• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 483
  • 30
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 533
  • 533
  • 323
  • 307
  • 186
  • 85
  • 73
  • 70
  • 65
  • 58
  • 55
  • 47
  • 42
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Avaliação do rendimento luminoso e a vida útil das lâmpadas fluorescentes compactas em regime de uso intermitente. / Evaluation of luminous performance and lifetime of compact fluorescent lamps in the regime of intermittent use.

Emigdio Concepcion Espínola Velázquez 09 November 2016 (has links)
Esta tese tem como principal objetivo medir o desempenho das lâmpadas fluorescentes compactas em regime de uso intermitente instaladas em residências. Utiliza a Norma NBR 14539 e a PORTARIA 489/2010 como referência, para a comparação dos valores obtidos nas medições de campo com as medições do laboratório. A metodologia aplicada tem a finalidade de medir o desempenho em um ambiente real e muito mais agressivo que o laboratório. Foram instaladas 95lâmpadas de três marcas diferentes e dividida em três grupos, previamente as lâmpadas foram sazonadas ou \"envelhecidas\" por 100 horas e posteriormente instaladas nas residências. Neste estágio, as medições de campo foram realizadas durante dezoito meses em quatro oportunidades, (a primeira como referência), posteriormente foram retiradas e levadas novamente ao laboratório para medir a depreciação do fluxo luminoso. As variáveis medidas foram: Fluxo luminoso, iluminância, tensão, temperatura, umidade relativa e quantidade de chaveamento para o acendimento das lâmpadas. Para ter uma visão mais ampla, os resultados, foram comparados à norma brasileira com as normas internacionais em relação aos requisitos de desempenho das lâmpadas fluorescentes compactas. Também foi feito um questionário com os consumidores que participaram desta pesquisa, para verificar o conhecimento ou a \"cultura energética\" relacionada com a forma de uso da iluminação, manutenção dos circuitos, idade, gênero, situação laboral, classe social, consumo, escolha de lâmpadas na hora da compra, uso da iluminação natural, utilização de tintas claras no interior das residências. Todo procedimento de medições foi realizado no Laboratório de Fotometria do Instituto de Energia e Ambiente-IEE da Universidade de São Paulo/USP. / This thesis aims to verify the performance of compact fluorescent lamps (CFLs) that are installed in residences in intermittent use regime. It uses NBR 14539 and Ordinance 489/2010 as a reference for comparing the values measured in the field in the laboratory measurements. The methodology used to verify the performance in a real environment is more aggressive than the laboratory\'s. 95 lamps of three different brands were installed, which were divided into three groups, The lamps were previously seasoned or \"aged\" for 100 hours and then installed in residences. At this stage, the field measurements were conducted for eighteen months, four times until reaching 2,000 hours of use. Later, they were removed and taken back to the laboratory to check the depreciation. Measured variables were: Iluminância, voltage, temperature, relative humidity and the amount of switching to lighting the lamps. To consolidate, Brazilian standards were compared to international standards in order to verify if there are differences or coinciding points. A questionnaire was also filled in by consumers who participated in this research to verify the knowledge or \"energy culture\" related to the proper use of lighting, maintenance of circuits, age, gender, employment status, social class, consumption, choice of lamps at the time of purchase, use of natural lighting, use of clear paint inside the residences. Finally, it is worth mentioning that the entire measurement procedure was performed in the photometry laboratory of the Institute of Energy and Environment-IEE, University of São Paulo/USP.
432

Consumo desagregado de energia: técnicas de monitoramento não intrusivo. / Disaggregated energy consumption: nonintrusive load monitoring techniques.

