• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 692
  • 11
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 715
  • 345
  • 295
  • 219
  • 196
  • 175
  • 162
  • 150
  • 140
  • 139
  • 136
  • 136
  • 125
  • 117
  • 106
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Progesterone-based fixed-time artificial insemination protocols for dairy cows / Protocolos de inseminação artificial em tempo fixo à base de progesterona para vacas leiteiras

Melo, Leonardo de França e 01 August 2016 (has links)
In the last 50 years, milk production increased in lactating dairy cows. In contrast, reproductive efficiency has dramatically decreased. Several causes may be involved, such as management and environmental factors, physiological and nutritional factors, disease challenges and others. Steroid hormone concentrations in high-producing lactating dairy cows are often at lower levels, due to high dry matter intake and increased liver blood flow and steroid hormones metabolism, which is associated with the compromised estrus expression and reduced oocyte quality, thus decreasing fertility. However, with the largely use of FTAI programs, fertility has turned the corner with current reports of increasing reproductive efficiency. Given the great number and variations on E2/P4-based FTAI protocols, three studies were performed involving different hormonal combinations and are presented in two chapters in this thesis. The first study aimed to compare the ovarian dynamics and fertility using two different treatments at the initiation of a P4-based FTAI protocol, GnRH vs. EB, combined with two different treatments at the end of the protocol, EB vs. ECP. For this study, 1,035 lactating cows were completely randomized into one of four treatments: GnRH-EB, GnRH-ECP, EB-EB, EB-ECP. Interactions and treatments at the end of the protocol did not affect fertility. However, GnRH rather than EB at the beginning tended to increase P/AI and greater proportion of cows regressed the CL when EB was used. The second study aimed to compare plasma P4 concentrations in non-lactating Holstein cows fitted implanted with new (New), or 8-days used intravaginal P4 implants previously autoclaved (Aut) or disinfected (Dis), and containing 1.9 or 1.0 g of P4. Using a 2x3 factorial arrangement of treatments, 24 cows were randomly assigned to two of six treatment groups (two replicates). Mean circulating P4 during 8 days with P4 implant were the following regarding treatments: 1.9 g > 1.0 g; 1.9 g: Aut > New > Dis; 1.0 g: Aut = New > Dis (P < 0.05). The third experiment was performed with 349 cows in two farms and aimed to compare P4 concentrations, ovarian dynamics and fertility during use of 1.9 g Aut or Dis intravaginal P4 implants, in lactating Holstein cows submitted to a 10-day long E2/P4-based FTAI protocol, combined with GnRH treatment at the beginning of the protocol. Slight variations in P4 concentrations were observed between treatments, which did not affect follicular dynamics, synchronization rate or P/AI. However, presence of CL or ovulation at the beginning of the FTAI protocol affected several reproductive variables, such as the time and synchronization of the follicular wave emergence, proportion of cows in estrus at the end of the protocol and size of the ovulatory follicle, and more overall synchronized cows became pregnant to the FTAI protocol. / A produção de leite em bovinos aumentou consideravelmente nos últimos 50 anos. Inversamente, a eficiência reprodutiva vem diminuindo consistentemente. Vários fatores estão envolvidos, tais como manejo e ambiência, fatores fisiológicos e nutricionais, desafios sanitários, entre outros. As concentrações sanguíneas de hormônios esteroides em vacas leiteiras são baixas, devido à elevada ingestão de matéria seca e ao elevado fluxo sanguíneo hepático e metabolismo, os quais estão associados às alterações na expressão do estro e na qualidade de gametas, reduzindo assim a fertilidade. Entretanto, com o largo uso de programas de IATF, a fertilidade vem aumentado bem como a eficiência reprodutiva. Em função da grande quantidade e variações nos protocolos de IATF à base de E2/P4, três estudos foram realizados envolvendo diferentes combinações hormonais, os quais estão apresentados em dois capítulos desta tese. O primeiro estudo objetivou comparar a dinâmica ovariana e a fertilidade com o uso de dois tratamentos hormonais ao início do protocolo à base de P4, GnRH vs. BE, combinados com dois tratamentos no final do protocolo, BE vs. ECP. Para este estudo, 1.035 vacas lactantes foram aleatorizadas em um de quatro tratamentos: GnRH-BE, GnRH-ECP, BE-BE, BE-ECP. Interações e os tratamentos ao final do protocolo não afetaram a fertilidade. No entanto, o GnRH no início do protocolo tendeu a melhorar a P/IA, comparado ao BE, o qual foi responsável por uma grande proporção de vacas regredindo o CL durante o protocolo. O segundo estudo objetivou comparar as concentrações plasmáticas de P4 em vacas holandesas não lactantes entre dispositivos intravaginais de P4 novos (Novo), ou com 8 dias de uso, previamente autoclavados (Aut) ou desinfetados (Des) e contendo 1,9 ou 1,0 g de P4. Em um arranjo fatorial 2x3, aleatorizou-se 24 vacas em dois dos seis tratamentos (duas réplicas). A P4 circulante média nos 8 dias com implante de P4 foi a seguinte em relação aos tratamentos: 1,9 g > 1,0 g; 1,9 g: Aut > Novo > Des; 1,0 g: Aut = Novo > Des (P < 0.05). O terceiro experimento objetivou comparar as concentrações de P4, a dinâmica ovariana e a fertilidade durante o uso de implante Aut ou Des com 1,9 g de P4, em 349 vacas holandesas lactantes submetidas a um protocolo de IATF à base de E2/P4, combinado com GnRH no início do protocolo. Pequenas variações foram verificadas entre os tratamentos nas concentrações de P4, porém sem efeito na dinâmica folicular, na taxa de sincronização e na P/IA. Contudo, a ciclicidade ou a ovulação no início do protocolo influenciaram variáveis reprodutivas, tais como o momento e a sincronização da emergência da onda folicular, a proporção de vacas em cio ao final do protocolo e o tamanho do folículo ovulatório. Além disso, mais vacas sincronizadas ao protocolo ficaram gestantes.
172

