• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 561
  • 9
  • 8
  • 8
  • 8
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 572
  • 569
  • 266
  • 247
  • 185
  • 101
  • 95
  • 85
  • 84
  • 77
  • 74
  • 74
  • 68
  • 52
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
511

Avaliação de misturas injetáveis aplicadas à fabricação de micro componente para pinças de biópsias por moldagem de pós por injeção

Tavares, André Carvalho January 2014 (has links)
A moldagem de pós por injeção (MPI) foi empregada neste trabalho para a fabricação de micro componentes de uma pinça de biópsia, através do desenvolvimento de misturas injetáveis. Utilizou-se a liga de aço inoxidável AISI 316L, liga reconhecidamente biocompatível, para obtenção dos micro componentes. Determinando a quantidade de 39% em volume para fração orgânica das quatro formulações de misturas injetáveis produzidas neste trabalho. Os polímeros estruturais empregados foram o PP, o PEBDL, o PEAD e o PMMA. Como material auxiliar de fluxo foi utilizada a parafina e para agente surfactante, o ácido esteárico. O desenvolvimento do sistema de extração química do polímero auxiliar de fluxo com solvente e posterior extração térmica do ligante em forno convencional e em um reator a plasma foram testados, ainda se empregou estes para testes em sinterização a temperaturas 1200°C, 1250°C e 1300°C. A extração química foi realizada com hexano atingindo 2,41% em massa de material extraído das amostras, após seis horas em um sistema aquecido entre 60°C e 70°C e uma atmosfera de vácuo. As amostras foram testadas química, física, mecânica e eletroquimicamente. Obteve-se os melhores resultados em termos de densificação de 7,05 g/cm³ para as amostras extraídas a plasma e sinterizadas a 1300 °C à vácuo em forno tubular. Isso significa uma densificação de 88,96% comparada a densidade do material comercial cuja a densidade é 7,93 g/cm³. As microdurezas encontradas nas amostras sinterizadas a 1300 °C em um forno convencional obtiveram valores de 208HV se mostrando maiores do que os 165HV obtido de um material maciço fabricado pelo extrusão e comercialmente vendido. Encontrou-se a dureza de 55HRB nas amostras processadas a 1300 °C, devido a presença de poros em componentes sinterizados. Nos componentes maciços foram medidos a dureza de 88HRB que foi maior que os resultados das amostras sinterizadas. As análises metalográficas mostraram um tamanho de grão variando entre, 30 e 50μm, se comparado ao tamanho de partícula médio do D90 de foi de 8,59 μm, se estima que este aumento foi entorno de três vezes e meia. Os testes químicos revelaram que a extração térmica em reatores a plasma melhoram significativamente os níveis de C, N, H e S quando comparados ao processo de extração térmica em forno convencional. A redução dos níveis de carbono residual, resultaram em diminuição do carboneto de cromo nas amostras, provocando uma menor corrosão. As amostras sinterizadas a 1200 °C a plasma apresentaram os melhores resultados de corrosão. / The powders injection molding (PIM) was used in this research, with objective to manufacture micro component, for application in biopsy forceps being developed injectable mixtures . It was used the powder stainless steel AISI 316L alloy, material biocompatible, to obtain the micro components. Through tests was determining the amount optimal volume in 39 % for the organic fraction of the four formulations of injectable mixtures produced in this research. The structural polymers used were PP , LLDPE , HDPE and PMMA . The paraffin was used as auxiliary material flow, the surfactant agent employed that was stearic acid . The development of chemical debiding and the thermal extraction for binder system, was used the conventional furnace and in a plasma reactor were tested also be employed for these tests sintering temperature 1200 ° C , 1250 °C and 1300 °C. Chemical extraction was performed with hexane achieving 2.41 % by extracted mass of sample material, after six hours in a heated system between 60 °C and 70 °C and a vacuum atmosphere. The samples were tested analysis by chemical , physical , mechanical and electrochemical.If it obtained the best results in terms of densification of 7.05g/cm ³ for plasma samples extracted and sintering at 1300 °C in vacuum tube furnace . This means densification of 88.96 % compared to the density of commercial material whose density is 7.93 g/cm ³ . The microhardness found in the samples sintered at 1300°C in a conventional furnace obtained 208HV microhardness showing larger than the commercial 165HV. Found that the HRB hardness of 55 in the samples processed at 1300 °C, due to the presence of pores in sintered parts. In the extruded components were measured hardness of 88HRB which was higher than the results of the sintered samples. The metallographic analysis showing a grain size ranging between 30 and 50μm , compared to the average particle size D90 was 8,59 microns is estimated that this increase was around three and half times . The chemical tests revealed that the thermal plasma extraction reactor significantly improve the levels of C, N , H and S compared to the process heat extraction in a conventional furnace . The residual carbon levels significantly improved, which helps to avoid the formation of chromium carbides , which aumnetou corrosion resistance . The best results in terms of corrosion were found for the samples sintered at 1200 ° C the plasma.
512

Estudo do processo de estampagem para materiais alternativos na fabricação de um componente para a indústria de máquinas agrícolas

