241 |
Effect of microfibrillar cellulose on concrete equivalent mortar fresh and hardened properties / Inverkan av mikrofibrillär cellulosa på egenskaperna hos betongekvivelent bruk i dess färska och hårdnade tillståndNilsson, Jonas, Sargenius, Peter January 2011 (has links)
A pilot project in 2010, conducted at CBI, showed the capacity for pulp, micro fibrilars from the forest industry to act as Viscosity Modifying Agent (VMA) in concrete. This project was, however, too limited to find answers for optimal use of this kind of material. The forest industry company Stora Enso wants to find out if their pulp can be used in concrete in order to somehow improve its properties. Two micro fibrilar suspensions have been tested. The tested fibrils are in two sizes, the finer material named MFC1 has undergone more homogenization than the course material named MFC2. The fibrils have been evaluated in regard to how the fibrils react with mortars in both its fresh and hardened state. Tests have been conducted on the use of concrete equivalent mortars with a maximum aggregates size of 4 mm. Two water-cement-ratios have been used in the tests, 0.45 and 0.60. Three different fibril dosages have been tested, 1, 2 and 3 kg/m³. The results of these trials of cellulose fibrils has been evaluated in respect of rheology, compressive strength, flexural strength, cracking, shrinkage, water capillary porosity, anti-wash out resistance (underwater concrete) and as a possible surface coverage. The results from the trials, conducted in this report, show that an increased dosage of fibrils leads to an increased plastic viscosity. The fibrils appear to have no effect on the flexural- and compressive strength, and no effect on the shrinkage of the test specimens. According to our results it is not advisable to use the fibrils for the purpose of acting as an agent for anti-washout resistance, or as a surface coverage. The work have been performed at Swedish Cement and Concrete Research Institute, CBI, in Stockholm in the spring of 2011. CBI is an institution whose mission is to create, apply and disseminate knowledge in the concrete and rock area. / Ett tidigare pilotprojekt har under 2010 utförts på CBI, och där undersöktes möjligheten för cellulosafibrer från skogsindustrin att fungera som Viscosity Modifying Agent (VMA) i betong. Utrymmet i detta projekt var dock för begränsat för att finna svar för optimal användning av denna typ av material. Nu vill skogsindustriföretaget Stora Enso ta reda på om massa från deras träprodukter kan användas i betong, för att på något sätt förbättra dess egenskaper. Vi har därför provat suspensioner innehållande två olika fraktioner av cellulosafibriller. De testade fibrerna finns i två storlekar, det finare materialet heter MFC1 och har genomgått med homogenisering än det grövre materialer som heter MFC2. Dessa två typer har tillsats i bruk och utvärderats i hur de reagerar i både brukets färska och dess hårdnade tillstånd. Testerna har genomförts på bruk med en maximal ballaststorlek på 4 mm. Två vct-nivåer har använts i försöken, 0,45 och 0,60. Tre olika fibrilldoser har prövats, nämligen 1, 2 och 3 kg/m³ fibriller. Resultaten från dessa försök av cellulosafibriller har utvärderats med avseende på reologi, tryckhållfasthet, böjhållfasthet, sprickbildning, kapillaritet, krympning, anti-urvaskning och som möjlig ytbetäckning. De tester som har genomförts visar att med ökad dos fibriller ökar den plastiska viskositeten. Fibrillerna visade sig inte ha någon effekt på böj- eller tryckhållfasheten, samt ingen effekt på krympning av provkropparna. Testerna visar att fibrillerna inte heller agerar med någon possitiv effekt som anti-urvaskningsmedel, eller som ett täckande ytskikt. Försöken har genomförts vid CBI Betonginstitutet i Stockholm mellan 21 mars och 8 juli år 2011.CBI är en institution vars uppdrag är att skapa, tillämpa och sprida kunskap inom betong och bergområdet.
