Spelling suggestions: "subject:"fins"" "subject:"fits""
111 |
Empacotamento de fios e teoria do campo conforme em 2DSilva, Tiago Anselmo da 31 January 2013 (has links)
Submitted by Sandra Maria Neri Santiago (sandra.neri@ufpe.br) on 2016-03-07T19:42:45Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
DISSERTAÇÃO versão finalt.pdf: 2479188 bytes, checksum: 40682d874a9a13182595ec8c40992750 (MD5) / Made available in DSpace on 2016-03-07T19:42:45Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
DISSERTAÇÃO versão finalt.pdf: 2479188 bytes, checksum: 40682d874a9a13182595ec8c40992750 (MD5)
Previous issue date: 2013 / Neste trabalho resumimos o estudo do empacotamento de fios em uma região bidimensional planar. Abordamos o problema de um ponto de vista teórico, usando técnicas de campo conforme, e propriedades de escala do modelo, no regime de empacotamento-rígido, são derivadas, de sorte que os expoentes críticos para a energia elástica e para o número de laços da conformação são obtidos. Os resultados apresentam razoável concordância com dados advindos de experimentos e simulações. Também esboçamos uma analogia entre esse sistema e gravitação em duas dimensões, via gravitação de Liouville. / In this work we summarize the study of the packaging of wire in a planar two-dimensional region. We approach the problem from a theoretical point of view, using techniques of conformal field, and scaling properties of the model, in the tight-packing configuration, are derived, so that the critical exponents for the elastic energy and the number of loops of the conformation are obtained. The results show reasonable agreement with data coming from experiments and simulations. We also outline an analogy between this system and gravitation in two dimensions, via Liouville gravity.
|
112 |
Avaliação in vitro da força de atrito entre braquetes e fios ortodonticos na distalização do canino superior pela Tecnica de Força Direcional Seqüencial de Tweed-Merrifield / Evaluation of frictional forces in vitro between brackets and orthodontic wires in upper cusp distalization according to the Tweed-Merrifield Sequential Directional Force TechniqueKuramae, Mayury 21 June 2006 (has links)
Orientador: Maria Beatriz Borges de Araujo Magnani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-07T01:50:59Z (GMT). No. of bitstreams: 1
Kuramae_Mayury_D.pdf: 15126221 bytes, checksum: 69a444f9af9fdfb714e7271ab940c8fb (MD5)
Previous issue date: 2006 / Resumo: O objetivo desse estudo foi avaliar in vitro a força de atrito gerada na mecânica de distalização do canino superior pelo uso do gancho ¿J¿ na Técnica da Força Direcional Seqüencial de Tweed-Merrifield, de acordo com as variáveis: tipo e marcas dos braquetes; espessura e marcas dos fios; técnica de amarração e análise das superfícies dos fios e braquetes em microscopia eletrônica de varredura, microscopia de força atômica, além de rugosímetro. Foram utilizados 192 braquetes Edgewise de aço inoxidável de dois tipos e duas marcas comerciais e duas marcas de fios ortodônticos (Morelli, Sorocaba, São Paulo, Brasil e GAC, Central Islip, Nova Iorque, EUA) de aço inoxidável em quatro espessuras, amarrados por ligadura metálica e elastomérica em meio seco e à temperatura ambiente. Foi utilizada uma placa de acrílico retangular simulando um segmento de aparelho fixo composto por quatro braquetes duplos. Cada fio a ser testado teve suas extremidades dobradas justas aos braquetes terminais para que não deslizasse na canaleta e foi amarrado aos braquetes com ligadura de aço inoxidável. A placa de acrílico juntamente com o segmento do fio montado foi fixada no mordente da base da máquina de ensaio universal Instron 4411 (Instron Ltd., High Wycombe, Bucks, Reino Unido) de maneira a ficar posicionada em 45° em relação ao solo, o que foi realizado com o auxílio do esquadro, simulando a angulação do aparelho extrabucal gancho ¿J¿ com o plano oclusal, durante a mecânica de distalização do canino superior. O braquete foi puxado a velocidade de 0,5mm/minuto através do segmento do fio por uma distância de 5mm. Os testes foram repetidos três vezes, trocando-se a combinação braquete/fio a ser testada para cada três grupos. Os valores médios foram obtidos e a força de atrito foi calculada. Após o recorte das canaletas dos braquetes e limpeza dos fios e braquetes, esses foram analisados em microscopia eletrônica de varredura e de força atômica. Além disso, sobre a superfície dos fios foi efetuada a leitura da rugosidade de superfície em micrometros. Os dados foram submetidos à Análise de Variância e ao teste de Tukey (5%). Concluiu-se que: os braquetes duplos proporcionaram maior atrito do que os braquetes simples; os braquetes e fios da marca Morelli proporcionaram maior atrito do que os da GAC; quanto maior a espessura dos fios, maior foi o atrito; a técnica de amarração que gerou maior atrito foi com ligadura elástica quando comparada à ligadura de aço inoxidável; a rugosidade do fio diminuiu com o uso em alguns casos e os fios da marca GAC apresentaram qualitativamente lisura de superfície superior ao da marca Morelli / Abstract: This study aimed to evaluate in vitro frictional forces that result from upper cusp distalization due to using the J-Hook, according to the Tweed-Merrifield Sequential Directional Force