Eduardo Kanashiro 19 November 2015 (has links)
As Ações de Eficiência Energética encontram grandes barreiras para sua implantação. Um dos motivos pode estar na falta de conhecimento do tomador de decisão que, para evitar o custo inicial mais elevado de um equipamento eficiente, opta por instalar um equipamento mais barato, mas que consequentemente consome mais energia e aumenta os dispêndios com a eletricidade. Os sistemas de gestão de energia visam demonstrar a origem das despesas relacionadas ao consumo de energia elétrica, conscientizando os usuários acerca de tais custos. Muitos usuários não enxergam a possibilidade de economia de energia e de dinheiro, ao investir em equipamentos mais eficientes. Muitos consideram as faturas de energia como despesas fixas, logo, sem exigência de acompanhamento. Fato não compatível com os dias atuais. Ao identificar o consumo desagregado de energia da instalação, os usuários poderão avaliar os impactos de suas atividades em relação ao consumo de energia, assim com seu custo nas faturas de energia. A medição direta dos equipamentos reproduz o valor mais preciso do consumo desagregado. Entretanto, para muitas instalações esta prática é inviável, pois seus circuitos são compartilhados por diversos tipos de equipamentos e os custos de aquisição, implantação e leitura dos medidores podem se tornar proibitivos. É possível obter o valor do consumo desagregado por inspeção da instalação, que consiste no levantamento das características elétricas dos equipamentos, suas respectivas potências e períodos de utilização. Esse método, no entanto não é tão preciso na análise do consumo desagregado, pois envolve uma série de estimativas acerca da utilização dos equipamentos, que nem sempre são acertadas. Visando contornar estas situações, as técnicas de monitoramento não intrusivo de carga passaram a buscar na curva de carga as assinaturas elétricas dos equipamentos, para identificar seus períodos de funcionamento e assim obter o consumo desagregado. / The energy efficiency programs face huge difficulties to be deployed. The reason may be the lack of knowledge about total costs in acquires less efficient devices, which is cheaper, though the increases in energy bills eliminate this initial economy. Thereby, the Energy Management Systems aims to demonstrate the relation between the user\"s behavior and the electric power consumption. Many managers consider the electric bill as a fixed cost, without require tracking its origin. This means waste of energy and money. Analyzing the facility by sectors may improve the understanding about the costs in electricity and the knowledge about the disaggregated energy consumption, though is not always an easy issue to be obtained. Monitoring each equipment provides the exactly amount of energy is used in that system. However the costs of acquirement, implementation and monitoring these meters may become prohibitively. This way, the researches about nonintrusive load monitoring aim to demonstrate where the energy is being used and how it can be minimized.
433

Comparação de indicadores de eficiência energética e exergética em duas indústrias do setor sucroalcooleiro / Comparison of indicatives of energetic and exergetic efficiency in two industries of sugar-alcohol sector

Schirmer, Florian 27 June 2006 (has links)
Made available in DSpace on 2017-05-12T14:48:29Z (GMT). No. of bitstreams: 1 Florian Schirmer.pdf: 2016231 bytes, checksum: 57aa2561433d1c4c0448c03930721ca7 (MD5) Previous issue date: 2006-06-27 / This work has an objective to study and to compare energetic and exergetic indicatives of two sugar and alcohol sector industry. The study was realized in 2005 harvest time at both industries. It was opted in doing the experiment collecting datas from individual boilers in each industry, quantity of ground cane, properties of cane and bagasse, quantity of energy involved in process per sectors, commercialized energy with the concession of each region and characteristics of each equipment involved in the process. The data were collected from respective department data-bank and through interviews with the responsibles for each sector, being the work based on studies done by diary and monthly average from collected data. The results pointed that each analyzed industry has different indicators for each studied data. The study states that both factories need more efficient equipments. And exergetic indicators presented results next to the studies done to Vale do Rosário Factory and mentioned on this work. / Este trabalho teve como objetivo estudar e comparar indicativos energéticos e exergéticos de duas indústrias do setor sucroalcooleiro. O estudo foi realizado no período de safra 2005 em ambas as indústrias. Optou-se em se fazer o experimento utilizando-se dados das caldeiras individualmente em cada indústria, quantidade de cana moída, propriedades da cana e do bagaço, quantidade de energia envolvida no processo por setores, energia comercializada com a concessionária de cada região e características de cada equipamento envolvido no processo. Os dados foram colhidos dos bancos de dados dos respectivos departamentos e por meio de entrevistas com os responsáveis de cada setor, sendo o trabalho baseado em estudos feitos pelas médias diárias e mensais dos dados coletados. Os resultados apontaram que cada indústria analisada tem indicadores diferentes para cada dado estudado. O estudo comprova que ambas as usinas necessitam de equipamentos mais eficientes. Já os indicadores exergéticos apresentaram resultados muito próximos aos do estudo feito para a Usina Vale do Rosário e mencionados neste trabalho.
434

