• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 311
  • 40
  • 40
  • 39
  • 39
  • 24
  • 16
  • 6
  • 6
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 314
  • 314
  • 99
  • 73
  • 56
  • 46
  • 40
  • 39
  • 35
  • 35
  • 34
  • 34
  • 33
  • 32
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Desenvolvimento de membranas com capacidade de liberação controlada de fármacos a partir de materiais orgânico-inorgânicos para implantodontia /

Oshiro Junior, João Augusto. January 2014 (has links)
Orientador: Leila Aparecida Chiavacci / Coorientador: Bruno Leonardo Caetano / Banca: Ana Maria Minarelli Gaspar / Banca: Giancarlo Esposito de Souza Brito / Resumo: Dentre as membranas utilizadas para regeneração óssea guiada as membranas reabsorvíveis se destacam por não necessitarem do segundo ato cirúrgico, fato esse que pode ocasionar lesões no tecido estabelecido além do incomodo que o segundo ato cirúrgico em si proporciona ao paciente. Entretanto, não existe no mercado uma membrana considerada adequada. O objetivo deste trabalho foi desenvolver uma membrana a partir de materiais híbridos ureasil-poliéter para regeneração óssea guiada, capaz de isolar o enxerto ósseo e simultaneamente liberar de forma controlada fármacos ou proteínas, resultando assim em uma membrana capaz de melhorar a resposta fisiológica do tecido ósseo diminuindo o tempo de neoformação óssea. Os materiais utilizados foram sintetizados a partir do método sol-gel utilizando os polímeros Poli Oxido de Etileno (POE) e Poli Oxido de Propileno (POP) de diferentes massas moleculares (400, 1900, 2000 g mol-1). O fármaco utilizado como modelo foi o Acetato de Dexametasona. Os resultados de intumescimento na presença de saliva artificial revelaram que com o aumento na proporção de ureasil-POP2000 e ureasil-POE1900 na mistura ocorre um aumento no ganho de massa, contudo esse aumento é mais expressivo para as misturas com ureasil-POE1900. A evolução das curvas de SAXS durante os experimentos de liberação com saliva artificial revela que a mistura formada por ureasil-POP400/POE1900 leva ao deslocamento do pico de correlação para baixos valores de q e ao aumento na intensidade do pico, por outro lado devido à razão hidrofóbica na mistura ureasil-POP400/POP2000 esse deslocamento para baixos valores de q é invariável. O teste de liberação revelou que é possível controlar a velocidade de liberação do fármaco a partir da variação das misturas ureasil-POP400/POP2000 e ureasil-POP400/POE1900. Resultados da análise... / Abstract: Among the membranes used for guided bone regeneration the resorbable membranes stand out for do not need the second surgery, a fact that can cause tissue damage beyond uncomfortable that the second surgery itself provides the patient.However, there is no on the market a membrane considered appropriate. The objective of this study was to develop a membrane from hybrid materials ureasil polyether for guided bone regeneration, able to isolate the bone graft and simultaneously drug release controlled or protein, resulting in a membrane capable of improving the physiological response of the tissue bone decreasing the bone formation. The materials used were synthesized from solgel method using polymers poly ethylene oxide (POE) and poly propylene oxide (POP) of different molecular weights (400, 1900, 2000 g mol-1).The drug used as model was dexamethasone acetate. The results of swelling in the presence of artificial saliva showed that with the increase in the proportion of ureasilPOP2000 and ureasil POE1900 in the mixture occurred an increasing mass, but this increase is more significant for mixture with the ureasil-POE1900.The evolution of SAXS curves during the release experiment with artificial saliva reveals that the mixture formed by ureasil-POP400/POE1900 leads to displacement of the correlation peak for low values of q and the increase in the intensity of the peak but the reason hydrophobic in the mix ureasilPOP400/POP2000 this displacement for low values of q is invariable. The release test showed that it is possible to control the release rate of the drug from the variation of the mixtures and ureasil-POP400/POP2000 ureasilPOP400/POE1900. Results of the microtomography showed that bone defects containing the ureasil-polyether membranes tested showed bone growth statistically similar to bone defects containing commercial collagen membrane (Bio-Gide, Geistlich Pharma). / Mestre
182

Matrizes de quitosina-colágeno podem regular as atividades biológicas de células tronco mensenquimais adiposas para a engenharia de tecidos /