technique; variables were: bracket type and manufacturer, wire diameter and manufacturer, ligation method and microscopic surface analysis of brackets and wires. One hundred and ninety-two stainless steel Edgewise brackets, of two different types and manufacturers were used, ligated to orthodontic wires of four diameters and two manufacturers (Morelli, Sorocaba, São Paulo, Brazil and GAC, Central Islip, New York, USA) by means of metallic and elastomeric ligatures, at extraoral environment and ambient temperature. A rectangular acrylic plate was manufactured, imitating a fixed appliance section of four double brackets. The ends of each wire were tightly bended to the terminal brackets, in order to eliminate sliding, and were fixed to the brackets by stainless steel ligatures. Each sample, comprising the acrylic plate, as well as the bracket and wire section, was fixed unto a Instron 4411 testing machine (Instron Ltd., High Wycombe, Bucks, United Kingdom), so that each of them was at a 45º inclination, relative to the horizontal plane, thus imitating the extraoral position of the J-hook, relative to the occlusal plane, during upper cusp distalization. The bracket was pulled for 5mm sliding at a speed of 0.5mm/minute. Tests were performed other three times, each for a different bracket/wire combination, over the three groups. The mean values were obtained and frictional forces were calculated. After cutting bracket slots and cleaning wires and brackets, these were analyzed by scanning electron and atomic force microscopy. Also, surface rugosity, in micrometers, was evaluated. Data underwent Variance analysis and Tukey test (5%). Final observations were: twin brackets provide greater frictional forces; brackets and wires manufactured by Morelli showed greater frictional forces than those by GAC; the larger the wire diameter, the greater the frictional forces; elastomeric ligatures resulted in greater friction than stainless steel ligatures; usage made the wires less roughness just in some cases, and GAC manufactured wires presented greater surface smoothness than those by Morelli / Doutorado / Ortodontia / Doutor em Radiologia Odontológica
|
113 |
Prorpiedades de transportes em fios e poÃos quÃnticos. / Transport Properties of Quantum Wells and Quantum WiresFrancisco FlorÃncio Batista JÃnior 21 July 2009 (has links)
Materiais semicondutores sÃo os principais responsÃveis pelo grande crescimento da indÃstria eletrÃnica e pelo surgimento de novas tecnologias. A criaÃÃo de heteroestruturas possibilitou um grande impulso à fÃsica do estado sÃlido. Atualmente, o estudo de semicondutores està concentrado em sistemas de dimensionalidade reduzida, como os poÃos, fios, pontos e aneis quÃnticos. Neste trabalho, investigamos as propriedades de transporte em fios quÃnticos heteroestruturados de barreira dupla e em sistemas bidimensionais de barreira simples e dupla.
Iniciamos com o cÃlculo da energia do confinamento radial no fio
quÃntico InAs/InP de barreira dupla. Usamos um modelo de fio cilÃndrico com e sem interfaces graduais. Calculamos as transmissÃes atravÃs das barreiras e estudamos o comportamento das mesmas variando a largura das barreiras, a distÃncia entre elas e o raio do fio. Futuramente utilizaremos estes resultados para o cÃlculo da corrente elÃtrica atravÃs do dispositivo.
TambÃm investigamos as propriedades de transporte em sistemas bidimensionais com potencial de auto-energia. Utilizamos heteroestruturas formadas por Si/SiO2 e Si/HfO2. Sendo as constantes dielÃtricas dos Ãxidos diferentes do silÃcio, resolvemos a equaÃÃo de Poisson com epsilon dependente de z. Expandimos o potencial em uma sÃrie de Fourier-Bessel, encontrando, por fim, o potencial imagem para as barreiras.
Calculamos a corrente elÃtrica atravÃs deste potencial em funÃÃo da voltagem, variando a temperatura, a distÃncia entre as barreiras. TambÃm levamos em conta as interfaces graduais para o caso de barreira simples. / Semiconductor materials are responsible for the large development in electronic industry, what made it possible the creation of new devices. The heterostructures gave a large impulse to the solid-state physics. Semiconductors study is nowadays concentrated in the low-dimensional systems, as quantum wells, quantum wires, quantum dots and
quantum rings. In this work, we investigate the transport properties of heterostructured quantum wires of double barrier.
We begin with calculation of radial confinement energy in a quantum wire InAs/InP of double barrier. We use a cylindrical model of wire with gradual and abrupt nterfaces.
Transmission coefficients are calculated. We study its behavior varying barriers width, distance between them and the wire radius. In the future, we will use these results to
calculate electric current through the device.
We also investigate transport properties of bidimensional systems with self-energy potential. We use heterostructures of Si/SiO2 and Si/HfO2. We solve Poissonâs equation with epsilon depending on z, expanding the potential in a Fourier-Bessel series, finding the image potential of the barriers. We calculate the electric current through this potential in function of the applied voltage, varying temperature and the distance between the barriers. We also consider gradual interfaces for the simple barrier case.
