Spelling suggestions: "subject:"compressão molecular.""
1 |
Detecção e quantificação de corantes de importância ambiental empregando sensores químicos baseados em fibras ópticas e polímeros molecularmente impressosFoguel, Marcos Vinicius [UNESP] 27 November 2015 (has links) (PDF)
Made available in DSpace on 2016-05-17T16:51:52Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-11-27. Added 1 bitstream(s) on 2016-05-17T16:55:49Z : No. of bitstreams: 1
000863712_20170110.pdf: 884354 bytes, checksum: 9a614c3a6fbd6b8ab01037743ea320f5 (MD5) Bitstreams deleted on 2017-01-11T12:50:20Z: 000863712_20170110.pdf,. Added 1 bitstream(s) on 2017-01-11T12:50:59Z : No. of bitstreams: 1
000863712.pdf: 5082887 bytes, checksum: 2828da2340b50810c6223ed7cd8103d5 (MD5) / Efluentes industriais contendo corantes são diariamente liberados no meio ambiente. O lançamento de efluentes têxteis provoca uma degradação ambiental considerável, modificando a coloração natural e prejudicando o sistema biológico aquático. Dentre esses corantes, a classe de corantes trifenilmetano é largamente empregada na indústria têxtil e apresenta problemas à saúde pública e ao meio ambiente quando despejados nos efluentes, devido à alta toxicidade e difícil degradação. Uma alternativa para a detecção e quantificação destes compostos é o desenvolvimento de sensores biomiméticos com transdução óptica, empregando como sistema de reconhecimento polímeros molecularmente impressos (MIP). A vantagem desta metodologia é a boa seletividade, sensibilidade, estabilidade dos MIP e baixo custo dos materiais empregados. O presente trabalho explora diferentes sínteses de polímeros impressos para os corantes têxteis: Vermelho Básico 9 (BR9), Verde Ácido 16 (AG16) e Verde de Metila (MG). Para isso foram avaliadas sínteses com diferentes monômeros funcionais e proporções molares entre os reagentes empregados para a polimerização. Todos os MIP apresentaram melhor desempenho na proporção 1:3:200 de molécula molde, monômero funcional e monômero estrutural, respectivamente. O corante BR9 mostrou boa interação com o monômero funcional ácido 2-acrilamino-2-metilpropano sulfônico por meio de ligação de hidrogênio, enquanto que os corantes AG16 e MG apresentaram afinidade com o monômero 1-vinilimidazol, por meio de interação íon-dipolo e π-cátion, respectivamente. Os MIP para os corantes BR9 e AG16 apresentaram boa porcentagem de religação (70 e 86%, respectivamente), fatores de impressão bastante satisfatórios (1,82 e 6,91, respectivamente) alta seletividade frente a outros corantes têxteis e grande eficiência na extração dos respectivos corantes em amostra... / Industrial effluents containing dyes are daily released to the environment. The launch of textile effluents causes a considerable environmental degradation, changing the natural color and harming the aquatic biological system. Among these dyes, the class of triphenylmethane dyes is widely used in the textile industry and it presents problems to public health and the environment when discharged in the effluent due to the high toxicity and difficult degradation. An alternative for the detection and quantification of these compounds is the development of biomimetic sensors with optical transduction, employing Molecularly Imprinted Polymers (MIP) as recognition system. The advantage of this methodology is the good selectivity, sensitivity and stability of the MIP and low cost of materials. This work explores different synthesis of MIP for the textile dyes: Basic Red 9 (BR9), Acid Green 16 (AG16) and Methyl Green (MG). For this, the syntheses were evaluated with different functional monomers and molar ratios among the reagents employed for the polymerization. All MIP showed better performance in the ratio 1:3:200 of template, functional monomer and structural monomer, respectively. The dye BR9 showed good interaction with the functional monomer 2-acrylamido-2-methyl-1-propanesulfonic acid by hydrogen bonding, while the dyes MG and AG16 have affinity with the monomer 1-vinylimidazole, by electrostatic and π-cation interaction, respectively. MIP for dyes BR9 and AG16 have good percentage of rebinding (70 and 86%, respectively), satisfactory imprinting factor (1.82 e 6.91, respectively), high selectivity in comparison with other textile dyes and high efficiency in extraction of the respective dyes in sample of textile industrial effluent, presenting recoveries around of 100%. However, the MIP for the dye MG has not presented satisfactory results, with rebinding values below 20%. Probably the MIP performance...
