• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 93
  • 11
  • 2
  • Tagged with
  • 106
  • 106
  • 95
  • 67
  • 45
  • 42
  • 41
  • 32
  • 26
  • 20
  • 17
  • 17
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Análise não linear geométrica de sólidos elásticos tridimensionais reforçados com fibras através do método dos elementos finitos / Geometric nonlinear analysis of fiber reinforced tridimensional elastic solids using finite element method

Pereira, David de Paulo 14 December 2015 (has links)
O presente trabalho tem por finalidade estudar e implementar um modelo numérico de análises cinemáticas de sólidos tridimensionais via método dos elementos finitos posicionais, com consideração de fibras longas ou curtas inseridas de maneira aleatória ou não no domínio da análise. O modelo numérico considera material isotrópico para a matriz e não linearidade geométrica. O domínio do sólido é discretizado por meio de elementos finitos tetraédricos de ordem qualquer, cujos parâmetros nodais são suas posições. A medida de deformação utilizada é a de Green, associada à lei constitutiva de Saint-Venant-Kirchhoff, referenciada pela configuração inicial do corpo, caracterizando o sistema de espaço como Lagrangiano total. O cálculo da posição de equilíbrio é baseado no princípio da mínima energia potencial total. Para a resolução do problema não linear geométrico, adota-se o método iterativo de Newton-Raphson. A inserção das fibras no domínio da análise é feita com a associação das mesmas com elementos finitos unidimensionais curvos de ordem qualquer, cujas posições nodais são dadas em função das posições dos nós dos elementos de sólido. Essa abordagem tem como vantagem o fato de não aumentar o número de graus de liberdade do sistema, ao mesmo tempo em que não limita as posições das fibras dentro do domínio por não ser necessária a coincidência das malhas. Exemplos são apresentados para validação dos desenvolvimentos e implementações realizadas. / This study aims to develop and implement a numerical model of kinematic enrichment, to analyze tridimensional solids based on positional finite element method, considering long and short fibers random distributed inside the domain. The numerical model considers isotropic material and geometric nonlinear behavior for both matrix and fibers. Tetrahedral finite elements with any order of approximation are used to discretize the solid domain, with positions as nodal parameters. Green strain and Saint-Venant-Kirchhoff constitutive law are used, referenced in initial configuration of the body, characterizing the developed formulation as total Lagrangian. The equilibrium is obtained with the application of Total Potential Energy Principle, adopting the Newton-Raphson method to solve the resulting nonlinear system of equations. The fibers are considered in the formulation using curved one-dimensional finite elements with any order of approximation, and the nodal positions of the fibers are related with the nodal positions of the solid elements. The coupling method adopted does not increase the number of degrees of freedom of the system, and does not limit the positions of the fiber nodes to be coincident with solid nodes. Examples are presented in order to validate the developed and implemented formulations.
62

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos /

Verri, Fellippo Ramos. January 2003 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Dalva Cruz Laganá / Banca: Eduardo Passos Rocha / Resumo: A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / Abstract: The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants. / Mestre
63

Restaurações inlays em cerâmicas feldspáticas injetadas em pré-molares: efeito da estratégia de cimentação e da ciclagem mecânica na resistência adesiva entre dentina e restauração

