• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 216
  • 42
  • Tagged with
  • 258
  • 139
  • 114
  • 113
  • 111
  • 72
  • 53
  • 53
  • 45
  • 37
  • 36
  • 29
  • 28
  • 27
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Samkörning mellan värmepumpar och fjärrvärme : Bostadsrättsföreningen Bogården

Sadik, Zidar January 2008 (has links)
This diploma work covers an investigation over the heat - and hot water systems of the tenant-owner's association, Bogården. The heat - and hot water needs of Bogården are satisfied by both district heating as well as three heat pumps. Implemented investigation shows that the heat pumps are not used in a profitable way. Apart from that, the reserve possibilities are small. There is also a risk of the growth of Legionella bacterium in the hot water system. Since the heat pumps are already installed, HSB-Gävleborg (responsible for Bogården) has a wish to investigate possible proposed actions for optimization of existing plant. After completed investigation, a new proposed action is presented. The new proposed action goes on intercepting the hot water production and using the heat pumps to only heat production during the heating season. Why the hot water production should be intercepted, is just in order to eliminate the risk of Legionella. Besides, the new proposal is going to bring about a reserve of 1,534,000 SEK during a twenty-year period. This is approximately twice as much as what the existing plant may bring during the same period. During the work's review, it also has been established that heat - and hot water systems are error regulated. Since the diploma work does not cover that piece it is instead informed as proposals subject to further investigation.
82

Uppvärmning och miljöpåverkan : -en jämförelse mellan fjärrvärme och bergvärme i villa

Ahlgren, Josef, Andersson, Stefan, Klintenheim, Johannes January 2008 (has links)
<p>Many of todays studies show that district heating is one of the betteralternatives as heating source because of its low environmental load.</p><p>The energy source is often leftovers from other processes producing energy or waste, like garbage or chips.</p><p>Electricity in combination with geothermal heating is another heating system that has increased sharply during the last years, and also this system decreases the discharges that have negative affects</p><p>on the environment compared to several other heating methods.</p><p>This report aims to, concentrated towards these two different heating systems, estimate the amounts of discharges they indirect cause and how the environment is affected.</p><p>We have calculated the mean value for discharges of carbon dioxide, nitrogen oxide, sulphur oxide and dust generated from electrical power used in Sweden.</p><p>Through interviews and research we have gained data for the same substances that district heating based on combustion of garbage and biofuel generates.</p><p>We have also in cooperation with a housing company chosen a building we see representative for many of the new single-family houses built in Sweden today.</p><p>Based on its shape and appearance we theoretically created three alternatives of the same house, each of them with climate screens different from each other.</p><p>Together with the amounts of discharged environmental affecting substances, these houses were the base for our calculations and studies when investigating the different heating sources environmental effect.</p><p>The results have thereafter been analyzed and discussed from different angles.</p>
83

Utredning och effektivisering av Gruvöns sekundärvärmesystem på barrsulfatlinjen : En studie med målet att möjliggöra en ökad fjärrvärmeleverans / Investigation and efficiency of Gruvöns secondary heating system at the softwood line : A study with the goal to enable an increased delivery of district heating

