• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 257
  • 4
  • 1
  • Tagged with
  • 262
  • 111
  • 97
  • 88
  • 79
  • 49
  • 44
  • 38
  • 33
  • 31
  • 28
  • 26
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Relação entre apnéia do sono, isquemia miocárdica, variabilidade da freqüência cardíaca e arritmias em portadores de doença arterial coronária / Relation between sleep apnea, myocardial ischemia, heart rate variability and arrhythmias in patients with coronary artery disease

Araújo, Cristiana Marques de 02 May 2007 (has links)
Introdução: É comum a associação entre apnéia do sono e a doença arterial coronária (DAC), devido a fatores predisponentes comuns como sexo masculino e obesidade. Entretanto, ainda não existe uma definição objetiva da relação entre apnéia e DAC. Objetivo: Avaliar se os episódios de isquemia miocárdica, a variabilidade da freqüência cardíaca (VFC) e as arritmias cardíacas de portadores de DAC sofrem alteração na presença da apnéia do sono. Métodos: Cinqüenta e três pacientes portadores de DAC foram submetidos à monitorização eletrocardiográfica ambulatorial de 48 horas e ao estudo do sono na primeira noite da monitorização. Os pacientes foram divididos de acordo com o índice de apnéia e hipopnéia (IAH) em: grupo Controle (IAH<=15) e grupo Apnéia (IAH>15). Os grupos foram comparados quanto à isquemia miocárdica, VFC e arritmias cardíacas ocorridas no período da vigília e do sono. Uma subanálise apenas com pacientes portadores de apnéia grave (IAH>30 - grupo Ap-Grave) foi realizada e comparada ao grupo Controle. A análise estatística foi realizada utilizando-se o teste de Mann-Whitney, teste de Fisher e teste T de student. Resultados: Não foram observadas diferenças nas características clínicas básicas entre os grupos, exceto pelos níveis de pressão arterial mais elevada no grupo Ap-Grave (p<0,05). Nenhum dos pacientes despertou por angina noturna; 75% foram submetidos a cateterismo cardíaco, sem diferença quanto à gravidade da DAC e aos valores da fração de ejeção. Foi registrada isquemia em 39 (73,58%) pacientes, com carga isquêmica de 2892,26 minutos na vigília e 1186 no sono. Na vigília, foi menor a duração dos episódios isquêmicos no grupo Ap- Grave (p<0,05); no período do sono não houve diferença entre os grupos. Não houve diferença nas medidas da VFC e arritmias entre os grupos. Não foram registradas pausas >2 segundos, fibrilação ou flutter atrial, ou qualquer tipo de bloqueio atrioventricular. Conclusão: A apnéia do sono não apresentou relação direta com isquemia miocárdica, variabilidade da freqüência cardíaca e arritmias cardíacas em pacientes portadores de DAC. / Introduction: It is common to associate obstructive sleep apnea (OSA) with coronary artery disease (CAD) given the common predisposing factors; however, there are still controversies on the influence of OSA in the progression of CAD. Objective: To assess if OSA causes any changes in myocardial ischemia episodes, heart rate variability (HRV) and cardiac arrhythmias in patients with CAD. Methods: Fifty-three people with CAD were submitted to ambulatory electrocardiographic monitoring and to polysomnography) simultaneously and divided according to the apnea-hypopnea index (AHI) into two groups: Control (AHI<=15) and Apnea (AHI>15). A sub analysis including only people with severe apnea (AHI>30) was done and compared with the control group. Results: Differences in the basic clinical characteristics between the groups were not found, except for higher blood pressure levels in the Severe Apnea Group (p<0.05). None of the patients woke up because of nocturnal angina. The groups did not differ in relation to the extension of coronary artery disease and ejection fraction values. Myocardial ischemia was recorded in 39 (73.58%) patients. The total ischemic burden was 2892.26 minutes while awake and 1186 minutes while asleep; the groups did not differ during sleep. There was also no significant difference in HRV and arrhythmia measurements between the groups. Pauses >2 seconds, fibrillation or atrial flutter or any type of atrioventricular blocks were not registered. Conclusion: OSA did not present a direct relationship with myocardial ischemia, heart rate variability and arrhythmias in patients with CAD.
132