Avaliação das tensões ósseas geradas por prótese obturadora maxilar implanto-retida pelo sistema ERA® por meio da análise de elementos finitos / Evaluation of bone stress with implant retained obturator prosthesis with ERA® system through finite element analysis

Costa, Valéria Tognato 10 May 2016 (has links)
Visando melhorar a qualidade de vida dos pacientes com perdas de estrutura maxilar faz-se necessária sua reabilitação, seja ela cirúrgica ou protética por meio de próteses obturadoras, esta última, um recurso terapêutico que minimiza os distúrbios funcionais, estéticos e psicológicos. Este estudo avaliou o comportamento biomecânico de prótese obturadora maxilar Classe II de Okay retida por implantes e sistema de retenção ERA®, observando as tensões geradas no tecido gengivo-mucoso e ósseo maxilar. A Análise de Elementos Finitos foi realizada empregando-se um modelo digital desenvolvido a partir da tomografia computadorizada de um indivíduo adulto. Quatro implantes foram posicionados na maxila, em região de incisivo lateral, canino, segundo pré-molar e primeiro molar esquerdos, onde as estruturas do sistema de retenção ERA® foram posicionadas nas extremidades de uma barra metálica e convertidas para serem representadas por superfícies. Utilizou-se o programa Rhinoceros® versão 5.0 para gerar o modelo maxilar BioCAD 3D, incorporando-se os modelos CAD dos implantes, UCLAS e o CAD do sistema de retenção ERA®. O CAD do sistema ERA®, fundido em metal, foi desenvolvido a partir de imagens geradas pelo microCT SkyScan 1176 Bruke no formato BMP e TIFF. Essas imagens no formato TIFF foram exportadas para o software img2dcm, convertidas para o formato DICOM e então exportadas para o software Invesalius que reconstruiu tridimensionalmente gerando uma malha no formato STL. As estruturas finalizadas foram exportadas para software Hyperworks 13.0 e pós-processadas com a visualização de resultados pelo Hyperview, tendo sido aplicada uma força de 80N na plataforma oclusal e de 35N na plataforma incisal. Foi realizada uma análise qualitativa, correspondente à escala de máxima tensão principal e os valores quantitativos expressos em MPa. Ocorreu um deslocamento máximo da prótese obturadora na região sem suporte ósseo, tendo como fulcro a linha de ressecção óssea. Observou-se menos forças de tração do que de compressão. As forças analisadas se mostraram bastante favoráveis à estabilidade da prótese obturadora implanto-retida por se apresentarem bem distribuídas pelo tecido gengivo-mucoso e ósseo da maxila remanescente, indicando que o sistema ERA® de retenção é adequado para reabilitação maxilar das perdas ósseas Classe II de Okay. / Searching to improve quality of life of the patients that had sustained structural maxillary loss with the necessity of rehabilitation, either through surgery or obturator prosthesis, which is a therapeutic resource to minimize functional, esthetic and psychological impairments. This study evaluated the biomechanical behavior of an Okay Class II obturator prosthesis implant retained and ERA® system, analyzing the resultant stress on the soft and bone tissue. The finite element analysis was made with a digital model constructed from a computed tomography. Four implants were positioned on the left maxillae, on the following regions: lateral incisor, canine, second premolar and first molar, with the ERA® system positioned on the extremities of a metallic bar. The software used to create the BioCAD 3D model was Rhinoceros v. 5.0, including the CAD models from the implants, UCLAS and ERA® system. The ERA® CAD model was obtained from a microCT SkyScan 1176 Bruke images, on the BMP and TIFF format. The TIFF images were exported to the img2dcm software, converted in DICOM format and finally exported to the software Invesalius, were the STL mesh was created. All mesh were imported into the software Hyperworks v. 13.0 and the post-processing was visualized on Hyperview. The force applied was of 80N over the occlusal platform and of 35N over the incisal platform. A quantitative analysis was performed, corresponding to the maximum main stress, expressed in MPa. The obturator prosthesis suffered its maximum dislocation on the region with no bone support, with the bone resection line as fulcrum. Less tension forces were observed, when comparing to compression. The forces observed were favorable to maintain the implant retained prosthesis stabilization, with good distribution over the soft and bone tissues, suggesting that the ERA® retention system is suitable to Okay Class II maxillary bone loss.
173

Avaliação da precisão de um guia radiográfico-cirúrgico para inserção de mini-implantes / Accuracy evaluation of a radiographic-surgical guide for mini-implant placement

