121 |
Influência da areia artificial oriunda da britagem de rocha granito-gnaisse nas propriedades do concreto convencional no estado fresco e endurecido / The Influence of the deriving artificial sand of the britagem of rock granite-gnaisse in the properties of the conventional concrete in the cool and hardened stateCABRAL, Keillon Oliveira 31 October 2007 (has links)
Made available in DSpace on 2014-07-29T15:03:36Z (GMT). No. of bitstreams: 1
dissertacao keilon engcivil.pdf: 6591572 bytes, checksum: 3bc6e86b8a0a0371340b4ad70a9679b7 (MD5)
Previous issue date: 2007-10-31 / The dissertation is aimed at the study being presented theoretical and
experimental verification of the performance of artificial sand come from
crushing the rock of granite-gneiss in relation to natural sand.
Currently, the sand has artificially low commercial value of the market
and is considered a "some kind of piece of marginal material ", whose purpose
is not defined and remained stored in the courtyards of the quarries, forming
huge piles that cause various environmental impacts. In addition to this, the
traditionalism and the lack of information has led to an unwarranted
mystification of this material.
The methodology used for the tests of the research was based on
standardized tests, which attempt to meet the objectives of the dissertation, in
addition to enhancing the development of techniques to search for alternative
aggregates. This has examined the influence of artificial sand in place of natural
sand, with different proportions, and focuses on quality of the concrete in plastic
and hardened its phases, taking into account the mechanical, elastic, physicalchemical,
environmental and economic.
The work was to characterize the material that composed the
concrete studied. After this phase, were up corpses-of-proof concrete, using 15
(fifteen) different traits, so that the natural sand was gradually replaced by
artificial sand, in proportions of 25%, 50%, 75%, and 100%. For each trait was
quantified its rebate, density, air incorporation, resistance to axial compression,
traction, deformation module, absorption by immersion, alkali-aggregate
reaction and an economic evaluation.
It is considered that the main objective of this research has been fully
achieved, because it was proven the theoretical feasibility of replacing part or
even all, of natural sand by artificial sand in conventional / A dissertação ora apresentada visa o estudo teórico-experimental na
verificação do desempenho da areia artificial oriunda da britagem da rocha de
granito-gnaisse em relação à areia natural.
Atualmente, a areia artificial possui baixo valor comercial de
mercado, sendo considerado um material marginal , cuja destinação não está
definida, permanecendo estocado nos pátios das pedreiras, formando enormes
pilhas que provocam vários impactos ambientais. Somando-se a isto, o
tradicionalismo e a falta de esclarecimentos têm levado a uma mistificação
injustificada deste material.
A metodologia utilizada para a realização dos ensaios da pesquisa
foi baseada em ensaios normalizados, onde se buscou atender aos objetivos
da dissertação, além de alicerçar o desenvolvimento das técnicas de pesquisa
para agregados alternativos. Para tal, foi analisada a influência, da areia
artificial em substituição da areia natural, com diferentes proporções, e avaliouse
qualidade do concreto em suas fases plástica e endurecida, levando-se em
conta os aspectos mecânicos, elásticos, físico-químicos, ambientais e
econômicos.
O trabalho consistiu em caracterizar os materiais que compuseram o
concreto estudado. Após essa fase, foram confeccionados corpos-de-prova de
concreto, utilizando-se 15 (quinze) traços diferentes, de modo que a areia
natural foi gradualmente substituída pela areia artificial, nas proporções de
25%, 50%, 75%, e 100%. Para cada traço foi quantificados o seu abatimento,
massa específica, ar incorporado, resistência à compressão axial, tração,
módulo de deformação, absorção por imersão, reação álcali-agregado e uma
avaliação econômica.