|
242 |
Shear Capacity of Steel Fibre Reinforced Concrete Beams without Conventional Shear ReinforcementMondo, Eleonora January 2011 (has links)
While the increase in shear strength of Steel Fibre Reinforced Concrete (SFRC) is well recognized, it has yet to be found common application of this material in building structures and there is no existing national standard that treats SFRC in a systematic manner. The aim of the diploma work is to investigate the shear strength of fibre reinforced concrete beams and the available test data and analyse the latter against the mostpromising equations available in the literature. The equations investigated are:Narayanan and Darwish’s formula, the German, the RILEM and the Italian guidelines. Thirty articles, selected among over one hundred articles taken from literature, have been used to create the database that contains almost 600 beams tested in shear. This large number of beams has been decreased to 371 excluding all those beams and test that do not fall within the limitation stated for this thesis. Narayanan and Darwish’s formula can be utilized every time that the fibre percentage, the type of fibres, the beam dimensions, the flexural reinforcement and the concrete strength class have been defined. On the opposite, the parameters introduced in the German, the RILEM and the Italian guidelines always require a further characterization of the concrete (with bending test) in order to describe the post‐cracking behaviour. The parameters involved in the guidelines are the residual flexural tensile strengths according to the different test set‐ups. A method for predicting the residual flexural tensile strength from the knowledge of the fibre properties, the cylindrical compressive strength of the concrete and the amount of fibres percentage is suggested. The predictions of the shear strength, obtained using the proposed method for the residual flexural tensile strength, showed to be satisfactory when compared with the experimental results. A comparison among the aforementioned equations corroborate the validity of the empirical formulations proposed by Narayanan and Darwish nevertheless only the other equations provide a realistic assessments of the strength, toughness and ductility of structural elements subjected to shear loading. Over the three investigated equations, which work with the post‐cracking characterization of the material, the Italian guideline proposal is the one that, due to its wide domain of validity and the results obtained for the gathered database of beams, has been selected as the most reliable equation.
|
243 |
Behaviour and design of direct-formed hollow structural section membersTayyebi, Kamran 06 July 2021 (has links)
In North America, cold-formed square and rectangular hollow sections (collectively referred to as RHS hereinafter) of commonly specified cross-sectional dimensions are produced using either the indirect-forming approach or the direct-forming approach. The indirect-forming approach, as the conventional approach of the two, consists of three steps: (i) roll-forming the coil material progressively into a circular hollow section; (ii) closing the section using electric resistance welding (ERW); and (iii) reshaping the circular section into the final square or rectangular shape. On the other hand, the direct-forming approach, as the new approach of the two, roll-forms the coil material directly into the final square or rectangular shape.
RHS with similar cross-sectional dimensions but different production histories (i.e., different cold-forming approaches and post-production treatments) are expected to have significantly different material and residual stress properties. However, RHS design provisions in the existing North American steel design standards (AISC 360-16 and CSA S16-19) are in general developed based on research on indirect-formed RHS and currently do not differentiate RHS cold-formed by different approaches. Based on the research presented in Chapter 1 of this thesis, comparing to indirect-formed RHS, direct-formed RHS in general contain lower levels of residual stresses around cross sections, since the flat faces are not severely cold worked during production. This in turn affects member behaviours under compressive and flexural loadings. The test results presented in Chapters 2 and 4 show that direct-formed RHS have superior stub column and beam behaviours, comparing to their indirect-formed counterparts. In particular, the stub column and beam testing programs, covering a wide range of cross-section dimensions and two strength grades (nominal yield stresses of 350 and 690 MPa), show that the slenderness limits in the existing North American steel design standards are excessively conservative for direct-formed RHS, resulting in unnecessary penalty and member strength underestimation. As a result, the existing design formulae are not suitable for direct-formed RHS. In response to this, subsequent finite element (FE) parametric investigations are performed and presented in Chapters 3 and 5. Modified stub column and beam design recommendations for direct-formed regular- and high-strength RHS are proposed.
The effects of post-cold-forming hot-dip galvanizing on material properties, residual stresses, stub column behaviours and beam behaviours of direct-formed regular- and high-strength RHS are also studied in Chapters 1-5 of this thesis. Similar to the application of the heat treatment per ASTM A1085 Supplement S1 or the Class H finish per CSA G40.20/G40.21, post-cold-forming galvanizing improves the stub column (Chapter 2) and beam (Chapter 4) behaviours of direct-formed RHS via effective reduction of residual stresses (Chapter 1). Based on subsequent FE parametric investigations, modified stub column and beam design recommendations catering to galvanized direct-formed RHS are proposed in Chapters 3 and 5. / Graduate
|
244 |
Lateral Stability Analysis of Precast Prestressed Bridge Girders During All Phases of ConstructionSathiraju, Venkata Sai Surya Praneeth 25 July 2019 (has links)
No description available.