Bau, Atilano Roberto January 2015 (has links)
No presente trabalho, a conformabilidade do aço inoxinoxidável AISI 201 foi comparada com o aço inoxidável AISI 304. O aço inoxidável AISI 201 é uma liga baixo níquel ligado com manganês e nitrogênio. Nesse estudo a conformabilidade dos dois materiais foi examinada por meio de ensaios tecnológicos como ensaio de tração, determinação da curva de escoamento, determinação do índice de anisotropia, ensaio Erichsen, dureza, composição química, simulação computacional do processo de estampagem e estampagem dos blanks. O aço inoxidável AISI 201 possui propriedades como limite de escoamento e tensão de ruptura superior as do inoxidável AISI 304. Os dois aços possuem uma similaridade na anisotropia. A máxima altura alcançada no momento da fratura pelo ensaio Erichsen também é semelhante para os dois materiais. O aço inox AISI 201 apresenta uma dureza maior que o inoxidável AISI 304. Na composição química os dois aços apresentam elementos fora do especificado, caracterizando um problema de qualidade na fabricação desses aços. A simulação computacional do processo de estampagem apresentou uma redução de espessura na região mais critica, sem comprometer a estampagem do componente. Uma vez estampadas, obteve-se peças sem indícios de trincas, conforme previsto pela simulação computacional. Os resultados desse trabalho sugerem a possibilidade de utilização do aço inoxidável AISI 201 como opção para substituição ao inoxidável AISI 304, tendo uma observação a ser feita quanto aos cuidados na qualidade durante a fabricação do aço para que atenda os padrões exigidos. / In this study, the formability of stainless steel AISI 201 was compared to stainless steel AISI 304 stainless steel AISI 201 is a low alloy nickel alloyed with manganese and nitrogen. In this study, the formability of the two materials was examined by means of technological tests such as tensile test, determination of the flow curve, determining the anisotropy index, Erichsen test, hardness, chemical composition, computer simulation of the stamping process and stamping of the blanks. Stainless steel AISI 201 has properties such as yield strength and higher breakdown voltage of the stainless steel AISI 304. The two steels have a similarity in anisotropy. The maximum height reached at the time of fracture by Erichsen test is also similar for the two materials. Stainless steel AISI 201 has a hardness greater than the stainless steel AISI 304. In chemistry the two steels have elements outside the specified, featuring a quality problem in manufacturing these steels. A computer simulation of the printing process showed a reduction in thickness in the most critical region, without compromising the component stamping. Once stamped, gave no broken pieces of evidence as provided by the computer simulation. The findings suggest the possibility of use of stainless steel AISI 201 as an option to replace the stainless steel AISI 304, with a point to be made about the care as during the manufacture of steel that meets the required standards.
513

Análise microestrutural de revestimentos aplicados para o reparo de turbinas hidráulicas erodidas por cavitação / Microstructural analysis of coatings applied to the repair of hydraulic turbines eroded by cavitation

Gomide, Danilo Antônio 27 July 2018 (has links)
Submitted by Danilo Gomide (gomidedanilo@gmail.com) on 2018-09-25T01:29:16Z No. of bitstreams: 1 Dissertação-Danilo Gomide.pdf: 5902894 bytes, checksum: 200b6aa57360f837a89107b0b9e766f0 (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-09-25T18:54:18Z (GMT) No. of bitstreams: 1 gomide_da_me_ilha.pdf: 5902894 bytes, checksum: 200b6aa57360f837a89107b0b9e766f0 (MD5) / Made available in DSpace on 2018-09-25T18:54:18Z (GMT). No. of bitstreams: 1 gomide_da_me_ilha.pdf: 5902894 bytes, checksum: 200b6aa57360f837a89107b0b9e766f0 (MD5) Previous issue date: 2018-07-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A cavitação ocorre inerente ao processo de produção de energia elétrica nas Usinas Hidrelétricas, ocasionando perda progressiva de massa, afetando o desempenho e potência obtidos das turbinas hidráulicas, sendo necessário o seu reparo. Visando minimizar desgaste utiliza-se uma técnica de engenharia de superfície que é aplicar uma camada de material resistente a cavitação. Dentre esses materiais destacam-se os aços inoxidáveis com cobalto, por causa de sua dureza, baixa energia de falha de empilhamento e capacidade de endurecimento por deformação. As deposições desses materiais são realizadas por processos de soldagem, como a soldagem a arco elétrico com atmosfera gasosa ou por soldagem com arame tubular, devido ao baixo custo, elevada taxa de deposição, qualidade de acabamento superficial e baixa taxa de diluição. Diante deste contexto, esse trabalho foi realizado para analisar a camada de aço inoxidável austenítico com cobalto e verificar a influência da camada de amanteigamento. Sendo assim, foram produzidas duas séries de amostra, cada uma composta por três corpos de provas, sendo diferenciadas pela energia de soldagem utilizadas no processo, obtidas pela variação da corrente de soldagem, 98 A, 143 A e 198 A. Na primeira série foi simulado uma condição de reparo das turbinas hidráulicas, utilizando como metal base o aço ASTM A36, sendo depositado sobre ele o arame AWS E70-S6, como camada de preenchimento, posteriormente foi aplicado o arame AWS E309-T1, camada de amanteigamento, e por último foi depositado o aço inoxidável austenítico com cobalto, como revestimento. Na segunda série as amostras foram produzidas sem a camada de amanteigamento. A microestrutura foi analisada por macrografia e microscopia eletrônica de varredura. Os resultados mostraram boa interação metalúrgica entre as diferentes camadas e microconstituintes correspondentes aos investigados na literatura. A microanálise por EDS demonstra a baixa diluição do processo de soldagem utilizado. Os ensaios de difração de raio-X foram capazes de identificar as estruturas de cada camada, como a estrutura CFC no material resistente a cavitação. O ensaio de microdureza instrumentado demostra a capacidade de o revestimento com cobalto resistir à cavitação e que é dispensável a camada de amanteigamento. / Cavitation occurs inherently to the process of production of electric power in the Hydroelectric Power Plants, causing progressive loss of mass, affecting the performance and power obtained from the hydraulic turbines, being necessary its repair. In order to minimize wear, a surface engineering technique is used to apply a layer of cavitation resistant material. Among these materials stand out the cobalt stainless steels, because of their hardness, low stacking failure energy and strain hardenability. The depositions of these materials are carried out by welding processes, such as Gas Metal Arc Welding or by Flux Cored Arc Welding, due to the low cost, high deposition rate, surface finish quality and low dilution rate. Considering this context, this work was carried out to analyze the austenitic stainless steel layer with cobalt and to verify the influence of the buttery layer. Therefore, two series of samples, each composed of three test bodies, were differentiated by the welding energy used in the process, obtained by the variation of the welding current, 98 A, 143 A and 198 A. In the first group, a hydraulic turbine repair condition was simulated using ASTM A36 steel as the base metal. The AWS E70-S6 wire was deposited on it as a fill layer, after which the AWS E309-T1 wire was applied. and finally the austenitic stainless steel with cobalt was deposited as a coating. In the second group of samples were produced without the buttery layer. The microstructure was analyzed by macrography and scanning electron microscopy. The results showed good metallurgical interaction between the different layers and microconstituents corresponding to those investigated in the literature. Microanalysis by EDS demonstrates the low dilution of the welding process used. The X-ray diffraction tests were able to identify the structures of each layer, such as the CFC structure in the cavitation resistant material. The instrumented microhardness test demonstrates the ability of the cobalt coating to withstand cavitation and that the buttery layer is dispensable.
514

