• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 289
  • 11
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 306
  • 142
  • 52
  • 51
  • 48
  • 35
  • 33
  • 33
  • 33
  • 33
  • 32
  • 31
  • 30
  • 26
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Projeto e construção de um medidor de corrente de eletrons emitidos no vacuo por campo eletrico para carcterização de catodos frios constituidos por nanotubos ou nanoestruturas / Design and construction of a current meter for field emitted electrons in vacuum for the characterization for nano-tube or nano-structured cold cathodes

Iannini, Roberto Fonseca 24 August 2005 (has links)
Orientador: Vitor Baranauskas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-05T07:21:22Z (GMT). No. of bitstreams: 1 Iannini_RobertoFonseca_M.pdf: 1222857 bytes, checksum: 41c44a25bef2f1656de6659dff1c5734 (MD5) Previous issue date: 2005 / Resumo: O progresso da pesquisa científica depende da qualidade e da disponibilidade de instrumentos confiáveis e de alta precisão, necessários para a exploração quantitativa de novos fenômenos, possibilitando a construção de modelos mais avançados e mais sofisticados. Um dos fenômenos que tem despertado grande interesse é a emissão de elétrons da superfície de catodos frios para o vácuo, sob a ação de campos elétricos externos. Para o estudo deste fenômeno, é necessária a medida de pequenas correntes em amostras que estão sob tensões elétricas relativamente altas. Nesta tese contribuímos com o projeto e construção de um medidor de corrente capaz de operar de maneira integrada à câmara de vácuo onde são analisadas as propriedades de emissão de nanotubos ou de materiais nanoestruturados. Foram desenvolvidos integralmente o hardware, firmware e software, com vistas à integração futura com outros instrumentos de controle e análise / Abstract: The progress of scientific research depends of the quality and availability of reliable and high precision instruments, which are necessary for measurement of new phenomena, making possible the construction of advanced and sophisticated models. One phenomenon that has being studied is the field emission of electrons from cold cathodes in vacuum, under external electrical field influence. In order to perform this study, it is necessary to measure small electrical currents with the surface sample under high voltage. In this thesis, we have contributed with the project and construction of a electric current meter able to operate in a vacuum chamber environment where the field emission properties of sample materials (nanotubes or nanostructures) are analyzed. Both hardware, firmware and software were developed looking forward to future integration of the measurement and control equipments / Mestrado / Instrumentação e Controle / Mestre em Engenharia Elétrica
152

Desenvolvimento experimental de uma camara para medida de emissão de eletrons por catodos frios / Development of a vacuum set-up for the measurement of cold cathode field electron emission

Amorim, Mauro Vanderlei de 13 December 2005 (has links)
Orientador: Vitor Baranauskas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-06T07:59:42Z (GMT). No. of bitstreams: 1 Amorim_MauroVanderleide_M.pdf: 4658675 bytes, checksum: 1d0d3ce62cb40cd86d00a29631b96508 (MD5) Previous issue date: 2005 / Resumo: Foi desenvolvida uma câmara de vácuo para estudo das propriedades elétricas de emissão de elétrons por catodos frios de vários materiais de interesse tecnológico, por exemplo, diamante dopado, filmes de carbono diamantífero e silício. Na parte experimental realizamos um sistema de alto vácuo (bomba mecânica mais a bomba difusora), um sistema de posicionamento de 6 graus de liberdade e um sistema de medida da corrente de emissão de elétrons. A modelagem matemática da emissão foi baseada na teoria de Fowler ¿ Nordheim. Foram feitos os cálculos relativos às propriedades de vácuo do sistema utilizado e a seguir a caracterização de algumas amostras de estruturas nanométricas produzidas utilizando o processo de deposição química a partir da fase vapor do etanol (HFCVD) com altas concentrações de hélio e argônio / Abstract: A vacuum chamber was developed for study the physical properties of electron emission by cold cathodes of several materials of technological interest as for example, doped diamond, films of diamond-like carbon and silicon. In the experimental part we accomplished a system of high vacuum (mechanic and diffusion pumps), a positioning system of 6 degrees of freedom and a system to measure of the electron emission current. The mathematical modeling of the emission was based on the theory of Fowler - Nordheim. Relative calculation of the properties of vacuum in the used system was made to check the characterization of some samples of nanometric structures produced using the process of chemical deposition starting from the phase vapor of the ethanol (HFCVD) with high concentrations of helium and argon / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
153