|
114 |
Avaliação das forças, momentos e binding, produzidos por deformação de primeira ordem do fio NiTi .014 superelástico, em braquetes autoligáveis passivos estudo in vitro / Evaluation of force, moment and binding produced by first order deformation on a superelastic .014 Niti wire using passive self-ligated brackets in vitro studyGilberto Vilanova Queiroz 09 April 2010 (has links)
Os efeitos mecânicos exercidos sobre os dentes pela deformação do fio de níqueltitânio dependem de sua rigidez e das características dos braquetes. Os fatores associados ao braquete são a largura, que influencia o comprimento de fio interbraquetes e o coeficiente de atrito. O objetivo desta pesquisa foi comparar a influência dos braquetes autoligáveis passivos Damon, Easy Clip e Smart Clip, sobre as forças, momentos e binding produzidos pela deformação do fio Contour NiTi .014. Metodologia: um dispositivo de simulação clínica com 3 braquetes .022x.028 de aço, correspondentes ao canino e pré-molares, foi acoplado à maquina de tração universal Instron para registro das forças e ao dinamômetro Lutron para registro dos momentos na unidade de ancoragem. A deformação de primeira ordem do fio superelástico Contour NiTi .014 foi propiciada pelo deslocamento do braquete do primeiro pré-molar fixo à máquina Instron. Foi utilizada célula de carga de 500 Newtons e velocidade de 0,05mm/segundo durante a deformação. As forças e momentos foram registrados até deslocamento máximo de 4,5 mm e durante retorno à zero. Foram realizadas dez repetições para cada modelo de braquete. O registro do binding foi obtido em teste separado por meio da tração contínua do fio Contour NiTi durante deformação de primeira ordem até 4,8 mm e retorno até zero. Os efeitos mecânicos foram comparados com deformação de 4 mm. Resultados: na unidade de movimentação as forças de ativação apresentaram diferenças significantes (Damon 224, Easy Clip 241 e Smart Clip 299 cN) enquanto as forças de desativação foram menores no Damon (62 Cn) e semelhantes entre os braquetes Easy Clip (71 cN) e Smart Clip (76 Cn). Na unidade de ancoragem os momentos de ativação apresentaram diferenças significantes (Damon 314, Easy Clip 356 e Smart Clip 438 cN/mm) enquanto os momentos de desativação foram semelhantes entre os braquetes Damon e Easy Clip (239/242 cN/mm) e significativamente maiores no Smart Clip (317 cN/mm). Os valores de binding na ativação e desativação foram semelhantes. O percentual de histerese das forças foi 70% e dos momentos 28%. Conclusões: 1) as forças de desativação produzidas pelo fio Contour NiTi .014 foram semelhantes, o que indicou equivalência mecânica entre os braquetes Damon, Easy Clip e Smart Clip na unidade de movimentação; 2) os momentos de desativação produzidos pelo fio Contour NiTi .014 foram semelhantes entre os braquetes Damon e Easy Clip, e maiores no Smart Clip, o que indicou equivalência mecânica apenas entre os braquetes Damon e Easy Clip na unidade de ancoragem ; 3) a medição das forças de atrito por meio da tração contínua do fio ortodôntico não se mostrou adequada para medir o binding associado à força de desativação; 4) a histerese acentuada observada no início da desativação das forças foi influenciada pela superelasticidade do fio e pelo binding na unidade de ancoragem. / Bracket characteristics and wire stiffness dictate the mechanical effects that nickel titanium wire deformation will cause upon teeth. The main variables associated to bracket characteristics include bracket length (that influence interbracket distance), and coefficient of friction. The purpose of this research was to compare how self ligated brackets such as Damon, Easy Clip and Smart Clip influence moments, forces, and binding produced by the deformation of a .014 Niti Contour wire. Methods: a clinical simulation device with three .022x.028 stainless steel brackets representing canine and bicuspids was attached to an Instron universal traction machine in order to register the forces, and to a Lutron dynamometer to register the moments produced on the anchor unit. The displacement of the first bicuspid fixed on the Instron machine produced a first order deformation on the superelastic .014 Niti Contour wire. A load cell of 500 Newtons under a speed of 0,05mm/second was used during the deformation. Forces and moments were registered up to 4,5mm maximum displacement and during the return to zero. For each bracket model ten repetitions were performed. Binding registration was obtained on a separate test, by continuous traction of the Contour Niti wire during first order deformation up to 4,8mm and back to zero. The mechanical effects were compared with a 4mm deformation. Results: on the moving unit, the activation forces presented significant differences (Damon 224, Easy Clip 241 and Smart Clip 299cN), while the deactivation forces were smaller on Damon (62cN) and similar on the Easy Clip (71cN) and Smart Clip (76 cN). The activation moments on the anchor unit presented significant differences (Damon 314, Easy Clip 356 and Smart Clip 438 cN/mm), while the deactivation moments were similar in the Damon (239 cN/mm) and Easy Clip (242 cN/mm) brackets, and significantly larger on Smart Clip (317cN/mm). Activation and deactivation binding values were similar. The hysteresis percentage on forces was 70% and on moments 28%. Conclusions: 1) the forces produced by the .014 Contour Niti at the movement unit are similar among the Damon, Easy Clip and Smart Clip brackets; 2) the moments produced by the .014 Contour Niti at the anchor unit are similar between Damon and Easy Clip brackets, while the Smart Clip produces larger moments; 3) the method of measuring friction forces by continuous traction of the orthodontic wire is not adequate to measure the binding associated with deactivation forces; 4) hysteresis observed at the beginning of deactivation is influenced by binding.
