• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 13
  • 2
  • 1
  • 1
  • Tagged with
  • 74
  • 74
  • 36
  • 33
  • 19
  • 18
  • 16
  • 14
  • 14
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Estudo da resistência à corrosão das ligas de alumínio 2024-T3 e 7475-T651 soldadas por fricção e mistura (FSW) / Study of the corrosion resistance of aluminium alloys 2024-T3 and 7475-T651 welded by friction stir welding (FSW)

BUGARIN, ALINE de F.S. 21 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-21T11:56:39Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-21T11:56:39Z (GMT). No. of bitstreams: 0 / O processo de soldagem por fricção e mistura (FSW) tem despertado grande interesse nos últimos anos e tornou-se uma alternativa para unir materiais de baixa soldabilidade, como as ligas de alumínio das séries 2XXX e 7XXX, as quais são empregadas na estrutura das aeronaves, por possuírem elevada relação resistência/peso. O processo FSW, todavia, causa mudanças microestruturais nos materiais soldados, particularmente na zona misturada (ZM) e nas zonas termicamente (ZTA) ou termomecanicamente (ZTMA) afetadas. Estas mudanças geralmente interferem no desempenho frente à corrosão das ligas soldadas. No presente estudo, a resistência à corrosão das ligas de alumínio 2024-T3 e 7475-T761, unidas pelo processo FSW foi investigada em solução 10 mM de NaCl. Ensaios de visualização em gel ágar-ágar e de imersão associados a técnicas microscópicas foram realizados para investigar o efeito do acoplamento galvânico na corrosão das diferentes regiões da junta soldada. Os resultados do ensaio de visualização em gel mostraram que, quando acopladas, a liga 2024 atua como cátodo e a 7475 como ânodo. Os ensaios de imersão revelaram acoplamento galvânico entre as ligas na zona misturada (ZM). A região mais afetada pela corrosão foi a ZTMA da liga 7475, com corrosão intergranular desde as primeiras horas de imersão. A influência do processo de soldagem na resistência à corrosão das duas ligas de alumínio foi investigada por ensaios eletroquímicos. Os ensaios eletroquímicos adotados foram medidas de potencial de circuito aberto (PCA) em função do tempo de exposição ao meio corrosivo, espectroscopia de impedância eletroquímica (EIE) e curvas de polarização potenciodinâmica. Os ensaios de polarização mostraram elevada atividade eletroquímica na zona de mistura indicada pelos altos valores de densidade de corrente em comparação com as demais zonas testadas. Os resultados de EIE globais mostraram que nas primeiras horas de exposição ao eletrólito o processo de corrosão foi predominantemente controlado pela liga 7475; todavia, com o tempo de exposição ao eletrólito, a corrosão passou a ser controlada pela liga 2024. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
52

Dieta de muito baixo valor calórico em obesos mórbidos no período pré-operatório de cirurgia bariátrica: análise da alteração da composição corporal durante perda de peso aguda / Very low-calorie diet in morbidly obese patients in the preoperative bariatric surgery: analysis of change in body composition during acute weight loss

Marcela Pires Serafim 15 June 2016 (has links)
INTRODUÇÃO: A obesidade mórbida é um fator de risco independente para complicações pós-operatórias precoces e uma estratégia para sua prevenção é a redução de peso no período pré-operatório de cirurgia bariátrica através da intervenção nutricional. Assim, a dieta de muito baixo valor calórico (DMBVC) é indicada para obesos mórbidos e controle de suas comorbidades. Além da perda de peso (PP), avaliar a composição corporal é uma necessidade na prática clínica e uma avaliação precisa de cada componente corporal faz-se necessária para complementar o diagnóstico nutricional. OBJETIVO: Analisar a alteração da composição corporal de obesos mórbidos durante a PP aguda no período pré-operatório de cirurgia bariátrica induzida por DMBVC. MÉTODO: Foram avaliados 120 pacientes internados no Hospital das Clínicas da FMUSP. A avaliação da composição corporal foi realizada antes e após a dieta ofertada durante a internação hospitalar e foram analisadas as alterações de peso, IMC, circunferências de pescoço, cintura e quadril, gordura corporal (GC) e massa livre de gordura (MLG), sendo estes obtidos através da bioimpedância. Os dados foram categorizados segundo gênero, idade, IMC e diagnóstico de diabetes. RESULTADOS: O período médio de consumo da DMBVC foi de 8 dias. Os pacientes apresentaram em média 5% de PP representada principalmente por redução de GC (85% da PP). Todas as reduções nas circunferências corporais foram estatisticamente significantes. Todos os pacientes tiveram PP, mas observamos dois comportamentos distintos com relação à alteração da composição corporal que proporcionou a divisão em dois grupos: no grupo A (GA) (63% dos pacientes) houve diminuição de GC e de MLG e no grupo B (GB) houve diminuição de GC, mas um aumento na MLG. A PP e a redução do IMC de ambos os grupos foram semelhantes, porém, a discrepância na alteração de GC e MLG foi estatisticamente significante. Verificou-se maior PP e maior redução de GC nos homens, os idosos apresentaram maior porcentagem de PP e maiores reduções de GC e MLG. Os pacientes com IMC > 50 Kg/m2 tiveram maior PP e maiores reduções de GC e de MLG, porém não foi significante, e não foi encontrada diferença estatística para as alterações nos pacientes diabéticos. Não houve correlação entre as categorias estudadas e os diferentes comportamentos de alteração da composição corporal observados. CONCLUSÃO: A DMBVC pré-operatória determinou uma PP à custa de GC com dois comportamentos distintos em relação à MLG (um grupo com redução e outro com aumento) / BACKGROUND: Morbid obesity is an independent risk factor for early postoperative complications, and one strategy for its prevention is weight loss in the preoperative bariatric surgery through nutritional intervention. Thus, the very low calorie diet (VLCD) is indicated for morbidly obese and its comorbidities control. In addition to the weight loss (WL), assess body composition is need in clinical practice, and an accurate assessment of body composition is necessary to supplement the nutritional diagnosis. AIM: analyze the change in body composition of morbidly obese patients during the acute WL in the preoperative bariatric surgery induced by VLCD. METHODS: We evaluated 120 patients hospitalized at University of São Paulo Clinical Hospital. The assessment of body composition was performed before and after the diet offered during hospitalization, and analyzed changes in weight, BMI, neck, waist and hip circumferences, body fat (BF) and fat free mass (FFM), these obtained by bioimpedance. Data were categorized according to gender, age, BMI and diabetes diagnosis. RESULTS: The average period of VLCD was 8 days. The patients had 5% WL and this was represented principally by BF reduction (85% of WL). All reductions in the body circumferences were statistically significant. All of the patients had WL, but observed two distinct behaviors in relation to the change in body composition which provided the division into two groups: group A (GA) (63% of the patients) had decreased BF and FFM and Group B (GB) had decreased BF, but an increase in the FFM. The WL and the reduction of BMI of both groups were similar, however, the discrepancy in the BF and FFM change was statistically significant. There was a higher WL and greater reduction of BF in men, the elderly had a higher percentage of WL, with a significant difference, and greater reductions of BF and FFM. Patients with BMI > 50 kg/m2 had higher WL and greater reductions of BF and FFM, but it was not significant, and there was no statistical difference changing in diabetic patients. There was no correlation between categories studied and the different behaviors change in the body composition found. CONCLUSION: the preoperative VLCD determined an acute weight loss basically of BF, with two behaviors concerning FFM changing (one group with decreasing and the other with increasing)
53