Skoglund, Daniel January 1900 (has links)
Fjärrvärme är idag den vanligaste formen av fastighetsuppvärmning i Sverige. Förutom värmeanläggningar som byggts just för ändamålet att leverera fjärrvärme har pappers- och massaindustrin blivit en betydande aktör på marknaden i de orter där industrin finns. BillerudKorsnäs massa- och pappersbruk på Gruvön i Grums kommun levererar fjärrvärme till kommunen och till det intilliggande sågverket.   Syftet med projektet är att genom kartläggning av Gruvöns sekundärvärmesystem på barrsulfatlinjen belysa effektiviseringsmöjligheter med en ökad fjärrvärmeleverans som följd.   Målet är att upprätta en simuleringsmodell i programmet Wingems och med hjälp av den se vad dessa effektiviseringsmöjligheter kan leda till i form av ökad fjärrvärmeleverans.   Metoden i arbetet har utgått från att kartlägga energiflöden till två vattencisterner på barrsulfatlinjens sekundärvärmesystem. Driftdata för vattenflöden i sekundärvärmesystemet har inhämtats i form av flödesstorlek och temperatur, vilka har legat till grund för en simuleringsmodell i Wingems.   Sekundärvärmesystemet på barrsulfatlinjen består av en ljumvatten-cistern, en hetvatten-cistern och ett antal värmeväxlare och kondensorer. Ett av de identifierade problemenen med systemet är att temperaturen i ljumvatten-cistern är högre än den borde. Anledningen till detta är ett vattenflöde från en värmeväxlare som kyler svartlut och leds in till cisternen. Vattenflödet håller en temperatur mellan 70-75°C. Huvudkonsumenten till cisternen är en förindunstare som förses med kylvatten. Temperaturen på vattnet bör ligga på 23°C. Vid en lägre temperatur skickas hetvatten från lövsulfatlinjen att värma vattnet till 23°C, på vägen passerar hetvattnet två värmeväxlare som överför energi till fjärrvärmenätet. Med en högre temperatur i cisternen krävs ett mindre flöde att förvärma kylvattnet, vilket leder till en minskad effekt ut på fjärrvärmenätet.   Resultatet visar att genom omledning av kylvattenflödet från svartlutkylaren till hetvatten-cistern på barrsulfatlinjen kan effektöverföringen till fjärrvärmenätet öka med 3,1 MW. En alternativ lösning skulle kunna vara att kyla svartluten med 74°C vatten från hetvatten-cisternen på barrsulfatlinjen. Kylvattnet kan sedan ledas in tillbaka till hetvatten-cisternen, svartlutkylaren skulle då bli en betydande energiproducent till systemet. Simuleringar visar att denna åtgärd skulle kunna ge en potentiell ökad effektöverföring till fjärrvärmenätet med 9 MW. / District heating is the most common form of house heating in Sweden today. Apart from heating plants that has been built to the purpose, the paper and pulp industry has become a significant contributor. BillerudKorsnäs paper and pulp mill at Gruvön in Grums municipality delivers district heating both to the residents in Grums and the nearby sawmill.   However it has been observed that the amount of energy transferred to the district heating network has been reduced after several redevelopments and new installations at the mill. The purpose with this report is through mapping of the mills secondary heating system find efficiency opportunities that will lead to an increased delivery of district heating. The goal is to develop a simulation model with the software Wingems and with the model make simulations to see the amount of increased district heating the efficiency opportunities may lead to.   To achieve this, the method has been to map the energy flow to and from two water tanks in the secondary heating system in the mills softwood line. Input data for streams in the secondary heating system has been gathered, and these have then been used to construct the simulation model.   The part of the secondary heating system that is located at the mills softwood line consists of one lukewarm water tank, one tank that contains hot water and several heat exchangers and condensers. One of the identified problems with the system is that the temperature in the lukewarm water tank is higher than it should be. The main consumer of the water tank is a pre-evaporator that is using water at the temperature of 23°C to condense some of the flash steam it produces. If the temperature of the water in the tank is below 23°C, hot water from the hardwood line is being pumped to heat the water to the pre-evaporator. The hot water passes two heat exchangers that transfer some of the energy to the district heating system. A higher temperature of the water in the lukewarm tank leads therefore to a smaller flow through the heat exchangers that in turn leads to a lower delivery of district heating.   The reason to the higher temperature in the lukewarm tank is a heat exchanger that cools black liquor from the pre-evaporator. The heated water used to cool the black liquor has a temperature between 70°C to 75°C. This water is being led to the lukewarm tank and is the main reason that the temperature in the tank is higher than designed. The results show that a rerouting of the heat exchangers cooling water to the tank containing hot water could lead to a 3,1 MW increased power transfer to the district heating network. Redesigning the heat exchanger to use water from the hot water tank to cool the black liquor and then lead the even hotter water back to the tank could lead to a 9 MW increased power transfer.
84

Utvecklingsmöjligheter för fjärrvärmens affärsmodell : Genom användning av byggnader som värmelager / Development opportunities for the district heating business model : Through the use of buildings as heat storage