|
2 |
Desenvolvimento de sensor eletroquímico baseado em polímero molecularmente impresso para determinação de hexahidrofarnesol em bioquerosene de aviação /Buffon, Edervaldo. January 2018 (has links)
Orientador: Nelson Ramos Stradiotto / Banca: Denis Ricardo Martins de Godoi / Banca: Marcelo Firmino de Oliveira / Resumo: A atual expansão do setor de aviação tem aumentado à dependência das companhias aéreas ao querosene de aviação e a outros derivados fósseis. A dependência desse setor para com esses combustíveis se reflete em grandes índices de poluição atmosférica devido à emissão do CO2 proveniente da queima dessas substâncias. Tendo em vista a necessidade de reduzir esse poluente, têm-se desenvolvido novas tecnologias para a produção de querosenes alternativos de aviação (bioquerosenes de aviação). Uma das formas de obtenção do bioquerosene de aviação é a partir da fermentação de açúcares. O biocombustível obtido através dessa rota tecnológica é composto basicamente pelo farnesano e possui como principal contaminante o hexahidrofarnesol. A preocupação com a presença do hexahidrofarnesol no bioquerosene de aviação se deve principalmente a sua solubilidade em água e a degradação dos componentes do sistema de combustível. Diante disso, se fazem necessárias metodologias analíticas simples, sensíveis, seletivas e de baixo custo para determinar esse contaminante no bioquerosene de aviação. Uma vez que essas características são encontradas nos sensores eletroquímicos, o objetivo deste trabalho consiste no desenvolvimento de um sensor eletroquímico baseado em polímero molecularmente impresso para a determinação de hexahidrofarnesol em bioquerosene de aviação. O sensor proposto foi preparado pela eletropolimerização da o-fenilenodiamina sobre um eletrodo de carbono vítreo na presença da molécula de hexahidrofarnesol pela técnica de voltametria cíclica. O eletrodo modificado foi caracterizado por várias técnicas, tais como voltametria cíclica, espectroscopia de impedância eletroquímica, microscopia eletrônica de varredura, espectroscopia RAMAN e microscopia de força atômica. Os parâmetros que influenciam o desempenho do sensor impresso, como a razão... / Abstract: Current expansion of the aviation sector has increased the dependence of airlines to aviation kerosene and other fossil derivatives. Dependence of this sector to such fuels is reflected in high rates of air pollution due to the emission of CO2 originated from burning of these substances. In view of the need for lower emissions these pollutants, new technologies have been developed for the production of alternative aviation kerosene (aviation biokerosene). One of the ways of get the aviation biokerosene is from the fermentation of sugars. The biofuel obtained through this technological route is basically composed of farnesane, and it has as main contaminant the hexahydrofarnesol. The concern with the presence of hexahydrofarnesol in aviation biokerosene is mainly due to its solubility in water and the degradation of fuel system components. Thus, the developments of simple, sensitive, selective and low cost analytical methodologies to determine such contaminant in the aviation biokerosene are necessary. Once these characteristics are found in the electrochemical sensors, the objective of this work consists in the development of an electrochemical sensor based on molecularly imprinted polymer for the determination of hexahydrofarnesol in aviation biokerosene. The proposed sensor was prepared by electropolymerization of the o-phenylenediamine on a glassy carbon electrode in the presence of the hexahydrofarnesol molecule by the cyclic voltammetry technique. The modified electrode was characterized by several techniques, such as cyclic voltammetry, electrochemical impedance spectroscopy, scanning electron microscopy, RAMAN spectroscopy, and atomic force microscopy. Parameters that influence the performance of the imprinted sensor, such as the molar ratio between the functional monomer and the template molecule, the number of cycles used in the electropolymerization, the pH of the solution used during the... / Mestre
|
3 |
Sensores eletroquímicos para determinação de polióis na vinhaça de cana-de-açúcar baseados em eletrodos modificados com polímeros molecularmente impressos em grafeno contendo nanopartículas metálicas /Beluomini, Maísa Azevedo. January 2018 (has links)
Orientador: Nelson Ramos Stradiotto / Banca: Sonia Maria Alves Jorge / Banca: Leonardo Lataro Paim / Banca: André Luiz dos Santos / Banca: Rodrigo Alejandro Abarza Munoz / Resumo: A vinhaça é um expressivo coproduto da destilação do etanol que apesar de ser considerada poluidora, vem sendo utilizada como fertilizante nas plantações de cana-de-açúcar, colocando em risco a contaminação de aquíferos subterrâneos e salinização do solo. Cerca de 10 a 18 litros de vinhaça são produzidos por litro de etanol destilado e sua constituição é de principalmente sais de potássio, cálcio, magnésio e compostos orgânicos. Dentre estes, os polióis tornam-se importantes compostos por estarem presentes em concentrações altamente significativas e também por apresentar expressiva importância na indústria farmacêutica e alimentícia. Com isso, o conceito de biorrefinarias surge como a possibilidade das usinas terem um pleno aproveitamento deste resíduo, garantindo fins mais lucrativos e ecológicos. Assim, é de grande importância o desenvolvimento de novos métodos para determinação desses compostos, com destaque aos eletroanalíticos, que vem nos últimos anos se destacando por apresentar métodos de análises confiáveis mesmo em baixas concentrações do analito, pequenos volumes de amostra e em matrizes complexas que requerem alta especificidade. Sendo assim, nesse trabalho foi desenvolvido sensores eletroquímicos baseados na técnica de impressão molecular, capaz de produzir polímeros que incorporam as moléculas de interesse em sua estrutura e que são capazes de formar locais específicos de reconhecimento molecular, tornando-se atrativos devido a sua elevada seletividade e estabil... