Spelling suggestions: "subject:"fratura""
11 |
Avaliação da fadiga por rotação em instrumentos rotatórios exploratórios com diferentes tratamentos térmicos de níquel-titânio(NITI)Viana, Luiz Carlos Trevia Morais Correia 14 July 2017 (has links)
Made available in DSpace on 2019-03-30T00:26:18Z (GMT). No. of bitstreams: 0
Previous issue date: 2017-07-14 / Introduction: The aim of the present study was to compare the cyclic fatigue resistance of rotary pathfinding instruments made of nickel-titanium (NiTi) alloys submitted to different heat-treatments. Methods: Eighty NiTi endodontic files were used. The study groups were composed of Scout Race 15.02 (FKG Deintaire SA), Pathfile 19.02 (Dentsply Maillefer, Ballaigues, Switzerland), Proglider 16.02 (Dentsply Maillefer, Ballaigues, Switzerland), and Hyflex GPS 20.02 (Coltène Whaledent, Allstatten, Switzerland) instruments, which were subjected to cyclic fatigue testing using simulated canals with 6 mm radius and 30° and 45° curvature angles. The data obtained were organized in an Excel spreadsheet and analyzed statistically using BioEstat 5.3 software (Marimauá Institute, Manaus, Brazil). The nonparametric Kruskal-Wallis test was used for... and the Mann-Whitney U-test was used for multiple comparisons, at a significance level of 5%. Results: The Hyflex instrument was superior to all the other instruments (p < 0.05), and Pathfile had a superior fatigue time (p < 0.05) compared to Scout Race and Proglider, for both curvature angles analyzed. No significant difference was observed between Scout Race and Proglider. Conclusion: Cyclic fatigue resistance of the HyFlex GPF instrument was the highest among the instruments tested, and the curvature had a significant effect on fatigue resistance. A significant decrease in the time of cyclic fatigue was observed with an increase in flexion (curvature angle),irrespective of the instrument analyzed. / O presente estudo propôs a comparação da resistência da fadiga por rotação em limas exploratórias rotatórias com diferentes tratamento térmicos de níquel-titânio(NITI). Metodologia: Para conduzir esse experimento, foram utilizadas 80 limas endodônticas de NITI. Foram escolhidas as limas: Scout Race 15.02 (FKG Deintaire SA), Pathfile 19.02 (Dentsply Maillefer, Ballaigues, Suíça), Proglider 16.02 (Dentsply Maillefer, Ballaigues, Suíça), Hyflex GPS 20.02 (Coltène Whaledent, Allstatten, Suíça). Os grupos foram submetidos ao teste de fadiga cíclica através de dispositivos que simulam raio de 6 mm e ângulos de curvatura de 30° e 45°. Todas as limas foram acionadas até que ocorresse a fratura visual das mesmas, sendo o tempo entre o início de funcionamento até a fratura de cada instrumento protocolado através de um cronômetro 1/100 segundos e tabulado, registrado por apenas um avaliador. Os dados obtidos foram organizados em planilhas de Excel e analisados estatisticamente com o auxílio do software BioEstat 5.3(Instituto Marimauá, Manaus, Brasil). Tendo em vista as diferenças significativas entre os resultados dos grupos, foi utilizado o teste não-paramétrico Kruskal-Wallis. O teste U de Mann-Whitney foi utilizado para comparações múltiplas, utilizando-se o nível de significância de 5%. Resultados: De acordo com os resultados analisados, pode-se notar que o aumento da flexão(angulação) promoveu significativa diminuição do tempo de fadiga cíclica, independentemente do grupo analisado(p<0,05). O instrumento Hyflex obteve resultado superior em relação aos demais, independentemente da flexão sob análise. Na sequência, em ambas as flexões analisadas, o instrumento Pathfile apresentou tempo de fadiga superior(p <0.05) em relação aos instrumentos Scout Race e Proglider. Os instrumentos Scout Race e Proglider não apresentaram diferenças estatisticamente significativas entre si. Conclusão: A lima Hyflex GPF apresentou, estatisticamente, maior resistência à fadiga cíclica em comparação com as outras limas utilizadas na metodologia, independente do grau de curvatura utilizado. Houve uma diminuição significativa no tempo de fadiga cíclica com o aumento do ângulo da curvatura.
