421

Aumento da eficiência energética em uma empresa do Pólo Industrial de Manaus: um estudo de caso

Her, Chul Gu 13 February 2008 (has links)
Made available in DSpace on 2015-04-22T22:10:16Z (GMT). No. of bitstreams: 1 Chul Gu Her.pdf: 4810480 bytes, checksum: cb2ef74020e3c4689e8e51e189818011 (MD5) Previous issue date: 2008-02-13 / A busca de competitividade para a sobrevivência de uma empresa dentro de um mercado apresenta diversos fatores determinantes, com variáveis internas e externas que podem resultar em uma seleção natural das empresas, especialmente daquelas que não estiverem preparadas com flexibilidade no gerenciamento e não tiverem uma política de redução de desperdício atrelado à busca de inovações tecnológicas e campanhas de aperfeiçoamentos da sua força de trabalho. Esta seleção natural pode ocorrer com a indicação da queda dos preços de um produto devido ao avanço de fatores tecnológicos. Uma empresa precisa estar atenta a estes avanços tecnológicos e necessita otimizar o seu gerenciamento a fim de identificar a variabilidade de fatores internos e externos do mercado. Uma empresa que se instale no Pólo Industrial de Manaus - PIM - sofre dificuldades nos dias de hoje devido ao alto custo da energia elétrica e ao decréscimo das vendas motivadas pela competição interna e também externa de outros países, o que a coloca em uma situação de risco, pois, além do alto custo de consumo dos suprimentos (energia elétrica, água, gás, óleo), estes suprimentos sofrem reajustes constantes, sufocando a empresa. O presente trabalho se refere a um estudo de caso no qual se avalia a eficiência de procedimentos na implantação de modelos de tomada de decisão em uma empresa do Pólo Industrial de Manaus. Especificamente analisa os esforços empreendidos por uma empresa do ramo cinescópio, no que se refere ao aumento de eficiência energética. A empresa em estudo conseguiu melhorar a eficiência energética através de várias tomadas de decisões e outras ações que demandaram recursos internos e externos, tendo como principal indicador de resultados o custo com relação direta à quantidade de peças. Este trabalho contribuiu para a diminuição do custo de energia tornando a empresa mais competitiva, conseguindo uma margem de economia com a energia elétrica, água, ar comprimido, ar condicionado e óleo, sem nenhum investimento, conseguindo ainda um aumento de faturamento anual que vem ocorrendo com a demanda de produção
422

Avaliação da implantação de tecnologias de percepção de uso no ambiente residencial: uma proposta de metodologia. / Implementation evaluate of the use perception technologies in the residential environment: a proposed methodology.

