• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 469
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 482
  • 269
  • 154
  • 146
  • 84
  • 64
  • 63
  • 58
  • 52
  • 50
  • 46
  • 44
  • 44
  • 44
  • 44
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Teste do degrau de seis minutos na avaliação da capacidade submáxima de exercício em pacientes com doença pulmonar obstrutiva crônica

Hübner, Alexandra de Albuquerque January 2009 (has links)
INTRODUÇÃO: A maior repercussão funcional da doença pulmonar obstrutiva crônica é a redução da tolerância ao esforço físico. Testes de campo, caracterizados por alcançar esforço submáximo, são mais adequados a pacientes, pois são capazes de representar semelhante nível de atividades quotidianas do indivíduo. Recentemente tem sido utilizado o teste do degrau de seis minutos (TD6) nas avaliações físicas de pacientes com doença intersticial pulmonar, mas este ainda não foi estudado em pacientes com doença pulmonar obstrutiva crônica (DPOC). OBJETIVO: Avaliar o desempenho dos pacientes com DPOC em diferentes graus da doença por meio do TD6 e comparar as variáveis relacionadas ao esforço físico com o teste da caminhada de seis minutos (TC6). MATERIAL E MÉTODOS: Estudo transversal, prospectivo em pacientes estáveis com diagnóstico clínico e espirométrico de DPOC, estratificados pelo critério GOLD. Todos realizaram espirometria, preencheram questionário de atividade física e realizaram o TD6 e o TC6, com intervalo máximo de uma semana entre os dois testes. Cada teste foi realizado duas vezes no mesmo dia e foi escolhido aquele com maior desempenho. RESULTADOS: 97 pacientes avaliados (GOLD II: 28, III: 38, IV: 31). Pacientes dos grupos II e IV apresentaram diferença estatística significante (p<0,001) no desempenho do TD6 (21,93±6,36 m x 16,2±5,83 m, respectivamente) bem como no TC6 (463,89±67,26 m x 350,55±97,35 m, respectivamente). Pacientes do grupo IV dessaturaram e interromperam mais os testes, associaram-se com inatividade e tiveram menor desempenho nos dois testes que os outros grupos. A freqüência cardíaca máxima (FC máx) atingida (%previsto) no TD6 foi maior que no TC6, independente do grupo. Os escores de dispnéia e de fadiga de membros inferiores foram maiores no TD6. Pacientes que mostraram queda SpO2>4 pontos no TD6 também dessaturaram no TC6. A distância vertical percorrida (DVP) no TD6 correlacionou-se significativamente com a distância no TC6 (p<0,001; r>0,65 em todos os grupos), com a FC max no TD6 (p<0,001; r=0,367) e com a SpO2 mínima atingida no TD6 (p=0,017;r=0,243). Não houve correlação da DVP com os escores de dispnéia e de fadiga de membros inferiores. CONCLUSÃO: Assim como observado no TC6, o desempenho no TD6 foi menor em estágios mais graves da DPOC, associou-se à distância percorrida no TC6 e desencadeou maior intensidade de esforço físico. Por induzir similar dessaturação, o TD6 pode ser uma ferramenta alternativa na avaliação da hipoxemia induzida pelo exercício de pacientes com DPOC, com a vantagem de necessitar menor espaço físico para sua realização.
42

Sistematização de uma abordagem da medição de uma produção diversificada e seus desempenhos num ambiente industrial pelo método das Unidades de Esforço de Produção-UEPs

Fernandes, Joaquim de Sousa January 2003 (has links)
As atividades ligadas à medição da produção em uma organização industrial monoprodutora são facilmente feitas em função de uma única unidade de medida: a quantidade total produzida (controle físico), com seus custos totais de fabricação associados (controle monetário). A fabricação simultânea de vários produtos diversificados aumenta a complexidade dessas atividades, principalmente pela inexistência de uma unidade de medida comum a toda a produção. Este trabalho desenvolveu-se tendo em mente procurar uma solução alternativa aos métodos usuais utilizados para medir uma produção, quais sejam: número de horas, faturamento, quantidade física, entre outras, buscando racionalizar o processo de gestão Industrial, pela definição de uma unidade de medida comum a toda a produção o qual transforma uma fábrica multiprodutora real numa fábrica de um único produto representativo e equivalente a toda a produção. A Unidade de Esforço de Produção, UEPs, responde satisfatoriamente a essa necessidade, unificando e homogeneizando as atividades desenvolvidas por uma fábrica multiprodutora. Sua definição materializa sob uma mesma base de esforços (despesas) alocados aos vários postos operativos (máquinas e equipamentos) na fabricação dos diversos produtos. A organização escolhida para que fosse desenvolvido o presente trabalho, Estudo de Caso, serve como modelo para pesquisas futuras em outros tipos de organização que produzem produtos diversificados. O objetivo principal deste estudo é a Medição de uma Produção Diversificada e de seus Desempenhos, a saber: Custos, Rendimento, Eficiência, Produtividade tanto horária quanto econômica, num ambiente industrial pelo Método das UEPs. É uma contribuição para o controle das atividades no âmbito da gestão Industrial. Os resultados apresentados no presente trabalho indicam que as organizações industriais multiprodutoras tem neste Método (UEPs) uma ferramenta gerencial para poder Medir e Controlar os seus Desempenhos fazendo comparações entre os Desempenhos Planejados (Metas) e os Desempenhos verdadeiramente ocorridos.
43