ModulaÃÃo do retinol na lesÃo da barreira morfofuncional induzida pela toxina A do Clostridium difficile em culturas de cÃlulas intestinais / Retinol modulation protecting the morfofunctional barrier challenged the Clostridium difficile Toxin A in intestinal cell lines

Andressa Aby Farraj Linhares Maciel 27 July 2007 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / A vitamina A (retinol) à um nutriente essencial necessÃrio em pequenas quantidades para o funcionamento normal do sistema visual, funÃÃo imune e reproduÃÃo. Nosso grupo de pesquisa investigou o efeito de altas doses por via oral em crianÃas com diarrÃia em estudos prospectivos em comunidade em Ãreas endÃmicas no Nordeste do Brasil e encontrou benefÃcios terapÃuticos com a utilizaÃÃo do retinol na reduÃÃo da mÃdia de duraÃÃo da diarrÃia, porÃm nÃo houve diminuiÃÃo da incidÃncia de episÃdios diarrÃicos. Esse estudo explorou o papel da suplementaÃÃo do retinol em linhas de cÃlulas intestinais frente ao dano citotÃxico da Toxina A do C. difficile (TxA). O C. difficile à principal patÃgeno causador da diarrÃia associada ao uso de antibiÃticos e da colite pseudomembranosa. Investigou-se alteraÃÃes da resistÃncia elÃtrica transepitelial (TER) em cÃlulas Caco-2, e nos modelos de proliferaÃÃo, migraÃÃo e morte celular em IEC-6, apÃs a injÃria induzida pela TxA. Os resultados mostraram que a suplementaÃÃo do retinol, principalmente no meio sem glutamina, aumentou a TER, migraÃÃo celular, como tambÃm promoveu uma reduÃÃo significativa da apoptose e necrose, porÃm este efeito nÃo foi visto no modelo de proliferaÃÃo celular. Para estudar a modulaÃÃo do retinol na diminuiÃÃo da TER induzida pela TxA, as cÃlulas foram expostas a TxA (0,1&#956;g/mL) durante 24h. O retinol aumentou a TER (% do valor inIcial) nas concentraÃÃes de 0,1 e 0,3nM Ãs 3h (59,3Â1,3; 69,8Â0,6vs 59,3Â1,3&#937;cm2,respectivamente), e Ãs 4h (36,1Â0,02; 33,5Â1,8 vs 27,3Â0,2&#937;cm2,respectivamente) em relaÃÃo ao controle sem retinol e com TxA. Nesses intervalos de tempo nÃo houve influÃncia da proliferaÃÃo celular nas cÃlulas Caco-2. O retinol aumentou a proliferaÃÃo celular na lesÃo induzida pela TxA (0,1&#956;g/mL) em 14,2; 23,8; 59,8; 8,4; 30,2; 44,1% (0,01; 0,03; 0,1; 1,0; 10; 100nM de retinol, respectivamente), apÃs 24h comparado com controle com TxA. Depois de 12 e 24h de exposiÃÃo a TxA (0,01&#956;g/mL), seguido do arranhÃo na monocamada da cÃlulas IEC-6, a suplementaÃÃo do retinol aumentou significantemente a migraÃÃo nas concentraÃÃes de 0,1-100nM em uma taxa de 30-80% e 60-100%, nas 12h e 24h, respectivamente. O retinol reduziu a apoptose e a necrose induzida pela TxA nas concentraÃÃes de 0,03-100nM, em comparaÃÃo com controle com a TxA. Os resultados sugerem que o retinol exerce um importante papel na reduÃÃo da apoptose, em aumentar a migraÃÃo e proliferaÃÃo e em prevenir a reduÃÃo da TER, na lesÃo pela TxA, sugerindo que a vitamina A à um nutriente essencial na proteÃÃo na barreira funcional epitelial / Vitamin A (retinol) is an essential nutrient that is necessary in small amounts for normal functioning of the visual system, immune function and reproduction. Our group has investigated the effect of oral dosis of vitamin A on the early childhood diarrhea in our prospective community-based studies in high endemic areas in the Northeast of Brazil and has found a benefit of retinol therapy in reducing the mean duration but not the incidence of diarrheal episodes. In this study, we have explored the role of retinol supplementation in intestinal cell lines, following Clostridium difficile toxin A (TxA) cytotoxic challenge. C. difficile is the most common anaerobic pathogen that causes antibiotic-associated diarrhea and pseudomembranous colitis. We have focused on changes in transepithelial electrical resistance (TER) in Caco-2, a more differentiated intestinal cell line, and on models of proliferation, migration and cell death in IEC-6 cells, an undifferentiated crypt cell line, following or not by TxA-induced cell injury. The results showed retinol alone increased the TER, cell migration and proliferation, and also promoved significant reduction of apoptosis and necrosis, however this effect was not observed at the cell proliferation. To study the retinol effect on the TxA-induced loss of TER, cells were exposed during 24h to 0,1&#956;g/mL TxA. Retinol improved TER (% of initial value) at the concentrations of 0,1nM and 0,3nM at 3h (59,3Â1,3; 69,8Â0,6 vs 59,3Â1,3&#937;cm2, respectively), and at 4h (36,1 0,02; 33,5 1,8 vs 27,3Â0,2&#937;cm2, respectively) in relation to the untreated control challenged with TxA. During this time there was no influence of the cell proliferation in the Caco-2 cells. Retinol increased cell proliferation after TxA-induced cell damage (0,1&#956;g/mL) at a rate of 14,2%, 23,8%, 59,8%; 8,4%; 30,2%; 44,1% after 24h (doses of 0,01; 0,03; 0,1; 1,0; 10; 100nM of retinol, respectively), compared to controls only with TxA. After 24h of TxA exposure (0,01&#956;g/ml), following plate scraping, the retinol supplementation improved significantly IEC-6 migration at the concentrations of 0,1-100nM in rate of 30-80% and 60-100%, in 12h and 24h, respectively. Retinol reduced TxA-induced apoptosis and necrosis at the concentration of 0,03: 0,1; 1; 10 and 100nM, p<0.05, in comparison to the control with TxA. These results suggest that retinol has a critical role in reducing apoptosis, improving cell migration and proliferation and preventing the reduction in TER, following TxA challenge, suggesting that vitamin A is an essential nutrient to protect the intestinal epithelial barrier function
54

