• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 67
  • 3
  • 3
  • 3
  • 3
  • 3
  • Tagged with
  • 67
  • 67
  • 64
  • 33
  • 25
  • 21
  • 19
  • 18
  • 18
  • 18
  • 15
  • 15
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas

Delben, Juliana Aparecida [UNESP] 23 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-23Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 delben_ja_me_araca.pdf: 1525895 bytes, checksum: 08b0efeaeab10edf292abba40231b759 (MD5) / A longevidade das próteses e implantes é dependente da adequada adaptação entre os componentes bem como da distribuição favorável de forças às estruturas de suporte. O afrouxamento do parafuso de retenção é uma falha mecânica comumente observada devido à redução da pré-carga gerada no parafuso de retenção, responsável pela manutenção da estabilidade da união parafusada e resistência às forças que tendem a separar os componentes. O objetivo do estudo foi avaliar a influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas, submetidos a sucessivos reapertos e ciclagem mecânica. Foram confeccionadas 60 coroas de acordo com os grupos de estudo (n=12): Grupo I - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metalocerâmicas, Grupo II - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metaloplásticas, Grupo III – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metalocerâmicas, Grupo IV – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metaloplásticas, Grupo IV - pilares de zircônia obtidos pelo sistema CAD/CAM (computer-aided design/computer-aided manufacturing) para obtenção de coroas cerâmicas. As coroas foram unidas a implantes de hexágono externo por meio de parafuso de retenção quadrado de ouro com torque de inserção de 35 Ncm e submetidas à ciclagem mecânica com aplicação de carregamento vertical dinâmico de 50N a uma freqüência de 2Hz. Valores de destorque foram mensurados antes da ciclagem mecânica e após cada período de 1x105 ciclos seguido de reaperto com 35 Ncm de modo a completar 1x106 ciclos. Mensurações da desadaptação vertical na interface pilar-implante foram realizadas através de estereomicroscopia inicialmente e ao final da... / The longevity of prostheses and implants depends on fit betweenn components as well as adequate forces distribution to supporting structures. Retaining screw loosening is a commom mechanical complication due to preload reduction that provides joint stability and resistance to separating forces. The aim of this study was to evaluate the influence of different abutments and veneering materials on preload maintenance of retaining screw of implant-supported crowns submitted to repeated tightening and mechanical cycling. Sixty crowns were obtained according to the groups (n=12): Group I – Gold UCLA abutment cast in gold allow with ceramic vennering, Group II – Gold UCLA abutment cast in gold alloy with resin veneering, Group III – UCLA abutment cast in titanium with ceramic veneering, Group IV – UCLA abutment cast in titanium with resin veneering, and Group V – zirconia abutment obtained by CAD/CAM (computer-aided desing/computer-aided manufacturing) system with ceramic veneering. The crowns were attached to external hexagon implants by gold retaining screws with insertion torque of 35Ncm. The replicas were submitted to mechanical cycling with vertical dinamic loading of 50N at 2Hz. Detorque measurements were performed initially and after each period of 1x105 cycles followed by retightening of retaining screw with 35Ncm until 1x106 cycles. Measurements of vertical misfit on abutment-implant interface were performed through estereomicroscopy initially and after mechanical cycling. Data were submitted to analysis of variance, Fisher’s exact test, paired t test, Student’s t-test and Pearson correlation (P<.05). All detorque measurements were lower than insertion torque of 35Ncm. There was statistically significant difference among the 5 groups (P<.05) for detorque values obtained initially and after mechanical cycling. However, there was no statistically significant difference... (Complete abstract click electronic access below)
22

Desenvolvimento e fabricação de um protótipo de implante odontológico a partir de osso bovino como material de preenchimento em cirurgias de levantamento de seio maxilar