Estudo comparativo das seções de choque de excitações vibracionais de moléculas de hidrogênio por impacto de pósitrons e elétrons / Comparative study of vibracional excitation of hydrogen molecules by electron and positron impact

Hisi, Andréia Nalú Soares 24 March 2006 (has links)
Orientador: Marco Aurelio Pinheiro Lima / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-08-06T16:52:29Z (GMT). No. of bitstreams: 1 Hisi_AndreiaNaluSoares_M.pdf: 1775574 bytes, checksum: 25943a839a6bab51223d4a915fca5faf (MD5) Previous issue date: 2006 / Resumo: Neste trabalho realizamos cálculos comparativos para seções de choque de excitações vibracionais integrais e diferenciais para o espalhamento de pósitrons e elétrons de baixa energia contra a molécula de Hidrogênio (H2). Para estes cálculos utilizamos o Método Multicanal de Schwinger (SMC) [1] para a colisão de pósitrons [2] e colisão de elétrons [3]. Usando um conjunto de amplitudes de espalhamento oriundas do SMC, calculadas segundo uma quadratura específica (Hermite [4]) de pontos correspondendo à distâncias internucleares, obtivemos as seções de choque vibracionalmente resolvidas segundo a Aproximação Adiabática [5]. Para poder comparar o processo de espalhamento de elétrons com o de pósitrons, as amplitudes de espalhamento foram calculadas com o mesmo conjunto de base representando o alvo molecular e a função de espalhamento da partícula. Para a função de onda vibracional utilizamos as autofunções de um oscilador harmônico simples (com freqiiência experimental) para ambos os casos de espalhamento de elétron e pósitron / Abstract: Here we report a comparative calculation of both integral and differential vibrational excitation cross sections of low energy positron and electron scattering against Hydrogen molecules (H2). For these calculations we have used the Schwinger Multichannel (SMC) Method [1] for positron collision [2] and electron collision [3]. Using a set of SMC scattering amplitudes, calculated at specific quadrature points (Hermite [4]) of internuclear distances, we have obtained vibrational resolved cross sections in the Adiabatic Aproximation [5]. In order to compare the electron scattering process with the positron one, the scattering amplitudes were calculated with the same basis set for representing the molecular target and scattering particle wave functions. For the vibrational wave functions we have used the eigenfunctions of a simple harmonic oscillator (with the experimental frequency) for both cases, the electron and positron scattering / Mestrado / Física Atômica e Molecular / Mestre em Física
154

