• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 88
  • 6
  • 2
  • Tagged with
  • 96
  • 96
  • 85
  • 67
  • 43
  • 41
  • 32
  • 26
  • 22
  • 20
  • 17
  • 17
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Novas metodologias e formulações para o tratamento de problemas inelásticos com acoplamento MEC/MEF progressivo / New methodologies and formulations for the treatment of inelastic problems with BEM/FEM progressive coupling

Mesquita, Arthur Dias 29 August 2002 (has links)
Novas formulações, técnicas e procedimentos são propostos para o tratamento de problemas inelásticos considerando-se acoplamento progressivo. O procedimento apresenta-se bastante adequado para a consideração de problemas de interação bi e tridimensionais que envolvam modificações na geometria e variações das condições de contorno ao longo do tempo. Este permite a inclusão e retirada de sub-regiões e a consideração de hipóteses especiais para o reforço, de maneira que o mesmo contribua adequadamente para o enrijecimento da estrutura. As formulações viscoelásticas e viscoplásticas são baseadas em uma nova metodologia e proporcionam com simplicidade e elegância resultados estáveis e bastante precisos. As representações viscosas para elementos de contorno são obtidas de duas formas, com o termo viscoso obtido através de integrais de domínio e de contorno. Esta última permite a análise viscoelástica de sólidos discretizando-se apenas o contorno do corpo, apresentando-se mais adequada para o tratamento de meios infinitos ou semi-infinitos. O comportamento plástico é levado em consideração através de algoritmos implícitos associativos e não-associativos, cujas expressões são obtidas de forma fechada, resultando em uma considerável economia computacional e uma melhor precisão na resposta não-linear. / New formulations, techniques and procedures are proposed for the treatment of inelastic problems considering progressive coupling. The procedure is quite adequate for the consideration two and three-dimensional interaction problems which involve modifications in geometry and variations of the boundary conditions along the time. This allows the inclusion and retreat of sub-regions and the consideration of special hypothesis for the reinforcement, contributing appropriately for the stiffness of the structure. The viscoelastic and viscoplastic formulations are based in a new methodology and provide with simplicity and elegance quite stable and precise results. The viscous representations for boundary elements are obtained by two ways, with viscous term obtained though domain and boundary integral. The last one permits viscoelastic analysis of solids discretizing only the body\'s boundary, showing to be more appropriate for the treatment of the infinite or semi-infinite regions. The plastic behaviour is taken into account through associative e nonassociative implicit algorithms, whose expressions are obtained in closed way, resulting in a considerable computational economy and a better precision in the non-linear answer.
32

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

López, Camilo Andrés Villabona 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
33

Análise pelo método dos elementos finitos da distribuição de tensões em componentes protéticos posicionados em implantes com conexão cone morse na região anterior da maxila / Analysis by the finite element method of the stress distribution in prosthetic components placed in implants with morse cone connection in the anterior maxilla

