do tomógrafo computadorizado Toshiba X vision EX, e para espessura óssea observou-se diferenças para o tomógrafo Quint Sectograph e Somatom Esprit quando comparados com as dimensões reais (p<0,05). Concluiu-se que as diferenças de magnificação calculadas, comparadas com as fornecidas pelos fabricantes não possuem significância clínica. As mensurações da altura e espessura ósseas foram precisas com exceção das realizadas no tomógrafo computadorizado com reconstrução multiplanar Somatom Sprit / Abstract: The magnification factors of conventional tomography was identified and compared them to the factors provided by the manufacturers, and the reliability of linear measurements achieved on corrected tomographic images, when compared to the real measurements on the bone segments. Sixteen dry edentulous human mandibles were used, and the area corresponding to the incisors, canines, premolars and molars were selected bilaterally. A 5.0-mm long orthodontic wire was fixated on the bone crest and buccal region of each area, to be used as a radiographic guide. The equipments used in this study were the conventional tomography Quint Sectograph, Orthopantomograph OP100, X Mind TOME, and the computerized tomography Somatom Esprit with multiplanar reconstruction and Toshiba X Vision EX with the Denta Scan software. The mandibles were positioned on the conventional scanners following the manufacturers¿ instructions, and the images were obtained. As to the computerized scanners, the mandibles were positioned with their bases perpendicular to the ground, and axial images were achieved for later oblique-sagittal reconstruction of the regions. After achievement of the images, the bone height and thickness of each region were measured, with correction of measurements based on the magnification of the radiographic guide and then according to the magnification factor supplied by the manufacturer. The mandibles were sectioned at the selected areas and bone height and thickness were directly measured, for achievement of the real values for each region. The magnification factors calculated by utilization of the radiographic guide for the conventional tomography were compared to those provided by the manufacturers by the t test, which revealed significant differences for the three conventional scanners. The bone height and thickness with correction according to magnification of the radiographic guide presented statistically significant differences (p<0.05) according to the Dunnett test for the measurements achieved on the computerized tomography Somatom Esprit compared to the real dimensions. The bone height corrected according to the magnification factor provided by the manufacturer demonstrated differences for the scanners (p<0.05), except for the computerized tomography Toshiba X vision EX, with differences in bone thickness for the Quint Sectograph and Somatom Esprit tomography compared to the real dimensions (p<0.05). It was concluded that differences between the magnification factors calculated compared to those provided by the manufacturers do not have any clinical implication; also, measurements of bone height and thickness were reliable, except for those achieved on the computerized tomography with multiplanar reconstruction Somatom Sprit / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
|
47 |
Analise fotoelastica da distribuição de tensões induzidas por infra-estruturas implanto-suportadas apos soldagem a laser ou retificação de cilindrosDamaceno, Alessandra Regina Derogis 02 March 2005 (has links)
Orientador: Mauro Antonio de Arruda Nobilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:53:51Z (GMT). No. of bitstreams: 1
Damaceno_AlessandraReginaDerogis_M.pdf: 1414206 bytes, checksum: c7d213655bfe8d988e6311566b91787d (MD5)
Previous issue date: 2005 / Resumo: Este estudo avaliou comparativamente duas técnicas indicadas para a obtenção de melhor assentamento de próteses implanto-suportadas através da análise fotoelástica. Para isso, foram obtidos dois grupos de infra-estruturas metálicas em titânio construídas sobre uma matriz metálica com forma e dimensões similares ao arco mandibular, sendo: Grupo 1- três infra-estruturas confeccionadas pela técnica da soldagem de borda a laser de cilindros pré-fabricados; Grupo 2- três infra-estruturas fundidas em monobloco e submetidas ao sistema de retificação de cilindros fundidos. Após avaliação em microscopia óptica, apenas a infra-estrutura mais bem adaptada de cada grupo foi submetida à análise fotoelástica variando-se três seqüências de aperto dos parafusos (1/2/3/4/5, 5/4/3/2/1 e 3/2/4/1/5). De maneira adicional, a infra-estrutura representante do grupo 2 foi submetida, após a primeira análise, à secção e soldagem vertical das partes, e reavaliada. Os resultados mostraram formação de maior quantidade de tensões nas