Esforço fiscal dos municípios pernambucanos: uma análise de fronteira estocástica

Siqueira, Kleyton José da Silva Pereira de 31 May 2014 (has links)
Submitted by Suethene Souza (suethene.souza@ufpe.br) on 2015-03-13T17:02:03Z No. of bitstreams: 2 DISSERTAÇÃO Kleyton José de Siqueira.pdf: 1102784 bytes, checksum: 24a4c5f416d3d1a4e28840f597cf9855 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-13T17:02:03Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Kleyton José de Siqueira.pdf: 1102784 bytes, checksum: 24a4c5f416d3d1a4e28840f597cf9855 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014-05-31 / FACEPE / Este trabalho teve como objetivo estudar a eficiência tributária dos municípios pernambucanos e construir o índice de esforço fiscal para estes entes federados. Neste sentido, buscou-se verificar que características socioeconômicas tinham influência na arrecadação municipal própria, ou seja, a arrecadação advinda da tributação de competência exclusiva dos municípios. Dessa forma, foram levantados dados sobre a arrecadação com Imposto Sobre Serviços de qualquer Natureza – ISSQN, Imposto Predial e Territorial Urbano – IPTU e Imposto sobre Transmissão de Bens Imóveis – ITBI, além das informações socioeconômicas dos municípios, como: População, Produto Interno Bruto, Receitas, Despesas, Cota recebida do Fundo de Participação dos Municípios – FPM etc. Para a estimação do esforço fiscal dos municípios pernambucanos e avaliação da eficiência na arrecadação de impostos por estas unidades federativas foi utilizada a metodologia de fronteira estocástica de produção de impostos, conforme Coelli (1992), com dados em painel para os anos de 2000 a 2009 de 140 municípios do Estado de Pernambuco. Os resultados apontaram para uma grande concentração da arrecadação na região metropolitana, bem como para uma concentração da arrecadação em poucos municípios (Recife, Caruaru e etc.), quando analisadas as regiões de desenvolvimento. Os resultados ainda mostraram que a renda municipal é preponderante para elevação da eficiência na arrecadação de impostos e que existe um indício de “preguiça fiscal”, uma vez que quando os municípios recebem transferências de recursos da União através do FPM tendem a diminuir o esforço em arrecadar impostos. E por fim, foi constatado que os municípios pernambucanos tendem a estar distribuídos espacialmente em clubes de eficiência, com evidências de municípios vizinhos apresentarem correlação espacial positiva em relação à arrecadação tributária.
44

Função cardíaca: predição da carga de treinamento muscular inspiratório e correlação com dados pneumofuncionais de indivíduos com insuficiência cardíaca

