• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 10
  • 9
  • 8
  • 8
  • 4
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 476
  • 201
  • 145
  • 123
  • 105
  • 102
  • 98
  • 98
  • 89
  • 85
  • 68
  • 64
  • 63
  • 59
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Avaliação das valas de filtração como metodo de pos-tratamento de efluentes anaerobios

Natalin Junior, Osvaldo 12 November 2002 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T18:51:31Z (GMT). No. of bitstreams: 1 NatalinJunior_Osvaldo_M.pdf: 10529570 bytes, checksum: 7c739cc64315b4a69001530969db684c (MD5) Previous issue date: 2002 / Resumo: No presente trabalho de pesquisa foram estudadas três valas de filtração com 15 m de comprimento e 0,5 m de largura, revestidas com lona de PVC com 1,00 mm, com alturas da camada filtrante de areia igual a 0,25, 0,50 e 0,75 m, utilizando-se tubo de drenagem em PEAD - polietileno de alta densidade, com 0,10 m de diâmetro e instalados com inclinação de 1 :300. Estas receberam efluente de quatro filtros anaeróbios de fluxo ascendente com recheio em anéis de bambu e operando com TDH igual a 3 horas. As valas de filtração estavam localizadas na ETE-Graminha na cidade de Limeira, SP e foram operadas durante um período de 497 dias, dividido em cinco períodos que corresponderam a aplicação das seguintes taxas hidráulicas: 20, 25, 30, 35 e 40 Um2.dia. Os valores de pH no efluente dos filtros anaeróbios e na saída das três valas ficaram no intervalo entre 6,00 e 8,00 na média. Os melhores valores de remoção de DBOrotal foram obtidos na vala 0,75 m na taxa 20 Um2.dia (90,19%); para DQOtotal e fósforo a vala 0,50 m na taxa 40 Um2.dia foi a mais eficiente (95,35 e 94,71% respectivamente). A remoção de NTotal foi mais eficiente na vala 0,25 m na taxa 40 Um2.dia (70,17%). A vala 0,50 m na taxa 20 Um2.dia foi a mais eficiente na remoção de Coliforme Fecal (99,9955%) e a vala 0,75 m na taxa 30 Um2.dia foi a com melhor desempenho na remoção de e. coli (99,9959%). A remoção de Sólidos Suspensos Totais foi sempre superior a 80,72% nas valas. De uma maneira geral, o desempenho das valas de filtração como pós-tratamento de efluente anaeróbio foi eficiente na remoção de C, N e P com concentrações finais média, para todas as taxas, de 19,03, 25,68 e 1,92 mg/l respectivamente. Seu uso é uma alternativa viável como póstratamento de efluentes anaeróbios, compatível com as exigências da legislação brasileira e demonstrou durante todo a pesquisa ser de fácil operação / Abstract: For the research work herein were analyzed three filtration ditches with 15 m length and 0,5 m width, coated with PVC cloth 1,00 mm thickness, filtering sand layer with heights equal to 0,25, 0,50 and 0,75m using a PEAD draining pipe with 0,10 m diameter and installed with a slant of 1 :300. Those four anaerobic filters received uphill flow effluents filled with bamboo rings and working with 3 hours HDT. The filtration ditches were located at wastewater treatment works - Graminha in LimeiralSP/Brazil and operated for 497 days, split in five periods according to the following hydraulic rates: 20, 25, 30, 35, 40 Um2.day. The pH values of the anaerobic filters effluents and the three filtration ditches exits were between 6,00 and 8,00, as an average. The best BOD Total removal values were found in the filtration ditch 0,75m and the rate was 20 Um2.day (90,19%); for CDO total and phosphorus, the most efficient filtration ditch was the 0,50 m with a 40 Um2.day rate (95,35 and 94,71% respectively). The NTotal removal was more efficient in filtration ditch 0,25 m with a rate of 40Um2.dia (70, 17%). The filtration ditch 0,50 m with a rate of 20 Um2.dia was more effective in Total Coliform removal (99,9955%) and the filtration ditch 0,75 m with a rate of 30 Um2.day had the best performance in e. coli removal (99,9959%). The Total Suspended Solids removal rate have always been above 80,72% for the three filtration ditches analyzed. Generally speaking, the filtration ditch performance as anaerobic post treatment, was effective in C, N and P removal with medium final concentration for all rates applied (19,03, 25,68 and 1,92 mg/l respectively). Its use is a feasible alternative as anaerobic post treatment in accordance with Brazilian legislation and demonstrated an easy operation during the whole research period / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
92