Polinômios de Szegö e análise de frequência

Milani, Fernando Feltrin [UNESP] 21 July 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-07-21Bitstream added on 2014-06-13T19:55:24Z : No. of bitstreams: 1 milani_ff_me_sjrp.pdf: 539043 bytes, checksum: b4613024414cd9fa758d64376a046176 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O objetivo deste trabalho é estudar os polinômios de Szegõ, que são ortogonais no círculo unitário, e suas relações com certas frações contínuas de Perron-Carathéodory e quadratura no círculo unitário, afim de resolver o problema de momento trigonométrico. Além disso, estudar a utilização dos polinômios de Szegõ na determinação das freqüências de um sinal trigonométrico em tempo discreto xN(m). Para isso, investigamos os polinômios de Szegõ gerados por uma medida N definida através do sinal trigonométrico xN(m), para m = 0, 1, 2,...N -1, e o comportamento dos zeros desses polinômios quando N_8. / The purpose here is to study the orthogonal polynomials on the unit circle, known as Szegõ polynomials, and the relations to Perron- Carathéodory continued fractions, and quadratures on the unit circle in order to solve the trigonometric moment problem. Another purpose is to study how the Szegõ polynomials can be used to determine the frequencies from a discrete time trigonometric signal xN(m). We investigate the Szegõ polynomials associated with a measure N defined by the trigonometric sinal xN(m), m = 0, 1, 2, ...N -1. We study the behaviour of zeros of these polynomials when N 8.
133

Estudo das propriedades dielétricas e ópticas na matriz cerâmica CaBi4Ti4O15 com adição de V2O5, Er2O3 e Yb2O3 / STUDY OF OPTICAL PROPERTIES AND THE DIELECTRIC CERAMIC MATRIX CaBi4Ti4O15 WITH ADDITION OF V2O5 / Er2O3 / Yb2O3

Campos Filho, Múcio Costa January 2015 (has links)
CAMPOS FILHO, Múcio Costa. Estudo das propriedades dielétricas e ópticas na matriz cerâmica CaBi4Ti4O15 com adição de V2O5, Er2O3 e Yb2O3. 2015. 169 f. Tese (Doutorado em Física) - Programa de Pós-Graduação em Física, Departamento de Física, Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2015. / Submitted by Edvander Pires (edvanderpires@gmail.com) on 2015-10-26T21:58:54Z No. of bitstreams: 1 2015_tese_mccamposfilho.pdf: 9304166 bytes, checksum: 0448bdd2063e3fc697dee9f5c6efb532 (MD5) / Approved for entry into archive by Edvander Pires(edvanderpires@gmail.com) on 2015-10-26T21:59:04Z (GMT) No. of bitstreams: 1 2015_tese_mccamposfilho.pdf: 9304166 bytes, checksum: 0448bdd2063e3fc697dee9f5c6efb532 (MD5) / Made available in DSpace on 2015-10-26T21:59:04Z (GMT). No. of bitstreams: 1 2015_tese_mccamposfilho.pdf: 9304166 bytes, checksum: 0448bdd2063e3fc697dee9f5c6efb532 (MD5) Previous issue date: 2015 / A strong demand for compressed materials, low cost and easy to manufacture are needed for various technological applications, in this sense many ceramics are candidates for its dielectric and optical properties .In this work, structural, dielectric and optical phase of the orthorhombic ferroelectric ceramic matrixCaBi4Ti4O15were investigated, one pseudo-perovskite bismuth layer structure (BLSFs) of space group A21am of the aurivillius family, prepared by the solid state method and sintered in low temperatures. Sample preparation for structural analysis and dielectric, had the addition of vanadium pentóxido (V2O5) to the phase CaBi4Ti4O15 calcined in ratios of 0.5, 1.0, 1.5, 2.0 and 5.0% by mass. To obtain optical properties of the ceramic matrix doped with rare earth ions erbiumIII (Er2O3) and III ytterbium oxide (Yb2O3). The study of the structure and composition of the samples was done by X-ray diffraction and confirmation was made by single stage rietveld refinement. The vibrational characteristics was obtained by Raman spectroscopy (RS). The morphology study off or analysis of grain and grain boundary, was performed by scanning electron microscopy. The dielectric characterization of radio frequency spectroscopy was performed in impedance which occurred two conductivity mechanisms for all samples, one at low frequency and the on the rat high frequency. Models of dielectric relaxation approach the Cole-Cole type model. Measures in the microwave range were obtained using the hakki-coleman method and monopole, which gave a temperature coefficient of resonant frequency (f) close to zero with the addition of V2O5. The dielectric permittivity measurements in radiofrequency and microwave, performe dat room temperature, had a high constant value (εr≈150) with the addition of 1%V2O5, and a value of relatively low loss tangent for family aurivillus (tan[δ]≈10-2) at 2 GHz. A numerical simulation was performed with each sample verifying approach with the experimental data. In rare earth doped samples was checked energy up-conversion phenomenon with the presence of intense bands samples of visible light emission in the green region and a less intense bands in thered region.The investigated material has potential for application in volatile memories, capacitive filters and optical components such as sensors, solar cells and LEDs. / Uma forte demanda por materiais mais compactados, de baixo custo e de fácil fabricação são necessários para diversas aplicações tecnológicas, neste sentido diversos materiais cerâmicos são candidatos por suas propriedades dielétricas e ópticas. Neste presente trabalho, foram investigadas as propriedades estruturais, dielétricas e ópticas da fase ortorrômbica da matriz cerâmica ferroelétrica CaBi4Ti4O15, uma pseudo-perosviskita de estrutura de camada de bismuto (BLSFs) do grupo espacial A21am da família aurivillius, preparada pelo método do estado sólido e sinterizada em baixas temperaturas. A preparação das amostras para análise estrutural e dielétrica, tiveram a adição de pentóxido de vanádio (V2O5) à fase CaBi4Ti4O15 calcinada, em proporções de 0.5, 1.0, 1.5, 2.0 e 5.0 % em massa. Para obtenção das propriedades ópticas, a matriz cerâmica pura foi dopada com os íons terras raras érbio III (Er2O3) e óxido de itérbio III (Yb2O3). O estudo da estrutura e composição das amostras foi feito através de difração de raios-X e a confirmação da fase única foi feita pelo Refinamento Rietveld. A caracterização vibracional foi obtida através da Espectroscopia Raman (SR). O estudo da morfologia, para análise de grão e contorno de grão, foi realizado através de Microscopia Eletrônica de Varredura. A caracterização dielétrica em radio freqüência foi realizada por Espectroscopia em Impedância a qual se verificou dois mecanismos de condutividade para todas as amostras analisadas, um em baixa freqüência e outro em alta freqüência. Os modelos de relaxação dielétrica se aproximam do modelo do tipo Cole-Cole. As medidas na faixa de microondas foram obtidas utilizando-se o método hakki-coleman e monopolo, chegou-se a um coeficiente de temperatura da frequência de ressonância (tAU f) próximo de zero com adição de V2O5. As medidas de permissividade dielétrica em radiofreqüência e microondas, realizadas em temperatura ambiente, tiveram um alto valor constante (εr ≈ 150) com a adição de 1% de V2O5, e um valor da tangente de perda relativamente baixa em relação à família de Aurivillus (tan[δ] ≈10-2 ) em 2 GHz.. Uma simulação numérica foi realizada com cada amostra verificando-se aproximação com os dados experimentais. Nas amostras dopadas com terras raras foi verificado o fenômeno de conversão ascendente de energia com a presença de bandas intensas amostras de emissão de luz visível na região do verde e de bandas de menor intensidade na região do vermelho. O Material investigado tem potencial para aplicação em memórias voláteis, filtros capacitivos e componentes ópticos, como sensores, células fotoelétricas e leds.
134