Desempenho de conjunto motor-gerador utilizando biocombustíveis sob cargas variadas / Performance of engine-generator set using biofuels under varied loads

Rigotte, Marcio Roberto 14 February 2014 (has links)
Made available in DSpace on 2017-07-10T15:14:29Z (GMT). No. of bitstreams: 1 DissertacaoMarcioRRigotte.pdf: 1614115 bytes, checksum: 34d26d4df31cfcd99ebf450c783bee96 (MD5) Previous issue date: 2014-02-14 / The rising demand for energy, coupled with its high cost and the search for sustainability propitiated in recent years an increase in demand for renewable biofuels, including biodiesel. Although Brazil, and specifically Paraná, present agricultural vocation, with diversity of raw materials for biodiesel production, it remains tied to demand compulsory. This work aimed to evaluate the energetic performance of an engine-generator set using diesel oil and biodiesel of different feedstocks. The experiment was conducted in the Experimental Nucleus for Agricultural Engineering (NEEA), State University of West Paraná (UNIOESTE), located in Cascavel - Paraná, using entirely randomized design. The treatments were diesel oil, and three different types of biodiesel (crambe, soybean and waste frying oil) being used pure biodiesel (B100) and the binary blends B10, B20 and B50. The resistive loads used were 1, 2, 3, 4 and 5 kW for each type of fuel, a total of five replications. Among other observations, we evaluated the heating value, specific fuel consumption (CE) and energy efficiency (EE). The best CE was diesel with 0,349 Kg KW h-1 in the load 5 KW, followed by BC20-2 with 0,524 Kg kW h-1 and BC50-3 with 0,433 Kg kW h-1. Biodiesel has the CE nearest of the diesel with increasing resistive load, indicating that its use in operation closest the rated capacity is more efficient. Among the types of biodiesel, the crambe oil showed lower CE, with some values without significant differences (Tukey 5%) of the diesel CE, as BC20-4 with 0,383 Kg kW h-1 and BC10-5 with 0,367 Kg KW h-1. The best EE were DI-5 25,6%, BC100-5 25,5%, BC50-5 25,0%, BS100-5 24,8% and BORF100-5 24,6%. Pure biodiesel (B100) tends to show best EE that the binary blends used. The BC100 showed EE of 9,9 17,8, 21,8, 24,3 and 25,5% respectively for resistive load of 1, 2, 3, 4 and 50 KW. In the range of biodiesel evaluated, crambe oil obtained EE closer to diesel, and the BC100 exceeded diesel EE to the loads 2, 3 and 4 / A crescente demanda por energia, associada a seus elevados custos e a busca por sustentabilidade propiciaram nos últimos anos um aumento na procura por biocombustíveis renováveis, dentre eles o biodiesel. Apesar do Brasil, e especificamente o Paraná, apresentarem vocação agrícola, com diversidade de matérias-primas para obtenção de biodiesel, esta permanece atrelada a demanda compulsória. Este trabalho buscou avaliar o desempenho energético de um conjunto motor-gerador utilizando diesel de petróleo e biodiesel de diferentes matérias primas. O experimento foi conduzido no Núcleo Experimental em Engenharia Agrícola (NEEA), da Universidade Estadual do Oeste do Paraná (UNIOESTE), Cascavel Paraná, utilizando delineamento experimental inteiramente casualizado. Os tratamentos utilizados foram o diesel de petróleo, e três diferentes tipos de biodiesel (crambe, soja e óleo residual de fritura), sendo o biodiesel utilizado puro (B100) e nas misturas binárias B10, B20 e B50. As cargas resistivas utilizadas foram de 1, 2, 3, 4 e 5 KW para cada tipo de combustível, com total de cinco repetições. Entre outras observações, foi avaliado o poder calorífico, o consumo específico (CE) e a eficiência energética (EE). O melhor CE foi o diesel com 0,349 Kg KW h-1 na carga 5 KW, seguido por BC20-2 com 0,524 Kg KW h-1 e o BC50-3 com 0,433 Kg KW h-1. O biodiesel apresenta CE mais próximo do diesel com o aumento da carga resistiva, indicando que sua utilização em operações mais próxima da capacidade nominal é mais eficiente. Dentre os tipos de biodiesel, o de óleo de crambe apresentou menor CE, com alguns valores sem diferenças significativas (Tukey 5%) do CE do diesel, como o BC20-4 com 0,383 Kg KW h-1 e o BC10-5 com 0,367 Kg KW h-1. As melhores EE foram DI-5 25,6%, BC100-5 25,5%, BC50-5 25,0%, BS100-5 24,8% e BORF100-5 24,6%. O biodiesel puro (B100) tende a apresentar melhor EE que as misturas binárias utilizadas. O BC100 apresentou EE de 9,9 17,8 21,8 24,3 e 25,5% respectivamente para as cargas resistivas de 1, 2, 3, 4 e 5 KW. Na gama de biocombustíveis avaliados, o de óleo de crambe obteve EE mais próxima ao do diesel, sendo que BC100 superou EE do diesel nas cargas 2, 3 e 4.
435