Estudo da secagem de lodo de esgoto atraves da fritura de imersão

Silva, Daniela Pires da 16 December 2003 (has links)
Orientador: Osvaldir Pereira Taranto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-03T19:30:42Z (GMT). No. of bitstreams: 1 Silva_DanielaPiresda_D.pdf: 6927276 bytes, checksum: 3527a97cb43b68aac139be57535e6a03 (MD5) Previous issue date: 2003 / Resumo: O aumento da população e da industrialização tem resultado num aumento crescente no volume de resíduos gerados pelas atividades humanas. Parte considerável destes resíduos são os esgotos domésticos e o seu tratamento é uma necessidade básica de qualquer sociedade. O tratamento de esgotos é gerador de resíduos volumosos - lodo de esgoto - que devem ser posteriormente tratados devido a sua periculosidade e grande quantidade. Este trabalho teve o objetivo de tratar o lodo de esgoto, resíduo do tratamento de esgotos, através de secagem por fritura de imersão. O trabalho experimental foi realizado em três diferentes instituições, Unicamp (Br), Universidade de Queensland (Au) e Ecole des Mines (Fr). Os ensaios de fritura foram feitos em fritadores comerciais modificados com a adição de termopares, agitador e balança analítica. Foram secos alguns materiais como madeira, levedura de padaria e purê de batata como testes preliminares, além de amostras de lodo originárias das regiões das respectivas universidades envolvidas no trabalho. Foram obtidas curvas de variação de umidade com o tempo para os materiais citados e todas as curvas foram típicas de processos de secagem, com vantagem do processo de fritura ser bastante rápido. Durante a fritura do lodo, percebeu-se que, em relação aos parâmetros analisados: massa inicial, temperatura do óleo, tipo de óleo e geometria do material, o fator geometria foi o que mais influenciou a taxa de secagem, ao menos dentro das faixas estudadas para todas as variáveis. Além das curvas de secagem, outros dois parâmetros de importância foram analisados: a incorporação de óleo e o valor energético. O percentual de gordura no lodo passou de 0,18% para o lodo in natura à em média 30% para o lodo frito, dependendo do tempo de fritura. Este aumento está diretamente relacionado à perda de água durante a secagem. O poder calorifico do lodo frito aumenta com o tempo de fritura atingindo valores da ordem de 24MJ/kg após 600s de futura. Este valor energético é da ordem de bio-combustíveis como madeira e bagaço de cana. O processo de futura de imersão mostrou ter um grande potencial para secar materiais, em especial o lodo de esgoto, obtendo-se um lodo frito que possui um valor energético alto, valorizando a sua utilização como combustível / Abstract: The increase in the population and in industrialization resulted in an increase in the volume of wastes. Part of these wastes is the wastewater and its treatment is a basic necessity of any society. Wastewater treatment generates large amounts of residues sewage sludge - that must be treated as well due to its dangerous nature and its large quantities. The objective of this work was to treat the sewage sludge, residue of a wastewater treatment plant, using a fry-drying processo Experimental work was developed in three different institutions, Unicamp (Br), University of Queensland (Au) e Ecole des Mines (Fr). The frying experiments were carried out in commercial fryers modified with the addition of thermocouples, agitators and a analytical scale. Some materiaIs like wood, baker's yeast and potatoes were fried in preliminary tests, besides the sewage sludge from the different plant dose to where the institutions were located. Curves of variation of the moisture content with time were obtained for the cited materiaIs and all curves were typical of drying processes, with the advantage that the frying process is quite faster. During the frying of sewage sludge, it was verified that, in relation to the parameters: initial mass, oil temperature, oil type and geometry of the sample, the factor geometry was the most influent on the drying rate, at least within the range chose for the variables studied. Besides the drying curves, other two important parameters were analyzed: oil uptake and calorific value. The percentage of oil into the sewage sludge sample went from 0,18% (in natura) to a medi um value of 30% to the fried sludge, depending on frying time. This increase is directly related to the loss of water during drying. The calorific value of the samples increase with frying time, reaching values around 24MJ/kg after 600s of frying. This energetic value is in the same leveI as the value for known bio-combustibles as wood as sugarcane bagasse. The process of immersion frying showed a great potential to dry materials, in special sewage sludge, obtaining a product - fried sludge - with a high energetic content, increasing its value as a combustible / Doutorado / Engenharia de Processos / Doutor em Engenharia Química
93

Irrigação por infiltração com efluente de lagoa anaerobia em solo cultivado com milho (Zea mays L.)

