• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 13
  • 2
  • 1
  • 1
  • Tagged with
  • 74
  • 74
  • 36
  • 33
  • 19
  • 18
  • 16
  • 14
  • 14
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Detecção de falhas estruturais usando sensores e atuadores piezelétricos e algoritmos genéticos /

Tebaldi, Adriano. January 2004 (has links)
Orientador: Vicente Lopes Júnior / Banca: Paulo Carlos Kaminski / Banca: Walter Katsumi Sakamoto / Resumo: A tecnologia de materiais inteligentes se tornou uma área de crescente interesse para o desenvolvimento de estruturas que podem incorporar atuadores e sensores capazes de detectar falhas. Extensivas investigações têm sido focadas na tecnologia que integra materiais inteligentes no monitoramento das condições de sistemas. Vários estudos têm sido realizados na área de identificação de sistemas mecânicos e há uma tendência de introduzir otimização em projetos de monitoramento de sinais que permitirá automatização do processo e caracterização de falhas para sistemas complexos. O problema de identificação de variáveis ou detecção de falhas em sistemas mecânicos é uma classe de problemas inversos e, portanto, não apresenta uma solução única. O problema inverso consiste em determinar as causas baseando-se na observação dos efeitos. Nos problemas inversos os parâmetros de falha (comprimento de trinca e/ou localização) podem ser calculados no domínio da freqüência ou do tempo. A metodologia proposta neste trabalho utiliza dados no domínio da freqüência, e utiliza, em uma primeira etapa, o método da impedância elétrica para se determinar a localização das falhas. Numa segunda etapa é realizada a quantificação da intensidade de falhas, usando algoritmos genéticos. Algoritmos genéticos (AG) são processos de otimização baseados nos princípios de evolução natural. Um AG simula um processo de adaptação em uma população inicial de indivíduos através de operadores genéticos artificiais em cada geração. Em condições de otimização, cada indivíduo da população é codificado em um cromossomo, que representa uma solução genérica para o problema, enquanto a adaptação individual é avaliada por uma função de aptidão. / Abstract: Smart material technology has become an area of increasing interest for the development of structures that are able to incorporate actuator and sensor capabilities for fault detection. Extensive investigations have been focused on integrating smart material technology into health monitoring systems. Several studies have been accomplished in the area of identification of mechanical systems and there is a tendency of introducing optimization in projects of signals monitoring, which would allow automation in the process and characterization of faults, even for complex systems. The problem of variables identification or damage detection in mechanical systems is a class of inverse problem and, therefore, it doesn't present a unique solution. The inverse problem consists in determining the causes based on some observation of their effects. In inverse problems the damaged parameters (crack length and/or location) can be calculated in frequency or time domain. The proposal methodology is based on frequency domain, and it uses, in a first stage, the method of electric impedance to determine the location of the faults. Later on takes place the quantification of the fault intensities, in a second stage, by using genetic algorithms. Genetic algorithms (GA) are optimization processes based on principles of natural evolution. A GA simulates an adaptation process taking an initial population of individuals and applying artificial genetic operators in each generation. In optimization conditions, each individual of the population is coded in a string or chromosomes, which represents a trial solution for a certain problem, while the individual adaptation is evaluated through a fitness function. / Mestre
42

Desenvolvimento de uma metodologia para identificação de região cardíaca em imagens de tomografia de impedância elétrica de perfusão pulmonar por meio da transformada wavelet / Development of a methodology for identification of cardiac region in images of electrical impedance tomography of pulmonary perfusion by means of wavelet transform