Detecção da abertura e colapso alveolar durante o ciclo ventilatório através da tomografia de impedância elétrica / Tidal recruitment detection by Electrical Impedance Tomography in an experimental model

Raquel Belmino de Souza 25 November 2011 (has links)
Introdução: A Abertura e fechamento alveolar a cada ciclo respiratório (TR) é mecanismo de lesão pulmonar associada à ventilação mecânica. É frequente, especialmente em pacientes com lesão pulmonar aguda/ sindrome do desconforto respiratório agudo, mas pode ocorrer em pulmões normais, devido à pressão expiratória final positiva (PEEP) insuficiente. A fração inspirada de oxigênio (FiO2) também pode ter um papel na modulação da lesão pulmonar: frações mais baixas, em situação de relação ventilação perfusão (V/Q) crítica, podem retardar o colapso alveolar. A Tomografia de Impedância Elétrica (TIE) é uma nova ferramenta de imagem não invasiva, à beira do leito, que reconstrói imagens transversas da resistividade dos tecidos torácicos, obtidas a partir de uma corrente elétrica injetada por eletrodos colocados circunferencialmente no tórax. Atualmente, o padrão ouro de detecção de TR é a tomografia computadorizada (TC), que utiliza radiação, transporte de pacientes para sua execução, exigindo manobras que podem ocasionar a instabilização dos pacientes. Hipótese deste estudo: é possível detectar e quantificar a ocorrência de TR com TIE. Métodos: 7 suinos traqueostomizados, sob sedação, bloqueio neuromuscular e ventilação mecânica, foram submetidos a manobra de recrutamento alveolar (MRA) em pressão controlada, com pressão platô=50 cmH2O, PEEP=35 cmH2O, aplicada por 2 minutos. Seguiu-se ventilação com volume controlado, posição supina, volume corrente (VT) = 10 ml/kg, fluxo 10l/min FR=10irpm, FiO2=100% e PEEP decremental (20-10-3cmH2O), em passos de 10 minutos. Ao final de cada passo, os animais foram submetidos a uma pressão positiva contínua sobre as vias aéreas em dois níveis, quando se procedeu à TC: pressão de platô (representando inspiração) e PEEP (expiração). Imagens de TIE foram adquiridas continuamente. Os animais foram submetidos à nova MRA, repetindo-se o protocolo em FiO2=40%. Após lesão pulmonar (lavagem pulmonar com SF 0,9% até atingir SpO2< 95%), os passos acima foram repetidos. Para detecção de TR pela TIE, dois métodos foram testados, um método original proposto por este estudo, baseado nas variações de complacência regional (pixel a pixel) ao longo do volume corrente (Método1) e um método descrito em estudo recente por Putensen et al. (Método2). Ambos foram comparados à TC. Resultados: Ocorreu colapso progressivo durante PEEP decremental, sempre maior na FiO2=100% (versus 40%) e após lesão (versus pré-lesão) para as PEEPs correspondentes. A análise de regressão linear, Métodos 1 e 2 para TR em relação à TC evidenciou; Método 1 - R²=0,578 e Método 2 - R²=0,409. As correlações foram melhores quando se considerou apenas as medidas a 100%: R²=0,756 (Método 1) e R2=0,646 (Método 2). Curva ROC; Método 1- área sob a curva: 0,86 e Método2 - 0,79. Regressão logística; Método1 superior ao Método2. Pela ANOVA avaliamos PEEP, lesão, FiO2 e P.Platô na detecção de TR pela TC e Método1..A principal difrerença foi não haver influência da FiO2 sobre TR, Método1 Conclusão: O Método 1 foi superior ao Método2 na detecção de TR, com sensibilidade e especificidade suficiente para se avaliar a utilização clínica. A detecção de TR pelo Método1, não foi influenciada pela FiO2, ao contrário da TC. Estes achados foram compatíveis com os resultados de mecânica pulmonar ( pressão de platô). Portanto, o Método1 foi mais sensível que a TC, pois foi capaz de detectar TR mesmo em situações de ventilação pouco acima do V/Q crítico nas situações de FiO2 de 40%, ao contrário da TC. A TIE não sofreu alterações como o efeito de volume parcial como a TC / Introduction: Cyclic opening and closure of alveolar units during the respiratory cycle, or tidal recruitment (TR), is a harmful mechanism of ventilation induced lung injury. It is frequent, especially in acute lung injury and acute respiratory distress syndrome patients, but can occur in normal lungs under mechanical ventilation, because of an insufficient PEEP. Oxygen concentration (FiO2) can modulate collapse and low FiO2 can delay it. Electrical Impedance tomography (EIT) is a noninvasive imaging tool that reconstructs a cross-sectional image of lungs regional resistivity using electrodes placed around the thorax. EIT is a useful imaging tool for regional ventilation monitoring, as proved by many studies. We hypothesized that is possible to detect and quantify the occurrence of TR by EIT. Seven pigs tracheostomized, sedated and using neuromuscular blockade were submitted to mechanical ventilation. A recruitment maneuver (RM) using plateau pressure = 50cmH2O and positive end expiratory pressure (PEEP) = 35cmH2O for 2 minutes was applied. After, animals were ventilated in volume controlled ventilation mode (VCV), with a tidal volume (Vt) =10ml/kg, inspiratory flow=10l/min, respiratory frequency=10irpm, FiO2=100%. Decremental PEEP (20-10-3cmH2O) steps were applied with 10 minutes intervals between them. Thoracic computed tomography (CT) images were done with a continuous positive airway pressure (CPAP) = Plateau pressure achieved in VCV and PEEP applied, simulating an inspiration and expiration respectively. EIT was acquired continuously during the protocol. RM was repeated and then protocol was repeated, using FiO2=40%. Lung injury was induced (with lung lavage - SF 0.9% until SpO2< 95%). After protocol was repeated including both FiO2. Two