• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 414
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 426
  • 232
  • 79
  • 78
  • 68
  • 60
  • 58
  • 58
  • 45
  • 41
  • 41
  • 41
  • 40
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Desenvolvimento de uma metodologia espectrofotométrica para determinação de chumbo em sangue.

Couto, Clara Macêdo January 1996 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2013-04-23T11:23:46Z No. of bitstreams: 1 Macedo C.pdf: 387637 bytes, checksum: 6df0bb17d013bb905008e47b9c3ca31b (MD5) / Made available in DSpace on 2013-04-23T11:23:46Z (GMT). No. of bitstreams: 1 Macedo C.pdf: 387637 bytes, checksum: 6df0bb17d013bb905008e47b9c3ca31b (MD5) Previous issue date: 1996 / No presente trabalho desenvolveu-se uma nova metodologia analítica para a determinação de chumbo em sangue através da espectrofotometria molecular. O método utiliza o quelante 2-(5-bromo-2-piridilazo)-5-dietilamonofenol (5-Br-PADAP). A composição da solução final de medida é a seguinte: 5-Br-PADAP 1,2x10-4 M; álcool etílico 50 % em volume; Triton X-100 0,15 %; ácido nítrico 0,5 M e hidróxido de amônia 0,5 M. As medidas espectrofotométricas foram realizadas a 575 nm, com abertura de fenda de 1 nm e cubeta com caminho ótico de 1 cm. A eliminação preliminar de interferências de metais foi obtida utilizando-se uma resina aniônica quaternária fortemente básica (AG1-X8, 200-400 mesh) empregando uma mistura a 90 % de metanol e 10 % v/v de ácido nítrico 5 N, em coluna de 3 cm de comprimento e diâmetro interno de 0,5 cm. O fluxo de eluição dos metais interferentes foi 0,5-0,6 mL/min e do chumbo, com ácido nítrico 1 N, 0,2 mL/min. As características analíticas da metodologia são: limite de quantificação (L.Q.) em 500 µL de amostra de sangue, 112 ppb; exatidão ao nível de 250 ppb ³ 96,5 %, as quais permitem uma ampla aplicação a estudos epidemiológicos de populações e controle de exposição profissional. / Salvador
42

Estudo sobre a proposta de metodologia para ensaios de determinação das concentrações e fósforo e clorofila "A" para emprego nos exames periciais de unidades de criminalística da Polícia Federal