LIMA, Peterson Filipe Pinheiro de 29 September 2016 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-09-25T22:13:36Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTACÃO Peterson Filipe Pinheiro de Lima.pdf: 1572424 bytes, checksum: ef7d7b0cb76e3f54de0974294ce77289 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-27T22:44:37Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTACÃO Peterson Filipe Pinheiro de Lima.pdf: 1572424 bytes, checksum: ef7d7b0cb76e3f54de0974294ce77289 (MD5) / Made available in DSpace on 2018-09-27T22:44:37Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTACÃO Peterson Filipe Pinheiro de Lima.pdf: 1572424 bytes, checksum: ef7d7b0cb76e3f54de0974294ce77289 (MD5) Previous issue date: 2016-09-29 / FACEPE / Existe uma associação entre fração de ejeção do ventrículo esquerdo (FEVE), strain longitudinal global (SLG) e o consumo máximo de oxigênio (VO2max) com o declínio da função respiratória, sobretudo no desenvolvimento de disfunções musculares inspiratórias e no comprometimento da qualidade de vida de indivíduos com insuficiência cardíaca (IC). Estes marcadores cardíacos podem ser uma importante ferramenta para a determinação da carga de treinamento muscular inspiratório (TMI) nesta população. Esta dissertação é composta por dois artigos originais, cujos objetivos foram avaliar a reprodutibilidade do PowerBreathe® KH2 para a avaliação da pressão inspiratória máxima (PImax) em adultos saudáveis e comparar as cargas de TMI determinadas pela manovacuometria digital e eletrônica em adultos jovens saudáveis (Artigo 1); e avaliar a influência da FEVE, do SLG e do VO2max na determinação da PImax e prescrição da carga de TMI em indivíduos com IC (Artigo 2). Artigo 1: Realizou-se um estudo transversal que randomizou o uso de dois equipamentos para avaliação da PImax de adultos jovens saudáveis do ponto de vista pneumofuncional. Todos os voluntários realizaram, no mínimo, três manobras aceitáveis em cada teste, segundo os critérios de reprodutibilidade da American Thoracic Society/European Respiratory Society (ATS/ERS). Para a avaliação da reprodutibilidade intraobservador e da concordância, foram utilizados o coeficiente de correlação intraclasse (CCI) e o método Bland-Altman, respectivamente. Participaram 36 voluntários. O PowerBreathe® KH2 apresentou reprodutibilidade adequada. Encontrou-se viés entre o manovacuômetro GlobalMed MVD-300 e o PowerBreathe® KH2 (viés=5,83; IC95%= -8,82 a 20,49), e o manovacuômetro GlobalMed MVD-300 e o PowerBreathe® Breathe-Link (viés=5,14; IC95%= 13,37 a 23,65). Não houve concordância entre os métodos digital e eletrônico em adultos saudáveis (viés=5,32; IC95%= -10,10 a 20,74). Artigo 2: Realizou-se um estudo transversal com 37 indivíduos com IC avaliados pela FEV e pelo SLG fornecidos pela ecocardiografia, e pelo VO2max obtido pela ergoespirometria. O SLG apresentou correlação com a carga de TMI calculada pelos métodos convencional (r=0,367; p=0,030) e eletrônico (r=0,397; p=0,018) e, o VO2max, com a carga de TMI calculada pelo método convencional (r=0,395; p=0,015). Na análise de regressão, o SLG e o VO2max apresentaram influência estatisticamente significativa sobre a PImax e a carga de TMI. Conclui-se que o PowerBreathe® KH2 e o PowerBreathe® Breathe-Link são reprodutíveis e não apresentaram concordância com o manovacuômetro digital GlobalMed® MVD-300 para avaliação da PImax em adultos saudáveis. Logo, os métodos digital e eletrônico para a determinação da carga de TMI não apresentaram concordância em adultos saudáveis e pacientes com IC. Em pacientes cardiopatas, o SLG e o VO2max podem modificar a carga de TMI. Apesar do PowerBreathe® KH2 e do PowerBreathe® Breathe-Link não poderem substituir o manovacuômetro digital GlobalMed® MVD-300, sugere-se a introdução deste novo equipamento na prática clínica e na pesquisa científica como teste complementar da função respiratória em adultos saudáveis e indivíduos com IC. / There is an association between left ventricular ejection fraction (LVEF), global longitudinal strain (SLG) and maximal oxygen consumption (VO2max) with respiratory function decline, especially in the development of inspiratory muscle dysfunctions and impairment of quality of life of individuals with heart failure (HF). These cardiac markers can be an important tool for determining the inspiratory muscle training load (IMT) in this population. This dissertation is composed of two original articles, whose objectives were 1) to evaluate the reproducibility of PowerBreathe® KH2 for the assessment of maximal inspiratory pressure (MIP) in healthy adults and to compare the IMT loads determined by digital and electronic manovacuometry in healthy young adults (Article 1) and 2) to evaluate the influence of LVEF, SLG and VO2max on determination of MIP and prescription of IMT load in individuals with HF (Article 2). Article 1: A cross-sectional study was carried out that randomized the use of two devices to evaluate the MIP of healthy young adults from the pneumofunctional point of view. All volunteers performed at least three acceptable maneuvers in each test, according to the American Thoracic Society/European Respiratory Society (ATS/ERS) reproducibility criteria. For the intraobserver reproducibility and agreement, the intraclass correlation coefficient (ICC) and the Bland-Altman method, respectively, were used. Thirty-six volunteers participated. The PowerBreathe® KH2 showed adequate reproducibility. GlobalMed MVD-300 manometer and PowerBreathe® KH2 (bias = 5.83, IC95% = -8.82 to 20.49) were found, and the GlobalMed MVD-300 manometer and PowerBreathe® Breathe-Link (bias = 5.14, 95% CI = 13.37 to 23.65). There was no agreement between the digital and electronic methods in healthy adults (bias = 5.32, 95% CI = -10.10 to 20.74). Article 2: A cross-sectional study was performed with 37 individuals with HF evaluated by FEV and SLG provided by echocardiography, and by VO2max obtained by ergospirometry. The SLG presented a correlation with the IMT load calculated by conventional methods (r = 0.367, p = 0.030) and electronic (r = 0.377, p = 0.018) and VO2max with the IMT load calculated by the conventional method (r = 0.365, p = 0.015). In the regression analysis, SLG and VO2max had a statistically significant influence on MIP and TMI loading. We concluded that the PowerBreathe® KH2 and the PowerBreathe® Breathe-Link are reproducible and have not complied with the GlobalMed® MVD-300 digital manovacuometer for evaluation of PImax in healthy adults. Therefore, the digital and electronic methods for determining the IMT load did not agree with healthy adults and patients with HF. In cardiac patients, SLG and VO2max can modify the TMI load. Although the PowerBreathe® KH2 and PowerBreathe® Breathe-Link cannot replace the GlobalMed® MVD-300 digital manometer, we suggest to introduce this new equipment into clinical practice and scientific research as a complementary test of respiratory function in healthy adults and individuals with HF.
45