Barros, Sérgio Estelita Cavalcante 23 June 2008 (has links)
PROPOSIÇÃO Avaliou-se radiograficamente o grau de precisão de um guia radiográfico-cirúrgico na predição do posicionamento final de mini-implantes inseridos no septo inter-radicular e, sequencialmente, determinou-se um índice de risco para normatizar a indicação do procedimento de inserção dos mini-implantes. MATERIAL E MÉTODOS Um total de 53 mini-implantes foram inseridos no septo inter-radicular vestibular da região posterior da maxila e/ou mandíbula de 27 pacientes com idade média de 19,17 ± 9,06 anos (idade mínima de 12,72 anos e máxima de 56,37 anos). O Guia Radiográfico-Cirúrgico Graduado (GRCG) foi utilizado para inserir os mini-implantes no centro do septo de forma equidistante em relação às raízes dos dentes adjacentes. As distâncias entre o mini-implante e as raízes dos dentes adjacentes foram mensuradas nas 53 radiografias pós-cirúrgicas com intuito de avaliar a precisão do GRCG a partir do grau de centralização do mini-implante no septo. O grau de imprecisão do GRCG foi associado à largura do septo e ao diâmetro do mini-implante para compor a fórmula do índice de risco utilizada na avaliação do risco cirúrgico de inserção dos mini-implantes. RESULTADOS O grau de imprecisão do GRCG mostrou que, em média, os mini-implantes foram inseridos com um desvio de 0,13mm (±0,13) em relação ao centro do septo. O valor médio do índice de risco (IR) foi menor do que 1, significando um reduzido risco cirúrgico. CONCLUSÕES A ligação estabelecida entre os procedimentos radiográfico e cirúrgico proveu ao GRCG um reduzido grau de imprecisão de 0,13mm, e uma acurada predição do posicionamento final do mini-implante no septo inter-radicular, contribuindo para um reduzido risco cirúrgico (IR<1). / OBJECTIVE This study evaluated the radiographic-surgical guide accuracy to predict post-surgical mini-implant positioning in the interradicular septum. Additionally, a risk index to standardize surgical procedure indication for mini-implant insertion was determined. MATERIAL AND METHODS A total of fifty-three titanium mini-implants were placed in the buccal interradicular septum of the posterior maxillary and/or mandibular region of 27 patients with a mean age of 19.17 ± 9.06 years (ranging from 12.72 to 56.37 years). The Graduated Radiographic-Surgical Guide (GRSG) was used to insert mini-implants in the interradicular septum in a centralized and equidistant position regarding adjacent tooth roots. The fifty-three post-surgical radiographs were used to measure the distances between mini-implants and adjacent tooth roots to evaluate GRSG accuracy in obtaining mini-implant centralized position in the septum. The GRSG inaccuracy degree was related to the septum width and the mini-implant diameter to obtain risk index formula, which was used to predict surgical risks during mini-implants insertion. RESULTS The GRSG inaccuracy degree showed that, on average, the mini-implants were 0.13mm (±0.13) displaced regarding the centralized position initially intended. The risk index (RI) presented a mean value smaller than 1, indicating a reduced surgical risk. CONCLUSION The link established between radiographic and surgical procedures propitiated a small GRSG inaccuracy degree of 0.13mm, allowing an accurate prediction of the final mini-implant positioning in the interradicular septum, which contributed to a low surgical risk (RI<1).
174

Resolução temporal auditiva de crianças usuárias de implante coclear / Auditory temporal resolution in children using cochlear implantation

Comerlatto Junior, Ademir Antonio 15 July 2011 (has links)
A resolução temporal auditiva é considerada uma das habilidades mais importantes para o processamento do sinal acústico ao longo do tempo. Ela permite identificar diferenças finas dos aspectos segmentais da fala, como a identificação de fonemas, e o início e o final de palavras em frases encadeadas. Crianças usuárias de Implante Coclear (IC) apresentam características próprias de decodificação e processamento do sinal da fala ao longo do tempo, realizada pelo IC. Diante do exposto, esta pesquisa teve por objetivo verificar o desempenho de crianças usuárias de IC em tarefas de resolução temporal. A amostra foi composta por 20 crianças usuárias de IC Nucleus 24/SPRINT (Grupo Experimental - GE) e 20 crianças sem alterações auditivas (Grupo Controle - GC). Foram aplicados o Random Gap Detection Test (RGDT) e o teste Gaps In Noise (GIN) para avaliar a habilidade de resolução temporal por meio de tarefas de detecção de gap. Os testes foram aplicados em campo livre e a 40dBNS. Os testes estatísticos utilizados para a análise dos dados foram o teste t de Student para dados independentes, e o teste de Mann Whitney e o Coeficiente de Correlação de Pearson. As crianças usuárias de IC obtiveram limiares de gap no RGDT de 74,13±51 ms e no teste GIN de 12,12±2,53 ms, sendo que apenas quatro das 20 crianças realizaram o teste GIN. Os limiares de gap do GC foram de 18,77±12,29 ms no RGDT e de 6,13±1,27 ms no teste GIN. A diferença entre os dois grupos foi estatisticamente significante. Além disso, houve diferença significativa na comparação dos resultados dos testes entre os sexos do GE, sendo o masculino melhor que o feminino. Não houve correlação entre a idade e os limiares de detecção de gap em ambos os grupos e, também, não houve significância entre o tempo de uso de IC e os resultados nos testes no GE. Mesmo avaliando a mesma habilidade auditiva, não houve correlação significante entre os resultados dos testes aplicados. Foi observado que crianças usuárias de IC apresentam os limiares de detecção de gap significativamente maiores que crianças sem alterações auditivas. / Auditory temporal resolution is considered one of the most important skills for acoustic signal processing along the time. It allows the identification of fine differences of speech segmental aspects, such as phonemes and the beginning and end of words in linked phrases. Children using a cochlear implant (CI) present specific characteristics of speech sign decoding and processing, along the time, performed by the CI. Thus, this research aimed at verifying the performance of children fitted with CIs, in temporal resolution tasks. The sample comprised 20 children using CI Nucleus 24/SPRINT (Experimental group - EG) and 20 children with no auditory alterations (Control Group - CG). The Random Gap Detection (RGDT) and Gaps In Noise (GIN) tests were applied to assess the temporal resolution skill through gap detection tests which were applied in free field and 40 dBSL. The statistical tests utilized for data analysis were Student´s t test, for independent data, Mann Whitney´s test and Pearson´s Correlation Coefficient. The children fitted with CIs achieved gap thresholds of 74,13±51 ms on the RGDT and 12,12±2,53 ms on the GIN test, the latter performed by only four out of the 20 children. Gap thresholds for the CG were 18,77±12,29 ms on the RGDT and 6,13±1,27 ms on the GIN test. The difference between the two groups was statistically significant. There was a significant difference in the comparison of the results of tests between the genders of EG, with males outdoing females. No correlation was seen between age and gap detection thresholds for both groups and there was no significance between the time of CI use and the results on the tests for the EG. Even assessing the same hearing skill, no significant correlation was seen between the results of the tests applied. Thus, it was observed that children fitted with cochlear implantation present gap detection thresholds significantly worse than those presented by normally hearing children.
175