Souza, Saulo Bruno Silveira e 15 December 2004 (has links)
Orientadores: Bruno Coraucci Filho, Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T12:54:43Z (GMT). No. of bitstreams: 1 Souza_SauloBrunoSilveirae_M.pdf: 2134454 bytes, checksum: bab490a3ce0807ae4e4dbc7afcf47a9a (MD5) Previous issue date: 2004 / Resumo: O reúso de efluentes domésticos anaeróbios na agricultura surge como alternativa de destino para o efluente tratado, visto que este possui características físico-químicas vantajosas para a agricultura, ao mesmo tempo em que possui concentrações que extrapolam os padrões de lançamento nos cursos de água. Neste estudo, o efluente anaeróbio foi utilizado para irrigação da cultura do milho, por meio de um sistema de sulcos rasos de infiltração, tendo como objetivo a determinação de taxas de aplicação, que sejam convenientes do ponto de vista sanitário e agronômico, à proteção dos aqüíferos subterrâneos e à produção de colheitas. Para tanto, foram investigadas três lâminas hídricas correspondentes às profundidades de irrigação de 0,20, 0,40 e 0,60 m, para os tratamentos irrigados com efluente, irrigados com água e fertilizantes, e, irrigados apenas com água, sem fertilização. O experimento foi conduzido durante três safras, empregando o cultivar AG 405 para as duas safras de verão, e, o cultivar BR 106 para a safra de inverno. Foram monitorados os líquidos lixiviados nas profundidades 0,25, 0,50 e 0,75 m para os tratamentos com esgoto e com água enriquecido com fertilizantes. A fertilidade do solo foi avaliada por meio de análises químicas de rotina, no final de cada safra, na linha de plantio, e, nos sulcos de irrigação. A produtividade da cultura foi avaliada pelo peso de grãos secos a 65o C; peso dos grãos secos a 105o C (13% de teor de água); e, peso de 1000 grãos a 13% de teor de água. Também, foram determinados os teores totais dos metais Cd, Cr, Cu, Ni, Zn, e, Pb, em folhas e grãos na segunda safra. Os resultados indicam que o reúso agrícola é, sem dúvida, vantajoso tanto no aspecto sanitário quanto no agronômico. As variáveis físico-químicas do efluente consideradas insatisfatórias no tratamento anaeróbio podem trazer benefícios ao sistema solo-planta. Para as três safras analisadas, a produção de grãos foi semelhante, tanto para o tratamento realizado com efluente quanto para o tratamento irrigado com água acrescido de fertilizantes, sendo que as parcelas irrigadas com lâmina de 0,40 m obtiveram as melhores produtividades. Na última safra, para esta lâmina, as parcelas irrigadas com efluente atingiram a produtividade de 6,2 ton ha-1, semelhante à produtividade das parcelas enriquecida com fertilizantes, 6,3 ton ha-1. No aspecto sanitário, observou-se remoção de matéria orgânica e fósforo. No material lixiviado, observou-se eficiência na remoção de DBO, variando de 77,8 a 99,5% em relação ao efluente anaeróbio. Em relação à DQO, a eficiência variou de 87,7 a 99,4%. Para o fósforo, sua concentração nas amostras teve redução em torno de 97,0% em relação ao efluente aplicado, demonstrando que ele foi imobilizado no solo e/ou absorvido pela cultura. O sistema apresentou boa eficiência do processo de nitrificação, sendo que as amostras lixiviadas sofreram redução da concentração de N-NH4+ de 99,0% em relação ao efluente. O nitrato foi lixiviado com mais intensidade após o estágio de desenvolvimento da planta, quando a necessidade hídrica e a demanda por nutrientes da cultura começa a reduzir-se. Em algumas etapas ao longo do ciclo da cultura, quando ocorreu aporte excessivo de nitrogênio, pode-se notar concentrações de nitrato no líquido lixiviado acima dos padrões de potabilidade, 10 mg L-1, tanto no tratamento com efluente, quanto com água enriquecido com fertilizantes. Ainda, os resultados obtidos para coliformes indicam que estes sobrevivem e estão presentes no solo, independente do tratamento. Para a E. coli notau-se redução da concentração na amostra da ordem de 3 unidades logarítmicas em relação à concentração no efluente aplicado. Em vista dos resultados obtidos na pesquisa, de maneira geral, conclui-se que o reúso é viável, desde que sejam tomadas precauções quanto aos impactos de origem sanitária, principalmente relacionada ao nitrato e aos coliformes / Abstract: The experiment was conducted around of a Sewage Treatment Plant located in Limeira city, São Paulo, Brazil. This research had the proposal to reuse the domestic effluent treated in an anaerobic lagoon, that present a BOD removal efficiency of 50%. The main objective was the determination of application rates of effluent in the soil according to sanitary and agronomic engineering practices. Three different rates were studied, corresponding to irrigation depths of 0.20, 0.40 and 0.60m. The study was carried out for three treatments, parcels irrigated with effluent, water plus fertilizer, and only water. Collectors were placed in the soil profile at 0.25, 0.50 and 0.75 m to extract the soil solution. The experiment was happened during three harvests, using the cultivar AG 405 for the two summer harvests, and, the cultivar BR 106 for the winter harvest. The fertility of the soil was verified through chemical analyses of routine, in the end of each harvest. The productivity of the culture was evaluated by the weight of dry grains to 65oC; by the weigh of dry grains to 13% of water; and, by the weigh from 1000 grains to 13% of water. Also, it was determined the total contents of the metals Cd, Cr, Cu, Ni, Zn, and, Pb, for the leaves and grains in the second harvest, and, for the grains in the third harvest. The results indicated that the agricultural reuse is, without a doubt, advantageous. The physiochemical characteristics, considered unsatisfactory in the anaerobic treatment, are advantageou to the system soil-plant. For the three harvests, the production of grains was practically the same, so much for the treatment with sewer and as for the treatment with water plus fertilizer. The irrigation depth of 0.40 m obtained the best productivity. In the last harvest, for this irrigation depth, the parcels irrigated with efluente had a productivity of 6.2 ton ha-1, while in the fertilizer parcels, 6.3 ton ha-1. In the sanitary aspect, the results indicated good removal of organic matter and phosphorus. The removal of DBO varied from 77.8 to 99.5% in relation to the anaerobic efluent. For DQO, the results varied from 87.7 to 99.4%. The P content was reduced around 97.0% in relation to the applied efluent, returning to its natural reservoir, the soil. The nitrification process was complete, with reduction of 99.0% in the N-NH4+ concentration when compared to efluent. Nitrate percolation occurs more frequently after the decreasing of the water and nutrient demand of the plants; in some cases, the concentrations of nitrate were high, so much for the treatment with sewage, as with mineral fertilization. It can be noticed concentrations of nitrate in the liquid collected above the water potability parameters, 10 mg L-1. Still, the results obtained for coliforms indicated that these microrganisms are present in the soil, independent of the treatment. For E. coli it was verified a reduction of the order of 3 logs in relation to the applied efluent. The reuse of anaerobic efluent in agricultural soils is viable, since precautions are taken to avoid the nitrate and coliforms contamination / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
94