Stares, Steferson Luiz January 2006 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Engenharia Mecânica / Made available in DSpace on 2012-10-22T15:57:49Z (GMT). No. of bitstreams: 1 228760.pdf: 5650800 bytes, checksum: a28c8ed686cd495bcf66e3a07d363ff0 (MD5) / O presente estudo tem como objetivo o desenvolvimento de um implante (parafuso+porca) manufaturado por usinagem e tendo como matéria-prima osso cortical bovino mineral desproteinizado (OBMD). O implante foi desenvolvido para futuro uso clínico em substituição a enxertos ósseos nas técnicas de levantamento de seio maxilar. Avaliou-se também as possíveis alterações nas propriedades do OBMD, tanto em estado desengordurado (G1) como esterilizado (G2), através de ensaios mecânicos para medir o poder de fixação dos parafusos. Cães fêmeas da raça Bangor Beagle foram utilizados neste experimento. Por meio de um acesso cirúrgico, a tíbia foi exposta e nela foram usinadas com orientação diagonal em relação ao eixo longitudinal do osso, cinco roscas internas passantes. Os implantes esterilizados foram inseridos totalmente no osso. Após um período de observação de 120 dias, os implantes foram removidos, processados e avaliados histologicamente. Análises histológicas demonstraram evidente neo-formação de tecido ósseo à interface osso-implante. Nos ensaios mecânicos e análise estatística entre os grupos G1 e G2 investigados foram observadas diferenças significativas (p<< 0,05).
23

Análise comparativa da topografia e presença de impurezas de implantes dentais com superfície texturizada por meio de microscopia eletrônica de varredura (MEV)

Castro, Kavio Narciso de Oliveira January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-21T13:08:28Z (GMT). No. of bitstreams: 1 203835.pdf: 10797340 bytes, checksum: bfd0a2cbac605c338cdfb3cadf47f950 (MD5) / O objetivo desta análise comparativa foi observar qualitativamente, por meio de Microscopia Eletrônica de Varredura (MEV), as variações microscópicas topográficas e a presença de impurezas em cinco fabricantes de implantes osteointegráveis submetidos a diferentes processos de texturização: Conexão (Grupo 1); 3i (Grupo 2); Neodent (Grupo 3); SIN (Grupo 4); Titanium fix (Grupo 5). De acordo com os resultados foi possível concluir que, no aspecto topográfico os fabricantes SIN (G4) e 3i (G2) foram estatisticamente equivalentes, em um nível de significância de 1% e melhores que todos os demais, exibindo uma característica topográfica desejável. Os fabricantes Conexão (G1), Neodent (G3) e Titanium fix (G5) mostraram diferenças significantes entre si, em um nível de significância de 1% e padrões de texturização variáveis. No aspecto presença de impurezas os fabricantes Neodent (G3) e Conexão (G1) foram equivalentes entre si, em um nível de significância de 1% e melhores que todos os demais, mostrando superfícies mais livres de impurezas que todos os demais. Os fabricantes SIN (G4) e 3i (G2) foram equivalentes entre si, em um nível de significância de 1%, exibindo superfícies com uma certa quantidade de impurezas e melhores que o fabricante Titanium fix, que se mostrou inferior a todos os demais, exibindo superfícies com grande quantidade de impurezas.
24

Proposta protocolar para avaliar in vitro o crescimento e adesão celulares frente a implantes de titânio c.p. com quatro texturas superficiais obtidas por usinagem

Makowiecky, Edson January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T15:29:55Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:57:59Z : No. of bitstreams: 1 182038.pdf: 8962650 bytes, checksum: 18471b0f80e7a5054554eaf43450f159 (MD5) / A biocompatibilidade promove a oportunidade de investigar e comparar os resultados fenomenológicos gerados pelos estudos laboratoriais in vitro, investigações in vivo, em animais e, em humanos. Este trabalho situa-se entre estudos que visam beneficiar processos de osseointegração, fundamentais no desenvolvimento dos implantes, por meio de estudos in vitro. Trata-se da proposta de um protocolo para avaliar in vitro, em culturas de células osteoprogenitoras e células osteoblásticas provenientes de maxilares humanos, o crescimento e adesão celulares frente à quatro diferentes rugosidades obtidas por usinagem na superfície de amostras de cilindro de titânio c.p. seccionados.
25