Correlação da tensão no intermediário e as medidas de comprimento, altura e angulação de infraestruturas de próteses sobre implantes / Correlation of abutment tension and measures of length, height and angle of implant-supported prostheses framework

Piras, Fernanda Furtado 28 May 2015 (has links)
A adaptação passiva e estabilidade têm sido descritos como pré-requisitos importantes na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi estudar, com auxílio dos strain gauges, a deformação média gerada nos intermediários após a aplicação de carga axial em infraestruturas confeccionadas por três diferentes materiais. Além disso, através da microscopia confocal a laser, avaliar as medidas de comprimento, altura e angulação desses espécimes e mini pilares. Esses dados foram submetidos à análise estatística, a fim de encontrar possível correlação entre a deformação gerada e as medidas internas das infraestruturas com as externas dos intermediários em que foram parafusadas. Para essa investigação foi utilizado um modelo em poliuretano com dois implantes, hexágono externo, posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) fundição convencional em Ni-Cr; (U) usinada em zircônia por CAD/CAM e (S) sinterizada a laser em Co-Cr pelo CAD/CAM. Durante a aplicação de carga axial, as tensões geradas foram registradas por extensômetros unidos aos intermediários, e avaliadas quantitativamente e qualitativamente. De maneira geral, houve um predomínio de áreas de compressão, sendo que as poucas áreas de tração apresentaram baixos valores. O grupo sinterizado a laser foi o único que apresentou forças compressivas para todos os sensores. Os grupos usinado e convencional apresentaram comportamento semelhante, diferindo apenas em uma região. Posteriormente, as infraestruturas e os intermediários foram submetidos à microscopia confocal para avaliação de ângulo, comprimento e altura de suas paredes internas (infraestruturas) e externas (intermediários), nas regiões correspondentes à localização dos strain gauges. Para a angulação, todos os grupos mostraram valores semelhantes entre si e maiores que os dos mini pilares. Quanto ao comprimento e altura, todos valores foram diferentes entre si. Em relação aos mini pilares, os valores foram maiores na altura e menores no comprimento. Estes resultados foram analisados pelo método estatístico de Pearson o que levou à conclusão que, para algumas regiões dos medidores de tensão, há correlação entre deformação e comprimento, e também, deformação e ângulo. Quanto maior o ângulo, e quanto menor for o comprimento, maior a deformação mostrada. / The passive adaptation and stability have been described as important prerequisites in the choice of materials and manufacturing techniques in implant-supported prosthesis. The aim of this work was to study, with the aid of strain gauges, the average deformation generated in the abutment, after application of axial load on frameworks made up of three different materials. Besides, through confocal laser microscopy, assess the length, height, and angle of these specimens, and abutment. These data were statistically analyzed in order to find possible correlation between the deformation generated, and the internal measures of the framework and the external measure of the abutments they were screwed on. For this research, a model made of polyurethane with two external hexagon implants, positioned in the areas of teeth 43 and 45 was used. From this model, 12 three-element frameworks were fabricated and divided into 3 groups (n = 4), according to the technique used: (C) conventional Ni-Cr casting; (U) machined zirconia CAD / CAM and (S) laser sintered Co-Cr by CAD / CAM. During application of axial load, the tensions generated were recorded by strain gauges attached to the abutments, and evaluated quantitatively and qualitatively. In general, there was a predominance of compression areas, and the few areas of traction showed low values. The laser sintered group was the only one with compressive forces for all sensors. The milled and conventional groups behaved similarly, differing only in a region. Subsequently, the framework and the abutment were analyzed by confocal microscopy for evaluation of angle, length and height of the inner (framework) and outer (abutment) walls in regions corresponding to the location of strain gauges. For the variable angle, all groups showed similar values among themselves and greater than the abutments. As for the variables length and height, all values were different. Regarding the abutments, the values were higher in height and smaller in length. These results were analyzed by Pearson statistical method, leading to the conclusion that, for some regions, there was correlation between deformation and length, and also deformation and angle. The higher the angle and the smaller the length, the greater the deformation shown.
176