José Pedro de Oliveira 14 September 2009 (has links)
A Tomografia de Impedância Elétrica (TIE) é uma técnica de imageamento, ainda em desenvolvimento, por meio da qual são extraídas imagens correspondentes à distribuição da impedância elétrica de uma seção transversal de um objeto sob análise a partir de medidas elétricas realizadas em sua superfície. Apesar de seus benefícios e vantagens sobre outras técnicas de imageamento, suas imagens não oferecem uma boa resolução espacial. Em imagens TIE de tórax, um dos maiores desafios reside no tratamento da perfusão pulmonar, pois as perspectivas de uso clínico são inúmeras. Assim sendo, melhorar a localização de seus principais órgãos é um dos grandes objetivos. Com o intuito de melhorar a resolução anatômica foi desenvolvida uma metodologia para identificação de região cardíaca em imagens de tomografia de impedância elétrica de perfusão pulmonar por meio da transformada wavelet, utilizando imagens TIE de porcos. Inicialmente foi realizada uma série de estudos de diferentes abordagens com vistas a identificar aquelas características que pudessem indicar similaridades ou diferenças intrínsecas entre os pixels de diferentes regiões anatômicas. Com base nestes estudos, cinco métodos baseados na análise wavelet foram desenvolvidos. Um primeiro conjunto de experimentos, realizado em um único porco, foi utilizado no desenvolvimento e aperfeiçoamento dos métodos. Posteriormente, outros experimentos, envolvendo quatro porcos em diferentes condições fisiológicas, foram utilizados na avaliação de desempenho destes métodos. As imagens de perfusão wavelet foram comparadas com as imagens de perfusão obtidas pelo método de injeção de uma solução hipertônica, considerada como padrão de referência das imagens de perfusão. A metodologia wavelet proposta por este trabalho foi o método, dentre os cinco desenvolvidos, que obteve os melhores resultados. Ela foi capaz de identificar a região cardíaca de cinco porcos submetidos a diversas condições fisiológicas, demonstrando robustez e resultados muito satisfatórios, não apenas em termos quantitativos, com uma área média da curva ROC de 0,86, mas também na qualidade das imagens obtidas, onde os contornos delimitando a região cardíaca ficaram bem definidos e de formato circular, de acordo com o que se esperava. Portanto, o objetivo maior deste trabalho que era melhorar a resolução espacial de imagens TIE de perfusão pulmonar, foi atingido com excelentes resultados e vantagens adicionais, como por exemplo, a possibilidade de sua implementação em equipamentos TIE de monitoramento do tórax e desta forma colaborar no aperfeiçoamento de sistemas de apoio à decisão médica em ambientes críticos, como é o caso das Unidades de Terapia Intensiva (UTIs). / Electrical Impedance Tomography (EIT) is an imaging technique, still in development, which allows imaging of the distribution of conductivity in a cross section of an object under analysis from electrical measures made on its surface. Despite its benefits and advantages over other imaging techniques, its images still do not offer a good spatial resolution. One of the biggest challenges in EIT thorax images is the treatment of the lung perfusion because the perspectives for clinical use are numerous. Thus, there is a great interest in improving the localization of its main organs. In order to improve the anatomical resolution was developed a methodology for identification of cardiac region in images of electrical impedance tomography of pulmonary perfusion by means of wavelet transform, using EIT images of pigs. Some preliminary studies of different approaches were performed in order to identify those characteristics that would indicate intrinsic similarities or differences among the pixels of different anatomical regions. These studies propitiated the development of five methods based on wavelet transform. A first set of experiments, performed in a single pig, was used in developing and improving of the methods. Subsequently, other experiments, involving four pigs in different physiological conditions, were performed to evaluate the performance of these methods. The wavelet perfusional images were compared with the perfusional images obtained by the method of injection of a hypertonic solution, considered as the perfusional reference standard images. Amongst the five developed methods, the best of them was selected as the wavelet methodology proposed by this work. It was capable to identify the heart region of five pigs under different physiological conditions, demonstrating to robustness and very satisfactory results, not only in quantitative terms, with an average area of the ROC curve of 0.86, but also in the quality of the images, where the contours delimiting the cardiac region were well defined and of circular format, according to what was expected. Therefore, the main objective of this work, that was to improve the spatial resolution of EIT images of pulmonary perfusion, was reached with excellent results and additional benefits such as the possibility of its implementation in EIT equipments for monitoring thorax and thus collaborate in improving of medical decision support systems in critical environments, as for example the Intensive Care Units (ICUs).
43

Desenvolvimento de uma metodologia para identificação de região cardíaca em imagens de tomografia de impedância elétrica de perfusão pulmonar por meio da transformada wavelet / Development of a methodology for identification of cardiac region in images of electrical impedance tomography of pulmonary perfusion by means of wavelet transform