Zotarelli Filho, Idiberto José. January 2013 (has links)
Orientador: Gustavo Orlando Bonilla Rodriguez / Banca: Marinônio Cornélio Lopes / Banca: Rubens Camargo Siqueira / Resumo: Matrizes de quitosana e colágeno podem oferecer nicho biológico para o crescimento de células-tronco derivadas do tecido adiposo (ADSC). O objetivo deste trabalho foi caracterizar as propriedades físicoquímicas das matrizes e sua biocompatibilidade com ADSC, bem como suas interações e influências diretas das matrizes sobre o comportamento da ADSC. A metodologia incluiu o tratamento enzimático de tecido adiposo obtido por lipoaspiração com colagenase IV, imunofenotipagem, cinética de crescimento das células, estudos de biocompatibilidade das matrizes analisadas pela atividade de fosfatase alcalina (AP), determinação de óxido nítrico (NO) por macrófagos e imagens das matrizes por microscopia óptica e eletrônica de varredura. A concentração de reticulação de genipina e glutaraldeído foi avaliada por ensaios de ninidrina, testes de solubilidade e de degradação das matrizes. Os melhores resultados foram obtidos com genipina a 0,5 %. Após nove expansões a viabilidade foi de 99 % e o tempo de duplicação da população de células diminuiu de sete para dois dias. Os resultados mostraram que as matrizes são biocompatíveis, exibem propriedades físicas e químicas necessárias para as células e são fortes estimuladoras de proteínas de sinalização (fosfatase alcalina) e de outras moléculas (NO), que são importantes no processo de regeneração tecidual. Portanto, as matrizes podem proporcionar um nicho biológico para adesão, proliferação e controle das atividades das ADSC / Abstract: Scaffolds of chitosan and collagen can offer a biological niche for the growth of adipose derived stem cells (ADSC). The objective of this work was to characterize the physico-chemical properties of the scaffolds and the ADSC, as well as their interactions to direct influences of the scaffolds on the behavior of ADSC. The methodology included an enzymatic treatment of fat obtained by liposuction by collagenase IV, ASDC immunophenotyping, cell growth kinetics, biocompatibility studies of the scaffolds analyzed by the activity of alkaline phosphatase (AP), nitric oxide (NO) determination, and images of both optical and scanning electron microscopy of the matrices. The extent of the crosslinking of genipin and glutaraldehyde was evaluated by ninhydrin assays, solubility tests and degradation of the matrices. The best results were obtained with 0.5 % genipin. After nine expansions viability was 99 % and the population doubling time decreased from seven to two days.The results showed that the matrices are biocompatible, exhibit physical and chemical properties needed to house cells in vivo and are strong stimulators of signaling proteins (alkaline phosphatase) and other molecules (NO) which are important in tissue regeneration. Therefore, the matrices provide a biological niche for ADSC adhesion, proliferation and cells activities / Mestre
183

Avaliação da degradação de elásticos ortodônticos intraorais de látex / Force extension relaxation of medium force orthodontic latex elastics