Sirén, Tim January 2014 (has links)
Ett vanligt problem för fjärrvärmeföretag är svängningar i den dagliga efterfrågan på fjärrvärme. När efterfrågetoppar sker i fjärrvärmenätet behöver fjärrvärmeföretagen oftast använda sina topplastpannor, vilka vanligtvis drivs på både dyra och miljöovänliga bränslen. Ett sätt att åtgärda detta problem har traditionellt varit att använda en ackumulatortank som värmelager. Men med ny och billigare mät- och styrsystemteknik har kommersiella lösningar börjat växa fram där istället byggnader kan användas som värmelager. Syftet med examensarbetet är att undersöka de tekniska och ekonomiska möjligheterna för att använda byggnader som värmelager i ett fjärrvärmesystem och jämföra det med att använda en ackumulatortank som värmelager. Det förs en diskussion om hur ett samarbete skulle kunna se ut mellan fjärrvärmeföretag och fastighetsägare för att möjliggöra användningen av byggnader som värmelager. I examensarbetet genomförs en litteraturstudie och intervjuer för att både beskriva hur byggnader kan användas som värmelager och att beskriva intressenterna och deras relation. Det utförs även en fallstudie på Hudiksvalls fjärrvärmenät. I fallstudien används produktionsdata från Hudiksvalls fjärrvärmeproduktion och en analys utförs med hjälp av MATLAB och Microsoft Excel. I analysen besvaras frågan om hur stora kostnadsbesparingar och intäktsökningar som skulle kunna uppnås ifall Hudiksvalls fjärrvärmenät fick tillgång till värmelager i olika storlekar. Utifrån dessa kostnadsbesparingar och intäktsökningar görs en investeringsanalys. I investeringsanalysen jämförs de två alternativen för värmelager, det vill säga att använda byggnader som värmelager eller en ackumulatortank som värmelager. Utifrån de teoretiska studierna och fallstudien på Hudiksvalls fjärrvärmenät kan följande slutsatser dras: En investering i att använda byggnader som värmelager har en högre avkastning per investerad krona och kortare återbetalningstid än en investering i att använda en ackumulatortank. Skillnaderna är som störst vid små värmelager och minskar vid större storlek på värmelager. Detta beror på att den initiala investeringskostnaden för att använda byggnader som värmelager är lägre än den initiala investeringskostnaden för att använda en ackumulatortank som värmelager. En investering i att använda byggnader som värmelager har ett högre nettonuvärde vid små värmelagerstorlekar än en investering i att använda en ackumulatortank som värmelager. Men vid större storlekar på värmelagret ger en investeringen i en ackumulatortank ett högre nettonuvärde. Byggnader kan användas som värmelager utan att varken inomhuskomforten försämras nämnvärt eller att energiförbrukningen höjs beaktansvärt. Energiförbrukningen kan till och med sänkas ifall ett nytt värmestyrsystem installeras i en byggnad som ersätter ett äldre mindre effektivt värme-styrsystem. Både pengar och tid kan sparas ifall det redan finns en god relation mellan fjärrvärmeföretag och fastighetsägare, när byggnader ska användas som värmelager. Det mest fördelaktiga valet mellan att investera i byggnader som värmelager eller en ackumulatortank som värmelager skiftar alltså från fall till fall och inget av alternativen är alltid det bästa. För att ta ställning till vilken teknik som ska användas som värmelager behöver en analys göras för varje enskild situation. / A common problem for district heating companies is fluctuations in the daily demand for district heating. When peak demand occurs in the district heating network the district heating companies usually needs to use their peak load boilers, which are operated on both expensive and not sustainable fuels. One way to overcome this problem has traditionally been to use a storage tank as heat storage. But with new and cheaper measurements and control system technology has commercial solutions begun to emerge in which buildings can be used instead as heat storage. The aim of the thesis is to investigate the technical and economic feasibility of buildings as heat storage in a district heating system and compares it with the use of a storage tank as heat storage. There has also been a discussion of how collaboration might look like between the district heating company and the property owners to permit the use of buildings as heat storage. A literature review and interviews are conducted in the thesis in order to both describe how buildings can be used as heat storage and describe the stakeholders and their relationship. A case study is also carried out at Hudiksvall’s district heating network. The case study use production data from Hudiksvall’s district heating production and an analysis is carried out using MATLAB and Microsoft Excel. The analysis answers the question of how large cost savings and revenue increases that could be achieved if the district heating network had access to heat storage on various scales. Based on the cost savings and revenue increases, an investment analysis is carried out. In the investment analysis the two options, buildings as heat storage and storage tank as heat storage, are compared. Based on the theoretical studies and the case study at Hudiksvall’s district heating network it can be concluded that: An investment to use buildings as heat storage has a higher return per dollar invested and a shorter payback time than an investment to use a storage tank as a heat store. The differences are greatest for small size heat storages and approaching each other for large size heat storages. This is due to the lower initial investment cost when using buildings as heat storage compared to when using storage tanks as heat storage. An investment to use buildings as heat storage has a higher net present value for small heat storages compared to an investment to use a storage tank as heat storage. But for larger heat storage sizes an investment in storage tanks has a higher net present value. Buildings can be used as heat storage without a significant decrease in indoor comfort or a noteworthy increase in energy consumption. The energy consumption can even be reduced if a new heating control system is installed in a building to replace an older less efficient heat control system. Both money and time can be saved if there is already a good relationship between the district heating companies and the property owners, when the buildings should be used as heat storage. The best option for choosing between using buildings or a storage tank as heat storage depends on the situation and none of the options are always best. In order to decide which technology should be used as heat storage an analysis is required for each individual case.
85