Oliveira, José Pedro de 14 September 2009 (has links)
A Tomografia de Impedância Elétrica (TIE) é uma técnica de imageamento, ainda em desenvolvimento, por meio da qual são extraídas imagens correspondentes à distribuição da impedância elétrica de uma seção transversal de um objeto sob análise a partir de medidas elétricas realizadas em sua superfície. Apesar de seus benefícios e vantagens sobre outras técnicas de imageamento, suas imagens não oferecem uma boa resolução espacial. Em imagens TIE de tórax, um dos maiores desafios reside no tratamento da perfusão pulmonar, pois as perspectivas de uso clínico são inúmeras. Assim sendo, melhorar a localização de seus principais órgãos é um dos grandes objetivos. Com o intuito de melhorar a resolução anatômica foi desenvolvida uma metodologia para identificação de região cardíaca em imagens de tomografia de impedância elétrica de perfusão pulmonar por meio da transformada wavelet, utilizando imagens TIE de porcos. Inicialmente foi realizada uma série de estudos de diferentes abordagens com vistas a identificar aquelas características que pudessem indicar similaridades ou diferenças intrínsecas entre os pixels de diferentes regiões anatômicas. Com base nestes estudos, cinco métodos baseados na análise wavelet foram desenvolvidos. Um primeiro conjunto de experimentos, realizado em um único porco, foi utilizado no desenvolvimento e aperfeiçoamento dos métodos. Posteriormente, outros experimentos, envolvendo quatro porcos em diferentes condições fisiológicas, foram utilizados na avaliação de desempenho destes métodos. As imagens de perfusão wavelet foram comparadas com as imagens de perfusão obtidas pelo método de injeção de uma solução hipertônica, considerada como padrão de referência das imagens de perfusão. A metodologia wavelet proposta por este trabalho foi o método, dentre os cinco desenvolvidos, que obteve os melhores resultados. Ela foi capaz de identificar a região cardíaca de cinco porcos submetidos a diversas condições fisiológicas, demonstrando robustez e resultados muito satisfatórios, não apenas em termos quantitativos, com uma área média da curva ROC de 0,86, mas também na qualidade das imagens obtidas, onde os contornos delimitando a região cardíaca ficaram bem definidos e de formato circular, de acordo com o que se esperava. Portanto, o objetivo maior deste trabalho que era melhorar a resolução espacial de imagens TIE de perfusão pulmonar, foi atingido com excelentes resultados e vantagens adicionais, como por exemplo, a possibilidade de sua implementação em equipamentos TIE de monitoramento do tórax e desta forma colaborar no aperfeiçoamento de sistemas de apoio à decisão médica em ambientes críticos, como é o caso das Unidades de Terapia Intensiva (UTIs). / Electrical Impedance Tomography (EIT) is an imaging technique, still in development, which allows imaging of the distribution of conductivity in a cross section of an object under analysis from electrical measures made on its surface. Despite its benefits and advantages over other imaging techniques, its images still do not offer a good spatial resolution. One of the biggest challenges in EIT thorax images is the treatment of the lung perfusion because the perspectives for clinical use are numerous. Thus, there is a great interest in improving the localization of its main organs. In order to improve the anatomical resolution was developed a methodology for identification of cardiac region in images of electrical impedance tomography of pulmonary perfusion by means of wavelet transform, using EIT images of pigs. Some preliminary studies of different approaches were performed in order to identify those characteristics that would indicate intrinsic similarities or differences among the pixels of different anatomical regions. These studies propitiated the development of five methods based on wavelet transform. A first set of experiments, performed in a single pig, was used in developing and improving of the methods. Subsequently, other experiments, involving four pigs in different physiological conditions, were performed to evaluate the performance of these methods. The wavelet perfusional images were compared with the perfusional images obtained by the method of injection of a hypertonic solution, considered as the perfusional reference standard images. Amongst the five developed methods, the best of them was selected as the wavelet methodology proposed by this work. It was capable to identify the heart region of five pigs under different physiological conditions, demonstrating to robustness and very satisfactory results, not only in quantitative terms, with an average area of the ROC curve of 0.86, but also in the quality of the images, where the contours delimiting the cardiac region were well defined and of circular format, according to what was expected. Therefore, the main objective of this work, that was to improve the spatial resolution of EIT images of pulmonary perfusion, was reached with excellent results and additional benefits such as the possibility of its implementation in EIT equipments for monitoring thorax and thus collaborate in improving of medical decision support systems in critical environments, as for example the Intensive Care Units (ICUs).
44

