Spelling suggestions: "subject:"fratura""
201 |
Influ?ncia do design de restaura??es endocrown em CAD/CAM na carga m?xima de carregamento em molares tratados endodonticamenteModena, Cl?udia Freitas de Moura 20 January 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-04-06T13:03:53Z
No. of bitstreams: 1
DIS_CLAUDIA_FREITAS_DE_MOURA_MODENA_PARCIAL.pdf: 263042 bytes, checksum: d6f27d71d4ced5aa30be4d390438fe16 (MD5) / Made available in DSpace on 2016-04-06T13:03:53Z (GMT). No. of bitstreams: 1
DIS_CLAUDIA_FREITAS_DE_MOURA_MODENA_PARCIAL.pdf: 263042 bytes, checksum: d6f27d71d4ced5aa30be4d390438fe16 (MD5)
Previous issue date: 2016-01-20 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Objectives: To evaluate in vitro the influence of different cavity design preparations for endocrown restorations on the fracture resistance of endodontically treated molars. Materials and methods: Fifty extracted healthy third molars were divided randomly into 5 groups (n= 10 per group): H= healthy, F1= 1 ferrule, F2= 2 ferrules (buccal and palatal), FT= total ferrule and NF= flat plateau. The teeth were submitted to root canal treatment after which the cavity preparations were made. The crowns of endocrown, in Lava Ultimate, were manufactured with the CAD-CAM CEREC/INLAB system and cemented with Single Bond Universal and Rely X Ultimate. The resistance to fracture testing was made in a universal testing machine with a speed of 1mm/min. The pattern of failure was then evaluated, taking into consideration only the presence or absence of fracture in the pulp floor. Results: (Means followed by the same letter do not differ statistically for ANOVA and Tukey): H:3970N ab; F1:3170N ab; F2: 3786N ab; TF: 2894N b; NF:4416N a. The most prevalent pattern of failure was the type recoverable in all groups. Conclusions: The type of cavity preparation for endocrown restoration may influence the fracture resistance of endodontically treated molars. The type of ferrule may determine the greater resistance to loading. The pattern of failure was predominantly recoverable. / Objetivos: avaliar in vitro a influ?ncia de diferentes designs de preparos cavit?rios para restaura??es endocrown, na resist?ncia m?xima ao carregamento de molares endodonticamente tratados. Materiais e m?todos: Cinquenta terceiros molares h?gidos e extra?dos foram divididos aleatoriamente em 5 grupos (n= 10 por grupo), H= h?gido, F1= 1 f?rula, F2 = 2 f?rulas VL(vestibular e lingual), FT= f?rula total e SF= plat? reto. Os dentes foram submetidos ? endodontia e, ap?s, realizados os preparos cavit?rios. As coroas de endocrown, em Lava Ultimate, foram confeccionadas atrav?s do sistema CAD-CAM CEREC/INLAB e cimentadas com Single Bond Universal e Rely X Ultimate. O ensaio de resist?ncia ? fratura foi realizado em uma m?quina de ensaios universal com velocidade de 1mm/min at? o rompimento do corpo de prova. Ap?s, foi avaliado o padr?o de falha o qual levou em considera??o apenas a presen?a ou n?o de fratura do assoalho pulpar. Resultados: (m?dias seguidas de mesma letra n?o apresentam diferen?a estat?stica para ANOVA e Tukey): H:3970N AB; F1:3170N AB; F2: 3786N AB; FT 2894N B; SF:4416N A. O padr?o de falha predominante foi do tipo fratura da restaura??o em todos os grupos. Conclus?es: o tipo de preparo cavit?rio para restaura??es endocrown pode influenciar na resist?ncia ? fratura de molares tratados endodonticamente. O tipo de f?rula utilizada pode determinar maior resist?ncia ao carregamento. O padr?o de falha foi predominantemente recuper?vel.