Histomorfometria e estereologia do gel do biopolímero do melaço da cana-de-açúcar implantado em bexiga de coelhos

RANGEL, Artur Eduardo de Oliveira 01 September 2011 (has links)
Submitted by Pedro Barros (pedro.silvabarros@ufpe.br) on 2018-09-03T22:12:47Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Artur Eduardo de Oliveira Rangel.pdf: 4239586 bytes, checksum: 52268fa84dd54fa644af5442a0959869 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-17T22:24:18Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Artur Eduardo de Oliveira Rangel.pdf: 4239586 bytes, checksum: 52268fa84dd54fa644af5442a0959869 (MD5) / Made available in DSpace on 2018-09-17T22:24:18Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) TESE Artur Eduardo de Oliveira Rangel.pdf: 4239586 bytes, checksum: 52268fa84dd54fa644af5442a0959869 (MD5) Previous issue date: 2011-09-01 / Introdução: Até o presente não existe um produto que seja biocompatível, inabsorvível, de fácil manipulação, com custo benefício satisfatório para o implante endoscópico para tratamento do refluxo vesicoureteral e da incontinência urinária por insuficiência esfincteriana uretral. Objetivos: Analisar a resposta inflamatória, a biocompatibilidade, a estabilidade, quantificar a fibrose tecidual e a neoformação vascular no hospedeiro, do gel de biopolímero da cana-de-açúcar produzido pela Zooglea sp (BCA) e do dextranômero e ácido hialurônico Deflux® implantados em bexigas de coelhos. Método: Vinte coelhos, divididos em dois grupos de dez animais, receberam implantes na bexiga e foram submetidos à eutanásia após três dias e três meses. Cada animal recebeu dois implantes do Deflux® na metade anterior direita da bexiga, e dois implantes do biopolímero BCA na metade anterior esquerda da bexiga. Após a eutanásia dos animais e remoção da bexiga, um retângulo de tecido, medindo 1 x 1 cm, foi recortado em cada um dos implantes. Foram utilizadas técnicas histoquímicas de coloração Hematoxilina e Eosina para evidenciar infiltrados celulares e vasos sanguíneos, Resorcina-fucsina de Weigert com prévia oxidação com oxona (fibras do sistema elástico) e Tricrômico de Masson e Picro Sirius (colágeno). Tecnicas imunohistoquímicas de Avidina Biotina e o anti-corpo monoclonal anti-alfa actina para caracterização das células de músculo liso. Para a realização de controles negativos, o anticorpo primário foi substituído por PBS. A revelação da imunomarcação foi feita com solução de 3,3-diaminobenzidina tetrahidrocloreto. Resultados: O implante do Deflux® foi envolvido por uma cápsula fibrosa. O gel do Deflux® encontrava-se fragmentado em pequenas áreas, as quais eram homogêneas em sua organização e livres de células e vasos sanguíneos em seu interior. A suposição é que o implante do gel do Deflux® é um material imunologicamente inerte. O implante do gel do biopolímero da cana-de-açúcar, observou-se que o gel foi bem colonizado por matriz celular e vasos sanguíneos, um infiltrado inflamatório é visível em algumas áreas. Ainda, o implante foi envolvido por uma cápsula de fibrose. Diferentes áreas do gel do BCA mostram uma matriz fibrosa extracelular, embora sessões coradas pelo método tricrômico de Masson e Picro-Sirius sob luz polarizada, tenha mostrado uma pequena quantidade de colágeno, ou ausência do mesmo no gel do BCA. O gel foi metabolizado ou estava em metabolização pelas células. Por outro lado, existiam poucas áreas no total do implante, com o gel homogeneamente distribuído, quase toda sua extensão foi invadida por células ou vasos sanguíneos. Conclusão: Os achados sugerem que o biopolímero da cana-de-açúcar é biocompatível, integra-se ao tecido hospedeiro, permanecendo no local implantado. Sugerem que o gel induz um processo de remodelação e será substituído por tecido conjuntivo. A análise do terceiro grupo de animais após 12 meses do implante poderá