Considera-se que o objetivo principal desta pesquisa foi plenamente
alcançado, uma vez que foi comprovada a viabilidade teórica da substituição
parcial ou até mesmo total, da areia natural pela areia artificial, em concretos
convencionais
|
122 |
Levantamento das manifestações patológicas em fundações e estruturas nas edificações, com até dez anos de idade, executadas no estado de Goiás / Survey of pathologies in foundations and structures in buildings with up to ten years old, executed in the state of GoiásALVES, Jader Rodrigues 27 November 2009 (has links)
Made available in DSpace on 2014-07-29T15:03:39Z (GMT). No. of bitstreams: 1
Dissertacao_Jader Rodrigues Alves_2009.pdf: 7812454 bytes, checksum: 2ad5d54c7d0d307c5638af222817e68c (MD5)
Previous issue date: 2009-11-27 / The main objective of this research is to proceed to the rising of the indexes, to identify the pathologies and to characterize the constructions that presented occurrences of pathological manifestations in foundations and structures in the
constructions executed in the State of Goiás, with age of up to ten years. The researches was classified as documental, considering that, to make possible the accomplishment of the same, the files of Regional Council of Engineering, Architecture and Agronomy of Goiás were analyzed -Crea/GO, with a total sample of 545 reports. It was observed that most of the processes are concerning the last seven years. This Organ was chosen by the fact that all of the technical documents are elaborated by professionals, and, mainly, for
Official Organ to be considered. The Method of the Incidence was adopted as methodology recommended for this study observing that in the reports and decisions, elaborated by Crea-GO doesn't be in the number of occurrences of a same pathology and yes only the incidence of the same. The main conclusions of this research were: the main pathological manifestation was found in the foundations repression with a rate of 37.50% followed by collapse with a rate of 22.50%, both in relation to all the pathologies found in the foundation stage, the main pathological manifestation found in stage structure were the cracks with an index of 32.14% compared to all the pathologies found in stage design, regardless of the number executed and the second structural pathological
manifestation found in step structure was the structural deformation with an index 19.84% as compared to all the pathologies found in stage design, regardless of the structural piece performed, the building of single-family residential use were the same who had diseases with a rate of 47.50%,
followed by residential conference with 35 %, 77.50% of the buildings showed that diseases were carried out by private tutors and, for the buildings surveyed 40% had impairment evaluation of use of buildings facing the diseases occurred
in moderate severity, and the rate for high severity was 5%. The disease occurred in low gravity, 45%, most pathological manifestations of both the foundation and structure, occurred in the first year of age of the building. 52.17% in the foundation and concrete structure in 40% of the buildings
surveyed, 35% caused damage to neighboring buildings, and 53.49% of this damage occurred within the first year after completion of the work, and the buildings with an area of 5001 m² to 10,000 m² which caused the highest
percentage of damage, and the recklessness and incompetence were more technical errors committed by professionals with rates of 32.50% each, followed by neglect of index 22.50 %. / O principal objetivo desta pesquisa é proceder ao levantamento dos índices, identificar as patologias e caracterizar as edificações que apresentaram ocorrências de manifestações patológicas em fundações e estruturas nas
edificações executadas no Estado de Goiás, com idade de até dez anos. Pesquisa essa, classificada como documental, considerando que, para viabilizar a realização da mesma, foram analisados os arquivos do Conselho Regional de Engenharia, Arquitetura e Agronomia de Goiás - Crea/GO, com
uma amostra total de 545 relatórios. Observou-se que a maioria dos processos são referentes aos últimos sete anos. Este Órgão foi escolhido pelo fato de que todos os documentos técnicos são elaborados por profissionais, e,
principalmente, por ser considerado Órgão Oficial. O Método da Incidência foi adotado como metodologia recomendada para este estudo ao observar que nos relatórios e laudos, elaborados pelo Crea-GO não constam o número de
ocorrências de uma mesma patologia e sim somente a incidência da mesma. As principais conclusões desta pesquisa foram: a principal manifestação patológica encontrada nas fundações foi o recalque com um índice de 37,50% seguida de desmoronamento com um índice de 22,50%, ambas em relação à todas as manifestações patológicas encontradas na etapa de fundações; a principal manifestação patológica encontrada na etapa de estrutura foram as fissuras com um índice geral de 32,14% em relação à todas as manifestações
patológicas encontradas na etapa de estrutura, independentemente da peça estrutural executada e a segunda manifestação patológica encontrada na etapa
de estrutura foi a deformação estrutural com um índice de 19,84% em relação à todas as manifestações patológicas encontradas na etapa de estrutura, independentemente da peça estrutural executada; as edificações de uso
residencial unifamiliar foram as que mais apresentaram patologias com um índice de 47,50%, seguidas da residencial coletiva com 35%; 77,50% das edificações que apresentaram patologias, foram executadas por profissionais autônomos; em relação às edificações pesquisadas 40% tiveram a avaliação
do comprometimento de uso das edificações frente às patologias ocorridas de gravidade moderada, sendo que o índice para alta gravidade foi de 5%. A maior ocorrência foi a de baixa gravidade com 45%; a maioria das manifestações patológicas, tanto da fundação quanto da estrutura, ocorreram no primeiro ano de idade da edificação. Na fundação 52,17% e na estrutura de concreto armado em 40%; das construções pesquisadas, 35% causaram danos
nas edificações vizinhas, sendo que 53,49% destes danos ocorreram até o primeiro ano após a conclusão da obra, sendo que as construções com área entre 5001 m² a 10000 m² foram as que causaram o maior percentual de danos; e a imprudência e a imperícia foram os erros técnicos mais cometidos por profissionais com índices de 32,50% cada um, seguidos da negligência com índice de 22,50%.