Regeneração óssea vertical usando barreira não-porosa de politetrafluoretileno em implantes osteointegrados inseridos parcialmente na tíbia de coelhos

Macedo, Nelson Luiz de [UNESP] 11 June 1999 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:24:48Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-11. Added 1 bitstream(s) on 2015-12-10T14:30:56Z : No. of bitstreams: 1 000135628.pdf: 4737621 bytes, checksum: 65372fad0f2424a027b424684796f0c6 (MD5) / O objetivo deste estudo foi avaliar a possibilidade de obter regeneração óssea dirigida utilizando-se uma barreira fisica não-porosa de PTFE em implantes osteointegrados, parcialmente inseridos na tíbia de coelhos, e as característícas da interface entre implantes de titânio, revestidos ou não com plasma de titânio, e o tecido ósseo regenerado. Vinte implantes Screw-Vent foram instalados nas tíbias direita e esquerda, emergindo 3,0 mm do topo da crista óssea, criando um defeito ósseo horizontal. No lado experimental, os implantes e o tecido ósseo adjacente foram cobertos com uma barreira não-porosa de PTFE. A análise histológica mostrou que todos os implantes estavam em contato direto com o tecido ósseo. As medidas histológicas mostraram um ganho ósseo médio em altura de 2,15 mm e 2,42 mm nos defeitos com barreira, e de 1,95 mm e 0,43 mm nos controles com revestimento de plasma de titânio e com tratamento ácido da superficie, respectivamente. Os resultados sugeriram que a colocação de implantes emergindo 3,0 mm do defeito ósseo pode resultar em crescimento ósseo vertical e que o osso regenerado foi capaz de osteointegrar os implantes. A utilização da barreira parece ser crítica quando se utiliza o implante de titânio com a superficie tratada por ácido / The purpose of this study was to evaluate the possibility to obtaining guided bone regeneration utilizing a nonporous PTFE barrier in the osseointegrated implants, protruding from the bone level of the rabbit tíbia. The histologic characteristics of the interface between titanium implants, one group titanium-plasma coated, another group with acid-treated surfaces and the regenerated bone were also studied Twenty Screw-Vent implants were placed in tibias of five rabbits, two at the right side and two at the left side, protruding 3 mm from the bone level, to create a horizontal bone defect. ln the experimental side, the implants and adjacent bone were protected with a nonporous PTFE barrier. Histologic analysis after three months showed that all implants were in direct contact with the bane. Histologic measurements showed an average gain in bone height of the 2.15 and 2.42 mm for the barrier group and 1.95 and 0.43 mm for the control defects, in the titanium plasma-spray and acid-treated implant surfaces, respectively. The results suggest that the placement of implants protruding 3 mm from crestal bone defects may result in vertical bone augmentation and the regenerated bone is able to osseointegrate implants. lt seems to be critical the use of the PTFE barrier when acid-treated surface implants are inserted
26

Avaliação do reparo ósseo de cavidades preenchidas por vidro bioativo ou osso liofilizado desmineralizado: análises biomecânica, microscópica e histométrica em cães