confirmar a remodelação do implante com aumento do tecido residual, permitindo confirmar a estabilidade do implante no longo prazo. Esta pesquisa translacional visa o desenvolvimento de um novo produto para implante endoscópico para o tratamento do refluxo vesicoureteral e da incontinência urinária com custo/benefício favorável, possibilitando acesso às novas técnicas, usuários da rede pública de saúde. / Introduction: To date, no single ideal agent fulfills the requisites of being biocompatible, non-absorbable and easy to handle at a satisfactory cost-to-benefit ratio to be employed as an endoscopically injectable implant agent in the treatment of vesicoureteral reflux and urinary incontinence secondary to urethral sphincter insufficiency. Objectives: To evaluate the inflammatory response, biocompatibility and stability and to quantify fibrosis and neovascularization in host tissue after treatment with the sugarcane derived biopolymer gel manufactured by Zooglea sp (BCA) in comparison to dextranomers plus hyaluronic acid (Deflux®) as injection agents in rabbit urinary bladder implants. Methods: Twenty rabbits, divided into two groups of ten animals each, underwent urinary bladder implant placement and were euthanized at 3 days and 3 months post-implant. Each animal received two Deflux® implants in the right anterior half, and two BCA biopolymer implants in the left anterior half of the bladder. Histochemical staining was performed with hematoxillin and eosin (H&E) to reveal cellular infiltrates and blood vessels, Weigert’s resorcin fuchsin with oxon (elastic fibers) and Masson’s trichrome and picrosirius (collagen). Avidin-biotin Immunohistochemistry was performed with an anti-alpha actin primary antibody to characterize smooth muscle cells. Negative controls were performed with PBS used in place of the primary antibody. The reaction signal was developed with a 3,3'-diaminobenzidine tetrahydrochloride (DAB) solution. Results: Deflux® implants were clearly involved by a fibrous capsule. The Deflux® gel was found to scatter into small homogeneously organized areas lacking cells and blood vessels. The assumption is that Deflux® gel is an immunologically inert material. BCA biopolymer implants were well colonized by cellular matrix and blood vessels and showed areas of clearly visible inflammatory infiltrates. Furthermore, the implants were completely involved by a fibrous capsule. The BCA gel itself presented two patterns of organization. Several areas showed a fibrous extracellular matrix on H&E stain. Examination of these areas with Masson’s trichrome and Picrosirius stain under polarized light revealed minimal to absent collagen within the BCA polymer. The gel had been or was in the process of being metabolized by the cells. On the other hand, a few areas within the implant showed homogeneous distribution of the gel which was almost entirely invaded by cells or blood vessels. Conclusion: These findings suggest that the BCA polymer has a favorable biocompatibility profile, it integrates into the host tissue and remains at the injection site. The histopathological data suggest that the BCA gel induces a remodeling process and is replaced by connective tissue. Analysis of a third animal group at 12 months post-implant could confirm remodeling with increase of residual tissue and would allow assessment of long term implant stability. This translational research effort aims at developing a novel material to be used in endoscopic implants with a more favorable biocompatibility profile and cost-benefit ratio. Ultimately, such agent would grant access to modern treatment modalities to low income patients and beneficiaries of the “Sistema Unico de Saude”.
46

COMPORTAMENTO DA PERCEPÇÃO SUBJETIVA DE ESFORÇO APÓS APLICAÇÃO DE DIFERENTES MÉTODOS DE PROGRESSÃO DE TREINAMENTO AERÓBICO EM HOMENS SAUDÁVEIS