|
123 |
Estudo e avaliação de uma proposta de modelagem do comportamento micromecânico do concreto / Study and evaluation of a modeling proposal to micromechanical behavior to concreteBorges, Dannilo Carvalho 19 August 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-01-07T16:28:03Z
No. of bitstreams: 2
Dissertação - Dannilo Carvalho Borges - 2015.pdf: 3073251 bytes, checksum: 5efdd805f96baaf801696402a7ed039b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-08T11:35:34Z (GMT) No. of bitstreams: 2
Dissertação - Dannilo Carvalho Borges - 2015.pdf: 3073251 bytes, checksum: 5efdd805f96baaf801696402a7ed039b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-08T11:35:34Z (GMT). No. of bitstreams: 2
Dissertação - Dannilo Carvalho Borges - 2015.pdf: 3073251 bytes, checksum: 5efdd805f96baaf801696402a7ed039b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-08-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work deals with a proposed numerical modeling of mechanical behavior in brittle heterogeneous
materials, such as concrete. For this propose, a two-dimensional meso-scale model is presented. The
material is considered as a three-phase material consisting of interface zone, matrix and inclusions – each
constituent modeled by an appropriate constitutive model. The Representative Volume Element (RVE)
consists of inclusions idealized as circular shapes randomly placed into the RVE. The interface zone is
modeled by means of cohesive contact finite elements the inclusions are considered as linear elastic media
and matrix region is considered as elastoplastic material. The main goal here is to show that simple
constitutive modeling of the microstructure can be employed with a computational homogenization-based
approach as an alternative to complex macroscopic constitutive models for the mechanical behavior of the
heterogeneous materials using a finite element procedure within a purely kinematical multi-scale
framework. A set of numerical examples, involving the microcracking and plasticity processes, is provided
in order to illustrate the qualitative performance of the proposed modeling. / Este trabalho apresenta uma proposta para a modelagem numérica do comportamento mecânico da
microestrutura de materiais heterogêneos e frágeis, tal como o concreto. Para este fim, apresenta-se um
modelo 2D de escala mesoscópica. O material é considerado como composto por três fases consistindo de
zona de interface, matriz e inclusões, onde cada constituinte é modelado adequadamente. O Elemento de
Volume Representativo (EVR) consiste de inclusões idealizadas de forma circular aleatoriamente
dispostas no EVR. A zona de interface é modelada por meio de elementos finitos coesivos e de contato e
as inclusões são modeladas como meio elástico linear. Já a matriz é considerada como material
elastoplástico. O principal objetivo é mostrar que modelos constitutivos simples empregados na
microestrutura em conjunto com uma formulação baseada numa homogeneização computacional são
uma alternativa aos modelos constitutivos macroscópicos complexos para o comportamento mecânico de
materiais heterogêneos usando um procedimento baseado no Método dos Elementos Finitos no âmbito de
uma teoria Multiescala. Uma série de exemplos envolvendo processos de microfissuração e plasticidade
é apresentada de modo a ilustrar qualitativamente a performance da modelagem proposta.
|
124 |
Análise experimental de pilares de concreto armado, com carga excêntrica, reforçados com chumbadores e concreto autoadensável (CAA) / Experimental analysis of reinforced concrete columns, under eccentric load, reinforced with wedge bolts and self compacting concrete (SCC)Virgens, Jeovan Pereira das 16 October 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-03-31T19:38:48Z
No. of bitstreams: 2
Dissertação - Jeovan Pereira das Virgens - 2015.pdf: 10009095 bytes, checksum: a8f3d2a6914adbb0c7cdcf49732ffc57 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-04-04T11:45:04Z (GMT) No. of bitstreams: 2
Dissertação - Jeovan Pereira das Virgens - 2015.pdf: 10009095 bytes, checksum: a8f3d2a6914adbb0c7cdcf49732ffc57 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-04-04T11:45:04Z (GMT). No. of bitstreams: 2
Dissertação - Jeovan Pereira das Virgens - 2015.pdf: 10009095 bytes, checksum: a8f3d2a6914adbb0c7cdcf49732ffc57 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-10-16 / This paper presents the experimental study of reinforcement concrete columns reinforced with wedge bolts and a 35 mm self compacting concrete jacket at the most compressed face. Nine columns with a 2000 mm height subjected to flexure and bending with initial eccentricity of 60 mm, named as: original column (Po) with a cross section of 120 mm x 250 mm; reference column (Pref) with a cross section of 155 mm x 250 mm and seven columns with a initial cross section of 120 mm x 250 mm, and later reinforced by the addition of 35 mm reinforcing layer, and various configurations of wedge bolts at its most compressed face. Except for the original column (Po), the columns were submitted to a 42.5 mm load eccentricity due to the attached concrete layer at the compressed face. Although failure of the wedge bolts did not accour, it was not possible to prevent detachment of the reinforcing layer. The results indicate that it is possible to structural rehabilitate reinforce concrete columns with the use of the strengthening methodology used in this research, resulting in average load capacity gains of 3,71 times compared to original column load (Po). / O presente trabalho apresenta o estudo experimental de pilares de concreto armado reforçados com parafusos chumbadores e acréscimo de camada com 35 mm de concreto autoadensável na face comprimida. Nove pilares, com alturas de 2000 mm, foram submetidos à flexão composta reta com excentricidade inicial de 60 mm, assim discriminados: um pilar original (Po) com seção transversal de 120 mm x 250 mm; um pilar de referência (Pref) com seção transversal de 155 mm x 250 mm e sete pilares, inicialmente moldados com seção transversal de 120 mm x 250 mm, e após, reforçados através da adição de camada de reforço de 35 mm e diversas configurações de posições de parafusos chumbadores na face comprimida. Exceto o pilar original (Po), os pilares foram submetidos à excentricidade inicial de carga de 42,5 mm, devido ao acréscimo da camada de reforço na face comprimida. Apesar de não ocorrer ruptura dos parafusos chumbadores, não foi possível evitar o desplacamento da camada de reforço. Os resultados obtidos indicam que é possível a reabilitação estrutural de pilares de concreto armado com o uso da metodologia de reforço empregada, obtendo ganho de capacidade de carga média de 3,71 vezes em relação ao pilar original (Po).