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Vinasse is an expressive co - product of ethanol distillation, which despite being conside red polluting, has been used as fertilizer in sugarcane plantations, which may put at risk the contamination of groundwater and soil salinization. About 10 to 18 liters of vinasse are produced per liter of distilled ethanol and its composition is mainly of salts of potassium, calcium, magnesium and organic compounds. Among these, polyols become important compounds because they are present in highly concentrations and also due to its importance in the pharmaceutical and food industry . With this, the concept of biorefineries becomes a possibility for the sugar cane plants to take full advantage of this residue, guaranteeing more profitable and ecological ends. Thus, the development of new methods for the determination of these compounds is very important, wit h emphasis on electroanalytical methods, which recently has been presenting reliable methods of analysis even at low analyte concentrations, small sample volumes and in complex matrices that require high specificity . So, in this work, we developed electroc hemical sensors based on the molecular imprinted technique, capable of producing polymers that incorporate the molecules of interest in their structure and that are able to form specific sites of molecular recognition . Therefore, this work reports the deve lopment of an electrochemical method for the determination of polyols based on molecularly imprinted polymers (MIP) using go... (Complete abstract click electronic access below) / Doutor
|
4 |
Catalisadores para esterificação e transesterificação e modificações de eletrodos de pasta de carbono para detecção de fosfatos baseados na técnica de molecular imprintingQuint, Marcelo Luiz January 2014 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, Florianópolis, 2014. / Made available in DSpace on 2015-02-05T20:28:30Z (GMT). No. of bitstreams: 1
331120.pdf: 2953652 bytes, checksum: 507eb391a7d246fb1efeb29cdb208ab1 (MD5)
Previous issue date: 2014 / Esta tese objetivou o desenvolvimento de catalisadores para as reações de esterificação e transesterificação bem como eletrodos sensíveis a fosfatos, ambos por intermédio da técnica de impressão molecular. Para o desenvolvimento de eletrodos planejou-se e preparou-se uma série de sensores para o grupo fosfato utilizando-se a técnica de impressão molecular baseada em interações não covalentes entre o modelo fosfato de dipentila com o monômero funcional ácido metacrílico. Utilizou-se a técnica eletroquímica de voltametria de onda quadrada com eletrodos de pasta de carbono modificados para a detecção específica de fosfatos. Conseguiu-se linearidade em curvas de calibração na faixa entre 20 e 300 nmol L-1. Alcançou-se o limite de detecção de 8,82 nmol L-1. Não se detectou a presença dos íons carbonato, sulfato e nitrato quando utilizados em concentrações 100 vezes maiores que as de trabalho. Demonstrou-se seletividade a fosfatos de dialquila com cadeias menores ou iguais às do modelo utilizado. Esses polímeros não apresentaram atividade catalítica para as reações testadas. Fez-se o planejamento de catalisadores baseados na interação entre o modelo fosfato de dibutila e combinações dos monômeros funcionais ácidos acrílico e metacrílico, 1-vinilimidazol e metacrilato de 2-hidroxietila na tentativa de mimetizar a tríade catalítica de lipases. Os polímeros resultantes não apresentaram atividade catalítica frente às reações testadas. Apesar de não resultar em materiais catalíticos com o modelo fosfato de dipentila, evidenciou-se sucesso na impressão molecular, dada a alta seletividade apresentada nas técnicas eletroquímicas estudadas. Já a impressão com fosfato de dibutila mimetizando a tríade catalítica da lipase não pôde ser evidenciada pelos estudos de catálise. Esses materiais atualmente são objetos de estudos eletroquímicos para a comprovação do êxito na impressão molecular, bem como para o desenvolvimento de sensores de pasta de carbono modificados para a detecção e quantificação de fosfatos de dialquila com cadeias de até três átomos de carbono. Os materiais resultantes desta tese podem futuramente ser utilizados em outras aplicações de polímeros impressos molecularmente, como fases fixas de técnicas cromatográficas.<br> / Abstract : This thesis have aimed the development of esterification and transesterification catalysts as well as the development of phosphate sensors by the use of molecular imprinting. A series of size-selective polymeric sensors for the phosphate group were designed and synthesized using the molecularly imprinted polymer (MIP) technique based upon the non-covalent interactions of the template dipentyl phosphate with the functional monomer methacrylic acid. Electrochemical detection, performed by square wave voltammetry (SWV) with a modified carbon paste electrode (CPE), showed very low-range specific detection of phosphate molecules. Calibration curves were plotted within a linear range of 20 to 300 nmol L-1 for all modified CPEs, with the lowest detection limit (DL) determined as 8.82 nmol L-1. Inorganic interfering agents, such as carbonate, nitrate and sulfate ions, were analyzed and no signal disturbance was observed for relative concentrations 100 times higher. Furthermore, the modified electrodes also showed good selectivity for phosphate molecules containing alkyl chains with up to five carbon atoms. These selectivity studies showed that imprinted sites were successfully synthesized and only structures that are equal to or smaller than those of the template molecule are selected by maximizing intermolecular interactions within the MIP binding site. Moreover, the sensors presented good stability, maintaining the same selectivity for several months. Although the great success in electrochemical activities, these polymers do not showed any catalytic activity for the esterification reactions. It was planned other catalysts based on molecularly imprinted polymer technique based upon the non-covalent interactions of the template dibutyl phosphate with combination of the functional monomers methacrylic acid, acrylic acid, 1-vinylimidazole and 2-hydroxyethyl methacrylate in attempt to mimic lipases catalytic triad. These polymers also do not present catalytic activity. These materials are subjects of electrochemical studies for detection and quantification of dialkyl phosphates with alkyl chains up to 3 carbons. The materials produced in this thesis would be used in other MIP applications, as stationary phases of chromatographic technics.
