Spelling suggestions: "subject:"inomhus.""
1 |
Multi-dimensional approach used for energy and indoor climate evaluation applied to a low-energy building /Karlsson, Fredrik, January 2006 (has links)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2006. / Härtill 7 uppsatser.
|
2 |
Klimatsimulering av nybyggnationEngvall, David January 2008 (has links)
<p>Detta examensarbete på C-nivå har genomförts i samarbete med ÅF Infrastruktur AB, Borlänge och syftar till att simulera inomhusklimatet för valda delar inom nybyggnation Experium, Lindvallen samt med hjälp av simuleringarna beräkna effekt- och energibehovet för dimensionering av en fjärrvärmeinstallation alternativt installation av elpanna samt kylcentral.</p><p>ÅF Infrastruktur AB har uppdragen installationsprojektering samt installationsledning åt beställaren Skistar som skall upprätta Experium. Vilket skall resultera i en upplevelsearena på 17 000 m2 innehållande äventyrsbad, bowlinghall, eventyta samt restauranger mm.</p><p>Författarens uppgift är att hjälpa ÅF Infrastruktur AB att klimatsimulera eventytan samt bowlinghallen på Experium med ett typiskt dygnsförlopp i beaktande. Då speciellt kolla på operativa temperaturer, relativa fuktigheter samt koldioxidnivån som uppstår i respektive lokal. För dessa simuleringar har datorprogrammet IDA Klimat & Energi 3,0 använts.</p><p>Simuleringen av ett typiskt dygnsförlopp på eventytan med 3000 personer samtidigt i lokalen på en afterski eller konsert, samt efterföljande 1500 samtidigt sittande personer skall resultera i om projekterat flöde räcker för att upprätthålla ett behagligt inomhusklimat. Simuleringen visar på att 3000 personer på samma gång är i översta laget, 1500 personer är mera realistiskt.</p><p>Simuleringen av bowlinghallen syftar till att utreda om den relativa fuktigheten som ett bowlinggolv kräver, normalt 40-50 %, upprätthålls utan befuktare under vinterhalvåret. Det visar sig att under vinterhalvåret ligger den relativa fuktigheten på 20-30 %, en befuktare krävs för att upprätthålla den relativa fuktigheten på 40-50 %.</p><p>En effekt- och energibehovsberäkning omfattande transmissions-, ventilations- och poolförluster samt energiåtgången för uppvärmning av tappvarmvatten skall tas fram som underlag för dimensionering av uppvärmningssystemet. Resultatet av dessa beräkningar blev att uppvärmningssystemet bör klara av 1,4 MW.</p><p>Simuleringar och beräkningar tas upp under kapitlet resultat och slutsats, beräkningarna återfinns sedan i bilagorna.</p> / <p>This diploma work has been performed in cooperation with ÅF Infrastruktur AB in Borlänge, Sweden, and aims to simulate the indoor climate for specific parts at the new erected Experium in Lindvallen. It also aims to estimate the power- and energy demand for installation of district heating or an electric boiler and a cooling centre.</p><p>ÅF Infrastruktur AB has installation planning and installation management for the orderer Skistar who shall establish Experium. Experium is an experience arena on 17 000 m2 which will comprise an adventure bath, bowling hall and restaurants etc.</p><p>The author’s assignment is to help ÅF Infrastruktur AB to simulate the climate in the “Eventytan” which is a restaurant, and the bowling hall on Experium, with consideration of a typical diurnal course and specially check out the operating temperatures, relative moisture and the carbon dioxide levels which occur in the building. This climate simulation has been carried out in the computer program IDA Indoor Climate and Energy 3,0.</p><p>The simulation of a typical diurnal course with 3000 persons at the same time in “Eventytan” and following 1500 persons shall answer the question if project supply flow will manage to sustain a pleasant indoor climate. The simulation shows that 3000 persons at the same time in “Eventytan” are slightly too much. 1500 persons is more a realistic point of view.</p><p>The simulation of the bowling hall is too investigate if the relative moisture level which the floor of bowling halls demands, normally 40-50 % to maintain without an humidifier on the winter month. The results of the simulation shows that under the winter month the relative moisture level is approximately 20-30 % which is too low, so the conclusion is that a humidifier is needed.</p><p>A power- and energy demand calculation extensive transmission-, ventilation- and pool losses also contains the energy consumption for heating hot water. This basic data underlie as decision –making for heating up the building. The result of this show a demand of 1,4 MW.</p><p>Simulations and calculations brings up under the result chapter and conclusion chapter, the calculations can be recovered back in the appendix.</p>