|
125 |
Análise do comportamento de pilares de concreto armado reforçados com chumbadores e concreto auto adensável / Analysis of the behavior of reinforced concrete columns strengthened with sleeve wedge bolts and a self-compacting concrete layerMarques, Marília Gonçalves 11 April 2014 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-03-05T20:16:17Z
No. of bitstreams: 2
Dissertação - Marília Gonçalves Marques - 2014.pdf: 6536401 bytes, checksum: 080ea60c6004cee2f33a28aab0065b39 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-03-05T20:16:35Z (GMT) No. of bitstreams: 2
Dissertação - Marília Gonçalves Marques - 2014.pdf: 6536401 bytes, checksum: 080ea60c6004cee2f33a28aab0065b39 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-05T20:16:35Z (GMT). No. of bitstreams: 2
Dissertação - Marília Gonçalves Marques - 2014.pdf: 6536401 bytes, checksum: 080ea60c6004cee2f33a28aab0065b39 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2014-04-11 / Strengthening of reinforced concrete columns by jacketing is one of the most common structural rehabilitation techniques in Brazil. For adequate performance, it is necessary, among others, to avoid detachment of the new concrete layer (strengthening material) from the old concrete substrate when the strengthened member is again in service conditions. This paper describes the test results of eight reinforced concrete rectangular columns subjected to combined compression and one-axis bending to evaluate the efficiency of using sleeve wedge bolts across the new concrete/old concrete interface to avoid detachment. The strengthening technique, in this case, consisted of adding a layer of self-compacting concrete to one column face. Two columns tested were monolithic and named PO (original column) e PR (reference column). The other six columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and its results gave information about column behavior without the use of strengthening. Column PR had a 155mm by 250 mm rectangular cross section and its cross section dimensions matched the strengthened columns but it was cast monolithically. To improve bond conditions between the existing concrete and the new concrete, the concrete surface was roughened and the outermost aggregate was exposed using hydro jetting. Holes along the concrete surface were made to insert the wedge bolts responsible for increasing the bond between the two concrete surfaces. The difference among the six strengthened columns consisted in the position and amount of bolts used. Results indicate the position and amount of the bolts significantly alters the strength capacity of the strengthened columns since premature rupture by concrete detachment was delayed. The reinforcement used was increased approximately three times the ultimate load of the original column, indicating the good performance of reinforcement. / ANÁLISE DO COMPORTAMENTO DE PILARES DE CONCRETO ARMADO REFORÇADOS COM CHUMBADORES E CONCRETO AUTO ADENSÁVEL
O reforço de pilares de concreto armado por encamisamento é uma das técnicas de reabilitação estrutural mais utilizada no Brasil. Para que este tipo de intervenção funcione, é preciso entre outras coisas evitar o desplacamento entre o concreto adicionado (material do reforço) e o concreto antigo (substrato) quando a peça reabilitada é colocada novamente em serviço. Neste trabalho são descritos os resultados dos ensaios de oito pilares de concreto armado, submetidos à flexo-compressão reta, com o intuito de avaliar a eficiência do uso de chumbadores metálicos cruzando a interface de ligação entre os concretos moldados em idades distintas, para evitar o desplacamento entre estes materiais. Dos oito pilares ensaiados, dois eram referências e foram denominados de PO (pilar original) e PR. (pilar referência). Os outros seis foram reforçados acrescentando-se uma camada de concreto auto-adensável de 35 mm à face comprimida. O pilar PO, tinha seção transversal de 120 x 250 mm, e forneceu informações sobre o comportamento da peça antes da execução do reforço. O pilar PR tinha seção transversal de 155 x 250 mm, e forneceu informações sobre o comportamento de uma peça monolitica de seção idêntica a dos pilares após o reforço. Para executar a intervenção, inicialmente escarificou-se, por hidrojateamento, a zona de interface a ser formada pelo contato entre o concreto do reforço e do substrato. Posteriormente, fizeram-se furos ao longo desta superfície, onde foram inseridos os chumbadores mecânicos responsáveis por aumentar a aderência entre os concretos. A diferença entre os seis pilares reforçados consistia justamente na variação da posição e da quantidade dos chumbadores usados em cada peça. Os resultados obtidos indicaram que a quantidade e a posição destes chumbadores interferiram significativamente na capacidade portante dos pilares reforçados, pois retardavam a ocorrência de uma ruptura prematura por desplacamento entre os concretos do reforço e do substrato. O reforço utilizado aumentou aproximadamente três vezes a carga de ruptura do pilar original, indicando o bom desempenho do reforço.