Identificação de falhas estruturais usando sensores e atuadores piezelétricos e redes neurais artificiais

Furtado, Rogério Mendonça [UNESP] 20 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:14Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-20Bitstream added on 2014-06-13T18:55:44Z : No. of bitstreams: 1 furtado_rm_me_ilha.pdf: 1436216 bytes, checksum: 09e5f73855e5a468589756fca572b577 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A proposta deste trabalho é a obtenção de uma metodologia robusta para identificação de falhas estruturais combinando as vantagens de duas metodologias, que não são baseadas em modelos matemáticos, ou seja: impedância elétrica obtida com atuador e sensor piezocerâmico(materiais inteligentes) e redes neurais artificiais. O termo materiais inteligentes (smart materials) conhecido também por material ativo é dado a uma classe de material que exibe propriedades não encontradas em materiais convencionais. Alguns destes materiais são: compostos de materiais piezelétricos, eletrorresistivo e magnetorresistivo, fluidos e sólidos electro-reológicos, e outros. Uma das principais características do PZT (Titanato Zirconato de Chumbo), que permite utilizá-lo como sensor e atuador, é o efeito piezelétrico, ou seja, a aplicação de um campo elétrico resulta em deformação do material (efeito inverso), enquanto, a aplicação de tensão mecânica resulta no surgimento de um campo elétrico (efeito direto). Estas características associadas ao conceito de impedância elétrica e ao conceito de falha métrica permitem a localização e o monitoramento da falha. Esta técnica utiliza altas freqüências e excita os modos locais, proporcionando, assim, o monitoramento de qualquer mudança da impedância mecânica estrutural na região de influência do PZT. Redes neurais artificiais (RNA) fazem parte de um amplo conceito chamado inteligência artificial. Redes neurais têm sua base associada ao funcionamento do cérebro humano, que após treinamento possuem a capacidade de aprender. Esta ciência é objeto de estudo em diversos centros de pesquisa e, embora já tenha grande aplicabilidade, o sucesso de sua utilização depende do caso em que está sendo aplicada e de certa sutileza do projetista, uma vez que o processo ainda é empírico e teorias ainda... . / The proposal of this work is the obtaining of a robust methodology for identification of structural faults combining the advantages of two methodologies, which are not based on mathematical models. The methodology applies electric impedance technique, obtained with actuator and sensor piezoceramic (smart materials), and artificial neural networks. The term smart materials is given for a material class that not exhibits properties found in conventional materials. Some of these materials are: composed of piezoelectric material, electrostrictive and magnetostrictive, electrorheological fluids and solids shape memory alloys, and others. One of the main characteristics of PZT (Lead Zirconate Titanate), that allows to use it as sensor and actuator, is the piezoelectric effect, where the application of an electric field results in deformation of the material (inverse effect), while the application of mechanical tension results in the appearance of an electric field (direct effect). These characteristics associated to the concept of electric impedance and the concept of metric fault allow the location and the monitoring of the fault. This technique uses high frequencies and low voltage and it excites local modes, providing, the monitoring of any change on the structural mechanical impedance in the area of influence of the PZT. Artificial Neural Networks (ANN) are part of a wide concept called artificial intelligence. Neural networks has its base associated to the operation of the human brain, that after training possess the capacity to learn. This science is a study object in several research centers and, although it already has great application. The success of its use depends of the case and planner's certain keenness, once the process is still empiric and theories are still being formulated. Several conceptions of neural networks... (Complete abstract, click electronic address below).
45

Investigação da resistência a corrosão da liga Ti-13Nb-13Zr por meio de técnicas eletroquímicas e de análise de superfície