LUZ, R. S. 26 April 2013 (has links)
Made available in DSpace on 2018-08-01T21:36:25Z (GMT). No. of bitstreams: 1 tese_6378_Dissertação Roque Luz 2013 (1).pdf: 622291 bytes, checksum: 092d430b71a23ee53076930335007ad5 (MD5) Previous issue date: 2013-04-26 / Entender os mecanismos da percepção subjetiva de esforço (PSE) sempre foi um desafio por se tratar de um objeto de estudo subjetivo. Desde a sua concepção até os dias atuais muitos estudos buscam entender as correlações da PSE com diversos mecanismos fisiológicos. Pouco se sabe sobre as possíveis alterações que a PSE possa ter após período de treinamento aeróbico. Essa carência de estudos sobre a correlação da PSE com a frequência cardíaca (FC) no que diz respeito ao comportamento após período de treinamento motivou a realização deste estudo. O objetivo principal foi comparar o comportamento da PSE e da FC antes e após o treinamento em cada grupo e entre os grupos, além da correlação entre a PSE e FC. O presente estudo analisou o comportamento da PSE e FC durante teste cardiopulmonar de exercício em indivíduos submetidos a três diferentes programas de treinamento aeróbico por um período de 13 semanas ininterruptas. Os grupos foram submetidos a uma periodização ondulatória, crescente ou escalonada. As diferenças nas distribuições de intensidade estavam relacionadas à presença ou não de período com intensidade reduzida e ao formato de incremento da intensidade dos estímulos. Na análise estatística foi empregado o teste de Wilcoxon para avaliar a PSE antes e depois dentro do grupo e o teste de Mann-Whitney para a comparação da PSE entre os grupos. Para a análise do comportamento da FC empregou-se o teste t de Student pareado para cada grupo e o teste t de Student para amostras independentes na comparação entre os grupos. A correlação entre a PSE e FC foi obtida através da correlação de Pearson. O nível de significância adotado foi o de p<0,05. Constatou-se que somente o grupo escalonado apresentou diferenças no comportamento da PSE quando comparamos os testes inicial e final. O comportamento da FC foi alterado em todos os grupos apresentando redução dos valores em todos os estágios, com exceção de um aumento de valores, somente no último estágio do grupo ondulatório. Quando comparados os valores de PSE e FC entre os grupos as diferenças ocorreram pontualmente em alguns estágios sem a possibilidade de afirmar que existe relação direta entre os tipos de periodização e as variáveis estudadas. A correlação entre a PSE e FC ocorreu de forma positiva com valores de correlação ~0,72. Os dados sugerem que o comportamento da PSE pode sofrer alguma alteração após período de treinamento aeróbico, especificamente quando utilizado o método escalonado para a progressão de intensidades.
47

Explorando a intensidade de esforço em atletas de basquetebol, segundo tipos de fundamentos e posições : estudo a partir de equipe infanto-juvenil do Campeonato Paulista de 1996

Borin, João Paulo 1966- 13 November 1997 (has links)
Orientador: Aguinaldo Gonçalves / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-07-23T17:27:19Z (GMT). No. of bitstreams: 1 Borin_JoaoPaulo1966-_M.pdf: 6770808 bytes, checksum: dc92e54d96e5b543928a1e3bf31291af (MD5) Previous issue date: 1997 / Resumo: Nos últimos anos, registra-se crescente participação de crianças e adolescentes que iniciam a prática desportiva: uma modalidade que vem se destacando é o basquetebol, com elevado número de atletas disputando em várias categorias. Neste contexto esportivo, ponto relevante volta-se à intensidade do esforço a que esses jogadores são submetidos durante as partidas, cujo conhecimento toma-se de importância fundamental a técnicos, preparadores físicos e professores de educação física na elaboração, controle e aperfeiçoamento de treinamentos. O presente trabalho teve como objetivo estudar o comportamento da freqüência cardíaca durante a realização dos tipos de fundamentos da modalidade ocorridos ao longo do turno da fase de classificação do campeonato paulista de basquetebol, categoria infanto-juvenil. A partir de perspectiva observacional descritiva, a coleta de dados foi realizada nos doze jogadores da equipe masculina do Clube 22 de Agosto/ Araraquara que ao final do Campeonato sagraram-se campeões. Utilizou-se de monitor de freqüência cardíaca (polar Sport Tester 'MARCA REGISTRADA¿) para registro dos batimentos cardíacos e, para análise dos movimentos, câmera filmadora. Os dados coletados foram armazenados em banco computacional, produzindo-se informações sob formas tabular e gráfica, de medidas de centralidade, dispersão e limites de confiança inferior e superior da média. Os resultados apresentam flutuações dos batimentos cardíacos segundo tipos de fundamentos e posições dos atletas, apontando como destaque para os alas pela maior ocorrência na execução dos diferentes gestos desportivos e respostas cardíacas máximas chegando a 219 bpm. Remete-se à discussão a variabilidade de intensidade de esforço encontrada, bem como a especificidade de cada posição e comportamento diferenciado dos batimentos cardíacos / Abstract: In the last few years it has been registered an increasing participation of children and teenagers taking up the pratice of sports, in which Basketball has had an important role, with a high number of athletes competing in different categories. In this sports context, there is a relevant point that leads to the intensity of the effort which these players are put through during the game: to have this knowledge is of great importance for coaches, physical trainers and physical education teachers in the process of elaboration, control and improvement of the classes. The aim of the present work was to study the behavior of the heart rate during the fulfiment of the types of fumdamentals of Basketball, which took place during the classification rOlmdsof the Basketball Toumament of São Paulo (15 year-old players). From an observacional - escriptive perspective, the gathering of the data was done with the twelve players of the male team of "22 de Agosto Club" (AraraquaralS.P., Brazil), which ended up as the winner of this toumament. It was used a heartbeat monitor (polar Sport Tester 'TRADEMARK¿) in order to regiter the heartbeats and also a video camera to analyse the moves. AlI the data were kept in a computer file in graphics and tables, producing information of the average of the measurements of centricity, dispersion and limits of the inferior and superior liability. The results show inconsistancy of the heartbeats according to the types of fumdamentals and positions of the athletes, pointing out to the center players for the highest occurrences in the execution of the different sports moves and maximum heart responses reaching 219 bpm. This work also mentions the discussion of the different intensity of the effort met, as well as the particularization of each position and the different behavior of heartbeats / Mestrado / Mestre em Educação Física
48