Projeto inversol - desenvolvimento de uma fonte ininterrupta de energia com possibilidade de uso em sistema fotovoltaico / Inversol – development of uninterruptible power suplly to be used in a photovoltaic system

Menezes, Lucas Maciel 06 July 2007 (has links)
MENEZES, L. M. Projeto inversol - desenvolvimento de uma fonte ininterrupta de energia com possibilidade de uso em sistema fotovoltaico. 216 f. 2007. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2007. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-03-17T13:37:00Z No. of bitstreams: 1 2007_dis_lcmenezes.pdf: 6838994 bytes, checksum: 0618e26e05217675047a41cff761ba75 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-03-18T17:43:54Z (GMT) No. of bitstreams: 1 2007_dis_lcmenezes.pdf: 6838994 bytes, checksum: 0618e26e05217675047a41cff761ba75 (MD5) / Made available in DSpace on 2016-03-18T17:43:54Z (GMT). No. of bitstreams: 1 2007_dis_lcmenezes.pdf: 6838994 bytes, checksum: 0618e26e05217675047a41cff761ba75 (MD5) Previous issue date: 2007-07-06 / The study of the development of initerruptible power supply to be used in a photovoltaic system has as motivation that the wide UPS production scale can reduce the cost of power electronics converters associated with a photovoltaic system. The project proposes a topology of an on-line UPS, with 220 Volts, 60 Hz input/output voltage, 715 VA power, 88% efficiency, High frequency isolation and Power factor correction. The Project consists on a rectifier, it is responsible for providing the input power factor correction and the high frequency isolation. An inverter, it supply the load with a output sinusoidal voltage and a high gain boost converter that increase the voltage from the battery pack up to the inverter. When the project is used in a photovoltaic system, it is only used the inverter and the high gain boost converter. / O estudo para o desenvolvimento de uma fonte ininterrupta de energia com possibilidade de uso em sistema fotovoltaico, tem como motivação que a larga escala da produção desse tipo de equipamento possa reduzir o custo dos conversores de eletrônica de potência associados a uma instalação fotovoltaica. O projeto proporem a união de topologias de conversores, resultando em uma UPS do tipo on-line com tensão de entrada e de saída de 220 Volts 60 Hz, potência total de 715VA, rendimento de 88%, isolada em alta freqüência e com correção do fator de potência na entrada. Sendo composta por um retificador na entrada com topologia de um conversor em ponte completa alimentado em corrente, esse conversor é responsável por prover a correção do fator de potência na entrada e da isolação galvânica em alta freqüência. Um inversor em ponte completa com filtro LC e modulação PWM unipolar, que é capaz de entregar uma tensão senoidal para a carga e um conversor boost de alto ganho que cumpre o papel de elevar a tensão de 24 Volts do banco de baterias para a tensão de 400 Volts do barramento de entrada do inversor. Cada conversor tem seu estudo teórico desenvolvido e ao final após as especificações e dimensionamentos são mostrados os resultados experimentais do protótipo do projeto. Quando o sistema for aproveitado em uma instalação fotovoltaica somente o inversor e o conversor boost de alto ganho são utilizados.
135