Camilo Andrés Villabona López 02 August 2012 (has links)
O objetivo desse estudo foi avaliar, por meio do método tridimensional dos elementos finitos, a distribuição de tensões na interface osso/implante e implante/pilar em implantes com conexão cone morse, posicionados na região anterior da maxila. A partir de uma reconstrução virtual óssea proveniente de uma tomografia computadorizada, foi simulada uma prótese cantilever (11-21) utilizando componente protético com pescoço de 2,5 mm de altura posicionado sobre implantes de 3,75 mm e 4,0 mm de diâmetro e 8,5 mm e 10 mm de comprimento; e prótese parcial fixa convencional (12-22) com componente protético com pescoço de 1,5 mm posicionado em implantes com 3,75 mm e 3,3 mm de diâmetro e 8,5 mm e 10 mm de comprimento. O ensaio realizado com aplicação de carga de 178 N e inclinação de 45° em relação ao longo eixo do implante na superfície palatina das próteses. A tensão de pico Equivalente Von Mises para ambos os casos clínicos foram localizados em áreas do pescoço dos componentes protéticos, plataforma e pescoço dos implantes e região óssea periimplantar. Na região dos incisivos centrais, o pico mais elevado de tensão Von mises correspondeu ao implante de 3,75 mm x 8,5 mm (370,413 MPa), e o menor ao implante de 4,0 mm x 8,5 mm valor (367, 475 MPa). No osso periimplantar a tensão de pico variou de 53,846 MPa para implante 3,75 mm x 8,5 mm à 47,284 MPa para implante 4,0 mm x 10 mm. Para implantes posicionados na região dos incisivos laterais, o valor mais elevado correspondeu ao implante de 3,3 mm x 8,5 mm (832, 911 MPa), e o menor valor ao implante de 3,75 mm x 8,5 mm (433, 666 MPa). No osso periimplantar a tensão de pico variou de 64,433 MPa, para implante 3,3 mm x 8,5 mm, à 50,277 MPa para implante 3,75 mm x 10 mm. Conclui-se que os valores e áreas de pico de tensão nos componentes protéticos posicionados em implantes com os diferentes comprimentos (8,5 mm e 10 mm) e diâmetros (3,75 mm e 4,0 mm), na região dos incisivos centrais, foram semelhantes. Implantes com mesmo diâmetro, posicionados na região dos incisivos laterais apresentaram valores e áreas de tensão semelhantes no pilar protético e osso periimplantar, independente do comprimento. Implantes com 3,3 mm de diâmetro apresentaram o dobro dos valores que implantes com 3,75 mm. / The aim of this study was to evaluate through the three-dimensional method of the finite elements the stress distribution in the bone / implant interface and implant / abutment on implants with morse cone connection, placed in the anterior maxilla. From a virtual reconstruction of bone from a CT scan, cantilever prosthesis (11-21) was simulated using prosthetic component with neck height of 2.5 mm placed in the implant with 3.75 and 4.0 mm diameter and 8.5 and 10 mm length; and conventional fixed partial denture (12-22) with prosthetic component with neck height of 1.5 mm placed in implants with 3.75 and 3.3mm of diameter and 8.5 mm and 10 mm length. The test performed with application of load of 178 N and inclination of 45 ° to the long axis of the implant in the palatal surface of the prosthesis. The peak stress concentration Equivalent Von Mises for both clinical cases were found in areas of the neck of the prosthetic components, platform and neck implants and peri-implant bone area. In the central incisors region, the highest value stressVon mises corresponded to 8.5 x 3.75 mm implant (370.413 MPa), and the lowest value to 4.0 x 8.5 mm implant (367 , 475 MPa). At the peri-implant bone the stress ranged from 53.846 MPa for 8.5 mm x 3.75 mm implant to 47,284 MPa for 4.0 mm x 10 mm implant. For implants placed in the lateral incisors region, the highest value corresponded to 3.3 x 8.5 mm implant (832 , 911 MPa ), and the lowest value to 3.75 mm x 8.5 mm implant (433, 666 MPa ). At the peri-implant bone the highest value stressVon mises ranged from 64.433 MPa for 3.3 mm x 8.5 mm implant, to 50,277 MPa for 3.75 x 10 mm implant. It follows that the values and peak areas of stress on the prosthetic components placed on implants with different lengths ( 8.5 to 10 mm) and diameter (3.75 and 4.0 mm), in the central incisors area, were similar. Implants with the same diameter, placed in the lateral incisors area showed values and areas of tension similar on the abutment and peri-implant bone area, regardless of the length. Implants with 3.3 mm diameter were twice the values that 3.75 mm implants.
34

Avaliação pelo método dos elementos finitos de cargas axiais aplicadas sobre implantes e componentes protéticos com diversas inclinações