|
12 |
Efeito da chalcona (Myracroduon Urundeuva Fr. All.) nas fraturas expostas induzidas em ratos / The effect of chalconas on induced exposed fractures in ratsMota, Carlos Windson Cavalcante January 2006 (has links)
MOTA, Carlos Windson Cavalcante. Efeito da Chalcona (Myracroduon Urundeuva Fr. All.) nas fraturas expostas induzidas em ratos. 2006. 65 f. Dissertação (Mestrado em Cirurgia) - Universidade Federal do Ceará. Faculdade de Medicina, Fortaleza, 2006. / Submitted by denise santos (denise.santos@ufc.br) on 2014-02-18T12:41:18Z
No. of bitstreams: 1
2006_dis_cwcmota.pdf: 642116 bytes, checksum: 6ab81fa88af4da3624ec8d5fe3464344 (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2014-02-18T12:41:40Z (GMT) No. of bitstreams: 1
2006_dis_cwcmota.pdf: 642116 bytes, checksum: 6ab81fa88af4da3624ec8d5fe3464344 (MD5) / Made available in DSpace on 2014-02-18T12:41:40Z (GMT). No. of bitstreams: 1
2006_dis_cwcmota.pdf: 642116 bytes, checksum: 6ab81fa88af4da3624ec8d5fe3464344 (MD5)
Previous issue date: 2006 / A chalcona é um complexo fitoterápico derivado da aroeira-do-sertão (Myracrodruon urundeuva Fr. All.), planta usada popularmente como antiinflamatório e cicatrizante. Avaliaram-se os efeitos anti-sépticos e cicatrizantes das chalconas nas feridas e o seu efeito sobre a consolidação óssea nas fraturas expostas induzidas em ratos. Utilizaram-se ratos Wistar machos adultos, com peso médio de 300g. A fratura foi realizada no fêmur esquerdo dos animais e exposta por 3h antes de iniciar o tratamento. Os animais foram distribuídos ao acaso em dois grupos: o grupo 1 o foco da fratura foi limpo com 100 mL de soro fisiológico 0,9% e o grupo 2, o foco da fratura foi limpo com 100 mL de soro fisiológico 0,9% e 40 mL de chalconas, na concentração de 10 mg de chalcona por 1 mL de solução salina a 0,9%. Em todos os animais foram realizadas culturas dos focos de fraturas antes de iniciar o tratamento que consistiu na osteosíntese intramedular com fio de Kirschener de 1 mm de diâmetro. Foi realizada a avaliação clínica e radiológica no pós-operatório imediato, no 7º, 14º, 21º e 28º dias do tratamento. Na avaliação clínica verificava-se o aspecto da ferida: sinais flogísticos, deiscência da ferida, fístula e ferida cicatrizada. No primeiro grupo, a cicatrização ocorreu após a 3º semana em 78,9 % dos animais; no segundo grupo, a cicatrização ocorreu a partir da 2º semana em 50 % dos ratos. Em todos os animais ocorreram contaminações, sendo o Staphylococcus aureus o microorganismo isolado mais comumente. No primeiro grupo, 80% dos animais perderam a redução na segunda semana, e no segundo grupo, 50% dos animais perderam a redução na terceira semana. Conclui-se que a chalcona na concentração testada não tem efeito na consolidação da fratura exposta induzida em rato, porém é benéfica na cicatrização da ferida operatória.
|
13 |
Comparação biomecânica entre duas montagens de fixação externa circular híbrida para tratamento de fraturas do planalto tibialCardoso, Gracielle Silva January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Ciências Médicas, Florianópolis, 2015. / Made available in DSpace on 2016-04-19T04:06:45Z (GMT). No. of bitstreams: 1
337781.pdf: 1720160 bytes, checksum: 3b1dc1053639649a7d0ef91ff938e466 (MD5)
Previous issue date: 2015 / Introdução: Fraturas do planalto tibial de alta energia seguem sendo um dos grandes desafios da traumatologia ortopédica, sendo que ainda existe muita controvérsia no que concerne o seu tratamento. Dentre as possibilidades de tratamento, a abordagem mínima associada à fixação externa tem gerado interesse nos últimos anos. Objetivo: Comparar o desvio interfragmentário entre duas diferentes montagens de fixação circular híbrida de Ilizarov utilizadas para tratamento de fraturas de alta energia do planalto tibial por meio de ensaios biomecânicos. Materiais e Métodos: Dois diferentes grupos de montagens de fixação circular híbridas, respeitando as restrições anatômicas locais, foram realizadas em tíbias compósitas osteotomizadas em sua metáfise proximal simulando fraturas do planalto tibial com dissociação metáfiso-diafisária. A montagem padrão foi realizada conforme descrito por Catagni-Cattaneo e a montagem teste foi realizada substituindo-se os fios Kirschner distais por pinos de Schanz. Ambos os grupos foram submetidos a ensaios biomecânicos com carga axial cíclica variando entre 300 N e 1.000 N por 10.000 ciclos. Foram analisados os desvios e as rotações interfragmentários. Resultados e Discussão: A montagem padrão se comportou de forma semelhante a uma montagem de Ilizarov clássica, permitindo um maior movimento axial (eixo Y) e um menor movimento angular látero-lateral (eixo X) quando comparada com a montagem teste. Enquanto a montagem teste apresentou um comportamento mais semelhante ao observado em fixadores externos lineares, proporcionando uma estabilidade axial (eixo Y) superior à observada na montagem padrão, uma estabilidade ântero-posterior (eixo Z) semelhante entre os dois grupos e uma menor estabilidade látero-lateral (eixo X). Apesar dessas diferenças, em ambos os grupos de montagens o deslocamento axial sobrepujou os deslocamentos nos demais eixos. Conclusão: O aumento do número de pinos de Schanz e a diminuição do número de fios de Kirschner em montagens de fixação circular hibrida gerou montagens com comportamento mecânico tendendo ao dos fixadores externos lineares.<br> / Abstract : Introduction: High-energy tibial plateau fractures remain as one of the greatest challenges of orthopedic traumatology, it still gives rise to controversy in what concerns treatment, especially when approaching fractures with metaphysio-diaphyseal dissociation. Treatment with percutaneous or minimal direct reduction associated with circular external fixation has recently generated interest, although there is no consensus among the type of external fixation to be used. Objective: Compare the interfragmentary displacement between to different hybrid circular external fixation mountings used to treat high-energy tibial plateau fractures through biomechanical testing by cyclic axial loading.Material and Methods: Two different groups of hybrid circular external fixation frame mountings respecting anatomical restrictions were assembled, using composite tibiae with proximal metaphysary osteotomies simulating tibial plateau fractures with metaphysio-diaphyseal dissociation. Standard frame mounting was assembled as described by Catagni-Cattaneo and test frame mounting was assembled replacing the distal Kirschner wires by half-pins. Both groups were biomechanically tested through cyclic loading between 300 N and 1,000 N for 10,000 cycles. Interfragmentary rotational and angular displacements were analyzed. Results and Discussion: Standard frame mounting behaved similarly to a classic Ilizarov frame, allowing a greater axial movement and a smaller latero-lateral angular displacement when compared with the test frame. While the test frame behaved more similarly to a linear external fixator, providing greater axial stability, similar angular antero-posterior displacement and lower angular latero-lateral stability. In despite of these differences, in both frame mounting groups the axial displacement was greater then the prejudicial non-axial movements. Conclusion: Increasing the number of half-pins and diminishing the number of Kirschner wires in hybrid circular external fixation generated frames that tend to behave more similarly to linear external fixators.
