Spelling suggestions: "subject:"fins"" "subject:"fits""
151 |
Propriedades mecânicas de fios de NiTi e CuNiTi com efeito memória de forma utilizados em tratamentos ortodônticos / Mechanical properties of NiTi and CuNiTi wires used in orthodontic treatmentMarco Abdo Gravina 21 September 2007 (has links)
Objetivou-se nessa pesquisa comparar oito tipos de fios de NiTi superelásticos e termoativos, de seis empresas comerciais (GAC, TP, ORMCO, MASEL, MORELLI e UNITEK) àqueles com adição de cobre (CuNiTi 27 e 35OC, ORMCO), observando se as propriedades mecânicas dos dois últimos justificariam sua escolha clínica. Para tal foram realizados ensaios de tração e microscopia eletrônica de varredura. Os ensaios de tração foram realizados em máquina de ensaios mecânicos da marca EMIC, modelo DL10000, de 10 toneladas de capacidade, no Instituto Militar de Engenharia (IME). A composição química e a topografia superficial dos fios foram determinadas através da microscopia eletrônica de varredura em microscópio da marca JEOL, modelo JSM-5800 LV com sistema de microanálise EDS (energy dispersive spectroscopy). Os resultados mostraram que, de forma geral, os fios de NiTi termoativados apresentaram cargas mais suaves de desativação em relação aos superelásticos. Entre os fios que apresentaram as cargas biologicamente mais adequadas de desativação estão os termoativados da GAC e da UNITEK. Entre os fios de NiTi superelásticos, os de CuNiTi 27C da ORMCO foram os que apresentaram as cargas mais suaves de desativação, sendo semelhantes, estatisticamente (ANOVA), às apresentadas pelos fios de NiTi termoativados da UNITEK para a deformação de 4%. Quando comparados os fios de CuNiTi a 27 e a 35C, observou-se que os primeiros apresentaram forças de desativação de, aproximadamente, 1/3 das apresentadas pelos últimos, para a deformação de 4%. Quando analisada a microscopia eletrônica de varredura de superfície, os fios de NiTi superelásticos que apresentaram melhores acabamentos foram os da MASEL e MORELLI e os que apresentaram os piores acabamentos foram os de NiTi e CuNiTi 27C da ORMCO. Entre os termoativados, todos apresentaram marcas e ranhuras de trefilação bastante visíveis, com características inadequadas em termos de topografia de superfície, sendo que os de CuNiTi 35C da ORMCO e os da UNITEK apresentaram os piores acabamentos de superfície graças à presença de microcavidades formadas devido aos arrancamento de partículas, possivelmente de NiTi4. Quando analisada a morfologia da região de fratura observou-se a presença de deformação plástica, e de microcavidades, características de fratura do tipo dúctil com redução macroscópica do diâmetro, para todos os grupos de fios NiTi e CuNiTi ensaiados, sendo que os de CuNiTi 27 C e os termoativados da UNITEK apresentaram as menores microcavidades e os melhores acabamentos à fratura. Concluiu-se que os fios de CuNiTi 35C, além de terem apresentado as maiores cargas de desativação entre os fios de NiTi termoativados, apresentaram os piores acabamentos das superfícies, o que não justificaria sua escolha como os primeiros fios para utilização clínica. / Leveling and aligning orthodontic wires must be able to generate light and continuous forces. Thus need to have high springback and flexibility. For this purpose it was suggested a variety of supereslatic and termoactivated Nickel-Titanium (NiTi) wires that may offer a load-deformation curve, in a constant plataform. Copper NiTi wires are presented as exhibiting better thermoactivating properties for optimum-forces system with better dental movement control. The aim of this study was to compare 8 NiTi superelastic and thermoactivated wires of six different brands (GAC, TP, ORMCO, MASEL, MORELLI and UNITEK) to Copper addicted wires (CuNiTi 270C and 350C, ORMCO) to verify if the mechanical properties of Copper NiTi would support its clinical use. Stress-strain tests were done in Engeneering Military Institute (IME-Brazil), through test machine (EMIC- DL 10000 model). Scanning electronic microscope with energy dispersive spectroscopy (JOEL, JSM-5800 LV model) was used to determine chemical composition and superficial topography of the wires. Results showed that, in general, thermoactivated NiTi wires exhibited lower deactivation loads when compared to NiTi superelastics. Among the thermoactivated, the GAC and UNITEK ones are the lighter ones. Among the superelastics, the Copper NiTi 270C (ORMCO) were the lighter ones, statistically similar (ANOVA) to thermoactivated NiTi from UNITEK, for 4% strain. Once Copper NiTi 270C showed deactivated loads 62% lower than Copper NiTi 350C , under 4% strain. As regard to Scanning Electronic Microscopy results for superelastic NiTi wires, better superficial burnishing were found for MASEL and MORELLI ones. On the other hand, the worst were ORMCO Superelastic NiTi and CuNiTi 270C. The thermoactivated ones were superficially visibly marked with inadequate superficial topography. Copper NiTi 350 C and UNITEK showed the worst burnishing among the thermoactivated wires, linked to microtags. It was concluded that CuNiTi 350 C showed the greatest deactivation loads and not favorable superficial burning.