Mendes, Vanessa Cristina [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:41:42Z : No. of bitstreams: 1 mendes_vc_dr_araca.pdf: 2490243 bytes, checksum: 6ce7b53f4434b723ec9c25c37375666f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos do presente estudo foram analisar e comparar, em cães, a reparação óssea em defeitos preenchidos com vidro bioativo e osso desmineralizado liofilizado e comparar com áreas que não receberam biomateriais, antes e após a inserção de implantes dentários de titânio. Cavidades com 6mm de diâmetro foram realizadas em ambos os úmeros de 6 cães machos saudáveis e preenchidas com vidro bioativo, osso liofilizado desmineralizado e coágulo. Após 5 meses de reparação, foi removido tecido ósseo do centro das cavidades para análise de microscopia óptica. A seguir, implantes dentários de titânio foram colocados no centro dessas cavidades e em áreas de osso pré-existente. Três meses depois, realizou-se o teste biomecânico de contra-torque dos implantes. Os cães foram sacrificados e o tecido ósseo encaminhado para processamento e análise de microscopia eletrônica por retroespalhamento de elétrons. No teste biomecânico não foram observadas diferenças estatisticamente significantes entre os 4 grupos. A análise de microscopia óptica demonstrou a presença de ambos os biomateriais e tecido ósseo neoformado na maioria das amostras do grupo experimental. Na microscopia eletrônica por retro-espalhamento de elétrons observou-se neoformação óssea em todos os grupos. Pela análise histométrica, a quantidade de neoformação óssea no grupo do vidro bioativo foi estatisticamente maior em relação aos outros grupos. Concluiu-se que o vidro bioativo apresentou os melhores resultados em porcentagem de neoformação óssea. No entanto, uma reparação satisfatória foi demonstrada em todos os grupos, com adequada qualidade óssea ao redor dos implantes dentários. / The objectives of the present study were to analyze and compare, in dogs, the bone healing in large areas grafted with bioactive glass and DFDBA to areas without any grafting, before and after the insertion of titanium dental implants. Cavities (6mm diameter) were drilled in both humeri of 6 healthy male dogs. The cavities were filled in with bioactive glass, DFDBA and clot. After 5 months, bone was removed from the centre of the cavities and processed for light microscopy analysis. Titanium dental implants were placed in these sites and in areas not previously drilled. Three months later, a biomechanical test was performed and the force necessary to unscrew the titanium implants was measured. Dogs were sacrificed and the bone removed. After embedding in PMMA, calcified samples were cut in half and polished for back-scattering SEM analysis. No statistically significant differences were observed among the 4 groups concerning the biomechanical test, according to the test U of Mann- Whitney. Light microscopy analysis showed the presence of both biomaterials among the regenerated bone. In the back-scattering analysis, regenerated bone was seen in all groups, and DFDBA presented the least volume. Remnants of granules of bioactive glass were still present, but in a smaller size. Because granules of DFDBA have the same image density of bone, if present, they couldn’t be identified. According to the test U of Mann-Whitney, the amount of bone formation in the bioactive glass group was statistically higher compared to the other groups. Based on the findings of this study, it was concluded that the bioactive glass showed best results in terms of bone volume. However, a satisfactory regeneration of bone in large defects with adequate bone quality was observed around dental implants in all groups.
27