|
115 |
Avaliação da resistência ao deslocamento na sobreposição de fios de níquel e titânio superelásticos termoativados em braquetes autoligáveis passivos / Assessment of the displacement resistance of overlapped heat-activated superelastic nickel titanium wires in passive self-ligating bracketsMariana de Aguiar Bulhões Galvão 22 August 2014 (has links)
Objetivos: O objetivo desta pesquisa foi comparar a resistência ao deslocamento de fios de níquel e titânio superelásticos termoativados sobrepostos, em braquetes ortodônticos metálicos autoligáveis passivos. Material e Métodos: Foram utilizadas três espessuras de fios de níquel e titânio superelásticos termoativados (NiTi-TA): 0,014 sobreposto ao 0,016 e 0,020 (FlexyNiTi Thermal - Orthometric, Marília, SP, BR), associados a dois tipos de braquetes metálicos autoligáveis passivos: SmartClip SL3® (3M Unitek, Monrovia, CA, EUA) e OrthoClip SLB® (Orthometric, Marília, SP, BR). Um dispositivo que continha 5 braquetes de cada tipo (do incisivo central superior direito ao 2º pré-molar superior direito) foi desenvolvido para realização dos testes. O braquete do canino foi colado em uma barra de aço inoxidável móvel que permitia alterar sua posição vertical, enquanto os demais braquetes foram colados a uma barra fixa de acrílico. As forças obtidas por meio do deslocamento vertical do braquete do canino de 0mm para 1,5mm, 3,0 mm, 4,5mm e 6,0 mm foram registradas. O ambiente de teste foi seco com temperatura controlada de 36,5º C ± 1º C. Um total de 160 testes foi realizado na máquina de ensaios universal Instron. Os testes estatísticos de Shapiro-Wilk, teste t de Student não pareado e ANOVA com testes post-hoc de Tukey foram aplicados aos dados (p<0,05). Resultados: A distribuição normal da amostra foi confirmada, e os testes paramétricos demonstraram que houve diferenças estatisticamente significativas no braquete SmartClip SL3® quando associados aos fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 nas alturas de 1,5mm (p=0,003) e 6mm (p0,0001). Porém, não foram encontradas diferenças estatísticas nas alturas de 3mm (p=0,76) e 4,5mm (p=0,09). No braquete OrthoClip SLB® houve diferenças estatisticamente significativas entre os fios de NiTi-TA 0,020 e 0,014 sobreposto ao 0,016 em todas as alturas avaliadas (p0,0001). Na comparação entre os braquetes, quando associados ao fio 0,020 de NiTi-TA houve diferenças estatisticamente significativas na altura de 1,5mm; 3mm e 6mm (p0,0001). No entanto, na altura de 4,5mm as diferenças não foram significativas estatisticamente (p=0,32). Quando associados aos fios de NiTi-TA 0,014 e 0,016 sobrepostos, as diferenças em todas as alturas avaliadas foram significativas estatisticamente (1,5mm - p=0,0006; nas demais alturas p0,0001). Conclusão: Nos braquetes SmartClip SL3®, em desnivelamentos de 1,5mm, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento, enquanto que na altura de 6mm a menor resistência foi obtida com o fio de NiTi-TA 0,020. Nas demais alturas não houve diferenças estatísticas entre os fios. Para os braquetes OrthoClip SLB®, os fios de NiTi-TA 0,014 e 0,016 sobrepostos apresentaram menor resistência ao deslocamento em todas as alturas avaliadas. Na comparação entre os dois tipos de braquetes, associados ao fio de NiTi-TA 0,020 na altura de 1,5mm, o braquete OrthoClip SLB® apresentou menor resistência ao deslocamento, ao passo que nas alturas de 3mm e 6mm foi o braquete SmartClip SL3®. Na altura de 4,5mm não foram encontradas diferenças estatisticamente significativas entre os dois braquetes avaliados. / Objective: The objective of this research was to compare the displacement resistance of overlapped heat-activated superelastic nickel titanium wires, in passive self-ligating metallic brackets. Material and Methods: Three thicknesses of heat-activated superelastic nickel titanium wires (NiTi-TA) were used: 0.014 overlapped with 0.016 and 0.020 (FlexyNiTi Thermal - Orthometric, Marília, SP, BR), associated with two types of passive self-ligating metallic brackets: SmartClip SL3® (3M Unitek, Monrovia, CA, EUA) and OrthoClip SLB® (Orthometric, Marília, SP, BR). A device with 5 brackets of each type (from right central incisor to the second maxillary premolar) was developed for this research. The canine bracket was attached to a sliding stainless steel bar which allowed the alteration of its vertical position, while the remaining brackets were attached to a fixed acrylic bar. The forces generated by means of the canine bracket vertical displacement from 0mm to 1.5mm; 3.0mm; 4.5mm and 6.0mm were recorded. The test environment was dry with a controlled temperature of 36.5º C ± 1º C. A total of 160 tests were carried out in the Instron Testing Machine. The Shapiro-Wilk test, non-paired Student t-test and ANOVA with Tukey post hoc test were applied to the data (p<0.05). Results: The normal distribution was confirmed, and the parametric tests showed that there were statistically significant differences in the SmartClip SL3® when associated with the NiTi-TA 0.020 and 0.014 wires overlapped to the 0.016 wire in the height of 1.5mm (p=0.003) and 6mm (p<0.0001). However, statistically significant differences were not found in the heights of 3mm (p=0.76) and 4.5mm (p=0.09). For the OrthoClip SLB® brackets, there were statistically significant differences between the NiTi-TA 0.020 and 0.014 wires overlapped with the 0.016 wire in all the heights assessed (p<0.0001). In the comparison between the brackets when associated with the NiTi-TA 0.020 wire, there were statistically significant differences in the heights of 1.5mm, 3mm and 6mm (p<0.0001). However, in the height of 4.5mm the differences were not statistically significant (p=0.32). When associated with the overlapped NiTi-TA 0.014 and 0.016 wires, the differences in all assessed heights were statistically significant (1.5mm - p=0.0006; other height - p0.0001). Conclusion: For the SmartClip SL3® brackets, with 1.5mm of displacement, the overlapped NiTi-TA 0.014 and 0.016 wires showed less displacement resistance, while in the height of 6mm the least displacement resistance was found with the NiTi-TA 0.020. In the remaining heights, there were no statistically significant differences between the wires. For the OrthoClip SLB® brackets, the overlapped NiTi-TA 0.014 and 0.016 wires showed the least displacement resistance in all the assessed heights. In the comparison between the two types of brackets, associated with the NiTi-TA 0.020 wire, for the height of 1.5mm, the OrthoClip SLB® bracket showed less displacement resistance, while for the heights of 3mm and 6mm the SmartClip SL3® brackets showed less displacement resistance. For the height of 4.5mm there were no statistically significant differences found between the assessed brackets.
