• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 41
  • 41
  • 24
  • 21
  • 16
  • 12
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Polímeros de impressão molecular para extração seletiva de drogas em matrizes biológicas e determinação por LC-MS /MS e MS/MS / Molecularly imprinted polymer for selective extraction of drugs in biological matrices by LC-MS/MS e MS/MS

Fernandes, Raquel Maria Trindade, 1979- 22 August 2018 (has links)
Orientador: Marcos Nogueira Eberlin / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-22T00:48:57Z (GMT). No. of bitstreams: 1 Fernandes_RaquelMariaTrindade_D.pdf: 2391491 bytes, checksum: e0ced742cb6fd1e2732195078347fd99 (MD5) Previous issue date: 2012 / Resumo: O presente trabalho descreve a utilização de polímeros de impressão molecular (MIP) no preparo de amostra para a extração seletiva de fármacos em matrizes biológicas com determinação por LC-MS/MS e MS/MS. Inicialmente foi sintetizado e caracterizado um MIP seletivo a omeprazol, sendo o mesmo empregado na extração com fase sólida molecularmente impressa (MISPE) de omeprazol em amostras de plasma humano, seguido de determinação por LC-MS/MS. A metodologia foi validada por meio do estudo dos parâmetros: precisão (repetibilidade e precisão intermediária), exatidão (recuperação), curva analítica, intervalo de linearidade, limite de detecção ¿ LD e limite de quantificação ¿ LQ, e seletividade. O limite de quantificação obtido foi de 5 ng mL. Posteriormente, foi sintetizado e caracterizado um MIP seletivo a cocaína, sendo este empregado na extração em fase sólida molecularmente impressa (MISPE) online de cocaína em amostras de urina de usuários de drogas, seguido da quantificação por MS/MS. O limite de quantificação obtido foi de 10 ng mL. A seletividade do método foi avaliada pelo estudo de adsorção de metabólitos (benzoilecgonina e cocaetileno) e interferente (lidocaína) pelo polímero sintetizado e posterior determinação por MS/MS. / Abstract: The present work describes the applications of molecularly imprinted polymers (MIP) in sample preparation for the selective extraction of drugs in biological matrices by LC-MS/MS and MS/MS. Initially a MIP selective for omeprazolewas synthesized and characterized. It was used in molecularly imprinted solid phase extraction (MISPE) of omeprazole from human plasma samples, followed by LC-MS/MS determination. The methodology was validated by studying the parameters: precision (repeatability and intermediate precision), accuracy (recovery), calibration curve, linear range, detection limit - LOD and quantification limit - LOQ, and selectivity. The quantification limit was 5 ng ml. Subsequentlya MIP selective for cocaine was synthesized and characterizedwhich was used in online molecularly imprinted solid phase extraction (MISPE) for cocaine in urine samples of drug users, followed by quantification by MS / MS. The quantification limit was 10 ng mL. The selectivity of the method was evaluated by studying the adsorption of metabolites (benzoylecgonine and cocaethylene) and an interferent (lidocaine) by the synthesized polymer with subsequent determination by MS / MS. / Doutorado / Quimica Analitica / Doutora em Ciências
32

Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymers

José Eduardo dos Santos Clarindo 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
33

Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenac

Pereira, Abigail Vasconcelos 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (ν = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 µmol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 &micromol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin&reg, Afopic&reg e Folifolim&reg, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, ν = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac&reg, Medley&reg e Voltaren&reg e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (ν = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 &micromol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 &micromol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin&reg, Afopic&reg and Folifolim&reg,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac&reg, Medley&reg and Voltaren&reg and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
34

Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenac

Abigail Vasconcelos Pereira 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (ν = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 µmol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 &micromol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin&reg, Afopic&reg e Folifolim&reg, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, ν = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac&reg, Medley&reg e Voltaren&reg e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (ν = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 &micromol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 &micromol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin&reg, Afopic&reg and Folifolim&reg,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac&reg, Medley&reg and Voltaren&reg and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
35

Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymers

Clarindo, José Eduardo dos Santos 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
36

Desenvolvimento e aplicação de plataformas fundamentadas na tecnologia dos polímeros impressos molecularmente para detecção de 4-nitrofeno / Development and application of platforms based on polymer molecularly imprinted technology for detection of 4-nitrofenol