|
3 |
Klimatsimulering av nybyggnationEngvall, David January 2008 (has links)
Detta examensarbete på C-nivå har genomförts i samarbete med ÅF Infrastruktur AB, Borlänge och syftar till att simulera inomhusklimatet för valda delar inom nybyggnation Experium, Lindvallen samt med hjälp av simuleringarna beräkna effekt- och energibehovet för dimensionering av en fjärrvärmeinstallation alternativt installation av elpanna samt kylcentral. ÅF Infrastruktur AB har uppdragen installationsprojektering samt installationsledning åt beställaren Skistar som skall upprätta Experium. Vilket skall resultera i en upplevelsearena på 17 000 m2 innehållande äventyrsbad, bowlinghall, eventyta samt restauranger mm. Författarens uppgift är att hjälpa ÅF Infrastruktur AB att klimatsimulera eventytan samt bowlinghallen på Experium med ett typiskt dygnsförlopp i beaktande. Då speciellt kolla på operativa temperaturer, relativa fuktigheter samt koldioxidnivån som uppstår i respektive lokal. För dessa simuleringar har datorprogrammet IDA Klimat & Energi 3,0 använts. Simuleringen av ett typiskt dygnsförlopp på eventytan med 3000 personer samtidigt i lokalen på en afterski eller konsert, samt efterföljande 1500 samtidigt sittande personer skall resultera i om projekterat flöde räcker för att upprätthålla ett behagligt inomhusklimat. Simuleringen visar på att 3000 personer på samma gång är i översta laget, 1500 personer är mera realistiskt. Simuleringen av bowlinghallen syftar till att utreda om den relativa fuktigheten som ett bowlinggolv kräver, normalt 40-50 %, upprätthålls utan befuktare under vinterhalvåret. Det visar sig att under vinterhalvåret ligger den relativa fuktigheten på 20-30 %, en befuktare krävs för att upprätthålla den relativa fuktigheten på 40-50 %. En effekt- och energibehovsberäkning omfattande transmissions-, ventilations- och poolförluster samt energiåtgången för uppvärmning av tappvarmvatten skall tas fram som underlag för dimensionering av uppvärmningssystemet. Resultatet av dessa beräkningar blev att uppvärmningssystemet bör klara av 1,4 MW. Simuleringar och beräkningar tas upp under kapitlet resultat och slutsats, beräkningarna återfinns sedan i bilagorna. / This diploma work has been performed in cooperation with ÅF Infrastruktur AB in Borlänge, Sweden, and aims to simulate the indoor climate for specific parts at the new erected Experium in Lindvallen. It also aims to estimate the power- and energy demand for installation of district heating or an electric boiler and a cooling centre. ÅF Infrastruktur AB has installation planning and installation management for the orderer Skistar who shall establish Experium. Experium is an experience arena on 17 000 m2 which will comprise an adventure bath, bowling hall and restaurants etc. The author’s assignment is to help ÅF Infrastruktur AB to simulate the climate in the “Eventytan” which is a restaurant, and the bowling hall on Experium, with consideration of a typical diurnal course and specially check out the operating temperatures, relative moisture and the carbon dioxide levels which occur in the building. This climate simulation has been carried out in the computer program IDA Indoor Climate and Energy 3,0. The simulation of a typical diurnal course with 3000 persons at the same time in “Eventytan” and following 1500 persons shall answer the question if project supply flow will manage to sustain a pleasant indoor climate. The simulation shows that 3000 persons at the same time in “Eventytan” are slightly too much. 1500 persons is more a realistic point of view. The simulation of the bowling hall is too investigate if the relative moisture level which the floor of bowling halls demands, normally 40-50 % to maintain without an humidifier on the winter month. The results of the simulation shows that under the winter month the relative moisture level is approximately 20-30 % which is too low, so the conclusion is that a humidifier is needed. A power- and energy demand calculation extensive transmission-, ventilation- and pool losses also contains the energy consumption for heating hot water. This basic data underlie as decision –making for heating up the building. The result of this show a demand of 1,4 MW. Simulations and calculations brings up under the result chapter and conclusion chapter, the calculations can be recovered back in the appendix.
|
4 |
Visualization of airflow, temperature and concentration indoors : whole-field measuring methods and CFD /Cehlin, Mathias, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Tekniska högskolan, 2006. / Härtill 7 uppsatser.