|
116 |
Avaliação do efeito de diferentes tipos de fios ortodônticos sobre a viabilidade celular e produção de óxido nítrico em células J774Toledo, Carlos Eduardo Pelinson 14 February 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-01T13:35:42Z
No. of bitstreams: 1
carloseduardopelinsontoledo.pdf: 607534 bytes, checksum: 4be22c339daceeb5a28d5226bd766121 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-02T12:58:11Z (GMT) No. of bitstreams: 1
carloseduardopelinsontoledo.pdf: 607534 bytes, checksum: 4be22c339daceeb5a28d5226bd766121 (MD5) / Made available in DSpace on 2016-07-02T12:58:12Z (GMT). No. of bitstreams: 1
carloseduardopelinsontoledo.pdf: 607534 bytes, checksum: 4be22c339daceeb5a28d5226bd766121 (MD5)
Previous issue date: 2012-02-14 / O ambiente bucal é particularmente favorável à biodegradação de metais devido às suas propriedades iônicas, térmicas, microbiológicas e enzimáticas. Estudos têm demonstrado que íons metálicos podem ser liberados de matérias metálicos como resultado da corrosão. Outros apontam que o Níquel é um componente comum em muitos materiais ortodônticos e uma alergia ao Níquel é comumente observada na população. Juntamente com os testes de citotoxicidade tradicionais, o estudo da produção celular de Óxido Nítrico (NO) estimulado por determinado material é um método capaz de avaliar seu potencial citotóxico. O presente estudo teve como objetivo avaliar pelo método MTT [3-(4,5-dimetil-2-tiazolil)-2,5-difenil tetrazólio brometo] a viabilidade celular de macrófagos murinos J774 na presença de 9 diferentes fios ortodônticos e o estímulo dos fios à produção de NO produzido por estas células. A avaliação das culturas celulares foi realizada em três intervalos de tempo: 24, 48 e 72 horas. A viabilidade celular em todos os grupos foi maior no intervalo de tempo final, que no intervalo de tempo inicial. Este aumento foi significativo no grupo controle. Nos grupos dos materiais, a média final da viabilidade celular no tempo de 72 horas não mostrou diferença significativa quando comparado com o grupo controle. A produção de NO em todos os grupos foi maior no intervalo de tempo final, que no intervalo de tempo inicial. Este aumento foi estatisticamente significativo no grupo controle. Nos grupos dos materiais, a média final da produção de NO apresentou diferença significativa apenas no grupo 8 (beta-Titânio), quando comparado com o grupo controle. Numa segunda etapa do estudo os macrófagos foram ativados com interferon-gama
(IFN-) procurando simular uma condição comum no organismo humano no qual estas citocinas são produzidas e liberadas frente à presença de antígenos. As médias da análise da viabilidade celular dos macrófagos murinos ativados com interferon-gama nos grupos dos fios ortodônticos não apresentaram diferença estatisticamente significativa quando comparada com a média das células do grupo controle. As médias da análise da produção de óxido nítrico pelos macrófagos murinos ativados com interferon-gama nos grupos dos fios ortodônticos não apresentaram diferença estatisticamente significativa quando comparada com a média das células do grupo controle. / The oral environment is particularly favorable to metal biodegradation due to is ionic, thermal, microbiological, and enzymatic properties. Studies have shown that metal ions may be released from metallic materials as the result of corrosion. Other studies demonstrate that Nickel is a common component in many orthodontic materials and that an allergy to Nickel is commonly observed in the population. In addition to the traditional cytotoxicity tests, the study of nitric oxide cellular production stimulated by a specific material has shown to be a reliable tool for evaluating its cytotoxic potential. The present study was aimed at assessing cellular viability by MTT [3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl tetrazolium bromide] assay in a murine macrophage cell line J774 in the presence of 9 different orthodontics wires and quantify nitric oxide production by these cells. Evaluation of cell culture was undertaken in three time intervals: 24, 48 and 72 hours. The cellular viability in all groups was higher at the final time interval than at the initial time interval. This increase was statistically significant in the control group. In the material groups, the final mean of cellular viability at 72 hours showed no statistically significant difference when compared with the control group. NO production in all groups was higher at the final time interval than at the initial time interval. This increase was statistically significant in the control group. In the material groups, the final mean of NO production at 72 hours was only significant in group 8 (beta-Titanium) when compared with the control group. In a second step of the study, macrophages were activated with gamma interferon (IFN-) in order to stimulate a common condition of the human body in which these cytokines are produced and released with the
presence of antigens. The means of the analysis of cell viability of murine macrophages activated with gamma interferon in the groups of orthodontic wires did not show statistically significant difference when compared to the mean of cells in the control group. The means of the analysis of NO production by the murine macrophages activated with gamma interferon in the groups of orthodontic wires did not show statistically significant difference when compared to the mean of cells in the control group.