Cordeiro, Walker de Lima 20 June 2017 (has links)
The present work describes the development of a highly sensitive and selective molecularly imprinted electrochemical sensor for 4-nitrophenol detection. A glassy carbon electrode was modified with vyniltrimethoxisylane (VTMS) and multiwall carbon nanotubes (MWCNT). The introduced nanocomposite increased surface area and active sites for electron transfer. When the sillane is used on the synthesis, it is named MIS (molecularly imprinted silane) and NIS (non-imprinted silane) when the analyte is not on the synthesis. For those silane films characterization, it was used the scanning electron microscopy (SEM), thermogravimetric analysis (TGA) and fourier transform infrared spectroscopy (FTIR). This sensor showed its best performance in 0.1 mol L-1 phosphate buffer solution, at pH 7.0. After optimizing the operational conditions, this sensor provided a linear response range for 4-NP from 0.1 up to 100 μmol L-1 and good parameters as LOD, LOQ and sensibility, 0.03 μmol L-1, 0.1 μmol L-1 and 1.4×10-2 A mol L-1 respectively. Furthermore, the MIS/PNP sensor exhibited good stability with adequate reproducibility and accuracy. / No presente trabalho é descrito o desenvolvimento de um sensor eletroquímico altamente sensível e seletivo baseado na tecnolgia dos Polímeros Impresso Molecularmente para detecção de 4-nitrofenol. Um eletrodo de carbono vítreo foi modificado com viniltrimetoxisilano (VTMS) e nanotubos de carbono de pardes múltiplas (MWCNT). O nanocompósito de carbono introduzido aumentou a área superficial e os locais ativos para transferência de elétrons. No método sol-gel quando um sillano é usado na síntese, é denominado MIS (Molecular Imprinted Silane) e NIS (non-imprinted Silane) quando o analito não está na síntese. Para a caracterização dos filmes de silanos utilizou - se a microscopia eletrônica de varredura (MEV), a análise termogravimétrica (TGA) e a espectroscopia de infravermelho por transformação de Fourier (FTIR). Este sensor apresentou o seu melhor desempenho em solução tampão fosfato 0,1 mol L-1, a pH 7,0. Depois de otimizado as condições operacionais, este sensor proporcionou uma faixa de resposta linear para o 4-nitrofenol de 0,1 a 100 μmol L-1 e bons parâmetros como limite de detecção, quantificação e sensibilidade de 0,03 μmol L-1, 0,1 μmol L-1 e 1,4×10-2 A mol L-1 respectivamente. Além disso, o sensor MIS/4-nitrofenol apresentou boa estabilidade com reprodutibilidade e precisão adequadas.
37

SENSOR AMPEROMÉTRICO A BASE DE UM POLÍMERO DE IMPRESSÃO MOLECULAR COM PROTOPORFIRINA IX DE FERRO PARA A DETERMINAÇÃO DE 4-AMINOFENOL / AMPEROMETRIC SENSOR BASE OF AN IMPRESSION OF POLYMER MOLECULAR PROTOPORPHYRIN IX WITH IRON FOR THE DETERMINATION OF 4-AMINOPHENOL