Oscilador controlado por tensão para operação programável de 3.7GHz a 8.8GHz para aplicações em múltiplas bandas de frequência / Analysis and design of a voltage-controlled oscillator for multiple frequency bands applications

Henes Neto, Egas January 2015 (has links)
Osciladores Controlados por Tensão (VCOs - Voltage-Controlled Oscillators) são circuitos de grande importância em sistemas de comunicação por radiofrequência atuais. Muitos trabalhos de pesquisa recentes têm focado no desenvolvimento de VCOs para aplicações em uma faixa muito grande de frequências (isto é, suportando amplo tunning range). O desenvolvimento de VCOs com uma ampla faixa de sintonia tem motivação na abertura de bandas de frequência, que até pouco tempo estavam licenciadas apenas para usos específicos, porém agora estão também abertas para a utilização de sistemas de rádios cognitivos. A ideia é que o rádio cognitivo tenha recursos para detectar se um canal (ou faixa de frequência) está sendo usado e, em caso de o canal não estar sendo usado, o rádio cognitivo deve se reconfigurar para operar nesse canal. Desse modo, os rádios cognitivos devem possuir um alto grau de reconfigurabilidade, de forma que possam operar em uma faixa muito ampla de frequências. Esse requisito exige o uso de de VCOs com um amplo tunning range. Este trabalho apresenta um projeto completo de um LC-VCO com uma larga faixa de frequência de operação (widedand). Um amplo tunning range foi obtido a partir do chaveamento (ou programação) do valor da capacitância total do tanque-LC do VCO, gerando assim várias sub-bandas de frequência. O ganho do VCO (KVCO) manteve-se com pequenas variações para todas as subbandas de frequência, com um valor médio de 88.6MHz, sendo 112MHz e 80MHz os valores máximo e mínimo, respectivamente. O ruído de fase variou de -118.4dBc/Hz a -107.4dBc/Hz para as portadores em 3.7GHz e 8.1GHz, respectivamente, enquanto que a potência dissipada do circuito LC-VCO variou de 1.8mW a 5.6mW para todo o tunning range. Para a figura de mérito power-frequency-tunning-normalized (FOMPFTN), os valores obtidos foram na faixa 3.1dB e 11.2dB, comparáveis com a maioria dos trabalhos publicados na área. / Voltage-Controlled Oscillators (VCOs) are very important circuits in current radio frequency communication systems. Much research has been focused recently on developing wideband VCOs in CMOS. The motivation on wideband VCOs is based on the opening of frequency bands, which until recently were licensed for specific uses, for use by cognitive radio systems. The idea is that cognitive radio must have the ability to detect whether a channel (or frequency band) is being used and if the channel is not being used, the cognitive radio must reconfigure itself to operate on that channel. Thus, cognitive radios should possess a high degree of reconfigurability, so that they can operate in a very wide frequency range. This requires the use of VCOs with a wide tunning range. This work presents a complete design of a LC-VCO with a wide operating frequency range (widedand). A wide tunning range has been obtained from the switching (or programming) the value of the total capacitance of the LC-tank of the VCO, thereby generating multiple frequency sub-bands. The VCO gain (KVCO) was maintained with small variations for all frequency sub-bands, with an average value of 88.6MHz, with 80MHz and 112MHz for the minimum and maximum values, respectively. The phase noise ranged from -118.4dBc/Hz to -107.4dBc/Hz for carriers at 3.7GHz and 8.1GHz, respectively, while the power dissipated in the LC-VCO circuit ranged from 1.8mW to 5.6mW for all tunning range. For the figure of merit power-frequency-tuning-normalized (FOMPFTN), the results were in the 3.1dB to 11.2dB range, comparable to most recently published works.
136