Utilização de ácido tricloroisocianúrico (ATCI) na desinfecção de efluente sanitário de lagoa facultativa : avaliação da formação de trialometanos (TAMs) / Use of trichloroisocyanuric acid (ATCI) the disinfection of sanitary efluente from facultative pond : evaluation forming trihalomethanes (TAMs)

Albano, Paulo Vítor, 1975- 26 August 2018 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T17:38:42Z (GMT). No. of bitstreams: 1 Albano_PauloVitor_M.pdf: 3074541 bytes, checksum: 6b0f67ea4023640d18132645c437f8d0 (MD5) Previous issue date: 2014 / Resumo: A cloração é a tecnologia mais aplicada dentre os diversos processos utilizados para desinfecção das águas residuárias, devido ao custo reduzido e praticidade de aplicação, quando comparada com as demais técnicas. O inconveniente do uso deste tipo de técnica é a possibilidade de formação de subprodutos de desinfecção, dentro dos quais se destaca os trialometanos (TAMs). O presente trabalho avaliou a formação de TAMs em esgoto tratado de uma lagoa facultativa, submetido a um sistema de desinfecção por meio da utilização de ATCI. Avaliou também a eficiência deste sistema na desinfecção do efluente da lagoa facultativa. A avaliação consistiu de ensaio experimental, realizado em laboratório, para definição da dosagem e do tempo de contato; além do teste em escala real com a implantação do sistema de desinfecção na lagoa facultativa, situada no município de Itirapuã - SP. Os resultados obtidos demonstram que o sistema foi efetivo na desinfecção do efluente com uma aplicação de 10mg/L de cloro residual total e sem formação significativa de TAM, em média abaixo dos 3,0 µg/L, aparentemente devido à presença de concentrações elevadas de nitrogênio amoniacal (N-NH3) no efluente, da ordem de 43,0 mg/L. Conclui-se que a utilização do ATCI torna-se interessante devido à segurança, simplicidade das instalações e facilidade operacional / Abstract: Chlorination is the most technology applied among the different processes used for disinfection of wastewater, due to reduced cost and practicality of application compared with other techniques. The disadvantage of using this type of technique is the possibility of formation of disinfection byproducts within which stands trihalomethanes (TAMs). This study evaluated the formation of TAMs in treated sewage from a facultative pond, subjected to a disinfection system through the use of ATCI. Also evaluated the efficiency of this system for the disinfection of effluent from facultative pond. The evaluation consisted of an experimental test performed in the laboratory, to define the dosage and time of contact; beyond the full-scale test with the implementation of the disinfection system in the facultative pond, located in the municipality of Itirapuã - SP. The results demonstrated that the system was effective in disinfection of the effluent with an application of 10 mg / L of total chlorine residual and without significant formation of TAM on average below 3.0 g / L, apparently due to the presence of high concentrations of ammonia nitrogen (NH3-N) in the effluent of the order of 43.0 mg / L. We conclude that the use of ATCI becomes interesting due to security, simplicity of installation and operational ease / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
95

Materiais de tubulações utilizadas em sistemas de coleta e transporte de esgotos sanitários: estudo de caso da área norte de São Paulo. / Pipes materials used in sanitary sewer systems: case study of the northern area of São Paulo.

