11 |
Analytical and Experimental Study of Annular Two-Phase Flow Friction Pressure Drop Under MicrogravityNguyen, Ngoc Thanh 2009 December 1900 (has links)
Two-phase liquid-gas flow has a wide variety of applications in space, including active thermal control systems, high-power communications satellites, heat pumps and space nuclear reactors. Two-phase systems have many potential advantages over current single-phase systems due to reductions in system size, weight and power consumption. The mechanisms of pressure drop, heat transfer coefficients, void fractions, and flow regimes must be well understood under microgravity conditions in order to design reliable two-phase systems. The main objective of this present research is to develop a new mathematical model that can accurately predict the annular two-phase friction pressure drop to optimize the design of two-phase systems. The two-phase flow tests were conducted aboard the NASA KC-135 aircraft by the Interphase Transport Phenomena (ITP) group from Texas A&M University. The two-phase flow pressure drops were measured across a single transparent test section 12.7 mm ID and 1.63 m long in annular regimes under microgravity conditions during two flight campaigns. Different from previous work, this was the first time both the void fraction and the film thickness were measured under microgravity conditions. The empirical correlations for the interfacial friction factor and void fraction were developed from 57 experimental data using a linear least squares regression technique. The annular two-phase friction pressure drop can be predicted by the new mathematical model requiring only knowledge of the length and diameter of the tube, liquid and vapor mass flow rates, and properties of the working fluid. In addition, the new mathematical model was validated using Foster-Miller & ITP data collected over twelve flights aboard the KC-135 with working fluid R-12 (77 data points), Sundstrand data collected aboard the KC-135 with working fluid R-114 (43 data points) and Zhao and Rezkallah data aboard the KC-135 with working fluid water and air (43 data points). Compared with the LockhartMartinelli model, Wheeler model, Chen model and homogeneous model, the new mathematical model is the optimal model for predicting the two-phase friction pressure drop in annular regimes. The majority of the data falls within +-20% of the proposed correlation and the average error is 12%.
|
12 |
Análise da influência das propriedades do material e parâmetros do processo na simulação numérica do processo de forjamentoLenhard Júnior, Adalberto Luiz January 2007 (has links)
Este trabalho tem como objetivo investigar quais são os valores dos principais parâmetros que a literatura apresenta para o processo de forjamento a morno de precisão. Os parâmetros escolhidos são: curva de escoamento do SAE-1050M a frio e a quente, fator de atrito e o coeficiente de transferência de calor entre peça e ferramenta. Estipulou-se uma faixa de variação destes parâmetros, simulou o processo através do método dos elementos finitos com o uso do pacote MSC.Superform 2005 para os diferentes parâmetros e cruzou os resultados por meio do conceito de sensitividade. Os resultados cruzados são: força, trabalho, deformação e temperatura. Simulações são realizadas com variações dos parâmetros de entrada baseadas nos ensaios e levantamento bibliográficos. As respostas das simulações são adimensionalizadas com o uso do conceito de sensitividade, podendo assim, serem comparadas entre si. O fator de atrito e o coeficiente de transferência de calor entre peça e ferramenta não influenciam tanto na resposta como a curva de escoamento. / This work has as objective to investigate which values of key parameters are presented by the literature for the warm precision forging process. The chosen parameters are: hot and cold SAE-1050M flow stress curve, friction factor and heat transfer coefficient between workpiece and die. Stipulate a range of variation of these parameters, simulate the process through the finite elements method with the use of the package MSC.Superform 2005 with different parameters and cross the results with concept of sensitivity. The crossed results are: force, work, strain and temperature. Simulations are carried out with variations of the input parameters based on the bibliographical research and tests. The simulations output are nondimensionalised with the use of the sensitivity concept, thus being able, to be comparative between themselves. The friction factor and the heat transfer coefficient between workpiece and die do not influence as much as the flow stress curve.