Martins Neto, José de Ribamar 15 January 2010 (has links)
Made available in DSpace on 2016-08-19T12:56:34Z (GMT). No. of bitstreams: 1 Jose de Ribamar Martins Neto.pdf: 683212 bytes, checksum: dd95cedfe01600e58259c96b38a5f571 (MD5) Previous issue date: 2010-01-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work presents an analytical study on determination of 4-aminophenol (4-APh) with a system based on molecurlaly imprinted polymer (MIP) and iron protoporphyrin IX as biomimetic sensor of the peroxidase enzyme. The MIP synthesis was performed by the precipitation method and the analytical determinations by amperometric measurements with a glassy carbon electrode modified with the biomimetic system. The best analytical conditions established for 4-APh determination were: applied potential of -0.1 V vs. Ag/Agl, 0.05 mol L-1 Tris buffer solution, pH 7 and hydrogen peroxide concentration of 100 μmol L-1. Under such optimized conditions, a good linear sensor response was observed in a concentration range from 10 to 90 μmol L-1 (r>0.998), with detection and quantification limits of 3 and 10 μmol L-1, respectively. Experiments performed with tap and river water samples spiked with 4-APh resulted in 93 to 112 % recovery values, suggesting the viability of using the MIP/iron protoporphyrin IX system as biomimetic sensor for determinations of 4-APh in real samples. / O presente trabalho apresenta um estudo analítico da determinação de 4-aminofenol com um sistema a base de um polímero de impressão molecular (MIP, do inglês Molecularly Imprinted Polymer) e protoporfirina IX de ferro como sensor biomimético da enzima peroxidase. A síntese do MIP foi realizada pelo método de precipitação e as determinações analíticas realizadas amperometricamente com um eletrodo de carbono vítreo modificado com o sistema biomimético. As melhores condições analíticas estabelecidas para a determinação de 4-aminofenol foram: potencial aplicado de - 0,1V vs Ag/AgCl, tampão Tris 0,05 mol L-1, pH 7,0 e concentração de peróxido de 100 μmol L-1. Sob tais condições, uma boa resposta linear do sensor foi observada numa faixa de concentração de 10 a 90 μmol L-1 (r>0,9978), com limites de detecção e de quantificação de 3 e de 10 μmol L-1, respectivamente Experimentos realizados com amostras de águas de torneira e de rio fortificadas com 4-aminofenol, resultaram em valores de recuperação entre 93 a 112 %, indicando a viabilidade da aplicação do sistema MIP/proptoporfirina IX de ferro como sensor amperométrico para a detecção de 4-aminofenol em amostras reais.
38

Síntese de polímeros de impressão molecular e sua aplicação na técnica de extração em fase sólida

Peçanha, Bruna Rachel de Britto 23 March 2017 (has links)
Submitted by Biblioteca da Faculdade de Farmácia (bff@ndc.uff.br) on 2017-03-23T19:00:13Z No. of bitstreams: 1 Peçanha, Bruna Rachel de Britto [Dissertação, 2012].pdf: 3907379 bytes, checksum: f2acabc3c1c39363b86f0d651d6b5936 (MD5) / Made available in DSpace on 2017-03-23T19:00:13Z (GMT). No. of bitstreams: 1 Peçanha, Bruna Rachel de Britto [Dissertação, 2012].pdf: 3907379 bytes, checksum: f2acabc3c1c39363b86f0d651d6b5936 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Polímeros de impressão molecular (MIPs) foram sintetizados e aplicados como adsorventes na técnica de extração em fase sólida (EFS). O método de polimerização por precipitação foi utilizado para a síntese dos polímeros, devido à simplicidade de preparo, altos rendimentos e obtenção de partículas mais uniformes, devido a não trituração do polímero. O MIP foi sintetizado com ácido metacrílico (MAA) como monômero funcional, trimetacrilato de trimetilolpropano (TRIM) e dimetacrilato de etilenoglicol (EDMA) como agentes de reticulação e o cloridrato de amilorida (AMI) foi escolhido como molécula-molde. Diferentes proporções de MAA, TRIM, EDMA, volume e tipo de solvente foram utilizadas para ajuste das condições ideais de síntese. Os MIP foram avaliados quanto à capacidade de adsorção comparando-se a polímeros sintetizados na ausência da molécula-molde (NIP, polímeros não impressos). O solvente de elevada polaridade empregado na síntese (THF:MeOH:H2O) permitiu o emprego da técnica para moléculas polares como AMI. O controle no volume de solvente permitiu a obtenção de partículas maiores, de modo que a EFS foi realizada em condições usuais, o que confere um potencial para aplicação dessa técnica de polimerização na preparação de adsorventes para EFS. O polímero que apresentou maior capacidade adsortiva no ensaio realizado em tampão citrato-acetato pH 6,5 foi o MIP/NIP 12 (AMI:MAA:TRIM 1:8:10), com uma taxa média de adsorção de 83 e 88% para NIP e MIP, respectivamente. A adsorção foi elevada devido a interação iônica entre MAA e AMI promovida pelo controle de pH, porém foi não específica. O polímero MIP/NIP 12 foi aplicado como adsorvente na EFS, onde a recuperação de AMI foi avaliada nos resíduos de carregamento e eluição com solventes. O carregamento com tampão citrato-acetato pH 6,5 foi o ideal, favorecendo a interação iônica do polímero com o analito. A eluição total de AMI do cartucho somente ocorre após lavagem com o solvente na presença de ácido, que protona os grupos carboxila do polímero, rompendo assim a interação iônica com o analito / Molecularly imprinted polymers (MIPs) were synthesized and applied as adsorbents in solid-phase extraction technique (SPE). The polymers have been synthesized by precipitation polymerization method because of its simplicity, high yields and good control of final size and shape of particles. MIP was synthesized using methacrylic acid (MAA) as functional monomer, trimethylolpropane trimethacrylate (TRIM) and ethyleneglycol dimethacrylate (EDMA) as cross-linker and amiloride hydrochloride (AMI) was chosen as template. Different ratios of MAA, TRIM and EDMA, volume and type of solvent were used to adjust the optimal synthesis conditions. The MIP were tested for adsorption capacity compared to the polymers synthesized in the absence of template molecule (NIP, non-imprinted polymers). The polar solvent mixture used (THF:MeOH:H2O) allowed the synthesis of MIP of polar molecules as AMI. The solvent volume control afforded the larger particles so the SPE was performed in the usual conditions, giving a potential application for this polymerization technique in the preparation of adsorbents for SPE. The polymers with higher adsorption capacity at the test performed in citrateacetate buffer pH 6,5 was MIP/NIP 12 (AMI:MAA:TRIM 1:8:10) with adsorption rate of 83 and 88% for NIP and MIP, respectively. The recognition of MIP was due to ionic interaction between MAA and AMI promoted by pH control, but was not specific. The polymer MIP/NIP 12 was used as a solid-phase extraction sorbent and the recoveries of AMI was evaluated using different loading and elution conditions. The loading with buffer citrate-acetate pH 6,5 was optimal, due to ionic interaction of the polymer with the analyte. Total elution of AMI bound to the polymers only occurs after washing with a acid-containing solvent, because of protonation of the carboxyl groups of the polymer and disrupting the ionic interaction with the analyte
39