Benites, Cassius de Melo January 2014 (has links)
Dissertação (mestrado profissional) - Universidade Federal de Santa Catarina, Centro de Ciências Biológicas, Programa de Pós-Graduação em Perícias Criminais Ambientais, Florianópolis, 2014 / Made available in DSpace on 2015-04-29T21:07:58Z (GMT). No. of bitstreams: 1 333111.pdf: 1554767 bytes, checksum: 117c765b544fed27d4cd27f837ee2120 (MD5) Previous issue date: 2014 / A investigação sobre a influência da variação das condições de preservação e de preparação de amostras subsidia a melhor confecção de um Procedimento Operacional Padrão (POP) na determinação da concentração dos analitos de interesse, no caso presente, o fósforo e a clorofila a. Neste estudo, foram investigadas as influências causadas pela variação da temperatura de preservação da amostra e pela variação do tempo entre a amostragem e o ensaio em laboratório sobre os resultados das concentrações dos analitos de interesse. A preparação das amostras foi feita por via-úmida em instalação do laboratório de química de um dos Setores Técnico Científicos da Polícia Federal. A metodologia foi elaborada com base em procedimentos operacionais padrões adotados em diferentes laboratórios de análise de água. A utilização do equipamento de espectrofotometria com arranjo de diodos - DAD permite a visualização de todo o espectro de absorção da amostra na faixa visível e Ultra Violeta - UV o que permite, principalmente nos estudos de cinética de reações, a visualização do comportamento da absorbância do analito e dos compostos interferentes nas diferentes regiões do espectro, facilitando a escolha do comprimento de onda adequado para a determinação da concentração do analito de interesse no âmbito do método utilizado naquele aparelho. De posse dos resultados, pôde-se concluir sobre a viabilidade do aproveitamento de amostras colhidas em campo quando estas estão sujeitas às variações de preservação ora investigadas. Os resultados indicaram que existe uma faixa linear de resposta de absorbância para concentrações até aproximadamente 0,8 mg/L de fósforo na amostra. Em ensaios de viabilidade de temporal de amostras coletadas em campo, observou-se que um decaimento significativo da concentração de fósforo em alíquotas não preservadas, indicando a adesão de formas orgânicas contendo o analito de interesse, o ortofosfato, nas paredes do recipiente ou sua precipitação em compostos orgânicos mais pesados. Foram obtidas boas recuperações do analito ortofosfato em amostras ambientais fortificadas, tanto em análise direta quanto após digestão com persulfato de potássio. Na análise quantitativa de clorofila a, com calibração por meio de modelamento matemático, obteve-se resultados que puderam ser utilizados na estimativa de índice de estado trófico de corpos d'água examinados.<br> / Abstract : Investigation of influence of the variation condition of the preparation and preservation of superficial water samples help to a better formulation of a Standard Operational Procedure in the determination of the concentration of the analytes of interest, this case, the Phosphorus and the Chlorophyll a. In this study, were investigated the influences caused by the variation of temperature and time between the event of sampling and laboratory procedures over the result of concentrations of interest analytes. The preparation of samples was done by wet procedures in a chemistry laboratory of one of the Regional Technical Scientific Sectors of the Brazilian Federal Police. The methodology was elaborated based in procedures adopted in different water study laboratories. The utilization of spectrophotometry equipment with diode-array detector - DAD allows a visualization of all the absorption spectrum of the sample in the visible and the ultra-violet band (UV-Vis). This analysis provides especially in the studies of the kinetics of reactions, to visualize the behaviour of absorbance of the analyte and other interferent compounds in the different regions of the spectrum, supporting the choice of the more apropriate wavelength to the determination of concentration of the analyte of interest among the method employed in that equipment. With the results, it could conclude about the viability of the usage of samples collected in field when those were subjected to variations of preservation now investigated. The results indicated that there is one linear response of absorbancy to concentrations up to 0,8 mg/L of phosphorus range in the sample. The assessment of the influence of time to sample collected on field showed a significant decrease of phosphorus concentrations in non-preserved aliquots, indicating the effect of a probable adhesion of organic forms containing the analyte of interest ? the orthophosphate, on the walls of the containing recipient or precipitated on heavier organic compounds. There were obtained good recovery results of orthophosphate on fortified environmental samples on direct analisys as well as after potassium persulphate digestion procedures. Quantitative analisys of Clorophyll a calibrated by a concentration mathematical equation resulted on data that could lead to the evaluation of a trophic state index of the streams examinated.
43

Avaliação de método espectrofotométrico comercial para determinação de trihalometanos em água de abastecimento humano / Evaluation of commercial espectrofotométrico method for determination of trihalometano in water of human supplying