|
13 |
Análise de comparação entre elitismos na calibração de fatores de atrito em redes hidráulicas por meio do método transiente inverso com aplicação de algoritmo genético / Comparison between elitisms in the calibration of friction factors in hydraulic networks by means of the inverse transient method with application of genetic algorithmSilva, Francisco Ícaro Lopes da 13 July 2017 (has links)
SILVA, F. I. L. Análise de comparação entre elitismos na calibração de fatores de atrito em redes hidráulicas por meio do método transiente inverso com aplicação de algoritmo genético. 2017. 111 f. Dissertação (Mestrado em Engenharia Civil)-Centro de Tecnologia, Programa de Pós-Graduação em Engenharia Civil: Recursos Hídricos, Universidade Federal do Ceará, Fortaleza, 2017. / Submitted by Edineuza Silva (edineuza@deha.ufc.br) on 2017-09-12T17:23:35Z
No. of bitstreams: 1
2017_dis_filsilva.pdf: 2946864 bytes, checksum: 44409fd6978ae5f8244a2a0fc63e777c (MD5) / Rejected by Marlene Sousa (mmarlene@ufc.br), reason: Prezado Icaro, Existe uma orientação para que normalizemos as dissertações e teses da UFC, em suas paginas pré-textuais e lista de referencias, pelas regras da ABNT. Por esse motivo, sugerimos consultar o modelo de template, para ajudá-lo nesta tarefa, disponível em: http://www.biblioteca.ufc.br/educacao-de-usuarios/templates/
Vamos agora as correções sempre de acordo com o template:
1. Na folha de aprovação falta colocar a informação título de mestre em:XXXXXX e a área de concentração.
2. Já que vc fez listas separadas coloque o termo LISTA DE FIGURAS substituindo lista de ilustrações. Substitua os dois pontos por hífen para separar a numeração das figuras do título. Ex Figura 3.1 - Algoritmo genético típico
Nas listas de figuras e tabelas observe o alinhamento da margem que deve ser igual ao que vc fez na lista de abreviaturas e siglas. De modo que quando aumentar o número de dígitos das figuras elas fiquem no mesmo alinhamento de quando tinham menos dígitos. Ex Figura 6.9 e 6.10 e as Tabela 6.9 e 6.10.
Nas LISTA DE FIGURAS e LISTA DE TABELAS, Quando o título da figura ou da tabela não couber na mesma linha, sua continuação deve ficar na mesma margem da primeira letra da linha de cima e não voltar para a margem do F de Figura ou do T de Tabela.
3. No sumário não dê recuo na margem. Observe o alinhamento a esquerda, uso de negrito, maiúsculo e itálico nas seções de acordo com template.
4. Na lista de REFERÊNCIAS a palavra deve ser centralizada na folha.
Ao abreviar as edições dos livros use a forma 2. ed. corrija em toda a lista onde aparecer a informação de edição.
Nas referencias de livros a ordem dos elementos deve ser local de publicação: nome de editora, data de publicação.
Qualquer dúvida estou a disposição.
Att. Marlene Rocha
3366-9620
mmarlene@ufc.br
on 2017-09-13T12:17:31Z (GMT) / Submitted by Edineuza Silva (edineuza@deha.ufc.br) on 2017-09-15T11:32:21Z
No. of bitstreams: 1
2017_dis_filsilva.pdf: 2946864 bytes, checksum: 44409fd6978ae5f8244a2a0fc63e777c (MD5) / Rejected by Marlene Sousa (mmarlene@ufc.br), reason: Neusa: devolvo como vc pediu. on 2017-09-15T12:11:10Z (GMT) / Submitted by Edineuza Silva (edineuza@deha.ufc.br) on 2017-09-15T12:34:54Z
No. of bitstreams: 1
2017_dis_filsilva.pdf.pdf: 2870997 bytes, checksum: c52dedabde2a98548c62103c0c2feb27 (MD5) / Rejected by Marlene Sousa (mmarlene@ufc.br), reason: Prezado Ícaro: Falta ainda corrigir de acordo com template http://www.biblioteca.ufc.br/educacao-de-usuarios/templates/
1. Resumo e Abstract não devem ter parágrafo. Devem ser alinhados a esquerda. Retire parágrafo da primeira linha.
2. Na lista de Figuras, a 6.2 está fora do alinhamento da margem.
3. O sumário deve ser todo em negrito com exceção das seções quaternárias (4 dígitos) que ficam só em itálico.
O sumário continua sem alinhamento da margem. Deixe bastante espaço entre o algarismo 1 e a palavra Introdução, de modo que esse espaço seja suficiente para quando aumentarem o numero de dígitos das seções estas fiquem com o mesmo alinhamento. Sendo assim, a letra A de Aspectos gerais, fica em baixo do I de INTRODUÇÃO, assim como o M de Método de tentativa e erro deve ficar em baixo da letra I de INTRODUÇÃO. Ou seja, no mesmo alinhamento da margem.
O C de CONCLUSÕES deve ficar no mesmo alinhamento da margem do I de INTRODUÇÃO. E o R de REFERENCIAS também na mesma margem e em baixo do C de CONCLUSÕES.