|
5 |
Energieffektiv ventilation / Energyefficient ventilationFjellborg, Anders January 2012 (has links)
Syftet med detta examensarbete är att konkretisera och visa på de grundläggande problemen med inomhusklimatet i Brogårdsfabriken i Vetlanda, för att utifrån detta komma fram med åtgärdsförslag för att minska dem. Detta samt att utreda möjligheterna att ta till vara den i fabriken internt genererade överskottsvärmen och minska energianvändningen. Arbetet har skett i ett top-down-perspektiv, vilket betyder att fabriken ses som ett slutet system där tillförd energi in i systemet ställs mot bortförd energi ut ur systemet. Stor del av arbetet har bedrivits i simuleringsprogrammet IDA – Indoor Climate and Energy till vilket data samlats in genom fysiska mätningar i fabriken och genom intern dokumentation på företaget. Problemen med inomhusklimatet för de anställda ute i produktionen är av olika karaktär i olika delar av fabriken och varierar även i intensitet beroende på vilken tid på året som studeras. Dock är de bakomliggande orsakerna till problemen alltid desamma. Det handlar bland annat om bristfällig processventilation, stora öppna lokaler som är svårkontrollerade, problem med infiltration genom portar och andra öppningar i klimatskalet. Förslag att återskapa en tidigare befintlig vägg rekommenderas för att lösa problemet med kalldrag i packhallen. Väggen skulle förhindra luftrörelser i områden där problemen upplevs och nästintill eliminera dem. Fokus på att minska energianvändningen har skett genom att titta på en optimering av ventilationsdriften vilket har resulterat i en kostnadsbesparing på cirka 370 tkr/år vid reducering av driften under enbart helger. Det finns ytterligare potential till kostnadsbesparingar för ventilationsdriften under andra tillfälliga driftstopp eller semesterstängningar av fabriken, om ventilationsdriften anpassas efter detta.
|
6 |
CFD-simulering av kallras från fönster : Konvektorers och nischdjupets inverkan på lufthastigheter i rummet / CFD simulation of cold air downdraughts from windowsEmil, Svensson January 2014 (has links)
During cold winter days it is likely that people in buildings with older windows or high glass facades experience thermal discomfort due to cold air down draughts. Earlier work has been aimed at finding analytical methods to predict the speed of the airflow in a room and in practice heating appliances are often placed beneath the windows to reduce the draught along the floor. In a study from 2012 Mohammad Parchami developed a method for estimating the required heating power to counteract the downdraught with such heating appliances. In this study, Computational Fluid Dynamics (CFD) was used to evaluate the usefulness of Parchami’s method and also to examine the potential of adapting the depth of the inward window sill as a means of decreasing the down draught. The result suggested that Parchami’s method is in need of certain modifications and further CFD-simulations can be a useful tool to make the method more acceptable to the building profession. Further, it was also shown that an adapted sill depth could considerably reduce the airflow speed in the room and the result indicated that there is an “effective sill depth” at which the airflow speed from the downdraught reaches a minimum. It is likely that this effective sill depth in large part depends on the boundary layer thickness at the window, in which case the constructors are given the alternative to determine the window sill depth by an easy estimation of the boundary layer thickness.
|
7 |
Förbättrat inomhusklimat med lägre energiförbrukning i öppet kontorslandskap : Ventilationens påverkan på inomhusklimatet och termisk komfortChristopher, Magnusson January 2019 (has links)
Idag spenderas en stor del av vår tid inomhus, det ställer krav på inomhusluften. Koldioxid och andra föroreningar, som stannar i luften vid dåligt ventilerade lokaler, påverkar negativt och är bevisat att påverka prestationen och produktiviteten hos människor i specifika uppgifter. Idag läggs mycket fokus på miljösmarta lösningar och effektiviseringar, men ibland glöms inomhusklimatet bort. För att människor ska få en behaglig upplevelse av inomhusklimatet krävs kvalité på inomhusluften men också på den termiska komforten. Huvudsyftet med examensarbetet är att förklara hur det går att uppnå förbättrat inomhusklimat och samtidigt minska energiförbrukningen. Genom att minska energibehovet kan företag bli mer konkurrenskraftiga och samtidigt rusta sig mot de stigande elpriserna. Det finns även en ekonomisk fördel för företag såväl som för privata bostäder. Examensarbetet består utav en fallstudie, där luftenstemperatur och fuktighet kommer at loggas och data genereras. Loggning kommer att ske vid två tillfällen. Först i början för att få en uppfattning om varför personalen upplever dåligt inomhusklimat och sedan efter justering av luftflödena för att se skillnaden i förändringen av inomhusklimatet och energipåverkan. Genom att justera systemet och sammanställa resultat har forskningsfrågan ”Kan inomhusklimatet förbättras samtidigt och samtidigt minska energiförbrukningen?” besvarats. Litteraturstudien visar att om alternativa ventilationsprinciper används, istället för det konventionella omblandande systemet, går det att minska energiförbrukningen samtidigt som inomhusklimatet förbättras. Detta har gjorts genom att golvventilation använts där tilluften tillförts lågt och undertempererad för att luften ska stiga genom de termiska krafterna. Resultatet visar att termisk komfort försämrats enligt enkätstudierna, men samtidigt visar det en förbättring av inneklimatet i enskilda frågor. Mätresultaten indikerar även på förbättrad ventilation och inomhusklimat. Slutligen presenterades energibesparingsåtgärder som företaget kan göra för att minska energibehovet och samtidigt förbättra den termiska komforten.