|
14 |
Densidade mineral óssea nas fraturas do fêmur proximalBolze, Carlos Daniel de Garcia January 2013 (has links)
Made available in DSpace on 2013-10-11T13:36:02Z (GMT). No. of bitstreams: 1
000451530-Texto+Completo-0.pdf: 874480 bytes, checksum: 4b9f9513f629e3b1ebc54424e63744f8 (MD5)
Previous issue date: 2013 / Osteoporotic fractures always bring morbidity to patients and in the proximal femur, also mortality. International studies have sought to examine the relationship between bone mineral density and hip fractures; however, Brazil and Latin America still need more data. This study aims to describe the bone quality of patients who suffered fractures of the proximal femur treated at a hospital in southern Brazil and make a comparative analysis according to gender, BMI and the different types of fractures. Patients and Methods: We analyzed in a transversal study 118 patients with proximal femur fractures, 56 with femoral neck fractures and 62 with trochanteric fractures. Of these, 16 were male and 102 female. Femoral neck fractures were classified according to the classification of Garden and later divided into Stable (Garden I and II) and Unstable (Garden III and IV). The trochanteric fractures were classified according to AO-OTA and divided into Stable (31A1 up to 31A2. 1) and Unstable (31A2. 2 up to 31A3. 3).Results: Fractures classified as Stable showed T-score values lower than those unstable for all measurement locations in the proximal femur. Statistical significance was detected in the difference between the measurements obtained in the trochanteric region and the spine (p = 0. 042 and p = 0. 024 respectively) when comparing unstable trochanteric and femoral neck factures. Trochanteric fractures tend to occur in patients above 80 years old while cervical fractures are more frequent above 70 years old. Patients with trochanteric fractures had lower BMI than those with fractures of the femoral neck (p = 0. 022).Conclusion: The trochanteric fractures tend to occur in older patients and are associated with the BMI lower than those patients with femoral neck fractures. Unstable fractures have higher bone mineral loss in the trochanteric region, which may indicate greater loss in this region with advancing age, favoring the occurrence of trochanteric fractures. / As fraturas osteoporóticas sempre trazem morbidade aos pacientes e, no fêmur proximal, também, mortalidade. Estudos internacionais têm procurado analisar as relações entre a densidade mineral óssea e as fraturas do quadril, entretanto, o cenário brasileiro e latino-americano, ainda, carece de mais dados. Este estudo visa descrever a qualidade óssea de pacientes que sofreram fraturas do fêmur proximal, tratados em um hospital do sul do Brasil e fazer uma análise comparativa de acordo com o sexo, o IMC e os diferentes tipos de fraturas. Pacientes e Métodos: Em um estudo transversal foram analisados 118 pacientes sendo 56, com fraturas do Colo do Fêmur e 62, com fraturas Trocantéricas em. Destes, 16 foram do sexo masculino e 102 do sexo feminino. As fraturas do colo do fêmur foram classificadas de acordo com a classificação de Garden e, posteriormente divididas em Estáveis (Garden I e II) e Instáveis (Garden III e IV). As fraturas trocantéricas foram classificadas de acordo com a classificação AO-OTA e divididas em Estáveis (31A1 até 31A2. 1) e Instáveis (31A2. 2 até 31A3. 3).Resultados: As fraturas classificadas como Estáveis apresentaram valores T-Score menores do que as Instáveis em todos os sítios de medição do fêmur proximal. Foi detectada significância estatística na diferença entre as medidas obtidas na região trocantérica e coluna vertebral (p=0,042 e p=0,024, respectivamente) na comparação das Fraturas Trocantéricas e do Colo do Fêmur Instáveis. As fraturas trocantéricas tendem a ocorrer em pacientes acima de 80 anos e as fraturas do colo do fêmur em pacientes abaixo dos 70 anos. Os portadores de fraturas trocantéricas apresentaram IMC menor que os portadores de fraturas do colo do fêmur (p=0,022).Conclusão: As fraturas trocantéricas tendem a ocorrer em pacientes em idade mais avançada e estão associadas a IMC menor que os portadores de fraturas do colo femoral. As fraturas trocantéricas instáveis apresentaram maior perda mineral óssea na região trocantérica em relação aos pacientes com fratura do colo do femur, o que pode indicar maior perda, nessa região, com o avanço da idade, favorecendo a ocorrência das fraturas trocantéricas.