Mapeamento de oportunidades de negócios a partir de laboratórios de pesquisa e desenvolvimento: estudo de caso CEAMAZON

PEREIRA, Márcio Roberto do Carmo 28 November 2014 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2015-04-24T14:44:19Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_MapeamentoOportunidadesNegocios.pdf: 124259573 bytes, checksum: 4ac90a4f648551c861f08a38d3ce4f77 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-04-24T15:12:56Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_MapeamentoOportunidadesNegocios.pdf: 124259573 bytes, checksum: 4ac90a4f648551c861f08a38d3ce4f77 (MD5) / Made available in DSpace on 2015-04-24T15:12:56Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_MapeamentoOportunidadesNegocios.pdf: 124259573 bytes, checksum: 4ac90a4f648551c861f08a38d3ce4f77 (MD5) Previous issue date: 2014 / Este trabalho volta-se a área de inovação e a tecnologia como fator de diferenciação e geração de negócios de base tecnológica a partir de projetos de pesquisa e desenvolvimento do Centro de Excelência em Eficiência Energética na Amazônia – CEAMAZON, visando identificar e classificar o potencial de empreendimentos oriundos dos projetos dos laboratórios de P&D em energia deste centro. Utilizou-se a metodologia do Radar de negócios em tecnologia e inovação (RANTI) para levantar e gerar um portifólio de negócios em energia, e o potencial de inovação do CEAMAZON para que a sociedade faça uso do conhecimento gerado a partir desse centro de pesquisa para a criação de empresas e negócios por empreendedores, investidores e/ou empresários, a fim de gerar empregos, mais tecnologia e multiplicar a capacidade do CEAMAZON de criar mais projetos de P&D com interface com o mercado. / This is work focuses on innovation and technology as a differentiating factor and generation of Business Technology Based Projects from the Research and Development Center of Excellence in Energy Efficiency in the Amazon - CEAMAZON, to identify and rank potential projects arising from Projects R&D Labs in this energy center. It is used the methodology of radar of technology and business innovation (Ranti) togather and to generate a portfolio of businesses in energy, and the potential for Innovation of CEAMAZON for society to make use of the knowledge generated from this research center, the creation of companies and businesses by entrepreneurs, investors and / or entrepreneurs in order to create jobs, more technology and multiply the capacity of CEAMAZON to create more projects with R&D interface with the market.
436

Eficiência energética em redes sustentáveis: uma avaliação baseada em redes small cells e backhaul