Bevilacqua, Nelson 06 October 2006 (has links)
Este trabalho descreve os diversos materiais que podem ser utilizados nas tubulações de sistemas de esgotos sanitários, apresenta suas principais características, a hidráulica das tubulações, principais fabricantes, aspectos construtivos, operação e manutenção e comentam-se as normas técnicas referentes a esses materiais. Os dados apresentados foram obtidos através de pesquisa na área norte de São Paulo cujo sistema é operado pela Sabesp, consultando-se as unidades funcionais de projeto, apoio técnico, operação, manutenção e obras da Sabesp. Destaca-se a preferência pelo uso das tubulações de PVC para a implantação e manutenção das ligações prediais e redes coletoras devido às vantagens de sua aplicação, tais como: facilidade de transporte e manuseio, maior produtividade, menos problemas operacionais, praticidade e segurança. Para coletores de maiores diâmetros e interceptores há preferência pelos tubos de PRFV, PVC e PEAD e pelo sistema de tubo de concreto cravado. Na escolha do melhor material a ser utilizado, deve-se considerar além das características dos esgotos, a resistência, a disponibilidade, a facilidade de transporte, e custos desse material . Deve-se, também se levar em conta, o método aplicado na construção e as condições locais da obra. Como principais conclusões, destaca-se a viabilidade econômica da utilização do PVC em relação ao tubo cerâmico nas obras de redes e ligações, e a tendência da utilização de PRFV e PEAD na implantação de novos coletores com diâmetro de 300 a 500mm. Recomenda-se a utilização de juntas elásticas nas tubulações cerâmicas e a especificação do tipo de material precedida de estudos amplos de viabilidade que considerem a sua vida útil, praticidade de aplicação, custos, aspectos ambientais, operação, manutenção, segurança e rapidez na implantação da obra. / This dissertation describes the various materials used in sanitary sewer systems, presents their main characteristics, pipeline hydraulics and manufacturers. It also features construction, operational and maintenance aspects for the different materials as well as the technical regulations concerning these materials. Data were collected in the Northern area of São Paulo, whose sewer system is operated by Sabesp, through research in the following functional units: project, technical support, operations, maintenance and construction. This study highlights the operation area\'s preference for PVC pipes for building and maintenance of sewage connections and sewers because its advantages such as: ease of transportation and handling, greater productivity, less operational problems, practicity and safety. For large diameter trunk sewers and interceptors, FRP (Fiberglass reinforced plastic), PVC (Polyvinyl chloride) and PE (Polyethylene) pipes and Jacking Pipe system are usually the choice. In the selection of the best material, one should consider the wastewater characteristics and the material resistance, availability, ease of transportation and cost. The construction methods and local conditions should also be taken into account in this process. In conclusion, this study stresses the economical viability of PVC pipes over ceramical pipes in sewers and connections, the tendency to use FRP and PE in new 300 - to 500- mm- diameter trunk sewers and recommendation for the use of elastic joints with ceramical pipes. Lastly, the specification of the type of material to be used should be preceded by broad viability studies that consider its required life, practicity, cost, environmental aspects, operational and maintenance aspects and safety in the building process.
96

Estudo de viroma em água de esgoto influente e efluente na estação de tratamento de esgoto norte em Brasília

Moriya, Nataly Mitie Natsume 01 March 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Biologia, Pós-Graduação em Biologia Microbiana, 2018. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T17:33:47Z No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T19:34:41Z (GMT) No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Made available in DSpace on 2018-07-20T19:34:41Z (GMT). No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) Previous issue date: 2018-07-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / A contaminação por patógenos humanos na água de esgoto é um assunto importante, principalmente em locais onde as condições de saneamento não são ideais. A tecnologia de Next Generation Sequencing (NGS) tem sido utilizada em diversos estudos metagenômicos virais (viromas). Além de descrever a diversidade genética, é uma ferramenta útil para analisar o viroma em amostras de esgoto. Apesar do interesse no tratamento de água, a cidade de Brasília não possuí um estudo de censo e informações focado na contaminação viral do Lago Paranoá. Com este propósito, os patógenos humanos astrovírus (HAstV), norovírus (NoV) e sapovírus (SaV) foram selecionados e investigados em amostras de água não-tratada (influente) e tratada (efluente) utilizando o NGS. Amostras de influente e efluente (de março, maio de 2016 e fevereiro de 2017) foram coletadas na estação de tratamento de água de esgoto em Brasília, Brasil. As amostras foram submetidas a processos de extração de RNA e as bibliotecas de cDNA foram sequenciadas através do Illumina HiSeq 2000, com a condição de 100 bases paired-end. Os reads foram trimados através do Trimmomatic e os contigs foram montados com os programas Megahit e Velvet. As sequências foram analisadas por tBLASTX e Megablast, respectivamente, contra o "RefSeq Virus" utilizando o software Geneious v.8.1. Os reads resultantes também foram enviados e analisados na plataforma online Kaiju. Os SaV foram detectados nas seis amostras sequenciadas, HAstV e NoV foram encontrados em todas as amostras, exceto no efluente de maio. Os resultados encontrados foram discutidos e comparados com estudos brasileiros e internacionais. / Contamination of human pathogen in wastewater is an important matter, especially where sanitation is not ideal condition. Next Generation Sequencing (NGS) has been applied in several viral metagenomes (viromes) studies. Besides describing gene diversity, it is a helpful tool to analyze virome in sewage water. Despite the interest in wastewater treatment, Brasilia city lacks a census study and information aiming to assess viral contamination in Paranoa lake. For this purpose, the human pathogens astrovirus (HAstV), norovirus (NoV) and sapovirus (SaV) were selected in untreated (influent) and treated (effluent) wastewater and investigated using NGS technology. Samples of influent and effluent stream (from March, May of 2016 and February of 2017) were collected at the treatment station of wastewater in Brasília, Brazil. Samples were submitted to RNA extraction process and the cDNA libraries were sequenced using Illumina HiSeq 2000 with the condition of 100 base paired-end. The NGS reads were trimmed by Trimmomatic and the contigs were assembled with Megahit and Velvet. The assembled contigs were analyzed by tBLASTX and Megablast, respectively, against RefSeq Virus using Geneious Software v.8.1. Resulted reads were also uploaded and analyzed on Kaiju online platform. SaV were detected in the six sequenced samples, HAstV and NoV were found in all samples except the May untreated water sample. The results found were discussed and compared with Brazilian and international studies.
97

Materiais de tubulações utilizadas em sistemas de coleta e transporte de esgotos sanitários: estudo de caso da área norte de São Paulo. / Pipes materials used in sanitary sewer systems: case study of the northern area of São Paulo.

