• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 940
  • 82
  • 48
  • 14
  • 13
  • 13
  • 12
  • 11
  • 8
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 1102
  • 541
  • 129
  • 124
  • 117
  • 85
  • 77
  • 68
  • 63
  • 55
  • 52
  • 49
  • 45
  • 43
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Processos de síntese de pós cerâmicos a base de diopsita dopada com disprósio para materiais luminescentes emissores de luz branca / Synthesis processes of ceramic powders based on Dy-doped diopside for the white-emitting luminescent materials

Morais, Vinicius Ribas de 06 February 2019 (has links)
Fósforos à base de diopsita (CaMgSi2O6) dopada com disprósio (Dy3+) foram preparados a partir da combinação dos métodos sol-gel e coprecipitação. Foram adotados três procedimentos diferentes para síntese, nos quais gel de sílica foi obtido a partir de solução de Na2SiO3 e a ele foi adicionado precipitados de hidróxidos de cálcio, magnésio e disprósio. A etapa de lavagem da mistura dos precipitados foi estudada para evitar dissolução dos hidróxidos de cálcio e magnésio. O produto lavado, após calcinação a 900°C por períodos de 1 a 3 horas, foi obtido o pó cerâmico apresentando diopsita como fase principal, confirmada por análise de DRX. O espectro de emissão de fotoluminescência do pó cerâmico apresentou os picos característicos do Dy3+, localizados nas regiões do azul e do amarelo. A partir da relação entre as intensidades desses picos, é possível obter luz branca. Foram variadas as concentrações de dopagem de disprósio nas amostras. Aquelas com concentrações de até 0,5%mol em disprósio foram as que apresentaram emissões mais próximas do branco, segundo o diagrama CIE. Foi observado um comportamento interessante da relação entre a luminescência em função do teor de dopagem de disprósio. Verificou-se que o aumento do teor de disprósio acarreta diminuição da intensidade de emissão até certo ponto onde ela volta a aumentar. As curvas de persistência luminescente apresentaram decaimento da ordem de décimos de segundos, o que pode indicar que o material não apresenta defeitos em quantidade ou profundidade suficiente para aplicações como fósforo persistente. / Dy-doped diopside (CaMgSi2O6) based phosphors were prepared by combining sol-gel and coprecipitation methods, using three different routes. Silica gel was obtained from aqueous Na2SiO3 solution, and then hydroxide precipitates of calcium, magnesium and dysprosium were added to the gel. The washing process of the mixture of precipitates step was studied to avoid dissolution of calcium and magnesium hydroxides. The washed product, after calcining at 900° C for periods of 1 to 3 hours, a ceramic powder showing diopside as main crystalline phase was reached, confirmed by XRD analysis. The emission spectrum of photoluminescence of ceramic powder presented the characteristic peaks of Dy3+, located in the regions of blue and yellow. From the relationship between the intensities of these peaks, white light can be obtained. The concentration of dysprosium was varied in the samples. Those with concentrations of up to 0.5% in dysprosium were those which presented the white emissions, according to the CIE diagram. Interesting behavior was observed relation between luminescence and of dysprosium doping content in the samples. It was found that by increasing the content of dysprosium, the emission intensity decreased to a point where it back to increasing. Persistence luminescent curves presented very fast decay, of tenths of seconds, which may indicate that the material does not present defects in quantity or enough depth for applications such as persistent phosphors.
112

Nuevos modelos para la caracterización de aerosoles en espectrometría atómica: aplicaciones de la dispersión de la luz láser