|
152 |
Influência da transferência do ligamento coracoacromial no tratamento de lesões do ombro / Influence of the coracoacromial ligament transfer in the treatment of shoulder injuriesMenegaz, Gabriela Lima 31 March 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / The upper limbs are constituted by the shoulder, arm, forearm and hand. The shoulder
consists of the sternoclavicular, acromioclavicular and shoulder joints. The acromioclavicular
joint is stabilized by ligaments and deltoid and trapezius muscles. The ligaments which
constitute this joint are the acromioclavicular, coracoacromial and coracoclavicular, which is
divided into trapezoid and conoid. The joint can be injured due to the direct fall on shoulder
or on extended upper limb and are common in sports with hard contact. The
acromioclavicular dislocation is classified into different types and there are specific
treatments for each one. The Weaver-Dunn technique is one of the most common and
consists in removing the intact coracoacromial ligament of the acromion, followed by its
direct attachment to the structure of the clavicle. This technique has disadvantages when
compared with others that do not require the transfer of the ligament. This occurs because it
is an invasive procedure, require longer surgical time and require a longer period of healing.
In this study, the techniques of Weaver-Dunn and coracoclavicular sling were evaluated. In
both procedures, sutures are used to replace the coracoclavicular ligaments that have been
injured. The analysis of the influence of coracoacromial ligament transfer was performed
using three-dimensional models by the finite element method. Here is also investigated the
tensile strength of some commercial sutures. Sutures composed by polyblend, as Fiberwire®
and HiFi®, showed higher tensile strength than polyester sutures, as Ethibond®. In intact
acromioclavicular joint, considering the proposed conditions, the trapezoid ligament showed
higher stress values. The distance between the clavicle and the coracoid process showed
similar behavior among the techniques evaluated. Thus, considering the simplifications of the
models, it was concluded that there would not be a positive influence in the implementation
of the transfer of the coracoacromial ligament to stabilize the acromioclavicular joint. To
verify the results of this study, it is important the development of new numerical models and
clinical research related to surgical techniques assessed. / Os membros superiores são constituídos pelo ombro, o braço, o antebraço e a mão. O
ombro é composto pelas articulações esternoclavicular, acromioclavicular e do ombro. A
articulação acromioclavicular se estabiliza através dos ligamentos e dos músculos deltóide e
trapézio. Os ligamentos que constituem a articulação são o acromioclavicular, o
coracoacromial e os coracoclaviculares, trapezóide e conóide. As lesões mais comuns
ocorrem devido à queda sobre o ombro ou sobre o membro superior estendido, sendo
comuns em esportes de contato. A luxação acromioclavicular é classificada em diferentes
tipos e existem tratamentos específicos para cada um deles. A técnica de Weaver-Dunn é
uma das mais utilizadas e consiste na retirada do ligamento coracoacromial intacto do
acrômio, seguida pela sua fixação direta na estrutura da clavícula. Essa técnica apresenta
desvantagens em relação a outras que não necessitam da transferência do ligamento, por
ser um procedimento invasivo, demandar maior tempo cirúrgico e necessitar de um maior
período de cicatrização. Nesse estudo, foram avaliadas as técnicas de Weaver-Dunn e dos
amarrilhos coracoclaviculares. Em ambos os procedimentos, usam-se os fios de sutura para
substituir os ligamentos coracoclaviculares rompidos. Analisou-se a influência da
transferência do ligamento coracoacromial através de modelos tridimensionais de elementos
finitos. Além disso, verificou-se a resistência à tração de alguns fios de sutura comerciais.