Morfometria comparativa in vitro do desgaste dentinário do terço cervical de raízes mésio-vestibulares de primeiros molares superiores produzido por instrumentos rotatórios de aço e de níquel-titânio / In vitro morphometric study of cervical third dentin wearing in upper molar mesiobuccal roots after preparation with iron burs and rotary nickel-titanium instruments

Júnio Pereira de Sá 30 October 2002 (has links)
No preparo dos canais radiculares, eminentemente os curvos, a abordagem cérvico-apical amplamente difundida promovendo a dilatação da região cervical do canal radicular previamente à atuação de instrumentos em sua região apical constitui técnica e inegavelmente uma forma adequada, tanto do ponto de vista mecânico como microbiológico, de interagir com o espaço endodôntico em busca de uma experiência bem sucedida e previsível. De outra forma, os mais recentes instrumentos endodônticos, muito mais flexíveis em decorrência das novas ligas de baixo módulo de elasticidade empregadas em sua fabricação e dotados de novos índices de conicidade, surgem melhorando tais perspectivas. Desde o surgimento da liga de Níquel-Titânio na Endodontia, na década de oitenta, uma gama imensa de instrumentos desta derivados e para serem empregados com dispositivos mecânicos, eletromecânicos ou pneumocânicos, têm reavivado a esperança de se obter um dispositivo ideal que simulando a cinemática manual supere as limitações operacionais decorrentes, principalmente, da configuração anatômica do canal radicular. Assim, neste experimento verificou-se o desempenho de quatro diferentes recursos técnicos no desgaste da região cervical do canal radicular. Constituíram-se quatro amostras, cada qual composta de 10 espécimes (raízes mésio-vestibulares de primeiros molares superiores), para serem preparadas com (i) Brocas Gates-Glidden, (ii) Brocas Largo-Peeso, (iii) ProFile® .04/.06 & Orifice Shapers e (iv) Pow-R Coronal Shapers. Imagens digitais obtidas antes e após o preparo do canal radicular foram analisadas também digitalmente estudo morfométrico computadorizado avaliando-se a variação das áreas das mesmas em função do desgaste promovido pelos referidos instrumentos. Todos os instrumentos produziram desgaste de ambas as paredes, mesial e distal, do canal radicular na região analisada. A análise estatística das variações de área para o fator parede mesial não mostrou diferenças estatisticamente significantes entre os grupos experimentais para =5%. No entanto quando da comparação dos grupos experimentais para o fator parede distal verificou-se diferenças estatisticamente significantes entre os grupos #1 e #3 para =5%. Ainda, para o fator área total (paredes mesial e distal) verificou-se diferenças estatisticamente signifcantes entre os grupos #3 e #4 para =5%. Concluiu-se que todos os instrumentos testados produzem desgaste tanto da parede mesial como da parede distal do canal radicular e, conseqüentemente, da estrutura dentinária global da região cervical do canal radicular. Por outro lado verificou-se uma tendência da Broca Gates-Glidden em promover maior desgaste da parede distal que o Sistema ProFile® .04/.06 & Orifice Shapers e do Sistema Pow-R Coronal Shapers em promover maior desgaste da estrutura toal que o Sistema ProFile® .04/.06 & Orifice Shapers. / Nowadays is common sense among endodontists that in root canal preparation, mainly the curved ones, the crown-down approach enlarging the cervical third prior instrumentation of the apical third regions provides better interaction between the instrument and the canal walls than the conventional methods. Technically it provides an adequate form to achieve the best and predictable results in cleaning and shaping the root canal system. Additionally the most recent nickel-titanium made endodontic instruments more flexible than the stainless steel instruments and the new taper design have been appeared to improve the endodontic panorama. Since the introduction of the nickel-titanium alloy in Endodontics by Walia et al. in 1988 a number of instruments produced by such alloy in conjunction with the engines new generation have brought new perspectives to deal tridimensionally with the still challenger endodontic space. In this study the performance of four different instruments in the root canal cervical third enlargement was evaluated. Four experimental groups comprised by ten upper molars mesiobuccal roots each were prepared by either (i) Gates bur, (ii) Largo bur, (iii) Profile® .04/.06 & Orifice Shapers or (iv) Pow-R Coronal Shapers. Before and after preparation digitally acquired images were evaluated for area changes within both mesial and distal root canal walls. All instruments produced some amount of wear in both walls and the distals have changed more than the mesials in most times probably due an excentric performance of all evaluated instruments. Comparison of root canal walls wearing among the four experimental groups showed no statistically significant differences (=5%) for mesial wall. However, statistically analyze (=5%) showed significant differences between Experimental Group #1 (Gates-Glidden burs) and Experimental Group #3 (Profile® .04/.06 & Orifice Shapers) for distal walls with the first showing greater wearing than the latter. Also, the results showed statistically significant differences between Experimental Group #4 (Pow-R & Coronal Shapers) and Experimental Group #3 (Profile® & Orifice Shapers) for the entire structure i.e. mesial and distal walls with the first showing the greater than the latter wearing . It was concluded that all tested instruments wear so the mesial as the distal root canal walls. Experimental results have showed that in first upper molaras mesiobuccal roots Gates-Glidden bur for distals and Pow-R nickel-titanium instruments for both walls, i.e. the cervical dentin entire structure, are supposed to wear more root canal cervical third dentin than the others instruments which they were compared.
515