Testes modais utilizando martelo instrumentado em estruturas de baixas freqüências naturais / Modal test in low natural frequency structures by using as exciter an instrumented hammer

Lima, Michelline Nery Azevedo 30 November 2006 (has links)
Made available in DSpace on 2015-05-08T14:59:36Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1565570 bytes, checksum: 641bee91a3e1ec7240272fff8310ca82 (MD5) Previous issue date: 2006-11-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work it is discussed the improvement in the modal test for obtaining the Frequency Response Function (FRF) in low natural frequency structures by using as exciter an instrumented hammer. There are two conflicting needs in this kind of test: on the one hand, the low natural frequencies of the structure, which are usually associated with low damping, demand long acquisition time so that good resolution in the spectrum may exist. On the other hand, the sampling rate must be increased to correctly catch the short duration signal of the hammer. This leads to an elevated number of points in the signal to be acquired, and there may eventually be limitation on such number of points when using spectrum analyzers in the acquisition and obtaining of the FRFs. Thus, in this work, the selective decimation technique explored for the improvement of the test. The work includes the construction of a prototype with two degrees of freedom (S2GL) to serve as case study for the tests enabling the theoretical and experimental Frequency Response Functions (FRF) to be compared, as well as adjusting the parameters of the model. The MATLAB programming language was used for obtaining the FRFs. The efficiency of the improvement applied was verified through the frequency spectra, in which it was observed significant resemblance between the non-decimated FRF with the acquisition having a high number of points, and the decimated FRF with smaller number of points and selected so that it could preserve the correct detection of the hammer signal. / Neste trabalho discute-se o aprimoramento do teste modal para obtenção da Função Resposta em Freqüência (FRF) em estruturas de baixas freqüências naturais utilizando como excitador um martelo instrumentado. Há duas necessidades conflitantes neste tipo de teste: de um lado, as baixas freqüências naturais da estrutura, usualmente associadas com baixo amortecimento, requerem um tempo longo de aquisição para haver boa resolução no espectro. Por outro lado, a taxa de amostragem deve ser elevada para captar corretamente o sinal de curta duração do martelo. Isto leva a um número elevado de pontos no sinal a ser adquirido, havendo eventualmente limitação de tal número de pontos ao se utilizar analisadores de espectro na aquisição e obtenção das FRFs. Neste sentido, neste trabalho foi explorada a técnica de decimação seletiva para aprimoramento do teste. O trabalho inclui a construção de um protótipo com dois Graus de Liberdade (S2GL) para servir como objeto de estudo para os testes deste aprimoramento, permitindo assim, comparar as Funções Resposta em Freqüências (FRF) teóricas e experimentais, bem como ajustar os parâmetros do modelo. Utilizou-se da linguagem de programação MATLAB® para a obtenção das FRFs. A eficiência do aprimoramento empregado foi verificada através dos espectros de freqüência, onde observou-se uma significativa similaridade entre a FRF não decimada com a aquisição possuindo um número elevado de pontos e a FRF decimada com menor número de pontos e selecionada de modo a preservar a correta detecção do sinal do martelo.
137

Oscilador controlado por tensão para operação programável de 3.7GHz a 8.8GHz para aplicações em múltiplas bandas de frequência / Analysis and design of a voltage-controlled oscillator for multiple frequency bands applications