Os fios constituídos de polimistura, como o FiberWire® e o HiFi®, apresentaram maiores
valores de resistência à tração do que os fios de poliéster, como o Ethibond®. Para as
condições propostas, o ligamento trapezóide apresentou os maiores níveis de tensão na
articulação acromiclavicular intacta. A distância entre a clavícula e o processo coracóide
apresentou comportamento semelhante entre as técnicas avaliadas. Assim, considerando as
simplificações dos modelos, conclui-se que não há influência positiva na realização da
transferência do ligamento coracoacromial para a estabilização da articulação
acromioclavicular. Para a comprovação dos resultados deste estudo, é importante a
realização de novas modelagens numéricas e pesquisas clínicas relacionadas com as
técnicas cirúrgicas abordadas. / Mestre em Engenharia Mecânica
|
153 |
Vazamentos de corrente e ineficiÃncia de transporte em nanoestruturas semicondutoras investigadas atravÃs de propagaÃÃo de pacotes de onda. / CURRENT LEAKAGE AND TRANSPORT INEFFICIENCY IN SEMICONDUCTOR NANOSTRUCTURES INVESTIGATED BY QUANTUM WAVE PACKETAriel Adorno de Sousa 08 May 2015 (has links)
CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / Os avanÃos nas tÃcnicas de crescimento tornaram possÃvel a fabricaÃÃo de estruturas semicondutoras quase-unidimensionais em escalas nanomÃtricas, chamadas pontos, fios, poÃos e anÃis quÃnticos. Interesse nessas estruturas tem crescido consideravelmente, nÃo sà devido Ãs suas possÃveis aplicaÃÃes em dispositivos eletrÃnicos e à sua manipulaÃÃo quÃmica fÃcil, mas tambÃm porque eles oferecem a possibilidade de explorar experimentalmente vÃrios aspectos de confinamento quÃntico, espalhamento e fenÃmenos de interferÃncia. Em particular, neste trabalho, investigamos as propriedades eletrÃnicas e de transporte em poÃos quÃnticos, fios e anÃis, cujas dimensÃes podem ser alcanÃados experimentalmente. Para isto, resolvemos a equaÃÃo de SchrÃdinger dependente do tempo utilizando o mÃtodo Split-operator em duas dimensÃes.
Nesta tese, abordamos quatro trabalhos, sendo o primeiro uma analogia ao Paradoxo de Braess para um sistema mesoscÃpico. Para isso, utilizamos um anel quÃntico com um canal adicional na regiÃo central, alinhado com os canais de entrada e saÃda. Este canal extra faz o papel do caminho adicional em uma rede de trÃfego na teoria dos jogos, similar ao caso do paradoxo de Braess. Calculamos as auto-energias e a evoluÃÃo temporal para o anel quÃntico. Surpreendentemente, o coeficiente de transmissÃo para algumas larguras do canal extra diminuiu, semelhante ao que acontece com redes de trÃfego, onde a presenÃa de uma via extra nÃo necessariamente melhora o fluxo total. Com a analise dos resultados obtidos, foi possÃvel determinar que neste sistema o paradoxo ocorre devido a efeitos de interferÃncia e de espalhamento quÃntico.