|
15 |
Analise retrospectiva dos traumas faciais decorrentes de acidentes de transito em pacientes atendidos pela area de Cirurgia Buco-maxilo-facial da Faculdade de Odontologia de Piracicaba/UNICAMP no periodo de 1999 a 2007 / Retrospective analysis of facial traumas due to traffic accidents in patients received ath the Oral and Maxilofacial Surgery Division of Piracicaba Dental Scholol - State University of Campinas between 1999 and 2007Borba, Marcia Socorro da Costa 02 January 2010 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T03:01:23Z (GMT). No. of bitstreams: 1
Borba_MarciaSocorrodaCosta_D.pdf: 1004197 bytes, checksum: 9f2ecac6dba7f1ca081875b1eb4a4ea2 (MD5)
Previous issue date: 2010 / Resumo: O presente estudo retrospectivo teve por objetivo avaliar a complexidade dos traumatismos faciais decorrentes de acidente de trânsito considerando diagnóstico, tratamento e complicações e relacioná-los com o uso de dispositivos de segurança. Os dados foram coletados dos prontuários do arquivo da Área de Cirurgia Buco-Maxilo-Facial da Faculdade de Odontologia de Piracicaba/Unicamp no período de 1999 a 2007. A amostra foi de 657 pacientes dos quais 76,7% foram vítimas de acidente automobilístico e 23,3% de acidente motociclístico. Pacientes do gênero masculino e na faixa etária de 18 a 30 anos (63,7%) sofreram um maior número de acidentes de trânsito. Quanto à utilização do dispositivo de segurança de trânsito foi mais freqüente no gênero masculino e entre os motociclistas (73,8%). O tipo de trauma facial mais freqüente foram as fraturas ósseas (68,6%) localizadas no terço médio e na mandíbula. Em relação aos traumas associados à outros órgãos observou-se uma maior associação entre os traumas faciais e traumas ortopédicos, verificando-se uma maior freqüência (60,7%) em pacientes que não estavam utilizando nenhum tipo de dispositivos de segurança. O tratamento conservador foi o mais aplicado em 70,5% dos pacientes e a infecção foi a complicação mais freqüente. Os acidentes de trânsito ocorreram com maior freqüência nos pacientes adultos jovens do gênero masculino e os traumas de face associados a de outros órgãos quando as vítimas não estavam utilizando dispositivo de segurança. Dessa forma as campanhas educacionais e preventivas devem ser direcionadas para este público / Abstract: This retrospective study had as aim to evaluate the complexity of facial trauma due to traffic accident, considering diagnosis, treatment and complications and to relate them to the use of safety tools. The data were collected from the patient files of the department of Oral and Maxillo Facial Surgery in the Piracicaba/Unicamp Dental School in the period of 1999 to 2007. The sample consisted of 657 patients from wich 76,7% were car accident victms and 23,3% were motorcycle accident victms. Male Patients in the age range of 18 to 30 years old (63,7%) suffered a higher number of traffic accidents. Regarding to the use of traffic safety tools, the frequency was higher for male motorcycle users (73,8%). The most frequent types of facial trauma were bone fracture (68, 6%) located in the middle third of the face and mandible. Regarding to the trauma associated to other organs, it was observed a higher association between facial trauma and orthopedic trauma, with a higher frequency (60, 6%) in patients without safety traffic tools. The most applied treatment was the conservative in 70,5% of the patients and infection was the most frequent complication. The traffic accidents happened in a higher frequency in male young adults and the facial trauma associated to other organs occurred when the victims did not used safety tolls. Thus, preventive and educational campaigns should be targeted to this public / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
|
16 |
Avaliação fonoaudiologica das fraturas zigomatico-orbitarias / Phonoaudiologic evaluation of the zygomatic orbital fracturesUguetto, Michelle Karine 12 July 2007 (has links)
Orientador: Mario Mantovani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-11T18:28:45Z (GMT). No. of bitstreams: 1
Uguetto_MichelleKarine_M.pdf: 2245684 bytes, checksum: f80e585c54205749099401755d914d88 (MD5)
Previous issue date: 2007 / Resumo: O presente trabalho teve como objetivo, através de um protocolo, avaliar as alterações fonoaudiológicas decorrentes de fraturas zigomático-orbitárias, relacionando-as às disfunções do sistema estomatognático, em relação ao gênero, idade, cor, biomecânica do trauma, tipo de fratura, sinais e sintomas e tratamento cirúrgico definitivo. A amostra foi composta por 40 indivíduos traumatizados com fraturas unilaterais zigomático-orbitárias, sendo 20 pacientes com fraturas de zigoma e 20 de assoalho, que foram submetidos à avaliação fonoaudiológica e seus resultados foram analisados através de exames clínicos de estrutura e funções do sistema estomatognático que compunham o protocolo. O presente estudo demonstrou, segundo a amostra avaliada, que as fraturas zigomático-orbitárias foram mais prevalentes entre adultos jovens, entre 31 a 40 anos, brancos, do sexo masculino, em eventos ligados ao trânsito, sendo o lado esquerdo mais acometido e o tratamento cirúrgico foi mais realizado em detrimento do conservador. As funções de respiração, deglutição