Características da deglutição em idosos submetidos a diferentes estratégias de reabilitação oral protética / Characteristics of swallowing in elderly individuals submitted to different strategies for prosthetic oral rehabilitation

Totta, Tatiane 29 August 2008 (has links)
O objetivo deste estudo foi verificar se diferentes estratégias de reabilitação oral protética acarretam modificações nos achados clínicos e videoendoscópicos da deglutição em idosos. Métodos: participaram da pesquisa 42 idosos saudáveis com desempenho cognitivo adequado (26 mulheres e 16 homens, 60-82 anos), desdentados totais ou parciais, separados em três grupos segundo avaliação odontológica prévia: próteses parciais fixas ou removíveis (PP) (n = 15); próteses totais removíveis superior e inferior (PTR) (n = 15); e próteses totais removíveis superior e próteses totais fixas implanto-suportadas inferior (PTFIS) (n = 12). O grupo controle foi constituído de 15 idosos dentados totais (DT) (6 homens e 9 mulheres, 60-80 anos) que atenderam aos critérios de inclusão na amostra. Avaliaram-se as consistências sólida (pão), pastosa (10 ml) e líquida (10 ml). Para a avaliação clínica propôs-se uma classificação da gravidade da disfunção da deglutição orofaríngea, distribuída em cinco níveis. Na avaliação instrumental, da qual participaram 37 idosos, realizou-se teste de sensibilidade laringofaríngea, e classificou-se a gravidade do distúrbio de deglutição, de acordo com a escala de comprometimento funcional (gravidade) da deglutição após a VED, ordenada em graus de 0 à III. Para a análise comparativa entre os grupos em ambas as avaliações, e para comparação entre os níveis de comprometimento da deglutição, utilizou-se o Teste de Kruskal-Wallis, adotando-se o nível de significância inferior a 5%. Resultados: Os achados clínicos e videoendoscópicos da deglutição demonstraram não haver diferenças estatisticamente significantes (p>0,05) entre os grupos estudados, nas três consistências ofertadas. Especificamente na avaliação clínica, para a consistência pastosa o grupo DT apresentou maior prevalência de deglutição funcional, enquanto a disfagia orofaríngea moderada foi o padrão de maior ocorrência no grupo PTR (p<0,01). Para o sólido, os grupos de reabilitação oral demonstraram predomínio das disfagias (p<0,01) em relação à deglutição normal e funcional, sendo predominante a disfagia orofaríngea moderada para o grupo PTR (p<0,01). A VED demonstrou, para todos os grupos, que na deglutição de líquido houve distribuição semelhante entre os níveis, enquanto nas consistências sólida e pastosa encontrou-se predomínio de disfagia (p<0,01), havendo maior ocorrência da disfagia orofaríngea moderada (p<0,01) para o grupo PTR na consistência pastosa. O teste de sensibilidade laringofaríngea demonstrou que 19 (51,35%) indivíduos apresentaram alteração da sensibilidade, sendo 6 (40%) do grupo PP, 7 (63,63%) do grupo PTR e 6 (54,54%) do grupo PTFIS. Conclusão: Idosos saudáveis podem apresentar diferentes níveis de deglutição, havendo maior ocorrência de disfagia orofaríngea para as consistências pastosa e sólida, sendo que diferentes estratégias de reabilitação oral não resultam em modificações no padrão de deglutição desses sujeitos. / This study investigated if different strategies of prosthetic oral rehabilitation cause changes in the clinical and videoendoscopic findings of swallowing in elderly individuals. Methods: The study was conducted on 42 healthy elderly subjects with adequate cognitive performance (26 women and 16 men, 60-82 years), completely or partially edentulous, divided in three groups according to the previous dental evaluation: wearing fixed or removable partial dentures (RPD) (n = 15); wearing maxillary and mandibular removable complete dentures (RCD) (n =15); and wearing maxillary removable complete dentures and mandibular implant-supported fixed complete dentures (ISFCD) (n = 12). The control group was composed of 15 completely dentate elderly individuals (DT) (6 men and 9 women, 60-80 years) who met the inclusion criteria. Solid (bread), paste (10 ml) and liquid (10 ml) food textures were analyzed. Clinical evaluation was performed by classification of the severity of dysfunction of oropharyngeal swallowing, divided in five scores. The instrumental evaluation was applied to 37 elderly individuals, comprising the laryngopharyngeal sensitivity test for classification of the severity of the swallowing disorder according to the scale of functional impairment (severity) of swallowing after the VED, divided in scores 0 to III. Comparison between groups in both evaluations and between the scores of impairment of swallowing was performed using the Kruskal-Wallis test, at a significance level below 5%. Results: The clinical and videoendoscopic findings of swallowing revealed no statistically significant differences (p>0.05) between the study groups, for the three textures. Specifically with regard to the clinical evaluation for the paste texture, the DT group exhibited higher prevalence of functional swallowing, while the RCD group presented higher occurrence of moderate oropharyngeal dysphagia (p<0.01). With regard to the solid texture, the groups of oral rehabilitation presented predominance of dysphagia (p<0.01) in relation to normal and functional swallowing, with predominance of moderate oropharyngeal dysphagia for the RCD group (p<0.01). The VED demonstrated, for all groups, that the swallowing of liquid had a similar distribution between scores, while for the solid and paste textures there was predominance of dysphagia (p<0.01), with higher occurrence of moderate oropharyngeal dysphagia (p<0.01) for the RCD group for the paste texture. The laryngopharyngeal sensitivity test demonstrated that 19 (51.35%) individuals presented alterations in sensitivity, being 6 (40%) in the RPD group, 7 (63.63%) in the RCD group and 6 (54.54%) in the ISFCD group. Conclusion: Healthy elderly individuals may present different scores of swallowing, with higher occurrence of oropharyngeal dysphagia for the paste and solid textures; different strategies of oral rehabilitation did not cause changes in the pattern of swallowing of these individuals.
177