Feitosa, Sabrina Alves [UNESP] 01 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-01Bitstream added on 2014-06-13T18:35:09Z : No. of bitstreams: 1 feitosa_sa_me_sjc.pdf: 1379753 bytes, checksum: 43ae15bd352aa2e18e8da1fc027dae7f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O estudo avaliou o efeito da estratégia de cimentação e da ciclagem mecânica na resistência de união entre dentina e restauração. O tipo de falha dos espécimes foi classificado e a distribuição de tensões foi analisada pela simulação utilizando o método de análise por elementos finitos (MEF). Quarenta e oito (N= 48) pré-molares superiores foram preparados (cavidade tipo MOD) e 48 restaurações inlays de cerâmica feldspática foram obtidas. Os espécimes foram alocadas em 3 grupos, considerando a estratégia de cimentação (N= 16): 1- convencional (Grupos 1 e 2): sistema adesivo condicionamento total de passo único (tratamento da dentina), tratamento da superfície cerâmica com ácido fluorídrico (HF) e silano (S), e cimentação com cimento resinoso; 2- estratégia simplificada (grupos 3 e 4) utilizando o cimento resinoso autoadesivo RelyX U100 (3M) sem tratamento das superfícies da dentina e da cerâmica; 3- estratégia simplificada modificada (grupos 5 e 6) utilizando o cimento resinoso RelyX U100 associado ao tratamento de superfície com HF+S. Os dentes dos grupos 2, 4 e 6 não foram ciclados, enquanto que aqueles dos grupos 1, 3 e 5 foram submetidos a ciclagem mecânica (CM): 2.000.000 pulsos, carga de 100N sobre as cúspides (a restauração não recebeu carga), a 37 oC. Cada espécime foi seccionado de forma seriada para produzir corpos de prova em forma de barras dente-restauração-dente para serem submetidas ao teste de microtração. A região da fratura de cada espécime foi analisada e classificada. A distribuição de tensões em um modelo virtual simulando as condições do estudo in vitro, pelo método de elementos finitos, foi verificada. A Análise de Variância mostrou que: o efeito interação dos fatores não foi estatisticamente significante (a alteração da resistência de união em razão da ciclagem mecânica (CM) para a Estratégia... / The study evaluated the effect of the bonding strategy and mechanical cycling on the bond strength between dentin and inlay restoration. The specimens failure mode and stress distribution (Finite element analysis FEA) was analyzed. Forty-eight (n = 48) pre-molars were prepared (MOD cavity) and 48 feldspathic ceramic inlays restorations were obtained. Specimens (tooth-restoration) were allocated into three groups considering the bonding strategy (n = 16): 1 - Conventional (groups 1 and 2): one-step total etch adhesive system (dentin treatment), hydrofluoric acid (HF) and silane (S) ceramic surface treatment, cementation with resin cement, 2 - Simplified (groups 3 and 4): RelyX U100 (3M) adhesive resin cement without dentin and ceramic surface treatment; 3 - Simplified modified (groups 5 and 6): RelyX U100 associated with HF + surface treatment. Specimens from groups 1, 3 and were subjected to mechanical cycling (CM) - 2,000,000 pulses, 100N on the cusp, 37ºC. Each specimen was sectioned to produce tooth-restoration-tooth bars specimens (cross-sectional area: 1mm2) that were submitted to microtensile bond strength test. The fractured area of each specimen was analyzed. Stress distribution was analyzed by a virtual model simulating the in vitro study by FEA. Variance analysis showed that: factors effect interaction was not statistically significant (there was no statistically differences between strength bond values with CM from groups 1 and 3). Strategy effect was statistically significant (strategy 3 mean strength bond [5.59 MPa] was significantly higher than the strategy 1strength bond [3.44 MPa]). Predominant failure mode was cement-cohesive-type. Von Mises analysis showed stress concentration at cement near the marginal ridge
64

Análise da distribuição das tensões em restaurações cerâmicas sobre dente natural e implante por meio do método dos elementos finitos