Ferreira, Luciano Pedrin Carvalho [UNESP] 24 April 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-04-24Bitstream added on 2014-06-13T20:37:51Z : No. of bitstreams: 1 ferreira_lpc_me_arafo.pdf: 814817 bytes, checksum: a1d0c7e92cf1ea3e5ea3d8dc8b1d5863 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O stress causado pela mastigação sobre implantes que se encontram muito inclinados, pode levar a tensões indesejáveis, causando até o fracasso da restauração. Este trabalho teve como objetivo apresentar através de simulações computacionais, as concentrações de tensões no implante e osso de suporte quando sua inclinação for maior que 30°. Para avaliação comportamental das tensões no implante/osso circundante, foi desenvolvido um modelo representando o primeiro pré-molar inferior. Foi utilizado o método dos elementos finitos bidimensional. Um modelo simulando um implante hexágono externo (4 mm x 15 mm) foi confeccionado, sofrendo inclinações de 30°, 35° e 40°, com uma carga de 100 N e 350 N, incidindo no sentido vertical. Através do enceramento de um componente ucla, a inclinação da coroa protética foi restabelecida. Os materiais de cobertura selecionados foram: porcelana, cerômero e o metal. No implante sem inclinação (controle), a tensão máxima ficou concentrada no local de aplicação da carga. Para os implantes angulados, as tensões se concentraram no local de aplicação da carga, no osso cortical e no terço cervical e médio do implante, no lado da inclinação, independentemente do material de cobertura utilizado. Com a limitação deste estudo, as cargas verticais são bem aceitas pelos implantes sem inclinação, mas quando angulados, a concentração de stress é muito maior no lado em que ocorre a inclinação. / Tensions caused by mastication on very inclined implants can result in undesirable stresses as well as restoration failures. By means of computational simulations, present the concentrations of stresses on the implant and supporting bone when the inclination is greater than 30°. A model representing the first mandibular premolar was developed to evaluate stress behavior in the surrounding implant/bone, using the bidimensional finite element method. A model simulating an external hexagon implant (4 mm x 15 mm) was made, with 0°, 30°, 35° and 40°, a load of 100 N and 350 N, occurring in the vertical direction. The correct prosthetic crown inclination was reestablished by means of a UCLA component. The selected covering materials were: porcelain, ceromer and metal. In an implant without inclination (control), maximum stress was concentrated in the place of load application and on the middle third of the implant. For angled implants, the stress was concentrated on the side of the inclination, on the cortical bone and on the cervical and medium third of the implant. The covering material had similar behauvior. Within the limitations of this study, the vertical loads were well accepted by the implants without inclination, but when implants were angled, the stress concentration was much greater on the side inclination. The finite element method used to investigate inclined implants in the posterior area of the jaw, indicated that there was higher stress concentration where the inclination was. However, clinical studies are important to evaluate the amount of load necessary for bone reabsorption.
35

Efeito da ausência de passividade no sistema coroa-implante-parafuso de retenção por meio do MEF-2D

Gomes, Érica Alves [UNESP] 12 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-12Bitstream added on 2014-06-13T20:37:55Z : No. of bitstreams: 1 gomes_ea_me_araca.pdf: 1098815 bytes, checksum: 1bafd8a36608b27cf45144d22d87c56d (MD5) / Odonto Mega / Objetivo: avaliar o deslocamento e distribuição interna de tensões do sistema coroa/implante/parafuso de retenção e tecido ósseo adjacente, em função de diferentes níveis de desadaptação angular unilateral, por meio do MEF-2D. Materiais e método: foram confeccionados 4 modelos matemáticos, representativos de coroa metálica conectada a implante por meio de parafuso deretenção, inseridos em tecido ósseo, determinando os 4 grupos estudados: Grupo 1 (controle), coroa completamente adaptada ao implante; Grupo 2, 3 e 4, coroa com desadaptações angulares unilaterais de 50æm, 100æm e 200æm, respectivamente. A partir do programa de elementos finitos Ansys, os modelos receberam carga de 133N, com angulação de 30o e deslocamento de 2mm do longo eixo do implante em lado oposto a desadaptação, sendo analisados os mapas de tensões e deslocamento. Resultados: com o aumento das desadaptações angulares, os mapas de tensões mostraram aumento gradativo das tensões na coroa (1056 N/mm2 a 2326N/mm2) e no parafuso de retenção (909.91 N/mm2 a 987.02N/mm2) e uniformidade na distribuição de tensões no implante e tecido ósseo medular. Quanto ao deslocamento, verificou-se inclinação do conjunto de 0.3101mm (controle) a 0.3179mm no grupo 4, em função do carregamento e das desadaptações. Conclusão: a redução do contato unilateral entre a coroa e o implante levou ao deslocamento de todo conjunto e alteração na distribuição e magnitude das tensões ao longo do sistema, principalmente na região da coroa e parafuso de retenção, sendo que, de modo geral, as desadaptações angulares unilaterais de 100æm e 200æm mostraram maiores valores de tensões em relação ao controle. / Objectives: the aim of this study was to evaluate the displacement and stress inner distribution of the prostheses/implant/abutment screw set and surrounding bone, with prostheses presenting different levels of angular misfit unilateral through FEA-2D. Materials and methods: four mathematic models were made, representing metal prostheses in connection of the implant through abutment screw, inside bone tissue, determining 4 groups: Group 1 (control) prostheses fit on the implant; Groups 2, 3 and 4, prostheses with angular misfit unilateral of 50æm, 100æm and 200æm, respectively. It was applied a load of 133N with 30o angulation and off-axis at 2mm of long axis of the implant in opposite direction of misfit on the models, through finite element program Ansys. Results: with upper of angular misfit, the stress maps showed gradual increased of prostheses stress (1056N/mm2 at 2326N/mm2) and uniform stress distribution in the implant and trabecular bone. About the displacement, observed inclination of the set of 0.3101mm (control) at 0.3179mm in the group 4 due to loading and misfit. Conclusions: the lower of the unilateral contact between prostheses and implant proportionate the displacement of all set and the distribution and magnitude alterations of the stress of all the system, principally in the prostheses and abutment screw regions; as a general rule, the angular misfit unilateral of the 100æm and 200æm showed higher stress values in relation to the control.
36