Influência do \'biotipo periodontal\' na remodelação dos tecidos moles e da tábua óssea vestibular em alvéolos pós-exodontia e implantes imediatos, com e sem enxerto xenógeno / Influence of periodontal biotype on soft tissues and buccal boné plate remodeling in fresh extraction sockets and after immediate implant placement, with and without xenografts

Maia, Luciana Prado 04 April 2014 (has links)
Após exodontia e instalação de implantes imediatos o sítio edêntulo sofre uma substancial remodelação óssea. O objetivo do presente estudo foi avaliar a remodelação dos tecidos moles e da tábua óssea vestibular em alvéolos pósexodontia e em implantes imediatos em cães com um biotipo periodontal fino, com a associação de um material de enxerto. Oito cães tiveram a espessura da gengiva de um lado da mandíbula reduzida, os pré-molares mandibulares extraídos em cirurgia sem retalho e 4 implantes foram instalados de cada lado à 1,5 mm da tábua óssea vestibular. Os demais alvéolos foram utilizados para o estudo da dinâmica de cicatrização alveolar. Os sítios foram aleatoreamente alocados em: GT (grupo teste) = gengiva fina; GT + ME (GT com material de enxerto); GC (grupo controle) = gengiva normal; e GC + ME (GC com material de enxerto). Espessura da tábua óssea vestibular (ETOV), espessura de gengiva queratinizada (EGQ), largura alveolar (LA), altura de retração gengival (RG) e profundidade de sondagem (PS) foram avaliados clinicamente. Após 12 semanas os cães foram sacrificados e as amostras processadas para as análises de micro-tomografia computadorizada, histologia, histomorfometria, fluorescência e imunohistoquímica. Uma ETOV fina foi observada em todos os cães. Os procedimentos pré-cirúrgicos reduziram a EGQ nos grupos teste, com alterações mínimas na LA. Não houve diferenças estatísticas significantes entre os grupos para os parâmetros clínicos. Em todos os grupos o alvéolo ou o gap vestibular foram preenchidos por osso neoformado e uma leve reabsorção da tábua óssea vestibular foi observada, sem diferença estatística entre os grupos. Nos alvéolos pós-exodontia uma taxa de mineralização numericamente maior foi observada nos grupos que receberam material de enxerto em 12 semanas. A espessura do osso vestibular foi um fator fundamental na reabsorção da tábua óssea vestibular, mesmo com cirurgia sem retalho. Diminuir a gengiva para uma espessura crítica ou a adição de um biomaterial, em um biotipo fino pré-existente, não influenciou os resultados. / After tooth extraction and immediate implant placement the edentulous site undergo marked bone remodeling. The aim of the present study was to evaluate soft tissues and buccal bone remodeling in fresh extraction sockets and immediate implants in dogs with a thin periodontal biotype, with the association of a graft material. The gingiva of 8 dogs was thinned at one side of the mandible, mandibular premolars were extracted without flaps, and 4 implants were installed on each side at 1.5 mm from the buccal bone. The remaining sockets were used for the study of the alveolar healing dynamic. The sites were randomly assigned into: TG (test group) = thin gingiva; TG + GM (TG with grafting material); CG (control group) = normal gingiva; and CG + GM (CG with grafting material). Buccal bone thickness (BBT), thickness of keratinized tissue (TKT), alveolar width (AW), gingival recession height (GR) and probing depth (PD) were clinically evaluated. After 12 weeks the dogs were sacrificed and the samples were processed for microtomographic, histological, histomorphometric, fluorescence and immunohistochemistric analysis. A thin BBT was observed in all the dogs. The pre-surgical procedures reduced gingival thickness in the test groups, with minimal changes of the AW. There were no statistically significant differences among the groups for the clinical parameters. In all the groups the socket or the buccal gap was filled with newly formed bone and a slight buccal bone loss was observed, with no statistical difference among the groups. In the extraction sockets a numerically higher mineralization rate was observed for the grafted groups at 12 weeks. The thickness of the buccal bone was a fundamental factor on buccal bone plate resorption, even with a flapless approach. To reduce the gingival thickness or the addition of a biomaterial, in a thin biotype, did not influence the results.
178

"Análise comparativa entre sistemas de retenção para próteses auriculares implanto-retidas" / Comparative analyses between retentive systems for implant-retained ear prosthesis