Utveckling av lastmodell för Uppsala fjärrvärmenät / Development of a load prognosis model for Uppsala district heating system

Buddee, Ingrid January 2014 (has links)
The aim of this study was to develop a load prognosis model for Uppsala district heating system to be used as a tool for heat production optimization. The methodwas to build three models for the different customer types; housing, industry andoffices and then scale them for the total system using data from Uppsala districtheating system. The heat load consists of two parts, one that is temperaturedependent and one that is dependent of the social behavior of the customers. Thetemperature part was modelled with an ARX model using an outdoor temperatureprognosis as input signal. The social behavior part was modelled using the mean ofthe social behavior from some days before and additionally by distinguishing betweenweekdays and weekends. The outcome was a model that would produce a prognosisfor the heat load for each customer type. The total model for the whole districtheating system was less accurate, but still usable. All models developed are howeverrelying on the quality of the available weather prognosis. The benefit of a precise loadprognosis is to facilitate production planning and optimization. Accurate predictions ofthe heat demand, especially in the case of peak load, will result in better productionplanning and thus cost efficiency.
86

Installation av energikombinat vid Lillesjöverket : Tekniskt beslutsunderlag åt Uddevalla Energi för val av flistork

Sanftleben, Willy January 2014 (has links)
Med ett energikombinat vid Lillesjöverket vill Uddevalla Energi energieffektivisera samt sänka temperatur på återkommande fjärrvärmevatten, för att kunna utnyttja rökgaskondensorn effektivare. Uppdraget var att utreda mängden tillgänglig energi under sommarhalvåret och utföra en matematisk kalkyl som ska ligga till grund för val av tork. Valet stod mellan två alternativ av tork där storlek på värmeväxlararea och investeringskostnad skilde dem åt. Sedan följde dimensionering av fjärrvärmeledning samt cirkulationspump från fjärrvärmenätet till tork. Syftet var att ge Uddevalla Energi ett tekniskt beslutsunderlag för val av storlek på tork samt dimensionering av energiöverföring till densamma. Som metod användes flera olika beräkningsmodeller vid kalkylering av resultaten. Vid jämförelse mellan de två torkalternativen visade det sig att med en ökad investeringskostnad med 2,18 %, för en större värmeväxlararea i tork, ökade mängden energi som fanns tillgänglig till tork under sommarhalvåret med 16,7 %. Detta medförde att kostnaderna för tillskjuten energi sänktes med 65,9 % för att Uddevalla Energi skulle nå sitt mål på 60 GWh. För att nå målet krävdes enligt kalkyl en installation av torkalternativ 2 samt en sänkning av antalet dagar då verket står still på grund av underhåll. / With an energy combine at Lillesjöverket, Uddevalla Energi wants to improve energy efficiency and lower the temperature of the returning district heating water in order to utilize the flue gas condenser more effectively. The assignment was to investigate the availability of power during the summer months and perform a mathematical calculation that will form the basis for the selection of dryer. The selection stood between two options of dryer where the size of the heat exchanger area and investment costs separated them. Also performed were sizing of the district heating water pipeline and the circulation pump from the district heating water network to the dryer. The purpose was to present Uddevalla Energi with a technical basis for selection of the size of the dryer and sizing of energy transfer to the dryer. As method several different calculations were used when calculating the results. When comparing the two options, it turned out that with an increased investment cost of 2.18%, for a larger heat exchange area in the dryer, the amount of energy available to the dryer during the summer months increased by 16.7%. This meant that the cost for energy contributed, for Uddevalla Energi to achieve their goal of 60 GWh, is reduced by 65.9%. To achieve their goal it was required by calculations to install dryer option number two and a reduction in the number of days in which the work is at a standstill due to maintenance.
87