Katia Gregio Di Santo 04 July 2013 (has links)
O trabalho visa desenvolver uma metodologia para avaliar o impacto do emprego das tecnologias de percepção de uso no ambiente residencial quanto às reduções da demanda por energia elétrica e emissões de CO2. Tais tecnologias são: eliminador de stand-by, gerenciador de energia em computadores e sensor de presença. Inicialmente são selecionadas cargas residenciais e coletados seus dados para compor um banco de dados que será utilizado nas análises. Cada carga e conjunto destas recebe a tecnologia adequada, sendo então calculado o consumo evitado e o investimento relacionado. Foram criados perfis de funcionamento das cargas (6, 8 e 10h) para reproduzir diferentes comportamentos dos usuários e cenários de utilização das cargas (A, B e C) para a análise de sensibilidade. Foram feitos estudos de caso com diferentes modelos residenciais, sendo calculados: consumo e demanda de energia evitados e redução de emissões (considerando um conjunto de residências similares). Também foi realizada a análise de viabilidade econômica da implantação, considerando o Custo Marginal de Expansão do setor elétrico (visão do investidor em infraestrutura) e as tarifas de energia elétrica (visão do consumidor). Os resultados apontam para uma contribuição relevante, em termos de eficiência energética, do emprego de tais tecnologias, representando 35 a 85 MW evitados e redução de emissões de 59 a 145 mil tCO2/ano, dependendo do tipo de modelo residencial adotado, considerando a cidade de São Paulo. A análise de viabilidade econômica por payback simples apontou os seguintes retornos de investimento: 7,2 a 15,5 anos e 2,3 a 7,4 anos para o investidor em infraestrutura e consumidor, respectivamente, dependendo do modelo residencial. Já a análise por Custo da Energia Economizada (CEE) apontou a viabilidade para o consumidor em todos os modelos residenciais, exceto o de tarifa social. Desta forma, o emprego de tais tecnologias pode contribuir de forma importante com a postergação da expansão da matriz energética, resultando em redução de investimentos em expansão e das emissões de CO2 relacionados à geração de energia elétrica, além de poder representar economia na conta de energia dos moradores. / This study aims to develop a methodology to evaluate the utilization impact of the use perception technologies in residential environment in reducing the demand for electricity and CO2 emissions. These technologies are: standby killer, power manager for computers and presence sensor. Initially, residential loads are selected and their data is collected to compose a database that will be used in the analyzes. Each load and load group receives the appropriate technology and then are calculated the avoided consumption and the acquisition investment of the technology. Loads operational profiles (6, 8 and 10h) were created to represent user behaviors and loads usage scenarios (A, B and C) were created to conduct a sensitivity analysis. Case studies were carried out with different residential models, where were calculated: avoided electricity consumption and electric energy demand and CO2 emission reduction (considering a set of similar residences). Also, it was conducted the analysis of economic implantation viability, considering the Expansion Marginal Cost of the electric sector (infrastructure investor view) and the electric energy rates (customer view). The results point out to a relevant contribution, in terms of energy efficiency, of the utilization of such technologies, representing 35 to 85 MW of avoided demand and emission reductions of 59 to 145 thousand tCO2, per year, depending on the residential model type adopted, considering Sao Paulo city region. The analysis of economic implantation viability by payback point out the following investments returns: from 7.2 to 15.5 years and from 2.3 to 7.4 years to infrastructure investor and customer, respectively, depending on the residence model. The analysis by Cost of Saved Energy point out the implementation viability for the costumer in all residential models, except the social tariff. Thus, the use of such technologies can significantly contribute to the postponement of the energetic matrix expansion, resulting in reduction of expansion investments and of CO2 related to electric energy generation, besides can represent savings in the residents energy bill.
423

GreenSDN: energy efficiency in software defined networks. / GreenSDN: eficiência energética em redes definidas por software.

Bruno Bastos Rodrigues 15 August 2016 (has links)
A significant number of protocols and capabilities have been proposed in recent years in response to the demand for reducing the amount of energy consumed by the network infrastructure. Besides rising economic issues, there is a widespread sensitivity to ecological impacts since both energy costs and electrical demands are in a upward trend. In this scenario, the development and validation of energy saving strategies are a key point of making networks more efficient. However, there is a lack of experimental environments designed specifically to emulate and to validate such energy efficiency solutions. This work proposes an environment not only supporting the development and discussion of energy-saving solutions but also management applications considering energy-saving primitives. For this purpose, the environment is built considering the implementation of energy efficiency capabilities that are representative of each network scope (interface, device, and network) in the Mininet environment taking as a basis the Software-defined Networking (SDN) paradigm. The environment proposed was evaluated with different experiments by comparing the energy savings obtained by activating these energy-efficiency capabilities. / Um significativo número de protocolos e funcionalidades foram propostos em resposta à crescente demanda de energia por infraestruturas de rede. Além de gerar problemas econômicos, existe uma preocupação quanto aos impactos ambientais uma vez que maior a demanda por eletricidade, maior o impacto ambiental para suprir esta demanda. Neste cenário, o desenvolvimento e validação de estratégias para economizar energia são um ponto chave para tornar infraestruturas de rede mais eficiente. No entanto, há uma falta de ambientes desenvolvidos especificamente para emular e validar soluções para eficiência energética. Com este propósito este trabalho propõe um ambiente capaz de suportar não apenas o desenvolvimento de soluções para tornar redes mais eficientes energeticamente, como também o desenvolvimento de aplicações de gerenciamento que baseiam-se em primitivas de economia de energia. Para este propósito, o ambiente é construído considerando a implementação de funcionalidades orientadas à eficiência energética que são representativas para cada escopo de rede (interface, dispositivo e rede) no ambiente de emulação Mininet tomando como base o paradigma de redes definidas por software. O ambiente proposto foi validade por meio de diferentes experimentos comparando a economia de energia obtida pela ativação destas funcionalidades.
424

Método para avaliação de sistema de gerenciamento de redes orientado a eficiência energética. / Method for evaluating network management systems oriented to energy efficiency.