Sampaio, Victor Cochrane Santiago 17 November 2010 (has links)
SAMPAIO, V. C. S. Avaliação de método espectrofotométrico comercial para determinação de trihalometanos em água de abastecimento humano. 2010. 141 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-04-29T14:01:42Z No. of bitstreams: 1 2010_dis_vcssampaio.pdf: 1974602 bytes, checksum: 7f70ce1403a7e89b5be16c6e8698cfc7 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-25T18:58:22Z (GMT) No. of bitstreams: 1 2010_dis_vcssampaio.pdf: 1974602 bytes, checksum: 7f70ce1403a7e89b5be16c6e8698cfc7 (MD5) / Made available in DSpace on 2016-05-25T18:58:22Z (GMT). No. of bitstreams: 1 2010_dis_vcssampaio.pdf: 1974602 bytes, checksum: 7f70ce1403a7e89b5be16c6e8698cfc7 (MD5) Previous issue date: 2010-11-17 / The formation of trihalomethanes in human water supply represents a big problem to the public health, since these compounds are suspected carcinogens. The technique referred for determination of trihalomethanes in water is gas chromatography, which uses an electron capture detector. This technique has some disadvantages that unfeasible the implantation in the water treatment plant. A spectrophotometry method developed by Hach® can assist the operation of a water treatment plant on the monitoring of trihalomethanes, since this analytical method has a lower cost, an immediate response by the results and is easy to implantation and operate when compared with gas chromatography. In this research, an evaluation of commercial spectrophotometry method was realized for some parameters of the Instituto Nacional de Metrologia, Normalização e Qualidade Industrial (INMETRO) and was divided into three stages. In the first stage, performed a test to make sure that the reducing agent neutralize any residual chlorine in the water. Sodium thiosulfate was added treated water of Gavião´s water treatment plant, to determine the concentration of “zero” mg L-1 in the determination of residual chlorine. The second stage consists in the implantation and operation of the analysis of trihalomethanes by gas chromatography. Two curves were performed using two different standards: a standard of chloroform and a standard of a mixture containing the four trihalomethanes, all with the same concentration. At this stage, all curves constructed showed a correlation coefficient in the range required by the rules of the INMETRO and of the method. The third step was the construction of curves by using again the two standards, but using the spectrophotometric method. Two curves of each standard by the same analyst and a curve of each standard of the other analyst were performed. With the data obtained, was studied the precision, accuracy, robustness, selectivity, linearity, working range and linear range. In addition, a standard addition test and a test for interference in the analysis of different matrices were performed. It was found that the method no had precision and accuracy. Small changes made in the analytical procedure caused change in the result, indicating lack of robustness of the analytical method, besides being extremely susceptible to random errors and possibly quantify other disinfection byproducts / A formação de trihalometanos na água de abastecimento humano representa um grande problema para a saúde pública, visto que esses compostos são suspeitos de serem carcinogênicos. A técnica referenciada para determinação de trihalometanos na água é a cromatografia gasosa, onde se utiliza o detector de captura de elétrons. Essa técnica apresenta algumas desvantagens que inviabilizam sua implantação em uma estação de tratamento de água (ETA). Um método espectrofotométrico desenvolvido pela empresa Hach® pode auxiliar a operação de uma ETA quanto ao monitoramento dos trihalometanos, pois esse método analítico tem menor custo, uma resposta imediata dos resultados e é de fácil implantação e operação quando se compara com a cromatografia gasosa. Nesta pesquisa, foi realizada uma avaliação do método espectrofotométrico comercial por alguns parâmetros do Instituto Nacional de Metrologia, Normalização e Qualidade Industrial (INMETRO) e foi dividida em três etapas. Na primeira etapa, realizou-se um teste para certificar-se que o agente redutor neutralizava todo o cloro residual presente na água. Foi adicionado tiossulfato de sódio na água final da ETA Gavião e determinou-se concentração de “zero” mg L-1 na determinação de cloro residual. A segunda etapa consistiu na implantação e operação da análise de trihalometanos por cromatografia gasosa. Foram realizadas duas curvas utilizando dois padrões diferentes: um padrão de clorofórmio e um padrão de uma mistura contendo os quatro trihalometanos, todos com a mesma concentração. Nessa etapa, todas as curvas construídas apresentaram um índice de correlação dentro da faixa exigida pelas normas do INMETRO e do método. A terceira etapa consistiu na construção de curvas utilizando novamente os dois padrões, porém utilizando a técnica espectrofotométrica. Foram realizadas duas curvas de cada padrão pelo mesmo analista e uma curva de cada padrão por outro analista. Com os dados obtidos, estudou-se a precisão, exatidão, robustez, seletividade, linearidade, faixa de trabalho e faixa linear. Além disso, foram realizados testes de adição de padrão e um teste para verificar a interferência de diferentes matrizes na análise. Constatou-se que o método não apresentou precisão, nem exatidão. Pequenas mudanças realizadas no procedimento analítico causaram alteração no resultado, indicando falta de robustez do método analítico, além de ser extremamente suscetível a erros aleatórios e, possivelmente, quantificar outros subprodutos da desinfecção
44

Desenvolvimento de sistemas de screening automatizados para determinação de sulfonamidas em mel e procedimento limpo para a quantificação de sulfaquinoxalina em medicamentos veterinários