|
8 |
Energikartläggning av Masurgårdens förskola : Åtgärder och dess potentiella energi- och kostnadsbesparingLindberg, Joakim January 2014 (has links)
Arbetet syftar till att åskådliggöra energianvändningen i Masurgårdens förskola samt kontrollera om fastighetens energisystem används optimalt. Kartläggningen syftar till att förse fastighetsägaren med beslutsunderlag för framtida investeringskalkyler och energi-besparingsåtgärder.En modell av fastigheten skapades i energisimuleringsprogrammet IDA ICE, klimat-skalet återskapades från konstruktionsritningar, belysning och personbelastning inven-terades på plats. Resterande indata var baserat på nyckeltal från tidigare studier och schablonvärden.Simuleringsresultaten visar att fastigheten inte är i behov av några större investeringar i energibesparande åtgärder. Men det konstateras att en årlig energibesparing på 5308 kWh (5,6 %) är möjlig genom en sänkning av uteluftsflöde under vintermånaderna och genom att byta ut radiatortermostaterna mot nya. Åtgärderna leder även till en förbättring av inomhusmiljön och tros minska problemen med torra slemhinnor under vintermånaderna hos brukarna. / This work aims to illustrate the use of energy in Masurgårdens förskola and verify that the property's energy is used optimally. The survey seeks to provide the landlord with decision support for future investment calculations and energy saving measures.A model of the building is created in the energy simulation program IDA ICE, the building envelope was recreated from the buildings blueprints, lighting and personal load was inventoried. The remaining input data were taken from previous studies or from standard values.Simulation results show that the building is not in need of significant investment in energy saving measures. But it is found that annual energy savings of 5308 kWh (5.6%) is possible by lowering the outdoor airflow during winter months and by replacing the radiator thermostats with new ones. The measures also leads to an improvement of indoor environment and is believed to reduce the problem with mucosal dryness on the buildings occupants during the winter months.
|
9 |
Utvärdering av energianvändningen i kv Blå JungfrunKorkut, Bayram, Elfar, Hussam January 2012 (has links)
Utvärdering av energianvändningen i KV. Blå Jungfrun Sammanfattning Byggsektorn står idag för en stor del av Sveriges totala energianvändning. Den största mängden av energin används i driftfasen för bland annat uppvärmning. Att minska energianvändningen för uppvärmningen av bostäder är alltså viktigt. Därför har intresset för energieffektivisering i byggnader ökat betydligt på senare tid. Passivhustekniken innebär att hus byggs utan konventionella värmesystem. Genom ett välisolerat och tätt klimatskal i kombination med ett effektivt ventilationssystem tillvaratas värme passivt från människor, elektriska apparater och solinstrålning. Vid eventuellt kallt inomhusklimat kan komplementvärme som distribueras med el, vatten eller luft användas. Denna rapport behandlar uppföljning av energianvändningen i fyra lamellhus med passivhusteknik i Hökarängen, som är byggda av Skanska på uppdrag av Svenska bostäder. Kvarteret benämns "Blå jungfrun" och består av 97 hyreslägenheter. Efter ett års mätdata från 2011 har det visat sig att varmvattenförbrukningen och användningen av komplementvärmen inte motsvarat förväntningarna. Utifrån intervjuer med hyresgästerna och delaktiga i projekteringen, samt befintlig mätdata på temperaturer, komplementel och hushållsel har dessa avvikelser undersökts. Resultaten från intervjuerna och data analyserades sedan med hjälp av en teoretisk referensram från en tidigare gjord litteraturgranskning. För att uppnå bästa möjliga energieffektivisering är det viktigt att alla inblandade parter tar sitt ansvar, allt från projektering till att byggnaden sätts i drift. Alltså har brukaren ett stort ansvar i driftfasen. Genom utvärdering av resultat har det visat sig att miljömedvetenhet och livsstil hos hyresgästen har stor inverkan på förbrukningen av varmvatten, samt toleransen till ett kallare inomhusklimat vilket påverkar förbrukning av komplementelen. Andra faktorer där hyresgästens roll har mindre betydelse för avvikelserna är: Kalla golv på bottenvåningen Bättre temperaturer på övervåningen Missvisande hyresavdrag på varmvatten "Dåligt" optimerad varmvattencirkulation