e fala apresentaram-se mais alteradas nas fraturas de zigoma, enquanto que as alterações da mímica facial, mastigação estavam mais alteradas nas fraturas de assoalho / Abstract: The aim of this study was to evaluate the phonoaudiologic alterations of the zygomatic orbital fractures, relating this manifestations to stomatognatic system dysfunctions to sex, age, skin, trauma¿s biomechanics, kind of fracture, signals and symptoms and surgical treatment, using a evaluation protocol. The sample was composed for 40 individuals with zygomatic orbital fractures, being 20 patients with zygoma fractures and 20 patients with orbital floor fractures, that had been submitted to the phonoaudiologic evaluation and these results had been analyzed through clinical examinations of structure and functions of the stomatognatic system that composed the protocol. The present study demonstrated that the zygomatic orbital fractures had a higher prevalence in young adults, of white skin ranging from 31 to 40 years; in automobilist accidents, with a higher prevalence in left side of zygomatic orbital complex and the surgical treatment was more carried that the conserving surgery. The functions of stomatognatic system, like respiration, swallow and speech were more damaged in zygoma fractures. The facial movement and mastication functions was more damaged in orbital floor fractures / Mestrado / Pesquisa Experimental / Mestre em Cirurgia
|
17 |
Avaliação 'in vitro' da resistência à fratura de cavidades classe II restauradas pela técnica do tratamento restaurador atraumático (ART) / Fracture strength of evaluation in vitro of class II restorations using the Atraumatic Restorative Treatment (ART) techniqueTerezinha de Jesus Esteves Barata 21 May 2003 (has links)
A proposta deste estudo foi avaliar a resistência à fratura (RF) de restaurações classe II (MO ou DO) realizadas pela técnica do Tratamento Restaurador Atraumático (ART); de acordo com a influência: de três variáveis: retenções adicionais nos preparos cavitários (RA-com retenção e AR-sem retenção), método de inserção (SI-seringa injetora e ED-escavador de dentina) e tipo do cimento de ionômero de vidro utilizado (Ketac-Molar /3M ESPE (KM) de alta viscosidade e dois modificados por resina, Fuji VIII/GC (F8)-restaurador e Rely X/3M ESPE (RX) para cimentação). Um total de 120 pré-molares humanos superiores hígidos foram divididos em 12 grupos. Grupo 1: KM(RA+SC), grupo 2: KM(RA+ED), grupo 3: KM(AR+SC), grupo 4: KM(AR+ED), Grupo 5: F8 (RA+SC), grupo 6: F8 (RA+ED), grupo 7: F8 (AR+SC), grupo 8: F8 (AR+ED), Grupo 9: RX (RA+SC), grupo 10: RX (RA+ED), grupo 11: RX (AR+SC), grupo 12: RX(AR+ED). Os dentes restaurados foram armazenados em estufa a 37ºC e 100% de umidade relativa por 24 horas e submetidos ao carregamento axial de compressão em Máquina de Ensaios- Emic a uma velocidade de 0,5 mm/minuto, até que houvesse a fratura da restauração. Os valores obtidos, em Kgf, foram: Grupo 1: 65,66±0,245, grupo 2: 62,58±0,241, grupo 3: 57,11±0,196, grupo 4: 51,94±0,231, Grupo 5: 63,05±0,217, grupo 6: 60,120±0,239, grupo 7: 55,11±0,196, grupo 8: 49,20±0,163, Grupo 9: 50,99±0,246, grupo 10: 48,810±0,255, grupo 11: 45,53±0,266, grupo 12: 41,88±0,304. Os resultados obtidos foram analisados por meio dos testes estatísticos, ANOVA a três critérios (p<0,001) e Tukey, que revelaram uma influência mútua estatisticamente significante entre todas as variáveis analisadas: material x retenção; material x inserção; retenção x inserção; material x retenção x inserção. Todas as situações analisadas influenciaram a resistência à fratura. / The aim of this study was to evaluate in vitro the influence of three variables on the fracture resistance of glass ionomer class II restoration (MO or DO), using the ART technique. The three variables are the material, composed by Ketac-Molar(KM)-3M ESPE,Fuji VIII(F8)-GC and Rely X(RX)-3M ESPE, the presence(PR) or absence of additional retention(AR) and the insertion method, by using a centrix syringe(CS) or an spoon excavator(SE). A total of 120 superior human premolars were divided into to 12 groups. Group 1: KM(PR+CS), group 2: KM(PR+SE), group 3: KM(AR+CS), group 4: KM(AR+SE), Group 5: F8 (PR+CS), group 6: F8(PR+SE), group 7: F8(AR+CS), group 8: F8(AR+SE), Group 9: RX(PR+CS), group 10: RX(PR+SE), group 11: RX(AR+CS), group 12: RX(AR+SE). The specimens were stored in a stove at 37o C and 100% of humidity for 24 hours. After this period, the teeth were submitted to the compressive axial loading in a testing machineEMIC, by 0.5 mm/minute of speed, until the breakdown of the restoration. The mean values plus standard deviations, in Kgf, were: Group 1: 65,66±0,245, group 2: 62,58±0,241, group 3: 57,11±0,196, group 4: 51,94±0,231, Group 5: 63,05±0,217, group 6: 60,120±0,239, group 7:55,11±0,196, group 8: 49,20±0,163, Group 9: 50,99±0,246, group 10:48,810±0,255, group 11: 45,53±0,266, group 12: 41,88±0,304. The results were analyzed by statistic tests, three way ANOVA (p<0,001) and Tukey, revealing a mutual influence statistically significant among all tested variables: material x retention; material x insertion; retention x insertion and material x retention x insertion. All analyzed situations have influenced the fracture strength.