Efeito da radiação de eletrons na reparação tecidual

Almeida, Solange Maria de, 1959- 15 May 1996 (has links)
Orientador: Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T03:00:44Z (GMT). No. of bitstreams: 1 Almeida_SolangeMariade_D.pdf: 5623908 bytes, checksum: b26c68566d3a5cc890cf18e225a7c0c1 (MD5) Previous issue date: 1997 / Resumo: O presente trabalho teve como finalidade estudar o efeito de baixas doses de radiação de elétrons no processo de reparação tecidual em ratos. Para tanto, os animais sofreram um procedimento cirúrgico, onde foi produzida uma ferida retangular, medindo 2,3 cm por 1,4 cm, na sua região dorsal anterior. No momento da irradiação, as feridas produzidas foram protegidas, sendo irradiada somente uma região corresponde a 1,0 cm lateralmente à cada borda da ferida, com todo o restante do corpo do animal também protegido. A irradiação foi realizada para um grupo de animais, imediatamente após a abertura da ferida. O outro grupo sofreu a irradiação 3 dias após esse procedimento. O processo de reparação tecidual foi estudado aos 2, 4, 7, 11, 14, 17 e 21 dias após o procedimento cirúrgico para o primeiro grupo, enquanto para o segundo grupo de animais, a reparação tecidual foi avaliada 5, 7, 10, 14, 17, 20 e 24 dias também após a abertura da ferida. Cada grupo irradiado foi comparado com. grupos controles correspondentes, os quais não sofreram irradiação. O processo de reparação tecidual foi avaliado pelos seguintes métodos: coloração pela hematoxilina - eosina, que possibilitou avaliar a mortologia do tecido de granulação; reação histoquímica de metacromasia pelo azul de toluidina pH 4, podendo assim ser avaliada a síntese de glicosaminoglicanas e por fim, impregnação argêntica, onde foi observada a síntese de colágeno, através da microscopia de polarização (birrefringência). Os resultados obtidos mostraram que 1,0 Gy de radiação de elétrons com um feixe de 6 MéV, usou um retardo no processo de reparação tecidual, quando aplicado imediatamente e 3 dias após a abertura da ferida, sendo que quando comparados os dois grupos irradiados, para os dias 7, 14 e 17 , o efeito na reparação tecidual foi mais acentuado no grupo que sofreu irradiação 3 dias após a abertura da ferida / Abstract: The present search had the purpose to study the low dose electron irrradiation effect in the process of tissue repair in rats. In such a way, the animais were submitted to a surgical procedure, in which a rectangular wound was performed, measuring 2.3cm X 1.4cm on the fore dorsal area. At the moment of irradiation, the wounds were protected so that only an area near 1.0cm laterally to each b9rder of the wound was i rrad iated , being protected ali the rest ofthe animal body. The irradiation was performed in one group of animais immediately after the wounding procedure. The other group was irradiated three days after wounding. The process of tissue repair was studied at 2, 4, 7, 11, 14, 17 and 21 days after the surgical procedure on the first group, while for the other group of animais, tissue repair was evaluated at 5, 7, 10, 14, 17, 20 and 24 days, also after wounding. Each irradiated group was compared to corresponding control groups, which did not were submited irradiation. The tissue repair process was evaluated by the following methods: staining by haematoxylin-eosin in order to evaluating granulation tissue morphology; histochemical reaction of metachromasia by toluidin pH 4.0, so that it was possible to evaluate the synthesis of glucosaminglucans and at last, the silver impregnation, in which it was studied the collagen synthesis bymeans of polarizing microscopy. The results obtained showed that 1.0 Gy of electron irradiation with a 6 MeV beam caused a delay in the process of tissue repair, when applied immediately after and at three days after wounding. The comparison of both irradiated groups at days 7, 14 and 17, have showed that the effect on tissue repair was stronger on the group that received irradiation 3 days after wounding / Doutorado / Radiologia / Doutor em Odontologia
155

Tratamento do caso não semiclassico por separação do Hamiltoniano em uma parcela variacional e uma parcela Laplaciana aplicado a espectroscopia e a microscopia de tunelamento de eletrons

Carnevali Filho, Americo 27 July 2018 (has links)
Orientador : Vitor Baranauskas / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-27T22:12:52Z (GMT). No. of bitstreams: 1 CarnevaliFilho_Americo_D.pdf: 485925 bytes, checksum: b6d5679c6aa4cb2861c448d6423d18cc (MD5) Previous issue date: 2000 / Doutorado
156

Cálculo da dose de radiação através de convoluções em meios heterogêneos para aplicações em radioterapia