Henes Neto, Egas January 2015 (has links)
Osciladores Controlados por Tensão (VCOs - Voltage-Controlled Oscillators) são circuitos de grande importância em sistemas de comunicação por radiofrequência atuais. Muitos trabalhos de pesquisa recentes têm focado no desenvolvimento de VCOs para aplicações em uma faixa muito grande de frequências (isto é, suportando amplo tunning range). O desenvolvimento de VCOs com uma ampla faixa de sintonia tem motivação na abertura de bandas de frequência, que até pouco tempo estavam licenciadas apenas para usos específicos, porém agora estão também abertas para a utilização de sistemas de rádios cognitivos. A ideia é que o rádio cognitivo tenha recursos para detectar se um canal (ou faixa de frequência) está sendo usado e, em caso de o canal não estar sendo usado, o rádio cognitivo deve se reconfigurar para operar nesse canal. Desse modo, os rádios cognitivos devem possuir um alto grau de reconfigurabilidade, de forma que possam operar em uma faixa muito ampla de frequências. Esse requisito exige o uso de de VCOs com um amplo tunning range. Este trabalho apresenta um projeto completo de um LC-VCO com uma larga faixa de frequência de operação (widedand). Um amplo tunning range foi obtido a partir do chaveamento (ou programação) do valor da capacitância total do tanque-LC do VCO, gerando assim várias sub-bandas de frequência. O ganho do VCO (KVCO) manteve-se com pequenas variações para todas as subbandas de frequência, com um valor médio de 88.6MHz, sendo 112MHz e 80MHz os valores máximo e mínimo, respectivamente. O ruído de fase variou de -118.4dBc/Hz a -107.4dBc/Hz para as portadores em 3.7GHz e 8.1GHz, respectivamente, enquanto que a potência dissipada do circuito LC-VCO variou de 1.8mW a 5.6mW para todo o tunning range. Para a figura de mérito power-frequency-tunning-normalized (FOMPFTN), os valores obtidos foram na faixa 3.1dB e 11.2dB, comparáveis com a maioria dos trabalhos publicados na área. / Voltage-Controlled Oscillators (VCOs) are very important circuits in current radio frequency communication systems. Much research has been focused recently on developing wideband VCOs in CMOS. The motivation on wideband VCOs is based on the opening of frequency bands, which until recently were licensed for specific uses, for use by cognitive radio systems. The idea is that cognitive radio must have the ability to detect whether a channel (or frequency band) is being used and if the channel is not being used, the cognitive radio must reconfigure itself to operate on that channel. Thus, cognitive radios should possess a high degree of reconfigurability, so that they can operate in a very wide frequency range. This requires the use of VCOs with a wide tunning range. This work presents a complete design of a LC-VCO with a wide operating frequency range (widedand). A wide tunning range has been obtained from the switching (or programming) the value of the total capacitance of the LC-tank of the VCO, thereby generating multiple frequency sub-bands. The VCO gain (KVCO) was maintained with small variations for all frequency sub-bands, with an average value of 88.6MHz, with 80MHz and 112MHz for the minimum and maximum values, respectively. The phase noise ranged from -118.4dBc/Hz to -107.4dBc/Hz for carriers at 3.7GHz and 8.1GHz, respectively, while the power dissipated in the LC-VCO circuit ranged from 1.8mW to 5.6mW for all tunning range. For the figure of merit power-frequency-tuning-normalized (FOMPFTN), the results were in the 3.1dB to 11.2dB range, comparable to most recently published works.
138

Relógio atômico a feixe efusivo de 133Cs: estudo da estabilidade e da acuracia como função do deslocamento da frequência atômica devido ao efeito zeeman de segunda ordem, ao cavity pulling e ao rabi pulling / A 133Cs Atomic Beam Clock: study of its accuracy and stability as a function of the atomic frequency shift due to the second order zeeman effect, the cavity pulling and the rabi pulling

Aida Bebeachibuli 21 March 2003 (has links)
Em 1967, a definição do segundo passou a ser baseada nas propriedades atômicas dos átomos de 133Cs. O instrumento utilizado para reproduzir esta definição é um relógio atômico. Neste trabalho iremos apresentar os progressos feitos no programa brasileiro de metrologia científica de tempo e freqüência. A proposta deste trabalho de dissertação é a caracterização do nosso padrão. Nós estudaremos os deslocamentos presentes em um relógio atômico, como o efeito Zeeman Quadrático, &#916; &#957;/ &#957;0 =5,4×10-13 o ?Cavity Pulling?, &#916; &#957;/ &#957;0 = 1,27×10-13 e o ?Rabi Pulling?, &#916;&#957;/&#957;0 =1,3×10?13 entre outros, que são induzidas na freqüência hiperfina do césio. Os resultados obtidos neste trabalho podem ser resumidos da seguinte forma: uma incerteza global de 1,44×10-12 e uma estabilidade a curto prazo dada pela raíz quadrada da variância de Allan 1,8×10-10&#932;-0,5. Estes resultados foram medidos após as seguintes mudanças efetuadas em nosso padrão: determinamos a potência ótima injetada na cavidade afim de aumentar o sinal e assegurar que os átomos sofram uma transição &#960;/2; melhoramos o controle do campo magnético estático aplicado ao longo da cavidade de interrogação resultando em um campo magnético mais homogêneo; e, diminuímos a temperatura de operação do forno do relógio tal que a velocidade média dos átomos presente no feixo atômico diminui significativamente. Todas estas mudanças resultaram no ganho de uma ordem de grandeza na acuracia e na estabilidade de nosso relógio. / Since 1967, the definition of the second is based on the atomic properties of the 133Cs atom. The device that realises this definition is an atomic clock. In this work, we present the progress made in the last year on Brazilian scientific time and frequency program. The aim of this dissertation work is the caracterization of our standard. We report the major sifts present in our atomic clock due to Quadratic Zeeman effect, &#916;&#957;/&#957;0 =5,4×10-13 Cavity Pulling, &#916;&#957;/&#957;0 =1,27×10-13 Rabi Pulling, &#916;&#957;/&#957;0 =1,3×10-13 and other ones, which induced a shift in the hiperfine levels frequency of the performances: a global uncertainty of 1,44×10-12 and a short term stability of 1,8×10-10&#932;-0,5 .The results were obtained after these changes: we have determined the optimum microwave power injected into the cavity in order to increase the signal and assure that the atoms suffer a &#960;/2 pulse; we have also minimizes the field inhomogeneity by improving the control of the static magntic field along the interaction region; we have decreased the temperature of the clock oven in order to obtain a slower atomic beam. All this changes has increased our accuracy and our stability of about one order.
139