Nelson Bevilacqua 06 October 2006 (has links)
Este trabalho descreve os diversos materiais que podem ser utilizados nas tubulações de sistemas de esgotos sanitários, apresenta suas principais características, a hidráulica das tubulações, principais fabricantes, aspectos construtivos, operação e manutenção e comentam-se as normas técnicas referentes a esses materiais. Os dados apresentados foram obtidos através de pesquisa na área norte de São Paulo cujo sistema é operado pela Sabesp, consultando-se as unidades funcionais de projeto, apoio técnico, operação, manutenção e obras da Sabesp. Destaca-se a preferência pelo uso das tubulações de PVC para a implantação e manutenção das ligações prediais e redes coletoras devido às vantagens de sua aplicação, tais como: facilidade de transporte e manuseio, maior produtividade, menos problemas operacionais, praticidade e segurança. Para coletores de maiores diâmetros e interceptores há preferência pelos tubos de PRFV, PVC e PEAD e pelo sistema de tubo de concreto cravado. Na escolha do melhor material a ser utilizado, deve-se considerar além das características dos esgotos, a resistência, a disponibilidade, a facilidade de transporte, e custos desse material . Deve-se, também se levar em conta, o método aplicado na construção e as condições locais da obra. Como principais conclusões, destaca-se a viabilidade econômica da utilização do PVC em relação ao tubo cerâmico nas obras de redes e ligações, e a tendência da utilização de PRFV e PEAD na implantação de novos coletores com diâmetro de 300 a 500mm. Recomenda-se a utilização de juntas elásticas nas tubulações cerâmicas e a especificação do tipo de material precedida de estudos amplos de viabilidade que considerem a sua vida útil, praticidade de aplicação, custos, aspectos ambientais, operação, manutenção, segurança e rapidez na implantação da obra. / This dissertation describes the various materials used in sanitary sewer systems, presents their main characteristics, pipeline hydraulics and manufacturers. It also features construction, operational and maintenance aspects for the different materials as well as the technical regulations concerning these materials. Data were collected in the Northern area of São Paulo, whose sewer system is operated by Sabesp, through research in the following functional units: project, technical support, operations, maintenance and construction. This study highlights the operation area\'s preference for PVC pipes for building and maintenance of sewage connections and sewers because its advantages such as: ease of transportation and handling, greater productivity, less operational problems, practicity and safety. For large diameter trunk sewers and interceptors, FRP (Fiberglass reinforced plastic), PVC (Polyvinyl chloride) and PE (Polyethylene) pipes and Jacking Pipe system are usually the choice. In the selection of the best material, one should consider the wastewater characteristics and the material resistance, availability, ease of transportation and cost. The construction methods and local conditions should also be taken into account in this process. In conclusion, this study stresses the economical viability of PVC pipes over ceramical pipes in sewers and connections, the tendency to use FRP and PE in new 300 - to 500- mm- diameter trunk sewers and recommendation for the use of elastic joints with ceramical pipes. Lastly, the specification of the type of material to be used should be preceded by broad viability studies that consider its required life, practicity, cost, environmental aspects, operational and maintenance aspects and safety in the building process.
98

Adenovirus e rotavirus como indicadores biologicos em aguas residuarias de esgotos sanitarios apos tratamento por processo anaerobio e disposição controlada no solo / Adenoviruses as biological indicators in watewater from sewage, before anaerobic process treatment and soil disposal