No segundo trabalho, foi feita uma extensÃo do primeiro, (i) aplicando-se um campo magnÃtico, onde foi possÃvel obter o efeito Aharonov-Bohm para pequenos valores do canal extra e controlar efeitos de interferÃncia responsÃveis pelo paradoxo mencionado, e (ii) fazendo tambÃm a aplicaÃÃo de um potencial que simula a ponta de um microscÃpio de forÃa atÃmica (AFM) interagindo com a amostra - este potencial à repulsivo e simula um possÃvel fechamento do caminho em que o pacote de onda se propaga. Assim, neste trabalho, realizamos uma contra-prova do primeiro, onde observamos que com o posicionamento da ponta do AFM sobre canal extra, se diminui o efeito de reduÃÃo de corrente devido ao paradoxo de Braess.
No terceiro trabalho, realizamos uma anÃlise de tunelamento entre dois fios quÃnticos separados por uma certa distÃncia e calculamos qual a menor distÃncia para qual ocorre tunelamento significativo nesse sistema eletrÃnico. Este trabalho à de fundamental importÃncia para o manufaturamento de dispositivos nanoestruturados, porque nos permite investigar qual a distÃncia mÃnima para a construÃÃo de um circuito eletrÃnico sem que haja interferÃncias nas transmissÃes das informaÃÃes.
No quarto e Ãltimo trabalho desta tese, investigamos a energia de ligaÃÃo do elÃtron-impureza em GaN/HfO2 para um poÃo quÃntico. Consideramos simultaneamente as contribuiÃÃes de todas as interaÃÃes das auto-energias devido ao descasamento das constantes dielÃtricas entre os materiais. Foram estudados poÃos largos e estreitos, comparando os resultados para diferentes posiÃÃes da impureza e a contribuiÃÃo da auto-energia para o sistema. / Advances in growth techniques have made possible the fabrication of quasi one-dimensional semiconductor structures on nanometric scales, called quantum dots, wires, wells and rings. Interest in these structures has grown considerably not only due to their possible applications in electronic devices and to their easy chemical manipulation, but also because they offer the possibility of experimentally exploring several aspects of quantum confinement, scattering and interference phenomena. In particular, in this work, we investigate the electronic and transport properties in quantum wells, wires and rings, whose dimensions can be achieved experimentally. For this purpose, we solve the time-dependent SchrÃdinger equation using the split-operator method in two dimensions.
We address four different problems: in the first one, the electronic transport properties of a mesoscopic branched out quantum ring are discussed in analogy to the Braess Paradox of game theory, which, in simple words, states that adding an extra path to a traffic network does not necessarily improves its overall flow. In this case, we consider a quantum ringindex{Quantum ring} with an extra channel in its central region, aligned with the input and output leads. This extra channel plays the role of an additional path in a similar way as the extra roads in the classical Braess paradox. Our results show that in this system, surprisingly the transmission coefficient decreases for some values of the extra channel width, similarly to the case of traffic networks in the original Braess problem. We demonstrate that such transmission reduction in our case originates from both quantum scattering and interference effects, and is closely related to recent experimental results in a similar mesoscopic system.
In the second work of this thesis, we extend the first system by considering different ring geometries, and by investigating the effects of an external perpendicular magnetic field and of obstructions to the electrons pathways on the transport properties of the system. For narrow widths of the extra channel, it is possible to observe Aharonov-Bohm oscillations in the transmission probability. More importantly, the Aharonov-Bohm phase acquired by the wave function in the presence of the magnetic field allows one to verify in which situations the transmission reduction induced by the extra channel is purely due to interference. We simulate a possible closure of one of the paths by applying a local electrostatic potential, which can be seen as a model for the charged tip of an atomic force microscope (AFM). We show that positioning the AFM tip in the extra channel suppresses the transmission reduction due to the Braess paradox, thus demonstrating that closing the extra path improves the overall transport properties of the system.
In the third work, we analyze the tunneling of wave packets between two semiconductor quantum wires separated by a short distance. We investigate the smallest distance at which a significant tunneling between the semiconduting wires still occur. This work is of fundamental importantance for the manufacturing of future nanostructured devices, since it provides information on the minimum reasonable distances between the electron channels in miniaturized electronic circuits, where quantum tunnelling and interference effects will start to play a major role.