Guilherme Carvalho Januário 12 February 2014 (has links)
Funcionalidades de eficiência energética vêm sendo integradas a protocolos e sistemas de gerenciamento de redes. Várias dessas funcionalidades afetam a rede de diferentes modos, acarretando compromissos. Podem afetar a confiabilidade e a disponibilidade da rede ao colocarem equipamentos e enlaces em modo dormente; e podem afetar o tempo de vida dos equipamentos ao alterarem seu modo de utilização. Os resultados da integração dessas funcionalidades à rede podem ser avaliados por emulação, que provê informação sobre como algum mecanismo de roteamento em particular, fruto dessa integração, agiria em diferentes condições de rede. Preparar um ambiente de experimentação que trate das interações entre diferentes funções da rede, considerando as funcionalidades de eficiência energética, traz alguns desafios. Uma combinação de emulação e implementação das principais funcionalidades de eficiência energética provê uma visão mais próxima sobre o que pode ocorrer em implantações reais de sistemas de gerenciamento energeticamente eficiente. Esta dissertação discute (i) como se avaliarem os compromissos existentes no emprego de técnicas de eficiência energética, mostrando também como o tempo de vida de equipamentos pode ser alterado e como a confiabilidade e disponibilidade da rede podem ser degradadas, e discute (ii) requisitos para o desenvolvimento de um ambiente de experimentação para avaliação de tais técnicas. O ambiente é baseado em roteadores implementados por software, para emulação de funcionalidades ainda não disponíveis, mas desejadas, de equipamentos de rede. Após a experimentação do protótipo de um sistema de gerenciamento de redes orientado por política de eficiência energética, aplicam-se os métodos de avaliação dos compromissos ocasionados por este sistema. / Energy efficiency features are being integrated in network protocols and management systems. Many of such features affect the network in different ways, thus yielding tradeoffs. They can affect the reliability and availability of the network when they put devices or links into sleep mode, and they can affect the lifetime of the devices as a result of the new operating pattern. The effects of integrating these features to the network can be assessed through emulation, which can provide insight on how a particular routing mechanism would perform in different network conditions. In addition, building an experimentation environment that is able to comprehensively account for interactions between different network functions taking into account energy efficiency features is challenging. A combination of emulation and implementation of major energy efficiency features provides a view closer to what may happen in a real deployment of energy-efficient management systems. This dissertation discusses (i) how to evaluate the tradeoffs existing between the use of energy-efficiency techniques and the lifetime of devices and with the reliability and availability of the network, and (ii) requirements for the development of a testbed to evaluate such techniques. The testbed is based on software routers, so to emulate future and desired network equipment functionalities. After experiments with the prototype of a sustainability-oriented network management system based on policies, an evaluation about the tradeoffs brought by such system to the network is performed.
425

Avaliação da aplicação do modo misto na redução da carga térmica em edifícios de escritórios nas cidades de São Paulo e Rio de Janeiro / Evaluation of mixed-mode application for thermal load reduction in office buildings at the cities of São Paulo and Rio de Janeiro