Freitas Júnior, Amilcar Chagas [UNESP] 21 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-21Bitstream added on 2014-06-13T19:16:55Z : No. of bitstreams: 1 freitasjunior_ac_me_araca.pdf: 5554830 bytes, checksum: 7d3f07c6ec984117e60fe8bcb23d5364 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / As restaurações cerâmicas têm proporcionado resultados satisfatórios estética e biomecanicamente. Porém, a comparação dos dados sobre a distribuição das tensões nos casos de diferentes restaurações suportadas por dente ou por implante é inconclusiva. O objetivo desse estudo foi avaliar, através da análise de elementos finitos bidimensional, a distribuição interna das tensões nos materiais e estruturas de suporte em função de duas possibilidades restauradoras em cerâmica (faceta laminada e coroa total) e dois tipos de suportes (dente natural e implante). Foram confeccionados 8 (oito) modelos (M) no programa AutoCad 2006, variando o tipo de suporte e restauração: MA (controle) – representação do incisivo central maxilar, hígido, seccionado sagitalmente; MB1, MB2 e MB3 – semelhantes ao MA, restaurados com faceta laminada pelo sistema IPS Empress, IPS Empress Esthetic e Laminado Procera, respectivamente; MC1 e MC2 – semelhantes ao MA, com coroa total pelo sistema IPS Empress 2 (MC1) e Procera AllCeram (MC2); MD1 e MD2 – porção coronária semelhante ao MC1 e MC2, respectivamente, com a presença de um implante osseointegrado (Sistema Bränemark - 4,3 X 15,0 mm) e pilar em zircônia. Para análise numérica (Ansys 10.0), os modelos foram carregados (C) sob duas condições (50N): C1 - 45º de inclinação com o longo eixo dental, no terço médio da face palatina; C2 – perpendicular à borda incisal. Adicionalmente, uma terceira condição foi adotada para o MA: C3 – 50N na borda incisal paralelo ao longo eixo dental. Foram obtidas a tensão equivalente de von Mises (σvM) e a máxima tensão principal em tensão (σmax.t) e compressão (σmax.c). Observou-se que C3 proporcionou a menor variação de svM no dente e estruturas de suporte quando comparada à C1 e C2. / The ceramics restorations have provided excellent aesthetic and biomechanical clinical results. However, the data about the stress distribution in tooth and implant-supported restorations are inconclusive. Using two-dimensional finite element analysis, the purpose of this study was to evaluate the stress distribution in the materials and support structures based on two ceramics restorative possibilities (laminate veneer and ceramic crown) and two support structures (tooth and implant). 8 models (M) were built in the program AutoCAD 2006, varying the restorations and their support structures: MA (control) – an intact maxillary central incisor in sagittal cut; MB1, MB2 and MB3 – similar to MA, with laminate veneers of IPS Empress, IPS Empress Esthetic and Procera veneer, respectively; MC1 and MC2 – similar to MA, with a full crown of IPS Empress 2 (MC1) and Procera AllCeram (MC2); MD1 and MD2 – coronary portion similar to MC, with an osseointegrated implant (Bränemark System - 4.3 X 15.0 mm) and zircon abutment. To the numerical analysis (Ansys 10.0), the following loadings (L) were performed (50N): L1 - on the medium third of the lingual face, in 45º with the dental long axis; L2 – perpendicular to the incisal edge; L3 – 50N in the incisal edge parallel to the tooth long axis (only for the natural tooth). The von Mises equivalent stress (σvM) and maximum principal stress in tension (σmax.t) and compression (σmax.c) were obtained. It was observed that L3 provided the smallest variation of σvM in the tooth and support structures in comparison with L1 and L2. The beam3 elements used for the periodontal ligament modeling showed an appropriate behavior for parallel loading. In the MB and MC, the ceramics increased the σvM in the adhesive interface, mainly for Procera. In the models with implant, the IPS Empress2 showed higher σvM than that for Procera AllCeram.
65

Análise da influência dos sistemas de retenção para overdentures implanto-retidas na distribuição interna das tensões, através do método de elementos finitos

Tabata, Lucas Fernando [UNESP] 05 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-05Bitstream added on 2014-06-13T20:37:56Z : No. of bitstreams: 1 tabata_lf_me_araca.pdf: 8309973 bytes, checksum: 5d726f976a2382ac0dc6e3d5eff78d89 (MD5) / Universidade Estadual Paulista (UNESP) / No tratamento com overdentures o mecanismo de transmissão e distribuição das tensões geradas por cargas funcionais através dos sistemas de retenção e implantes ao osso não está bem documentado. A intensidade e a forma como esta tensão é transmitida e distribuída ao osso determina os locais e a amplitude da reabsorção óssea. O objetivo deste estudo foi analisar, através do Método de Elementos Finitos (MEF) bidimensional, as tensões geradas pelas overdentures e transmitidas aos sistemas de retenção, implantes e tecido ósseo adjacente. Foram construídos em computador, através do programa AutoCAD, três modelos matemáticos representativos de cortes frontais da mandíbula na região inter-caninos, sendo: modelo A (Controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula, suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula, suporte de overdenture com dois attachments esféricos O'rings em dois implantes isolados. Para análise, foi aplicada carga vertical de 100N em três regiões distintas: nos incisivos centrais inferiores, no canino inferior esquerdo e no primeiro molar inferior esquerdo. Os mapas de tensão evidenciaram as máximas e mínimas tensões e foram agrupados de acordo com as situações clínicas simuladas, para análise dos efeitos dos sistemas de retenção sobre as estruturas de suporte. O modelo A apresentou menores valores de tensão máxima (10,928MPa) que os modelos B (74,244MPa) e C (78,454MPa) em relação aos tecidos de suporte, sendo que os maiores valores foram obtidos no modelo C, na região peri-implantar do osso cortical para os três carregamentos aplicados. Os resultados sugerem a ferulização dos implantes e a utilização do sistema de retenção barra-clipe quando se pretende ter distribuição otimizada de tensões no tratamento com overdentures implanto-retidas. / on treatment with overdenture, the transfer and distribution mechanism of the stress generated by functional loads through retention system and implants to bone it is not well documented, The intensity and the manner how this stress is tranfered and distributed to bone determine the sites and amplitude of bone resorption. The objective of this study was to analyse, through Finite Element Analysis (FEA) bidimensional, the stress generated on overdentures and transfer to retention system, implants and surrounding bone tissue. Three mathematic models were made in computer, through AutoCAD software, representing a frontal mandibular slice of inter-canine... (Complete abstract click electronic access below)
66