Martins, Sandra Soares 09 August 2018 (has links)
Orientador: Maria Silvia Viccari Gatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-09T22:09:52Z (GMT). No. of bitstreams: 1 Martins_SandraSoares_M.pdf: 1140484 bytes, checksum: de8846c9246eef9258a4b0d3953a88b6 (MD5) Previous issue date: 2006 / Resumo: O tratamento de esgoto sanitário em lagoa de decantação anaeróbia e disposição controlada de água residuária no solo é uma alternativa de baixo custo para o reuso de águas residuárias na agricultura. Nele, o esgoto sanitário é depositado em uma lagoa de decantação anaeróbia com retenção hidráulica de sete dias, após o que a água residuária é conduzida para rampa de solo franco argilo-arenoso, com cobertura vegetal de gramínia Cynodon sp, para disposição por escoamento superficial, seguindo-se sua infiltração e percolação. O objetivo desse trabalho foi verificar a eficiência desse sistema na eliminação e/ou inativação de adenovírus humanos (HAdV) e rotavírus (RV). Amostras de 1L de água residuária foram obtidas em quatro coletas, em intervalos de sete dias, na entrada do esgoto bruto (EB), no ponto de aplicação na rampa (0m) e nos pontos da sua superfície após 10, 20, 30, 35m e 40m. Sob a rampa, a 1m de profundidade e distantes 30m (30-1) e 35m (35 -1), dois pontos foram amostrados. Antes do ponto 0m, pontos de testemunha a 1m de profundidade e distantes 2m (T1) e 0,5m (T2) da rampa, e um ponto do lençol freático (LF) a 3m de profundidade, também foram coletados.As água residuárias foram concentradas de 1.000 a 5.000 vezes por filtração e eluição em membrana eletropositiva e ultracentrifugação. Nos eluatos obtidos, após extração de DNA, a presença de HAdV foi pesquisada por PCR e nested-PCR. Para a detecção de RV usou-se RT-PCR e duplo-semi- nested-PCR. Eluatos HAdV positivos foram inoculados em células HEp-2 e após até cinco passagens a presença de HAdV foi confirmada por PCR.. HAdV foram detectados em 29 das 35 amostras analisadas, sendo positivos todos os pontos de EB e da superfície da rampa. Em profundidade, sob a rampa, quatro amostras foram positivas, além de outras duas em T2 e uma em LF, o que demonstra a percolação desses vírus no solo com contaminação do LF. Quando testadas em células HEp-2, nas amostras do EB e dos pontos 0, 30, 35 e 40m a presença de vírions foi determinada, enquanto nos pontos 30-1m e LF os HAdV não foram infectivos. Esses resultados permitem concluir que o sistema não foi eficiente para remover e/ou inativar HAdV. Por outro lado, pode-se afirmar que os HAdV são indicadores virais adequados para esse sistema, desde que mantida a metodologia aqui empregada. Uma amostra de EB foi positiva para RV (genotipos G1 e G2), resultado esse que não permite qualquer conclusão. Para o reuso da água residuária advinda desse sistema impõe-se a associação de processos de desinfecção para a eliminação de HAdV / Abstract: Urban sewage treatment by an anaerobic process with overland flow system is a cheap alternative to reuse domestic effluents in agriculture. In this procedure, wastewater remains in an anaerobic pond for seven days, and then it is spilled from the top of a 40-meter extension slope covered with Tifton 85 (Cynodon sp) grass in order to surface flow and percolate until it reaches groundwater. The objective of this work is to determine if this procedure could be effective in removing and/or inactivating human adenoviruses (HAdV) and rotaviruses (RV) in a test unit in Limeira - SP, Brazil. Samples were collected every seven days from different spots in four sampling events totalizing one liter of wastewater. Sampling points were chosen at the raw sewage (EB), on the surface of the slope at 0, 10, 20, 30, 35 and 40 meters, and down one meter from the surface of the slope at the 30- and 35-meter points (30-1 and 35-1). Other points upslope were used at a distance of 2 meters (T1) and 0.5 meters (T2), beyond a 3-meter depth and 1-meter distant spot (LF). All samples were concentrated from a 1000 to 5000 times by filtration through electropositive microporous membrane followed by ultracentrifugation. HAdV detection was performed by both PCR and nested PCR. RV detection was accomplished by both RT-PCR and duplex semi-nested PCR. The positive samples for HAdV were inoculated in HEp-2 cells, and confirmation of the virions was performed by PCR. HAdV were detected in 29 of the 35 samples tested including in all samples both from the EB and from the surface of the slope. HAdV tested positive in the two T2, in one LF, and in the four samples underneath the slope. In HEp-2 cells HAdV virions were detected at the EB and at 0, 30, 35, and 40 meters on the surface of the slope. Spots 30-1 and LF were tested in HEp-2 cells, resulting negative to the presence of infective viral particles, although they tested HAdV positive. These results attest to the inefficiency of the proposed system of sewage treatment in removing and/or inactivating HAdV; however, maintaining the methodology used in this research, HAdV proves to be the appropriate viral indicator in this system. In relation to RV, no conclusions can be extracted since just one sample from the EB was RV-positive (G1 and G2 mixture). Finally, before reuse in agriculture, the effluents from the anaerobic pond should be disinfected to eliminate these viruses / Mestrado / Microbiologia / Mestre em Genética e Biologia Molecular
99

Influência do aporte de águas pluviais nos parâmetros da qualidade das águas residuárias da ETE Vista Verde.