|
18 |
Avaliação biomecânica e fotoelástica da fixação das fraturas de sínfise mandibular usando parafusos canulados cônicos / Biomechanical and photoelastic evaluation of mandibular symphysis fracture fixation with cannulated conical screwsFalci, Saulo Gabriel Moreira, 1983- 02 November 2014 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T16:02:50Z (GMT). No. of bitstreams: 1
Falci_SauloGabrielMoreira_D.pdf: 1799316 bytes, checksum: 1de035c12bc218e5f3759c843bc2025d (MD5)
Previous issue date: 2014 / Resumo: O objetivo desse estudo foi comparar por meio de testes mecânicos e fotoelásticos o desempenho dos parafusos canulados cônicos utilizados na fixação de fraturas de sínfise mandibular com outros métodos de fixação. Dez mandíbulas de poliuretano foram utilizadas em cada grupo e fixadas da seguinte maneira: Grupo (PRP), duas miniplacas do sistema 2,0 mm, perpendiculares; Grupo (PLL), uma placa do sistema 2,4 mm e uma miniplaca do sistema 2,0 mm, paralelas; Grupo (PC), dois parafusos canulados cônicos do sistema 2,8 mm. Foram realizados testes de carregamento linear vertical em uma máquina de ensaio universal. O teste de ANOVA One-way e o teste de Tukey foram utilizados para verificar a diferença entre as médias. O teste fotoelástico foi realizado, com o auxílio de um polariscópio plano. Foi usada uma mandíbula de resina fotoelástica para cada grupo de fixação (PRP, PLL e PC). A avaliação dos dados do teste fotoelástico foi qualitativa e descritiva. Os resultados mostraram diferença entre os grupos (PC) e (PRP) nos deslocamentos de 1 mm (p=0,025), 3 mm (p=0,013), 5 mm (p=0,036) e 10 mm (p=0,022). No teste fotoelástico foi observada maior concentração de tensões na região próxima à base mandibular em todos os grupos. No grupo (PRP) e (PLL) foi observada maior concentração de tensões na região da placa mais próxima à base enquanto no grupo (PC) as franjas isocromáticas foram mais dispersas em toda região avaliada. De acordo com os resultados do estudo foi possível concluir que os parafusos canulados cônicos apresentaram um bom desempenho nos testes mecânicos e fotoelásticos, sendo uma opção viável para a fixação das fraturas de sínfise mandibular / Abstract: The aim of this study was to compare by mechanical and photoelastic tests, the performance of the cannulated screws in mandibular symphysis fractures and compare them with other fixations methods. Ten polyurethane mandibles were used in each group and fixed as follows: Group (PRP) 2 2.0-mm perpendicular miniplates; Group (PLL) 1 2.0-mm miniplate and 1 2.4-mm bone plate, parallels; Group (CS) 2 2.8-mm cannulated screws. Vertical linear loading tests were performed in a universal testing machine. Differences among means were analyzed by the One-Way ANOVA and Tukey test. The photoelastic test was carried out using a plane polariscope. One photoelastic mandible resin was used for each fixation group (PRP, PLL and CS). Data evaluation of the photoelastic test was qualitative and descriptive. The results showed differences between (CS) and (PRP) groups in 1 mm (p=0.025), 3 mm (p=0.013), 5 mm (p=0.036) and 10 mm (p=0.022), of displacement. The photoelastic test showed higher stress concentration, in all groups, close to mandibular base. In (PRP) and (PLL) groups, the stress concentration was observed closest to the plate fixed in mandibular basis, while the (CS) group showed more dispersed isochromatic fringes throughout the evaluated region. According to the results of this study, it was concluded that conical cannulated screws performed well in mechanical and photoelastic test, being a viable method for fixation of mandibular symphysis fractures / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
|
19 |
Tratamento das fraturas da diafise do umero com a placa em ponte : descrição e aplicação da tecnica em 15 pacientesLivani, Bruno 12 March 2001 (has links)
Orientador : William Dias Belangero / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-01T06:22:42Z (GMT). No. of bitstreams: 1
Livani_Bruno_M.pdf: 14969466 bytes, checksum: 607f9ebe10c3a62fa53c7f23889007d2 (MD5)
Previous issue date: 2001 / Resumo: Este estudo desenvolveu-se no período de novembro de 2000 a julho de 2001, no Departamento de Ortopedia e Traumatologia da Faculdade de Ciências Médicas da UNICAMP. Na primeira fase, a via de acesso, a técnica e o tipo da placa foram definidos a partir de estudos em peças anatômicas e em cadáveres. Após a aprovação do Comitê de Ética em Pesquisa e do consentimento formal pós informado, foram tratados todos os pacientes acima de 14 anos de idade que concordaram de livre e espontânea vontade em participar do estudo. Assim, foram operados 15 pacientes sendo 11 do sexo masculino com idade variando de 14 a 66 anos. Todas as fraturas eram unilaterais e em um caso houve necessidade de reoperação, pois o paciente sofreu novo acidente 45 dias após a primeira cirurgia. Dos 15 pacientes, 8 eram poliffaturados ou politraumatizados e dentre esses, 2 tinham fratura exposta. Os demais apresentaram fratura isolada do úmero, dos quais 1 era