Alvarez, Mariela L. 20 February 2001 (has links)
No description available.
113

HISTOMORFOMETRIA DE LESÃO CUTÂNEA INDUZIDA SUBMETIDA A DIFERENTES TRATAMENTOS

Gabriela Chaves Mendes Justino 09 November 2010 (has links)
O reparo tecidual é um estado dinâmico que compreende diferentes processos, entre eles, inflamação, proliferação e remodelação, sendo que cada fase apresenta células e funções específicas. O LED é uma fonte de luz que tem sido utilizada na modalidade fototerapêutica no processo de cicatrização de feridas. A própolis também apresenta características em sua composição que favorece o reparo cicatricial. O presente estudo utilizou como terapias o LED, a própolis e seus usos associados, com o objetivo de compreender a ação desses diferentes tratamentos na resposta inflamatória induzida considerando a cinética do infiltrado inflamatório. O modelo experimental consistia na indução de ferida cirúrgica no dorso de 40 camundongos. Os animais foram divididos em 4 grupos: Controle, LED, Própolis e LED e Própolis, todos apresentaram subgrupos com animais sacrificados aos sete dias e quatorze dias após indução da lesão. A avaliação da histomorfometria foi realizada através de imagens capturadas e avaliadas por sistema de captura de imagens. Os achados da análise nos permitiram concluir que o LED isoladamente tem atividade biomoduladora positiva sobre o número de fibrócitos/fibroblastos e na neovascularização, no entanto, age como antiinflamatório sobre o infiltrado de células do sistema imune. O tratamento isolado com própolis age como proinflamatorio e não apresenta efeito estimulador na proliferação de fibrócitos/fibroblastos, determinando, porém aumento de colágeno e neovascularização enquanto inibe o aumento de SFA. O uso concomitante da própolis e LED atuou como agente antiinflamatório, além de exacerbar a ação do LED na produção de colágeno e na neovascularização.
114

ESTUDO COMPARATIVO DAS RESPOSTAS TERAPÊUTICAS DO LASER DIODO VISÍVEL E DO LED NO TRATAMENTO DO FOTOENVELHECIMENTO INDUZIDO EM CAMUNDONGOS

Juliana Bittencourt e Xavier 10 November 2010 (has links)
O bronzeamento, por ser interpretado por muitos como sinônimo de beleza e saúde, tem contribuído para exacerbar os efeitos cumulativos do sol tanto na epiderme quanto na derme. Sendo assim, tem-se aumentado a busca por tratamentos eficazes à fim de reduzir os sinais do envelhecimento extrínseco. Baseando-se neste fato, o presente trabalho apresentou como objetivo comparar duas modalidades terapêuticas, sendo elas o LED e o LASER para o tratamento do fotoenvelhecimento induzido em camundongos BALB-c. Para a realização do experimento foram utilizados, inicialmente, 40 animais sendo estes divididos em quatro grupos: grupo controle (irradiado com lâmpada isenta de RUV), grupo UV (submetido à exposição à RUV e sem tratamento), grupo UV+LED (submetido à exposição à RUV e tratados com LED) e grupo UV+LASER (submetido à exposição à RUV e tratados com LASER). A avaliação da histomorfometria foi realizada através de imagens capturadas e avaliadas por sistema de captura de imagens. Através dos resultados da análise concluiu-se que o protocolo adotado foi capaz de induzir o processo de fotoenvelhecimento sendo possível evidenciar hiperceratose, hipergranulose, acantose e espongiose na camada epidérmica. Na derme observou-se redução no número de fibras colágenas, aumento na quantidade de substância fundamental amorfa (SFA), do infiltrado inflamatório e no número de fibrócitos/fibroblastos. O LED demonstrou melhores resultados no tratamento da pele fotoenvelhecida visto que apresentou efeitos satisfatórios tanto na derme quanto na epiderme. Já o LASER foi capaz de agir de forma significativa apenas na derme.
115

Efeito da laserterapia de baixa potência na paracoccidioidomicose experimental murina: caracterização do exsudato celular e do perfil de citocinas