Gisele Saveriano De Benedetto 13 April 2007 (has links)
Diante das atuais questões ambientais, o uso eficiente da energia é uma premissa em todos os setores de atividades. Sabe-se que as edificações são grandes consumidores de energia e boa parcela desse consumo se dá em sistemas de condicionamento artificial. São três os principais fatores que atuam no balanço térmico e influenciam esse consumo: arquitetura, ocupação e clima. A arquitetura atua como intermediária nesse balanço térmico, podendo ajudar ou prejudicar as condições internas. Este trabalho estuda o desempenho térmico e energético dos edifícios de escritórios em São Paulo e Rio de Janeiro, cidades que apresentam condições extremas de calor durante o verão e até em outras estações do ano. O tipo de ocupação e a atividade realizada em edifícios de escritórios nos dias de hoje criam, por si sós, cargas térmicas elevadas que dificultam ainda mais a obtenção de conforto. Este trabalho parte do pressuposto de que existem soluções arquitetônicas de edifícios de escritórios na cidade de São Paulo capazes de garantir conforto térmico aos usuários durante parte do período de ocupação sem uso de condicionamento artificial, porém acreditar que é possível obter conforto apenas com sistemas passivos durante o ano todo nos atuais edifícios de escritórios das cidades de São Paulo e Rio de Janeiro é ilusão. Diante desse desafio, o sistema de modo misto de condicionamento ambiental une as vantagens do sistema ativo às do passivo, operando com sistemas naturais sempre que possível, reduzindo o consumo de energia e acionando o sistema ativo em situações fora das condições de conforto. Utilizar o sistema de modo misto não significa abrir as janelas de qualquer edifício no inverno. O edifício deve estar preparado para o sistema desde as etapas de projeto. Com base nesse pensamento, a pesquisa analisa o desempenho térmico e energético de três tipologias arquitetônicas operando com o sistema de modo misto em São Paulo e investiga o desempenho das mesmas tipologias sob as condições climáticas da cidade do Rio de Janeiro. As avaliações de desempenho térmico e energético das tipologias são feitas por meio de análises e comparações de resultados de simulações computacionais com o programa TAS (9.0.7 maio, 2005). / Considering current environmental issues, all sectors of activities are premised on the efficient use of energy. Its known that constructions are great energy consumers and part of this consumption is given by artificial conditioning systems. Therere three main factors in thermal balance that influences this consumption: architecture, occupation and climate. The architecture acts as intermediate in this thermal balance, being able to help or harm internal conditions. This research treats office building thermal and energy performance in São Paulo and Rio de Janeiro, cities with high temperatures not only during the summer but also in other seasons. Nowadays, offices occupation and activity are themselves great heat producers, what makes thermal comfort even more difficult to achieve. This project considers that there are office building design solutions able to produce thermal environmental conditions acceptable to a majority of occupants, without air-conditioning system, during part of the working period, in São Paulo. However, believing the possibility of achieving comfort conditions in actual office buildings, only with passive cooling strategies, during all year, in the cities of São Paulo and Rio de Janeiro, is an illusion. Facing this challenge, mixed mode system combines the best of air-conditioning and natural ventilation, operating with natural strategies whenever its possible, reducing energy consumption and using the air-conditioning system only when thermal environmental conditions are not acceptable. Mixed mode operation does not mean to open any building windows during the winter. The building must have been designed for the mixed mode system since its first projects. This research is based on this thought and thermal analysis and energy performance of three architectural design buildings operating with mixed mode system in São Paulo and investigates the performance of these building types under climate conditions of Rio de Janeiro city. The thermal and energy performance evaluations of the building types are based on the analysis and comparison of computer simulations results, with the software TAS (9.0.7 May, 2005).
426

Análise de sistemas híbridos em estabelecimentos assistenciais de saúde (EAS) visando o conforto térmico e redução de consumo energético / Hybrid systems analysis in healthcare establishments aiming the thermal comfort and energy consumption reduction

Ana Marta Aragão Grimm 08 October 2012 (has links)
No contexto de questões ambientais mundiais, os estabelecimentos assistenciais de saúde (EAS), devido a diversas mudanças apresentadas na fisiologia dos edifícios hospitalares nos últimos 100 anos, se inserem como grandes consumidores de energia. Tais alterações devem-se ao avanço das ciências médicas, a novas tecnologias em sistemas e equipamentos e ao crescimento populacional. O presente trabalho pretende analisar a contribuição do uso de tecnologias passivas em Estabelecimentos Assistenciais de Saúde (EAS) no que tange o desempenho térmico e energético, considerando normas específicas para este uso que exigem áreas assépticas através do uso de tecnologias ativas visando o controle da infecção hospitalar e a qualidade do ar interior. Esta configuração caracteriza para estes edifícios, sistemas híbridos com relação a tecnologias ativas e passivas. O caráter experimental da pesquisa foi realizado através de Simulação Computacional com o Software Energy Plus versão 7.0 em que foi analisado o desempenho térmico e energético de um edifício hospitalar. Inicialmente o edifício foi simulado em condições existentes e posteriormente foram realizadas diversas simulações com diferentes soluções arquitetônicas entre elas a inserção de tetoverde. / In the context of global environmental issues the Healthcare Establishments due to several changes on the physiology of hospital buildings over the past one hundred years have fallen as large energy consumers. Such changes were due to the advancement of medical science, new technologies in systems and equipments, and population growth. The present work intends to analyze the contribution of the use of passive technologies in Healthcare Establishments regarding the thermal and energetic performance considering specific standards for this use that demands aseptic areas through the use of active technologies aiming hospital infection control and indoor air quality. This configuration characterizes for these buildings hybrid systems related to active and passive technologies. The research\'s experimental character was made through Computer Simulation with the Software Energy Plus version 7.0 in which were analyzed the thermal and energetic performance of a hospital building. Initially the building was simulated in existing conditions and afterwards several simulations were made with different architectural solutions, in which was among them the insertion of a green roof.
427