LOPES, Albert Richard Moraes 13 March 2015 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-26T12:51:36Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EficienciaEnergeticaRedes.pdf: 2582901 bytes, checksum: 3c2e3a777d7d89dbe7945256b638bdcb (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-26T13:06:49Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EficienciaEnergeticaRedes.pdf: 2582901 bytes, checksum: 3c2e3a777d7d89dbe7945256b638bdcb (MD5) / Made available in DSpace on 2017-01-26T13:06:49Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EficienciaEnergeticaRedes.pdf: 2582901 bytes, checksum: 3c2e3a777d7d89dbe7945256b638bdcb (MD5) Previous issue date: 2015-03-13 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / A utilização de small cells em redes móveis heterogêneas (seja 3G, 4G e futuramente 5G) para tráfego indoor tem sido considerada como a melhor solução para suprir o crescimento do tráfego móvel, devido reduzir o consumo de energia da rede e por fornecer alta capacidade. Por outro lado, o aumento da quantidade de small cells implantadas implica na ampliação da rede backhaul, que aumenta o consumo de energia na rede e ameaça os ganhos das small cells nesse tópico. Além disso, dependendo da escolha do tipo backhaul o consumo de energia na rede heterogênea pode elevar consideravelmente. Neste contexto, este trabalho visa fornecer uma metodologia para avaliar e identificar possíveis gargalos de consumo de energia na rede móvel, considerando tanto a parte wireless quanto a estrutura backhaul. A metodologia considera a demanda de tráfego gerado na cidade, cenário para implantação e operação de redes heterogêneas (small cells) e dimensionamento do backhaul por segmento (Cell Site, Hub Site e Central Office). Adotando esta metodologia, o estudo deste trabalho avalia e compara três tipos de arquitetura backhaul para redes internas baseadas em Femtocell convencional ou Femtocell Wireless over Cable (FemtoWoC): Fiber-to-the- Building, Fiber-to-the-Curb e Fiber-to-the-Home. Constatou-se que o principal gargalo energético do backhaul se encontra no segmento responsável por agregar o tráfego das small cells (Cell Site). Contudo, empregando arquiteturas e equipamentos mais eficientes, como FemtoWoC, no segmento Cell Site pode-se reduzir significativamente o consumo total de energia no backhaul, principalmente em arquiteturas baseada em cobre na última milha. / The use of small cells in heterogeneous networks (either 3G, 4G and 5G future) for indoor traffic has been regarded as the best solution to meet the growth of mobile traffic due to reduce network power consumption and to guarantee the high capacities. Moreover, increasing the amount of small cell deployment implies in the expansion of the backhaul network, which causes an increase on the network power consumption, and threatens the small cells gains in terms of energy. Furthermore, the energy consumption in heterogeneous network can increase considerably depending on the choice of the type backhauling. Considering this background, this work aims to provide a methodology to assess and identify possible energy consumption bottlenecks in the mobile network, considering both the wireless part as the backhaul infrastructure. The methodology considers the demand of traffic generated in the city, scenario to implementation and operation of heterogeneous networks (small cells), and dimensioning backhaul by segment (Cell Site, Hub Site e Central Office). Adopting this methodology, the study evaluates and compares three types of backhaul architecture for conventional Femtocell or Femtocell Wireless over Cable (FemtoWoC) network: Fiber-to-the-Building, Fiber-to-the-Curb e Fiber-to-the-Home. It was found that the main bottleneck in the backhaul architecture is the segment that is responsible for aggregating traffic from small cells (Cell Site). However, adopt architectures and equipment with high energy efficiency, as FemtoWoC, in the segment bottleneck reduce significantly the total power consumption in the backhaul, mainly architectures based on copper in the last mile.
437

Análise de certificação de edificação pública de ensino e pesquisa visando nível A pelo RTQ-C através de ações de eficiência energética e análise econômica