In the last work of this thesis, we investigate the binding energy of the electron-impurity pair in a GaN/HfO2 quantum well. We consider simultaneously the contributions of all interactions in the self-energy due to the dielectric constant mismatch between materials. We investigate the electron-impurity bound states in quantum wells of several widths, and compared the results for different impurity positions.
|
154 |
Método para proteção dos dados contra falhas de comunicação em redes de sensores sem fios. / Method for data protection against communication failures in smart sensors networks.Rubens Ramires Sobrinho 30 November 2007 (has links)
Este trabalho apresenta o desenvolvimento de um método para garantir a proteção dos dados contra falhas de comunicação, em redes de sensores inteligentes sem fios. A rede sem fios foi empregada nos ensaios de modelos físicos reduzidos em centrífuga para estudar o comportamento das âncoras \"tartaruga\", utilizadas nas linhas de ancoragem de sistemas oceânicos para produção de óleo e gás em águas profundas. O emprego da tecnologia de redes de sensores sem fios tem aumentado em muitas áreas da sociedade, principalmente na engenharia. Dessa forma, muitos problemas estão sendo enfrentados e estudados pelos pesquisadores. Sobretudo no que diz respeito à interferência ambiental, relação de potência e alcance, integridade da informação, miniaturização dos dispositivos, autonomia de energia, limitação de algoritmos e vida útil. A inserção da tecnologia de redes de sensores inteligentes sem fios nos ensaios de modelos físicos reduzidos em centrífuga, além de ser inédita no Brasil, permitirá avanços significativos na determinação de parâmetros que, atualmente, são de difícil obtenção com tecnologias convencionais como os sistemas de aquisição de dados e controle que utilizam cabos e fios. Muitas vezes depara-se com a inconveniência do peso dos cabos e dificuldades de instalação dos dispositivos nos modelos, pela sua pouca portabilidade. / This work present a method development to guarantee of the integrity data in the wireless smart sensor networks, employed in centrifuge physical modeling tests of anchors used as fixing devices of deep water production oil and gas systems. The use of wireless smart sensor networks technology has been increasing in many engineering areas. In spite of this evidence, lots of problems are being faced and studied by the researchers, environmental interference, power and reach relations, integrity of the information, miniaturization of the devices, energy autonomy, algorithms and useful life. The use of the wireless smart sensor networks technology in the reduced physical models test in centrifuge, by first time in Brazil, will allow significant advances in the parameters determination. The conventional instrumentation presents inconvenience of the weight cables and difficulties of the devices in the models by limited portability.
|
155 |
Avaliação da deflexão elástica de fios ortodônticos de níquel-titânio, calibre 0,014 / Load-deflection study of caliber 0.014 nickel-titanium orthodontic wiresRenata Sathler-Zanda 03 July 2012 (has links)
PROPOSIÇÃO: O objetivo desta pesquisa foi apresentar a magnitude e a constância das forças liberadas por fios ortodônticos de níquel-titânio, usados para a correção dos apinhamentos dentários. Outro objetivo foi comparar os dois meios mais utilizados de avaliação da deflexão elástica destes fios: o teste de 3 pontos e o dispositivo de simulação clínica. MATERIAL E MÉTODOS: Foram avaliados 11 grupos de fios de liga predominantemente de níquel-titânio, calibre 0,014, de 6 marcas diferentes (Abzil convencional e termoativado; GAC convencional e termoativado; Morelli convencional e termoativado; Ormco CuNiTi; Orthometric convencional e termoativado e Orthosource convencional e termoativado), em teste de deflexão elástica, nas deflexões de 0,5; 1; 2 e 3mm. Uma máquina de ensaio universal INSTRON 3342, com célula de carga de 10N foi utilizada e, como protocolo, foi seguida a norma ISO 15.841. Para a análise estatística dos resultados foram utilizados os testes: Kolmogorov-Smirnov, para conferir se havia normalidade; teste t independente, para comparação dos resultados do teste de 3 pontos e dos resultados do dispositivo; e o teste ANOVA seguido do teste de Tukey, para comparações entre grupos. RESULTADOS: Houve diferença estatística entre os resultados gerados pelo teste de 3 pontos e os gerados pelo dispositivo. Por ser o teste indicado pela norma ISO