TR detectors were tested; an original imaging tool created by our group (Method 1) and a second imaging tool created in a recent study by Putensen. (Method 2). Both methods were compared to CT. Results: A progressive alveolar collapse during decremental PEEP was observed, always greater with FiO2=100% (versus FiO2=40%) and after lung injury (versus before lung injury). Linear regression analysis for Methods 1 and 2 showed for Method1 R2=0.578 and Method 2 R2=0,409. Correlations were better when FiO2=100% was considered individually; Method1 - R²=0,756 and Method2 - R²=0,646. ROC curve presented an area under the curve better for Method1 (0,86) related to Method2 (0,79). Logistic regression also showed better result for Method1. ANOVA was used to test influence of variables as PEEP, lung lesion, FiO2 and Plateau pressure on tidal recruitment. Method1 and CT were tested. The main difference between them was that Method 1 was not influenced by FiO2. Conclusion: Method 1 was superior than 2 for TR detection with sufficient specificity and sensibility for a trial on clinical application. Tidal recruitment detection by Method1 was not influenced by FiO2, but it was for CT, what was supported by results of lung mechanic (plateau pressure). Under lower FiO2 (40%) occurred an underestimation of TR by CT, once the change in ventilation occurs even in lower FiO2 which is not detected by CT. CT is also influenced by partial volume effect, what didn´t occurred with EIT
55

Estudo de processos de transporte eletrônico em dispositivos a base de semicondutores orgânicos / Investigation of electronic transport processes in organic semiconductor based devices

Fernando Araújo de Castro 25 March 2004 (has links)
O objetivo deste trabalho foi de estudar processos de transporte eletrônico em dispositivos a base de semicondutores orgânicos através de técnicas avançadas, como ressonância magnética detectada eletricamente (RMDE) e espectroscopia de impedância elétrica em corrente alternada. Além destas, medidas de ressonância paramagnética eletrônica (RPE) convencional também foram realizadas de forma a complementar as medidas de RMDE. Os dispositivos e materiais estudados foram: (hole-only e PLED) de MEH-PPV, polianilina e OLED multicamadas de Alq3 e -NPD. A técnica de RMDE mede a variação de condutividade da amostra na condição de ressonância magnética, permitindo relacionar processos microscópicos com os seus efeitos nos processos de transporte eletrônico. Os estudos de RPE e RMDE em polianilina mostraram uma transição entre os tipos de spin observados em função da temperatura. Os resultados obtidos indicam que o sinal de RPE se deve principalmente a estados de superfície, enquanto a técnica de RMDE permite observarmos também estados do volume, dependendo da forma de preparação dos dispositivos e dos parâmetros utilizados nas medidas. O sinal de RMDE foi atribuído ao hopping de pólarons intercadeias poliméricas. Nos dispositivos de MEH-PPV, o sinal de RMDE apresenta duas componentes, uma foi atribuída à fusão de pólarons negativos para formar bipólarons negativos e a outra foi atribuída à fusão de pólarons positivos. A deficiência na emissão de luz de alguns dos PLEDs estudados foi atribuída ao desbalanceamento de injeção de cargas, que pode ser observado pela diferença de intensidade entre as componentes do sinal. Nos OLEDs a base de Alq3, medidas de espectroscopia de impedância elétrica em função da voltagem dc (Vdc) mostraram um acúmulo de cargas nas interfaces internas do dispositivo, em baixas tensões. Entretanto, para valores mais altos de Vdc, quando começa o processo de recombinação, foi observado um fenômeno pouco estudado na literatura, conhecido como capacitância negativa. Possíveis abordagens a este problema foram propostas / The subject of this work is the investigation of electronic transport processes in organic semiconductors based devices using advanced techniques, such as electrically detected magnetic resonance (EDMR) and ac electrical impedance spectroscopy. Electron Paramagnetic Resonance (EPR) measurements were also carried out to complement the EDMR results. The studied devices and materials were: MEH-PPV hole-only devices and PLEDs, polyaniline and multilayer Alq3 and -NPD based OLEDs. EDMR measures the sample conductivity variation during magnetic resonance condition, which allows relating microscopic processes to its effects on electronic transport processes. EPR and EDMR investigations on polyaniline showed a transition between two kinds of observed spins as a function of temperature. The results indicate that EPR probes especially surface paramagnetic states, while EDMR allows observing both surface and bulk paramagnetic states, depending on how devices are prepared and on some measurement parameters. The EDMR signal was assigned to interchain hopping of pólarons. On MEH-PPV devices, the EDMR signal was composed of two lines, one was attributed to negative pólarons fusion to form negative bipólarons and the other was assigned to positive pólarons fusion. The light emitting deficiency presented by some of the PLEDs investigated was assigned to a misbalanced charge injection, what could be observed by the difference between the intensity of the two components. Impedance spectroscopy measurements on Alq3 based OLEDs as a function of the dc voltage (Vdc) showed charge accumulation at the inner interfaces of the device at low Vdc values. However, at higher Vdc values, when recombination starts to take place, a strange phenomenon, usually called negative capacitance, was observed. Possible approaches were proposed
56