|
126 |
Análise numérica de estruturas de concreto com fibras utilizando mecânico do dano / Numerical analysis of concret reinforced with stelle fibers structures using damage mechanicsPereira Júnior, Wanderlei Malaquias 21 August 2014 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2015-03-27T13:42:08Z
No. of bitstreams: 2
Dissertação - Wanderlei Malaquias Pereira Júnior - 2014.pdf: 7970008 bytes, checksum: f601259b1df84616f459fd009136794b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-03-27T15:44:42Z (GMT) No. of bitstreams: 2
Dissertação - Wanderlei Malaquias Pereira Júnior - 2014.pdf: 7970008 bytes, checksum: f601259b1df84616f459fd009136794b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-27T15:44:42Z (GMT). No. of bitstreams: 2
Dissertação - Wanderlei Malaquias Pereira Júnior - 2014.pdf: 7970008 bytes, checksum: f601259b1df84616f459fd009136794b (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2014-08-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The work is a contribution to the mechanical numerical modeling of concrete structures with
steel fibers using constitutive models based on Damage Mechanics behavior. The same,
presents the formulation of a model proposed Damage admits that the concrete as initially
isotropic elastic material, but with the evolution of the damage process, the material exhibits
plastic deformations, anisotropy and bimodularidad induced damage. The incorporation of
fibers in the modeling is performed through a homogenization procedure. The constitutive
model for the concrete as well as the homogenization technique for dealing with the case of
fiber concrete are implemented on a structural analysis program bar finite element laminated
in layers. The parametric identification of the constitutive model together with the proposed
homogenization is carried out using experimental results from the literature. Finally,
numerical analysis of reinforced concrete beams reinforced with steel fibers and subjected to
bending are conducted to assess the applicability of the constitutive model considered in this
work. An attempt is thus contribute to the study of the deformation of fibrous concrete beams
in service, in order to aggregate results and discussions in a future proposal of Brazilian
technical standard for this type of structure. / O trabalho trata de uma contribuição à modelagem numérica do comportamento mecânico de
estruturas de concreto com fibras de aço utilizando modelos constitutivos baseados na Mecânica do
Dano. O mesmo, apresenta a formulação de um modelo de Dano proposto que admite o concreto como
material inicialmente isótropo e elástico, mas com a evolução do processo de danificação o material
exibe deformações plásticas, anisotropia e bimodularidade induzidas pelo dano. A incorporação das
fibras na modelagem é efetuada através de um procedimento de homogeneização. O modelo
constitutivo para o concreto, assim como a técnica de homogeneização para tratar do caso do concreto
com fibras são implementados em um programa para análise de estruturas de barras com elementos
finitos estratificados em camadas. A identificação paramétrica do modelo constitutivo, juntamente
com a proposta de homogeneização, é realizada utilizando resultados experimentais encontrados na
literatura. Por fim, análises numéricas de vigas de concreto armado reforçado com fibras de aço e
sujeitas à flexão são conduzidas no sentido de avaliar a aplicabilidade do modelo constitutivo tratado
neste trabalho. Procura-se, assim, contribuir para o estudo da deformabilidade de vigas de concreto
fibroso em serviço, com o intuito de agregar resultados e discussões numa futura proposta de norma
técnica brasileira para este tipo de estrutura.