Perles, Luis Augusto 20 October 2000 (has links)
Orientador: Carola Dobrigkeit Chinellato / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-07-28T02:47:42Z (GMT). No. of bitstreams: 1 Perles_LuisAugusto_M.pdf: 1248295 bytes, checksum: 6cd75720bf40b787ab7f86ea6ca15b5b (MD5) Previous issue date: 2001 / Resumo: Nesta dissertação de mestrado apresentamos o estudo sobre uma técnica de convolução para o cálculo da distribuição da dose de radiação usada em teleterapia. Este método decompõe em três parcelas a distribuição da energia absorvida pelo meio: uma devida à dose do espalhamento primário, uma devida à dose do espalhamento secundário e uma terceira, devida aos espalhamentos de ordens superiores. Mostramos todo o desenvolvimento teórico do método de cálculo da dose de radiação por convoluções para meios homogêneos e heterogêneos, onde os tecidos moles são tratados todos como tendo a mesma seção de choque que a água. As heterogeneidades são tratadas como de densidades diferentes da água, porém com a mesma seção de choque da água. As funções de transporte de elétrons e fótons foram simuladas no EGS4. Fizemos os cálculos para a energia do 60Co e os resultados apresentaram uma boa concordância quando comparados a resultados experimentais e simulados para campos de até 10 x 10 cm2 a uma profundidade de 26 cm. Com o aumento das dimensões do campo, a profundidade em que há confiabilidade reduz-se. Este fato se deve ao espaço limitado em que o programa EGS4 realiza as simulações dos transportes de fótons de altas ordens de espalhamento. O programa desenvolvido para o cálculo da distribuição de dose de radiação nesta tese tem por objetivo servir de base para outros estudos e pesquisas relativas à aplicação deste método e também poderá ser usado no dia-a-dia da radioterapia após os devidos testes de confiabilidade / Abstract: In this thesis we have applied the convolution techniques to calculate the three dimensional (3D) dose distribution to be used in teletherapy. The convolution method spans the total dose in three parts: one due to the energy released by charged particles produced at the first collisions, one due to the energy released by the first scattered photons, and the last one due to photons of higher order scattering. We have shown up the theoretical development for homogeneous and inhomogeneous media. Cross sections of tissues have been approximated to water like. Heterogeneities are supposed to have the same cross sections as water and their densities have been treated as weight for the dose computations. Electron and photon functions were simulated in a previous step using EGS4. We have done the calculations for 60Co energy and the results have shown good agreement with experimental data sets for .elds less than 10 x 10 cm2 at 26 cm depth. For larger fields the depth of agreement was reduced. We have associated this fact to the limitation of simulation steps, during transport of photons of higher order scattering. The aim of the software developed to calculate the radiation dose distribution in this thesis is to be the basis for other studies and researches related. The appliance in radiotherapy routine will be evaluated after confiability tests / Mestrado / Física / Mestre em Física
157

Estudo do fenomeno de emissão de eletrons por campo eletrico em nanotubos de carbono / Study of the phenomenon of electron emission by electric field from carbon nanotubes

Pasquetto, Mariana Pinheiro 12 August 2018 (has links)
Orientador: Vitor Baranauskas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-12T17:45:44Z (GMT). No. of bitstreams: 1 Pasquetto_MarianaPinheiro_M.pdf: 2160996 bytes, checksum: c7df63c9eb3cc77d7d929e04f7b71d01 (MD5) Previous issue date: 2008 / Resumo: Materiais emissores de elétrons são extremamente importantes no ramo da micro e nano eletrônica, como por exemplo, em displays, microscópios eletrônicos, sensores de pressão. Para essas aplicações, podem ser usados catodos frios, ou seja, materiais que não necessitam ser aquecidos para emitirem elétrons. Através da aplicação de um campo elétrico local, aumenta-se a probabilidade dos elétrons tunelarem do sólido para o vácuo. Este é o fenômeno de emissão de campo. Essa dissertação apresenta os resultados da emissão de elétrons por efeito de campo elétrico (emissão de campo) de amostras de nanotubos de carbono, dopados e não-dopados com boro e nitrogênio. As amostras estudadas foram fornecidas pelo Laboratório de NanoEngenharia I do DSIF, FEEC. É feita, também, uma descrição da teoria de emissão de campo e de algumas aplicações desse fenômeno. Verificou-se que os materiais testados são bons emissores de elétrons. / Abstract: Electron emitter materials are extremely important in the field of micro and nano electronics, for example, in displays, electronic microscopes, pressure sensors. For such applications, cold cathodes can be used, that is, materials that do not need to be heated to emit electrons. Through the application of a local electric field, it is increased the probability of the electrons to tunnel from the solid. This is the phenomenon of field emission. This dissertation presents the results of the electron emission in the presence of an electric field (field emission) of samples of carbon nanotubes, undoped and doped with boron and nitrogen. The samples were provided by the Laboratório de NanoEngenharia I from DSIF, FEEC. It is also made a description of the field emission theory and of some applications of this phenomenon. It was found that the materials tested are good electron emitters. / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
158

Polarização do alvo molecular no espalhamento de elétrons / Polarization of molecular target in electron scattering