Percepção do esforço físico: comparação entre as escalas visual analógica e CR10 de Borg / Perception of physical exertion: a comparison between the visual analogue and Borg´s CR10 scales

Galante Junior, Waldemar 10 March 2006 (has links)
A proposta deste estudo foi determinar se as escalas visual analógica (VAS) e CR10 (Category-Ratio) de Borg são eficientes para avaliar o esforço geral percebido em um teste de exercício físico dinâmico contínuo. A amostra foi composta por 20 participantes do sexo masculino, com idade entre 18 e 29 anos, universitários, saudáveis, sedentários e que apresentavam valores ergoespirométricos compatíveis com a normalidade (Consenso Brasileiro de Ergometria). Os participantes realizaram o protocolo do teste de exercício físico dinâmico contínuo do tipo rampa (TEFDC-R) em um cicloergômetro eletromagnético à 60 rpm, juntamente com a aplicação das escalas psicofísicas escolhidas. A freqüência do esforço na presença do exercício foi induzida através do aumento da complexidade e da resistência, com a utilização do teste já mencionado. Para a análise dos dados foi utilizada análise psicofísica e estatística paramétrica por meio da correlação de Pearson, regressão linear e teste t de Student. Foram encontradas correlações estatisticamente significativas (p<0,05) entre as escalas (r=0,97), as escalas em função do consumo de oxigênio (CR10: r=0,90; VAS: r=0,90) e em função da freqüência cardíaca (CR10: r=0,89; VAS: r=0,91). Foram encontrados também julgamentos precisos independente da escala utilizada (n=0,99; r2=0,998). Estes resultados sugerem que as magnitudes físicas das escalas VAS e CR10 de Borg são altamente correlacionadas. Além disso, em ambas as escalas, o aumento da potência, da freqüência cardíaca e do consumo de oxigênio corresponderam ao aumento das estimativas subjetivas dos participantes em relação ao esforço físico. Isto pode indicar uma boa interação entre as diferentes variáveis atuantes durante o exercício físico dinâmico contínuo. / The purpose of this study was to determine if the visual analogue and Borg´s CR10 (Category-Ratio) scales are efficient for assessment of the perceived general exertion in a continuous dynamic physical exercise test. The sample was composed of 20 healthy male university students, with ages ranging from 18 to 29, sedentary and presenting compatible spirometric values with normality (Brazilian Consensus on Ergometry). The subjects filled out the protocol of the ramp continuous dynamic physical exercise test (RCDPET) using an electrically braked cycle ergometer at a pace of 60 rpm, with the application of the psychophysical scales. The frequency of the effort during the exercise was induced through the increase of the complexity and the resistance, using the test already mentioned. For the data analysis psychophysics analysis and parametric statistics were used, through the Pearson correlation, linear regression and Student-t test. A clear linear correlation was found between the scales (r=0,97, p<0,05), the scales and oxygen uptake (CR10: r=0,90; VAS: r=0,90) and heart rate values (CR10: r=0,89; VAS: r=0,91). Precise assessment were also found irrespective from the scale used (n=0,99; r2=0,99). These results suggest that the physical magnitudes of VAS and Borg´s CR10 scales are highly correlated. Moreover, in both scales, the increase of the power, the heart rate and the oxygen uptaken corresponds to the increase of the subjective estimations of the participants in relation to the physical effort. These may indicate a clear interaction between the different variable present during the continuous dynamic physical exercise test.
49

Percepção do esforço físico: comparação entre as escalas visual analógica e CR10 de Borg / Perception of physical exertion: a comparison between the visual analogue and Borg´s CR10 scales