|
202 |
An?lise por elementos finitos de nova proposta de dispositivo para redu??o e fixa??o das fraturas de c?ndilo mandibularConci, Ricardo Augusto 09 March 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-05-13T11:41:26Z
No. of bitstreams: 1
TES_RICARDO_AUGUSTO_CONCI_COMPLETO.pdf: 49140416 bytes, checksum: d2aa3ccb467a7e2955c07d181b6496d8 (MD5) / Made available in DSpace on 2016-05-13T11:41:26Z (GMT). No. of bitstreams: 1
TES_RICARDO_AUGUSTO_CONCI_COMPLETO.pdf: 49140416 bytes, checksum: d2aa3ccb467a7e2955c07d181b6496d8 (MD5)
Previous issue date: 2016-03-09 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / The large incidence and the controversies related to the diagnose, forms of treatment, surgical accesses and osteosynthesis material types, determine that condylar fractures have a featured place among facial fractures. It is possible to perform a surgical or non surgical treatment depending on the endless situations and clinical indications. After choosing the surgical access, one should obtain an adequate reduction of the fractures and an effective internal fixation, respecting the anatomic characteristics of the condylar region, in order to obtain a satisfying funcional result. Plates configurations, isolated or not, with different shapes and sizes, can be used for a surgical solution to the condylar fractures. Aiming an enhancement of the advantages and decreasing of the disadvantages, regarding the fixation techniques, the screw Neck Screw was developed, with the purpose of creating the stabilization required to achieve a correct fixation through a dynamic compression system, increasing the contact between the fractured bone stubs, as well as serving as an ally when reducing the fractures. The present paper has as objective to evaluate the fixation and the stability of the jaw condyle fractures, and compare four fixation techniques: the first configuration presents a 2.0 mm plate, with four holes in it, the second one has two plates, one of 2.0 mm and the other with 1.5 mm, both with four holes in it and screws 6.0 mm long, the third fixation system has the Neck Screw and a ?L? shaped plate, with four holes, 2.0 mm wide, overlapped between them, and the last one has the Neck Screw and the ?L? shaped plate forming a single device, united through a solder. The results demonstrate a better stability when using two plates, regarding the dislocation of the fractures, synthesis materials deformation, minimal and maximal tension values. The results with the Neck Screw are satisfying, much as the ones found when using a mini plate, being, therefore, an alternative to the reduction and fixation of condylar fractures, if correctly indicated and with an adequate surgical sequence and technique. / A grande incid?ncia e as controv?rsias relacionadas ao diagn?stico, formas de tratamento, acessos cir?rgicos e tipos de materiais de osteoss?ntese, fazem com que as fraturas condilares tenham papel de destaque dentre as fraturas faciais. Pode-se realizar tratamento cir?rgico ou n?o-cir?rgico, dependendo de in?meras situa??es e indica??es cl?nicas. Quando escolhido o acesso cir?rgico, deve-se conseguir redu??o adequada das fraturas e fixa??o interna eficiente, respeitando as caracter?sticas anat?micas da regi?o condilar, para obten??o de um resultado funcional satisfat?rio. Configura??es de placas, isoladas ou n?o, com formatos e tamanhos diversos, podem ser utilizadas para a resolu??o cir?rgica das fraturas condilares. Visando aprimorar as vantagens e minimizar as desvantagens das t?cnicas de fixa??o, foi desenvolvido o parafuso Neck Screw, objetivando a estabilidade necess?ria para a correta fixa??o por meio de um sistema de compress?o din?mica, aumentando o contato entre os cotos ?sseos fraturados, al?m de servir como aliado no momento da redu??o das fraturas. O presente trabalho tem como objetivo avaliar a fixa??o e a estabilidade das fraturas de c?ndilo mandibular e comparar quatro t?cnicas de fixa??o, sendo que a primeira configura??o apresenta uma placa de 2.0 mm, com 4 furos, com parafusos de 6 mm de comprimento, a segunda configura??o apresenta duas placas, sendo uma de 2.0 mm e outra de 1.5 mm, ambas com 4 furos, com parafusos de 6 mm de comprimento, o terceiro sistema de fixa??o com o parafuso Neck Screw e uma placa em ?L? de 4 furos de 2.0 mm sobreposta, al?m do ?ltimo grupo, onde o parafuso Neck Screw e a placa em ?L? formam um dispositivo ?nico, atrav?s de jun??o por ponto de solda. Os resultados demonstram uma melhor estabilidade quando do uso de duas placas, no que diz respeito ao deslocamento das fraturas, deforma??o dos materiais de s?ntese e valores de tens?es m?nimas e m?ximas. Os resultados com o parafuso Neck Screw s?o satisfat?rios, semelhantes aos encontrados quando da utiliza??o de uma miniplaca, sendo, portanto, uma alternativa para redu??o e fixa??o das fraturas condilares, desde que corretamente indicado e com sequ?ncia e t?cnica cir?rgica adequadas.