|
117 |
Avaliação da quantidade de movimentação dentária com fios de níquel-titânio e aço multifilamentado na fase inicial de tratamento ortodôntico com aparelho fixo / Evaluation of the amount of tooth movement with nickel-titanium and multistrandred stainless steel wires in the initial phase of orthodontic treatment with fixed applianceQuintão, Ana Paula Abdo 12 July 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-05-15T12:12:28Z
No. of bitstreams: 1
anapaulaabdoquintao.pdf: 2338216 bytes, checksum: a3e802cebaa20531b4cc4d48d68342b6 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-17T15:53:31Z (GMT) No. of bitstreams: 1
anapaulaabdoquintao.pdf: 2338216 bytes, checksum: a3e802cebaa20531b4cc4d48d68342b6 (MD5) / Made available in DSpace on 2017-05-17T15:53:31Z (GMT). No. of bitstreams: 1
anapaulaabdoquintao.pdf: 2338216 bytes, checksum: a3e802cebaa20531b4cc4d48d68342b6 (MD5)
Previous issue date: 2017-07-12 / Este ensaio clínico retrospectivo randomizado longitudinal teve como objetivo comparar a eficácia clínica de duas ligas diferentes de fios ortodônticos (0,016 "de níquel-titânio e 0,0155" coaxial multifilamentado, utilizados para o alinhamento e nivelamento dos dentes durante 6 semanas. Avaliou-se também a quantidade de movimentação tridimensional. A tecnologia digital tem sido amplamente utilizada em modelos de gesso tridimensionais. Entretanto, há um pequeno número de ensaios clínicos. Métodos: A amostra foi composta por dois grupos de modelos de gesso obtidos de 12 pacientes jovens cada, incluindo ambos os maxilares, superior e inferior, dos pacientes. Os moldes foram digitalizados, com o escâner Maestro 3D, em dois tempos diferentes de tratamento: T1, antes da colocação do fio; e T2, 8 semanas após a sua colocação, totalizando 96 imagens digitalizadas. O programa Geometric Qualify foi utilizado para superposição de maxilares superiores e inferiores. Usando as rugas palatinas como ponto fixo para superposição das arcadas superiores, um método utilizando os modelos em oclusão foi criado pra transferir um ponto fixo das arcadas superiores para as arcadas inferiores, permitindo também, a superposição das mesmas. A quantidade precisa de movimento gerada por cada tipo de fio foi medida e visualizada através do programa CMF Application, usando linhas de contorno e mapas coloridos como ferramentas. Resultados: O fio 0,016" níquel-titânio promoveu maior quantidade de movimento dentário, que foi estatisticamente significativa, utilizando o teste de Mann-Whitney U (p <0,05). Conclusão: Os fios de níquel-titânio promoveram maior quantidade de movimentação dentária do que os fios de aço inoxidável multifilamentado. / This longitudinal retrospective randomized clinical trial aimed to compare the clinical effectiveness of two different orthodontic alloy wires (.016” nickel-titanium and .0155“ multistranded coaxial) used for dental alignment and leveling during 6 weeks. The amount of tridimensional movement was also evaluated. Digital technology has been widely used in three-dimensional dental casts. Therefore, there are a short number of clinical trials. Methods: The sample was composed by two groups of 12 young patients’ casts of both upper and lower jaws. The casts were digitalized, with Maestro 3D scanner, in two different times of treatment: T1 was before the wire was placed and T2 was 8 weeks after its placement, in a total of 96 jaw digitalized images. Geometric Qualify Software was used to generate the superimposition of upper and lower jaws. Using the palatal ruggaes as a fixed point for superimposition of the upper jaw, a method using it and the models in occlusion was created to transfer a fixed point to the lower jaws, allowing its superimposition as well. The precise quantity of movement generated by each type of wire was measured and visualized through CMF Application software by using isolines and color maps tools. Results: The .016" nickeltitanium wire promoted greater amount of tooth movement, which was statistically significant, using Mann-Whitney U test (p < 0.05). Conclusion: The nickel-titanium wires promoted a higher quantity of tooth movement than the multistranded stainless steel wire.