MENDES, Ana Carolina Silvério Cerqueira 28 April 2017 (has links)
A imunidade inata mostra-se importante na defesa do hospedeiro contra a infecção por fungos, e dentro desse contexto macrófagos e neutrófilos (PMN) desempenham papel central na paracoccidioidomicose. O tratamento desta doença inclui o uso de antifúngicos que, além do prolongado tempo de administração, podem ter diversos efeitos colaterais. A laserterapia de baixa potência (LLLT- low level laser therapy) vem sendo utlizada como tratamento adjuvante para muitas enfermidades, e já foi demonstrado seu efeito ativador em neutrófilos, se fazendo necessário compreender melhor os mecanismos imunológicos envolvidos nesse processo. Neste trabalho avaliamos os efeitos da LLLT aplicada in vivo nas patas traseiras de camundongos, infectados pela via ―air pouch‖ subcutânea com a cepa virulenta do P. brasiliensis Pb18 ou a cepa de baixa virulência Pb265, visando atingir células em formação na medula. Grupos de animais não irradiados foram utilizados como controle. Após 8 dias de infecção as células da ―air pouch‖ foram coletadas e analisadas quanto ao número, concentração proteica, liberação de espécies reativas de oxigênio (ERO), atividade mitocondrial de PMN e perfil de migração e secreção das citocinas (GM-CSF, IFN- γ, IL-12, IL-4, IL-10 e IL-17) pelo exsudato celular. O tratamento de animais com LLLT aumentou a atividade mitocondrial, o conteúdo de proteínas e a liberação de ERO por parte dos PMN e diminuiu a secreção da IL-10 pelas células do exsudato na infecção com a cepa virulenta Pb18. Por sua vez, a infecção com a cepa de baixa virulência Pb265 também levou a um aumento na atividade mitocondrial, mas houve diminuição no conteúdo de proteínas e a liberação de ERO foi semelhante ao controle não irradiado. Não foi observada diferença na secreção das citocinas GM-CSF, IFN-γ, IL-12, IL-4 e IL-17 pelas células do exsudato estimuladas por ambas às cepas. Quanto à migração celular, os PMN constituem o principal tipo celular encontrado no local do inóculo, seguido pelos linfócitos e monócitos. O número de PMN foi diminuído no tratamento com LLLT quando o estímulo foi o Pb18 e aumentado quando foi o Pb265. Para os linfócitos ocorreu o inverso, no grupo estimulado com Pb18 o laser atuou aumentando esse tipo celular, e diminuindo quando o estímulo foi o Pb265. Já para os monócitos não houve alteração quando o estimulo foi o Pb18 e houve uma diminuição quando o estímulo foi o Pb265 no grupo tratado com LLLT. Os resultados sugerem que o tratamento com LLLT confere um potencial fungicida aos neutrófilos e uma maior resolução da infecção causada pela cepa virulenta Pb18. / Innate immunity is an important component of host defense against fungi, and in this context machophages and neutrophils (PMN) play a central role in paracoccidioidomycosis. The treatment of this disease includes the use of antifungals, which in addition to the prolonged administration time needed may cause many side effects. Low level laser therapy (LLLT) has been used as an adjuvant treatment for many ailments and its modulating effect on neutrophils has already been demonstrated; however it is necessary to better understand the mechanisms involved in this process. In this work, we evaluated the effects of LLLT applied ―in vivo‖ at the hind paws in mice, aiming the bone marrow. These mice were infected in the subcutaneous air pouch with Pb18 or Pb265 P. brasiliensis isolates. Unirradiated animals were used as controls. After 8 days of infection the cells of air pouch were collected and analyzed for the number, protein concentration and release of ROS, mitochondrial activity of PMN and migration profile and secretion of cytokines (GM-CSF, IFN-γ, IL-12, IL- 4, IL-10 and IL-17) by the cells present in the exudate. LLLT-treated animals showed increased mitochondrial activity, protein content and release of ROS by PMN and in the number of cells and decreased the secretion of IL-10 exudate cells obtained after inoculation with the virulent strain Pb18. In turn, the infection with the low virulence strain Pb265 also led to an increase in mitochondrial activity, but there was a decrease in protein concentration and the release of ROS was similar to that of the unirradiated controls.. No differences were observed in the secretion of the GM-CSF, IFN-γ, IL-12, IL-4 and IL-17 cytokines by exudate cells stimulated by any of the strains. Regarding cell migration, PMN are the main cell type found at the inoculum site, followed by lymphocytes and monocytes. The number of PMN was decreased in the treatment with LLLT when the stimulus was Pb18 and increased when it was Pb265. For the lymphocytes the reverse occurred, in the group stimulated with Pb18 the laser acted increasing this cellular type, and decreasing when the stimulus was the Pb265. For monocytes, there was no change when the stimulus was Pb18 and there was a decrease when the stimulus was Pb265 in the group treated with LLLT. The results suggest that treatment with LLLT elicits a fungicidal activity to the PMN and higher resolution of the infection caused by the virulent Pb18 strain. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
116