|
5 |
Detecção e quantificação de corantes de importância ambiental empregando sensores químicos baseados em fibras ópticas e polímeros molecularmente impressos /Foguel, Marcos Vinicius. January 2015 (has links)
Orientador: Maria del Pilar Taboada Sotomayor / Banca: Paulo Clairmont Feitosa de Lima Gomes / Banca: Gustavo Troiano Feliciano / Banca: Débora Gonçalves / Banca: Ivo Milton Raimundo Junior / Resumo: Efluentes industriais contendo corantes são diariamente liberados no meio ambiente. O lançamento de efluentes têxteis provoca uma degradação ambiental considerável, modificando a coloração natural e prejudicando o sistema biológico aquático. Dentre esses corantes, a classe de corantes trifenilmetano é largamente empregada na indústria têxtil e apresenta problemas à saúde pública e ao meio ambiente quando despejados nos efluentes, devido à alta toxicidade e difícil degradação. Uma alternativa para a detecção e quantificação destes compostos é o desenvolvimento de sensores biomiméticos com transdução óptica, empregando como sistema de reconhecimento polímeros molecularmente impressos (MIP). A vantagem desta metodologia é a boa seletividade, sensibilidade, estabilidade dos MIP e baixo custo dos materiais empregados. O presente trabalho explora diferentes sínteses de polímeros impressos para os corantes têxteis: Vermelho Básico 9 (BR9), Verde Ácido 16 (AG16) e Verde de Metila (MG). Para isso foram avaliadas sínteses com diferentes monômeros funcionais e proporções molares entre os reagentes empregados para a polimerização. Todos os MIP apresentaram melhor desempenho na proporção 1:3:200 de molécula molde, monômero funcional e monômero estrutural, respectivamente. O corante BR9 mostrou boa interação com o monômero funcional ácido 2-acrilamino-2-metilpropano sulfônico por meio de ligação de hidrogênio, enquanto que os corantes AG16 e MG apresentaram afinidade com o monômero 1-vinilimidazol, por meio de interação íon-dipolo e π-cátion, respectivamente. Os MIP para os corantes BR9 e AG16 apresentaram boa porcentagem de religação (70 e 86%, respectivamente), fatores de impressão bastante satisfatórios (1,82 e 6,91, respectivamente) alta seletividade frente a outros corantes têxteis e grande eficiência na extração dos respectivos corantes em amostra... / Abstract: Industrial effluents containing dyes are daily released to the environment. The launch of textile effluents causes a considerable environmental degradation, changing the natural color and harming the aquatic biological system. Among these dyes, the class of triphenylmethane dyes is widely used in the textile industry and it presents problems to public health and the environment when discharged in the effluent due to the high toxicity and difficult degradation. An alternative for the detection and quantification of these compounds is the development of biomimetic sensors with optical transduction, employing Molecularly Imprinted Polymers (MIP) as recognition system. The advantage of this methodology is the good selectivity, sensitivity and stability of the MIP and low cost of materials. This work explores different synthesis of MIP for the textile dyes: Basic Red 9 (BR9), Acid Green 16 (AG16) and Methyl Green (MG). For this, the syntheses were evaluated with different functional monomers and molar ratios among the reagents employed for the polymerization. All MIP showed better performance in the ratio 1:3:200 of template, functional monomer and structural monomer, respectively. The dye BR9 showed good interaction with the functional monomer 2-acrylamido-2-methyl-1-propanesulfonic acid by hydrogen bonding, while the dyes MG and AG16 have affinity with the monomer 1-vinylimidazole, by electrostatic and π-cation interaction, respectively. MIP for dyes BR9 and AG16 have good percentage of rebinding (70 and 86%, respectively), satisfactory imprinting factor (1.82 e 6.91, respectively), high selectivity in comparison with other textile dyes and high efficiency in extraction of the respective dyes in sample of textile industrial effluent, presenting recoveries around of 100%. However, the MIP for the dye MG has not presented satisfactory results, with rebinding values below 20%. Probably the MIP performance... / Doutor
|
6 |
Desenvolvimento de sensor baseado em polímeros molecularmente impressos para determinação de álcoois superiores em óleo fúsel /Mariano, Thiago de Morais. January 2016 (has links)