citada, somente os resultados do teste de 3 pontos foram considerados. Todos os fios estudados apresentaram pseudoelasticidade em uma faixa de variação de força de até 40cN. Os grupos Abzil convencional, GAC convencional, Morelli termoativado, Ormco CuNiTi e Orthometric convencional apresentaram força dentro de uma faixa considerada ótima para a indução da movimentação dentária (50cN-100cN). Os fios termoativados liberaram forças mais leves que seus pares convencionais. CONCLUSÕES: Dentre os grupos estudados, aqueles que apresentaram pseudoelasticidade, forças dentro de uma faixa considerada ótima e homogeneidade de amostra, foram os grupos Morelli termoativado e Ormco CuNiTi. / OBJECTIVE: The purpose of this study was to present the magnitude and the constancy of the forces released by nickel-titanium orthodontic wires, used to treat dental crowding. Another purpose was to compare the most usual types of bending tests used to evaluate these wires: 3-point test and clinical simulation device. MATERIAL AND METHODS: Eleven groups of orthodontic nickel-titanium wires, caliber 0.014, of 6 different brands (Abzil conventional and heat-activated; GAC conventional and heat-activated; Morelli conventional and heat-activated; Ormco CuNiTi; Orthometric conventional and heat-activated and Orthosource conventional and heat-activated) were tested by bending test, at deflections of 0.5; 1; 2 and 3mm. A universal testing machine INSTRON 3342 with a 10N load cell was used and, in order to standardize the tests, the ISO 15.841 regulation was followed. Statistical analysis was performed using the subsequent tests: Kolmogorov-Smirnov to verify normality; independent t test to compare the results of the 3-point test and the results derived from the device, and ANOVA followed by the Tukey test for intergroup comparisons. RESULTS: There were significant differences between the results of the 3-point test and the device. As indicated by the ISO regulation, only the results from the 3-point bending test were considered. All groups were classified as pseudoelastic, within a load range of 40cN, at maximum. The groups Abzil conventional, GAC conventional, Morelli heat-activated, Ormco CuNiTi and Orthometric conventional released load within optimum range (50cN-100cN). Heatactivated wires released lower load compared to conventional wire of the same brand. CONCLUSIONS: Among the groups evaluated those that presented pseudoelasticity, load within a range considered optimal, in a homogeneous manner, were Morelli heat-activated and Ormco CuNiTi.
|
156 |
Estudo comparativo entre dois métodos de tratamento da lesão do ligamento cruzado posterior por avulsão óssea na tíbia : amarrilho artroscópico e fixação com parafuso por via posterior aberta / Comparative study between two methods of treatment of tibial posterior cruciate ligament bony avulsion: arthroscopic suture and screw fixation using open posterior approach.Sasaki, Sandra Umeda 15 December 2003 (has links)
Atualmente, os bons resultados na lesão do ligamento cruzado posterior por avulsão óssea na tíbia associam-se ao tratamento cirúrgico e precoce. A técnica convencional é a fixação com parafuso pela via de acesso posterior do joelho, com abordagem direta das estruturas vasculares e nervosas da região. Neste estudo experimental em 20 joelhos de cadáveres, buscamos apresentar uma alternativa com amarrilho por via artroscópica, comparando-o com a técnica convencional, através da inspeção direta e de testes biomecânicos. Houve falha na fixação de apenas um exemplar de cada método e medidas de deslocamento tibial posterior (p=0,23) e rigidez média (p=0,28) sem diferenças significativas entre as duas técnicas. Concluímos ser o amarrilho artroscópico viável e uma alternativa no tratamento desta lesão. / Nowadays, good results on the management of posterior cruciate ligament bony avulsion of the tibia are associated with early surgical repair. The usual method of treatment is the open posterior approach with screw fixation, wich requires popliteal neurovascular bundle direct manipulation. This study presents a new arthroscopic suture and compares it with the conventional technique, using biomechanical tests and direct inspection in cadaveric specimens (20 knees). On both methods there was a fixation fail in one knee. The analisys of tibial posterior displacement (p=0,23) and stiffness (p=0,20) were similar for the two methods. The Arthroscopic suture presented is an effective reattachment method for this fracture pattern.