Fjärrvärmens konkurrenssituation : En studie av fjärrvärmens konkurrenskraft i Västerås

Bergman, Niklas, Wahlberg, Simon January 2018 (has links)
District heat is currently more exposed for competition than it has been for several years. Since the mid-1980s, district heat has dominated the heat market, but is now in a tougher competitive situation due to the increasing popularity of heat pumps. This, in combination with energy efficiency, has led to a stagnation of delivered energy. The purpose of the study is to investigate the district heating's current competitive situation in Västerås. This will be investigated based on pricing, performance and paragraphs. In order to get a comprehensive picture of the heat market and to find out what factors customers prioritize, housing companies, house makers and villa owners were interviewed. The study's results show that house owners prioritize delivery reliability, followed by economy and environment in the choice of heating method. Actors' views on pricing were different depending on the preferred heating method, where the different views were primarily about the operating and maintenance costs of heat pumps. In order to analyze pricing the life cycle cost was calculated on the basis of real cases. This was done by creating a calculation model in Excel. The result of pricing shows that district heating was the best option for all cases. However, from a new construction perspective, geothermal heat pump for small houses had similar life cycle cost as district heating, while district heating was superior in price for the larger houses. All cases when a customer had change from district heat to heat pumps were unprofitable due to the switching cost that arises. Performance was evaluated by the environmental impact and delivery reliability of the methods. The consequential life cycle assessment was used when calculating environmental impact. The result showed that the district heating in Västerås has a positive environmental impact because of the social benefits it provides. Heat pumps had a negative impact on the environment in all cases. The delivery reliability was studied through actors' views in combination with scientific research, which resulted in the view that district heating is better. The evaluation of paragraph was limited to Boverket’s building regulations. The competitive situation is currently skewed, where heat pumps have a big advantage as houses can limit their energy efficiency with heat pumps. The future of district heating in Västerås is bright. The challenge is to keep their market domination by maintaining a competitive price as the heat market is facing changes with reduced heat demand and tougher competition. / Fjärrvärmen är idag mer konkurrensutsatt än den har varit på flera år. Sedan mitten av 1980-talet har fjärrvärmen dominerat värmemarknaden, men är nu i en tuffare konkurrenssituation bland annat på grund av den ökande populariteten av värmepumpar. Dessutom har energieffektivisering och tuffare krav lett till en stagnation av levererad värme. Syftet med studien är att undersöka fjärrvärmens nuvarande konkurrenssituation i Västerås. Detta ska undersökas utifrån de tre konkurrensmedlen prissättning, prestanda och paragrafer. För att få en heltäckande bild av värmemarknaden samt att ta reda på vilka faktorer kunder prioriterar i valet av uppvärmningsmetod intervjuades bostadsföretag, hustillverkare och småhusägare. Studiens resultat visar att fastighetsägare prioriterar leveranssäkerhet, följt av ekonomi och miljö i valet av uppvärmningsmetod. Trots att samtliga lyfter fram ekonomi som den avgörande faktorn i valet, berodde det på att leveranssäkerheten antogs vara relativt lika mellan uppvärmningsmetoderna. Miljön har ett visst inflytande, dock så länge det inte innebär en allt för hög ekonomisk kostnad. Aktörers syn på prissättning var olika beroende på föredragen uppvärmningsmetod, där de skilda åsikterna främst gällde värmepumpars drift- och underhållskostnader. För att behandla prissättning opartiskt beräknades livscykelkostnaden för de valda uppvärmningsmetoderna utifrån verkliga fall. Detta gjordes genom att skapa ett beräkningsverktyg i kalkylprogrammet Excel där indata kan varieras. Resultatet av den ekonomiska kartläggningen visar att för samtliga fall var fjärrvärmen billigast. Ur ett nyproduktionsperspektiv hade dock bergvärmepump för småhus i princip samma livscykelkostnad som fjärrvärme, medan för de större fastigheterna var fjärrvärmen relativt överlägsen gällande pris. Samtliga konverterande fall där fastighetsägare bytt uppvärmningsmetod var olönsamma, detta på grund av den konverteringskostnad som uppstår. Konkurrensmedlet prestanda undersöktes genom metodernas miljöpåverkan och leveranssäkerhet. Vid beräkning av miljöpåverkan användes konsekvensperspektivet. Resultatet visade att fjärrvärmen i Västerås har en positiv miljöpåverkan på grund av samhällsnyttan den ger, medan värmepumpar i samtliga fall hade en negativ påverkan. För undersökningen av leveranssäkerhet involverades de två aspekterna driftsäkerhet och enkelhet. Detta gjordes genom att studera aktörers syn i kombination med tidigare forskning, vilket resultera i att fjärrvärme är bättre. Undersökning av paragrafer avgränsades till Boverkets byggregler som sätter kraven för fastigheters energiprestanda. I nuläget är konkurrenssituationen skev, där värmepumpar har en stor fördel då fastigheter kan byggas med sämre energiprestanda med värmepumpar. Fjärrvärmens framtid i Västerås är ljus. Utmaningen är att bibehålla deras stora marknadsandelar genom att upprätthålla ett konkurrenskraftigt pris då värmemarknaden står inför förändringar med minskat värmebehov och tuffare konkurrens.
88