Orientador: Nelson Ramos Stradiotto / Banca: Hideko Yamanaka / Banca: Luiz Henrique Mazo / Resumo: O óleo fúsel é o co - produto da destilação do etanol e é formado pela mistura de álcoois superiores (álcoois com mais de 3 carbonos), ésteres, aldeídos, entre outros . O volume de óleo fúsel produzido em média é 2,5 L de óleo fúsel por 1000 L de etanol, sendo utilizado como combustível nas caldeiras das usinas, bem como precursores de ésteres utilizados em indústrias de cosméticos e em fabricação de plásticos. O presente trabalho teve como objetivo desenvolver um sensor eletroq uimico (GCE/ RGO /AuNP/MIP) baseado em polímeros molecularmente impressos (MIP), utilizando o pirrol (Py) como monômero, contendo nanopartículas de ouro (AuNP) e óxido de grafeno reduzido ( R GO ) para a de terminação do álcool isoamílico, um dos componentes do óleo fusel. Foram realizados estudos eletroquímicos, como estudo de velocidade de varredura, para determinar reversibilidade do sistema e diagnosticar o controle do processo eletródico. Após os estudos eletroquímicos, foram realizadas caract e rizaç ão morfol ógica por Microscopia Eletrônica de Varredura com Canhão de Emissão de Eletrons c om efeito de campo (MEV - FEG) e caracterização eletroquimica por Espectroscopia de Impedancia Eletroquímica (EIS). A pós a caracterização, foi avaliada a performance analítica do sensor GCE/ RGO /AuNP/MIP, utilizando um intervalo de concentração de 1,0 × 10 - 7 até 1,0 × 10 - 4 mol L - 1, encontra ndo um limite de detecção de 8,2 × 10 - 8 mol L - 1 . F oi determinada a concentração de álcool isoamí lico em amostra de óleo fúsel pelo método de adição de padrão e o valor encontrado foi de 1,6 ×10 - 4 mol L - 1 . O método foi validado através de ensaio de recuperação, mostrando que o sensor desenvolvido é promissor para a utilização em determinação de álcool isoamílico em óleo fúsel. / Abstract: The fusel oil is co - product of the distillation of ethanol and is formed by the mixture of higher alcohols (alcohols having more than 3 carbons) esters, aldehydes, etc. The volume of fusel oil produced on average is 2.5 L fusel oil by 1000 L of ethanol, used as fuel in the boilers of the plants, as well as esters of precursors used in the cosmetics and plastics manufacturing. This study aimed to develop an electrochemical sensor (GCE/ RGO /A u NP/MIP) based on molecularly imprinted polymers (MIP), using pyrrole (Py) as the monomer, containing gold nanoparticles (AUNP) and reduced graphene oxide (RGO) for determining the isoamyl alcohol, one of fusel oil compo nents. They were conducted electrochemical studies, such as study of scanning speed, to determine system reversibility and diagnose the control of the electrode process. After the electrochemical studies were conducted morphological caractrização by Scanni ng Electron Microscopy with Electrons Emission Cannon with field effect (SEM - FEG) and electrochemical characterization by spectroscopy Electrochemical Impedance (EIS). After the characterization, the analytical performance of the GCE/ RGO /AuNP/MIP sensor wa s evaluated using a concentration range of 1.0×10 - 7 to 1.0×10 - 4 mol L - 1, encountering a detection limit 8.2×10 - 8 mol L - 1 . Was determined the concentration of isoamyl alcohol in a sample of fusel oil by standard addition method and the value found was 1.6×1 0 - 4 mol L - 1 . The method was validated by recovery test, showing that the sensor is designed promising for use in determining isoamyl alcohol fusel oil. / Mestre
|
7 |
Emprego de um polímero de impressão molecular restrito à ligação com macromoléculas por meio de revestimento com albumina para extração on-line de ivermectina em carne bovina seguido de análise por HPLC-UVLIMA, Marcela Marília de 21 January 2014 (has links)
A ivermectina (IVM) é um antiparasitário mundialmente utilizado na criação de animais. No entanto, quando o tempo de carência não é respeitado, resíduos de IVM são encontrados nos produtos de origem animal podendo causar danos à saúde humana. Assim, foi estabelecido em diversos países um limite máximo de resíduo (LMR) para este fármaco. Portanto, amostras de carne contendo IVM acima dos valores estabelecidos são consideradas adulteradas e têm sido a causa do embargo das exportações de carne bovina do Brasil, que é atualmente o maior país exportador deste produto no mundo. Os níveis de resíduos de IVM nos tecidos geralmente são muito baixos, pois este fármaco é capaz de produzir efeito terapêutico em pequenas doses. Assim, é necessário o emprego de técnicas sensíveis e seletivas de preparo de amostras e análise para verificar a presença de IVM em carne. Neste sentido, o principal objetivo deste trabalho foi sintetizar um polímero de impressão molecular restrito à ligação com macromoléculas por meio de revestimento com albumina (RAMIP-BSA), e empregar o mesmo na extração on-line de IVM em extratos proteicos de carne bovina, seguido de análise por cromatografia líquida de alta eficiência (CLAE) com detector por absorção no ultravioleta (UV). A IVM foi