Sousa, Andréa Alves de 03 May 2006 (has links)
As próteses auriculares retidas por meio de implantes osseointegráveis proporcionam maior segurança e conforto, melhorando a qualidade de vida dos pacientes. Este trabalho avalia comparativamente a força de resistência à tração dos sistemas de retenção barra/2 clipes, barra/3 clipes, 2 magnetos, e 3 magnetos, empregados para retenção de prótese auricular. Os sistemas de retenção foram submetidos à ciclagem mecânica, com intervalos de 540 ciclos de inserção e remoção para a simulação de períodos de uso clínico, até um total de 3240 ciclos, sendo, a cada intervalo, submetidos ao ensaio mecânico para força de resistência à tração. Os resultados indicam que os sistemas barra/clipes proporcionam maiores retenções do que os sistemas com magnetos e ao mesmo tempo em que a ciclagem mecânica não interfere na relação entre o número de elementos retentores e a retenção proporcionada dentro dos sistemas barra/clip e dos sistemas magnetos. O sistema barra/2 clipes sofre uma perda significantemente maior da capacidade de retenção frente à ciclagem mecânica, sugerindo uma menor longevidade clínica. A relação da capacidade de retenção entre os sistemas não se altera com a ciclagem mecânica uma vez que, a retenção proporcionada pelo sistema barra/3 clipes mantém-se superior, indicando uma maior durabilidade clínica. As retenções proporcionadas pelos sistemas barra/2 clipes e 3 magnetos, bem como aquelas proporcionadas pelos sistemas 2 e 3 magnetos não diferem ao final da ciclagem mecânica, indicando uma durabilidade clínica semelhante. / Placement of osseointegrated implants for retention of ear prosthesis provides greater security and comfort, improving the quality of life of the patients. This work evaluates and compares the retentive mechanical behavior of bar/2 clips, bar/3 clips, 2 magnets, and 3 magnets retention systems, used for implant-retained ear prosthesis. The systems were submitted to mechanical cycling , with intervals of 540 cycles of insertion and removal, for the simulation of clinical periods of function, up to 3240 cycles, being submitted to the mechanical forces essay at each interval. Data were subjected to Tukey-Kramer procedure and the comparative analyses indicate that the bar/clips systems provide different and better retentive forces than the magnet systems and mechanical cycling does not alter the numerical relative performance of the retainer components within the bar/clip or magnet retention system. The bar/2 clips system shows the biggest and statistically significant loss of the retentive forces during mechanical cycling (p<0,05), suggesting a shorter clinical life. The retention provided by the bar/3 clips system remains superior after mechanical cycling, indicating a longer clinical life. The relation between the retention forces presented within the bar/clip systems and magnets systems does change under mechanical cycling. Also, the relation between the bar/2 clips system and 3 magnets system, as well as between 2 and 3 magnets systems do not differ at the end of mechanical cycling , indicating a similar behavior toward clinical life.
179

Avaliação da relação entre o desajuste vertical em interfaces pilar/cilindro protético fundido e sobrefundido e a perda de torque de parafusos protéticos de titânio / Evaluation of the relationship between vertical misfit in abutment / casting and pre-machined prosthetic cylinder joint and loosening of prosthetic titanium screws

Falcão Filho, Hilmo Barreto Leite 15 December 2005 (has links)
Este estudo foi desenvolvido com o objetivo de avaliar os níveis de desajustes em interfaces pilar / cilindros protéticos obtidos a partir de cilindros calcináveis e pré-usinados fundidos em duas diferentes ligas metálicas, e a perda de torque em parafusos protéticos de titânio utilizados para fixar estas interfaces, analisando a relação entre estas variáveis. Os parafusos protéticos foram submetidos a análises de microscopia eletrônica de varredura antes e após o aperto. Os valores de torque foram aferidos por um torquímetro digital, os valores de desajustes registrados por um microscópio óptico e foram registradas imagens dos corpos-de-prova por uma câmera digital acoplada a outro microscópio óptico. Todos os valores de desajustes e perda de torque foram submetidos a testes de freqüência e analisados pelos testes T e Mann-Whitney para comparação entre os grupos, e pelo teste Spearman para a verificação da correlação entre as variáveis. Os resultados evidenciaram diferenças estatisticamente significantes (p &#8804; 0,05) para os diferentes tipos de cilindros utilizados quanto ao desajuste (p = 0,000), e não foram evidenciadas diferenças estatísticas significantes (p &#8804; 0,05) entre os cilindros quanto à perda de torque (p = 0,052) nem entre as diferentes ligas quanto ao desajuste (p = 0,615) e perda de torque (p = 0,811). A análise estatística confirmou a correlação (p &#8804; 0,05) entre as variáveis desajuste e perda do torque (p = 0,017). Foram verificadas alterações nas superfícies das roscas dos parafusos após o torque e defeitos de fundição em alguns cilindros protéticos, especialmente nos cilindros fundidos a partir de cilindros calcináveis. De acordo com os resultados, a metodologia empregada e as limitações deste estudo, concluiu-se que os cilindros pré-usinados proporcionam níveis de desajustes mais favoráveis do que os cilindros calcináveis, existe correlação entre os desajustes nas interfaces pilar / cilindro protético e perda de torque nos parafusos de titânio, e defeitos de fundição podem influenciar nos desajustes. / This study was developed with the objective to evaluate the levels of misfit in abutment / coping joint obtained from casting and pre-machined copings in two different alloys and the torque loosening in prosthetic titanium screws used to connect this joint, analyzing the relation between the two variable. The prosthetic screws were submitted to analyses on scanning electron microscopy before and after the torque. The values of torque were checked by one digital torque meter, the values of misfits were registered by an optic microscope and images of the samples were registered by an digital camera connected to another optic microscope. All the values of misfits and torque loosening was submitted to frequency tests and analyzed by the T and Mann-Whitney tests for the comparison between the groups, and by the Spearman test for the verification of the correlation between the two variable. The results had evidenced significant statistical differences (p &#8804; 0,05) for the different types of copings used about misfit (p = 0,000), and had not been evidenced significant statistical differences (p &#8804; 0,05) between the copings about the torque loosening (p = 0,052), neither for the different alloys about misfit (p = 0,615) and torque loosening (p = 0,811). The statistical Spearman test analysis confirmed the correlation between the misfit and torque loosening (p = 0,017). It was verified alterations in the surfaces of the threads of the screws after the torque and casting defects in some prosthetic cylinders, especially in the casting cylinders. In accordance with the results, the employed methodology and the limitations of this study, it has been concluded that the pre-machined copings provide more favorable levels of misfits than the casting copings, there is correlation between misfits in the abutment / coping joints and torque loosening in the titanium screws, and casting defects should influence in the misfits.
180