Análise da influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna das tensões, através do método de elementos finitos bidimensional

Barão, Valentim Adelino Ricardo [UNESP] 18 January 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-18Bitstream added on 2014-06-13T20:18:40Z : No. of bitstreams: 1 barao_var_me_araca.pdf: 2925422 bytes, checksum: 91ac65727dd1aa72a0e59c81f8a2faa1 (MD5) / Os implantes osseointegrados quando submetidos a cargas funcionais transmitem as tensões geradas diretamente ao osso. Dessa forma, muitas falhas na osseointegração estão ligadas ao excesso de carga sobre o implante. No caso de próteses implanto-retidas e muco-suportadas, outro importante fator que pode contribuir para uma maior ou menor incidência de tensões ao nível do implante reside na diferença de resiliência entre a fibromucosa e o implante. No tratamento com overdentures, este mecanismo de transmissão e distribuição não está bem documentado. Dessa forma, o objetivo desse estudo foi analisar, através do Método de Elementos Finitos bidimensional, a influência dos sistemas de retenção para overdentures implanto-retidas e da espessura e resiliência da fibromucosa na distribuição interna de tensões. Foram construídos em computador, através do programa Auto CAD, modelos matemáticos representativos de cortes frontais da mandíbula, sendo modelo A (controle), mandíbula edêntula suporte de prótese total convencional; modelo B, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico; modelo C, mandíbula edêntula suporte de overdenture com dois attachments esféricos do tipo o’ring em dois implantes independentes e modelo D, mandíbula edêntula suporte de overdenture com dois implantes ferulizados por meio de barra e clipe plástico associados a dois attachments esféricos distais do tipo o’ring. Em todos os modelos, a fibromucosa assumiu três características de espessura (1, 3 e 5mm) nas resiliências dura, resiliente e flácida, respectivamente, através da variação do módulo de elasticidade da fibromucosa. Para análise, simulada no programa Ansys, os modelos foram fixados nas laterais direita e esquerda, permitindo deflexão da mandíbula. Foi aplicada... / Implants overload is the main factor responsible for osseointegration loss since functional loads are distributed directly to the bone. In addition, the difference between mucosa and implant mobility influence stress level, mainly in prosthesis supported by implant and mucosa. In overdenture treatments, the mechanisms of stress transmission and distribution induced by attachments system are not completely understood as literature concerning the influence of several biomechanical factors remains inconclusive. Thus, the aim of this study was to evaluate the effect of different mucosa thickness and resilience on stress distribution of implant-retained overdentures with different attachment systems using a two-dimensional Finite Element Analysis (FEA-2D). Representative models of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system; Group C, a model of edentulous mandible supporting an overdenture retained by two unsplinted implants with o’ring system; Group D, a model of edentulous mandible supporting an overdenture retained by two splinted implants connected with bar-clip system associated with two distally o’ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5mm) in the resiliences hard, resilient and soft, respectively, through different mucosa’s Young modulus. Evaluation was performed on Ansys software, with both right and left sides of models fasttened to allow mandibular bending. A vertical load of 100N was applied on lower central incisive teeth, and the principal stress was used as analysis criteria. Overall, group A showed the lowest stress values followed by groups C, D and B both in general stress maps as in the evaluation of... (Complete abstract click electronic access below)
37