|
10 |
Energieffektivisering utav Centralgaraget i VitåforsSongsong, Marcus January 2024 (has links)
LKAB är ett företag som satsar på att minimera sin klimatpåverkan bland annat genom att elektrifiering och energieffektivisering av deras anläggningar. Centralgaraget på Malmberget är en fastighet byggd 1958 som huserar en rad olika fordon så som bilar och bussar men även har verkstäder och kontor. Syftet med arbetet har varit att ge underlag åt LKAB för möjliga investeringar i åtgärder för energieffektivisering och förbättring av inomhusklimat. Genom att först bygga en energimodell av byggnaden och sedan simulera olika förslag samt att beräkna dessa ekonomiskt kunde underlaget skapas. Med givna data från LKAB för fjärrvärmeförbrukningen mellan åren 2018 och 2023 togs ett min-, medel- och maxvärde på års- och månadsbasis. Intervallet blev 292 −574 𝑀𝑊ℎ/å𝑟 och medelvärdet 412 𝑀𝑊ℎ/å𝑟. Basfallet som gjordes för att efterlikna verkligheten hade en simulerad fjärrvärmeförbrukning på 540 𝑀𝑊ℎ/å𝑟. Förbrukningen för de simulerade förslagen kan delas upp i tre grupper. Den första gruppen är de med variabel flödesventilation (VAV) i hallarna och verkstäderna samt en simulering med VAV i hela byggnaden som fick värdena 395 𝑀𝑊ℎ/å𝑟 respektive 386 𝑀𝑊/å𝑟ℎ. Andra gruppen var byte av fönster till ett genomsnittligt värmegenomgångstal på 𝑈 = 0,9 𝑊𝑚2𝐾 och tillägget av markiser vilka hade 532 𝑀𝑊ℎ/å𝑟 för byte av fönster och 527 𝑀𝑊ℎ för tillägget av markiser. Sista gruppen var simuleringarna med golvvärme i garaget med effekten per kvadratmeter 20 ,40 samt 40 i kombination med befintliga fläktaggregat. Dessa hade en förbrukning på 550 𝑀𝑊ℎ/å𝑟, 580 𝑀𝑊ℎ/å𝑟 samt 586 𝑀𝑊ℎ/å𝑟. Elförbrukningen kunde grupperas likadant som för fjärrvärmeförbrukningen där värdet var 99 𝑀𝑊ℎ/å𝑟 för Basfallet och en variation mellan 59 − 99 𝑀𝑊ℎ/å𝑟 för resten av simuleringarna. Enligt offert från Frico AB var besparingen i 𝑀𝑊ℎ/å𝑟 mellan 10,6 − 16,2 𝑀𝑊ℎ/å𝑟 per aggregat beroende på vilken hall som de var installerade i. Elkedjans solcellskalkylator gav en elproduktion på 43𝑀𝑊ℎ/å𝑟 Inomhusklimatet evaluerades efter Fangers modell där PPD värdet varierade mellan 18 − 23% där simuleringarna med Markiser och VAV i hela byggnaden hade bäst värden och byte av fönster det dåligaste. Baserat på resultaten simulerades två kombinationsförslag där den ena hade VAV i hallarna och markiser medan det andra också hade golvvärme. Dessa hade fjärrvärmeförbrukningen och PPD värde 410 𝑀𝑊ℎ/å𝑟 och 19% respektive 440 𝑀𝑊ℎ/å𝑟 och 17%. Elförbrukningen var 46 𝑀𝑊ℎ/å𝑟 respektive 61 𝑀𝑊ℎ/å𝑟. De ekonomiska kalkylerna visade att luftridåerna hade en återbetalningstid på 10 −15 år och en internränta mellan 1 − 13%. Samtliga förslag förutom solpaneler och fönsterbyte var positiva investeringar med en återbetalningstid mellan 1,3 − 8 år och en internränta mellan 9 − 51%. Rekommendationen till LKAB blev att investera i luftridåer i fyra utav hallarna samt att implementera VAV i hallarna, lägga till markiser och börja använda golvvärmen. Energiförbrukningen för detta fall ger en minskning på 153 𝑀𝑊ℎ/å𝑟 relativt Basfallet exklusive luftridåerna och har det bästa inomhusklimatet. Återbetalningstiden för detta är 1,6 år med en internränta på 14%. Detta fall ger en både det bästa inomhusklimatet samt en relativt stor energibesparing.
|
Page generated in 0.0341 seconds