ASSIS, SERGIO L. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:10Z (GMT). No. of bitstreams: 1 11326.pdf: 1707325 bytes, checksum: f4b793f522e5d69e25de853d166b1c79 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
46

A influência do ferro e do óxido de cério sobre a condutividade elétrica e a resistência à corrosão do alumínio anodizado / The iron and cerium oxide influence on the electric conductivity and the corrosion resistance of anodized aluminum

SOUZA, KELLIE P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:36Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
47

Investigação da resistência a corrosão da liga Ti-13Nb-13Zr por meio de técnicas eletroquímicas e de análise de superfície

ASSIS, SERGIO L. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:29Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:10Z (GMT). No. of bitstreams: 1 11326.pdf: 1707325 bytes, checksum: f4b793f522e5d69e25de853d166b1c79 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
48

A influência do ferro e do óxido de cério sobre a condutividade elétrica e a resistência à corrosão do alumínio anodizado / The iron and cerium oxide influence on the electric conductivity and the corrosion resistance of anodized aluminum

SOUZA, KELLIE P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:36Z (GMT). No. of bitstreams: 0 / Investiga-se a influência de diferentes tratamentos sobre o sistema alumínio com cobertura de óxido de alumínio. A anodização do alumínio em meio de ácido sulfúrico e meio misto de sulfúrico e fosfórico foi empregada para alterar a resistência à corrosão, a espessura, o grau de cobertura e a microdureza do óxido anódico; e a eletrodeposição de ferro no interior óxido anódico em meio de sulfato com tratamento químico de selagem com cério, para alterar a sua condutividade elétrica e a sua resistência à corrosão. Para a eletrodeposição de ferro aplicou-se corrente contínua e pulsada e diversificou-se a composição do eletrólito de Fe(SO4)2(NH4)2.6H2O, com a adição dos ácidos bórico e ascórbico e para o tratamento de selagem, variou-se a concentração do CeCl3. A espectroscopia de energia dispersiva de raios X (EDS), a fluorescência de raios X (FRX) e a análise morfológica por microscopia eletrônica de varredura (MEV) permitiram verificar que, a corrente pulsada eleva o teor de ferro na camada anódica e a presença dos aditivos inibe a oxidação do ferro. As curvas cronopotenciométricas obtidas durante a eletrodeposição de ferro indicaram que a mistura dos ácidos bórico e ascórbico aumentaram a eficiência do processo de eletrodeposição. A espectroscopia de impedância eletroquímica (EIE), medidas de microdureza Vickers (H) e análise morfológica evidenciaram que o tratamento de selagem melhora a resistência à corrosão do filme óxido modificado com ferro. As medidas de impedância elétrica por duas pontas permitiram comprovar o aumento da condutividade elétrica do alumínio anodizado com ferro, mesmo após o tratamento com baixas concentrações de cério. Nanofios de ferro foram preparados utilizando os poros do óxido anódico como matriz. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
49

Estudo das características eletroquímicas e microestruturais de eletrodos de hidreto metálico à base de LaNi com adições de elementos de liga / Study of electrochemical and microstructural characteristics of lani-based metallic hydride electrodes with alloying additions