inicialmente extraída de amostras de carne moída empregando-se uma mistura de metanol:água (70:30, v/v), e o extrato resultante foi diretamente analisado pelo sistema on-line de extração e separação. O método apresentou linearidade na faixa de 50 a 500 μg kg-1 com precisão de 3,8 a 17,0% e exatidão de -18,5 a 22,0%. Os limites de detecção e quantificação foram de 30 e 50 μg kg-1, respectivamente, sendo menores que o LMR para IVM em carne bovina que é de 100 μg kg-1. O método foi considerado robusto e seletivo, tendo sido empregado com sucesso na monitorização de IVM em amostras de carne bovina. / Ivermectn (IVM) is an antiparasitic drug worldwide used in livestock. However, when the grace period is not respected, IVM residues can be found in animal source products and can cause damages to the human health. Thus, it was established in many countries a maximum limit of residue (MRL) to this drug. Therefore, meat samples that contain IVM above the established values are considered adulterated and have been the cause of exportations embargo of meat from Brazil. IVM is able to produce a therapeutic effect even in lower doses. Hence, the residues levels in the tissues are usually very low, which makes necessary the use of selective and sensitive techniques of sample preparation and analysis. Thus, the main objective of this work was to synthesize a restricted access molecularly imprinted polymer coated with bovine serum albumin (RAMIP-BSA) and to employ it in the on-line extraction of IVM in minced meat samples, followed by a high performance liquid chromatography (HPLC) with an UV detector. The method has shown linearity from 50 to 500 μg kg-1, with precision and accuracy ranging from 3.8 to 17.0 and from -18.5 to 22.0, respectively. The detection and quantification limits were 30 e 50 μg kg-1 respectively. The method can be used in the monitoring of IVM in beef samples.
|
8 |
Desenvolvimento de um disco de extração em fase sólida molecularmente impresso para a pré-concentração seletiva de tetraciclinas em amostras de água seguida de análise por HPLC-UVABRÃO, Lailah Cristina de Carvalho 30 August 2013 (has links)
Os poluentes orgânicos emergentes vêm se tornando fonte crescente de preocupação ambiental. Entre as classes mais comumente encontradas em amostras de águas estão os antibióticos, com destaque para as tetraciclinas. A ocorrência destes analitos em níveis muito baixos torna necessária a utilização de técnicas de extração seletivas e sensíveis capazes de pré-concentrar tais analitos na presença de concomitantes mais abundantes. Nesse sentido, acredita-se que os polímeros de impressão molecular (MIP) se enquadram perfeitamente para tal aplicação principalmente devido a características como seletividade e sensibilidade. Adicionalmente, o emprego de 2-hidroxietil metacrilato (HEMA) e o glicerol dimetacrilato (GDMA) durante a síntese aumenta a quantidade de hidroxilas superficiais, que por sua vez tornam o material mais compatível com sistemas aquosos, uma vez que há predomínio de interações de hidrogênio entre a água e as hidroxilas superficiais, minimizando a perturbação desse solvente na ligação analito-MIP. Sendo assim, o objetivo do presente trabalho foi desenvolver um disco de MIP com revestimento superficial hidrofílico para extração de tetraciclinas de amostras de águas seguida de análise por HPLC-UV. O MIP foi sintetizado utilizando-se oxitetraciclina como molécula-modelo, ácido metacrílico como monômero funcional, etileno glicol dimetacrilato como agente de ligação cruzada, 2,2’-azo-bis-iso-butironitrila como iniciador radicalar e HEMA e GDMA como comonômeros hidrofílicos. O material (1 g) foi então comprimido na forma de um disco de 40 mm de d.i. por 2 mm de espessura e empregado em procedimentos de extração em fase sólida em disco. A metodologia mostrou-se promissora para a extração seletiva de tetraciclinas com linearidade, precisão e exatidão adequadas e, com limites de quantificação da ordem de 5 µg L-1. / Emerging organic pollutants have caused great environmental concern. Among the most common pharmaceuticals, antibiotics are in focus, especially tetracyclines. The occurrence of these analytes at low levels makes necessary the use of selective and sensitive extraction techniques to enrich those compounds even in the presence of other concomitant interferents. In this way, it is thought that molecularly imprinted polymers (MIPs) fit perfectly to this application mainly due to their characteristics of selectivity and sensitivity. In addition, the use of 2-hydroxyethyl methacrylate (HEMA) and glycerol dimethacrylate (GDMA) during the synthesis increases the number of surface hydroxyl groups, which in turns makes the polymer more compatible