Daniel Jogaib Fernandes 10 September 2009 (has links)
Avaliou-se a taxa de degradação de elásticos ortodônticos de látex de diferentes fabricantes e diâmetros em diversos intervalos de tempo. Grupos de 15 elásticos de força média dos fabricantes AmericanOrthodontics (Sheboygan, Wis, EUA), Tp (La Porte, IN, EUA), Morelli (Sorocaba, SP, Brasil) e Uniden (Sorocaba, SP, Brasil); de diâmetros 3/16, 1/4 e 5/16 foram analisados nos intervalos de 0,1,3,6,12 e 24 horas, totalizando-se 1080 espécimes. Os elásticos foram estirados individualmente à distância de 30mm, respeitando-se o intervalo de um minuto entre cada estiramento. Os materiais foram acondicionados imersos em água deionizada à 37C. Realizou-se leitura das forças na máquina de ensaios Emic DL 500 (Emic Co, Sao Paulo, Brasil) à velocidade de 30 mm/min, com uma célula de 2Kg (Emic Co, Sao Paulo, Brasil). A leitura de cada elástico consumiu aproximadamente um minuto. Teste Kruskal-wallis com correções por Dunns aferiu significância estatística dos resultados. Foram observadas diferenças entre os grupos analisados, exceto às marcas Morelli e Tp. Foram significativas as inferências das variáveis tempo e marca comercial. Em 0 hora, a relação entre as forças geradas foi Morelli>AO>Uniden>Tp para elásticos 3/16 (p=0,0016) e 1/4 (p=0,0016) e, de Morelli>AO>Tp>Uniden para elásticos 5/16 (p=0,0087). Após 24 horas, as porcentagens de degradação dos elásticos foram AO>Morelli>Uniden>Tp no diâmetro 3/16; AO>Tp>Morelli>Uniden no diâmetro 1/4 e Tp>AO>Uniden>Morelli para elásticos de diâmetro 5/16. O comportamento no intervalo de 0-24 horas demonstrou uma queda acentuada no período de 0-3 horas, um ligeiro aumento em 3-6 horas, seguido de uma queda progressiva no intervalo de 6-24 horas. / The purpose of this study was to evaluate the force relaxation of different brands and diameters of latex elastics occurring during different times. Groups of 15 medium forces elastics from manufacturers: American Orthodontics (Sheboygan, Wis, USA), Tp (La Porte, IN, USA), Morelli Orthodontics (Sorocaba, SP, Brazil) and Uniden Orthodontics (Sorocaba, SP, Brazil) with diameters: 3/16, 1/4 and 5/16 inch size were tested at 0,1,3,6,12,24 hours, making a total of 1080 specimens. An apparatus was designed to simulate oral environments during elastics stretching. The forces were read after 1,3,6,12 and 24-hour periods in Emic testing machine (Emic Co, Sao Paulo, Brazil) with 30 mm/min cross-head speed and load cell of 2Kg Emic force (Emic Co, Sao Paulo, Brazil). Kruskal-Wallis and Dunns tests were used to identify statistical significance. Overall, there were statistically differences among the different manufacturers at all observation intervals, except between Morelli and Tp. Significantly variability were seen in Morelli and Uniden force delivery. The relationships among loads at 0-hour time period were as follows: Morelli>AO>Uniden>Tp for 3/16 (p=.0016) and 1/4 elastics (p=.0016) and Morelli>AO>Tp>Uniden for 5/16 elastics (p=.0087). The forces relaxation over the 24-hour time period were AO>Morelli>Uniden>Tp for 3/16 elastics; AO>Tp>Morelli>Uniden for 1/4; and Tp>AO>Uniden>Morelli for 5/16 elastics.The force decay pattern show a notable drop-off of forces during 0-3 hours, a slight increase in force values from 3-6 hours and a progressive force decay was seen over 6-24 hours.
184

Desenvolvimento de técnica de deposição de hidroxiapatita pelo método biomimético na superfície polietileno de ultra-alto peso molecular para aplicação como biomaterial

Fook, Marcus Vinícius Lia [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T20:01:16Z : No. of bitstreams: 1 fook_mvl_dr_araiq.pdf: 2682702 bytes, checksum: 59290f39520b7fb33aa9f472d48b6b7f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As cirurgias de quadril têm-se tornado bastantes comuns no mundo, principalmente devido ao aumento da expectativa de vida e pelo sucesso do procedimento cirúrgico. Nos Estados Unidos são mais de 500.000 procedimentos cirúrgicos por ano com estimativas de que este número seja o dobro, 1.000.000, para o mundo. O desafio de substituir tecidos rígidos deve se basear no princípio de que se devem desenvolver materiais que mais se aproximem das propriedades do tecido natural em relação às propriedades mecânicas e possuam adequada interação biológica. Dentre os materiais desenvolvidos para serem aplicados por longo tempo, apenas um pequeno grupo tem aplicação industrial; cromo-cobalto, titânio e suas ligas, platina, alumina, hidroxiapatita, silicone, politetrafluoretileno, poliéster, polietileno e polimetilmetacrilato. Estes materiais apresentam, dentre os materiais de suas respectivas classes, as melhores propriedades mecânicas e resistência à corrosão ou degradação. Com uma extensa variedade de materiais, métodos de obtenção e combinações, os procedimentos de colocação do implante ocorrem de duas maneiras: com uso de cimento a base de polimetilmetacrilato - PMMA e sem o uso de cimento. No caso das próteses cimentadas, o desgaste do PMMA e a liberação de monômeros de MMA, combinado com o efeito térmico provocado pela reação de polimerização ocorrida no local estão associados ao elevado percentual de revisão das cirurgias (80%). Esta investigação científica foi concebida a partir desta limitação clínica. No estágio tecnológico atual a substituição da cabeça do fêmur é feita com polietileno de ultra-alto peso molecular - PEUAPM. O polímero, por sua vez, é preso ao osso do quadril através de parafusos e cimentos ósseos (à base de metacrilato). Estes cimentos são indesejáveis por não serem osteointegrados e pela potencialidade nociva dos resíduos que são liberados. / The hip surgeries have become very usual around the world mainly due to the increase in the life expectation and the success in the surgical procedures. In the United States alone the number is over 500,00 surgical procedures per year and it is estimated double the number for the rest of the world. The challenge of substituting hard tissues should be based on the principle that it should be developed materials which are most similar to the properties of natural tissues concerning the mechanical properties and have adequate biological interaction. Among the materials developed to be applied for long time, only a small group has industrial application; chrome-cobalt, titanium and its alloys, platinum, alumina, hydroxyapatite, silicone, politetrafluoroethylene, polyesther, polyethylene and polymetylmethacrylate. Those materials show, among the materials of their respective categories, the best mechanical properties and resistance to corrosion or degradation. With a large variety of materials and methods of obtaining and combinations, the procedures of inserting the implant occur in two ways: with the use of cement compounded by PMMA and without the use of cement. In the case of the cemented prostheses, the wear of PMMA and the liberation of monomers of MMA, combined with the thermal effect caused by the reaction of polymerization occurred in situ, are associated with the high percentage of surgery review (80%). This scientific investigation was conceived from that clinical limitation. At the present technological stage the substitution of the femoral head is made with ultrahigh molecular weight polyethylene - UHMWPE. That polymer, consequently, is attached to the bone of the hip by screws and bone cements (compounded by methacrylates). Those cements are undesirable because they are not osseointegrated and because of the harmful potentiality of the residue that is liberated.
185