Implantes osseointegráveis instalados sobre raízes reimplantadas tardiamente

Cardoso, Leandro de Carvalho [UNESP] 05 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-05Bitstream added on 2014-06-13T21:02:13Z : No. of bitstreams: 1 cardoso_lc_dr_araca.pdf: 1917765 bytes, checksum: a068b0645b4f20057a8f729027757d38 (MD5) / O objetivo deste trabalho foi analisar o reparo ósseo peri-implantar de implantes instalados sobre raízes dentárias reimplantadas tardiamente, apresentando processo de anquilose e reabsorção por substituição. Foram utilizados os terceiros e quartos pré-molares inferiores de 4 cães machos (Beagle). Os dentes foram seccionados, e as raízes mesiais extraídas e mantidas durante 1 hora em temperatura ambiente. Após a remoção do ligamento periodontal necrótico e tratamento endodôntico, imergiram-se em fluoreto de sódio por 5 minutos e reimplantou a porção no alvéolo esplintando nas porções distais. Nestas foram realizadas pulpotomia e restauração. Decorridos 30 dias, as porções mesiais tiveram suas coroas seccionadas. Após 5 meses, cinco implantes foram instalados em osso reparado, grupo I, (Controle); nove foram instalados nos alvéolos frescos pós-exodônticos das porções distais (Grupo II – Imediato) e doze implantes foram instalados sobre as raízes mesiais em processo de reabsorção radicular externa (Grupo III – experimental). Decorridos 120 dias, os resultados foram analisados pelo contato osso implante da superfície do implante sem roscas e das três primeiras roscas. Foi avaliada, também, a área de tecido ósseo presente nos espaços internos das três primeiras roscas e da área espelho correspondente. O contato osso implante foi de 55% no grupo controle, 48% no imediato e 40% no grupo experimental. A área de tecido ósseo foi, respectivamente, 71%, 61% e 55%, e a área espelho de tecido ósseo foi de 62%, 60% e 58%. Conclui-se que o reparo ósseo perimplantar de implantes instalados sobre raízes apresentou um pequeno em relação aos outros dois grupos. / The purpose of this study was to analyze the peri-implant bone repair of dental implants placed on delayed reimplated roots, with process of ankylosis and reabsorption by substitution. The lower third and fourth pre-molar of four male dogs (Beagle) was used. The teeth were cut, and the mesial roots were extracted and kept out for 1 hour at ambient temperature. After removal of necrotic periodontal ligament and endodontic treatment, the root was immersed in sodium fluoride for 5 minutes. Then it was reimplanted in the correspondent alveolar bone and splinted in distal portion. A pulpotomy and a crown restoration were conducted on the distal portion. After 30 days, the mesial portions had their crowns cut (decoronation).Moreover, 5 months later, five implants were installed in bone repair, Group I (Control), and nine were installed in the fresh socket of the distal portions, which were extracted (Group II - Immediate). Finally, twelve implants were installed on the mesial roots, with process of external resorption (Group III - experimental). After 120 days, the results were analyzed by bone implant contact, from the surface of the implant without threads to the first three threads. It was also evaluated the area of the bone tissue located in the internal spaces of the first three threads and the corresponding mirror area. The bone implant contact was 55% in the control group, 48% in the immediate group and 40% in the experimental group. The area of bone tissue in the internal threads area was respectively 71%, 61% and 55%, and the mirror area of bone tissue had the following results: 62%, 60% and 58%. It was concluded that peri-implant bone repair of the implant put on the roots with an external resorption showed delay compared to the other two groups.
28

Avaliação da osseointegração promovida por implantes jateados por Al2O3: análises histológica e histométrica em cães

Ponzoni, Daniela [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:41:00Z : No. of bitstreams: 1 ponzoni_d_dr_araca.pdf: 781446 bytes, checksum: 6716157527edd6e5ca653e94715b65fd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A formação de uma interface osseointegrada é mais previsível quando osso denso e saudável está em contato com a superfície do implante no momento da instalação. Porém, a colocação de implantes imediatos após exodontia apresenta inúmeras vantagens, entre elas a preservação da arquitetura óssea e gengival dos processos alveolares, além da diminuição do tempo cirúrgico. A utilização de uma superfície modificada proporciona um maior contato ósseo com o implante; baseado em princípios biológicos. A proposta deste trabalho é avaliar qualitativa e quantitativamente a interface entre osso e os implantes de titânio, jateados por Al2O3 instalados imediatamente após exodontias, em cães. Os implantes foram instalados nos alvéolos de pré-molares mandibulares bilateralmente em quatro cães. Foram instalados quatro implantes para cada animal (4mm de diâmetro e 10mm de comprimento) do Sistema Colosso (Emfils®), sendo dois de cada lado da mandíbula. Os animais foram sacrificados aos 120 dias pós-operatórios. As peças foram desmineralizadas, e os implantes removidos. Três implantes foram perdidos, três fibrointegrados e dez osseointegrados. A análise quantitativa foi realizada considerando-se cinco roscas apicais e o fundo do implante. A análise histológica mostrou tecido ósseo saudável em fase de maturação em íntimo contato com os implantes osseointegrados. Na análise histométrica, observou-se um contato ósseo de 76% nos implantes osseointegrados. / An osseointegrated interface could be predictable when dense and healthy bone is in contact with the titanium implant surface at the moment of implant insertion. However, immediate implantation after exodontia presents numerous advantages, among them, maintenance of bone and gingival architecture and decrease of operative time. The use of an implant with modified surface favors bone contact, according to biological principles. This study aims to evaluate the interface between bone and Al2O3 blasted titanium implants installed in 4 dogs immediately after bilateral exodontias of mandibular premolars. Four Emfils® implants (Sistema Colosso - 4mm diameter; 10mm length), 2 per side, were used in each dog. Animals were sacrificed after 120 days of surgery and the samples removed. Bone was decalcified and the implants removed. Three implants were lost, 3 had fibrointegration and 10 osseointegrated. Histological analysis showed a healthy tissue in process of maturation interfacing osseointegrated implants. Quantitative analysis was focused in 5 apical threads and the bottom of the implants. It was shown a contact of 76% between bone and the implants. Osseointegration was achieved around Al2O3 blasted titanium implants installed immediately after exodontias.
29