Avaliação da influência do diâmetro e comprimento do implante osseointegrado associado à PPR Classe I mandibular pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2003Bitstream added on 2014-06-13T20:37:57Z : No. of bitstreams: 1 verri_fr_me_araca.pdf: 6651997 bytes, checksum: 6bb3237d2e73d295c300ea6f6f9c9014 (MD5) / A influência do diâmetro e do comprimento de implantes osseointegrados em associação com próteses parciais removíveis de extremidade livre (PPRELs) ainda não foi relatada na literatura. Dessa forma, este trabalho visou avaliar a esta influência, utilizando o método dos elementos finitos (MEF) bi-dimensional, associando implantes osseointegrados do sistema Branemark sob a base protética de uma PPREL, funcionando apenas como suporte, e analisando mapas de deslocamento e de tensão de von Mises. Para o estudo foram confeccionados oito modelos representativos de uma hemi-arcada mandibular com a presença apenas dos dentes 33 e 34, com as seguintes características: A - sem PPR; B - com PPR sem implante; C - com PPR e implante de 3,75 x 7,00 mm; D - com PPR e implante de 3,75 x 10,00 mm; E - com PPR e implante de 3,75 x 13,00 mm; F - com PPR e implante de 5,00 x 7,00 mm; G - com PPR e implante de 5,00 x 10,00 mm; H - com PPR e implante de 5,00 x 13,00 mm. As forças aplicadas foram estritamente verticais e de 50 N em cada ponta de cúspide. Pelos resultados notou-se que a presença da PPR sobrecarregou o dente suporte, bem como as demais estruturas de suporte da PPR quando comparadas com o modelo A. A presença do implante diminuiu as tensões, principalmente nas extremidades do rebordo desdentado, quando comparados o modelo B com os modelos que possuíam implantes associados. Tanto o comprimento quanto o diâmetro do implante tenderam a diminuir as tensões à medida que aumentavam suas dimensões. Pelos resultados foi possível concluir que: o modelo B foi o que apresentou a maior tendência a deslocamento; quanto maior o comprimento do implante, menores foram os valores do mapa de deslocamento; o modelo B apresentou níveis de tensão de von Mises superiores ao modelo A; os modelos com implantes associados apresentaram níveis menores de tensão de von Mises que o modelo B nas estruturas de suporte da PPR. / The influence of the diameter and length of osseointegrated implants in association with removable partial prostheses of distal-extension (DERPDs) it was not still reported in the literature. In that way, this study evaluated this influence, associating osseointegrated implants of the Branemark system under the prosthetic base of a DERPD, just working as support, and analyzing displacement and von Mises tension maps, using bi-dimensional finite element analysis (FEA). For this study, eight representative models of a lower hemi-arcade were made with the presence of only the teeth 33 and 34, with the following characteristics: A - without RPD; B - with RPD and without implants; C - with RPD and implant of 3,75 x 7,00 mm; D - with RPD and implant of 3,75 x 10,00 mm; E - with RPD and implant of 3,75 x 13,00 mm; F - with RPD and implant of 5,00 x 7,00 mm; G - with RPD and implant of 5,00 x 10,00 mm; H - with RPD and implant of 5,00 x 13,00 mm. The applied forces were strictly vertical and of 50 N in each edge tip. The results shown that the presence of RPD overloaded the support tooth, as well as the other structures of support of RPD when compared with the model A. The presence of the implants reduced the tensions, mainly in the extremities of the toothless edge, when compared model B with the models that possessed implant associated. So much the length as the diameter of the implants tended to reduce the tensions as increased your dimensions. For the results it was possible to conclude that: the model B was what presented the largest tendency to displacement; as larger the length of the it implants, smaller they were the values of the displacement map; the model B presented levels of von Mises tension superiors to the model A; the models with implant associated presented smaller levels of von Mises tension that the model B in the structures of support of RPD; the increase of the length and of the diameter of the implants.
67