Efeito da temperatura de envelhecimento sobre as propriedades mecânicas e resistência à corrosão por pite do aço inoxidável martensítico endurecido por precipitação UNS S46500. / Effect of aging temperature on mechanical properties and pitting corrosion resistance of age hardnable stainless UNS S46500.

Camila Haga Beraldo 13 December 2013 (has links)
Os aços inoxidáveis endurecidos por precipitação vêm sendo largamente empregados na indústria aeronáutica, por combinar resistência mecânica, tenacidade à fratura e resistência à corrosão. E deste modo, são materiais que possibilitam a substituição dos aços carbonos utilizados atualmente, que necessitam de tratamento superficial adicional, como o cádmio, para melhorar a resistência à corrosão. A utilização desses revestimentos traz desvantagens como o custo, a fabricação, a susceptibilidade à fragilização por hidrogênio além dos aspectos ambientais. Neste contexto, o aço endurecido por precipitação UNS S46500, designado como Custom 465® foi avaliado considerando o efeito da temperatura de envelhecimento sobre as propriedades mecânicas e a resistência à corrosão por pite. Amostras tratadas nas condições solubilizada e envelhecida a 510ºC (H950) e 538ºC (H1000) foram submetidas ao ensaio de tração, caracterização microestrutural e ensaios de polarização potenciodinâmica (PP) para determinar a resistência à corrosão por pite. Os exames microestruturais foram realizados com auxílio de microscopia óptica (MO), microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva (EDS) e difração de raios X. Também foram realizadas análises utilizando o software Thermo-Calc. A resistência à corrosão por pite foi avaliada em solução 0,6M NaCl com adições crescentes de Na2SO4. Os resultados obtidos nos ensaios de PP nas duas condições de tratamento térmico foram comparados entre si e com resultados disponíveis na literatura (CALDERÓN-HERNANDEZ, 2012) para o aço inoxidável UNS S30403 (304L). Os exames e análises da microestrutura revelaram que o aço Custom 465® envelhecido apresenta uma matriz martensítica, precipitados de fase chi, austenita e precipitados Ni3Ti. O tratamento H950 apresentou maior resistência mecânica e menor alongamento do que o tratamento H1000. Tal comportamento foi devido à produção de maior porcentagem de fase chi e menor porcentagem de austenita nesse tratamento de envelhecimento. Os diferentes tratamentos térmicos, condição solubilizada, H950 e H1000 apresentaram praticamente a mesma resistência à corrosão por pite. Por outro lado, o aço Custom 465® apresentou ótima resposta à inibição da nucleação de pite com adições crescentes de sulfato em meio de 0,6M NaCl, sendo que a condição H1000 se sobressai sobre a H950 nessa questão. Além disso, através da adição de sulfato foi 7 possível obter maior resistência a corrosão por pite do aço Custom 465® comparativamente ao aço 304L. Tal comportamento foi discutido em termos da afinidade química entre níquel, cloreto e sulfato, levando a maior resistência à corrosão por pite quando o aço contém maior teor de níquel (que é o caso do aço Custom 465®). Este trabalho indicou que o critério na escolha do tratamento de envelhecimento do aço Custom 465® deve ser o das propriedades mecânicas almejadas, uma vez que a resistência à corrosão por pite mostrou-se praticamente independente do tratamento térmico. / The precipitation hardened stainless steels have been widely used in the aircraft industry to combine mechanical strength, fracture toughness and corrosion resistance. And therefore, are materials that enable replacement of the carbon steels used today, which require additional surface treatment, such as cadmium plating, to improve the corrosion resistance. The use of such coatings brings disadvantages such as cost, manufacturing, susceptibility to hydrogen embrittlement beyond environmental aspects. In this context, the precipitation hardened steel UNS S46500, known as Custom 465® were evaluated for the effect of aging temperature on the mechanical properties and the resistance to pitting corrosion .Treated samples in solubilized and aged condition at 510°C (H950) and 538ºC (H1000) were subjected to tensile strength test, microstructural characterization and potentiodynamic polarization (PP) tests to determine the pitting corrosion resistance. The microstructural studies were performed with the aid of optical microscopy (OM), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and X-ray diffraction. Analyzes were also performed using the Thermo -Calc software. The resistance to pitting corrosion was evaluated at 0.6M NaCl solution with increasing additions of Na2SO4. The results obtained from tests of PP in both heat treatment conditions were compared with each other and with results available in the literature (CALDERÓN HERNANDEZ, 2012) to stainless steel UNS S30403 (304L). The analysis of the microstructure revealed that the steel aged Custom 465 ® presents a martensitic matrix, chi precipitates, Ni3Ti precipitates and austenite phase. The H950 age treatment had higher mechanical strength and lower elongation than the treatment H1000. Such behavior was due to the production of higher percentage of chi and a lower percentage of austenite phase in aging treatment. The different heat treatments, solubilized condition, H950 and H1000 showed almost the same pitting corrosion resistance. On the other hand, the Custom 465® showed good response to pitting inhibition with increasing nucleating additions of sulfate in 0.6M NaCl, with enhanced result for H1000 condition. Furthermore, by adding sulfate was possible to obtain greater pitting corrosion resistance of Custom 465® compared to the 304L steel. This behavior has been discussed in terms of the chemical affinity between nickel, chloride and sulphate, leading to higher pitting corrosion resistance when the steel contains a higher nickel 9 content (which is the case of steel Custom 465®). This study indicates that the criterion in selecting the aging heat treatment of Custom 465® steel must be the desired mechanical properties, since the pitting corrosion resistance was found to be substantially independent of heat treatment.
516