|
203 |
Estudo retrospectivo da preval?ncia de fraturas faciais no planalto serrano catarinensePaes, Jefferson Viapiana 06 March 2009 (has links)
Made available in DSpace on 2015-04-14T13:29:33Z (GMT). No. of bitstreams: 1
421639.pdf: 1440634 bytes, checksum: 89119d79663fc5ed44cc53e144c3c191 (MD5)
Previous issue date: 2009-03-06 / O presente estudo teve por objetivo realizar um levantamento epidemiol?gico das fraturas faciais ocorridas em pacientes admitidos no Servi?o de Cirurgia e Traumatologia Bucomaxilofacial do Hospital Nossa Senhora dos Prazeres (Lages, SC, Brasil), no per?odo de setembro de 2003 ? agosto de 2008. Dentre os fatores analisados, destaca-se o etiol?gico, a regi?o fraturada do esqueleto facial, em rela??o ao g?nero, ? idade e ? proced?ncia. Durante o per?odo estudado, 492 pacientes foram admitidos com traumatismos bucomaxilofaciais, sendo identificadas 988 fraturas faciais; as ocorridas no osso mandibular foram as mais freq?entes, seguidas das fraturas no complexo zigom?tico. Os pacientes do g?nero masculino sofreram, no m?nimo, quatro vezes mais traumatismos de face, que os pacientes do g?nero feminino. A faixa et?ria mais atingida foi dos 21 aos 30 anos de idade, seguidos do grupo dos 31 aos 40 anos de idade. Considerando os agentes etiol?gicos, os que mais ocasionaram fraturas faciais, foram acidentes automobil?sticos, seguidos de agress?es f?sicas e quedas de bicicleta. Dentro das condi??es do presente estudo, ? poss?vel concluir que esta pesquisa fornece dados para uma melhor elucida??o dos principais agentes etiol?gicos de fraturas faciais e quais s?o os ossos mais acometidos na popula??o estudada, sendo de fundamental import?ncia para o planejamento a organiza??o e a melhoria do atendimento desses pacientes, podendo, assim, servir como dados de compara??o de servi?os de atendimento e o impacto, destes, nas atividades hospitalares. Avalia??es peri?dicas da epidemiologia dos traumatismos faciais permitem uma an?lise detalhada destas les?es, apoiando na elei??o de prioridades cl?nicas e de pesquisa para um melhor atendimento e preven??o de traumatismos futuros.
|
204 |
Efeitos da expans?o r?pida da maxila na posi??o do c?ndilo em tomografias computadorizadas - Cone BeamSqueff, Karine 30 June 2011 (has links)
Made available in DSpace on 2015-04-14T13:30:01Z (GMT). No. of bitstreams: 1
433584.pdf: 1265477 bytes, checksum: 96aee194604ab9b5877f91c360a53158 (MD5)
Previous issue date: 2011-06-30 / Introdu??o: O conhecimento da posi??o do c?ndilo em rela??o ? cavidade articular podeservir como base para estudos relacionados ?s desordens t?mporo maxilo-mandibulares(DTMs). Durante a expans?o r?pida da maxila (ERM), uma intensa atividade sutural ocorreentre os ossos com os quais a maxila se articula, incluindo a articula??o temporomandibular(ATM). Com a Tomografia computadorizada Cone Beam (TCCB) ? poss?vel visualizar aposi??o do c?ndilo na cavidade articular no sentido coronal, sagital e axial, o que antes,devido a quest?es anat?micas, sempre foi de dif?cil interpreta??o.. Objetivos: Propor umametodologia de posicionamento do cr?nio para avalia??o do c?ndilo e realizar a avalia??o daposi??o condilar em rela??o ? cavidade articular em TCCB, antes, imediatamente ap?s e seismeses depois da ERM, no sentido axial e sagital. Metodologia: Neste estudo retrospectivo,com pacientes entre 7 e 14 anos, foram realizadas medidas inter e intraexaminadores em 10TCCB da posi??o condilar em rela??o ? cavidade articular, padronizando a posi??o dacabe?a e c?ndilo atrav?s de estruturas anat?micas est?veis e de f?cil identifica??o. Os dadosforam analisados atrav?s de medidas descritivas (m?dia e desvio-padr?o). Ap?s, foramavaliados 34 pacientes, 11 do sexo masculino e 23 do sexo feminino, com defici?nciatransversa da maxila. Mediu-se o tamanho do c?ndilo (TCo), espa?o superior (ES), espa?oposterior (EP), espa?o anterior (EA) entre a cavidade articular e o c?ndilo e a angula??o doc?ndilo (AC). A partir desses dados avaliou-se a posi??o do c?ndilo em rela??o ? cavidadearticular anterior, centralizado ou posterior. Essas variantes foram medidas nos grupos come sem mordida cruzada. Resultados: Os resultados estat?sticos indicaram confiabilidadeintraexaminador e interexaminadores para a metodologia proposta. Nos pacientes semmordida cruzada, n?o foi observado um padr?o em rela??o ? posi??o condilar inicial(anterior, centralizada ou posterior). Houve uma modifica??o transit?ria, imediatamente ap?sa ERM, com aumento do ES e EA em rela??o ? cavidade articular que, em seis meses ap?s aERM, voltaram ? posi??o inicial. No grupo com mordida cruzada, tamb?m n?o houve umpadr?o em rela??o ? posi??o condilar inicial e houve mudan?as transit?rias imediatamenteap?s a ERM. Nos pacientes com mordida cruzada no lado da mordida cruzada, seis mesesap?s a ERM houve um retorno do c?ndilo ? sua posi??o inicial. No lado oposto, houve umaumento do EA que ocorreu imediatamente ap?s a ERM, com leve redu??o em seis meses, mas ainda aumentado em rela??o ? posi??o inicial. O TCo e a AC n?o apresentaramdiferen?as significativas nos grupos e tempos avaliados. N?o houve diferen?a estat?sticaentre os g?neros para a posi??o condilar antes, imediatamente e seis meses ap?s a ERM. Conclus?es: Foi encontrada alta confiabilidade das medidas avaliadas, sendo a metodologiademonstrada no estudo precisa para realiza??o de avalia??es da posi??o do c?ndilo emrela??o ? cavidade articular. N?o houve um padr?o definido na mudan?a da posi??o doc?ndilo. Houve uma modifica??o transit?ria, imediatamente ap?s a ERM, com aumento doES e EA em rela??o ? cavidade articular que, em seis meses ap?s a ERM, voltaram ? posi??oinicial.