Qualquer dúvida estou a disposição
Marlene on 2017-09-15T14:27:39Z (GMT) / Submitted by Edineuza Silva (edineuza@deha.ufc.br) on 2017-10-18T13:54:54Z
No. of bitstreams: 1
2017_dis_filsilva.pdf: 2873584 bytes, checksum: b9b26e4e21ad8e9a363117297c9d7e58 (MD5) / Rejected by Marlene Sousa (mmarlene@ufc.br), reason: Prezado Francisco, Seu trabalho ficou desconfigurado a partir da folha de dedicatória. Uma folha está subindo para a outra. Corrija por favor. No mais tudo certo.
Marlene
mmarlene@ufc.br on 2017-10-20T17:21:37Z (GMT) / Submitted by Edineuza Silva (edineuza@deha.ufc.br) on 2017-10-24T11:41:57Z
No. of bitstreams: 1
2017_dis_filsilva.pdf: 2871661 bytes, checksum: 586de76c264e3316eaf2ba5ef73cfa24 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2017-11-07T19:05:23Z (GMT) No. of bitstreams: 1
2017_dis_filsilva.pdf: 2871661 bytes, checksum: 586de76c264e3316eaf2ba5ef73cfa24 (MD5) / Made available in DSpace on 2017-11-07T19:05:23Z (GMT). No. of bitstreams: 1
2017_dis_filsilva.pdf: 2871661 bytes, checksum: 586de76c264e3316eaf2ba5ef73cfa24 (MD5)
Previous issue date: 2017-07-13 / For some time, due to its complexity, the calibration of parameters in transient hydraulic networks was neglected. However, studies related to this phenomenon, especially with respect to the friction factor have been growing in recent times. Simulations of the equilibrium conditions of a hydraulic distribution network become one of the most important steps in the technical analysis of water supply systems. In order to identify and estimate the parameters of a hydraulic network, from observed data of transient loads, a computational model was developed. In general, the physical parameters of the network such as friction factors, absolute roughness, diameters and the identification, measurement and quantification of leaks are unknown quantities. This work aims at the identification and calibration of the friction factors by means of a combination of the Inverse Transient Method - MTI - with the Genetic Algorithm - AG. Next to this combination was used the Method of Characteristics - MOC - to solve the equations of the flow in permanent and transient regime in networks of pipes. The hypothetical hydraulic net under analysis consists of eight variable demand nodes, ten tubes and a quota reservoir equivalent to 60m, being submitted to a 30s transient. The analyzes were performed through programs that apply the technique of optimization of the genetic algorithm to find the optimal values of the hydraulic load in the observed node. A comparative study will be carried out between two types of elitism in order to evaluate the effects produced in the identification and calibration of the friction factors in transient conditions. The steady state conditions are known. Five elitism rates were applied to each initial population in order to analyze the influence on the calibration result. Elitism 2 presented smaller errors than elitism 1, both for the average processing and for better processing, even with higher objective functions. The rate of best efficiency for the application of elitism 1 and 2 was 70%. The hydraulic transient is directly related to the definition of the parameters of the genetic algorithm. / Durante algum tempo, devido a sua complexidade, a calibração de parâmetros em redes hidráulicas em regime transiente foi negligenciada. Entretanto, os estudos relacionados a esse fenômeno, sobretudo no que diz respeito ao fator de atrito vêm crescendo nos últimos tempos. As simulações das condições de equilíbrio de uma rede de distribuição hidráulica tornam-se uma das etapas mais importantes na análise técnica de sistemas de abastecimento de água. Com o fito de identificar e estimar os parâmetros de uma rede hidráulica, a partir de dados observados de cargas transientes, desenvolveu-se um modelo computacional. De uma maneira geral, os parâmetros físicos da rede como fatores de atrito, rugosidades absolutas, diâmetros e a identificação, mensuração e quantificação de vazamentos são grandezas desconhecidas. Este trabalho tem como escopo a identificação e calibração dos fatores de atrito por meio de uma combinação do Método Transiente Inverso – MTI – com o Algoritmo Genético – AG. Junto a essa combinação utilizou-se o Método das Características – MOC – para resolução das equações do escoamento em regime permanente e transiente em redes de tubulações. A rede hidráulica hipotética em análise é formada por oito nós de demanda variável, dez tubos e um reservatório de cota equivalente a 60m, sendo submetida a um transiente de 30s. As análises foram realizadas através de programas que aplicam a técnica de otimização do algoritmo genético para encontrar os valores ótimos da carga hidráulica no nó observado. Será trabalhado o estudo comparativo entre dois tipos de elitismo com a finalidade de avaliar os efeitos produzidos na identificação e calibração dos fatores de atrito em condições transientes. As condições de regime permanente são conhecidas. Aplicaram-se cinco taxas de elitismo à cada população inicial, de modo a analisar a influência no resultado da calibração. O elitismo 2 apresentou erros menores do que o elitismo 1, tanto para a média dos processamentos como para o melhore processamento, mesmo apresentando funções objetivo maiores. A taxa de melhor eficiência para a aplicação do elitismo 1 e 2 foi a de 70%. O transiente hidráulico tem relação direta com a definição dos parâmetros do algoritimo genético.