Comparação de indicadores de eficiência energética e exergética em duas indústrias do setor sucroalcooleiro / Comparison of indicatives of energetic and exergetic efficiency in two industries of sugar-alcohol sector

Schirmer, Florian 27 June 2006 (has links)
Made available in DSpace on 2017-07-10T19:25:07Z (GMT). No. of bitstreams: 1 Florian Schirmer.pdf: 2016231 bytes, checksum: 57aa2561433d1c4c0448c03930721ca7 (MD5) Previous issue date: 2006-06-27 / This work has an objective to study and to compare energetic and exergetic indicatives of two sugar and alcohol sector industry. The study was realized in 2005 harvest time at both industries. It was opted in doing the experiment collecting datas from individual boilers in each industry, quantity of ground cane, properties of cane and bagasse, quantity of energy involved in process per sectors, commercialized energy with the concession of each region and characteristics of each equipment involved in the process. The data were collected from respective department data-bank and through interviews with the responsibles for each sector, being the work based on studies done by diary and monthly average from collected data. The results pointed that each analyzed industry has different indicators for each studied data. The study states that both factories need more efficient equipments. And exergetic indicators presented results next to the studies done to Vale do Rosário Factory and mentioned on this work. / Este trabalho teve como objetivo estudar e comparar indicativos energéticos e exergéticos de duas indústrias do setor sucroalcooleiro. O estudo foi realizado no período de safra 2005 em ambas as indústrias. Optou-se em se fazer o experimento utilizando-se dados das caldeiras individualmente em cada indústria, quantidade de cana moída, propriedades da cana e do bagaço, quantidade de energia envolvida no processo por setores, energia comercializada com a concessionária de cada região e características de cada equipamento envolvido no processo. Os dados foram colhidos dos bancos de dados dos respectivos departamentos e por meio de entrevistas com os responsáveis de cada setor, sendo o trabalho baseado em estudos feitos pelas médias diárias e mensais dos dados coletados. Os resultados apontaram que cada indústria analisada tem indicadores diferentes para cada dado estudado. O estudo comprova que ambas as usinas necessitam de equipamentos mais eficientes. Já os indicadores exergéticos apresentaram resultados muito próximos aos do estudo feito para a Usina Vale do Rosário e mencionados neste trabalho.
428

Energia embutida na construção de edificações no Brasil: contribuições para o desenvolvimento de políticas públicas a partir de um estudo de caso em Mato Grosso do Sul / EMBODIED ENERGY IN THE CONSTRUCTION OF BUILDINGS IN BRAZIL: CONTRIBUTIONS TO PUBLIC POLICY DEVELOPMENT BASED ON A CASE STUDY IN MATO GROSSO DO SUL.