Avaliação da correlação entre a tomografia de impedância elétrica e o volume corrente aplicado durante o suporte ventilatório mecânico invasivo / Evaluation of the correlation between electrical impedance tomography and tidal volume applied during mechanical invasive ventilatory support

Hirota, Adriana Sayuri 12 December 2018 (has links)
Introdução: A tomografia de impedância elétrica (TIE) é uma técnica de imagem não invasiva que mensura o potencial elétrico na superfície torácica através de eletrodos colocados ao redor do tórax. Essas medidas são transformadas em uma imagem bidimensional da distribuição da impedância elétrica no tórax. Esse instrumento detecta modificações da densidade pulmonar e distribuição do volume corrente. Entretanto, é necessário melhor avaliação da sua eficiência em estimar o volume corrente (VT) a cada ciclo ventilatório. O objetivo do estudo é avaliar a correlação do volume estimado pela TIE com o VT aplicado durante o suporte ventilatório mecânico. Métodos: Inicialmente, foram estudados cinco suínos da raça Landrace. Os animais foram sedados, intubados e monitorados com a TIE. Foram aplicados volumes incrementais (100, 250, 500, 750 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 5, 10 e 20 cmH2O, antes e depois da promoção de lesão pulmonar com lavagem com solução salina. Posteriormente, outros cinco animais foram monitorados com a tomografia computadorizada de tórax por raios X (TC) e a TIE. Foram aplicados volumes incrementais (250, 500 e 1000 mL) com a seringa de precisão em ZEEP e com PEEP de 10 e 20 cmH2O, também antes e depois da promoção de lesão pulmonar. A amplitude da variação de impedância mensurada pela TIE foi convertida em volume e foi calculado o volume de ar na TC. Análises de correlação e concordância foram realizadas com o programa \"R\" (© R Foundation for Statistical Computing). Resultados: Em ZEEP, o coeficiente de correlação entre os volumes estimado pela TIE e calculado pela TC foram, respectivamente, 0,90 e 0,96 na comparação com a seringa de precisão. O coeficiente de determinação entre a TIE e a seringa de precisão foi progressivamente reduzindo (0,90; 0,89 e 0,81 com PEEP de 5; 10 e 20, respectivamente) com o aumento do volume pulmonar promovido pela elevação da PEEP. A TC mostrou um deslocamento progressivo do conteúdo aéreo no sentido caudal com o aumento do volume pulmonar. Conclusões: Há uma boa correlação entre o volume estimado pela TIE e o VT aplicado durante o suporte ventilatório mecânico quando utilizados volumes e pressões usuais na prática clínica / Rationale: Electrical impedance tomography (EIT) is a noninvasive imaging tool that reconstructs a cross-sectional image of the lung\'s regional conductivity using electrodes placed circumferentially around the thorax. It is able to detect changes of lung air content and tidal volume (VT) distribution. However, better evaluation of its capacity to quantify VT variations is necessary. The aim of our study was to assess the correlation between volume estimated by EIT and tidal volume applied at different positive end-expiratory pressures (PEEP). Methods: Initially, in an experimental study five mechanically ventilated pigs monitored by EIT were studied. VT increments (100, 250, 500, 750 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 5, 10 and 20 cmH2O before and after lung-injury (induced by saline lavage). Another five pigs was monitored by EIT and x-ray computed tomography (CT). VT increments (250, 500 and 1000 mL) were applied with a calibrated syringe at zero end-expiratory pressure (ZEEP) and PEEP levels of 10 and 20 cmH2O before and after lung-injury. Lung air volume was calculated at CT scan and the amplitude of impedance change measured by EIT was converted to volume (mL). Correlation and agreement analysis was performed at \"R\" program (© R Foundation for Statistical Computing). Results: At ZEEP, volume estimated by EIT and volume calculated at CT obtained r2 = 0.90 and 0.96 respectively, when compared to calibrated syringe. The coefficient of correlation between EIT and calibrated syringe impaired (0.90; 0.89 and 0.81 with PEEP of 5; 10 and 20, respectively) with increase of the lung volume due to increased PEEP. CT showed a progressive displacement of the air content to the caudal thoracic levels with the increase of the lung volume. Conclusion: EIT is able to estimate tidal volume during mechanical ventilatory support when used volumes and pressures usually applied at bedside
57

Índice de adiposidade corporal modificado para determinação de gordura corporal de adultos com obesidade mórbida / Modified Body Adiposity Index to determine body fat in morbid obese adults