|
118 |
Posicionamento de m?ltiplos Sinks em redes de sensores sem fio com prioriza??oPeixoto, Jo?o Paulo Just 15 December 2015 (has links)
Submitted by Ricardo Cedraz Duque Moliterno (ricardo.moliterno@uefs.br) on 2016-04-07T00:24:20Z
No. of bitstreams: 1
Posicionamento de Multiplos Sinks em RSSF com Priorizacao.pdf: 1718384 bytes, checksum: e4372e2075ce58446664e4be89f2676f (MD5) / Made available in DSpace on 2016-04-07T00:24:20Z (GMT). No. of bitstreams: 1
Posicionamento de Multiplos Sinks em RSSF com Priorizacao.pdf: 1718384 bytes, checksum: e4372e2075ce58446664e4be89f2676f (MD5)
Previous issue date: 2015-12-15 / Wireless Sensor Networks can be used for environment monitoring, which may be in indoor scenarios such as in industries, warehouses and buildings, or in outdoor scenarios, just like forests, vulcanos and cities. Due to its energy supply limitations, researchers have been developing several approaches to reduce energy consumption
in sensors and extend their lifetime. One of the ways to improve energy usage in a Wireless Sensor Network is by using multiple mobile sinks. In this work, a method to position multiple sinks in a relevance-based Wireless Sensor Network is proposed. After several simulations, it was observed that in applications where
sensors have di erent importance levels, the network lifetime can be extended by using this approach. / Redes de Sensores Sem Fios podem ser utilizadas para o monitoramento de ambientes, sejam eles internos como ind ?strias, galp?es, constru??ess, ou externos como florestas, vulc?es, cidades, entre outros. Devido a sua limita ??o no fornecimento de energia, pesquisadores tem desenvolvido diversas abordagens para reduzir o consumo energ?tico nos sensores e prolongar seu tempo de vida. Uma das formas de melhorar o consumo de energia em uma Rede de Sensores Sem Fios e atrav?s do uso de m ?ltiplos sinks m oveis. Neste trabalho, e proposto um m ?todo para posicionamento de m ?ltiplos sinks em uma Rede de Sensores Sem Fios baseada em relev?ncias. Ap ?s diversas simula ??es, foi observado que em aplica ??es onde sensores possuem diferentes ni veis de import?ncia, o uso dessa abordagem aumenta o tempo de vida da rede.
|
119 |
[pt] CRESCIMENTO DE PONTOS QUÂNTICOS POR STRANSKI-KRASTANOV E POR CRESCIMENTO SELETIVO EM NANOFIOS VISANDO APLICAÇÃO EM DISPOSITIVOS OPTOELETRÔNICOS / [en] GROWTH OF QUANTUM DOTS BY STRANSKI-KRASTANOV MODE AND BY SELECTIVE AREA GROWTH IN NANOWIRE FOR OPTOELECTRONIC DEVICESRUDY MASSAMI SAKAMOTO KAWABATA 08 March 2016 (has links)
[pt] As premências da sociedade contemporânea têm dependido gradativamente mais do uso de dispositivos optoeletrônicos como solução para o aperfeiçoamento de inúmeras aplicações diárias. Notadamente na última década, áreas como a de geração de energia elétrica com células solares inorgânicas ou a de computação com o advento de computadores quânticos baseados em fótons únicos têm acumulado muitos investimentos em pesquisa. Este trabalho visa estudar e definir os parâmetros necessários para a produção de pontos quânticos (QD, do inglês Quantum Dot) de semicondutores III-V com o objetivo de aplicá-los como material ativo para células solares de banda intermediária (IBSC, do inglês Intermediate Band Solar Cell) e para emissores de fótons únicos quando inseridos em nanofios (QD-in-NW, do inglês QD in Nanowire). Para a aplicação em IBSC, os pontos quânticos são produzidos auto organizadamente pelo modo Stranski-Krastanow. A estrutura de banda do IBSC requer um poço de potencial fundo o suficiente para gerar 3 absorções em paralelo de fótons com energias distintas (um proveniente da energia de gap do material da barreira, um da absorção banda-banda do poço de potencial e o terceiro da absorção intra-banda do poço na banda de condução). Os materiais escolhidos foram barreiras de AlxGa1-xAs e poço de InAs crescidos sobre um substrato de GaAs(100). Os resultados do crescimento dessa estrutura foram analisados por microscopia de força atômica (AFM, do inglês atomic force microscopy), microscopia eletrônica de varredura (MEV), microscopia eletrônica de transmissão (MET) e fotoluminescência (PL, do inglês photoluminescence). Para a aplicação em emissores de fótons únicos, os QDs (de InxGa1-xAs) são crescidos axialmente sobre nanofios de GaAs em substrato de GaAs(111)B. A técnica de crescimento escolhida neste caso foi o crescimento seletivo (SAG, do inglês selective area growth) que traz muitas vantagens com relação à qualidade cristalina e futuras litografias para fabricação do dispositivo. Tal técnica consiste na aplicação de uma máscara sobre o substrato com buracos nanométricos dentro dos quais a epitaxia ocorre exclusivamente. Os resultados de crescimento da estrutura foram analisados por MEV, MET, PL e espectroscopia de raios X por dispersão em energia (EDX, do inglês Energy-dispersive X-ray Spectroscopy). Em ambos os casos, o crescimento das estruturas finais foi otimizado. Foi possível obter correlações da influência de cada parâmetro de crescimento na morfologia, cristalinidade e composição das estruturas. No caso dos QDs para IBSC, o método usado de recobrimento por In-flush foi determinante para a melhoria da qualidade cristalina das camadas e da homogeneização da altura dos QDs. No caso da estrutura de QD-in-NW, primeiro precisou-se encontrar os parâmetros de crescimento dos nanofios para atingir uma razão de aspecto alta, e só posteriormente estudou-se as condições para que o InAs crescesse axialmente sobre o nanofio. As caracterizações, principalmente a ótica, de ambos os trabalhos indicam que as estruturas propostas foram produzidas. / [en] In contemporary society the dependence on optoelectronic devices for countless daily applications has