RIBEIRO, Ricardo Bastos Piqueira 07 July 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-27T15:18:13Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseCertificacaoEdificacao.pdf: 3409495 bytes, checksum: b1d56892bffe0d6964bc1e8c788157c1 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-30T11:35:50Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseCertificacaoEdificacao.pdf: 3409495 bytes, checksum: b1d56892bffe0d6964bc1e8c788157c1 (MD5) / Made available in DSpace on 2017-01-30T11:35:50Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseCertificacaoEdificacao.pdf: 3409495 bytes, checksum: b1d56892bffe0d6964bc1e8c788157c1 (MD5) Previous issue date: 2016-07-07 / Esta dissertação apresenta a análise de eficiência energética predial feita no edifício do Ceamazon, laboratório de pesquisas vinculado à Universidade Federal do Pará. Para este estudo foi utilizada a metodologia prescritiva do Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Comerciais, de Serviços e Públicas – RTQ-C. A análise energética do RTQ-C envolve três parâmetros distintos: a envoltória da edificação, o sistema de iluminação artificial e o sistema de condicionamento de ar. O estudo dos dados de cada um destes sistemas fornece material para os cálculos necessários no método, que resultarão em um equivalente numérico para cada um, representando a eficiência de cada sistema. A análise desta dissertação foi efetuada principalmente nos sistemas de iluminação artificial e condicionamento de ar, visto que uma análise prévia dos dados de envoltória do prédio já havia coletado bons resultados. O objetivo primário da dissertação foi de enquadrar a edificação em questão no nível A de eficiência energética proposto pelo regulamento. Desta forma, foram feitas as adequações necessárias ao projeto do ponto de vista energético, especificamente nos sistemas de iluminação e refrigeração artificial, visando tanto a classificação máxima de acordo com o RTQ-C como também a economia de energia e consequentemente, a redução de custos. Assim sendo, serão apresentadas também propostas de inclusão de alternativas energéticas para o edifício, visando uma eficiência energética ainda maior, bem como análises de viabilidade econômica e simulações energéticas das alterações propostas ao projeto da edificação, através dos softwares RetScreen e EnergyPlus. / This dissertation presents the analysis of energy efficiency of the Ceamazon building, a research laboratory bounded to the Federal University of Pará. For this study it was utilized the prescriptive method of the “Regulamento Técnico da Qualidade para o Nível de Eficiência Energética de Edificações Comerciais, de Serviços e Públicas – RTQ-C”. RTQ-C’s energy analysis involves three distinct parameters: the building envelope, the artificial illumination system and the air-conditioning system. The study of the characteristics of each one of these systems provides material for the necessary calculations of the method, which will result in a numeric equivalent for each one, representing the efficiency of each system. This dissertation’s analysis was done mainly at the artificial illumination system and the air-conditioning system, since one previous analysis of the building’s envelope had already collected good results. The primary goal of this dissertation was to fit the building studied in the level A of energy efficiency proposed by the regulation. Thus, adjustments were made to the project from the energetic point of view, specifically on the artificial illumination and air-conditioning systems, aiming not only the maximum classification according to RTQ-C but also energy savings and the consequent reduction of costs. Therefore, proposals of inclusion of energetic alternatives to the building will also be presented, aiming at a higher energy efficiency, as well as economic viability analysis and energetic simulations of the alterations proposed to the building project, utilizing the softwares RetScreen and EnergyPlus.
438

Desenvolvimento de modelo de sistema de informações geográficas para avaliação da eficiência hidroenergética em sistemas de abastecimento de água / Geographic information system model development for evaluate thehydro-energyefficiency of water supply systems

SANTOS, Aline Christian Pimentel Almeida 29 October 2015 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-02-03T11:52:34Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoModeloSistemas.pdf: 11151369 bytes, checksum: be86db933688edc354add13e97611b70 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-02-07T16:34:32Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoModeloSistemas.pdf: 11151369 bytes, checksum: be86db933688edc354add13e97611b70 (MD5) / Made available in DSpace on 2017-02-07T16:34:32Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoModeloSistemas.pdf: 11151369 bytes, checksum: be86db933688edc354add13e97611b70 (MD5) Previous issue date: 2015-10-29 / Desenvolvimento de metodologia para a avaliação do desempenho hidroenergético de Sistemas de Abastecimento de Água (SAA) utilizando modelo de Sistema de Informações Geográficas (SIG) para auxiliar na tomada de decisão na operação de SAAs. O modelo desenvolvido em plataforma SIG possibilita o registro, a sistematização e a espacialização dos dados hidroenergéticos, a fim de evitar gastos excessivos com a energia elétrica agregada ao volume de água disponibilizado para consumo. Na 1ª Etapa foram identificados os parâmetros hidroenergéticos utilizados nos atuais métodos de gerenciamento de SAA e, em seguida, definidos os dados e indicadores para a representação espacial no modelo do desempenho hidroenergético por setor e por unidade de abastecimento de água. Na 2ª Etapa foi desenvolvido o modelo de gestão em SIG por meio da IDE Delphi XE5 e da plataforma TatukGis, em três fases: Construção do banco de dados geográfico (Fase 1); Construção do módulo SIG (Fase 2) e Construção do módulo hidroenergético (Fase 3). A última Etapa (3ª Etapa) foi destinada a avaliação da funcionalidade do modelo desenvolvido, sendo simulado o funcionamento do SAA Bolonha, da Região Metropolitana de Belém, Pará, Brasil, o que permitiu a espacialização dos dados e indicadores para identificação dos setores com melhor e com pior desempenho hidroenergético. A ferramenta de construção de mapas de graduação de cores mostrou-se eficiente, permitindo a rápida identificação do melhor resultado do índice de consumo de energia elétrica no setor 9 da Zona Central (0,62 KWh/m³), bem como do pior índice de perda total no setor 7 da Zona Central (54,29%). Além da ferramenta para sinalização de alerta para os indicadores acima da meta estabelecida pelo usuário, que possibilitou a identificação do setor 7 com o pior índice de consumo de energia elétrica (0,85 KWh/m³). Com o trabalho foi constatado que o modelo SIGHE2A é uma ferramenta que permite e agiliza a avaliação do desempenho hidroenergético de SAA, especialmente por facilitar a identificação do problema e a tomada de decisão. / Development of methodology for evaluating the performance of hydro-energy Water Supply Systems (WSS) using System Model of Geographical Information (GIS) to assist in decision-making in the SAAs operation. The model developed in GIS platform enables registration, systematization and the spatial distribution of hydro data in order to avoid excessive spending on electricity aggregate the volume of water available for consumption. In Stage 1 the hydro-energy parameters were identified WSSs used in current management methods and then set the data and indicators for the spatial representation in the model of the hydro-energy performance by sector and water supply unit. In the 2nd stage was developed the management model in GIS through Delphi IDE XE5 and TatukGIS platform in three phases: geographic database construction (Phase 1); Construction of GIS module (Phase 2) and construction of hydro-energy module (Phase 3). The last step (Step 3) was submitted to evaluation of the model developed functionality, which simulated the operation of the WSS Bolonha, the Metropolitan Region of Belém, Pará, Brazil, which allowed the spatial data and indicators to identify the sectors with best and hydro-energy worst performance. The color grading maps building tool was efficient, allowing quick identification of the best result of the electricity consumption index in sector 9 of the Central Zone (0.62 KWh / m³) and the worst index total loss in sector 7 of the Central Zone (54.29%). In addition to the warning signs for tool for the indicators above the target set by the user, which enabled the identification of sector 7 with the worst energy consumption index (0.85 KWh / m³). With the work it was found that the SIGHE2A model is a tool that enables and streamlines the evaluation of the hydro-Energy performance WSS, especially to facilitate problem identification and decision making.
439