Proposição de uma metodologia para avaliação de inversores de freqüência em estações elevatórias de água: estudo de casos no sistema de abastecimento de água de São José dos Campos. / Proposal of methodology to evaluation of variable frequency drives in water pumping stations: case study in water supply system in the city of São José dos Campos.

Breno Botelho Ferraz do Amaral Gurgel 19 October 2006 (has links)
Este trabalho avalia a aplicação de inversores de freqüência realizada em estações elevatórias de água tratada da cidade de São José dos Campos que são monitoradas pelo Centro de Controle Operacional da Sabesp. Foram estudadas as características técnicas de quatro sistemas de bombeamento que operam com velocidade variável. O trabalho apresenta uma proposta de metodologia para a seleção de inversores de freqüência, com base na metodologia recomendada pelo EUROPUMP e HYDRAULIC INSTITUTE (2004) aplicada em quatro sistemas da cidade de São José dos Campos. Essa proposta de metodologia foi executada através da avaliação seqüencial de um fluxograma e da análise gráfica das informações instantâneas e históricas dos parâmetros de vazão, pressão e freqüência de rotação, existentes no banco de dados dos servidores de supervisão e controle do Centro de Controle Operacional de São José dos Campos. Após a aplicação dessa metodologia, conclui-se que, a aplicação de inversores de freqüência nos sistemas estudados estava adequada e recomenda-se a sua aplicação em sistemas de bombeamento semelhantes. / The main purpose of this work is to evaluate the application of Variable Frequency Drives ? VFD, carried out in water pumping stations managed by SABESP ? Companhia de Saneamento Básico do Estado de São Paulo, located in the city of Sâo José dos Campos that are monitored by the Operational Control Center ? O.C.C. Technical characteristics of four pumping systems were studied, mainly those operating with fixed or changeable speed. It proposes a new methodology for VFD selection, based on the methodology recommended by EUROPUMP and HYDRAULIC INSTITUTE (2004), used on the systems mentioned before. This proposal of methodology were done using instantaneous and historical information of flow, pressure and rotation frequency parameters stored on data base installed on supervision and control servers installed. After this application, we also concluded that the use of VFD on the evaluated systems was correct and through this we recommend its use on similar pumping systems.
140

Estudo dos polimorfismos das paraoxonases 1 e 2 em pacientes portadores do vírus da imunodeficiência humana e avaliação do potencial de peroxidação lipídica / Frequency of the Paraoxonase 1 and 2 genetic polymorphisms and analysis of the lipid peroxidation in plasma of HIV positive patients