|
205 |
Estudo comparativo entre a fixa??o interna r?gida com parafuso compressivo tipo neck screw e microplacas com microparafusos nas fraturas do complexo zigom?ticoOmizzolo, Guilherme 29 June 2012 (has links)
Made available in DSpace on 2015-04-14T13:30:15Z (GMT). No. of bitstreams: 1
440591.pdf: 3736403 bytes, checksum: 8a5e110d9859d4c6d6a19122ed5e0f65 (MD5)
Previous issue date: 2012-06-29 / The tetraploid fractures from the zygomatic complex need accuracy in the correction and an efficient internal fixation for obtaining a good final result. Aiming at improving the advantages and minimizing the disadvantages of the rigid internal techniques, the screw "Neck Screw" was developed. The necessary stability for the correct fixation comes from a dynamic compression sistem increasing the contact between the stumps fractured. This assignment has the objectives to evaluate: the fixation and the stability of the dysjunction-fractures of the zygomatic complex provided by the screw "Neck Screw", applied in the region of the frontozygomatic suture, and to compare with a technique already devoted of micro-plaques and micro-screws applied in the region of the frontozygomatic suture and edge of inferior orbit; the after-operative confort or the disconfort reported by the pacient; the medium medical-surgical time used. To evaluate the efficiency of the screw "Neck Screw", thirty pacients with tetraploid fractures of zygoma had their computerized tomographies done on axial and coronale cuts for evidencing the fractures and for surgical planning. The pacients were subjected to the surgical procedure with osteosynthesis through the "Neck Screw" and the micro-plaque and micro-screw technique in the frontozygomatic region, having the surgical time properly noted. After 24 hours and 30 days, they were subjected to a new tomographic exam. The results gotten and measuremented were subjected to statistical tests of Mann Whitney, among the techniques used, and test T for the time. The importance of this research lies on the proposal of a technique for the reduction and fixation of the disjunction-fractures of the zygomatic complex minimally invasive in relation to the other techniques compared in the literature. The technique with the screw, "Neck Screw", guarantees stability of the fixation through the tomographic follow up. The analysis of the statistic about the measurements was revealed highly significant. The pacients' clinic follow up showed us absense of facial asymmetry, enophthalmos or diplopia. The operating time is significantly reduced and there is decrease of the disconfort reported by the pacients when palpating on the frontzygomatic region, thus the screw, "Neck screw", has an intra-osseous housing. / As fraturas tetrapoides do complexo zigom?tico necessitam de uma exatid?o na corre??o, al?m de eficiente fixa??o interna para se obter um bom resultado final. Almejando aprimorar as vantagens e minimizar as desvantagens das t?cnicas de fixa??o interna r?gida, foi desenvolvido o parafuso neck screw. A estabilidade necess?ria para a correta fixa??o vem de um sistema de compress?o din?mica aumentando o contato entre os cotos fraturados. O presente trabalho teve como objetivos avaliar: a fixa??o e a estabilidade das fraturas do complexo zigom?tico tipo B proporcionadas pelo parafuso neck screw, aplicado na regi?o da sutura frontozigom?tica e comparando com uma t?cnica de microplacas e microparafusos, na regi?o da sutura frontozigom?tica e no bordo da regi?o orbit?ria inferior; o conforto ou desconforto p?s-operat?rios ? palpa??o relatados pelo paciente e o tempo cir?rgico m?dio empregado. Para avaliar a efici?ncia do parafuso neck screw, trinta pacientes com fratura tetrapoide de zigoma tiveram realizadas tomografias computadorizadas em cortes axiais e coronais para evidencia??o das fraturas e planejamento cir?rgico; os pacientes foram submetidos ao procedimento cir?rgico, com osteoss?ntese atrav?s do parafuso neck screw e a t?cnica de microplaca e microparafuso na regi?o frontozigom?tica, com o tempo cir?rgico registrado; ap?s vinte e quatro horas e trinta dias foram submetidos a novo exame tomogr?fico. Os resultados coletados e mensurados foram submetidos a teste estat?stico de Mann Whitney entre as t?cnicas usadas e teste T para o tempo. O ponto principal desta pesquisa est? na proposi??o de uma t?cnica para a redu??o e fixa??o das fraturas-disjun??o do complexo zigom?tico minimamente invasivo em rela??o ?s outras t?cnicas comparadas na literatura. A t?cnica com o parafuso neck screw neste trabalho garante estabilidade da fixa??o pelo acompanhamento tomogr?fico. A an?lise da estat?stica sobre as mensura??es se demonstrou altamente significativa. O acompanhamento cl?nico dos pacientes nos apresentou aus?ncia de assimetria facial, enoftalmo, ou diplopia; o tempo operat?rio ? significativamente reduzido e com a observa??o da diminui??o do desconforto referido pelos pacientes diante da palpa??o na regi?o frontozigom?tica, pois o parafuso neck screw tem um alojamento intra?sseo.