Influência do tipo de conexão protética, do platform-switching e do designe do implante no ambiente biomecânico de implantes imediatos com carga imediata

Pessoa, Roberto Sales e [UNESP] 25 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-25Bitstream added on 2014-06-13T19:43:55Z : No. of bitstreams: 1 pessoa_rs_dr_arafo.pdf: 1780565 bytes, checksum: 78498002897f7571851e27403dd44a72 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo do presente trabalho de pesquisa foi avaliar a influencia do tipo de conexao protetica, do platform-switching, e do design do implante no ambiente biomec.nico de implantes imediatos com carga imediata. Para tanto, um modelo de alveolo de extraçao de um incisivo central superior foi constru.do baseado em tomografia computadorizada. Implantes inseridos no alveolo de extra..o foram avaliados por meio de analises em elementos finitos. Uma Analise de Variancia (α=0.05) foi utilizada para interpretar os dados do pico de deformaçao equivalente no osso, do pico de tens.es equivalentes no parafuso do abutment, do deslocamento relativo osso-implante e do gap do abutment. A maior influ.ncia do tipo de conexao protetica e do platform-switching foi observado na tensao do parafuso e no gap do abutment. Por sua vez, o design do implante afetou consideravelmente as deformaçoes no osso e o deslocamento relativo entre o osso e o implante. Nao obstante, evitar a sobrecarga do implante e garantir uma alta estabilidade inicial sao os fatores mais importantes na previsibilidade de implantes imediatos com carga imediata / The aim of the present research work was to evaluate the influence of different connection type, platform switching and implant designs on the biomechanical environment of immediately placed implants. A CT-based model of an upper central incisor extraction socket was constructed. The immediately placed implants were evaluated by finite element analysis. An Analysis of Variance was used to interpret the data for the peak equivalent strain in the bone, peak Von Mises stress in the abutment screw, bone-to-implant relative displacement and abutment gap. The largest influence of the connection type and platformswitching was seen on the peak equivalent stress in the abutment screw and implant-abutment gap. On contrary, the implant design considerably affects the biomechanical environment of immediately placed implants. However, avoiding implant overloading and ensuring a high implant initial stability are the most important factors for the predictability of implants in this protocol
68

Avaliação do nível de inserção óssea do dente suporte em prótese parcial removível mandibular classe I associada a implante osseointegrado: análise pelo método dos elementos finitos