Estado ligado de dois bósons em (2+1) dimensões no espaço de Minkowski e a representação integral de Nakanishi na frente de luz

Anderson Madruga dos Santos 13 May 2013 (has links)
Estendemos a representação integral de Nakanishi para resolver o problema do estado ligado relativístico de duas partículas em duas dimensões espaciais no espaço de Minkowski, como um protótipo de um exciton (par eletrón-buraco) em uma folha de grafeno. Utilizamos neste estudo a equação de Bethe-Salpeter em 2+1 dimensões na aproximação de escada, para dois bósons interagentes através da troca de um bóson massivo (modelo de Yukawa). A amplitude de Bethe-Salpeter do estado ligado, solução da equação homogênea, foi escrita na representação integral de Nakanishi em 2+1 dimensões, e a equação para a função peso foi deduzida. O método utilizado para essa derivação faz uso da projeção na frente de luz da equação de Bethe-Salpeter, como recentemente feito para 3+1 dimensões. O essencial nesse método é reconhecer que a dinâmica efetiva da componente de valência da função de onda na frente de luz é capaz de descrever a complexidade da equação de Bethe-Salpeter quando essa é projetada na frente de luz. Também derivamos uma forma simplificada da equação integral para a função peso de Nakanishi baseados na conjectura de unicidade dessa função no regime não-pertubativo. Apresentamos, também, uma análise numérica da solução da eq. de Bethe-Salpeter para o estado ligado dos dois bósons em 2+1 dimensões na aproximação de escada.
117

Equação de bethe-salpeter em 2+1 dimensões para estado ligado de dois bósons no espaço de minkowski

Vitor Fernando Gigante de Paiva 04 December 2014 (has links)
A representação integral perturbativa de Nakanishi é usada pela primeira vez para resolver numericamente o problema relativístico do estado ligado de dois bósons em 2+1 dimensões no espaço de Minkowski. Utilizamos a representação integral perturbativa de Nakanishi para a amplitude de Bethe-Salpeter em três (2+1) dimensões, com o objetivo de obter o espetro e a estrutura de estados ligados, soluções da equação de Bethe-Salpeter homogênea, no espaço de Minkowski. A projeção na frente de luz da equação homogênea tri-dimensional de Bethe-Salpeter é usada na derivação da equação para a função peso de Nakanishi de estados ligados. Apresentamos o desenvolvimento formal em detalhes e aplicamos no estudo de um sistema ligado, composto por dois bósons escalares massivos interagindo através da troca de um campo escalar massivo. A forma explicita da equação integral homogênea é obtida na aproximação escada para a função peso de Nakanishi em 2+1 dimensões, e como uma simples aplicação do nosso formalismo, o modelo de Wick-Cutkosky é discutido. Realizamos um estudo quantitativo das soluções para os estados ligados da equação de Bethe-Salpeter em 2+1 dimensões, resolvendo numericamente a equação integral para a função peso de Nakanishi. Validamos o método quantitativamente comparando nossos resultados da equação de Bethe-Salpeter no Euclidiano.
118

Avaliação clínica da sensibilidade e efetividade do clareamento em consultório de dentes polpados, com e sem o emprego de fonte de luz: controle de 12 meses / Clinical evaluation of sensitivity and effectiveness of in-office whitening in sounds teeth, with and without the use of light source: 12 months follow-up