|
206 |
Estudo comparativo das t?cnicas de fixa??o ?ssea em fraturas de c?ndilo mandibular atrav?s de an?lise por elementos finitosConci, Ricardo Augusto 24 February 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:31Z (GMT). No. of bitstreams: 1
456864.pdf: 1845700 bytes, checksum: a5c9dbfafcce1c6f9782ab16bd534d34 (MD5)
Previous issue date: 2014-02-24 / Mandibular condylar fractures are a theme of great importance within Oral and Maxillofacial Surgery due to their high incidence among facial fractures, and to numerous discussions regarding forms of treatment, surgical approaches, and the type of material used for fracture fixation. Treatment can be either surgical or nonsurgical, and depends upon certain situations and directions. When the choice is for surgical treatment proper fracture reduction and efficient internal fixation must be pursued to achieve good final results. Numerous plate configurations, whether or not isolated, with various shapes and sizes, are used for the surgical resolution of condylar fractures. In order to enhance the advantages and minimize the disadvantages of fixation techniques, the Neck Screw was developed, aiming at the necessary stability for proper fixation through a dynamic compression system that could increase the contact between the fractured stumps, and, at the same time, assist at the time of fracture reduction. The purpose of this study was to assess the fixation and stability of mandibular condylar fractures, and to compare three fixation techniques, in that the first configuration had a 2.0 mm plate with 4 holes, and with 6-mm-long screws, the second configuration had two plates ─ one of 1.5 mm and the other of 2mm ─-both with 4 holes, and with 6-mm-long screws, and the last had a Neck Screw. The results showed improved stability when using two plates, in regard to displacement of the fractures, deformation of the synthesis materials, and minimum and maximum tension values. The results with the Neck Screw were satisfactory, similar to those found when using a Mini-Plate, and it is thus an alternative for the reduction and fixation of condylar fractures, provided it is correctly prescribed, and follows an appropriate surgical sequence and technique / As fraturas de c?ndilo mandibular representam um tema de grande import?ncia dentro da Cirurgia e Traumatologia Bucomaxilofacial, pela grande incid?ncia dentre as fraturas faciais, al?m das in?meras discuss?es no que diz respeito ?s formas de tratamento, acessos cir?rgicos e o tipo de material que vai ser utilizado para fixa??o das fraturas. O tratamento divide-se em cir?rgico e n?o-cir?rgico, e depende de algumas situa??es e indica??es. Quando o tratamento cir?rgico ? a escolha, deve-se buscar uma adequada redu??o das fraturas, al?m de eficiente fixa??o interna para se obter um bom resultado final. In?meras configura??es de placas, isoladas ou n?o, com formatos e tamanhos variados, s?o utilizadas para a resolu??o cir?rgica das fraturas condilares. Almejando aprimorar as vantagens e minimizar as desvantagens das t?cnicas de fixa??o, foi desenvolvido o parafuso Neck Screw, visando a estabilidade necess?ria para a correta fixa??o atrav?s de um sistema de compress?o din?mica, aumentando o contato entre os cotos fraturados, al?m de servir como aliado no momento da redu??o das fraturas. O presente trabalho tem como objetivo avaliar a fixa??o e a estabilidade das fraturas de c?ndilo mandibular e comparar tr?s t?cnicas de fixa??o, sendo que a primeira configura??o apresenta uma placa de 2.0 mm, com 4 furos, com parafusos de 6 mm de comprimento, a segunda configura??o apresenta duas placas, sendo uma de 1.5 mm e outra de 2.0 mm, ambas com 4 furos, com parafusos de 6 mm de comprimento e a ?ltima, apresenta o parafuso Neck Screw. Os resultados demonstram uma melhor estabilidade quando do uso de duas placas, no que diz respeito ao deslocamento das fraturas, deforma??o dos materiais de s?ntese e valores de tens?es m?nimas e m?ximas. de tens?es m?nimas e m?ximas.Os resultados com o parafuso Neck Screw s?o satisfat?rios, semelhantes aos encontrados quando da utiliza??o de uma miniplaca, sendo, portanto, uma alternativa para redu??o e fixa??o das fraturas condilares, desde que corretamente indicado e com sequ?ncia e t?cnica cir?rgica adequadas