Bernhard, Aline Biaseto 14 January 2015 (has links)
INTRODUÇÃO: A obesidade mórbida tornou-se um importante problema de saúde pública. A medida de massa corporal não é capaz de identificar deficiências ou excessos dos diferentes componentes corporais, surgindo a necessidade de se avaliar a composição corporal. Não há consenso sobre o melhor método para esse fim em obesos mórbidos. O Índice de Adiposidade Corporal (IAC) foi proposto para ser um método simples e preciso para uma população de diversificada quantidade de gordura corporal (GC). OBJETIVO: Avaliar a eficácia do IAC em determinar GC de adultos com obesidade mórbida. MÉTODOS: O IAC foi comparado à Bioimpedância (BIA) em 240 adultos obesos mórbidos (Grupo 1= G1), uma equação específica para determinar GC em obesidade mórbida foi desenvolvida e, posteriormente, validada em outra amostra de 158 indivíduos (Grupo 2 = G2). RESULTADOS: Observou-se diferença significativa entre os dois métodos (p=0,039). A quantidade média de GC no G1 foi 52,3±6,1% segundo a BIA e 51,6±8,1% segundo o IAC, com uma diferença de 0,6±5,1% entre os métodos. Algumas variáveis, como gênero, RCQ e gravidade da obesidade confundiram o IAC. Para minimizar esses erros uma equação (Índice de Adiposidade Corporal Modificado = IACM) foi desenvolvida por meio de regressão linear (IACM% = 23,6 + 0,5 x (IAC); somar 2,2 se IMC >= 50kg/m2 e 2,4 se RCQ >= 1,05). A equação foi aplicada no G2 e possibilitou a redução da diferença entre os métodos (1,2±5,9% para 0,4±4,0%) e o fortalecimento da correlação entre eles (0,6 para 0,7). CONCLUSÕES: O IAC apresenta limitações para determinar porcentagem de gordura corporal de obesos mórbidos, já a equação sugerida (IACM) foi eficaz, não se apresentando significativamente diferente da Bioimpedância e corrigindo as limitações anteriormente apresentadas pelo IAC / BACKGROUND: Morbid obesity has become a public health problem. As body mass is not able to identify deficiencies or excesses of body components, the need to assess body composition emerged. There is no consensus of the best method to measure body composition in morbidly obese adults and a simple, accurate, reproducible and inexpensive method is desirable. The Body Adiposity Index (BAI) has been proposed to be a simple and accurate method for a population with a diverse amount of body fat (BF). OBJECTIVE: Evaluate the efficacy of BAI in determining BF of morbid obese adults. METHODS: BAI was compared to bioimpedance (BIA) in 240 morbidly obese adults (Group One= G1) and a specific equation for morbid obesity has been developed to determine BF and then validated on another sample of 158 subjects (Group Two= G2). RESULTS: There was a significant difference between the two methods (p=0,039). The average amount of BF in G1 was 52.3±6.1%, according to BIA and 51.6±8.1% according to BAI, with a difference of 0.6±5.1% between methods. Some variables, such as gender, WHR and severity of obesity mistook BAI. To minimize these errors an equation (Modified Body Adiposity Index = MBAI) was developed by linear regression (MBAI% = 23.6 + 0.5 x (BAI); add 2.2 if BMI >= 50kg/m2 and 2.4 if WHR >= 1.05). The equation was applied to G2 and resulted in a reduction in the difference between methods (1.2±5.9% to 0.4±4.12%) and strengthening of the correlation between them (0.6 to 0.7). CONCLUSIONS: BAI has limitations in determine BF in morbid obesity. The suggested equation (MBAI) was effective for predicting body fat in morbid obese adults; MBAI wasn\'t significant different from BIA and was able to correct BAI limitations
58

Sonographie des Durchmessers der Vena cava inferior und Bioimpedanzanalyse

Dietel, Tobias 03 August 2005 (has links)
Der Wasserhaushalt von Dialysepatienten bewegt sich ondulierend zwischen Überwässerung vor der Behandlung und gezielter Dehydratation nach der Dialyse. Das Ziel der Behandlung ist ein e Flüssigkeitsbalance. Das Gewicht nach der Dialyse bei dem dieser Zustand erreicht ist, wird als Trockengewicht oder Dialysezielgewicht bezeichnet. Zur Zeit ist kein einzelner Parameter verfügbar, von dem sich ein adäquates Trockengewicht der Dialysepatienten ableiten ließe. Die Einschätzung des Trockengewichtes von dialysepflichtigen Kindern stützt sich auf die sorgfältige klinische Untersuchung. Die Bioimpedanzanalyse und die Messung des Durchmessers der Vena cava inferior sind zwei nicht invasive Verfahren, die bereits an erwachsenen Dialysepatienten untersucht und zur Beurteilung des Trockengewichtes sowie des Extrazellulärvolumens angewandt werden. Für Kinder sind keine Referenzwerte für beide Verfahren verfügbar. Aus diesen Grund entschlossen wir uns, Normalwerte für diese Altersgruppe (6,8 bis 16 Jahre) zu erheben. Es zeigte sich ein enger Zusammenhang zwischen Resistanz (BIA) und Durchmesser der Vena cava inferior auf der einen und Werten wie z.B. Alter, Gewicht und Körperoberfläche auf der andren Seite. Resistanz und Durchmesser stehen ebenfalls in enger Beziehung zueinander. Bei der Untersuchung von 31 Dialysepatienten zeigten sich Wachstumsverzögerung und verspätete Pubertät. Daraus wird deutlich das altersbezogene Referenzwerte zu einer falschen Einschätzung des Wasserhaushaltes führen würden. Die kombinierte Anwendung beider Verfahren mit der Körperoberfläche als Bezugswert, kann im Vergleich zu den Veränderungen des Körpergewichtes wertvolle Informationen zur Optimierung des Trockengewichtes geben. / The hydration state of a dialysis patient reflects the balance between fluid overload, normovolemia and underhydration. The goal of the treatment is a fluid balance that is close to normal. The weight after dialysis in which this is achieved is the so called "dry weight". However, there is no single parameter to define the adequate dry body weight of a dialysis patient. In the assessment of dry body weight in dialysis-dependent children one must rely on careful and repeated clinical observation. Bioimpedance analysis and inferior vena cava diameter (IVCD) have been evaluated and utilized in adults as noninvasive parameters for the assessment of dry weight and extracellular volume. Since there are no data available for normal children, we performed a prospective study to establish reference standards for a pediatric population (111 females and 95 males, aged 6.8-16 years). We found strong correlations of both resistance (BIA) and IVCD with age, height, weight, and, in particular, with body surface area. IVCD and resistance also correlated with each other. We also investigated 31 pediatric dialysis patients who showed growth retardation and delayed puberty. Applying age-related reference intervals to pediatric dialysis patients resulted in an underestimation of overhydration. The combination of both methods using body surface area-corrected values with the clinical features of deviation of dry weight will serve as an adjunct to the assessment of post-dialysis dry weight.
59