|
14 |
Análise da influência das propriedades do material e parâmetros do processo na simulação numérica do processo de forjamentoLenhard Júnior, Adalberto Luiz January 2007 (has links)
Este trabalho tem como objetivo investigar quais são os valores dos principais parâmetros que a literatura apresenta para o processo de forjamento a morno de precisão. Os parâmetros escolhidos são: curva de escoamento do SAE-1050M a frio e a quente, fator de atrito e o coeficiente de transferência de calor entre peça e ferramenta. Estipulou-se uma faixa de variação destes parâmetros, simulou o processo através do método dos elementos finitos com o uso do pacote MSC.Superform 2005 para os diferentes parâmetros e cruzou os resultados por meio do conceito de sensitividade. Os resultados cruzados são: força, trabalho, deformação e temperatura. Simulações são realizadas com variações dos parâmetros de entrada baseadas nos ensaios e levantamento bibliográficos. As respostas das simulações são adimensionalizadas com o uso do conceito de sensitividade, podendo assim, serem comparadas entre si. O fator de atrito e o coeficiente de transferência de calor entre peça e ferramenta não influenciam tanto na resposta como a curva de escoamento. / This work has as objective to investigate which values of key parameters are presented by the literature for the warm precision forging process. The chosen parameters are: hot and cold SAE-1050M flow stress curve, friction factor and heat transfer coefficient between workpiece and die. Stipulate a range of variation of these parameters, simulate the process through the finite elements method with the use of the package MSC.Superform 2005 with different parameters and cross the results with concept of sensitivity. The crossed results are: force, work, strain and temperature. Simulations are carried out with variations of the input parameters based on the bibliographical research and tests. The simulations output are nondimensionalised with the use of the sensitivity concept, thus being able, to be comparative between themselves. The friction factor and the heat transfer coefficient between workpiece and die do not influence as much as the flow stress curve.
|
15 |
A InfluÃncia de manobras de vÃlvulas na identificaÃÃo do fator de atrito em tubulaÃÃes de rede de distribuiÃÃo de Ãgua / The Influence valves maneuvers in friction factor identification in network of pipes distribution of waterFrancisco Marques Viana 03 December 2014 (has links)
Um avanÃo importante na modelagem de rede hidrÃulica foi a calibraÃÃo, atravÃs desta Ã
possÃvel conhecer o comportamento das caracterÃsticas fÃsicas da rede, sendo esta de grande
importÃncia nas tomadas de decisÃo. Neste trabalho vamos utilizar o mÃtodo transiente inverso
aplicado com algoritmo genÃtico, para calibraÃÃo dos fatores de atritos das tubulaÃÃes de uma
rede de distribuiÃÃo de Ãgua por meio de simulaÃÃes a partir da variaÃÃo de parÃmetros
como: nÃmero de cromossomos, nÃmero de geraÃÃes, cruzamento de um ponto e mutaÃÃo
simples, quantidade de nÃs medidos, e diferentes tipos de manobras de vÃlvulas (brusca e
suave). As simulaÃÃes foram divididas em casos, onde cada soluÃÃo encontrada pelo
modelo computacional foi avaliada por uma funÃÃo objetiva, baseada na diferenÃa quadrÃtica
entre resultados observados e calculados para as cargas transientes no(s) nÃ(s) monitorado(s).
As anÃlises das soluÃÃes encontradas demonstram como o mÃtodo inverso, o algoritmo
genÃtico e a escolha de seus parÃmetros influenciam o resultado final. Por meio dos casos,
observou-se que para as redes estudadas, nÃo adianta simplesmente aumentar isoladamente os
valores dos parÃmetros do algoritmo genÃtico no intuito de melhorar a eficiÃncia do
mÃtodo. Como se trata de um mÃtodo inverso, uma combinaÃÃo especÃfica de fator de atrito foi
gerada a partir da mÃdia das soluÃÃes obtidas, sob os mesmos parÃmetros, em dez
aplicaÃÃes sucessivas do algoritmo genÃtico (processamentos). Os resultados apresentados para as
cargas hidrÃulicas no(s) nÃ(s) monitorado(s) foram bem prÃximas das cargas consideradas reais
(observadas), tendo em alguns trechos das tubulaÃÃes valores para a forÃa de atrito bem
prÃximos dos considerados reais. A eficiÃncia dos resultados encontrados foi medida por meio
da FunÃÃo Objetiva. / An important advance in the hydraulic network modeling was the calibration through this is
possible to know the behavior of the physical characteristics of the network, which is of great
importance in decision-making. In this work we will use the reverse transient method
applied with genetic algorithm for calibration of friction factors pipes of a
water distribution network through simulations from the variation of parameters
as the number of chromosomes, number of generations, passing a point mutation and
simple, we measured quantity, and different types of maneuvering valve (sudden and
soft). The simulations were divided into instances, wherein each solution found by
computational model was evaluated by an objective function based on square difference
between observed and calculated results for the transient loads in (s) node (s) monitored (s).