with aqueous systems, since they enhance the hydrogen bonds between the water and surface hydroxyl groups, minimizing the interference of this solvent in the complex analyte-polymer. Thus, the objective of this project was to develop a MIP disk for the extraction of tetracyclines from water samples followed by the HPLC-UV analysis. The MIP was synthesized using oxytetracycline as template, methacrylic acid as functional monomer, ethylene glycol dimethacrylate as the cross-linker agent, 2,2’-azo-bis-iso-butyronitrile as radical initiator and HEMA and GDMA as hydrophilic monomers. The polymer was then compressed in a disk form of 40 mm of internal diameter and 2 mm of thickness and this system was used in solid-phase extraction procedures. The developed method showed great results for selective extraction of tetracyclines with good linearity, precision and accuracy showing limits of quantification of 5 µg L-1. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
|
9 |
Microextração em fase sólida molecularmente impressa de triazóis em amostras de água e suco de uva seguido de análise por GC-MSFREITAS, Lissara Aparecida de Souza 24 January 2014 (has links)
O uso de praguicidas na agricultura é uma das maiores fontes de contaminação ambiental, uma vez que tais compostos são lixiviados e disseminados em águas superficiais, subterrâneas e no solo, tornando-se um problema para a fauna, flora e para a saúde humana. Além disso, resíduos de praguicidas muitas vezes são encontrados em alimentos devido à utilização inadequada em super dosagens. Nesse sentido, faz-se necessário o desenvolvimento de técnicas analíticas de preparo de amostras apropriadas para a extração e pré-concentração desses praguicidas nos recursos hídricos e em alimentos. Dentre essas técnicas podemos destacar a microextração em fase sólida molecularmente impressa (MISPME) devido a características vantajosas como seletividade, menor consumo de solventes orgânicos, tempo reduzido de extração, baixo custo para a construção da fibra, dentre outras. Sendo assim, o presente trabalho tem como objetivo sintetizar e caracterizar uma fibra para MISPME com superfície renovável para a extração de triazóis em amostras de água e de suco de uva seguido de análise por CG-MS. De acordo com Ministério da Agricultura, Pecuária e Abastecimento (MAPA) os limites máximos de resíduo (LMR) para triadimenol, tebuconazol e metconazol em uva são respectivamente de 0,1, 2,0, e 1,0 mg kg-1. E o limite máximo de tolerância (LMT) de triazóis em água, estabelecido por órgãos internacionais, é de 0,1 μg L-1 para cada praguicida e de 0,5 μg L-1 para um total deles. O epoxiconazol foi selecionado como padrão interno por ser proibido na cultura de uva. Para a análise em suco de uva, a faixa analítica do método compreende de 100 μg L-1 a 2000 μg L-1 para triadimenol, tebuconazol e metconazol, com LQ de 100 μg L-1 para todos os analitos. Para análise em água, a faixa analítica do método compreende de 100 μg L-1 a 3000 μg L-1, com LQ de 100 μg L-1. O método proposto para análise de triazóis em suco de uva atendeu todas as especificações requeridas em termos de figuras de mérito. Contudo, a detectabilidade do método foi insuficiente para análises de triazóis em águas devido aos baixos limites preconizados pela legislação (0,5 μg L-1). / The use of pesticides in agriculture is a major source of environmental contamination since such compounds are leached and disseminated in surface water, groundwater and soil water, making it a problem for fauna, flora and human health. Moreover, pesticide residues are frequently found in food due to their uncontrolled use. Thus, it is necessary to develop analytical techniques of sample preparing for both pesticide extraction and concentration in water resources as well as food. Among these techniques, we can highlight the molecularly imprinted solid phase micro extraction (MISPME), due to its particular advantages as high selectivity, low organic solvent consumption, low extraction time, low cost of fiber fabrication, among others. Therefore, the present study's aim is to synthesize and characterize a new fiber for MISPME to extract triazoles from environmental and food samples followed by GC/MS analysis. According to MAPA (Ministry of Agriculture and Livestock) MRLs for grape triadimenol, tebuconazole, epoxiconazol and metconazole are respectively 0.1 mg kg-1, 2 mg kg-1 prohibited to grape culture and 1 mg kg-1. Knowing that epoxiconazole is prohibited to grape culture, it was selected as internal standard. The tolerance limit in water is established by international organizations, such as tolerance embrace a concentration of 0.1 mg L-1 for each pesticide and 0,5 mg L-1 for a total of them. For grape juice analysis, the analytical range of the method comprises from 100 μg L-1 to 2000 μg L-1 to triadimenol, tebuconazole and metconazole, with LQ of 100 μg L-1. For water analysis, the analytical range of the method comprises from 100 μg L-1 to 3000 μg L-1, with LQ of 100 μg L-1.The proposed method for triazole analyses in grape juice met all required specifications being applied with confidence. However, the detectability of the method was insufficient for the analyses of triazoles in water samples due to the low tolerance limits. / Fundação de Amparo à Pesquisa do Estado de Minas Gerais - FAPEMIG