Enxerto autógeno para aumento em espessura e ou altura do processo ósseo alveolar, transtornos de técnica cirúrgica, complicações e sobrevivência dos implantes

Moraes Júnior, Edgard Franco [UNESP] January 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2002Bitstream added on 2014-06-13T20:21:54Z : No. of bitstreams: 1 moraesjunior_ef_dr_araca.pdf: 1027137 bytes, checksum: 69155df278e66cc86de2444a36139fb6 (MD5) / Foi realizado um estudo retrospectivo para avaliar os resultados da reconstrução do processo alveolar intensamente reabsorvido com diferentes tipos de enxerto ósseo autógeno associados à instalação de implantes simultâneos e mediatos (após 4 meses da instalação do enxerto) realizados no período de 4 anos e 6 meses. Foram selecionados para este estudo 84 pacientes, submetidos à reconstrução de defeitos ósseos dos maxilares, com enxertos ósseos do mento, linha oblíqua da mandíbula, crista ilíaca anterior e calota craniana, com um total de 346 implantes instalados, sendo que, 257 destes implantes encontravam-se, com as próteses implantossuportadas instaladas, e distribuídos em 40 implantes simultâneos e 217 mediatos. Desta forma, foram avaliadas os transtornos de técnica cirúrgica e as complicações relacionadas com as áreas receptoras, bem como a taxa de sobrevivência dos implantes. De acordo com os resultados obtidos, dentre alguns dos transtornos de técnica cirúrgica e complicações estavam a redução da quantidade de mucosa ceratinizada na cortical vestibular e conseqüente perda da profundidade de sulco, assim como, exposição parcial do enxerto, contaminação do enxerto, entre outras complicações verificadas. A taxa de sobrevivência, obtida para os implantes simultâneos e mediatos instalados, foi de 94,55%. Quando a taxa de sobrevivência foi avaliada individualmente para cada grupo, no caso dos implantes simultâneos foi encontrado um resultado de 97,50%, enquanto que para os implantes mediatos obteve-se um resultado de 94,10%%. Portanto com este estudo, conclui-se que dos transtornos de técnica cirúrgica com maior ocorrência estava a redução da quantidade de mucosa ceratinizada sobre a crista do rebordo, complicações como exposição parcial do enxerto entre outras, que as áreas doadoras intrabucais oferecem vantagem... / A retrospective study was carried out in order to evaluate the outcomes of the reconstruction of the severely resorbed alveolar ridge through different types of autogenous bone grafts associated to the placement of simultaneous and delayed implants (4 months after the bone graft procedure) accomplished during a period of 4 years and 6 months. A total of 84 patients were selected for the present study, which were submitted to reconstruction of the bone defects of the jaws by means of bone grafts from the chin, external oblique ridge, anterior iliac crest, cranial vault, adding up to 346 implants, from which 257 (40 simultaneous and 217 delayed implants), with the installed implant-supported prostheses. The evaluation concerned of the overturn of surgical technique and complications related to the receptor sites, as well as the survival rate of the implants. The results indicated occurrence of the overturn of surgical technique and complications such as reduction in the amount of keratinized mucosa over the buccal cortical plate with consequent decrease in vestibular depth, as well as partial exposure of the graft, contamination of the graft, and others. The survival rate for both simultaneous and delayed implants was 94.55%. Regarding the individual evaluation of each group, the simultaneous implants demonstrated a survival rate of 97.50% in relation to 94.10% for the delayed implants. The most frequent of the overturn of surgical technique were reduction in the amount of keratinized mucosa over the alveolar ridge, complications as partial exhibition of the graft among others, better performance of the intraoral donor sites in relation to the extraoral sites, positive association between implant failures and iliac crest grafts, besides significantly worse outcomes for the female subjects in relation to the males. Better results were observed for the simultaneous implants, what is in disagreement with previous studies.
30