Catelani, Tiago Augusto [UNESP] 15 January 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-01-15Bitstream added on 2014-06-13T20:18:56Z : No. of bitstreams: 1 catelani_ta_me_araiq_parcial.pdf: 56034 bytes, checksum: e0fec83762961fb2a290c883707606eb (MD5) Bitstreams deleted on 2014-11-14T12:16:58Z: catelani_ta_me_araiq_parcial.pdf,Bitstream added on 2014-11-14T12:17:45Z : No. of bitstreams: 1 000712502.pdf: 601891 bytes, checksum: 8df643c4b32a26b896742e14086cbcb1 (MD5) / A determinação de antibióticos tem sido assunto cada vez mais presente nos estudos de química, seja sua determinação para o controle de qualidade dos medicamentos ou determinação de resíduos em alimentos. O trabalho foi desenvolvido em duas etapas. A primeira parte do trabalho permitiu o desenvolvimento de uma metodologia simples, rápida e de baixo custo, onde se faz uso do procedimento de Análise por Injeção em Fluxo (FIA) com detecção espectrofotométrica para averiguar a presença de sulfaquinoxalina sódica em amostras de três tipos diferentes de medicamentos veterinários. A metodologia foi otimizada por planejamento de experimentos. O reagente cromogênico utilizado foi o pdimetilaminocinamaldeído (p-DAC) que na presença de ácido clorídrico (HCl) e o surfactante Dodecilsulfato de sódio (SDS), forma um produto colorido (l = 560 nm) com a compostos da classe das sulfonamidas (Base de Schiff). A segunda parte do permitiu o desenvolvimento de uma metodologia simples (método de screening), rápida, de baixo custo e acima de tudo limpa para determinação de sulfonamidas em amostras de mel, considerando preceitos da Química Verde e com isso reduzir ao máximo a geração de resíduos químicos e o uso de solventes orgânicos. O procedimento de análise que serviu como base para obtenção dos resultados foi a Análise por Injeção em Fluxo (FIA) com o uso de uma cela de longo caminho óptico (b = 100 cm) para detecção espectrofotométrica, permitindo assim um aumento significativo na sensibilidade do método de screening proposto. O sistema de detecção utilizado foi o espectrofotométrico na região do visível através das medidas de absorbâncias, em um comprimento de onda de l = 560 nm, do produto formado entre o analito (sulfaquinoxalina sódica – SQX, sulfadimetoxina – SDX e sulfatiazol - STZ) e... / The analytical determination of antibiotics has been subject increasingly present in chemistry studies, whether its determination to verify the presence medications (with the purpose of comparison with the label) or determination of residues in foods. The first part of this work presents the development of a simple, fast and low cost method, which makes use of the FIA procedure with UV detection to determine the presence of sodium sulphaquinoxaline in samples of three different types of veterinary medicines. The methodology was developed through statistical analysis, optimizing the chemical parameters (concentration) and physical values that provided the best absorbance at l = 560 nm. The chromogenic reagent used was p-DAC in the presence of HCl and SDS form a colored product with the compounds of the class of sulfonamides (Schiff base). The second part of the study aims to develop a simple methodology (screening method), rapid, inexpensive and above all clean for the determination of sulfonamides in honey samples, considering principles of green chemistry and thereby reduce the maximum generation chemical waste and the use of organic solvents. The analysis procedure that will serve as the basis for obtaining the results is the Flow Injection Analysis (FIA) using a cell along the optical path (b = 100 cm) for spectrophotometric detection, thereby allowing a significant increase in sensitivity of the screening method proposed. The detection system will be in the visible region spectrophotometer by measuring absorbance at a wavelength l = 560 nm, the product formed between the analyte (sodium sulphaquinoxaline - SQX, sulfadimethoxine - SDX and sulfathiazole - STZ) and chromogenic reagent (p-dimethylaminocinnamaldehyde - p-DAC), known as Schiff base. The interest in using this method... (Complete abstract click electronic access below)
45

Determinação enzimatica de salicilato com sistema de analise por injeção em fluxo

Vila, Marta Maria Duarte Carvalho 01 August 2018 (has links)
Orientadores : Matthieu Tubino, Graciliano de Oliveira Neto / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-01T20:44:30Z (GMT). No. of bitstreams: 1 Vila_MartaMariaDuarteCarvalho_D.pdf: 4268171 bytes, checksum: 3fd1575e0438b20246ab9f29aa876872 (MD5) Previous issue date: 2002 / Doutorado
46

Mecanização e automação de metodologias de analise quimica : instrumentação para destilação seguida de detecção por (ICP OES) e para extração liquido-solido e detecção por espectrometria no visivel

Capri Neto, Angelo 01 August 2018 (has links)
Orientador : Celio Pasquini / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-01T22:35:39Z (GMT). No. of bitstreams: 1 CapriNeto_Angelo_D.pdf: 11798702 bytes, checksum: 62737f9e8679365b09841e01a8401299 (MD5) Previous issue date: 2002 / Doutorado
47