Contribuição aos estudos da validação da curva mestra utilizando os dados (experimentos) do euro-teste. / Contribution to the validation studies of master curve using the data (experiments) from the euro test.

João Lázaro Masini Rossi 29 May 2009 (has links)
Pesquisas sobre a tenacidade à fratura dos aços ferríticos mostram uma grande dispersão dos resultados quando avaliados na região de transição dúctil-fragil. Esta dispersão é fortemente influenciada pela temperatura de ensaio, dimensões e geometria dos corpos-de-prova e também pelo nível de restrições plástica na ponta da trinca. Tais fatores dificultam a previsão, a partir de valores experimentais, de valores de tenacidade à fratura de aços ferríticos para aplicações em casos práticos. Uma forma de contornar essa dificuldade é através do uso das curvas de referencia, descritas no Código ASME. Estas curvas representam envoltórias inferiores de tenacidade à fratura obtida a partir de ensaios envolvendo diversos tipos de aços. Portanto os valores de tenacidade estabelecidos por essas curvas são, em geral, muito conservadores. Então foi proposta pela ASTM uma nova metodologia, chamada curva Mestra, que trata estatisticamente o comportamento à fratura dos aços ferríticos na região de transição e caracteriza um material em particular, através de um parâmetro denominado Temperatura de Referencia (T0). Nesta pesquisa, avaliou-se a influencia da sensibilidade dos parâmetros: Kmin, m e M envolvidos no procedimento do calculo de um parâmetro denominado temperatura de referencia. (T0). A metodologia da curva mestra foi aplicada através dos dados (experimentos) do euro-teste , para as temperaturas: -91 ºC, -60°C, -40°C e 20°C . Em análises de sensibilidade aos parâmetros com os seguintes valores kmin = 0, 10, 30; m= (3), (3,5), (4,5), (5,0) e M = 40, 50, 60. Os resultados apresentados são compatíveis comprovando a eficiência da metodologia para avaliação da tenacidade à fratura dos aços ferríticos na região de transição. Portanto, nestas condições, podemos afirmar que o conceito da curva mestra foi, realmente validado. / The caracterization of the fracture behavior in the ductile-to-brittle transition for ferritic steels is a hard task because fracture toughness is a strong function of temperature in the transition, with the toughness values increasing rapidly over a relatively narrow temperature baud/range and therefore cannot be easily used to evaluate integrity in structural components because of the uncertainty in how to handle these teste results. To overcome this problem in practice, the ASME code has provided reference curves that give estimates of toughness versus temperature. These curves represent lower envelopes to a large set of fracture toughness experimental data for several heats of steel . Therefore, the fracture toughness values obtained from these curves are in general too conservative. In the last decade, a new methodology, formalized in the ASTM standard method E1921-97, has revolutionized the approach used to caracterize transition fracture behavior and has given a rationale for treating the several factors that influence the scatter in the results. Statistical models are used to define a transition curve, called Master Curve, and the transition temperature of a given material is stated by a parameter called reference temperature (T0). In this research, it was evaluated the sensitivity influence of the parameter: Kmin, m and M, involved in the to measurement procedure. The master curve methodology was applied over the data (experiments) of EuroTest for the following temperatures: - 91°C, -60°C, -40°C and -20°C. A parameters sensitivity analysis was made with following values: Kmin=0, 10, 30; m=(3), (3,5), (4,5), (5,0) and M=40, 50, 60. The results are compatible, which confirm the efficiency of the methodology for evaluating the toughness to ferritic steel fracture in the transition region. Therefore, in these conditions, we can state the master curve concept has indeed been validated.
517

Aderência bacteriana: estudo in vitro de superfície de aço inoxidável e liga de titânio-alumínio-vanádio de uso ortopédico / Bacterial adherence: an in vitro study of stainless steel and titanium-aluminium-vanadium alloy surfaces of orthopedic use