|
127 |
Efeito da resist?ncia ao cisalhamento do concreto na flex?o de lajes de concreto armadoRocha, M?rcurie Janeai Mateus Araujo 04 September 2017 (has links)
Submitted by Luis Ricardo Andrade da Silva (lrasilva@uefs.br) on 2017-11-28T23:42:31Z
No. of bitstreams: 1
Dissertacao - Mercurie Janeai Mateus Araujo Rocha.pdf: 2758370 bytes, checksum: 944f4fc5f24c7c08b8ca7abcf999414a (MD5) / Made available in DSpace on 2017-11-28T23:42:31Z (GMT). No. of bitstreams: 1
Dissertacao - Mercurie Janeai Mateus Araujo Rocha.pdf: 2758370 bytes, checksum: 944f4fc5f24c7c08b8ca7abcf999414a (MD5)
Previous issue date: 2017-09-04 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / In this work the influence of the shear strength of the concrete in the bending of reinforced concrete slabs was studied through two models of analysis. The first model (proposed model 1) combines an isotropic damage model for concrete, proposed by Oliver et al., and the perfect elastoplastic model for steel reinforcement. The second model (proposed model 2), which is in fact a modification of the previous model, introduces a unique damaging to the concrete transverse modulus of elasticity, based on a proposal by Matzenbacher. The behavior of slabs was simulated through the Classical Theory of Laminates and the variational formulation of the problem was developed through the Principle of Virtual Works. The numerical treatment of the problem was based on the Finite Element Method, using a finite rectangular element with 24 degrees of freedom, incorporating Newton-Raphson's incremental-iterative process with load control and displacement control. The validation of the two models was based on the simulation of four rectangular slabs under bending, whose analysis revealed that it is essential to damage the concrete modulus of elasticity when using the damage mechanics. / Neste trabalho foi estudada a influ?ncia da resist?ncia ao cisalhamento do concreto na flex?o de lajes de concreto armado, atrav?s de dois modelos de an?lise. O primeiro modelo (modelo proposto 1) combina um modelo de dano isotr?pico para o concreto, proposto por Oliver e colaboradores, e o modelo elastopl?stico perfeito para o a?o das armaduras. O segundo modelo (modelo proposto 2), que na verdade ? uma modifica??o do modelo anterior, introduz uma danifica??o exclusiva para o m?dulo de elasticidade transversal do concreto, baseado em uma proposta de Matzenbacher. O comportamento das lajes foi simulado atrav?s da Teoria Cl?ssica de Laminados sendo desenvolvida a formula??o variacional do problema por meio do Princ?pio dos Trabalhos Virtuais. O tratamento num?rico do problema foi baseado no M?todo dos Elementos Finitos, utilizando um elemento finito retangular com 24 graus de liberdade, incorporando o processo incremental-iterativo de Newton-Raphson com controle de carga e controle de deslocamento. A valida??o dos dois modelos se deu a partir da simula??o de quatro lajes retangulares sob flex?o, cujas an?lises revelaram ser imprescind?vel a danifica??o do m?dulo de elasticidade transversal do concreto ao se usar a mec?nica do dano.
|
128 |
Estudo da viabilidade econômica da implantação de coberturas termoacústicas com painéis fotovoltáicos em edificações: estudo de caso em uma instituição de ensino superior / Study of the economic viability of the implantation of thermoacoustic roofing with photovoltaic panels in buildings: case study in a higher education institutionBRAZ, Sérgio Cabeça 20 March 2018 (has links)
Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-05-28T19:40:11Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoViabilidadeEconomica.pdf: 4279683 bytes, checksum: f72753ee2e8408cc56a75522a4acc27b (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-05-28T19:41:22Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoViabilidadeEconomica.pdf: 4279683 bytes, checksum: f72753ee2e8408cc56a75522a4acc27b (MD5) / Made available in DSpace on 2018-05-28T19:41:22Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_EstudoViabilidadeEconomica.pdf: 4279683 bytes, checksum: f72753ee2e8408cc56a75522a4acc27b (MD5)
Previous issue date: 2018-03-20 / Com a evolução da humanidade e o aparecimento de novas tecnologias na construção civil aliado a necessidade de conforto ambiental, redução dos impactos ambientais e do consumo de energia elétrica, torna-se indispensável o uso de novos materiais e fontes de energias renováveis nas edificações para redução dos custos. Neste cenário foram estudadas as coberturas das edificações de uma instituição de ensino superior no estado do Pará, visando o conforto ambiental e redução de custos no consumo de energia elétrica. Assim realizou-se pesquisa exploratória, onde foram consideradas a área da edificação, tipo de cobertura, o consumo de energia elétrica e cálculos através do fluxo de caixa projetado com horizonte temporal de 25 anos, compatível com a vida útil do sistema. Obteve-se assim fluxo de caixa descontado, o payback e o valor presente líquido. Os resultados revelaram que o uso da telha termoacústica nas coberturas com a implantação do sistema de energia solar fotovoltaica, como alternativa para redução de custos, é viável para as edificações estudadas com economicidade em torno de 13%, tempo de retorno 12/13 anos (50% da vida útil do sistema) e VPL de, em média, 44% do investimento inicial. Para as passarelas cobertas da Instituição que em sua totalidade têm aproximadamente 5 km, não se mostrou viável a implantação do sistema fotovoltaico. / With the evolution of humanity and the appearance of new technologies in civil construction combined with the need for environmental comfort, reduction of environmental impacts and consumption of electricity, it becomes indispensable to use new materials and sources of renewable energy in buildings for reduction costs and environmental impacts. In this scenario, the coverage of the buildings of a higher education institution in the state of Pará was studied aiming at the environmental comfort and reduction of costs in the consumption of electric energy. Exploratory research was carried out, considering the area of the building, type of coverage, the consumption of electric energy and calculations through the projected cash flow with a time horizon of 25 years compatible with the useful life of the system. We thus obtained discounted cash flow, payback and net present value. The results showed that the use of the thermoacoustic tile in the roofs with the implantation of the photovoltaic solar energy system as an alternative for cost reduction is feasible for the studied buildings with a saving of around 13%, time of return 12/13 years (50% of the system's useful life) and NPV of, on average, 44% of the initial investment. For the covered walkways of the Institution that in its totality is approximately 5km, the implantation of the photovoltaic system was not viable.