Desenvolvimento e aplicação de metodologia para avaliação de desempenho hidroenergético de sistemas de abastecimento de água / Development of methodology and implementing for assessing hydro-energetic performance in water supply systems

REGO, Augusto da Gama 19 February 2016 (has links)
Submitted by Nathalya Silva (nathyjf033@gmail.com) on 2017-04-24T19:48:15Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoMetodologiaAvaliacao.pdf: 16688032 bytes, checksum: 8a6e2d511a2ce435deaf0be98e401872 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-04-25T21:21:46Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoMetodologiaAvaliacao.pdf: 16688032 bytes, checksum: 8a6e2d511a2ce435deaf0be98e401872 (MD5) / Made available in DSpace on 2017-04-25T21:21:46Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DesenvolvimentoMetodologiaAvaliacao.pdf: 16688032 bytes, checksum: 8a6e2d511a2ce435deaf0be98e401872 (MD5) Previous issue date: 2016-02-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A Tese de Doutorado teve por objetivo o desenvolvimento de metodologia e sua implementação em software para avaliação de desempenho hidroenergético de sistemas de abastecimento de água (SAA), bem como aplicação em sistema de escala real. A pesquisa foi executada em duas etapas: 1) foi modelado todo o processo de avaliação de desempenho hidroenergético, foram estabelecidas formulações para cálculo de perdas hidroenergéticas e implementada metodologia em software; 2) foi realizada a aplicação da metodologia em SAA de escala real, que necessitou de monitoramento de grandezas hidroenergéticas e de simulação computacional do mesmo SAA no Epanet 2.0. Os resultados da primeira etapa consistiram na definição de perdas hidroenergéticas, na conceituação de desempenho hidroenergético, na metodologia proposta (sequenciamento de ações e inerentes formulações matemáticas) para o cálculo de perdas hidroenergéticas e para avaliação de desempenho hidroenergético de SAA, na implementação da metodologia em software (batizado de SADHE2A) e no teste da metodologia com sucesso em SAA com dados sintéticos. Os resultados da segunda etapa foram consequência da aplicação da metodologia, com uso do SADHE2A – versão Beta, no SAA Guanabara (localizado na cidade de Ananindeua, Pará, Brasil), na qual foram verificadas perdas globais de água de 55,42%/m e perdas globais de energia elétrica consumida de 58,31% (ambos os desempenhos classificados como “ruim”) que ocasionaram impacto financeiro de -17.981,77 R$/mês (57,61% de toda a despesa com consumo de energia elétrica no SAA, desde a captação de água bruta até a entrega de água tratada ao consumidor). Por fim, a metodologia desenvolvida atendeu as expectativas da pesquisa para calcular as perdas de água e de energia elétrica consumida e avaliar o desempenho hidroenergético de SAA, com elevada potencialidade de uso no Brasil e no exterior. / This doctoral thesis aims developing a methodology and implementing it on software in order to evaluate a water supply system (WSS) hydro-energetic performance, as well as applying it on a real scale WSS. This paper was carried out in two stages: 1) modeling the hydro-energetic performance evaluation process, establishing of formulations to calculate hydro-energetic losses and implementing methodology on software; 2) applying the methodology at a real scale WSS, which required monitoring of hydraulic and electrical quantities and simulating this WSS at Epanet 2.0. The first stage results consisted at defined hydro-energetic losses and conceptualize hydro-energetic performance on the proposed methodology, which consists sequences of actions and mathematical formulation to calculate hydro-energetic losses at the WSS, as well as to evaluate WSS hydro-energetic performance and, finally, at methodology implementation in a software using Visual Basic for Applications (named as SADHE2A) and successfully tested at the WSS with synthetic data. The second stage results are related to methodology application at WSS of Guanabara (located at Ananindeua city, Pará, Brazil), using SADHE2A – versão Beta, in which were identified water global losses of 55.42% and electrical energy global losses of 58.31% (both classified as “bad” by the methodology), resulting in an economical deficit of 17,981.77 R$/month. This value is equivalent to 57.61% of electrical energy costs, since raw water pumping to the final water costumer. Finally, the methodology developed has met the research expectations to calculate the water losses and electricity consumed losses and to evaluate the hydro-energetic performance of the WSS in Brazil and world.
440