increased gradually. Particularly in the last decade fields such as energy generation through inorganic solar cells or quantum computation based in exchange of single photons has been heavily funded for their development. The aim of this thesis is defining the production parameters needed to fabricate quantum dots (QD) based on III-V semiconductors with planar geometry for intermediate band solar cell (IBSC) and with nanowire geometry (quantum dot in nanowire, QD-in-NW) for single photon emitter applications. For IBSC, the QDs are generated via self-assembly by Stranski-Krastanow mode. The IBSC s band structure requires a potential well deep enough to have 3 parallel photon absorption in different energy ranges (one is the barrier s energy gap, another is from the valence band to the intermediate band and the third one is from the intermediate band to the top of the barrier). The selected materials were AlxGa1-xAs as barriers, InAs as well, all grown on GaAs(100) substrate. The growth results were analysed by atomic force microscopy (AFM), scanning eléctron microscopy (SEM), transmission eléctron microscopy (TEM) and photoluminescence (PL). For the single photon emitters, the QDs (InxGa1-xAs) are grown axially over GaAs nanowires on a GaAs(111)B substrate. The chosen growth technique was the selective area growth (SAG) that brings many advantages in crystal quality and device lithography. This technique consists of applying a mask over the substrate with nanometric holes inside which the epitaxy occurs. The results were analysed by SEM, TEM, PL and energy dispersive X-ray spectroscopy (EDX). In both cases, the growth of the structures were optimized for better quality. The growth parameters could be correlated with the structure’s morfology, cristalinity and composition. For the IBSC, a capping method named In-flush was used to increase the crystal quality from the layers and the homogeneity from the QD s heights. For the QD-in-NW, firstly the nanowire s growth was optimized for higher aspect ratio and only then the growth of the InAs QD was optimized for axial growth over the nanowire. In both cases the optical measurements show that the proposed structures were grown successfully.
|
120 |
Desenvolvimento de procedimento utilizando processo de soldagem plasma para confecção de sementes de Iodo125 / Development of a procedure using plasma welding process to produce 125I seedsFeher, Anselmo 13 December 2006 (has links)
O câncer de próstata é um problema de saúde pública no Brasil, sendo a segunda causa de óbitos por câncer em homens, superado apenas pelo câncer de pulmão. Entre os possíveis tratamentos disponíveis para o câncer de próstata encontra-se a braquiterapia, onde, pequenas sementes contendo o radioisótopo 125I são implantadas na próstata. A semente consiste de uma cápsula de titânio selada de 0,8 mm de diâmetro externo e 4,5 mm de comprimento, contendo um fio de prata com 125I adsorvido. A soldagem por arco plasma é uma das técnicas viáveis para selagem, o equipamento tem um custo menor que o de outros processos. Constituem os objetivos deste trabalho o desenvolvimento e a validação do procedimento de selagem utilizando processo de soldagem plasma e a elaboração de rotinas para selagem segundo as Boas Práticas de Fabricação. O desenvolvimento do trabalho apresentou as seguintes fases: corte e limpeza do material, determinação dos parâmetros de soldagem, desenvolvimento de dispositivos para fixação do tubo de titânio durante o processo de soldagem, ensaios de validação de fontes seladas conforme norma ISO 2919 Sealed Radioactive Sources General Requirements and Classification, ensaios de estanqueidade conforme norma ISO 9978 Sealed Radioactive Sources Leakage Test Methods e ensaio metalográfico. O procedimento desenvolvido para a selagem das sementes de 125I mostrou-se eficiente, atendendo a todos os requisitos estabelecidos na norma ISO 2919. Os resultados apresentados neste trabalho possibilitaram a elaboração de rotinas de fabricação segundo as orientações apresentadas na resolução RDC nº 59 Boas Práticas de Fabricação de Produtos Médicos da ANVISA - Agência Nacional de Vigilância Sanitária. / The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer, is a problem of public health in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing 125I radioisotope are implanted in the prostate. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed 125I. The plasma arc welding is one of the viable techniques for the sealing process. The equipment used in this technique is less costly than in other processes. The main objective of this work was the development and the validation of the welding procedure using plasma welding process and the elaboration of a sealing routine according to Good Manufacturing Practices. The development of this work has presented the following phases: cut and cleaning of the titanium material, determination of the welding parameters, development of a device for holding the titanium tube during the welding process, validation of sealed sources according to ISO 2919 Sealed Radioactive Sources - General Requirements and Classification, leakage test according to ISO 9978 Sealed Radioactive Sources - Leakage Test Methods and metallographics assays. The developed procedure, to seal 125I seeds using plasma welding process, has shown to be efficient, satisfying all the established requirements of ISO 2919. The results obtained in this work have given the possibility to establish a routine production process according to the orientations presented in resolution RDC nº 59 - Good Manufacturing Practices to Medical Products of the ANVISA - National Agency of Sanitary Surveillance.
|
Page generated in 0.0843 seconds