Verri, Fellippo Ramos [UNESP] 11 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-11Bitstream added on 2014-06-13T19:44:51Z : No. of bitstreams: 1 verri_fr_dr_araca.pdf: 1853726 bytes, checksum: 578403c1602d78c980bb821e076ea43c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A colocação de PPR de extremidade livre no arco inferior é uma das mais complexas dentro da área protética. A associação desta com implantes na região distal tem melhorado biomecanicamente seu funcionamento. Porém, existem poucos estudos a respeito desta associação levando em consideração o nível de inserção óssea do dente suporte. Assim, o objetivo desta pesquisa foi avaliar, por meio do método dos elementos finitos bidimensional, a distribuição de tensão nas estruturas de suporte de uma PPREL, associada a um implante osseointegrado de 10,0 x 3,75 mm (Sistema Branemark), próximo ao dente suporte, com diferentes níveis de inserção óssea (íntegro e 1/2 da raiz) e com diferentes tipos de conexão entre a PPR e o dente suporte (apoio incisal e placa distal). Para o estudo, foram confeccionados 8 modelos mandibulares, de extremo livre, com a presença apenas do dente 33, sendo: MA - PPREL convencional, apoio incisal distal, inserção íntegra; MB - idem ao MA, mas utilizando placa distal; MC - idem ao MA, com implante de 3,75 x 10,0 mm e sistema ERA associado; MD - idem ao MC, mas utilizando placa distal; ME - idem ao MA, mas com perda de inserção de 1/2 da raiz; MF - idem ao MB, mas com perda de inserção de 1/2 da raiz; MG - idem ao MC, mas com perda de inserção de 1/2 da raiz; MH - idem ao MD, mas com perda de inserção de 1/2 da raiz. Com o auxilio do programa ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. Os resultados foram obtidos pelos mapas de deslocamento e de tensão de von Mises e mostraram que o implante favorece a associação da forma descrita, que a placa possibilita um maior alívio e menor deslocamento do dente suporte, e que a perda do periodonto de suporte prejudica o prognóstico da prótese. / The rehabilitation with distal extension RPDA is very complex in the prosthetic area and the association with implants had improving its work biomechanical. However, there is little studies about this type of association and no study about the lost of insertion was encountered by FEA. So, the aim of this study was to evaluate, by FEA 2-D, the tension distribution in support structures of a DERPD associated with a osseointegrated implant of 10,0 x 3,75 mm (Branemark System), near to support tooth, with different levels of bone insertion (no lost and 1/2 of root) and with different type of connection between the DERPD and de support tooth (incisal rest and distal plate). For the study, 8 distal extension mandibular models were made, with the presence of tooth 33, presenting: MA - conventional DERPD, incisal rest, no bone lost; MB - like MA, but with distal plate; MC - like MA, but with implanto of 3,75 x 10,0 mm and ERA system associated; MD - like MC, but with distal plate; ME - like MA, but with bone lost of 1/2 of root; MF - like MB, but with bone lost of 1/2 of root; MG - like MC, but with bone lost of 1/2 of root; MH - like MD, but with bone lost of 1/2 of root. By mean of program of FEA ANSYS 9.0, the models were carried with axial forces of 50 N in each cusp tip. The results were obtained by dislodgement maps and von Mises tension maps and shown that the implant was benefit to association by the study, and the plate decreased the tension and the dislodgement of the support tooth, and the bone lost was prejudicial to prognostic of this type of prosthesis. By this methodology, was possible to conclude that: the introduction of an osseointegrated implant with ERA system used like this study decrease the dislodgement of above structures in all models.
69

Estudo do desajuste angular e vertical em próteses fixas implantossuportadas por meio do MEF-3D

Gomes, Érica Alves [UNESP] 17 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-09-17Bitstream added on 2014-06-13T19:44:52Z : No. of bitstreams: 1 gomes_ea_dr_araca.pdf: 12533208 bytes, checksum: 62db616b630b0f9a9807e6b24297d9e8 (MD5) / Objetivo: A análise pelo método dos elementos finitos tridimensional foi utilizada para avaliar o efeito dos desajustes angular e vertical simulado em próteses fixas implantossuportadas parafusadas de 3 elementos, na resposta biomecânica do tecido ósseo peri-implantar, implantes e componentes protéticos. Material e método: Foram confeccionados 4 modelos tridimensionais, representativos de secção mandibular direita contendo um implante na região de segundo pré-molar (2oPM) e outro na região de segundo molar (2oM) ferulizados por uma prótese metalocerâmica implantossuportada parafusada de 3 elementos, diferenciados pelo tipo de desajuste protético, gerando os grupos: GC (grupo controle) - prótese totalmente adaptada aos implantes, DAU (desajuste angular unilateral) - prótese com desajuste angular unilateral de 100μm na região mesial do 2oM, DVU (desajuste vertical unilateral) - prótese com desajuste vertical unilateral de 100μm na região mesial do 2oM e DVT (desajuste vertical total) - prótese com desajuste vertical de 100μm em toda a plataforma de assentamento da infraestrutura no 2oM. Com a utilização do programa de elementos finitos Ansys® uma força vertical total de 400N foi distribuída em 12 pontos de parada cêntrica, sendo que cada molar recebeu um carregamento total de 150N e o 2oPM de 100N, gerando mapas de tensões. Resultados: Verificou-se que a distribuição e os valores de tensões para o tecido ósseo peri-implantar foram similares para todos os grupos. Os grupos com desajustes alteraram o padrão de distribuição e elevaram a magnitude das tensões em relação ao grupo GC. No grupo DAU os maiores valores de tensões foram observados no corpo do implante e parafuso de retenção. Já nos grupos DVU e DVT elevados valores de tensões foram encontrados na plataforma de assentamento da infraestrutura... / Purpose: The three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in 3-piece implant-supported and screw-retained fixed prostheses on biomechanical response in peri-implant bone tissue, implants and prosthetic components. Material and method: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of second premolar (2°PM) and other in the region of second molar (2°M). The implants were splinted by a 3- piece implant-supported metal ceramic prosthesis and differed according to the type of misfit as represented by the groups: CG (control group) - prosthesis with complete fit to the implants, UAM (unilateral angular misfit) – prosthesis presenting unilateral angular misfit of 100μm in the mesial region of the 2°M, UVM (unilateral vertical misfit) – prosthesis presenting unilateral vertical misfit of 100μm in the mesial region of the 2°M, and TVM (total vertical misfit) – prosthesis presenting total vertical misfit of 100μm in the platform of the framework in the 2°M. A vertical load of 400N was distributed and applied on 12 centric points by the software Ansys®. So, vertical loading of 150N was applied on each molar while vertical load of 100N was applied on the 2°PM. Stress maps were obtained by processing of the finite element software. Results: The stress values and distribution on peri-implant bone tissue were similar for all groups. The groups presenting misfit exhibited different distribution pattern and increased stress magnitude in comparison to the group CG. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework... (Complete abstract click electronic access below)
70