Alexander Antonio Peres Gutiérrez Aguiñada 14 February 2008 (has links)
Para a coleta das águas residuárias e águas pluviais de uma comunidade e o transporte adequado para uma estação de tratamento de esgoto ou lançamento final, pode-se utilizar três tipos de sistema de esgotamento: sistema unitário, sistema separador parcial ou misto e sistema separador absoluto, sendo que no Brasil a legislação estabelece que seja adotado o sistema separador absoluto, concebido para coletar apenas as águas residuárias. Entretanto, na prática isto não ocorre, devido às ligações clandestinas de águas pluviais geradas pela falta de fiscalização e à ausência de redes de águas residuárias que atendam toda a população, gerando problemas na operação das Estações de Tratamento de Esgotos, por não suportarem o aumento da vazão afluente, ocorre a sobrecarga hidráulica e arraste de materiais sólidos das tubulações pluviais para Estações de Tratamento de Esgotos. O presente trabalho busca avaliar a qualidade dos esgotos combinados da Estação de Tratamento de Esgoto Vista Verde na cidade de São José dos Campos em períodos secos e chuvosos, a fim de analisar os impactos do aporte de águas pluviais, verificar se os mesmos se enquadram na RESOLUÇÃO DO CONAMA N 357 de 17 de Março de 2005 e fornecer propostas para mitigar os impactos gerados pelas tormentas na operação e no processo de tratamento de esgotos. Para isso contamos com a colaboração da SABESP que forneceu dados diários de vazão, oxigênio dissolvido, pH e sólidos sedimentáveis. Também foi realizado um trabalho de campo afim de conhecer o local e realizar coleta dos parâmetros (DBO, DQO, OD, pH, sólidos sedimentáveis e sólidos suspensos). Pode-se concluir que os efeitos da água pluvial nos parâmetros analisados influenciam na operação da ETE Vista Verde, mas não é a única responsável pela alteração na operação, pois a própria operação da ETE demonstra-se ineficiente mesmo em períodos de seca, tendo como outro responsável seu critério de operação; cabendo reavaliar os critérios de operação da mesma (aeradores). Os parâmetros DBO e OD não se enquadraram à legislação em vigor sendo que apenas o pH atendeu os padrões estabelecidos. Para solução do problema sugere-se uma reavaliação da operação dos aeradores, ou a implantação das técnicas alternativas lineares de drenagem urbana, que demonstram grandes eficiências de remoção da poluição contida no escoamento superficial.
100

Desenvolvimento e avaliação de uma miniestação ecoeficiente de tratamento de esgoto e reuso de águas, com sistemas regi strador queimador, para baixa vazões de biogás e cogeração de energia /

Godoy Junior, Ederaldo. January 2010 (has links)
Orientador: José Luz Silveira / Coorientador: Marcio Abud Marcelino / Banca: Agnelo Marotta Cassula / Banca: Celso Eduardo Tuna / Banca: José Rui Camargo / Banca: Sebastião Cardoso / Resumo: O presente trabalho trata do desenvolvimento, do processo construtivo, da implantação e da análise técnica, econômica e ambiental de uma miniETERA (miniestação ecoeficiente de tratamento de esgoto e reuso de águas), em PVC e concreto armado, associada a um sistema de cogeração de energia a biogás e a um sistema registrador e queimador de biogás para baixas vazões. A miniETERA é composta por três digestores anaeróbios de fluxo ascendente, em manto de lodo, do tipo UASB (upflow anaerobic slodge blancket) modificado, dispostos em série, formando cascata, seguido de um digestor híbrido aeróbio (com ar) e anóxio (sem ar na presença de nitrato). Para efeito do trabalho foi avaliada a eficiência dos reatores UASB, cuja redução média da DQO (demanda química de oxigênio) do efluente foi de 80,1%, sem a utilização de elementos eletromecânicos. O biogás produzido pelo sistema apresentou concentração média de 57,99% de metano no UASB I, devida à hidrólise, e de 80,45% de metano no UASB II, devida essencialmente à atividade metanogênica. O sistema compacto de cogeração de energia desenvolvido é composto por um motogerador de potência nominal de 5,5 kW a gasolina, convertido a biogás e/ou gás natural a baixa pressão (GNBP), acoplado a um trocador de calor gás/água, para a geração de energia elétrica e água quente. O cogerador compacto foi testado experimentalmente, utilizando biogás oriundo do tratamento anaeróbio de resíduo avícola, com uma porcentagem de 60% de metano; obteve-se uma potência útil de 2,6 kW e, no caso do uso de GNBP, a partir de GNV (gás natural veicular) despressurizado, obteve-se uma potência útil de 4,2 kW. O reuso de água foi feito por meio de sistema de fertirrigação de um bosque em 12 formação, com o efluente tratado. A análise técnica e econômica... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This paper deals with the development of the constructive process, and deployment of technical, economic and environmental dimensions of a EMSTWR (ecoefficient ministation of sewage treatment and water reuse), PVC and concrete, coupled with a cogeneration system to biogas energy system and a recorder and burner biogas for low flow. The Miniet is composed of two anaerobic digesters in upflow sludge blanket, UASB type (Upflow Anaerobic slodge blancket) modified, arranged in series forming cascade, followed by an aerobic digester Hybrid (air) and anóxio (no air in the presence nitrate) for the purpose of this study was to evaluate the efficiency of UASB reactors, whose average reduction of COD (chemical oxygen demand) of the effluent was 80.1% without the use of electromechanical components. The biogas produced by the system showed an average concentration of 57.99% methane in UASB I, due to hydrolysis, and 80.454% methane in UASB II, mainly due to methanogenic activity. The compact cogeneration power developed is composed of a motogenerator rated at 5.5 kW gasoline, or converted to biogas and natural gas at low pressure (NGLP) coupled to a heat exchanger gas / water for the generation electricity and warm water. The compact cogenerator was tested experimentally using biogas originating from anaerobic treatment of poultry manure, with a percentage of 60% methane, we obtained an output of 2.6 kW, and in case of using NGLP from NGV (Natural Gas Vehicle) depressurized, we obtained an output of 4.2 kW. Reuse of water was done through fertigation system in formation of a forest, with the treated effluent. A technical and economic analysis of EMSTWR compared with traditional systems of 14 sewage treatment, was interesting from the standpoint of environmental, energy and economic... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0973 seconds