Lopes, Adriana do Rocio 15 May 2007 (has links)
Orientadores: Marco Aurelio Pinheiro Lima, Marcio Henrique Franco Bettega / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-09T02:36:32Z (GMT). No. of bitstreams: 1 Lopes_AdrianadoRocio_D.pdf: 1199450 bytes, checksum: 35d2c55fd54d591ec1c7417e228b3cf2 (MD5) Previous issue date: 2007 / Resumo: O objetivo principal desse trabalho foi a inclusão dos efeitos de polarização nos cálculos de seção de choque de espalhamento utilizando potenciais modelo. A implementação foi feita no método multicanal de Schwinger com pseudopotencial, utilizando uma descrição do potencial de polarização através de uma combinação de funções gaussianas. Com esse potencial, visamos diminuir o custo computacional existente na inclusão do efeito de polarização em um cálculo ab-initio. Utilizamos três potenciais conhecidos na literatura, sendo o primeiro o potencial que relaciona um efeito de curto alcance (correlação), derivado de um modelo de gás de elétrons livres, com o longo alcance (polarização). O segundo potencial possui a forma mais simples, constante para raios perto da origem, e decai como um potencial de polarização. O terceiro potencial possui um fator exponencial que faz o seu valor ser próximo de zero na origem e decai como um potencial de polarização. Apresentamos um modelo de polarização descrito pelo deslocamento da densidade de carga com um parâmetro calculado de forma ab-initio. Utilizando o terceiro potencial modelo calculamos a seção de choque integral, de transferência de momento e diferencial para as moléculas de CH4, SiH4, GeH4, PbH4, SnH4, CF4 e SiF4. Os resultados obtidos foram comparados com os dados existentes na literatura e obtivemos uma boa concordância entre eles / Abstract: The aim of this work is the inclusion of polarization effects in the calculations of scattering cross section by using model potentials. The implementation was made in the Schwinger multichannel method with pseudopotentials, using a description of polarization potential with gaussians functions. With this potential we entend to reduce the computational cost present in the inclusion of polarization effects through ab-initio calculation. We use three potentials that can be found in the literature. The first potential relates the short range effect (correlation) derivated from a free electron gas model, with the long range effect (polarization). The second potential has the simplest form, for radius close to zero the potential tends to a constant, and for large r it decays like a polarization potential. The third potential has a exponential factor that is zero in the origin and it decays like a polarization potential for large r. We present a polarization model described by a displacement of a eletric charge density with a ab-initio calculated parameter. Using the third model potential we calculated the integral, momentum transfer and diferential cross section for CH4, SiH4, GeH4, PbH4, SnH4, CF4and Si F4molecules. Our results had been compared with experimental data and we have good agreement / Doutorado / Física Atômica e Molecular / Doutor em Ciências
159

Emissão de eletrons por efeito de campo em diamante policristalino dopado com boro e desenvolvimento de um novo sistema de ultra alvo vacuo / Electron field emission from boron doped microcrystalline diamond and development of a new ultra high vacuum system

Roos, Mathias 12 October 2007 (has links)
Orientador: Vitor Baranauskas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T10:03:42Z (GMT). No. of bitstreams: 1 Roos_Mathias_M.pdf: 4816472 bytes, checksum: 51a357faa29ccbd01723b1d6ca5abf27 (MD5) Previous issue date: 2007 / Resumo: Na primeira parte deste trabalho amostras de diamante poli-cristalino dopado com boro foram crescidas por deposição química a vapor assistida por filamento quente. As características de emissão de campo foram investigadas. A dopagem (NB) em amostras diferentes foi variada pelo controle da concentração B/C no fluxo de gases durante o processo de crescimento. Os campos limiares (Eth) para emissão de campo foram medidos e relacionados com as concentrações B/C usadas. Assim, a influência das bordas entre os grãos, a dopagem e a morfologia da superfície na emissão de campo foram investigadas. A saturação da dopagem foi observada para altas concentrações B/C. O transporte de cargas através das bordas entre os grãos e as propriedades locais de emissão na superfície foram modeladas por dois mecanismos que afetam a emissão de campo. Correntes de emissão de 500 nA·cm-2 foram obtidas para campos elétricos de 8 V·µm-1. Na segunda parte desta tese, a construção de um novo sistema de ultra alto vácuo (UHV) para realizar medições de emissão de campo é descrita. A construção inclui o projeto integral de uma câmara de UHV com sistema de bombas, conjunto de manipuladores, suportes mecânicos e a infraestrutura do laboratório / Abstract: In the first part of this thesis, the study of field emission properties of hot filament chemical vapor deposited boron doped polycrystalline diamond is described. The doping level (NB) of different samples was varied controlling the B/C concentration in the gas feed during the growth processes. The threshold field (Eth) for electron emission in dependence on different B/C concentrations was measured and the influence of grain boundaries, doping level and surface morphology on the field emission properties was investigated. For high B/C ratios doping saturation was observed. Carrier transport through conductive grains and local emission properties of surface sites figured out to be two independent limiting effects on field emission. Emitter currents of 500 nA·cm-2 were obtained using electric fields less than 8 V·µm-1. In the second part the construction of a new UHV system for field emission measurements is described, including the complete project of a UHV chamber with pump system, manipulators and sample transfer system, mechanical supports and the infrastructural requirements of the laboratory / Mestrado / Eletrônica, Microeletrônica e Optoeletrônica / Mestre em Engenharia Elétrica
160