Luciana Morganti Ferreira Maselli 11 September 2007 (has links)
A paraoxonase sérica humana (PON) vem sendo amplamente estudada. Além da capacidade de PON1 em hidrolisar compostos organofosfatados, sabe-se, atualmente, que toda a família PON (composta por PON1, PON2 e PON3) promove a proteção de lípides, incluindo-se a lipoproteína de baixa densidade (LDL) contra a oxidação. O gene da PON1 sérica apresenta dois sítios polimórficos bem determinados: a troca Gln192Arg (Q/R) e Met55Leu, os quais estão associados com diferenças na atividade e concentrações séricas da enzima, respectivamente. Também o polimorfismo Cys311Ser parece contribuir sinergisticamente com o alelo PON1-192R quanto ao risco cardiovascular em algumas populações. Já foi demonstrado, por sua vez, que pacientes infectados pelo vírus HIV podem desenvolver dislipidemia e que tanto a atividade como a concentração de PON1 podem ser influenciadas por esta infecção. O objetivo deste estudo foi determinar as freqüências alélicas dos polimorfismos genéticos PON1-192QR, PON1-55LM, PON2-311SC e PON2-148AG, bem como avaliar a atividade de PON1 e a peroxidação lipídica no plasma de indivíduos portadores de HIV. Materiais e Métodos após aprovação pela comissão de ética e da aplicação do termo de consentimento pós-esclarecido, 350 (264 homens e 86 mulheres) pacientes infectados pelo HIV foram incluídos no estudo. Foi avaliado ainda um grupo de 32 (23 homens e 9 mulheres) indivíduos recentemente diagnosticados como portadores do vírus. Uma população saudável composta por 179 doadores de sangue, todos de sexo masculino, foi avaliada como controle. Após a extração do DNA, procedeu-se à genotipagem para os polimorfismos de PON1 e PON2 através de PCR-RFLP. A atividade paraoxonase de PON1 foi avaliada por espectrofotometria empregando-se paraoxon como substrato. O colesterol total, VLDL-colesterol, HDL-colesterol e triglicérides foram determinados por métodos padrão. A fração LDL-colesterol foi calculada pela fórmula de Friedwald. Resultados As freqüências alélicas para os polimorfimos de PON1 nos pacientes foram: 36,43% para o alelo PON1-192R, 57,86% para PON1-55L, 65,57% para PON2-311S e 76,43% para o alelo PON2-148A. No grupo de indivíduos recentemente diagnosticados como portadores de HIV estas freqüências foram 37,50%, 51,56%, 81,25% e 68,75, respectivamente. No grupo composto pelos saudáveis, a freqüência alélica de PON1-192R foi 43,02%, a de PON1-55L foi 68,99%, a do alelo PON2-311S foi 67,60% e, por fim, a freqüência do alelo PON2-148A foi 75,14%. Conclusões As distribuições alélicas dos polimorfimos em PON1 e PON2 foram similares dentre os portadores de HIV e os controles. A relação entre os genótipos PON1-192QR e/ou PON1-55LM e a atividade de PON1 em pacientes não diferiu daquela observada nos controles. Observou-se ainda, aumento do colesterol, dos triglicérides e da peroxidação lipídica no plasma dos infectados pelo vírus e, nos pacientes, uma maior atividade enzimática dentre os possuidores de contagem de linfócitos CD4+ acima de 500 células por mm3. / Human serum paraoxonase (PON) has been the subject of a number of studies. Beside the capacity of PON1 in hydrolyzing organophosphate compounds, it is known now that the entire PON family (which comprises PON1, PON2 and PON3) protects lipids, including low-density lipoprotein (LDL), from oxidation. Serum PON1 gene presents two well-determined genetic polymorphic sites: a Gln192 Arg (Q/R) and Met55 Leu, which are associated with differences in enzymatic activity and serum concentrations, respectively. Moreover, PON2 Cys311 Ser polymorphism seems to contribute synergistically with PON-192R allele to cardiovascular risk in some populations. It has been shown that HIV infected patients may develop dyslipidemia and that PON1 activity and concentration may be influenced by this infection. The aim of this study was to determine allelic frequencies of PON1-192QR, PON1-55LM, PON2-311SC and PON2-148AG genetic polymorphisms, evaluate PON1 activity and lipid peroxidation in plasma of HIV patients. Methods and Subjects after ethical committee approval and written consent, 350 (264 men and 86 women) HIV infected patients were included in the study. It was also evaluated a group of 32 recently diagnosed HIV individuals (23 men and 9 women). As controls, a healthy population formed by 179 men, blood donors, was studied. After DNA extraction PON1 and PON2 genotyping were performed by PCR-RFLP. Paraoxonase activity of PON1 was evaluated spectrofotometrically using paraoxon as substrate. Serum cholesterol, VLDL-cholesterol, HDL-cholesterol and triglycerides were analyzed by standard methods. LDL-cholesterol was calculated by Friedewald formula. Results: Allelic frequencies for PON1 polymorphisms in patients were: 36,43% for PON1-192R, 57,86% for PON1-55L, 65,57% for PON2-311S and 76,43% for PON2-148A. In recently diagnosed individuals these frequencies were 37,50%, 51,56%, 81,25% and 68,75% respectively. In controls, PON1-192R allelic frequency was 43,02%, PON1-55L was 68,99%, PON2-311S was 67,60% and PON2-148A was 75,14%. Conclusion: Allelic distributions of PON1 and PON2 polymorphisms were similar in HIV patients and controls. The relationship between PON1-192 QR and/or PON1-55LM genotypes and enzyme activity in patients were not different from controls. It was also observed an elevation of cholesterol, tryglicerides and lipid peroxidation levels in plasma of infected patients and, in this group, a higher activity in those which CD4+ cells counting was more than 500 cell/mm3.

Page generated in 0.5989 seconds