Desenvolvimento e otimização de procedimentos de extração em fase sólida molecularmente impressa (MISPE) e aplicação na determinação de diuréticos tiazídicos em urina por HPLC / Development and optimization of procedures of molecularly imprinted solid phase extraction (MISPE) and application in the determination of thiazide diuretics in urine by HPLC

Barros, Leonardo Augusto de, 1981- 25 February 2014 (has links)
Orientadores: Susanne Rath, Rogério Custódio / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-27T17:08:24Z (GMT). No. of bitstreams: 1 Barros_LeonardoAugustode_D.pdf: 4314419 bytes, checksum: 93a1b964e0a2949ef6a2379990e2f089 (MD5) Previous issue date: 2014 / Resumo: Esse trabalho teve como objetivo principal otimizar e sintetizar polímeros de impressão molecular (MIP) para serem empregados em processos de extração em fase sólida (SPE), visando a determinação de diuréticos tiazídicos em urina. Cálculos teóricos de modelagem molecular, usando o programa computacional Gaussian 09 e os métodos DFT e PCM, no nível B3LYP e conjunto de base 6-31G(d), foram realizados para selecionar o monômero funcional (MF) e o solvente porogênico mais adequados para serem utilizados na síntese dos MIP. Para o desenvolvimento dos MIP compatíveis com água, foi utilizado hidroclorotiazida, clorotiazida ou hidroflumetiazida como molde, acrilamida como MF, etilenoglicol dimetacrilato como reagente de ligação cruzada (RLC) e tetraidrofurano como solvente porogênico. Foram avaliados alguns parâmetros que afetam a eficiência do polímero de impressão, tais como a quantidade de MF e a natureza do RLC. Foram construídas as isotermas de adsorção para cada um dos polímeros sintetizados e foi avaliada a seletividade dos MIP frente a análogos estruturais dos moldes. Os polímeros foram caracterizados por infravermelho com transformada de Fourier, 13C RMN, microscopia eletrônica de varredura, porosimetria de sorção de nitrogênio e análise termogravimétrica. Os MIP foram empregados como fase estacionária em SPE para a determinação de diuréticos tiazídicos em urina por cromatografia líquida de alta eficiência e os mesmos apresentaram seletividade cruzada em relação aos análogos estruturais / Abstract: This work aimed to optimize and synthesize molecularly imprinted polymers (MIP) to be employed in processes of solid phase extraction (SPE), for the determination of thiazide diuretics in urine. Theoretical calculations of molecular modeling, using the Gaussian 09 software and the density functional theory and PCM methods, at the B3LYP/6-31G(d) level, were performed to select a the most appropriate functional monomer (FM) and porogenic solvent for the synthesis of the molecularly imprinted polymers (MIP). For the development of a water-compatible MIP chlorothiazide, hydrochlorothiazide or hydrfoflumethiazide were used as template, acrylamide as FM, ethyleneglycol dimethacrylate as cross-linker and tetrahydrofuran as porogenic solvent. Parameters that affect thepolymer efficiency, such as the amount of the monomer and nature of the cross-linker were evaluated. The adsorption isotherms for each of the synthesized polymers were constructed and the selectivities of the MIPs in relation to structural analogues of the templates were evaluated. The polymers were characterized by Fourier transform infrared, 13C NMR, scanning electron microscopy, nitrogen sorption porosimetry and thermogravimetric analysis. The MIPs were employed as stationary phase in SPE for the determination of thiazide diuretics in urine by high performance liquid chromatography and they showed cross-selectivity in relation to their structural analogues / Doutorado / Quimica Analitica / Doutor em Ciências
40