Ana Cristina Basso 24 June 2009 (has links)
O uso de metais na fabricação de implantes ortopédicos iniciou-se nas primeiras décadas do século XX. O aumento do uso de biomateriais implantáveis aumentam também os casos de infecção. A colonização da superfície do biomaterial pode ter início no momento da inserção do corpo estranho no organismo e geralmente é causada por microrganismos da microbiota da pele ou região adjacente ao implante. Este estudo teve por objetivo avaliar por métodos microbiológicos e microscópio eletrônico de varredura (MEV), a aderência bacteriana à superfície de aço inoxidável e liga de titânio de uso médico, bem como a molhabilidade da superfície destes metais. As bactérias usadas foram Staphylococcus epidermidis ATCC 12228 e Staphylococcus aureus ATCC 25923. Os discos de aço inoxidável (15,0 mm de diâmetro x 2,0 mm de espessura) e de liga de titânio (12,0 mm de diâmetro x 2,0 mm de espessura) foram inseridos, asséptica e separadamente, em tubos contendo 15,0 mL de caldo Mueller Hinton e 200,0 \'mü\'L de suspensão bacteriana da ordem de \'10 POT.8\' UFC/mL. Cada bactéria foi estudada individualmente. Os tubos foram incubados por 1, 6, 24, 48 e 72 horas sob agitação a 37 graus Celsius. Após os períodos de incubação, os discos foram retirados do caldo de cultura e submetidos ao banho de ultrassom em 5,0 mL de solução fisiológica 0,85% esterilizada. Deste líquido, foram realizadas diluições da ordem de \'10 POT.-1\' a \'10 POT.-4\' para a quantificação de células viáveis. Os valores foram expressos em UFC/mL. Para S. epidermidis sobre a liga de titânio, o número de células viáveis foi em 1 hora: 7,20 x \'10 POT.4\'; 6 horas: 3,90 x \'10 POT.6\'; 24 horas: 3,80 x \'10 POT.6\'; 48 horas: 9,70 x \'10 POT.6\' e 72 horas: 1,00 x \'10 POT.7\'. Sobre o aço inoxidável, o número de células viáveis foi em 1 hora: 3,00 x \'10 POT.3\'; 6 horas: 2,90 x \'10 POT.6\'; 24 horas: 3,20 x \'10 POT.6\'; 48 horas: 1,41 x \'10 POT.7\' e 72 horas: 1,88 x \'10 POT.7\'. Para S. aureus ) sobre a liga de titânio, o número de células viáveis foi em 1 hora: 2,00 x \'10 POT.3\'; 6 horas: 1,00 x \'10 POT.4\'; 24 horas: 3,10 x \'10 POT.4\'; 48 horas: 4,30 x \'10 POT.4\' e 72 horas: 5,80 x \'10 POT.3\'. Sobre o aço inoxidável, o número de células viáveis foi em 1 hora: 6,00 x \'10 POT.3\'; 6 horas: 2,00 x \'10 POT.3\'; 24 horas: 1,50 x \'10 POT.4\'; 48 horas: 3,20 x \'10 POT.5\' e 72 horas: 6,00 x \'10 POT.3\'. Ambas as superfícies metálicas foram caracterizadas como de média molhabilidade, onde a liga de titânio teve média \'+ OU -\' desvio padrão de 39,016 \'+ OU -\' 11,267 e o aço inoxidável 58,083 \'+ OU -\' 7,165. Tanto o S. aureus quanto o S. epidermidis aderiram às superfícies dos biomateriais estudados, como foi observado por meio de MEV. Com base nos resultados é possível concluir que os dois microrganismos são capazes de aderir a superfícies metálicas. Isto aumenta a preocupação quanto à patogênese das infecções relacionadas a implantes ortopédicos, uma vez que esses microrganismos estão presentes na pele humana e oferecem o risco de reações inflamatórias e infecção, promovendo a perda do implante para efetivar a cura. / The utilization of metals in the manufacture of orthopedic implants started in first decades of twentieth century. The increased use of implantable biomaterials increased also infection cases. Biomaterial surface colonization can start at the moment of foreign body insertion in the organism and is usually caused by microorganisms of skin microbiota or adjacent region to the implant. This study aimed to evaluate microbiological methods and scanning electron microscopy (SEM), the bacterial adhesion to surface of stainless steel and titanium alloy of medical use, as well as the surface wetability of these metals. The used bacteria were Staphylococcus epidermidis ATCC 12228 and Staphylococcus aureus ATCC 25923. The stainless steel (15,0 mm diameter x 2,0 mm thick) and titanium alloy (12,0 mm diameter x 2,0 mm thick) discs were inserted, aseptic and individually, into tubes containing 15,0 mL Mueller Hinton broth and 200,0 \'mü\'L of bacterial suspension with \'10 POT.8\' CFU/mL concentration. Each bacterium was individually studied. The tubes were incubated for 1, 6, 24, 48 and 72 hours under agitation at 37 Celsius degrees. After incubation periods, the discs were removed from culture broth and submitted to the ultrasound bath in 5,0 mL of sterile saline. From this liquid were realized dilutions of \'10 POT.-1\' to \'10 POT.-4\' to quantify the viable cells. Values were expressed in CFU/mL. S. epidermidis over titanium alloy viable cells number was in 1 hour: 7,20 x \'10POT.4\'; 6 hours: 3,90 x \'10 POT.6\'; 24 hours: 3,80 x \'10 POT.6\'; 48 hours: 9,70 x \'10 POT.6\' and 72 hours: 1,00 x \'10 POT.7\'. Over stainless steel viable cells number was in 1 hour: 3,00 x \'10 POT.3\'; 6 hours: 2,90 x \'10 POT.6\'; 24 hours: 3,20 x \'10 POT.6\'; 48 hours: 1,41 x \'10 POT.7\' and 72 hours: 1,88 x \'10 POT.7\'. To S. aureus over titanium alloy viable cells number was in 1 hour: 2,00 x \'10 POT.3\'; 6 hours: 1,00 x \'10 POT.4\'; 24 hours: 3,10 x \'10 POT.4\'; 48 hours: 4,30 x \'10 POT.4\' and 72 hours: 5,80 x \'10 POT.3\' and over stainless steel viable cells number was in 1 hour: 6,00 x \'10 POT.3\'; 6 hours: 2,00 x \'10 POT.3\'; 24 hours: 1,50 x \'10 POT.4\'; 48 hours: 3,20 x \'10 POT.5\' and 72 hours: 6,00 x \'10 POT.3\'. Both metal surfaces were characterized as medium wetability, where the contact angle of titanium alloy was mean \'+ OU -\' standard deviation 39,016 \'+ OU -\' 11,267 and stainless steel 58,083 \'+ OU -\' 7,165. Both S. aureus as S. epidermidis adhered to surfaces of biomaterials studied, as observed by SEM. Based on the results we concluded that two microorganisms are able to adhere to metal surfaces. This increases the concern about the pathogenesis of infections related to orthopedic implants, since these microorganisms are present in human skin and provide the risk of infection and inflammatory reactions, furthering implant loss to effective cure.
518