Rosa, Enio Ratton 14 May 2012 (has links)
Este estudo in vivo analisou comparativamente duas técnicas de clareamento de dentes polpados, quanto ao grau de sensibilidade, mudança de cor e estabilidade do tratamento num período de doze meses. Dez pacientes foram selecionados de acordo com os critérios de inclusão e exclusão, e submetidos ao clareamento em consultório, sendo que o mesmo paciente recebeu os dois protocolos de clareamento. Grupo A (GA): três aplicações de 15 (totalizando 45) do gel de peróxido de hidrogênio (PH) 35% (Lase Peroxide Sensy, DMC Equipamentos Ltda.), nos hemi-arcos inferior e superior esquerdo. Grupo B (GB): três aplicações do gel PH 35% ativado com luz híbrida de LED/laser de diodo (Whitening Lase II DMC Equipamentos Ltda.) por 2, com intervalo de 30 (730), totalizando 2230, nos hemi-arcos inferior e superior direito. A avaliação da cor foi realizada com o espectrofotômetro Vita EasyShade (VITA), sendo a diferença mensurada através do sistema CIE-Lab antes do clareamento, após 24 horas, 1 semana, 6 e 12 meses. A sensibilidade dentária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, após 24 horas e 1 semana. Para as variáveis luminosidade (?L) e alteração de cor (?E), ANOVA a dois critérios (período e luz) revelou haver diferenças estatisticamente significantes intra e intergrupos em função dos períodos avaliados (p<0,001). O teste de Tukey (p<0,001) para comparações individuais apontou diferenças significantes intergrupos para os dentes superiores nos períodos de 1 mês, 6 meses e 1 ano com os demais tempos avaliados. Para os dentes inferiores não houve diferenças estatísticas intra e intergrupos (p=0.0821). O GB ativado com luz apresentou, imediatamente após o clareamento, o menor grau de sensibilidade dentária com diferença estatística (p=0,043) em comparação ao GA (sem luz). Os dois protocolos de clareamento com e sem luz avaliados durante 12 meses foram semelhantes quanto a efetividade do clareamento dental. Por outro lado, a utilização da fonte de luz híbrida diminuiu o tempo de tratamento em 50% e proporcionou menor grau de sensibilidade pós-operatória. / This study examined in vivo comparison of two techniques for whitening pulp teeth, the degree of sensitivity, color change and stability of treatment over a period of twelve months. Ten patients were selected according to the criteria for inclusion and exclusion, and subjected to in-office bleaching, and the same patient received both protocols whitening. Group A (GA): three applications of 15\' (total 45\') of hydrogen peroxide gel (PH) 35% (Sensy Lase Peroxide, DMC Equipment Ltd.), Hemi-arches in the lower and upper left. Group B (GB): three applications of the gel 35% PH with light activated hybrid LED / laser diode (Whitening Lase II DMC Equipments Ltda.) By 2 \', with an interval of 30\' (7\'30\"), totaling 22\'30\", hemi-arches in the lower and upper right. The evaluation was performed color with the spectrophotometer Vita Easyshade (VITA), and the difference measured with the CIE-Lab system before the treatment, after 24 hours, 1 week, 6 and 12 months. The tooth sensitivity was assessed using the VAS questionnaire before and immediately after bleaching, after 24 hours and 1 week. For the variable brightness (?L) and color change (?E), two-way ANOVA (time and light) revealed statistically significant differences within and between groups on the basis of the evaluation period (p<0.001). The Tukey test (p<0.001) for individual comparisons showed significant differences between groups for the upper teeth at 1 month, 6 months and 1 year with the other times evaluated. For the lower teeth no statistical differences within and between groups (p=0.0821). The GB had activated with light, immediately after bleaching, the lowest degree of tooth sensitivity with statistical difference (p=0.043) compared to GA (no light). The two protocols with and without light bleaching evaluated during 12 months were similar in effectiveness of tooth whitening. Moreover, the use of the light source hybrid decreases the time of treatment provided by 50% and less sensitivity postoperative.
119