Análises biomecânica e histológica da interface de implantes osseointegrados submetidos à carga mastigatória imediata em mandíbulas de cães

Lenharo, Ariel [UNESP] 03 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-03Bitstream added on 2014-06-13T19:22:06Z : No. of bitstreams: 1 lenharo_a_dr_araca_prot.pdf: 1956702 bytes, checksum: 5122f32b3aab14c8107085fded1a11c7 (MD5) / O objetivo deste trabalho foi de estudar em mandíbula de cães, os implantes osseointegrados submetidos a carga imediata considerando a qualidade óssea formada na interface implante-osso, como também medir o contato ósseo da referida interface. Foram utilizados quatro cães que, após as exodontias, receberam três implantes Osseotite 3,75 x 8,5 (Implant Innovations Incorporation) e, após os procedimentos de moldagem e de laboratório para a confecção da prótese em Níquel-Cromo, estas foram instaladas no mesmo dia da instalação dos implantes e submetidas a técnica da carga imediata. Após 240 dias, os implantes mesial e distal foram contra-torqueados medindo-se a resistência do tecido ósseo neoformado. Na seqüência, os animais foram sacrificados (240 dias) e as peças foram processadas para cortes histológicos sem descalcificação. As lâminas obtidas foram coradas pelo azul de toluidina e pelo picro-sirius que foram analisadas pelos microscópios óptico e de luz polarizada, respectivamente. Nas lâminas coradas pelo azul de toluidina, foi possível observar o tecido ósseo neoformado em contato com a superfície dos implantes com ósteons bem definidos. Nestas lâminas foram medidos os perímetros dos implantes para determinar o contato ósseo. As lâminas coradas pelo picro-sirius mostraram deposição de colágeno tipo I. A média de contato ósseo foi de 77,5% e o teste de contratorque aplicado nos implantes apresentou média de 76,13 Ncm. Considerando as limitações deste trabalho, foi possível concluir que a carga imediata em segmentos parcialmente desdentados é uma técnica viável para reabilitação bucal. / The objective of this work was to study the osseointegrated implants undergone immediately loading in dog mandibles, considering the bone quality formed in the implant-bone interface as well as bone contact. Four dogs were used, which after exodontics, received three Osseotite implants 3.75 x 8.5 (Implant Innovations Incorporation) and after the full-arch impression with custom tray and laboratorial procedures for the fabrication of the prosthesis in nickel chrome, this one were installed in the same day as the installation of the implants and was undergone a immediately loading. After 240 days, the mesial and distal implants were reverse torqued, measuring like this, the resistance of the neoformed osseous tissue. Soon after, the animals were sacrificed (240 days) and the samples were processed for histological examination by means of undescalcified sections without decalcification. The histologic specimens attained were stained with toluidine blue and with Picrus Sirius. After microscopical examination of the sections stained by toluidine blue with the optical microscope, it was possible to observe the neoformed osseous tissue and with the presence of well defined osteons. The histologic specimens stained with Picrus Sirius were analysed by polarized light microscope and they showed type I collagen deposition. The mean of osseous contact was of 77.5% between the implant and the bone, and the biomechanical test by means of reverse-torque presented a mean of 76.13 Ncm. Considering the limitations of this work it was possible to conclude that the immediately loading in partially edentulous segments is a viable technique for oral rehabilitation.

Page generated in 0.1203 seconds