Energioptimering av SSAB:s kraftverk i Oxelösund : Pinchanalys på det befintliga ångsystemet / Energy optimization of SSABs Power plant in Oxelösund : Pinch analysis of the integrated steam system

Fayazi, Javad January 2018 (has links)
In Oxelösunds there is a complete production facility, from metallurgy with the production of steel to rolling, formatting and hardening of sheet metal. SSAB Oxelösunds is producing world-famous trademarks such as Hardox, which is considered one of the world’s most advanced steel. SSAB has a goal to improve its energy efficiency by taking advantage of excess heat to reduce the demand of purchased energy, both in terms of fuel and electricity. Today SSAB Oxelösunds uses excess heat (blast furnace gas, coke gas and hot water) internally and also as additional fuel in the company’s power plant for electricity generation and district heating. The district heating and electricity are used internally and are also sent to Oxelösunds district heating network and the grid. One way to achieve SSAB’s energy efficiency goals is to perform an energy optimization of the factory’s existing power plant. The purpose of the thesis at SSAB’s power plant is to identify opportunities and for recovering excess heat from the existing steam system using Pinch analysis. This is done to increase electricity generation in the factory’s power plant. The aim is to produce flowchart for the existing plant based on an energy survey done on the power plant. The goal is also, by implementation of Pinch analysis over the existing heat exchanger network, to present changes to reduce energy consumption in the power plants that lead to increased power generation and how these changes can be made in practice. The thesis has been done at SSAB and the necessary data for the analysis has been developed using the IP21 database, which consists of logged data and as well as measured data with two different thermometers. Based on the generated data, a pinch analysis has been performed to investigate how heat exchange occurs in the plant which reveals how optimized the exchange of heat is. The pinch analysis has shown pinch violations consisting of heat exchange of streams over the pinch with streams under the pinch and vice versa by 1.5 MW. Possible measures to optimize and eliminate pinch violations have been investigated in the OK2 heat exchanger. OK2 consist of two boilers, 1 and 2, which is used for production of process steam and district heating. By using the high-grade 5 bar steam which is used in the current OK2 for district heating production to do a mechanical work in the high-pressure steam turbine in OK3 and then the condensed steam from the turbine can be reused for district heating production. OK3 consists of high and low-pressure steam turbine and district heat condenser. The suggested improvement means that the entire district heating production should be done by the condenses steam from turbine, both in the district heat condenser in OK3 and the heat exchanger in OK2.  The improvement suggestion lead to a decrease in entropy generation and an increase in exergy recovery, which means increased electricity production of 2.8 MW compared with the current operation. Assuming that district heating costs 0.22 kr/MWh and electricity costs 1 kr/MWh, the upgraded OK3.2 gives an extra income of 33 kr/MWh per fed fuel. The implementation of the improvement suggestion is expected to increase the overall energy efficiency of the plant, resulting in economic benefits. Based on discussions with operating technicians in the power plant, a possible change does not require major investment either.
89