Maria Inês Tavares de Matos Teodoro 04 December 2017 (has links)
O consumo de energia embutida nas edificações acontece ao longo do seu ciclo de vida nas atividades relacionadas com a construção e manutenção. Trata-se de um consumo de cálculo complexo uma vez que o seu valor está contabilizado em outros setores econômicos como o setor industrial de produção de materiais construção e o setor de transportes. A contribuição da energia embutida nas edificações do Brasil chega a 40% do seu ciclo de vida energético. Para além disso as necessidades de infraestrutura no país, em particular no setor residencial, deverão resultar em elevados consumos energéticos para a sua construção, contribuindo para pressionar as necessidades de expansão dos sistemas de oferta de energia. Neste contexto, o objetivo central desta pesquisa é calcular a energia embutida na construção de um condomínio residencial na cidade de Campo Grande no Estado de Mato Grosso do Sul. Para tal foi utilizada um metodologia baseada em Avaliação de Ciclo de Vida Energético (ACVE) tendo sido considerados dois cenários que diferem quanto à eficiência energética na etapa do transporte. Obteve-se um consumo de energia embutida inicial por unidade de área de 4,99 GJ/m2 para o cenário 1 e 5,52 GJ/m2 para o cenário 2, com participações de energia não renovável de 61,2% e 64,2%, respectivamente. No cenário 1 a etapa de fabricação dos materiais respondeu por 96,1% do consumo de energia embutida, o transporte contribuiu com 3,2% e a construção com 0,7%. Já no cenário 2, a participação de cada etapa foi de 86,8%, 12,6% e 0,6% respectivamente. Os resultados do estudo de caso apresentado e o panorama elaborado sobre a energia embutida nas edificações brasileiras realizado nesta tese reforçam a necessidade de incluir a energia embutida como critério de eficiência energética no desenvolvimento de políticas públicas que contribuam para reduzir o consumo de energia no setor de edificações. / The embodied energy in buildings is an energy consumption that happens throughout its life cycle in the activities related to construction and maintenance. Embodied energy calculation is a complex process since its value is accounted for in other economic sectors such as the manufacture of building materials and transportation. The contribution of embodied energy in Brazilian buildings reaches 40% of its energy consumption life cycle. In addition, infrastructure needs in the country, particularly in the residential sector, should result in high energy consumption for its construction, contributing to put pressure on the expansion needs of the energy supply system. In this context, the main objective of this research is to calculate the embodied energy in the construction of a residential condominium in the city of Campo Grande in the State of Mato Grosso do Sul. A methodology based on Life Cycle Energy Assessment (LCEA) was used considering two scenarios that differ in terms of energy efficiency at the transportation stage. Initial Embodied Energy per unit area was 4.99 GJ/m2 for scenario 1 and 5.52 GJ/m2 for scenario 2, with a non-renewable energy share of 61.2% and 64, 2%, respectively. In scenario 1, the material manufacturing stage accounted for 96.1% of the initial embodied energy value, transportation contributed with a share of 3.2% and the construction stage with 0.7%. In scenario 2, the share of each stage was 86.8%, 12.6% and 0.6%, respectively. The results of the presented case study and the elaborated panorama on the embodied energy in Brazilian buildings carried out in this thesis reinforce the need to include embodied energy as a criterion of energy efficiency in the development of public policies that contribute to reduce energy consumption in the building sector.
429

Avaliação através do desempenho térmico de edificação verticalizada em Belém-PA

VINAGRE, Natália Daniele de Lima 01 April 2013 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-07-29T16:25:43Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoAtravesSimulacao.pdf: 4321295 bytes, checksum: 857ddcf3cd7399304db433864005beb8 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-08-01T13:28:57Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoAtravesSimulacao.pdf: 4321295 bytes, checksum: 857ddcf3cd7399304db433864005beb8 (MD5) / Made available in DSpace on 2014-08-01T13:28:57Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoAtravesSimulacao.pdf: 4321295 bytes, checksum: 857ddcf3cd7399304db433864005beb8 (MD5) Previous issue date: 2013 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presente dissertação de mestrado estuda o desempenho térmico de materiais de fachada em uma edificação verticalizada na cidade de Belém – PA, Brasil. Este trabalho tem por objetivo contribuir com estudo do desempenho térmico e eficiência de materiais utilizados na envoltória das edificações residenciais verticalizadas, entre os elementos opacos, foram selecionados dois tipos de materiais, bastante utilizados atualmente na construção civil, a pintura e revestimento cerâmico. Também estuda-se a influência da altura da edificação sobre seu desempenho térmico e eficiência energética. O estudo foi desenvolvido com o uso de modelagem em código computacional no programa EnergyPlus que permite avaliar o desempenho térmico da edificação, a influência da altura na eficiência energética da mesma. Compara-se o desempenho térmico dos dois materiais selecionados, verificou-se que o prédio com revestimento cerâmico apresentou a temperatura interna média anual de 0,42 º C acima da temperatura referente ao prédio pintado, portanto com menor desempenho térmico. A influência da altura do pavimento não produziu uma variação significativa na temperatura interna, pois com seu acréscimo, ocorreu pequena diminuição da temperatura interna, com gradiente térmico da ordem de -0,07ºC /m em decorrência da velocidade do vento que é maior quando mais alto é o pavimento. Considera-se também para este estudo a ventilação natural como estratégia passiva para a edificação em estudo, que segundo a análise da Carta Bioclimática de Givoni contribuiria positivamente para a condição de temperatura interna e umidade do ar, e consequentemente do usuário. / This dissertation studies the thermal performance of materials in a vertical facade building in the city of Belém - PA, Brazil. This work aims to contribute to the study of the thermal performance and efficiency of materials used in residential buildings of the vertical envelopment, between opaque elements, two types of materials currently very used in construction were selected, painting and ceramic coating. It also studies the influence of the height of the building on its thermal performance and energy efficiency. The study was conducted with the use of computational modeling in EnergyPlus code that evaluates the thermal performance of the building, the influence of the height at the same energy efficiency. Compares the thermal performance of the two selected materials, it was found that the ceramic coating presented building with the average internal temperature of 0.42 ° C above the temperature at the building painted, hence less thermal performance. The influence of the height of the floor did not produce a significant variation in internal temperature, because its increase, small decrease occurred in the internal temperature with thermal gradient of about -0.07 º C / m due to the wind speed is greater when more higher the pavement. It is also considered for this study as passive natural ventilation strategy for the building under study, according to the analysis of Bioclimatic chart Givoni contribute positively to the condition of the internal temperature and humidity, and consequently the user.
430