Diseño e implementación de equipo regenerador de tejidos blandos basado en diodos emisores de luz y láser diodo

Romero Román, Herbert Ludwig, Manrique Solorzano, Susan Leslie 08 February 2013 (has links)
El objetivo del presente estudio es diseñar e implementar un equipo regenerador de tejidos blandos basado en diodos emisores de luz y diodo láser, con potencia luminosa regulable entre 5-100mW, en pasos de 5mW; con frecuencia de pulsación del haz de luz, generado por una onda cuadrada simétrica, variable entre 1-100Hz, en pasos de 1Hz; y tiempo de aplicación entre 1 y 15 minutos, con pasos de 1min; de esta de manera se puede controlar la energía luminosa total emitida por los diodos emisores de luz o diodo láser que contribuya en la investigación de una posible solución a la necesidad de acelerar el proceso regenerativo de los tejidos blandos. En la presente tesis se usará una longitud de onda entre 630 – 660nm, luz roja, debido a que en este rango de longitudes de onda se ha demostrado científicamente que se acelera el proceso de regeneración de las células. Se abarcan temas específicos como conocimientos teóricos y prácticos acerca del fundamento clínico de la regeneración celular. Para la implementación del equipo se hizo uso de un microcontrolador, que permitió controlar la energía luminosa emitida por los diodos emisores de luz y el láser diodo hacia los tejidos blandos, controlando la potencia, la frecuencia y el tiempo del tratamiento, además de ayudarnos a implementar un equipo interactivo con el usuario que permita su fácil uso, con una pantalla LCD y un teclado matricial. Se implementó el equipo siguiendo algunas consideraciones teóricas de la norma de seguridad eléctrica para equipos médicos, IEC60601 y la norma IEC 601-2-22, para equipos médicos eléctricos con requerimientos particulares para la seguridad del diagnóstico y terapia de equipos con láser. Se realizaron pruebas eléctricas y se verificó que el margen de error de 10% permitido por la norma no fuese superado. Las pruebas se realizaron a la corriente entregada para la potencia luminosa deseada, frecuencia y tiempo. Los resultados en potencia luminosa fueron: un error mínimo de 0.15% y máximo de 2.744% para los diodos emisores de luz, y un error mínimo de 2.338% y máximo de 8.371% para el diodo láser. Los resultados en frecuencia fueron: un error mínimo de 0.417% y máximo de 0.625%. Por último, el resultado en tiempo fue de un error del 0.01%. Se verifica que se cumplen las normas básicas para la implementación del equipo. Además se observa que el equipo deberá pasar muchas más pruebas para ser comercializado, ya que requiere experimentación clínica lo cual no es parte de esta tesis. Finalmente se realizó una tabulación del costo del proyecto. / Tesis
120

Diseño de un sistema de iluminación LED alimentado por paneles solares aplicado a minería de cielo abierto

Espinoza Robles, Luis Fernando Jesús 27 March 2017 (has links)
La minería es una de las actividades económicas primarias más relevantes en el mundo. En el Perú, viene siendo el impulso para el desarrollo económico actual del país. Como en toda actividad extractiva se busca obtener la mayor producción posible; por eso, es muy frecuente ver el trabajo nocturno en estas, el cual sería muy inseguro e incluso imposible sin la adecuada iluminación para la actividad realizada. La minería de cielo abierto se realiza en amplios espacios, los cuales van cambiando conforme avanza la producción, por ello es necesario el uso de torres de iluminación móviles. Una torre de iluminación es un equipo que se usa para iluminar lugares remotos donde no es posible el acceso a la corriente eléctrica. En la actualidad estos equipos son implementados mediante generadores de corriente eléctrica que funcionan gracias a la quema de combustible. En esta tesis se propone implementar un equipo de iluminación, que obtendrá energía a partir de un sistema fotovoltaico. Dado que es un equipo electrónico alimentado por energía renovable logrará reducir costos de operación y mantenimiento, así como reducirá la contaminación sonora y del medio ambiente. / Tesis

Page generated in 0.0385 seconds