[en] COMPARATIVE STUDY OF NUMERICAL METHODS FOR SOLVING THE ELASTICITY EQUATIONS IN TOPOLOGY OPTIMIZATION PROBLEMS / [pt] ESTUDO COMPARATIVO DE MÉTODOS NUMÉRICOS PARA SOLUÇÃO DAS EQUAÇÕES DA ELASTICIDADE EM PROBLEMAS DE OTIMIZAÇÃO TOPOLÓGICA

ANDRÉS JOSÉ RODRÍGUEZ TORRES 07 March 2017 (has links)
[pt] Este trabalho apresenta um estudo comparativo de métodos numéricos para solução das equações da elasticidade em problemas de otimização topológica. Um sistema computacional é desenvolvido em MATLAB para solução de problemas de otimização topológica usando malhas poligonais não estruturadas em domínios bidimensionais arbitrários. Dois métodos numéricos são implementados e comparados com o método dos elementos finitos (FEM) em relação à precisão e à eficiência computacional: o recém proposto Método dos Elementos Virtuais (VEM) e o Método dos Elementos Finitos Suavizados (SFEM). A principal característica que distingue estes métodos do FEM é que as funções de base canônicas não são obtidas de forma explícita. A utilização de projetores locais apropriados permite a extração do componente linear das deformações dos elementos e, por conseguinte, o cálculo da matriz de rigidez se reduz a avaliações de quantidades puramente geométricas. Exemplos numéricos representativos, usando malhas convexas e não convexas, para minimização da flexibilidade são apresentados para ilustrar as potencialidades dos métodos estudados. / [en] This work presents a comparative study of numerical methods for solving the elasticity equations in topology optimization problems. A computational framework is developed in MATLAB for solving topology optimization problems using unstructured polygonal meshes in arbitrary two-dimensional domains. Two numerical methods are implemented and compared with the finite element method (FEM) with respect to accuracy and computational efficiency: the recentlyproposed Virtual Element Method (VEM) and the Smoothed Finite Element Method (SFEM). The key characteristic that distinguish these methods from the FEM is that the canonical basis functions are not computed explicitly. The use of appropriate local projection maps allows the extraction of the linear component of the element deformations and, therefore, the computation of the stiffness matrix is reduced to the evaluation of purely geometric quantities. Representative numerical examples, using convex and non-convex meshes, for compliance minimization are presented to illustrate the capabilities of the methods studied.
38

Análise das tensões nos primeiros pré-molares superior e inferior, em contato, através do método de elementos finitos / Enamel stress distribution in superior and inferior premolars, in contact, through a finit elements study