Teores de isomeros trans em gorduras vegetais hidrogenadas avaliados por diferentes tecnicas instrumentais

Azevedo, Cristiane Hess de 25 July 2018 (has links)
Orientador: Lireny Ap. Guaraldo Gonçalves / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-25T12:36:09Z (GMT). No. of bitstreams: 1 Azevedo_CristianeHessde_M.pdf: 5053590 bytes, checksum: ef5694e665986cd307986fdab7d5a3b0 (MD5) Previous issue date: 1999 / Resumo: Na atualidade, óleos e gorduras são alimentos observados com muita atenção pelos consumidores, por terem relação direta com a saúde. As gorduras hidrogenadas nesse aspecto, merecem especial destaque pois são ingredientes importantes na elaboração de alimentos. Através de processos como a hidrogenação, é possível obter produtos gordurosos de consistência diferenciada e com melhor estabilidade oxidativa. Entretanto, esse percurso leva ao aparecimento de compostos indesejáveis, como por exemplo, os isômeros trans, gerando muita polêmica. Desta maneira, toma-se fundamental o monitoramento da formação desses compostos durante a hidrogenação, e sua quantificação nos produtos finais. Frente a essas informações, esse trabalho teve como objetivo aplicar as diferentes técnicas disponíveis na literatura para a quantificação de isômeros trans, comparando dados obtidos entre as técnicas em amostras reais. Foram utilizadas: cromatografia gasosa com 2 colunas cromatográficas de alta polaridade (SP-2340, CP-Sil 88) e a espectrofotometria infravermelho tradicional (AOCS Cd 14-95) e com uso de cartão IR-Card (3M). Na quantificação tendo como padrão amostras referência AOCS, o método de esterificação segundo HARTMAN & LAGO (1973) foi estudado e não produziu qualquer artefato que afetasse os resultados. Foram avaliadas 28 amostras comerciais de gorduras hidrogenadas brasileiras, de diferentes fornecedores, com teores de isômeros trans na faixa de 9 a 55%. Na comparação entre as colunas de alta polaridade, a fase estacionária com 100% cianopropilpolisiloxano (CP SIL 88) a 185°C apresentou boa eficiência, notadamente na separação de isômeros e 18:3t, que em outra coluna com 78% de cianopropilpolisiloxano (SP-2340) não foram detectadas. Entretanto a coluna SP-2340 apresentou melhor separação dos isômeros do C 18: 1 geométricos e posicionais. O método oficial para espectrofotometria infravermelho da AOCS, considerado como técnica padrão, levou à obtenção de resultados de isômeros trans com pequeno coeficiente de variação (0,13% a 1,94%). O uso de IR-cards apresentou tendência a subestimar os valores de isômeros trans, com coeficiente de variação entre 0,54% a 8%. A comparação das duas técnicas de infravermelho apresentou erros consideráveis na faixa de 1,19 a 29,91 %. Embora menos precisa, a técnica mais moderna baseada na quantificação de isômeros trans totais por cartões, apresenta-se como uma boa indicação se as gorduras hidrogenadas produzidas se enquadram em teores baixos, médios ou altos de isômeros. / Abstract: Nowadays, oils and fats are classes of food observed with more attention by the consumers, because their direct relationship with the health. The hydrogenated fats in that aspect, deserve special prominence because they are important ingredients in the elaboration of foods. By processes as the hydrogenation, it is possible to obtain fatty products of differentiated consistency and with better oxidative stability. However, these path lead to formation of undesirable components, for example, the isomeric trans, generating a lot of polemic. Therefore it becomes fundamental to inspect the formation of those components during the hydrogenation, and its quantification in the final products. Because those information, the aim of this work was to apply the different available techniques in the literature to the quantification of isomeric trans, comparing data obtained among the techniques in real samples. Gaseous chromatography was used with high polarity 2-chromatographic columns (SP-2340, CP-SiL 88), traditional infrared spectrophotometry (AOCS Cd 14-95) and with IR-Card (3M). In the quantification having as standard samples the AOCS reference, the esterification method according to HARTMAN & LAGO (1973) was studied and it did not produce any artifacts that affected the results. Twenty-eight commercial samples of brazilians hydrogenated fat from different vendors were tested andisomeric trans contents ranging from 9 to 55%. Comparing high polarity columns, the stationary phase with 100% cyanopropylpolisiloxano (CP-SIL 88) for 185°C and the 78% cyanopropylpolisiloxano column (SP-2340), the first one presented better efficiency, specially in the separation of isomeric C 18:3t, when the 78% cyanopropylpolisiloxano column was used, the isomers C 18:3t were not detected. However the SP-2340 column presented a better separation of the geometric and position isomeric of C 18:1t. The AOCS official method for infrared spectrophotometry - considered as standard technique in this work - lead to isomeric trans results with small variation coefficients (0,13% - 1,94%). The use of IR-Cards presented trends to underestimate the values of isomeric trans with variation coefficient in the range of 0,54 - 8%. However, the comparison of the two techniques presented considerable mistakes (1,19 - 29,91). Although less accurate, the more modem technique based on the quantification of total trans isomeric by IR-Card present itself as a good tool for industrial applications, because besides being innocuous and fast, this technique locates the valeus of these isomeric in ranges that lead to a good indication if the produced hydrogenated fats presents low, medium or high texts of isomeric. / Mestrado / Mestre em Tecnologia de Alimentos
48