|
129 |
Análise quantitativa da degradação de fachadas em revestimento cerâmico: estudo de caso em edifícios de Belém– PA / Quantitative analysis of façade degradation in ceramic tiling: case study in buildings in Belém– PASANTOS NETTO, Clementino José dos 15 June 2018 (has links)
Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-08-31T20:13:35Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-08-31T20:14:11Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) / Made available in DSpace on 2018-08-31T20:14:12Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5)
Previous issue date: 2018-06-15 / Este estudo aborda o levantamento e a identificação de manifestações patológicas nas fachadas
de cinco edifícios, com sistema de revestimento cerâmico (SRC), da Região Metropolitana de Belém/ PA, por meio do modelo de quantificação de danos adaptado de Silva (2014). A metodologia proposta consiste em uma sistematização do processo de inspeção, com identificação, mapeamento e quantificação das manifestações patológicas nas fachadas dos edifícios, aplicando o Fator de Danos (FD) como forma de avaliar o comportamento da degradação em função de fatores de influência como o tipo de manifestação, idade e orientação solar das fachadas, analisando também agentes de degradação como a chuva dirigida, radiação solar e umidade. Posteriormente, foi aplicado o Fator de Danos Combinado (FDC) que atribui índices de ponderação ao FD, relativos ao custo de reparação de cada anomalia observada. Analisando os resultados, verificou-se que a manifestação patológica manchas (MA) no revestimento cerâmico foi a que apresentou maior percentual de ocorrência, ou seja, maior área degradada, entre os tipos de anomalias observadas. Além disso, essa manifestação apresentou valores elevados de FDMédio em todas as orientações cardeais e valores expressivos desse índice de degradação, tanto nas fachadas com menos de 20 anos, quanto nas com mais de 20 anos. Esses resultados são diretamente influenciados pelo clima extremamente agressivo da região, que apresenta constantes chuvas e elevada umidade relativa do ar (atingindo até 95%), favorecendo a propagação dessa anomalia (manchamento) já nas primeiras idades da edificação, visto que, as fachadas mais jovens analisadas (10 e 16 anos) já possuíam índices de degradação consideráveis essa manifestação patológica. A orientação que apresentou maior fator de degradação foi a direção Sul (FDTotal=9,42%), influenciado diretamente pelo fenômeno da chuva dirigida, que apresenta seu maior Índice de Chuva Dirigida (ICD) na direção Norte, afetando as fachadas orientadas na direção Sul. Após a aplicação do FDC, a manifestação patológica descolamento/ desplacamento (DC) cerâmico passou a apresentar o maior índice de degradação (FDCMédio=39,22%), devido ao seu alto custo de restauração, quando comparado ao valor de reparo das outras anomalias avaliadas. Por meio
dos histogramas de FDTotal e FDCTotal, observou-se uma curva exponencial característica que apresenta uma diminuição na frequência de ocorrência à medida que aumenta o valor do índice de degradação. Tal curva característica também foi observada em Silva (2014) e Souza (2016). / This study approaches the collect and identification of pathological manifestations in the façades of five buildings, with ceramic coating system (SRC), in the Metropolitan Region of Belém / PA, using Silva 's adapted damage quantification model (2014). The proposed methodology consists of a systematization of the inspection process, with identification, mapping and quantification of the pathological manifestations in the façades of the buildings, applying the Damage Factor (FD) as a way to evaluate the degradation behavior as a function of influence factors such as type of manifestation, age and solar orientation of the facades, also analyzing agents of degradation such as directed rain, solar radiation and humidity. Subsequently, the Combined Damage Factor (FDC) was applied, which assigns weighting
indices to the FD, related to the repair cost of each observed anomaly. Analyzing the results, it was verified that the pathological manifestation stain (MA) on the ceramic coating was the one that presented the highest percentage of occurrence, that is, greater degraded area, among the types of anomalies observed. In addition, this manifestation presented high values of FDC in all cardinal orientations and expressive values of this index of degradation, both in façades under 20 years and in those with more than 20 years. These results are directly influenced by the extremely aggressive climate of the region, which presents constant rains and high humidity (up to 95%), favoring the propagation of this anomaly (staining) already in the first ages of the building, since the façades (10 and 16 years old) already had considerable degradation rates of this pathological manifestation. The orientation that presented the highest degradation factor was the South direction (FDTotal=9.42%), influenced directly by the phenomenon of directed rainfall, which presents its highest Directed Rain Index (ICD) in the North direction, affecting the facades oriented in the South direction. After the application of FDC, the pathological manifestation of ceramic detachment / displacement (DC) presented the highest degradation index (FDCMédio=39.22%), due to its high restoration cost, when compared to the repair value of the other anomalies evaluated. By means of the histograms of FDTotal and FDCTotal, a characteristic exponential curve was observed that shows a decrease in the frequency of occurrence as the value of the degradation index increases. This characteristic curve was also
observed in Silva (2014) and Souza (2016).