|
245 |
Study on Epoxidized Poly (Styrene-butadiene-styrene) Modified Epoxy ResinsWu, Jiawei January 2019 (has links)
No description available.
|
246 |
Krouse Fatigue for Metals with Elevated Mean StressWilliams, Zachary January 2020 (has links)
No description available.
|
247 |
Böjhållfastheten hos flerskiktade zirkoniamaterial beroende på sintringsprogram / Flexural strength of a multilayer zirconia depending on the sintering programTusoh, Anisa, Bischof Tillström, Johanna January 2022 (has links)
Aim: The aim of the present study was to evaluate how the material KATANA ™ Zirconia YML is affected in strength depending on two different sintering programs. The evaluation of the strength was made by means of a biaxial flexural strength test. Material and method: A total of 48 test specimens, 32 specimens were produced by KATANA ™ Zirconia YML and 16 specimen cups that formed the control group, by KATANA ™. Zirconia UTML. The specimens were designed as circular disks and were placed in two different layers in the disk, between Enamel-Body 1 and Body 2-Body 3. The specimens were divided into two subgroups of which 24 specimens were quickly sintered and the remaining (n = 24) specimens were conventionally sintered and the strength was evaluated with a biaxial flexural strength test. Results: The highest mean value for the biaxial flexural strength test was shown by the test group which was high-speed sintered, with placement in Body 2 - Body 3. This was significant in comparison with other groups (p> 0.001) in addition to conventional sintered with the same placement in the disk. Both control groups showed low mean values in comparison with the test groups, control group K (414 MPa) as the lowest in comparison with all other groups. When comparing the two control groups S and K, no significant difference was shown. Conclusion: The bending strength varies depending on which layers are loaded regardless of fast and conventional sintering. The sintering parameters are significant for the bending strength. / Syfte: Syftet med föreliggande studie var att utvärdera hur materialet KATANA™ Zirconia YML påverkas i hållfasthet beroende av två olika sintringsprogram. Utvärderingen av hållfastheten gjordes med hjälp av ett biaxialt böjhållfasthetstest. Material och metod: Totalt framställdes 48 provkroppar, 32 stycken framställdes av KATANA™ Zirconia YML och 16 provkoppar som utgjorde kontrollgrupp, av KATANA™. Zirconia UTML. Provkropparna var utformade som cirkulära diskar och dem placerades i två olika skikt i disken, mellan Enamel-Body 1 och Body 2-Body 3. Provkropparna delades in i två undergrupper varav 24 provkroppar snabbsintrades och resterande (n=24) provkroppar sintrades konventionellt och hållfastheten utvärderades med ett biaxialt böjhållfasthetstest. Resultat: Högst medelvärde för det biaxiala böjhållfasthetstestet uppvisade testgruppen som snabbsintrats, med placering i Body 2 – Body 3. Detta var signifikant i jämförelse med övriga grupper (p > 0,001) förutom konventionellt sintrat med samma placering i disken. Båda kontrollgrupperna uppvisade låga medelvärden i jämförelse med testgrupperna, kontrollgrupp K (414 MPa) som lägst i jämförelse med alla övriga grupper. Vid jämförelse mellan de två kontrollgrupperna S och K uppvisades inte någon signifikant skillnad. Slutsats: Böjhållfastheten varierar beroende på vilka skikt som belastas oavsett snabb- respektive konventionell sintring. Sintringsparametrarna är betydande för böjhållfastheten.