exposta. Em nenhum paciente houve lesão prévia isolada do nervo radial, mas em 2 pacientes ocorreram lesão do plexo braquial. Em todos os pacientes foi utilizado um acesso proximal entre o músculo deltóide e o músculo bíceps braquial, tanto para as fraturas médio-diafisáriascomo para as distais. Já o acesso distal foi feito entre os músculos bíceps braquial e braquial, no caso das fraturas do terço médio, enquanto que para as fraturas do terço distal o acesso acompanhou a borda lateral da extremidade distal do úmero com exposição sub-periosteal da região anterior da coluna lateral. Todas as fraturas foram fixadas pela técnica em ponte com apenas duas incisões, uma proximal e outra distal ao foco de fratura. Foram utilizadas placas DCP de grandes fragmentos, largas e estreitas, na sua maioria com 12 furos e fixadas com 4 corticais em cada extremidade. Não houve necessidade do uso do intensificador durante o procedimento. Todos os casos consolidaram com um tempo médio de 8 a 12 semanas, com exceção de um caso com fratura exposta lUA de Gustilo e Anderson e lesão do plexo braquial ipsi-lateral. Não houve infecção nem lesão do nervo radial ou de outra estrutura vasculo-nervosa. Todos os pacientes evoluíram com recuperação funcional do membro acometido, sem deformidades residuais significativas / Abstract: This study was developed during november 2000 and july 2001 in the Orthopaedic and Traumatology Department ofUNICAMP. The fust part ofthe study was to define the surgical approach, technique and type of plate from analisys of anatomica1 pieces and cadavers. Afier approval of the Ethical Committee and consensus of the rules -andpatient formalagreementand consent, there were treatedall patients over fourteen years who freellyagreed to take part in the study. There were 15 patients operated upon 11 males, -agebetween 14 and 66 years. All :&actureswere unilater-alandin one case there was
necessity to reoperate because the patient suffered another accident 45 days after the fust surgery. Of the 15 patients 8 were polytraumatized, two ofthemhad openfractures. The others showed isolated fracture of the humerus, which one was open. None of the patient had previous lesion of radiais nerve, OOtin two patient there was lesion of the brachial plexus. To all patients we used the same proximal access between the deltoid musc1eand the biceps brachialisinmiddle shaft and distal third fractures, while the distalaccess to fractures of the middle shaft was made between the muscles biceps brachialis and
br-achialis,while in the distal third it was made following the lateral border of the distal humerus with sub-periosteal exposition of the anterior face of the lateral column. We used broad and narrow D.C.P.@ plates for large fragments mostly with twelve holes, fixed with four corticals screws at each end. There was no need to used image intensifier during the procedure. All cases united with an average time of eight to twelve weeks, with exceptiOl1 to a case with open fracture llIA Gustilo and Anderson and lesion of the same side brachial plexus. Wehad noinfection or lesions to theradial nerve orany other vascular nervous
structures. All patients were recovered with full function of the limb without significant residual deformity / Mestrado / Cirurgia / Mestre em Cirurgia Medica
|
20 |
Aspectos eticos, legais e terapeuticos da fratura de instrumentos endodonticosSilva, Rhonan Ferreira da 26 March 2004 (has links)
Orientadores: Eduardo Daruge Junior, Luiz Francesquini Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T21:51:53Z (GMT). No. of bitstreams: 1
Silva_RhonanFerreirada_M.pdf: 1850591 bytes, checksum: b8d8d688f615516c0e8c95ec2baa35d3 (MD5)
Previous issue date: 2004 / Resumo: A Endodontia encontra-se em pleno desenvolvimento, tornando-se mais automatizada, rápida e acessível tanto para o estudante quanto para o profissional da Odontologia. As diferentes manobras utilizadas para a realização do tratamento endodôntico proporcionam uma grande margem de sucesso neste tipo de tratamento. Entretanto, diversos acidentes podem ocorrer durante o tratamento dos canais radiculares e a fratura de instrumentos endodônticos constitui um dos mais indesejáveis. Este acidente pode ser ocasionado por vários motivos, podendo estar relacionado à fabricação do instrumento, à particularidades da morfologia dos canais e ao modo pelo qual estes instrumentos são utilizados pelo Cirurgião-Dentista. Esse estudo verificou o conhecimento dos Cirurgiões-Dentistas sobre os aspectos técnicos relacionados à fratura de instrumentos endodônticos radiculares, bem como as suas repercussões éticas e legais, no relacionamento profissional-paciente e no relacionamento interprofissional, entre os Cirurgiões-Dentistas que realizam o tratamento endodôntico nos municípios de Goiânia e Aparecida de Goiânia-GO. Para tanto, foram avaliados 200 questionários distribuídos de forma aleatória e os dados obtidos foram agrupados segundo as variáveis classificatórias e segundo a qualificação e atuação dos indivíduos que realizam o tratamento endodôntico. A análise estatística incluiu testes de Qui-quadrado e Exato de Fischer. Os resultados finais demonstraram que 56% dos entrevistados já fraturou algum tipo de instrumento endodôntico e entre os endodontistas, este valor alcançou 87,5%. A fratura ocorreu de uma a cinco vezes, para 46% dos entrevistados. A principal causa de fratura citada foi o uso excessivo do instrumento, sendo apontada por 61% da amostra e por 46,9% dos endodontistas. A falta de conhecimentos técnico-científicos constitui uma das causas de fratura dos instrumentos endodônticos para 39,5% da amostra. 