Caracterização de um gaseificador do tipo downdraft

ALVES, Charles Denys da Luz January 2010 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-04-07T16:42:52Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_CaracterizacaoGaseificadorTipo.pdf: 600936 bytes, checksum: 0de9c466832c23a25a0f22bd65d49fa6 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-06-16T16:39:03Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_CaracterizacaoGaseificadorTipo.pdf: 600936 bytes, checksum: 0de9c466832c23a25a0f22bd65d49fa6 (MD5) / Made available in DSpace on 2014-06-16T16:39:03Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_CaracterizacaoGaseificadorTipo.pdf: 600936 bytes, checksum: 0de9c466832c23a25a0f22bd65d49fa6 (MD5) Previous issue date: 2010 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / A gaseificação é uma conversão termoquímica da biomassa em gás combustível, que pode ser usado como combustível em motores de combustão interna ou como gás de síntese para a indústria química. Para checar o desempenho de um gaseificador temos de quantificar a energia contida no gás produzido e a quantidade de carbono convertido por meio dos cálculos de eficiência energética e de conversão de carbono através dos dados obtidos experimentalmente. A eficiência energética é uma relação entre os fluxos de gás e biomassa e de suas respectivas quantidades de energia, no mesmo sentido, a conversão de carbono é a quantidade de compostos carbonáceos presentes no gás convertido a partir da quantidade de carbono presente na composição da biomassa. O presente documento avalia a eficiência energética e de carbono na conversão de um protótipo de um gaseificador indiano do tipo downdraft produzido por uma empresa local (Floragás). Os parâmetros nominais do gaseificador são: capacidade de produção de gás de 45 kWt, consumo de biomassa (caroço de açaí) de 15 kg/h. As dimensões do gaseificador são: DI 150 mm e altura de 2000 mm). A eficiência energética e a taxa de conversão de carbono foram quantificados, a queda de pressão devido ao leito do reator e a temperatura dos gases também foram medidos na saída do reator e também, a concentração de alcatrão, partículas e gases não condensáveis (CO, CO2, CH4, SO2, N2 e NOx) nos gases de combustão após a sistema de limpeza. / The gasification is a thermo-chemical conversion of biomass in fuel gas which can be used as a fuel in internal combustion engines or as a syngas for chemical industry. To quantify the performance of a gasifier we must quantify the energy contained in the gas produced and relate to the amount of energy contained in the biomass that feeds the gasifier, Energy Efficiency, and even with regard to levels of carbon converted from biomass into the gas produced, Carbon Conversion. This paper assesses the energy efficiency and carbon conversion in a prototype of an Indian downdraft gasifier type produced by a local company (Floragás). The gasifier nominal parameters are: gas production capacity of 45 kWt, açaí seeds consumption of 15 kg/h. The gasifier reactor dimensions are ID 150 mm and height in 2000 mm). Its energy efficiency and rate of carbon conversion were quantified, the drop in pressure due to the reactor bed and the gas temperature were also measured at the reactor exit and quantified the concentration of tar, particulate and not condensable gases (CO, CO2, CH4, SO2, N2 and NOx) in the flue gas after cleaning system.