ZARPELON, LIA M. 10 March 2017 (has links)
Submitted by Mery Piedad Zamudio Igami (mery@ipen.br) on 2017-03-10T15:20:01Z No. of bitstreams: 1 22060.pdf: 3959215 bytes, checksum: 0a58b276270c30e02d2f6935bafba229 (MD5) / Made available in DSpace on 2017-03-10T15:20:01Z (GMT). No. of bitstreams: 1 22060.pdf: 3959215 bytes, checksum: 0a58b276270c30e02d2f6935bafba229 (MD5) / Neste trabalho avaliou-se a ação positiva da substituição de lantânio por praseodímio e de lantânio por magnésio na performance eletroquímica de eletrodos de ligas de armazenamento de hidrogênio em estado bruto de fusão e com tratamento térmico. O La foi substituído por Mg nas ligas La0,7-xMgxPr0,3Al0,3Mn0,4Co0,5Ni3,8 (x=0,0-0,7) e por Pr nas ligas La0,7-yPryMg0,3Al0,3Mn0,4Co0,5Ni3,8 (y=0,0-0,7). Os parâmetros eletroquímicos analisados foram ativação, capacidade de descarga, retenção da capacidade de descarga, autodescarga e alta taxa de descarga. As ligas apresentaram comportamento passivo em relação à corrosão. As análises por MEV/EDS e por DRX com refinamento por Rietveld revelaram a presença majoritária de fases similares às fases LaNi5, PrNi5, LaMg2Ni9 e PrMg2Ni9 em função das composições das ligas estudadas. Os parâmetros de rede e os volumes da célula unitária das fases diminuíram com a substituição crescente de La por Mg e de La por Pr. As capacidades de descarga máxima decresceram com a substituição crescente de La por Mg e de La por Pr, acompanhando o decréscimo da abundância da fase similar à fase LaNi5 e o aumento da abundância da fase similar à fase LaMg2Ni9. Comparativamente, menores taxas de autodescarga e maior estabilidade cíclica foram observadas para o eletrodo da liga na condição x=0,1, ao passo que o eletrodo da liga na condição y=0,0 apresentou maiores valores de alta taxa de descarga, indicando melhor performance cinética. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
50

Desenvolvimento de membranas aniônicas obtidas por enxertia via irradiação para aplicação em células a combustível alcalinas / Development of anionic membranes produced by radiation-grafting for alkaline fuel cell applications

PEREIRA, CLOTILDE C. 09 November 2017 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2017-11-09T12:16:30Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-09T12:16:30Z (GMT). No. of bitstreams: 0 / As membranas de troca aniônica são uma alternativa promissora para o desenvolvimento de eletrólitos mais eficientes para células a combustível alcalinas. Em geral, as membranas de troca aniônica são ionômeros capazes de conduzir íons hidroxila devido aos grupos quaternário de amônio e têm como característica elevado pH equivalente. Com o objetivo de desenvolver membranas aniônicas química e termicamente estáveis, com satisfatória condutividade iônica para aplicação em células a combustível alcalinas, as membranas aniônicas foram sintetizadas a partir de polímeros base de polietileno de baixa densidade (LDPE), polietileno de ultra alto peso molecular (PEUHMW), poli(etileno-co-tetrafluoroetileno) (PETFE) e poli(tetrafluoroetilleno-co-hexafluoroetileno) (PFEP) previamente irradiados nas fontes de radiação gama de 60Co ou com feixe de elétrons, para enxertia do monômero de estireno e funcionalizados com trimetilamina para incorporação dos grupos quaternário de amônio. As membranas resultantes foram caracterizadas por espectroscopia de ressonância paramagnética eletrônica (EPR), espectroscopia Raman, termogravimetria (TG), espectroscopia de impedância eletroquímica (EIS), além da determinação do grau de enxertia, capacidade de absorção de água por gravimetria e capacidade de troca iônica, por titulação. As membranas sintetizadas com os polímeros LDPE e UHMWPE pré-irradiados a 70 kGy com feixe de elétrons e armazenadas a baixa temperatura (-70 °C) por até 10 meses, mostraram resultados de condutividade iônica, quando na forma (OH-), de 29 mS.cm-1 e 14 mS.cm-1 a 65 °C, respectivamente. Os filmes de PFEP irradiados no processo simultâneo mostram níveis de enxertia insuficientes para a síntese de membranas aniônicas, necessitando maiores estudos para aperfeiçoar os processos de irradiação e enxertia. As membranas baseadas em PETFE, pré-irradiadas a 70 kGy com feixe de elétrons e armazenadas a baixa temperatura (-70 °C) por até 10 meses, mostraram maior condutividade iônica, quando na forma hidroxila (OH-), com valores de condutividade iônica entre 90 mS.cm-1 e 165 mS.cm-1 na faixa de temperatura entre 30 e 60 °C. Estes resultados mostraram que membranas de LDPE, UHMWPE e PETFE são eletrólitos promissores para a aplicação em células a combustível alcalinas. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1782 seconds