|
207 |
Traumatologia bucomaxilofacial em telessa?de : uma proposta metodol?gicaBerthold, Roger Corr?a de Barros 24 February 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:33Z (GMT). No. of bitstreams: 1
458478.pdf: 697767 bytes, checksum: fd7d67401e87529882fe06fac187d9a4 (MD5)
Previous issue date: 2014-02-24 / Introduction: The earliest objective of Telemedicine was to assist in the delivery of health care to persons geographically remote from physicians or a medical center. However, with the recent advances in information technology Telemedicine gained a broader reach. The most important advance was the stablishment of mHealth. Mobile phones, particularly smartphones (sophisticated internet-accessible cellular phones) and other mobile computing devices (tablets), are becoming increasingly ubiquitous, which enhances the potential to assess and improve health. The recent proliferation of wireless and mobile technologies provided the opportunity to obtain and exchange information in a fast and efficient way. However these devices must be validated for Telemedicine use. Objective: to evaluate the level of agreement between three oral and maxillofacial surgeons in the diagnosis of midface fractures from photographs of occiptomental radiographs by three mobile devices: Camera, tablet and smartphone and to evaluate each one of the oral and maxillofacial surgeons among the three mobile devices. Methods: twenty occiptomental radiographs were selected and photographed in a lightbox by a digital c?mera, a tablet and a smartphone. The sixty imagens were transfered to a notebook. Three oral and maxillofacial surgeons were asked for the presence and location of midface fractures. Results: There were no statistical diferences, in the level of 5%, among the three surgeons, for fracture identification and localization. There were no statistical diferences for each oral and maxillofacial surgeon among the three mobile devices for fracture identification and localization. Conclusion: Based upon the methods used in this study mobile devices can be used for diagnosis of midface fractures. / Introdu??o: O primeiro objetivo da Telemedicina era auxiliar na presta??o de cuidados de sa?de a pessoas geograficamente distantes de profissionais da ?rea m?dica ou de um centro de refer?ncia em sa?de. No entanto, com os recentes avan?os na Tecnologia da Informa??o a Telemedicina ganhou um alcance mais amplo. O avan?o mais importante foi a implementa??o da sa?de m?vel. Os telefones celulares, especialmente smartphones sofisticados, com acesso ? internet e outros dispositivos de computa??o m?vel, como tablets, est?o se tornando cada vez mais onipresentes, o que aumenta o potencial para avaliar e melhorar a sa?de. Objetivo: avaliar a concord?ncia entre tr?s avaliadores (cirurgi?es buco-maxilo-faciais) no diagn?stico de fraturas do ter?o m?dio da face a partir de imagens radiogr?ficas (Waters) fotografadas por tr?s dispositivos m?veis (c?mera fotogr?fica, Tablet e smartphone) e avaliar a concord?ncia de cada um dos tr?s avaliadores, utilizando os tr?s dispositivos no diagn?stico de fraturas do ter?o m?dio da face. Metodologia: Foram selecionadas 20 radiografias extra-orais, p?stero-anteriores, Naso-mento (Waters), colocadas em um negatosc?pio e fotografadas com tr?s dispositivos diferentes: uma c?mera fotogr?fica, um tablet e um smartphone. As 60 imagens foram transferidas para um notebook em uma ordem aleat?ria e apresentada para tr?s cirurgi?es buco-maxilo-faciais. Os avaliadores foram questionados sobre a presen?a e a localiza??o de fraturas nas imagens. Resultados: N?o houve diferen?as estat?sticas significativas, ao n?vel de 5% entre os tr?s avaliadores, tanto para observa??o de fratura quanto para a localiza??o dessa. Al?m disso, n?o houve diferen?a estatisticamente significativa para cada um dos tr?s avaliadores, ao n?vel de 5%, entre os tr?s equipamentos, tanto para observa??o de fratura quanto para a localiza??o dessa. Conclus?o: Baseado na metodologia aplicada nesse estudo os dispositivos m?veis podem ser utilizados no diagn?stico de fraturas do ter?o m?dio da face.