|
157 |
Trabalhos e estudos sobre a cultura de plantas produtoras de fios no Brasil colôniaAlves, Izabel Cristina 17 October 2007 (has links)
Made available in DSpace on 2016-04-28T14:16:30Z (GMT). No. of bitstreams: 1
Izabel Cristina Alves.pdf: 377405 bytes, checksum: 2e61fb86f7e92f75ea8bbae58f831cdd (MD5)
Previous issue date: 2007-10-17 / Secretaria da Educação do Estado de São Paulo / The dissertation goal is to point out and analyze Portugal actions for agricultural incentive on Brazil, most specifically the culture of plants that would turn into threads that could substitute linen hemp on late 17th and early 18th Centuries. These actions were based in a new way to understand nature, deeply marked by whole restoration plans that aimed Portugal's economic development. Shall be shown relevant authors which dedicated studies about such plants whose ideas contributed in a new position and manners to observe Nature through a scientific agriculture turned into a new methodology of observation and experimentation, yet these changes had not been enough for complete agricultural technique and culture developments. Still on context will be presented difficulties faced by settlers observed through research on original documents / O objetivo desta dissertação é apontar e analisar as ações de Portugal de
incentivo à agricultura no Brasil, mais especificamente sobre a cultura das plantas
que se poderiam fabricar fios e que poderiam substituir o linho cânhamo, em finais
do século XVIII e início do XIX. Essas ações estavam baseadas em uma nova forma
de se compreender a natureza, e eram marcadas profundamente pelo conjunto de
reformas que visavam o desenvolvimento econômico de Portugal. Serão
apresentados autores, que se dedicaram aos estudos dessas plantas, cujas idéias
contribuíram na formação de novas posturas e modos de se olhar a natureza através
de uma agricultura científica, voltada para uma nova metodologia de observação e
experimentação, ainda que essas mudanças não tenham sido suficientes para o
total desenvolvimento dessas culturas e de técnicas agrícolas. Ainda neste contexto
apresentaremos as dificuldades enfrentadas pelos colonos que foram observadas
através da pesquisa em documentos originais
|
158 |
Estudo comparativo entre dois métodos de tratamento da lesão do ligamento cruzado posterior por avulsão óssea na tíbia : amarrilho artroscópico e fixação com parafuso por via posterior aberta / Comparative study between two methods of treatment of tibial posterior cruciate ligament bony avulsion: arthroscopic suture and screw fixation using open posterior approach.Sandra Umeda Sasaki 15 December 2003 (has links)
Atualmente, os bons resultados na lesão do ligamento cruzado posterior por avulsão óssea na tíbia associam-se ao tratamento cirúrgico e precoce. A técnica convencional é a fixação com parafuso pela via de acesso posterior do joelho, com abordagem direta das estruturas vasculares e nervosas da região. Neste estudo experimental em 20 joelhos de cadáveres, buscamos apresentar uma alternativa com amarrilho por via artroscópica, comparando-o com a técnica convencional, através da inspeção direta e de testes biomecânicos. Houve falha na fixação de apenas um exemplar de cada método e medidas de deslocamento tibial posterior (p=0,23) e rigidez média (p=0,28) sem diferenças significativas entre as duas técnicas. Concluímos ser o amarrilho artroscópico viável e uma alternativa no tratamento desta lesão. / Nowadays, good results on the management of posterior cruciate ligament bony avulsion of the tibia are associated with early surgical repair. The usual method of treatment is the open posterior approach with screw fixation, wich requires popliteal neurovascular bundle direct manipulation. This study presents a new arthroscopic suture and compares it with the conventional technique, using biomechanical tests and direct inspection in cadaveric specimens (20 knees). On both methods there was a fixation fail in one knee. The analisys of tibial posterior displacement (p=0,23) and stiffness (p=0,20) were similar for the two methods. The Arthroscopic suture presented is an effective reattachment method for this fracture pattern.
|
Page generated in 0.0614 seconds