Alexandre Carvalho Teixeira 22 February 2006 (has links)
As lesões cervicais não cariosas foram, durante muito tempo, atribuídas à abrasão causada pela escovação dental, e/ou por processos erosivos. Teorias biomecânicas consideram a possibilidade de que concentrações de tensões na região cervical, causadas pela flexão de cúspides, poderiam contribuir, associadas a outros fatores clínicos, para o desenvolvimento dessas lesões chamadas de abfração O presente trabalho pretende através do método de elementos finitos, utilizando o programa ANSYS versão 8.1, analisar a distribuição de tensões na região cervical de modelos bidimensionais parametrizados dos primeiros prémolares superior e inferior quando estes são colocados em contatos cêntrico e excêntricos no plano frontal, sob uma carga de 1 N. Para simulação da diminuição da mobilidade do ligamento periodontal sob cargas de impacto, o valor real do seu módulo de elasticidade foi aumentado para o correspondente ao do osso esponjoso e ao do osso cortical. Os resultados permitiram concluir que, de uma maneira geral, nas posições excêntricas, os dentes se flexionam e tensões de tração ocorrem na região cervical oposta ao contato com valores compatíveis para formação das lesões. Na posição cêntrica, as tensões de tração se manifestam mais na região da fossa central de ambos os dentes e na cervical do pré-molar inferior. A simulação da diminuição da mobilidade dentaria sob cargas de impacto reduziu o valor das tensões de tração, em todas as regiões analisadas, na ordem de 33% para o pré-molar superior e 66% para o inferior, mas não alterou seu padrão de distribuição. / Non carious cervical lesions were often attributed to toothbrush abrasion and/or erosive process. Biomechanical theories consider that stress concentration in the cervical area, caused by cuspal flexure, may contribue, associated to other clinical factors for the development of the lesion called abfraction. The aim of this finite element study, using the ANSYS version 8.1, is to analyze the stress distribution in the cervical region of superior and inferior premolars bidimensional models. Contacts in centric and eccentric positions were reproduced under a 1 N load. To simulate tooth mobility reduction under impact loads, the elastic modulus of the periodontal ligament was increased to reach the corresponding ones of the alveolar and cortical bone. The results showed that, in eccentric positions, teeth bend and tensile stress are generated at the cervical region opposed to the contact side, justifying the possibility to initiation of the lesion. In centric position, tensile stress occurred on both teeth at the central fossae and at the buccal cervical area of the inferior premolar. The simulation of tooth mobility reduction under impact loads diminished the tensile stress value, at all of the analyzed positions, in a rate of 33% and 66% respectively to superior and inferior premolars.
39

Avaliação de núcleo metálico fundido, núcleo com fibra de vidro e endocrown em cerâmica: análise comparativa pelo método dos elementos finitos

Rossato, Desirée Mory [UNESP] 23 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-23Bitstream added on 2014-06-13T19:20:24Z : No. of bitstreams: 1 rossato_dm_dr_arafo.pdf: 3020954 bytes, checksum: 1a5b7cd1dca8b24d2c32a870ea1c52b3 (MD5) / Dentes tratados endodonticamente têm uma maior incidência a fraturas, tornando sua restauração um desafio para a Odontologia. Foram selecionados três incisivos centrais superiores humanos os quais foram restaurados com núcleo metálico fundido e coroa de cerâmica IPS emax®Press, núcleo de preenchimento em resina ccomposta associado ao pino de fibra de vidro e coroa de cerâmica IPS emax®Press e endocrown em cerâmica IPS emax®Press. Os dentes foram levados ao teste estático de fratura. Paralelamente foi realizado um modelo virtual de um incisivo central que apresentava características e restaurações representativas dos dentes que foram levados ao teste de fratura. A análise computacional pelo método dos elementos finitos 3D foi realizada. Os resultados obtidos nos dois tipos de análise realizada mostram que a coroa endocrown e o pino de fibra de vidro apresentaram um padrão de fratura que não afetou a estrutura radicular enquanto que o núcleo metálico fundido apresentou um padrão de fratura desfavorável envolvendo a estrutura radicular condenando o dente. Na análise dos elementos finitos obtivemos uma correta previsibilidade de onde as coroas e núcleos poderiam falhar. A análise dos elementos finitos é uma metodologia importante na análise de novas técnicas e novos materiais. / Restoration of endodontically treated teeth is a common problem in restorative dentistry, related to the fractures occurring in such teeth. Three human maxillary central incisor were selected and restaured with metal core and IPS emax®ceramic crown, glass fiber post with composite core and IPS emax®ceramic crown and IPS emax®ceramic endocrown. Static loading test were performed on each specimen until failure. Paralleled a 3D model of a maxillary central incisor is presented. The same characteristics of the real teeth used in the mechanical test were applied. A 3D finite elements analysis was made. The results of both analysis shows that endocrown and fiber post have a pattern of fracture that not involve the root while metal core presents a catastrophic pattern of fracture in the root. The FEM analysis is an important methodology in the development of new materials.
40