|
208 |
Avalia??o da resist?ncia ? fratura de coroas CAD-CAM sobre pilares s?lidosStona, Deborah 25 February 2014 (has links)
Made available in DSpace on 2015-04-14T13:30:35Z (GMT). No. of bitstreams: 1
459296.pdf: 283193 bytes, checksum: 3d97b7d2dd51eab591a5bbae03076040 (MD5)
Previous issue date: 2014-02-25 / The aim of the study was to evaluate the fracture resistance of ceramic crowns using Cerec CAD-CAM system on solid pillars. Sixty replica synocta implant and RN solid abutment were embedded in acrylic resin, being randomly assigned (n=20 per group). Three types of ceramics were used: Mark II (feldspar), IPS Empress CAD (leucite) and IPS e.max CAD (lithium disilicate). The crowns were fabricated by CAD-CAM system using the Cerec software version 4.1. After receiving glaze and were cemented with RelyX U200 cement under load of 1 Kg Half of the specimens of each ceramic was subjected to endurance EMIC DL-2000 test fracture in a universal testing machine with a speed of 1 mm / minute and the other half after 1,000,000 cycles of mechanical stress with a load of 100 N. According to two-way ANOVA, the interaction between the material and mechanical cycling was significant (p = 0.0001). According to Tukey test (α = 5%) the fracture toughness without mechanical cycling and mechanical cycling, respectively, of Mark II (405N/454N) was statistically lower than ceramic IPS Empress CAD (1169N/1240N) and IPS e.max CAD (1378N/1025N) (p < 0.05). The ceramic IPS Empress CAD and IPS e.max CAD not differ statistically (p > 0.05). There was no statistical difference in the resistance to cyclic loading with and without fracture to the Mark II and IPS Empress CAD (p > 0.05, Student's t test) ceramics. For ceramic IPS e.max CAD, the fracture resistance without mechanical cycling was statistically superior to that obtained with cycling (p < 0.05). The ceramic IPS Empress CAD and IPS e.max CAD showed higher fracture resistance compared to ceramic Mark II. The cyclic loading negatively influenced only IPS e.max CAD. / O objetivo do estudo foi avaliar a resist?ncia ? fratura de coroas cer?micas utilizando o sistema CAD-CAM Cerec sobre pilares s?lidos. Sessenta r?plicas de implante synocta RN e pilar s?lido foram inclu?dos em resina acr?lica autopolimeriz?vel, sendo divididas aleatoriamente (n=20 por grupo). Tr?s tipos de cer?micas foram utilizadas: Mark II (feldsp?tica), IPS Empress CAD (leucita) e IPS e.max CAD (dissilicato de l?tio). As coroas foram confeccionadas atrav?s do sistema CAD-CAM utilizando o software Cerec vers?o 4.1. Ap?s receberam glaze e foram cimentadas com RelyX U200 sob carga de cimenta??o de 1 Kg. Metade dos corpos de prova de cada cer?mica foi submetida ao teste de resist?ncia ? fratura em m?quina de ensaio universal EMIC-DL 2000 com velocidade de 1 mm/minuto e, a outra metade, ap?s 1.000.000 de ciclos de fadiga mec?nica com carga de 100 N. Segundo ANOVA de duas vias, a intera??o entre material e ciclagem mec?nica foi significativa (p=0,0001). De acordo com o teste de Tukey (α=5%) a resist?ncia ? fratura, sem ciclagem mec?nica e com ciclagem mec?nica respectivamente, da cer?mica Mark II (405N/454N) foi estatisticamente menor que as cer?micas IPS Empress CAD (1169N/1240N) e IPS e.max CAD (1378N/1025N) (p<0,05). As cer?micas IPS Empress CAD e IPS e.max CAD n?o diferiram estatisticamente entre si (p>0,05). N?o houve diferen?a estat?stica na resist?ncia ? fratura sem e com ciclagem mec?nica para as cer?micas Mark II e IPS Empress CAD (p>0,05, teste t-student). Para a cer?mica IPS e.max CAD, a resist?ncia ? fratura sem ciclagem mec?nica foi estatisticamente superior ? obtida com ciclagem (p<0,05). As cer?micas IPS Empress CAD e IPS e.max CAD apresentaram maior resist?ncia ? fratura quando comparadas com a cer?mica Mark II. A ciclagem mec?nica influenciou negativamente apenas a cer?mica IPS e.max CAD.