Avaliação da rugosidade in vitro, e da formação de placa in situ, em superficies ceramicas submetidas a acabamento e polimento

Mendonça, Carlota Cristina Leite 02 February 1999 (has links)
Orientadores: Luis Alexandre Maffei Sartini Paulillo, Jaime Aparecido Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T16:13:13Z (GMT). No. of bitstreams: 1 Mendonca_CarlotaCristinaLeite_M.pdf: 4324145 bytes, checksum: efea2437e038489fe33c07cefd8919f8 (MD5) Previous issue date: 1999 / Resumo: Em situações de grandes destruições coronárias, restaurações do tipo "onlay/inlay" cerâmicas são indicadas, preenchendo satisfatoriamente os requisitos estética e função. Porém, ajustes oclusais devem ser realizados após a cimentação da peça, devido à natureza friável dessas restaurações, removendo incondicionalmente o "glaze" final nessa região, levando ao maior desgaste nos dentes naturais antagonistas e ao acúmulo de placa bacteriana. Para que essas situações venham a ser minimizadas, após ajustes oclusais, procedimentos de acabamento e polimento devem ser realizados. Assim, o objetivo deste trabalho foi avaliar ín vítro a rugosidade superficial de superfícies cerâmicas submetidas a procedimentos de acabamento e polimento, e o acúmulo de placa bacteriana in situ nessas mesmas superfícies. Os cilindros cerâmicos foram divididos nos grupos experimentais: (1) Sistema Kota; (2) Pasta diamantada; (3) Sistema Enhance; (4) Sistema Viking; (5) Ponta diamantada FF; (6) "glaze" final; (7) Ponta diamantada 2135. A rugosidade superficial foi avaliada através de rugosímetro (Ra), e o seu resultado mostrou que os procedimentos realizados não foram capazes de promover a lisura superficial do "glaze" final, e os melhores resultados foram apresentados pelos grupos 1,2 e 4. Para o estudo ín situ foram confeccionadas placas palatinas, e posicionadas sete amostras correspondendo aos grupos experimentais. Nove voluntários utilizaram os dispositivos intra-orais durante três dias por semana, num total de sete semanas. Os aparelhos foram imersos em sacarose 20%, oito vezes ao dia, para estimular a formação de placa bacteriana, e após os períodos de utilização, esta foi extraída e quantificada através de espectrofotômetro. Os resultados obtidos não demonstraram diferença estatísticamente significativa em relação ao acúmulo de placa bacteriana, entre os diferentes materiais de acabamento e polimento / Abstract: On extreme situations of coronal decay, toothcolored onlays and inlays are suggested to restore aesthetic and function. H oweve r, the friability of these restorations requests oclusal adjustments only afier cementation, certainly removing tme final glaze. The adjusted surfaces, if not well polished, can induce excessive wear of the opposing teeth and plaque retention. To minimize these responses, finishing and polishing procedures must be done. The aim of this study was to evaluate in vitro the ceramic surfaces roughness afier finishing and polishing, and in situ plaque acumulation on these surfaces. The specimens were divided' into seven groups: 1- Kota system, 2 Diamond paste, 3- Enhance system, 4- Viking~ system, 5- Diamond bur extra fine, 6 Final glaze, 7 - Diamond bur 2135. The surface roughness was evaluated with a perfilometer (Ra). The results showed that smoother surfaces are obtained with final glaze, followed by groups 1, 2 and 4. In the in situ experimemt, acrylic palatal appliances containing seven samples of ceramic blocks were used. Nine volunteers wore the intra oral models for three days per week, during seven weeks. During the experimental period, the appliances were immersed into 20% sucrose sOlution, eight times a day to induce plaque formation. The quantity of dental plaque formed on ceramic block$ was extracted and analysed by spectrophotometer. The results were statistically analysed and it was observed no significant differences between plaque formation and the finishing and polishing systems / Mestrado / Dentística / Mestre em Clínica Odontológica
49