Análise de sistemas híbridos em estabelecimentos assistenciais de saúde (EAS) visando o conforto térmico e redução de consumo energético / Hybrid systems analysis in healthcare establishments aiming the thermal comfort and energy consumption reduction

Grimm, Ana Marta Aragão 08 October 2012 (has links)
No contexto de questões ambientais mundiais, os estabelecimentos assistenciais de saúde (EAS), devido a diversas mudanças apresentadas na fisiologia dos edifícios hospitalares nos últimos 100 anos, se inserem como grandes consumidores de energia. Tais alterações devem-se ao avanço das ciências médicas, a novas tecnologias em sistemas e equipamentos e ao crescimento populacional. O presente trabalho pretende analisar a contribuição do uso de tecnologias passivas em Estabelecimentos Assistenciais de Saúde (EAS) no que tange o desempenho térmico e energético, considerando normas específicas para este uso que exigem áreas assépticas através do uso de tecnologias ativas visando o controle da infecção hospitalar e a qualidade do ar interior. Esta configuração caracteriza para estes edifícios, sistemas híbridos com relação a tecnologias ativas e passivas. O caráter experimental da pesquisa foi realizado através de Simulação Computacional com o Software Energy Plus versão 7.0 em que foi analisado o desempenho térmico e energético de um edifício hospitalar. Inicialmente o edifício foi simulado em condições existentes e posteriormente foram realizadas diversas simulações com diferentes soluções arquitetônicas entre elas a inserção de tetoverde. / In the context of global environmental issues the Healthcare Establishments due to several changes on the physiology of hospital buildings over the past one hundred years have fallen as large energy consumers. Such changes were due to the advancement of medical science, new technologies in systems and equipments, and population growth. The present work intends to analyze the contribution of the use of passive technologies in Healthcare Establishments regarding the thermal and energetic performance considering specific standards for this use that demands aseptic areas through the use of active technologies aiming hospital infection control and indoor air quality. This configuration characterizes for these buildings hybrid systems related to active and passive technologies. The research\'s experimental character was made through Computer Simulation with the Software Energy Plus version 7.0 in which were analyzed the thermal and energetic performance of a hospital building. Initially the building was simulated in existing conditions and afterwards several simulations were made with different architectural solutions, in which was among them the insertion of a green roof.

Page generated in 0.7683 seconds