Utilização de células de linhagem odontoblástica (MDPC-23) em estudos de citotoxicidade e na avaliação do efeito de fatores de crescimento sobre a expressão de genes específicos /

Souza, Pedro Paulo Chaves de. January 2005 (has links)
Resumo: Este estudo teve como objetivo geral utilizar células da linhagem MDPC-23 em testes de citotoxicidade de materiais e na investigação dos efeitos de proteínas bioativas no estímulo da síntese de componentes da matriz dentinária. Os objetivos específicos foram avaliar o efeito citotóxico de soluções utilizadas na lavagem de paredes cavitárias e de materiais dentários recomendados para aplicação em dentina sobre células de linhagem odontoblástica MDPC-23. Também foi intuito avaliar o efeito do concentrado de proteínas extraídas da dentina de coelho sobre a expressão de genes específicos. Este trabalho, apresentado na forma de três artigos científicos, utilizou a técnica de MTT para avaliar o efeito citotóxico de soluções de CLX em variadas concentrações sobre as células MDPC-23. Esta técnica foi utilizada também para a investigação do efeito citotóxico de três diferentes cimentos de ionômero de vidro modificados por resina: Vitrebond (VB); Vitremer (VM); e RelyX Luting Cement (RX), associada ao teste de implantação destes materiais resinosos no tecido conjuntivo subcutâneo de ratos. A expressão dos genes que codificam para colágeno tipo-1 e fibronectina nas células expostas ao concentrado de proteínas extraídas da dentina de coelhos foi avaliada por RT-PCR. Os resultados demonstraram que a CLX é citotóxica às células da linhagem MDPC-23 de maneira dose-dependente. Também foi demonstrado que os cimentos de ionômero de vidro são biocompatíveis ao tecido conjuntivo subcutâneo de ratos, apesar de apresentarem diferentes graus de citotoxicidade sobre as células odontoblastóides. As proteínas bioativas extraídas da dentina de coelhos apresentaram efeito estimulatório na expressão de genes que codificam para colágeno tipo-1 e fibronectina. Pode-se concluir que as células MDPC-23 são um modelo que pode ser utilizado nos testes de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The general aim of this in vitro and in vivo study was to evaluate the cytotoxicity of rinsing solutions and dental materials as well as to determine the expression of genes related with the dentinogenesis. The specific objectives were to evaluate the cytotoxicity effects of rinsing solutions used to clean cavity walls and dental materials used to restore dental cavities. The effects of EDTA soluble dentin proteins (members of TGF-â superfamily) on specific gene espression was also evaluated. For this porpose three scientific papers were prepared: 1) MTT assay was employed to investigate the cytotoxic effects of different concentrations of chlorhexidine to MDPC-23 cells as well as to; 2) to determine the cytotoxicity of three different resin-modified glass-ionomer cements (RMGIC): Vitrebond (VB); Vitremer (VM); and RelyX Luting Cement (VM). The results of this in vitro study was compared to the in vivo study in which RMGICs were implanted into the connective tissue of rats; 3) Type-1 collagen and fibronectin gene expression on cells exposed to EDTAsoluble dentin proteins was assessed by means of semi-quantitative RT-PCR. The results demonstrated that chlorhexidine is cytotoxic to MDPC-23 cells in a dose-dependent way. It was also demonstrated that RMGICs are biocompatible following implantation into surgical pockets prepared in the dorsal connective tissue of rats in spite of the different degrees of in vitro cytotoxicity presented by these materials to MDPC-23 cells. The stimulatory effects of the bioactive molecules on the expression of the genes that encodes to type-1 collagen and fibronectin was clearly demonstrated. Based on the experimental conditions, it was concluded that MDPC-23 cells are suitable model to be used on cytotoxicity tests of dental materials and rinsing solutions as well as to evaluate the dentinogenesis mechanisms. / Orientador: Carlos Alberto de Souza Costa / Coorientador: Claudio Miguel da Costa Neto / Banca: Maria Aparecida de Andrade Moreira Machado / Banca: Elisa Maria Aparecida Giro / Mestre
186