Estudo do processo de estampagem para materiais alternativos na fabricação de um componente para a indústria de máquinas agrícolas

Bau, Atilano Roberto January 2015 (has links)
No presente trabalho, a conformabilidade do aço inoxinoxidável AISI 201 foi comparada com o aço inoxidável AISI 304. O aço inoxidável AISI 201 é uma liga baixo níquel ligado com manganês e nitrogênio. Nesse estudo a conformabilidade dos dois materiais foi examinada por meio de ensaios tecnológicos como ensaio de tração, determinação da curva de escoamento, determinação do índice de anisotropia, ensaio Erichsen, dureza, composição química, simulação computacional do processo de estampagem e estampagem dos blanks. O aço inoxidável AISI 201 possui propriedades como limite de escoamento e tensão de ruptura superior as do inoxidável AISI 304. Os dois aços possuem uma similaridade na anisotropia. A máxima altura alcançada no momento da fratura pelo ensaio Erichsen também é semelhante para os dois materiais. O aço inox AISI 201 apresenta uma dureza maior que o inoxidável AISI 304. Na composição química os dois aços apresentam elementos fora do especificado, caracterizando um problema de qualidade na fabricação desses aços. A simulação computacional do processo de estampagem apresentou uma redução de espessura na região mais critica, sem comprometer a estampagem do componente. Uma vez estampadas, obteve-se peças sem indícios de trincas, conforme previsto pela simulação computacional. Os resultados desse trabalho sugerem a possibilidade de utilização do aço inoxidável AISI 201 como opção para substituição ao inoxidável AISI 304, tendo uma observação a ser feita quanto aos cuidados na qualidade durante a fabricação do aço para que atenda os padrões exigidos. / In this study, the formability of stainless steel AISI 201 was compared to stainless steel AISI 304 stainless steel AISI 201 is a low alloy nickel alloyed with manganese and nitrogen. In this study, the formability of the two materials was examined by means of technological tests such as tensile test, determination of the flow curve, determining the anisotropy index, Erichsen test, hardness, chemical composition, computer simulation of the stamping process and stamping of the blanks. Stainless steel AISI 201 has properties such as yield strength and higher breakdown voltage of the stainless steel AISI 304. The two steels have a similarity in anisotropy. The maximum height reached at the time of fracture by Erichsen test is also similar for the two materials. Stainless steel AISI 201 has a hardness greater than the stainless steel AISI 304. In chemistry the two steels have elements outside the specified, featuring a quality problem in manufacturing these steels. A computer simulation of the printing process showed a reduction in thickness in the most critical region, without compromising the component stamping. Once stamped, gave no broken pieces of evidence as provided by the computer simulation. The findings suggest the possibility of use of stainless steel AISI 201 as an option to replace the stainless steel AISI 304, with a point to be made about the care as during the manufacture of steel that meets the required standards.
519

Avaliação da resistência à corrosão de uma junta de aço inoxidável dúplex UNS S31803 soldada por processo a fricção com pino consumível

Ribeiro, Ricardo Feyh January 2014 (has links)
A corrosão acarreta riscos ambientais, perdas de vidas e elevados gastos financeiros. Logo, a prevenção e o controle tornam-se mandatórios para a operação segura e rentável de estruturas metálicas. O combate à corrosão depende essencialmente de uma maior compreensão dos fenômenos envolvidos e de investimentos em novas tecnologias. A indústria do petróleo recorre frequentemente à aplicação do aço inoxidável UNS S31803 em suas estruturas, devido a sua boa resistência mecânica e à corrosão. Apesar de ser considerada uma liga de boa soldabilidade, ainda é possível que existam heterogeneidades, defeitos e a formação de fases indesejadas após a soldagem, os quais podem deteriorar a resistência à corrosão da junta. A técnica de soldagem com pino consumível (FHPP) mostra-se como uma recente alternativa para o setor industrial offshore devido as suas qualidades inerentes. Deste modo, a finalidade desse trabalho é avaliar separadamente a resistência à corrosão das principais regiões da junta soldada por FHPP (material base do pino e do substrato e a zona termomecanicamente afetada) de aço inoxidável dúplex UNS S31803, frente a um meio de água do mar sintética na condição naturalmente aerada. De tal modo, é possível identificar eventual comprometimento da resistência à corrosão de uniões desta natureza. Para isso foi desenvolvida uma célula eletroquímica de três eletrodos com dimensões reduzidas (microcélula). Assim, as regiões principais da junta soldada foram analisadas separadamente através de polarizações potenciodinâmicas cíclicas. Foi possível obter os potenciais de corrosão (Ecor), de quebra de passividade (Eq) e de proteção (Eprot1 e Eprot2), junto com os coeficientes de Tafel (ba e bc) e as densidades de corrente de corrosão (icor) e de quebra de passividade (iq). Com base nestas observações, acredita-se que a junta soldada apresenta comportamento eletroquímico em todas suas regiões. / Corrosion impacts annually in environmental risks, loss of human life and high financial costs. Thus, the prevention and the control became mandatory for safe and profitable operation of metal structures. Therefore, the maintenance of acceptable levels of corrosion depends essentially on a greater understanding of the corrosion phenomena and investments in new technologies. The petroleum industry often relies on the UNS S31803 stainless steel in their structures, due to the good mechanical and corrosion resistance of this material. Even though it is considered to be an alloy of good weldability, it is still possible to have heterogeneities, defects and formation of deleterious phases after the welding, which may result in the weakening of the corrosion resistance of the joint. Friction hydro pillar process, arise as a good and recent alternative to the offshore industry, due to its inherent qualities. Therefore, the aim of this study is to individually evaluate the corrosion resistance of the main regions (base materials from the pin and from the subtract and the thermo-mechanically affected zone) of the duplex stainless steel UNS S31803 joint welded by FHPP, against synthetic seawater in the naturally aerated condition, in order to identify potential impairment of the corrosion resistance of these joints. For this, it was developed a three electrode electrochemical cell with reduced dimensions (microcell). This way, the main regions of the welded joint could be analyzed separately with cyclic potenciodinâmica polarizations. It was obtained the corrosion (Ecor), pitting (Eq) and protective (Eprot1 and Eprot2) potentials, along with the Tafel slopes (ba and bc) and corrosion (icor) and passivity breakdown (iq) current densities. Based on these observations, it is believed that the welded joint present good electrochemical behavior in all its regions.
520