|
130 |
Segurança estrutural de uma ponte ferroviária em concreto armado sobre o rio Mãe Maria / Structural safety of a reinforced concrete bridge over the river Mãe MariaSANTOS, Régis Rivo Ferreira dos 21 December 2010 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-03-12T13:36:54Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_SegurancaEstruturalPonte.pdf: 2733492 bytes, checksum: c9ff2b4470605b876872e4a86e326c33 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-13T13:37:15Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_SegurancaEstruturalPonte.pdf: 2733492 bytes, checksum: c9ff2b4470605b876872e4a86e326c33 (MD5) / Made available in DSpace on 2013-03-13T13:37:15Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_SegurancaEstruturalPonte.pdf: 2733492 bytes, checksum: c9ff2b4470605b876872e4a86e326c33 (MD5)
Previous issue date: 2010 / FAPESPA - Fundação Amazônia de Amparo a Estudos e Pesquisas / O estudo do comportamento de pontes ferroviárias vem tomando grande destaque na área experimental,
devido muitas das vezes haver a necessidade de um aumento dessas cargas móveis. A companhia
VALE a partir de um convênio estabelecido com a UFPA (Universidade Federal do Pará), buscou
realizar estudos das capacidades resistentes das pontes ferroviárias, que compõem a Estrada de Ferro
Carajás (EFC), para futuros casos de carregamentos que passarão de 32 tf para 40 tf, o que provoca
mudanças consideráveis no comportamento da estrutura. A falta de manutenção ou uma manutenção
irregular das pontes de concreto armado podem resultar em manifestações patológicas que podem
comprometer a segurança e ao risco de intervenção do escoamento. Dentre as OAE’s (Obras de Arte
Especial) já analisadas, encontra-se a ponte sobre o Rio Mãe Maria localizada no município de Marabá,
estado do Pará, transpondo o rio Mãe Maria, identificada como OAE 50A, apresenta um traçado
retilíneo executada em concreto armado moldada “in loco”, é constituída por dois vãos hiperestáticos,
totalizando 64,20 m, transpondo o leito do rio em dois vãos de 20 m e com seção transversal
oferecendo a largura de 5,85 m. Com isso tornou-se indispensável para avaliação de sua integridade
física a monitoração com extensômetros elétricos de resistência (EER) dos elementos (laje, longarina,
blocos, encontros e tubulões) que compões a estrutura durante a passagem dos trens carregados de
minério. Além da monitoração, foram realizados ensaios não-destrutivos como: dureza superficial
através da esclerometria e a estimativa do cobrimento da armadura e localização da mesma por meio da
pacometria, ensaios destrutivos como: extração de corpos-de-prova para determinar a compressão
diametral e o módulo de elasticidade do concreto e a resistência a penetração através do teste de
carbonatação inerentes a questão de durabilidade do mesmo, que serão comparados com a memória de
cálculo e com os modelos computacionais tridimensionais desenvolvidos via “software”
comercialSAP2000® (COMPUTERS AND STRUCTURES), que utiliza o método dos elementos
finitos (MEF). O MEF foi utilizado para obtenção dos esforços permitindo as verificações de segurança
de acordo com as recomendações normativas, tais análises comparativas são apresentadas e discutidas
para a conclusão do comportamento das longarinas. Conhecendo com precisão a capacidade estrutural da ponte e a sua vida útil, pode-se assegurar o tráfego de composições com maior segurança. / The study of the behavior of highway bridges has been, taking great prominence in the experimental area, because often there is a need for an increase of these mobile charges. The Company Vale, is worth form an agreement mad with the UFPA, sought to conduct studies of the resistant capacity of
railway bridges that make up the Carajás raiboad, which passed to future shipments wich passed from
32 tf to 40 tf, causing considerable changes in the behavior of the structure a lack of maintenance or a
maintenance of irregular reinforced concrete bridges can result pathological manifestations that can
compromise safety and the risk of intervention by runoff. About the abeady discussed is the bridge over
the river boiler located in the city of Marabá in the state of Pará, bridging the river identified as Mãe
Maria 50A OAE, has a rectilinear path bacuted reinforced concrete cast in place consists of two spans
hyperstatic totaling 64,20 m transposing the riverbeat in two spans of 20 m and cross section width of
5,85 m offering. It has become essential to assess their physical an monitoring with resistance electric
gauges (slab, longitudinal beam, foundation blocks and piles, and encounters) that make up structure
during the passage of trains carrying in addition to monitoring were performed as surface hardness by
esclerometry and the estimation of the armature coating and the same location through pacometry,
destructive tests such as extraction of test specimens to determine the tensile resistance and modulus of
elasticity of concrete and the resistance to penetration testing through the carbonation of the inherent
question of durability of the same to be compared with memory and calculation with three dimensional
computer models developed via commercial software SAP2000® (Computers and Structures) the uses
finite element method (MEF). The MEF was used to obtain the efforts enabling security checks
according to standard recommendations, these comparisons are presented and discussed for the
completion of the behavior of the stringers, knowing the precise structural capacity of the bridge and
it’s useful life, you can ensure traffic compositions with greater safety.
|
Page generated in 0.1114 seconds