seqüências de aperto 1/2/3/4/5 e 5/4/3/2/1, para ambos os grupos analisados. A estrutura submetida à soldagem de borda de cilindros pré-fabricados mostrou melhores resultados, apesar de a mesma apresentar maiores valores de desadaptação (165µm) quando comparada àquela que teve seus cilindros submetidos à retificação de borda antes (54µm) ou após a secção e soldagem vertical (117µm). A seqüência de aperto 3/2/4/1/5 mostrou melhores resultados. Portanto, o grupo dos cilindros submetidos à soldagem de borda induziu melhores resultados principalmente quando associada à seqüência de aperto 3/2/4/1/5 / Abstract: This study evaluated two techniques indicated to obtain implant-supported fixed prostheses with satisfactory passive fit by means of photoelastic analysis. Two titanium casts groups were fabricated in a metallic master cast: Group I ¿ three frameworks fabricated by laser welded cylinder technique and Group II ¿ three frameworks cast in one-piece and submitted to Rectification Cylinder System. After optical microscopy evaluation, only the better-fit framework of both groups was submitted to the photoelastic analysis, testing three screw tightening sequences (5/4/3/2/1; 1/2/3/4/5 and 3/2/4/1/5). Subsequent to the first analysis, the selective framework of Group II was sectioned and laser welded to be submitted to a new evaluation. Results showed superior stress magnitude in 1/2/3/4/5 and 5/4/3/2/1 sequences of both groups, while 3/2/4/1/5 screw tightening sequence presented better stress results of them. Laser welded cylinder framework illustrated better results, even though had showed superior values of misfit (165µm) compared to the rectified framework before (54µm) and after section and vertical laser welded (117µm). Laser welded cylinder group achieved better results mainly allied to 3/2/4/1/5 screw tightening sequence / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
48 |
Implantes de zircônia reforçada com ítria (Y-TZP): avaliação histomorfométrica / Y-TZP dental implants: histomorfometry analysisMartins, Renato 14 November 2013 (has links)
O objetivo do trabalho foi avaliar in vivo a osseointegração de implantes produzidos em zircônia reforçada com ítria (Y-TZP) e compará-los com o implante de titânio usinado e com o de superfície jateada com brushita. Para tanto, nas tíbias de 20 coelhos machos (n=10) e fêmeas (n=10) foram implantadas em uma das tíbias o implante Y-TZP (GE-1, n=10 implantes) e na outra tíbia o titânio usinado (GC, n=5 implantes) ou jateado com brushita (GE-2, n=5 implantes). Os animais receberam marcadores ósseos fluorescentes, tetraciclina (14 e 21 dias), alizarina (28 e 35 dias) e calceína (42 e 49 dias) após a cirurgia de implantação. Ao final de 56 dias, a região dos implantes foi coletada e processada histologicamente para obtenção de cortes teciduais não desmineralizados. Nas imagens obtidas no microscópio confocal foi avaliado o percentual de área para cada marcador. Nos cortes corados pelo azul de toluidina foi avaliado morfologicamente a qualidade do tecido ósseo formado e a existência de interposição de tecido conjuntivo entre osso e implante, e morfometricamente determinado o percentual de contato osso-implante (BIC) e o percentual de tecido ósseo próximo à superfície do implante (BA). Os resultados mostraram que, não houve diferenças estatisticamente significantes entre machos e fêmeas quanto aos parâmetros avaliados. Com relação aos grupos, GE-1 e GC apresentaram cortical óssea remanescente íntegra e formação de um tecido ósseo maduro/lamelar na superfície dos implantes. No GE-2 ocorreu intensa reabsorção da cortical óssea pre-existente próxima ao implante e extensa formação óssea mais imatura em relação aos observados no GE-1 e GC. Essa intensa reabsorção e extensa formação óssea fez com que o percentual de área dos marcadores fluorescentes fosse em média 0,73 vezes maior no GE-2 em relação aos grupos GE-1 e GC. Com relação ao BIC não houve diferença entre os grupos, sendo em média de 47,8%, porém, o BA no grupo GC (66,2%) foi 0,33 vezes maior em relação ao GE-1(51,6%) e GE-2 (48,2%). No modelo utilizado o implante Y-TZP apresentou osseointegração similar ao titânio usinado e superior ao jateada com brushita, podendo ser considerado uma alternativa para substituir o implante titânio quando a estética esta envolvida. / The aim of this work was evaluate in vivo the osseointegration of implants produced with yttria stabilized zirconia (Y-TZP) and compare it with machined titanium implant and sandblasted surface with brushita titanium. Therefore, on the tibia of 20 rabbits males (n=10) and female (n=10) were implanted in one of the tibias the implant Y-TZP (GE-1, n=10 implants) and on the other tibia the machined titanium (GC, n=5 implants) or sandblasted surface with brushita titanium (GE-2, n=5 implants). The animals