Avaliação de misturas injetáveis aplicadas à fabricação de micro componente para pinças de biópsias por moldagem de pós por injeção

Tavares, André Carvalho January 2014 (has links)
A moldagem de pós por injeção (MPI) foi empregada neste trabalho para a fabricação de micro componentes de uma pinça de biópsia, através do desenvolvimento de misturas injetáveis. Utilizou-se a liga de aço inoxidável AISI 316L, liga reconhecidamente biocompatível, para obtenção dos micro componentes. Determinando a quantidade de 39% em volume para fração orgânica das quatro formulações de misturas injetáveis produzidas neste trabalho. Os polímeros estruturais empregados foram o PP, o PEBDL, o PEAD e o PMMA. Como material auxiliar de fluxo foi utilizada a parafina e para agente surfactante, o ácido esteárico. O desenvolvimento do sistema de extração química do polímero auxiliar de fluxo com solvente e posterior extração térmica do ligante em forno convencional e em um reator a plasma foram testados, ainda se empregou estes para testes em sinterização a temperaturas 1200°C, 1250°C e 1300°C. A extração química foi realizada com hexano atingindo 2,41% em massa de material extraído das amostras, após seis horas em um sistema aquecido entre 60°C e 70°C e uma atmosfera de vácuo. As amostras foram testadas química, física, mecânica e eletroquimicamente. Obteve-se os melhores resultados em termos de densificação de 7,05 g/cm³ para as amostras extraídas a plasma e sinterizadas a 1300 °C à vácuo em forno tubular. Isso significa uma densificação de 88,96% comparada a densidade do material comercial cuja a densidade é 7,93 g/cm³. As microdurezas encontradas nas amostras sinterizadas a 1300 °C em um forno convencional obtiveram valores de 208HV se mostrando maiores do que os 165HV obtido de um material maciço fabricado pelo extrusão e comercialmente vendido. Encontrou-se a dureza de 55HRB nas amostras processadas a 1300 °C, devido a presença de poros em componentes sinterizados. Nos componentes maciços foram medidos a dureza de 88HRB que foi maior que os resultados das amostras sinterizadas. As análises metalográficas mostraram um tamanho de grão variando entre, 30 e 50μm, se comparado ao tamanho de partícula médio do D90 de foi de 8,59 μm, se estima que este aumento foi entorno de três vezes e meia. Os testes químicos revelaram que a extração térmica em reatores a plasma melhoram significativamente os níveis de C, N, H e S quando comparados ao processo de extração térmica em forno convencional. A redução dos níveis de carbono residual, resultaram em diminuição do carboneto de cromo nas amostras, provocando uma menor corrosão. As amostras sinterizadas a 1200 °C a plasma apresentaram os melhores resultados de corrosão. / The powders injection molding (PIM) was used in this research, with objective to manufacture micro component, for application in biopsy forceps being developed injectable mixtures . It was used the powder stainless steel AISI 316L alloy, material biocompatible, to obtain the micro components. Through tests was determining the amount optimal volume in 39 % for the organic fraction of the four formulations of injectable mixtures produced in this research. The structural polymers used were PP , LLDPE , HDPE and PMMA . The paraffin was used as auxiliary material flow, the surfactant agent employed that was stearic acid . The development of chemical debiding and the thermal extraction for binder system, was used the conventional furnace and in a plasma reactor were tested also be employed for these tests sintering temperature 1200 ° C , 1250 °C and 1300 °C. Chemical extraction was performed with hexane achieving 2.41 % by extracted mass of sample material, after six hours in a heated system between 60 °C and 70 °C and a vacuum atmosphere. The samples were tested analysis by chemical , physical , mechanical and electrochemical.If it obtained the best results in terms of densification of 7.05g/cm ³ for plasma samples extracted and sintering at 1300 °C in vacuum tube furnace . This means densification of 88.96 % compared to the density of commercial material whose density is 7.93 g/cm ³ . The microhardness found in the samples sintered at 1300°C in a conventional furnace obtained 208HV microhardness showing larger than the commercial 165HV. Found that the HRB hardness of 55 in the samples processed at 1300 °C, due to the presence of pores in sintered parts. In the extruded components were measured hardness of 88HRB which was higher than the results of the sintered samples. The metallographic analysis showing a grain size ranging between 30 and 50μm , compared to the average particle size D90 was 8,59 microns is estimated that this increase was around three and half times . The chemical tests revealed that the thermal plasma extraction reactor significantly improve the levels of C, N , H and S compared to the process heat extraction in a conventional furnace . The residual carbon levels significantly improved, which helps to avoid the formation of chromium carbides , which aumnetou corrosion resistance . The best results in terms of corrosion were found for the samples sintered at 1200 ° C the plasma.

Page generated in 0.0547 seconds