|
248 |
The effect of a novel photoinitiator system (RAP) on dental resin composites' flexural strength, polymerization stress, and degree of conversionSchaub, Kellie January 2009 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Objectives: A new technology has been introduced into the field of dental resin composites that professes to enhance light-curing efficiency. Rapid amplified photopolymerization (RAP) initiator technology has not yet been fully compared with resin composites with conventional initiators such as camphorquinone (CQ). The purpose of this study was to compare and contrast the effects of this novel technology (RAP) on properties of two light-cured resin composites. Flowable (EFQ) and microfilled (ESQ) experimental composites were fabricated and supplied from Tokuyama Dental with (w/RAP) and without RAP (w/o RAP). The flexural strength (MPa) and flexural modulus (MPa) were obtained using a three-point bending apparatus (Sintech Renew 1123, Instron Engineering Corp., Canton, MA). Polymerization stress curves were created using a tensometer (American Dental Association Health Foundation, NIST, Gaithersburg, MD) which were then used to calculate the maximum stress rate. Finally, the degree of conversion was measured using infrared spectroscopy (Jassco FT-IR spectrometer, Model: 4100, Jasco Corporation, Tokyo, Japan). When evaluating the flexural strength, the peak stress for EFQ w/RAP was significantly higher than EFQ w/o RAP (p = 0.0001). This was statistically not significant for the ESQ group, even though ESQ w/RAP did have a higher peak stress then ESQ w/o RAP (p = 0.28). The interaction between resin type and RAP was not significant when evaluating the flexural modulus (p = 0.21). Formulations with RAP had a significantly higher flexural modulus then w/o RAP (p = 0.0001). Experimental resins with RAP had significantly higher maximum stress rates than those w/o RAP when evaluating polymerization stress (p = 0.0001). Finally, groups w/ RAP appeared to have a higher degree of conversion than groups without (p = 0.0057). This study showed that the experimental composites with RAP had greater mechanical properties than those without. Unfortunately, the increase in polymerization stress causes concern clinically due to the chance of leakage at the restoration/tooth interface. One of the main potential disadvantages of this new RAP technology is an increase in the polymerization stress. Deciding if this amount of polymerization stress is clinically acceptable is yet to be accomplished.
|
249 |
Structural Properties of ICLT Wall Panels Composed of Beetle Killed WoodWilson, David Edward 06 June 2012 (has links) (PDF)
Interlocking Cross Laminated Timber (ICLT) wall panels are a new wood construction product similar to Cross Laminated Timber panels. Besides being an innovative structural system, they also utilize beetle killed timber from many of the forests that have been devastated by the Mountain Pine Beetle. Three tests were performed on three ply ICLT panels measuring 8 feet (2.44m) wide, 8 feet (2.44m) tall and 8.5 inches (21.6cm) thick to determine the racking, flexural and axial strengths of the wall panels. After each test was performed the walls were disassembled and investigated for cause of failure. Using the data from the tests as a benchmark, simple analytical models to predict the design capacities of the walls for racking, flexural, and axial strengths were established. The analytical models for racking strength, flexural strength and axial strength predicted reasonably well the measured strength values. Additional testing is necessary to increase the available database, further validate the analytical models developed, better understand the structural performance of ICLT panels, and establish acceptable design methodology for ICLT wall panels.
|
250 |
Flexural behavior of ECC–concrete hybrid composite beams reinforced with FRP and steel barsGe, W-J., Ashour, Ashraf, Yu, J., Gao, P., Cao, D-F., Cai, C., Ji, X. 09 November 2018 (has links)
Yes / This paper aims to investigate the flexural behavior of engineered cementitious composite (ECC)-concrete hybrid composite beams reinforced with fiber reinforced polymer (FRP) bars and steel bars. Thirty two hybrid reinforced composite beams having various ECC height replacement ratio and combinations of FRP and steel reinforcements were experimentally tested to failure in flexure. Test results showed that cracking, yield and ultimate moments as well as the stiffness of hybrid and ECC beams are improved compared with traditional concrete beams having the same reinforcement, owing to the excellent tensile properties of ECC materials. The average crack spacing and width decrease with the increase of ECC height replacement ratio. The ductility of hybrid reinforced composite beams is higher than that of traditional reinforced concrete beams while their practical reinforcement ratios are similar. Reinforced ECC beams show considerable energy dissipation capacity owing to ECC’s excellent deformation ability. Considering the constitutive models of materials, compatibility and equilibrium conditions, formulas for the prediction of cracking, yield and ultimate moments as well as deflections of hybrid reinforced ECC-concrete composite beams are developed. The proposed formulas are in good agreement with the experimental results. A comprehensive parametric analysis is, then, conducted to illustrate the effect of reinforcement, ECC and concrete properties on the moment capacity, curvature, ductility and energy dissipation of composite beams. / National Natural Science Foundation of China (51678514, 51308490), the Natural Science Foundation of Jiangsu Province, China (BK20130450), Six Talent Peaks Project of Jiangsu Province (JZ-038, 2016), Graduate Practice Innovation Project of Jiangsu Province (SJCX17-0625), the Jiangsu Government Scholarship for Overseas Studies and Top-level Talents Support Project of Yangzhou University
|
Page generated in 0.0615 seconds