Inkopplingsalternativ för frånluftsvärmepumpar : Analys av flerbostadshus i Kungälv

Svanqvist, Christian January 2018 (has links)
Sverige har målsättningen att sänka energianvändningen med 20 % till 2020 och för att lyckas med det behöver bland annat bostadssektorn dra sitt strå till stacken. Sedan miljonprojektet finns det ett stort antal flerfamiljshus med hög energikonsumtion och ett sätt att minska den är att installera frånluftsvärmepump. I det för projektet aktuella fallet ägs huset av kommunen som också äger fjärrvärmenätet som huset är anslutet till. Vid installation av frånluftsvärmepumpar i kombination med fjärrvärme kan problem med förhöjd returtemperatur till fjärrvärmenätet uppstå. Projektets mål har varit att identifiera besparingspotentialen hos olika installationsalternativ och att se hur de påverkar returtemperaturen till fjärrvärmenätet. Med simuleringar har fastslagits att den största besparingspotentialen finns när frånluftsvärmepumpen får arbeta mot uppvärmning av radiatorvattnet samt momentan uppvärmning av tappvattnet. Denna inkoppling leder också till god avkylning. Bäst avkylning leder dock en liknande inkoppling men med värmelager för tappvattnet. Känslighetsanalysen gör gällande att en höjning av elpriset ger en viss försämring av besparingen och en höjd framledningstemperatur från frånluftsvärmepumpen gör också att besparingen minskar. En sänkning av framledningstemperaturen för radiatorkretsen leder till en ganska stor ökning av besparingen.
90

Värme i ledning. : En kvalitativ studie om fjärrvärmens framväxt i Umeå,Karlstad och Mjölby 1940–1980.

Stefansson, Eric January 2017 (has links)
Denna uppsats undersöker motiven bakom byggandet av fjärrvärmesystem i Tre svenska städer. Sopförbränningsanläggningen Ålidhemsverket i Umeå, samt det fjärrvärmesystem som är kopplat till anläggningen, och fjärrvärmesystemen i Karlstad och Mjölby. I fallet Ålidhemsanläggningen var Umeås växande befolkning, med ökad befolkningstäthet som följd en viktig faktor. Politikerna menade att luftföroreningarna till följd av eldning för bostadsvärme riskerade bli omfattande. Även sophanteringen väntades bli problematisk i takt med att staden blev större. När stadsdelen Ålidhem skulle byggas under 1960-talet uppstod ett läge där värme från sopdestruktion kunde användas. Miljonprogramssatsningen var en av de stora anledningarna till att fjärrvärmesystem byggdes i många svenska städer. De tre städerna byggde sina respektive system i olika tider varför det är intressant att jämföra dessa tre fall. Karlstads fjärrvärmesystem var det första i Sverige och stod klart under sent 1940-tal, Umeå byggde sitt under sent 1960-tal medan byggandet i Mjölby skedde under 1980-talet. I Karlstads fall var det behovet av extrakraft som ledde till byggande av kraftvärmeverk, och sedan fjärrvärmesystem. I Umeå var miljöaspekterna centrala. I Mjölby bestod drivkrafterna i stor utsträckning av statligt förd energipolitik i tiden efter oljekriserna, då politikerna hade för avsikt att minska landets beroende av fossila bränslen.

Page generated in 0.0393 seconds