Papel da tomografia de impedância elétrica em pacientes portadores de hipertensão arterial pulmonar / Electrical impedance tomography in patients with pulmonary arterial hypertension

Hovnanian, Andre Luiz Dresler 27 November 2013 (has links)
INTRODUÇÃO: A hipertensão arterial pulmonar (HAP) é uma doença grave da circulação pulmonar, cuja adequada caracterização ainda depende do cateterismo cardíaco direito. A tomografia de impedância elétrica (TIE) é uma ferramenta de imagem não-invasiva que permite a estimativa a beira-leito da perfusão pulmonar através da medida da variação de impedância durante a sístole (deltaZQ). Embora a busca por métodos não-invasivos que possam descrever a HAP venha crescendo, dados a respeito da aplicação da TIE em pacientes com HAP permanecem escassos. OBJETIVOS: Avaliar a relação entre deltaZQ e perfil hemodinâmico, gravidade e prognóstico de pacientes com HAP. MÉTODOS: Pacientes acompanhados na Unidade de Circulação Pulmonar (InCor-HCFMUSP) e submetidos ao cateterismo cardíaco (por suspeita de HAP ou piora clínica) foram simultaneamente avaliados com a TIE. Foi possível medir deltaZQ por meio de acoplamento eletrocardiográfico. A variação de impedância relativa à ventilação (deltaZV) e a relação deltaZV/deltaZQ também foram analisadas. Com base nos resultados do cateterismo, os pacientes foram divididos em 2 grupos: HAP e aqueles com hemodinâmica normal, nomeados normopressóricos (NP). deltaZQ, deltaZV/deltaZQ e deltaZQ corrigido pelo parâmetro antropométrico peso (deltaZQ*p) foram comparados entre os grupos, correlacionados com parâmetros hemodinâmicos invasivos e analisados como preditores de mortalidade. RESULTADOS: Após o cateterismo, 35 pacientes compuseram o grupo HAP e 8 pacientes, o NP. Os pacientes com HAP apresentaram redução significativa de deltaZQ em comparação aos NP, bem como aumento na relação deltaZV/deltaZQ. Observou-se correlação entre deltaZQ e parâmetros hemodinâmicos, particularmente volume sistólico (VS) (r = 0,66, r2 = 0,43; p < 0,001). O parâmetro peso aumentou a correlação entre deltaZQ e VS (r = 0,77, r2 = 0,59; p < 0,001). Durante o período de estudo, 7 pacientes morreram; eles apresentavam perfil hemodinâmico pior, redução de deltaZQ comparados aos sobreviventes e uma desproporção ainda maior da relação deltaZV/deltaZQ. A sobrevida global em 36 meses foi de 65%. A sobrevida foi menor no grupo de pacientes com deltaZQ*p < 154,6% ou deltaZV/deltaZQ > 12. CONCLUSÕES: A medida de deltaZQ, particularmente corrigida pelo peso, está associada ao perfil hemodinâmico de pacientes com HAP, e sua redução, associada com gravidade de doença e pior prognóstico / BACKGROUND: Pulmonary arterial hypertension (PAH) is a severe disease of the pulmonary circulation, which still relies on the right heart catheterization (RHC) for its accurate characterization. Electrical impedance tomography (EIT) is a non-invasive image tool that allows the bedside estimation of lung perfusion through the measurement of impedance variation during systole (deltaZQ). Although the search for non-invasive methods for evaluation of PAH is developing, data concerning application of EIT in PAH patients remain scant. OBJECTIVES: To evaluate the relationship between deltaZQ and the hemodynamic profile, severity, and prognosis of PAH patients. METHODS: Patients followed at the Pulmonary Circulation Unit (InCor-HCFMUSP) and submitted to RHC (due to the suspicion of PAH or clinical worsening) were simultaneously evaluated by means of EIT. It was possible to measure deltaZQ by producing ECG-gated EIT images. The impedance variation related to ventilation (deltaZV) and the deltaZV/deltaZQ ratio were also analyzed. Based on the results of RHC, patients were discriminated into 2 groups: PAH and those with normal hemodynamics, referred as normo-pressoric (NP) group. deltaZQ, deltaZVdeltaZQ, and deltaZQ corrected by the anthropometric parameter weight (deltaZQ*w) were compared between groups, correlated to hemodynamic parameters, and analyzed as predictors of mortality. RESULTS: After RHC, 35 patients composed the PAH group, and 8 patients, the NP one. PAH patients showed a significant reduction of deltaZQ as compared to NP, as well as an increase of deltaZV/deltaZQ. A significant correlation between deltaZQ and hemodynamic parameters was found, particularly with stroke volume (SV) (r = 0.66, R2 = 0.43; p < 0.001). Weight correction increased the correlation between deltaZQ and SV (r = 0.77, R2 = 0.59; p < 0.001). During the study period, 7 patients died; they presented a worse hemodynamic profile, reduction of deltaZQ compared to PAH survivors, and an even higher deltaZV/deltaZQ ratio. The overall survival at 36 months was 65%. Patients with deltaZQ*w < 154.6 Kg.% or deltaZV/deltaZQ >12 presented worse survival. CONCLUSIONS: deltaZQ, particularly corrected by weight, is associated with hemodynamic status of PAH patients and its reduction is associated with disease severity and worse prognosis
60