Microtopografia de implantes de titânio com diferentes tratamentos de superfícies à microscopia eletrônica de varredura e de força atômica / Microtopography of titanium implants with different surface treatments scanning in electronic microscopy and atomic force microscopy

Moretti, Lívia Alves Corrêa 31 August 2012 (has links)
INTRODUÇÃO: A qualidade da interface osso-implante pode ser influenciada diretamente pela rugosidade da superfície e determina a forma como as células interagem, aderem-se e fixam-se a ela, podendo potencializar e encurtar o tempo de osseointegração. Este estudo propôs-se analisar qualitativamente a topografia e arquitetura de diferentes superfícies de implantes dentários, compará-las, descrevê-las e correlacioná-las com os possíveis eventos moleculares e celulares iniciais da osseointegração. MATERIAIS E MÉTODOS: cinco implantes com diferentes tratamentos de superfície foram analisados em três diferentes áreas: apical, região de roscas (topos, flancos e vales) e região cervical por microscopia eletrônica de varredura (MEV) e topo do ápice em microscopia de força atômica (MFA). RESULTADOS: as superfícies dos implantes NanoTite®, SLA® e Xive® TG plus, no MEV, são semelhantes pelo seu aspecto de lacunas, diferindo no plano superficial; a superfície do implantes TiUnite® apresenta características coraliformes/vulcanoides, enquanto a do implante Exopro® apresenta estrias em formas de pequenos sulcos. A rugosidade média (Ra) à MFA, apresentou-se maior no implante TiUnite®, seguido pelos implantes Xive®TG plus, NanoTite®, Exopro® e SLA®. A área analisada se restringe a pequenos pontos (nanométricos), que não possibilita uma visão panorâmica de todas as estruturas (micrométricas), e consequentemente não permite uma real comparação da rugosidade. CONCLUSÕES: a metodologia ideal para análise das superfícies com o objetivo de compreender como as células às colonizam e se aderem deve ser em escala micrométrica, destacando-se à MEV em detrimento da MFA. As duas metodologias, MEV e MFA, são fundamentais na análise de superfície de implantes dentários, porém devem ser conjuntamente e/ou simultaneamente empregadas. A MFA parece ser a mais adequada para estudos que visem a interação da superfície dos implantes com estrutura de nível molecular e à MEV, no nível celular. Cada tratamento de superfície promove um tipo específico de topografia, cujos benefícios moleculares, teciduais e clínicos devem ser estudados caso a caso. / Introduction: Bone-implant interface quality may be influenced by surface roughness and determines how cells interact, cling to and fix to, therefore can enhance and shorten the time for osseointegration. This study aims to analyze qualitatively the topography and architecture of different dental implants surfaces, to compare and describe them. MATERIALS AND METHODS: five implants with different surface treatments were evaluated in three different areas: apical, region of threads (tops, sides and valleys) and cervical region by scanning electron microscopy (SEM) and atomic force microscopy (AFM), correlating the possible molecular and cellular initials events of osseointegration. RESULTS: the surfaces of the implants NanoTite®, SLA® and ® Xive® TG plus, in the SEM, are similar by their appearance of gaps, although they differ in surface plane; the surface of TiUnite® implants have features such as corals and/or volcanos, while the implant Exopro ® has stretch marks in form of small grooves. The average roughness (Ra) to the AFM, appeared higher in TiUnite ® implant, followed by Xive® TG plus NanoTite®, Exopro® and SLA® implants. The area analyzed in the AFM, is restricted to small points (nanometrics), and do not allow denote a panoramic view of all structures (micrometrics), not allowing a real comparison of surface roughness. CONCLUSIONS: the optimal methodology for surfaces analysis with the objective of understanding how the cells colonize and fix to dental implants should be in the micrometer scale, highlighting the SEM over AFM. The AFM seems to be most suitable for studies aiming the interaction of the implant surface with molecular-level and SEM at the cellular level. Each treatment promotes a specific surface topography whose benefits molecular, tissue, and clinical should be studied separately.

Page generated in 0.0553 seconds