The analyzes of the solutions shown as the inverse method, the algorithm
genetic and the choice of its parameters influence the final result. Through cases,
it was observed that for the studied networks, no use simply alone increase
values ​​of the parameters of the genetic algorithm in order to improve the efficiency of
method. As this is an inverse method, a specific combination of friction factor was
generated from the average of these solutions under the same parameters in ten
successive applications of genetic algorithm (processing). The results reported for
hydraulic loads in (s) node (s) monitored (s) were very close considered the actual loads
(Observed), in some parts of pipes values ​​for the friction force and
considered close to real. The efficiency of the results was measured by
Function Objetiv
|
16 |
Análise da influência das propriedades do material e parâmetros do processo na simulação numérica do processo de forjamentoLenhard Júnior, Adalberto Luiz January 2007 (has links)
Este trabalho tem como objetivo investigar quais são os valores dos principais parâmetros que a literatura apresenta para o processo de forjamento a morno de precisão. Os parâmetros escolhidos são: curva de escoamento do SAE-1050M a frio e a quente, fator de atrito e o coeficiente de transferência de calor entre peça e ferramenta. Estipulou-se uma faixa de variação destes parâmetros, simulou o processo através do método dos elementos finitos com o uso do pacote MSC.Superform 2005 para os diferentes parâmetros e cruzou os resultados por meio do conceito de sensitividade. Os resultados cruzados são: força, trabalho, deformação e temperatura. Simulações são realizadas com variações dos parâmetros de entrada baseadas nos ensaios e levantamento bibliográficos. As respostas das simulações são adimensionalizadas com o uso do conceito de sensitividade, podendo assim, serem comparadas entre si. O fator de atrito e o coeficiente de transferência de calor entre peça e ferramenta não influenciam tanto na resposta como a curva de escoamento. / This work has as objective to investigate which values of key parameters are presented by the literature for the warm precision forging process. The chosen parameters are: hot and cold SAE-1050M flow stress curve, friction factor and heat transfer coefficient between workpiece and die. Stipulate a range of variation of these parameters, simulate the process through the finite elements method with the use of the package MSC.Superform 2005 with different parameters and cross the results with concept of sensitivity. The crossed results are: force, work, strain and temperature. Simulations are carried out with variations of the input parameters based on the bibliographical research and tests. The simulations output are nondimensionalised with the use of the sensitivity concept, thus being able, to be comparative between themselves. The friction factor and the heat transfer coefficient between workpiece and die do not influence as much as the flow stress curve.
|
17 |
Termofluidodinamica de sucos de frutas pseudoplasticos em dutos cilindricos e anulos concentricos / Thermo-fluid dynamics to pseudoplastic fruit juices in cilindrical ducts and concentric annuliGratão, Ana Carolina Amaral 17 April 2006 (has links)
Orientadores: Vivaldo Silveira Junior, Javier Telis Romero / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-06T15:00:42Z (GMT). No. of bitstreams: 1
Gratao_AnaCarolinaAmaral_D.pdf: 2034155 bytes, checksum: 7a7cc4a961cab6b38ae3dc5ee5f3f9d8 (MD5)
Previous issue date: 2006 / Doutorado / Engenharia de Alimentos / Doutor em Engenharia de Alimentos
|
18 |
Experimental Characterization and Modeling of Wettability in Two Phase Oil/Water Flow in the Annular Flume ApparatusBlake, Kevin 04 June 2019 (has links)
No description available.
|
19 |
Shale Shaker Model and Experimental ValidationRaja, Vidya 01 August 2012 (has links)
No description available.
|
20 |
Numerical Investigation of Fluid Flow and Heat Transfer for Non-Newtonian Fluids Flowing through Twisted Ducts with Elliptical Cross-sectionsModekurti, Arvind 07 November 2017 (has links)
No description available.
|
Page generated in 0.1093 seconds