74% dos entrevistados sente a necessidade de um programa de educação continuada sobre acidentes e complicações em Endodontia e 62,5% dos profissionais desconhecia qualquer tipo de técnica visando a retirada do instrumento fraturado. 27% da amostra sugeriu um maior aprofundamento teórico sobre os acidentes decorrentes do tratamento endodôntico, com enfoque odontolegal. Quanto ao esclarecimento prévio sobre os riscos inerentes ao tratamento endodôntico, 59% esclarece verbalmente, 35,5% não esclarece e apenas 20,5% esclarece por escrito. Concluiu-se que os Cirurgiões-Dentistas não estão bem preparados quanto ao conhecimento técnico-científico relativo à fratura de instrumentos endodônticos, especificamente sobre as opões terapêuticas e técnicas utilizadas na retirada do instrumento endodôntico fraturado. Considerando que o uso excessivo do instrumento foi a principal causa de fratura apontada pelos entrevistados, cabe ao Cirurgião-Dentista estabelecer a quantidade de vezes que um mesmo instrumento endodôntico deve ser utilizado, antes de descartá-lo. Tanto os endodontistas quanto os clínicos gerais agem de maneira mais eticamente correta no relacionamento profissional-paciente do que a relação interprofissional e, entre os clínicos gerais pôde ser observada uma postura tida como eticamente correta, quando comparados com os especialistas. Finalmente, conclui-se que a maioria dos entrevistados documenta-se precariamente, ficando vulnerável nos processos judiciais quando é aplicado o Código de Proteção e Defesa do Consumidor. Assim sendo, o Cirurgião-Dentista deve se resguardar de processos judiciais por meio de uma documentação odontológica completa e adequadamente preenchida / Abstract: Nowadays Endodontics is developing, the technique became automated, faster and feasible to students as well to clinicians. Even though different techniques used in endodontic treatment allow great success rate, several accidents may happen during root canal treatment and endodontic instrument fracture is one of the most unpleasant situation. Such accident can be caused by several reasons; it can be related to instrument manufacturing, canal morphology and the way that these instruments are used by dentists. This research verified clinicians knowledge of technical aspects related to endodontic instrument fracture as well ethical and legal consequences in professional/patient and professional/professional relationship. The research was performed among dentists in Goiânia and Aparecida de Goiânia in Goiás State in Brazil. In order to do so, 200 questionnaires were randomly distributed. Statistical analysis included Chi-square and Fisher exact tests. Results showed that 56% had already fractured some type of endodontic instrument and among Endodontists this number increased to 87.5%. The fracture happened from 1 to 5 times to 46% of the clinicians. The main cause was the excessive use of the instrument, it was stated by 61% of total clinicians and by 46.9% of Endodontists. Lack of technical and scientifical knowledge was pointed to be the cause of fracture by 39.5%. 74% felt that is necessary a continued learning program about accidents and complications in Endodontics and 62.5% did not know any method to remove a fracture instrument. 27% suggested a greater theoretical study about endodontic treatment accident focusing legal aspects. Concerning previous patient awareness of risks related to Endodontic treatment, 59% uses verbal explanation, 35.5% did not explain and only 20.5% uses written material. It was concluded through data analysis that clinicians are not well prepared to deal with Endodontic instrument fracture about therapeutic and techniques used to remove the fractured instruments. Considering that the excessive use of the instrument was the first cause of its fracture showed by the responding, the clinicians have to establish how many times the same instruments can be used. Both endodontists and clinicians behave in a more proper ethical way in professional/patient relationship than among professionals, and among the clinicians, they be have in a proper ethical way than the Endodontics. It is also conclude that the majority of clinicians are not well prepared in terms of records and are vulnerable when the Consumer¿s Code is applying in the Litigations. Thus, the clinicians should be prepared by malpractice claims doing a complete dental record / Mestrado / Mestre em Odontologia Legal e Deontologia
|
Page generated in 0.056 seconds