Implantação de um analisador de baixas energias de elétrons com resolução angular em um espectrômetro de perda de energia de elétrons

Duque, Humberto Vargas 19 June 2012 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-10T14:00:21Z No. of bitstreams: 1 humbertovargasduque (1).pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor corrigir: Membro da banca: Filho, Jayr de Amorim on 2018-01-23T11:49:04Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-23T13:12:19Z No. of bitstreams: 1 humbertovargasduque (1).pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor verificar nome do arquivo, existe o número (1) humbertovargasduque (1).pdf on 2018-01-23T13:14:55Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-23T13:22:21Z No. of bitstreams: 1 humbertovargasduque.pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-01-24T13:40:22Z (GMT) No. of bitstreams: 1 humbertovargasduque.pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) / Made available in DSpace on 2018-01-24T13:40:22Z (GMT). No. of bitstreams: 1 humbertovargasduque.pdf: 2897920 bytes, checksum: 904a8ff36edd0079149dfe6e3be69aed (MD5) Previous issue date: 2012-06-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho consiste no desenvolvimento, implantação e caracterização de um Analisador Cilíndrico Dispersivo 1270 em um Espectrômetro de Perda de Energia de Elétrons (EPEE) operando na região de energia de impacto de 10 a 200 eV, que está sendo desenvolvido no Laboratório de Espectroscopia Atômica e Molecular – LEAM da UFJF. Além do analisador, foram também desenvolvidos diversos trabalhos para otimização do circuito de controle do canhão de elétrons monocromatizado do EPEE, o que gerou ótima estabilidade, acarretando em um ganho considerável em intensidade do feixe produzido e melhoria no manuseio do mesmo. É descrito a implementação da variação angular da plataforma giratória que apóia o Analisador Cilíndrico Dispersivo 1270, bem como a medida desta variação, e também, do sistema de injeção do feixe gasoso através de uma cânula de molibidênio isolada eletricamente, com movimento verticalem relação ao disco onde estão instalados o canhão e analisador. Os testes de desempenho do Espectrômetro foram feitos a partir da análise da resolução de Energia ΔE do EPEE. Obtivemos ótimos resultados quanto a transmissão do feixe de elétrons monocromatizado através da região de colisão chegando até a região de detecção do espectrômetro. É descrito, também, uma avaliação das melhorias feitas no Circuito de Controle do Canhão de Elétrons Monocromatizado, obtendo excelentes resultados quanto a intensidade do feixe de elétrons na faixa de energia de 0,1-100 eV. / This work describes the development, implementation and characterization of a Cylindrical Dispersive Analyzer 1270 on a Electron Energy Loss Spectrometer (EELS) operating in the region of impact energy from 10 to 200eV, which is being developed at the Laboratory of Atomic Spectroscopy and Molecular – LEAM UFJF. In the analyzer, several studies have also been developed to optimize the control circuit of the monochromatized electron gun of the EELS, which generated great stability, resulting in a considerable gain in intensity of the beam produced and improved handling. We describe the implementation of the angular variation of the turntable that supports the Cylindrical Dispersive Analyzer 1270, and the measure of variation, and also injection system of the gas through a beam cannula molybdenum electrically isolated, with vertical movement relative to disk where the monochromatized electron gun and the energy analyzer of electrons are installed. Performance tests of the spectrometer were made from the analysis of the energy resolution ΔE of the EELS. We obtained excellent results about transmission of the electron beam across the monochromatization region collision reaching the detection region of the spectrometer. We describe also an assessment of the improvements made in the Control Circuit of the Monochromatized Electron Gun, obtaining excellent results for the intensity of the electron beam in the energy range 0.1-100 eV.

Page generated in 0.0509 seconds