Waldemar Galante Junior 10 March 2006 (has links)
A proposta deste estudo foi determinar se as escalas visual analógica (VAS) e CR10 (Category-Ratio) de Borg são eficientes para avaliar o esforço geral percebido em um teste de exercício físico dinâmico contínuo. A amostra foi composta por 20 participantes do sexo masculino, com idade entre 18 e 29 anos, universitários, saudáveis, sedentários e que apresentavam valores ergoespirométricos compatíveis com a normalidade (Consenso Brasileiro de Ergometria). Os participantes realizaram o protocolo do teste de exercício físico dinâmico contínuo do tipo rampa (TEFDC-R) em um cicloergômetro eletromagnético à 60 rpm, juntamente com a aplicação das escalas psicofísicas escolhidas. A freqüência do esforço na presença do exercício foi induzida através do aumento da complexidade e da resistência, com a utilização do teste já mencionado. Para a análise dos dados foi utilizada análise psicofísica e estatística paramétrica por meio da correlação de Pearson, regressão linear e teste t de Student. Foram encontradas correlações estatisticamente significativas (p<0,05) entre as escalas (r=0,97), as escalas em função do consumo de oxigênio (CR10: r=0,90; VAS: r=0,90) e em função da freqüência cardíaca (CR10: r=0,89; VAS: r=0,91). Foram encontrados também julgamentos precisos independente da escala utilizada (n=0,99; r2=0,998). Estes resultados sugerem que as magnitudes físicas das escalas VAS e CR10 de Borg são altamente correlacionadas. Além disso, em ambas as escalas, o aumento da potência, da freqüência cardíaca e do consumo de oxigênio corresponderam ao aumento das estimativas subjetivas dos participantes em relação ao esforço físico. Isto pode indicar uma boa interação entre as diferentes variáveis atuantes durante o exercício físico dinâmico contínuo. / The purpose of this study was to determine if the visual analogue and Borg´s CR10 (Category-Ratio) scales are efficient for assessment of the perceived general exertion in a continuous dynamic physical exercise test. The sample was composed of 20 healthy male university students, with ages ranging from 18 to 29, sedentary and presenting compatible spirometric values with normality (Brazilian Consensus on Ergometry). The subjects filled out the protocol of the ramp continuous dynamic physical exercise test (RCDPET) using an electrically braked cycle ergometer at a pace of 60 rpm, with the application of the psychophysical scales. The frequency of the effort during the exercise was induced through the increase of the complexity and the resistance, using the test already mentioned. For the data analysis psychophysics analysis and parametric statistics were used, through the Pearson correlation, linear regression and Student-t test. A clear linear correlation was found between the scales (r=0,97, p<0,05), the scales and oxygen uptake (CR10: r=0,90; VAS: r=0,90) and heart rate values (CR10: r=0,89; VAS: r=0,91). Precise assessment were also found irrespective from the scale used (n=0,99; r2=0,99). These results suggest that the physical magnitudes of VAS and Borg´s CR10 scales are highly correlated. Moreover, in both scales, the increase of the power, the heart rate and the oxygen uptaken corresponds to the increase of the subjective estimations of the participants in relation to the physical effort. These may indicate a clear interaction between the different variable present during the continuous dynamic physical exercise test.
50

"Comparação entre diferentes abordagens do problema de fluxo de potência ótimo utilizando o método de pontos interiores"

Lima, Aline Maria de 12 March 2004 (has links)
Neste trabalho, é apresentado o problema de fluxo de potência ótimo DC utilizando os modelos de fluxos em rede e o princípio do mínimo esforço. É apresentada também uma revisão dos métodos de pontos interiores e o mesmo é desenvolvido para um problema geral de programação linear. Em seguida, desenvolvemos os métodos de pontos interiores primal-dual e preditor-corretor para os modelos de fluxo de potência específicos estudados. Resultados numéricos de uma implementação em MATLAB são apresentados para sistemas testes do IEEE e sistemas reais, comparando o desempenho obtido pelas duas formulações. O método de pontos interiores se mostra bastante robusto convergindo rapidamente para todos casos testados. O modelo usando o princípio do mínimo esforço converge em menos iterações, mas a modelagem por fluxos em rede se mostra mais rápida, uma vez que suas iterações são mais baratas. / In this work, the optimal DC power flow problem using the network flow models, and the minimum effort principle are presented. Also is presented a review of the interior point methods and this method is developed for a generic linear programming problem. We developed the primal-dual and predictor-corrector versions of the interior point methods for the specific power flow models studied. Numerical results of a MATLAB implementation are presented for IEEE test systems and for real systems, confronting the performances achieved for both approaches. The interior point methods shows to be robust, achieving fast convergence in all instances tested. The minimum effort principle based model converges in fewer iterations, but the network flow model shows to be faster, since its iterations are cheaper.

Page generated in 0.0483 seconds