|
209 |
Fraturas de rádio e ulna em cães no período de janeiro de 2001 a dezembro de 2011 /Meirelles, Adriana Érica Wilkes Burton. January 2013 (has links)
Orientador: Júlio Carlos Canola / Banca: Andrigo Barboza de Nardi / Banca: Paola Castro Moraes / Resumo: Fraturas são afecções comuns no atendimento de rotina de pequenos animais em Medicina Veterinária. A radiografia, parte do exame ortopédico, é essencial para a confirmação do diagnóstico, classificação da fratura e para auxiliar na escolha e no acompanhamento do tratamento. As fraturas de rádio e ulna são as terceiras mais frequentes em cães. Estudos retrospectivos de fraturas de rádio e ulna são escassos e com este trabalho objetivou-se reavaliar os casos de fraturas destes ossos em cães atendidos no Hospital Veterinário da FCAV/UNESP, Jaboticabal, entre o período de Janeiro de 2001 a Dezembro de 2011, para estabelecer a ocorrência dos tipos de fraturas, dos dados do paciente, os métodos de correção utilizados e as complicações mais comuns decorrentes da osteossíntese. Um total de 310 fraturas de rádio e ulna foram avaliadas. As mais comuns foram completas, transversas, fechadas e localizadas em diáfise distal de rádio e ulna. Cães de raças pequenas, pesando até 5 kg, e das raças pinscher, poodle e terrier brasileiro foram os mais acometidos. A faixa etária mais frequente foi a de cães adultos, acima de 12 meses. Quedas ou pulos e atropelamentos foram as principais causas de fraturas. O uso de fixador externo resultou no maior número de casos de união retardada. Não houve diferença significativa para os casos de malunião e não união ossea entre os diferentes tratamentos realizados. A complicação mais comum foi osteólise nos pacientes tratados com placa e fixador externo e osteopenia e degeneração iatrogênica do carpo nos tratados com pino intramedular. Espera-se que este estudo possa servir como referência para estudo avançados com a busca de novos implantes e técnicas em ortopedia veterinária e para a seleção de pacientes para estudos prospectivos / Abstract: Fractures are commonly seen in veterinary medicine practice. Radiography is part of the orthopedic exam and is essential for confirmation of diagnosis, classification of fracture and assists in choosing and monitoring treatment. Radius and ulna fractures are the third most frequent in dogs. Retrospective studies regarding this subject are scarce. The aim of this study was to evaluate cases of radius and ulna fractures in dogs treated at the Veterinary Hospital at FCAV/UNESP, Jaboticabal, from January 2001 to December 2011, to establish the frequency of fracture types, patient data, repair methods and most common complications following osteosynthesis. A total of 310 radius and ulna fractures were evaluated. The most common types of fracture were complete, transverse, closed and located in the distal shaft. Small dogs weighing up to 5 kg and pinscher, poodle and brazilian terrier breeds were the most affected. Adult dogs, over 12 months old, were the most frequent age group. Falls or jumps and motor vehicle trauma were the main causes of fractures. External fixator yielded the highest number of delayed union. There was no differences between malunion and nonunion between the different treatments. The most common complication was osteolises in dogs treated with bone plate and external fixator, and osteopenia with iatrogenic carpal degeneration in those treated with intramedullary pin. We hope this study can serve as reference for advanced research in Veterinary Orthopedics, as in discoveries of new implants and techniques, and for the selection of patients in prospective studies / Mestre
|
210 |
Osteossíntese minimamente invasiva com placa bloqueada nas fraturas de tíbia em cães /Rosa-Ballaben, Nátalie Massaro. January 2014 (has links)
Orientador: Bruno Watanabe Minto / Banca: Cláudia Valéria Seullner Brandão / Banca: Paola Castro Moraes / Resumo: Avanços na compreensão da biologia óssea e das complicações das fraturas têm levado a modificações na abordagem da fixação interna das mesmas, sendo a osteossíntese minimamente invasiva com placa (MIPO) uma das mais recentes evoluções para o manejo biológico das fraturas. O objetivo do presente estudo foi avaliar o uso de placas bloqueadas aplicadas de forma minimante invasiva em fraturas de tíbia de cães. Foram utilizados 10 cães apresentando fraturas de tíbia, de idades e raças variadas. Os animais foram avaliados quanto a deambulação, intensidade do edema, exames radiográficos, e densitometria óptica nos períodos 0, 15, 30, 60, 90 e 120 dias de pós-operatório. Após 15 dias de pós-operatório 80% dos cães já utilizavam o membro ao caminhar e apresentavam formação de edema leve a ausente no membro operado. Após 30 dias de pós-operatório 100% dos cães já apoiavam o membro ao caminhar e não apresentavam formação de edema no membro. Todos os pacientes apresentaram sinais radiográficos e densitométricos de início de consolidação óssea após 15 dias de pós-operatório. O tratamento de fraturas de tíbia por meio da MIPO é uma alternativa eficaz, resultando em utilização precoce do membro e união clínica efetiva, e pode ser realizada sem uso de intensificadores de imagem / Abstract: Advances in the comprehension of the bone healing and complications of the treatment of the fractures have been changed some concepts. Less invasive procedures have been advocated. A minimally invasive plate osteosynthesis (MIPO) is one of the best ways to avoid over tissue damage. The aim of this study was to evaluate the use of MIPO in tibial fractures in dogs. Ten dogs presenting a tibial fracture were used. Deambulation, swelling intensity and radiographic changes were evaluated preoperatively, just after the procedure and at 15, 30, 60, 90 e 120 days postoperatively. Six of 10 (60%) dogs were able to walk at 15 days postoperatively with slight swelling and mild lameness. Two of 10 (20%) presented normal walking at the same period. At 30 days postoperatively all dogs were able to walk normally. Six of them were not lame and 9 did not present swelling. Bone healing could be followed by radiographic evaluation. All dog presented initial radiographic signs of bone healing after 15 days postoperatively. Two of 10 showed clinical union at this time. In five of 10 (50%) clinical union could be observed after 60 days. The treatment of tibial fractures by MIPO is an effective alternative resulting in early and effective clinical union and can be performed without the use of image intensifiers / Mestre
|
Page generated in 0.0408 seconds