Quantificação à beira do leito do potencial de recrutamento alveolar através da tomografia de impedância elétrica em modelo experimental síndrome do desconforto respiratório agudo / Bedside quantification of alveolar recruitment potential using electrical impedance tomography in an experimental model of acute respiratory distress syndrome

Santiago, Roberta Ribeiro de Santis 19 January 2016 (has links)
Introdução: A síndrome do desconforto respiratório agudo (SDRA) tem como parte do seu tratamento uma ventilação mecânica adequada. A manobra de recrutamento alveolar (MRA) faz parte de um grupo de estratégias empregadas nos quadros moderados e graves. A MRA consiste na aplicação de um aumento de pressão transitório e controlado nas vias aéreas no intuito de abrir alvéolos previamente colapsados. A Tomografia de Impedância Elétrica (TIE) é capaz de avaliar o potencial de recrutamento alveolar (PRA) a beira leito. Objetivos:1) Comparar o PRA calculado pela TIE (através do ganho de complacência regional) com a TC. 2) Avaliar o \"deslocamento vertical de volume\" como índice de recrutamento alveolar.3) Estimar precocemente o PRA, através das manobras de recrutamento de rastreio propostas, utilizando a TIE. Método: Avaliamos o PRA em um modelo experimental de SDRA. Utilizamos 15 suínos da raça Landrace. Os animais foram sedados e intubados, em seguida, submetidos ao modelo experimental de SDRA desenvolvido na Faculdade de Medicina da Universidade de São Paulo (LIM-09). Ao término da lesão, um grupo de 7 animais recebeu uma sequência randomizada de manobras de recrutamento de rastreio propostas (Pressões inspiratórias de 30, 35 e 40 cmH2O) seguidas da manobra de recrutamento máxima (Pressão inspiratória de 60 cmH2O). Os animais foram monitorados com TIE e Tomografia computadorizada por raio X (TC) durante todas as manobras de recrutamento. Outro grupo de 8 animais ,submetidos a mesma lesão e com medidas de TC e TIE, foi retirado do banco de dados do LIM-09 e também analisados. Utilizamos o programa IBM® SPSS® Statistics 9.0 e 20.0.Resultados:1) PRA calculado pela TIE atráves do ganho de complacência regional corrigido para hiperdistensão, comparado com TC, apresentou um R2=0,76. 2) PRA calculado pelo ganho de complacência regional corrigido para hiperdistensão combinado com o deslocamento vertical apresentou R2 = 0,91 comparado a TC .3) As manobras de rastreio não conseguiram predizer quantitativamente o PRA mas auxiliariam na correção da hiperdistensão. Conclusões: A TIE é capaz de avaliar o recrutamento alveolar a beira leito. O deslocamento vertical combinado com o ganho de complacência regional corrigida para hiperdistensão representam de forma semelhante a TC o comportamento pulmonar durante uma MRA. A aplicação de uma manobra de recrutamento de rastreio pode ser útil para uma manobra de recrutamento máxima mais segura / Introduction: The acute respiratory distress syndrome (ARDS) treatment demands a proper mechanical ventilation strategy. The alveolar recruitment maneuver (ARM) is an intervention applied in moderate and severe cases of ARDS. ARM is a transitory and controlled increase in mechanical ventilator pressure delivered to the lungs aiming to open previously collapsed alveoli. The electrical impedance tomography (EIT) is a valuable tool at bedside; it is able to monitor and to help during an ARM performance through the estimation of the alveolar recruitment potential (ARP). Objectives: 1) To compare the ARP with the EIT as a regional compliance improvement quantification adjusted for lung hyperdistention with CT. 2) To evaluate the \"volume vertical displacement\" at the same pressure as alveolar recruitment index using EIT and CT. 3) To estimate earlier the ARP using the EIT through a screening recruitment maneuver. Methods: We evaluated the ARP in an experimental model of ARDS. We studied 15 Landrace race pigs. Subjects were sedated, intubated and submitted to the ARDS experimental model developed at Medical investigation laboratory n ° 09, University of São Paulo. In the end of the lung injury, a group of 7 pigs received a randomized sequence of screening recruitment maneuvers (inspiratory pressures of 30, 35 and 40 cmH2O) followed by a maximum recruitment maneuver (inspiratory pressure of 60 cmH2O).EIT and x-ray computed tomography (CT) monitored the steps of each recruitment maneuver. Another group of 8 pigs, submitted to the same lesion and with measures of EIT and CT, were extracted from our data bank. Analysis was performed at IBM® SPSS® Statistics 20.0. Results: 1) ARP calculated by EIT (regional compliance improvement quantification) reached a R2=0,76 when compared to CT. 2) The combination of regional compliance improvement and volume vertical displacement obtained R2 = 0,91 when compared to CT 3) The screening recruitment maneuvers were not able to predict quantitatively the ARP, but they helped in the lung hyperdistension adjustment. Conclusions: EIT is able to evaluate the ARP at bedside. The combination of regional compliance improvement and volume vertical displacement give information similar to CT about the lung behavior during a ARM. The application of a recruitment screening maneuver might be useful for more safe ARM

Page generated in 0.3832 seconds