|
10 |
Síntese de um polímero de impressão molecular restrito à ligação com macromoléculas por meio de revestimento com albumina (RAMMIP-BSA), para análise direta de clorpromazina em plasma por sistema de cromatografia líquida bidimensionalMORAES, Gabriel de Oliveira Isac 23 July 2012 (has links)
Um polímero de impressão molecular restrito à ligação de macromoléculas por
meio de revestimento com albumina (do inglês “restrict access moleculary imprinted
polymer coated with albumine” – RAM-MIP-BSA) foi sintetizado para a análise de
clorpromazina em plasma humano por injeção direta em cromatografia líquida
bidimensional. Primeiramente foram colocados no meio reacional o ácido metacrílico
como monômero funcional, o etileno glicol dimetacrilato como agente de ligação
cruzada, a 2,2 – azo isobutironitrila como iniciador radicalar, a clorpromazina como
molécula modelo e o clorofórmio como solvente. O sistema foi mantido sob agitação
por 60 minutos a 60°C. Depois, adicionou-se ao meio reacional hidróxi etil metacrilato
e glicidil metacrilato como monômeros hidrofílicos. Após 24 h o polímero foi recolhido,
lavado, tamisado e recoberto com albumina utilizando-se glutaraldeído como agente
reticulante bifuncional. O RAM-MIP-BSA foi empacotado em uma pré-coluna de HPLC
(high performance liquid chromatography) de 1 cm e sua capacidade de eliminação
de macromolécula foi testada obtendo-se eliminação superior a 99%. Para os demais
testes a pré-coluna foi utilizada em sistema de cromatografia líquida bidimensional. A
amostra é injetada e as macromoléculas são eliminadas enquanto o analito é retido.
Num segundo estágio o analito é eluído e conduzido para coluna analítica. Água ultrapura
e uma solução de acetonitrila:tampão acetato de sódio 0,2 mol L-1 pH 4,1 45:55
(v/v) foram empregadas como fase de extração e fase móvel respectivamente. As
análises foram executadas utilizando-se um detector UV/Vis a 313 nm. Para validação
analítica da clorpromazina foi utilizando um pool de amostra de plasma humano de
diferentes indivíduos voluntários, fortificadas em oito níveis de concentração,
contemplando assim o intervalo terapêutico de 50-300 μg L-1 segundo a FDA. O
método foi linear na faixa de 30-350 μg L-1, com r > 0,99 e limite de quantificação de
30,0 μg L-1. A precisão e exatidão intra-dias e inter-dias foram avaliadas com base no
desvio padrão relativo (DPR) e no erro relativo (E) respectivamente e todos os
resultados foram inferiores a 15% de acordo com a FDA. A recuperação foi de 80%. / A restrict access moleculary imprinted polymer coated with albumin (RAM-MIPBSA)
has been synthesized and used for direct analysis of chlorpromazine from human
plasma by using bidimensional liquid chromatography. The synthesis was carried out
in three steps. First, methacrylic acid (functional monomer), ethylene glycol
dimethacrylate (cross-linker), 2,2 azoisobutironitrile (initiator) and chlorpromazine were
dissolved in chloroform and the mixture was maintained at 60°C during 60 min. In the
second step, 2-hydroxy ethyl acrylate and glycidil (both hydrophilic co-monomers)
were added into the flask and the synthesis was processed during 24h at 60°C. The
obtained polymer was washed several times and coated with bovine serum albumin
by using glutaraldehide as cross-linker. The material presented a macromolecules
elimination ability larger than 99%. It was packed in a column (4.4 x 10 mm) and used
in a column switching system. Deionized water and 45:55 (v/v) acetonitrile:sodium
acetate buffer (pH=4.1) were employed as extraction solvent and mobile phase,
respectively. The analytical curve was built using a human plasma pool of different
volunteers, added with the drug in 8 different concentrations. The method has shown
to be linear in the range from 30 to 350 mg L-1, with r >0.99 and quantification limit of
30 mg L-1. Precision and accuracy were evaluated by using relative standard deviation
and relative error, respectively, and all the results are in accordance with FDA
recommendations. Additionally, good recoveries and selectivity were also obtained.
|
Page generated in 0.6435 seconds