received fluorescent bone markers, tetracycline (14th and 21th days), alizarin (28th and 35th days) and calcein (42th and 49th days). At the end of 56 days, the implants regions were collected and histomorphometrically processed to obtain tissue sections not demineralized. On images obtained from confocal microscopy was evaluated the percentage of area for each bone markers. On slides stained with toluidine blue was measured morphologically the quality of formed bone tissue and the existence of interposition of connective tissue between bone and implant, and was morphometrically determined the percentage of bone-implant contact (BIC) and the percentage of bone tissue next to the implant surface (BA). The results showed that there were no statistically significant differences between male and female regarding to evaluated parameters. Concerning to the groups, GE-1 and GC exhibited wholesome remaining cortical bone and formation of mature/lamellar bone tissue on implants surface. In GE-2 ocurred intense reabsorption of preexisting cortical bone next to the implant and extensive bone formation more immature than GE-1 and GC. This intense reabsorption and extensive bone formation made the GE-2 area percentage for fluorescent markers 0.73 times higher on average when compared to GE-1 and GC. About the BIC, there were no differences between the groups, with an average of 47.8%, however, the BA on GC group (66.2%) was 0.33 higher compared to GE-1 (51.6%) and GE-2 (48.2%). In the model used, the Y-TZP implant exhibited osseointegration suchlike machined titanium and better than sandblasted surface with brushita titanium, being considered an alternative to replace the titanium implant when aesthetics is involved.
|
49 |
Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic reviewCobein, Marcus Vinicius 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
|
50 |
Avaliação da deformação gerada nos componentes intermediários de prótese fixa implanto-suportada com diferentes alturas, com a utilização de extensômetros lineares elétricos / Assessment of the deformation of the generated in different heights of abutments of mandibular implant-supported prosthesis, with the use of strain GaugesSuedam, Valdey 10 June 2005 (has links)
Em prótese total fixa implanto-suportada as diferentes alturas dos intermediários traduzem-se em diferentes braços de alavanca aos quais os implantes são submetidos levando a um efeito de deformação dos componentes que até o momento é desconhecido. O objetivo deste trabalho foi verificar a deformação gerada em diferentes alturas de componentes intermediários de prótese total fixa mandibular implanto-suportada. Para isto foi utilizado um modelo mestre de forma circular confeccionado em aço comum (Aço 1010/20) com cinco perfurações onde foram adaptadas as réplicas de fixação de 3,75mm de diâmetro, nas quais foram fixados os intermediários. O trabalho apresentou dois grupos de três corpos de prova cada, divididos de acordo com o tipo de liga das infra-estruturas(CoCr ou PdAg) e altura dos intermediários (4,0 mm, 5,5 mm e 7,0 mm), respectivamente. Foi aplicada uma força de 100N, em um ponto de referência pré-determinado na extremidade livre, a uma distância de 15mm do centro da réplica de fixação terminal e realizadas leituras das deformações geradas na mesial e na distal de cada intermediário, com o uso de extensômetros lineares elétricos. Os resultados do estudo demonstraram que o aumento da deformação captada no intermediário adjacente ao cantilever é promovido pelo aumento da altura dos intermediários e também pela utilização de uma liga de alto módulo de elasticidade. / In implant-supported prosthesis the different heights of abutments represent different lever arms to which the implants are submitted, leading to a deformation of the components that is not completely understood. The objective of this study was to assess the deformation ocurring in different heights of abutments of mandibular implant-supported fixed prosthesis. A circular master cast made of steel (Steel 1010/20) was used with five perforations containing implant replicas of 3,75mm of diameter in which the abutments were seated. The specimens were divided in two groups of three specimens each, according to the type of alloy of the framework (CoCr or PdAg) and the abutment's height (4,0 mm, 5,5 mm and 7,0 mm), respectively. A force of 100N was applied at a point 15mm distal to the center of the terminal abutment. Readings of the deformations generated on the mesial and distal aspects of the abutment were obtained with the use of strain gauges. The results of this study demonstrated that the deformation observed in the abutments adjacent to the cantilever arm is proportional to the increase of the abutment's height and elastic modulous of the alloy.
|
Page generated in 0.1761 seconds