Degradação de profenofós em solução aquosa e em ervilhas processadas por feixe de elétrons e a síntese de polímeros impressos para extração seletiva desse pesticida / Degradation of profenofos in aqueous solution and peas by electron beam processed and synthesis of imprinted polymers for selective extraction of this pesticide

Flavio Thihara Rodrigues 10 April 2015 (has links)
Profenofós é um organofosforado empregado como inseticida e acaricida amplamente utilizado no Brasil para o controle de pragas de cebolas, milho, soja, café, tomate, algodão, feijão, batata e outros. A irradiação é um processo empregado em todo o mundo e recomendada por diversos órgãos de saúde para a conservação de alimentos. A radiação ionizante utiliza raios gama, raios X ou aceleradores de elétrons e tem sido aplicada para eliminar ou reduzir a ação de agentes patogênicos e contribuir para aumentar o tempo de estocagem de vários alimentos. Os objetivos desse trabalho foram: (a) avaliar a degradação de soluções aquosas de profenofós submetidas à radiação ionizante, identificar e quantificar a formação de novos produtos por GC-MS; (b) analisar o efeito de feixe de elétrons em ervilhas inoculadas com soluções aquosas de profenofós; (c) sintetizar Polímeros Molecularmente Impressos (MIP) e Sílica Impressa Molecularmente (MIS), posteriormente, caracterizar os adsorventes em fase sólida e verificar sua seletividade para profenofós. O tratamento com aceleradores de elétrons com dose 31,6 kGy promoveu a formação de um novo produto de degradação e redução de 93,40 % de profenofós em soluções aquosas. Em ervilhas inoculadas com 1 μg de profenofós submetidas à radiação ionizante de 30,4 kGy promoveu uma redução na concentração de profenofós em 57,46 %. Além disso, foram realizadas sínteses de MIP e MIS para a extração em fase sólida de profenofós. Os MIS sintetizados por sol-gel mostraram-se eficazes para o reconhecimento molecular e extração seletiva de profenofós. / Profenofos is an organophosphate widely used in Brazil as insecticide and acaricide in the control of pests in onions, corn, soybeans, coffee, tomato, cotton, beans, potatoes among others. Irradiation is a process used worldwide and recommended by many health agencies for food preservation. Food irradiation preserving process uses accelerated electrons, gamma rays or X-rays. Ionizing radiation treatment is applied to eliminate or to reduce the action of pathogens and to increase the shelf life of some foods. The objective of this study were (a) to evaluate the degradation of aqueous solutions of Profenofos by ionizing radiation, identify and quantify the formation of new products by GC-MS; (b) to analyze the effects of electron beam in peas inoculated with aqueous solutions of Profenofos; (c) to synthesize Molecularly Imprinted Polymer (MIP) and Molecularly Imprinted Silica (MIS), subsequently characterize the adsorbents in solid phase and check its selectivity for profenofos. The treatment with electron accelerators with 31.6 kGy dose promoted the formation of a new by-product and 93.40 % reduction of profenofos in aqueous solutions. In peas inoculated with 1 μg of profenofos by ionizing radiation of 30.4 kGy promoted a reduction of 57.46 % in the concentration of profenofos. Furthermore, the MIP and MIS were performed for solid phase extraction of profenofos. The MIS synthesized by sol-gel proved to be effective for the recognition molecular and selective extraction of profenofos.

Page generated in 0.0583 seconds