Influência da altura da coroa em implantes osseointegrados: estudo pelo método dos elementos finitos tridimensionais

Moraes, Sandra Lúcia Dantas de [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T18:46:01Z : No. of bitstreams: 1 moraes_sld_dr_araca.pdf: 1714349 bytes, checksum: d5ff02883440cb484b8e2bd8528c5f78 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os implantes dentais têm sido usados extensivamente para a reabilitação de edentulismo total e parcial, com próteses fixas ou removíveis. Em detrimento das suas taxas de sucesso e previsibilidade, falhas ocorrem e são associadas a complicações biomecânicas. Entre os fatores biomecânicos podemos destacar uma proporção adequada entre comprimento do implante e superestrutura. Porém, pouco é encontrado sobre a influência da altura da coroa, o alcance do braço de alavanca e, conseqüentemente, a tensão no osso cortical e no osso trabecular. Apesar do aumento no uso de implantes, muito pacientes que necessitam dessa terapia ficam limitados devido à pouca altura óssea. Sistemas disponibilizam no mercado implantes curtos, onde procedimentos cirúrgicos invasivos poderiam ser evitados; nesses implantes, porém, é muito comum uma relação coroa/área implantada invertida. Desenvolveremos este trabalho em dois capítulos. O primeiro irá avaliar a influência de três alturas de coroas pré-estabelecidas, quando associadas a implantes de hexágono externo em todas as suas estruturas associadas. No segundo, avaliaremos a influência das mesmas alturas de coroas, associadas a implantes de hexágono externo e cone - morse, na distribuição das tensões no tecido ósseo. Para a primeira parte do trabalho, foram confeccionados três modelos tridimensionais, com auxilio dos programas de modelagem gráfica SolidWorks 2006 e Rhinoceros 4.0, além do programa InVesalius (CTI, São Paulo, Brasil), utilizado para gerar o modelo ósseo a partir de uma tomografia computadorizada. Cada modelo foi composto por um bloco ósseo, com um implante de 3,75 x 10,00mm (Conexão Sistemas de Prótese, São Paulo), com o tipo de conexão: hexágono externo, utilizando três alturas de coroas (10 mm; 12.5 mm e 15 mm), colocadas na plataforma oclusal (hexágono externo). Após geração... / The dental implants have been widely used for rehabilitation of partial and complete edentulism using fixed and removable prostheses. Despite the success rate and predictability, failures are reported and commonly associated with biomechanical complications. Among the biomechanical factors, an adequate proportion between the implant and superstructure dimensions should be established. However, there is little information about the influence of crown height and lever arm on stress in cortical and trabecular bone. Although the use of implants has increased, many patients are limited by insufficient bone height. Thus, some implant systems developed short implants to avoid invasive surgical procedures. Nevertheless, such implants present an inverted crown/anchored area ratio. The present study will be divided into two chapters. The first one will evaluate the influence of three pre-established crown heights attached to external hexagon implants on all structures. In the second chapter, it will be evaluated the influence of the same crown heights attached to external hexagon and morse taper implants on the stress distribution in bone tissue. Initially, three 3D models were fabricated using the softwares SolidWorks 2006 and Rhinoceros 4.0. The software InVesalius (CTI, Sao Paulo, Brazil) was also used to generate the bone model through a computed tomography. Each model was composed by a bone block with an external hexagon implant (3.75 X 10.0 mm) (Conexao Sistemas de Protese, Sao Paulo) and a crown with different heights (10 mm, 12.5 mm and 15 mm) attached to the implant platform (external hexagon). After generation of the geometries, the models were imported to the software FEMAP 10.0 (Siemens PLM Software Inc., USA) for pre- and post-processing of finite elements to generate the meshes as well as the loading and boundary conditions. Axial load of 200N and oblique load of 100N were ... (Complete abstract click electronic access below)

Page generated in 0.0768 seconds