Sistemas adesivos convencional e autocondicionante: análise micromecânica tridimensional da interface dentina-adesivo

Martin Júnior, Manoel [UNESP] 30 October 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-10-30Bitstream added on 2014-06-13T18:46:01Z : No. of bitstreams: 1 martinjunior_m_dr_araca.pdf: 402142 bytes, checksum: ec08401476b3983abaa71ed519f0d4e8 (MD5) / OBJETIVO: Avaliar a distribuição das tensões na interface dentina-adesivo variando o sistema adesivo, convencional e autocondicionante, através do método dos elementos finitos tridimensional. MATERIAL E MÉTODO: Foram elaborados 4 modelos no programa Solidworks 2007, sendo: Mc - representação de um espécime em dentina (41x41x82 μm) restaurado com resina composta (RC), apresentando camada de adesivo, camada híbrida (CH), TAGs, dentina peri-tubular, dentina intertubular parcialmente desmineralizada, dentina intertubular e prolongamento odontoblástico, simulando a formação da CH segundo o sistema adesivo convencional; Mr - idêntico ao Mc, com ramificações laterais do infiltrado do adesivo; Ma – idêntico ao Mc, sem TAGs, e com “smear plug”, simulando o sistema adesivo autocondicionante; Mat – idêntico ao Ma, com TAGs. Os modelos foram considerados isotrópicos, homogêneos e linearmente elásticos e a análise numérica foi realizada no ANSYS Workbench 10.0 para obtenção da máxima tensão principal (MAX) após aplicação de força de tração de 0,03 N perpendicular à superfície da RC. A base de todos os modelos foi fixada nos eixos x, y e z. RESULTADOS: A MAX foi maior para o sistema convencional. A presença da ramificação lateral aumentou a MAX na CH para o sistema convencional. Os TAGs modificaram a distribuição da MAX na camada de adesivo para o sistema autocondicionante. CONCLUSÃO: A CH para o sistema convencional apresentou maior MAX em comparação ao sistema autocondicionante. A presença das ramificações laterais do adesivo aumentaram a tensão na CH para o sistema convencional. / OBJECTIVE: The aim of this study was to evaluate the stress distribution in the hybrid layer varying the adhesive system (total each and self-etching systems) using three-dimensional finite element analysis (FE). METHODS: 4 FE models (M) were developed in Solidworks 2007: Mc - representation of a specimen of dentin (41x41x82 μm) restored with composite resin (RC), showing the adhesive layer, hybrid layer (HL), TAGs, peri-tubular dentin, intertubular dentin in order to simulate simulating the HL according to the total-etch adhesive system; Mr - similar to Mc, with lateral branches of the adhesive; Ma – similar to Mc, without TAGs and showing the smear plug in order to simulate the environment for the self-ethcing adhesive system; Mat – similar to Ma, with TAGs. The models were considered isotropic, homogeneous and linearly elastic and numerical analysis was performed in ANSYS Workbench 10.0 to obtain the maximum principal stress (MAX) after application of a tension force of 0.03N perpendicular to the surface of the RC. The botton of all models was fixed in x, y and z axis. RESULTS: The highest MAX in HL was observed in the total etching system. The lateral branches increased the MAX in HL. The TAGs had a little influence on the stress distribution in self-ethching system. CONCLUSION: The HL for the total-etch system showed MAX higher in comparison with the self-etch system. The presence of TAGs increased the MAX in the HL for the total-etch system.

Page generated in 0.063 seconds