Estudo Farmacognóstico e Validação de Metodologia Espectrofotométrica para Quantificação de Taninos nas Cascas De Schinus terebinthifolius Raddi

ALMEIDA, Camila Castelo Branco Rangel de 02 1900 (has links)
Submitted by Ramon Santana (ramon.souza@ufpe.br) on 2015-03-05T13:27:47Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Camila de Almeida.pdf: 2633484 bytes, checksum: e3bd3ae6409a1e24de5e770de33849c8 (MD5) / Made available in DSpace on 2015-03-05T13:27:47Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação Camila de Almeida.pdf: 2633484 bytes, checksum: e3bd3ae6409a1e24de5e770de33849c8 (MD5) Previous issue date: 2013-02 / Schinus terebinthifolius Raddi conhecida popularmente por aroeira e amplamente distribuída no Brasil, é utilizada na medicina tradicional por apresentar atividades biológicas comprovadas. Estas são geralmente atribuídas à presença dos polifenois e taninos existentes em sua composição. O objetivo deste trabalho foi realizar caracterização anatômica e histoquímica dos ramos e da casca do caule e validar metodologia para quantificação de taninos totais presentes na casca empregando o reagente de Folin-Ciocalteau (FC). O material vegetal foi coletado, identificado no herbário do IPA e a exsicata depositada sob o número 87539. O material foi preparado em lâminas semipermanentes seguindo os procedimentos usuais em anatomia vegetal. A folha é revestida por cutícula estriada, possui tricomas e estômatos anomocíticos apenas na face abaxial. O mesofilo é assimétrico em disposição dorsiventral com feixes vasculares colaterais. O caule apresenta tricomas tectores e glandulares, lenticela e raios unisseriados. O xilema é constituído por elementos de vasos todos com placas de perfuração simples, e pontuações dos tipos alternadas, reticuladas e escalariformes; podem apresentar apêndice nas extremidades ou não. Na casca observa-se bainha esclerenquimática completa, camadas de floema secundário e raios bisseriados heterogêneos. Em todas as partes estudadas foram verificados cristais de oxalato de cálcio e canais secretores, estes são ramificados na casca. Polifenois e taninos foram identificados em todas as partes analisadas. A metodologia para quantificação de taninos foi validada quanto aos parâmetros exigidos pela RE nº 899/2003. E demonstrou ser adequada para a espécie, apresentando especificidade e linearidade (R² = 0,9924). A recuperação apresentou valores entre 88,24 e 93,86%. O método também foi preciso através da repetitividade, determinada pelo desvio padrão relativo de seis extratos à concentração teste com TT = 3,29 μg/mL ± 0,132 (4,00%), e na precisão intermediária os fatores dias e analistas diferentes não apresentaram diferença estatisticamente significativa. Quanto à robustez a análise demonstrou que durante o experimento as amostras e o reagente FC devem ser protegidos da luz. Dessa forma, os resultados deste trabalho contribuem para a diagnose desta espécie fornecendo assim subsídios para a certificação de autenticidade da droga vegetal. Além de garantir segurança para a quantificação, por espectrofotometria, do teor de taninos totais na casca de Schinus terebinthifolius.
50

Construção de um expectrofotometro com transformada de Hadamard e sua aplicação na analise por injeção em fluxo

Poppi, Ronei Jesus, 1961- 18 July 2018 (has links)
Orientador : Celio Pasquini / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-18T11:43:56Z (GMT). No. of bitstreams: 1 Poppi_RoneiJesus_D.pdf: 7078750 bytes, checksum: 0b0bf0a5bb71eddfc079086d75cf4b66 (MD5) Previous issue date: 1993 / Doutorado

Page generated in 0.8466 seconds