Desenvolvimento de uma nova liga quaternária Ti25Ta25Nb3Sn para aplicações odontológicas /

Seixas, Maurício Rangel. January 2015 (has links)
Orientadora: Ana Paula Rosifini Alves Claro / Banca: Marcelo Santos Pereira / Banca: Roberto Zenhei Nakazato / Banca: Estevão Tomomitsu / Banca: Cristiane Aparecida Assis Claro / Resumo: Materiais biometálicos são usados para aplicações biomédicas, como cardiovasculares, ortopédicas e odontológicas, devido as suas propriedades, como biocompatibilidade e adequadas propriedades mecânicas, como resistência à corrosão em ambiente corpóreo. E pela combinação de resistência ao desgaste e baixo módulo de elasticidade. Entretanto, apesar da sua excelente resistência a corrosão estes materiais podem ser corroídos quando expostos em ambiente oral. A liberação de ions metálicos pode produzir toxicidade indesejável, principalmente em ligas contendo níquel como NiTi. Nesse estudo, uma nova liga quaternária contendo elementos não citotóxicos Ti, Ta, Nb e Sn, foi processada e avaliada. As ligas foram processadas em forno de arco voltáico em atmosfera de argônio, a partir de chapas dos elementos comercialmente puros. Os lingotes foram fundidos, refundidos por pelo menos dez vezes e homogeneizados (1000 ° C para 86,4 ks) para eliminar a segregação, após trabalho a frio em prensa rotativa. As fases foram avaliadas por análises de XDR (Difração de raios X). Teste de microdureza e de tração foram realizado para avaliar as propriedades mecânicas. Comportamento de corrosão foi investigado em solução de fluoreto em polarização eletroquímica. Módulo de elasticidade e citotoxicidade da nova liga também foram avaliados. Neste estudo, para a liga quaternário Ti25Ta25Nb3Sn a estabilização da fase beta foi mantida. O módulo de elasticidade de Ti25Ta25Nb3Sn (65GPa) foi menor do que do titânio (105 GPa) e Ti6Al4V (110 GPa), sendo ligeiramente maior do que Ti25Ta25Nb liga (55GPa). A adição de Sn inibiu o duplo escoamento verificado na liga ternária Ti25Ta25Nb. Estudos eletroquímicos mostraram que o filme de óxido passivo formado ficou estável sobre a superfície da liga Ti25Ta25Nb3Sn e a não-toxicidade foi ... ( Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Metallic biomaterials have been used for biomedical applications, such as cardiovascular, orthopaedics and orthodontics, due to properties. However, although their corrosion resistance these materials can be corrode when exposed oral environment. Metals ion release can produce undesirable toxicity, principally in alloys containing Ni, as NiTi. In this study, a new quaternary alloys with non-cytotoxic elements Ti, Ta, Nb and Sn was processed and evaluated. Alloys were processing in arc melting furnace with argon atmosphere from sheets of commercially pure elements. Ingots will be melted and re-melted ten times at least and homogenized (1000°C for 86.4 ks) for eliminated segregation chemical after cold-worked by swaging. Phases were evaluated by XRD (X-ray diffraction) analysis. Microhardness and tension test was carried out to evaluate mechanical properties. Corrosion behaviors was investigated in fluoride solution by electrochemical polarization. Young's modulus and cytotoxicity of the new alloy were also evaluated. In our study, for quaternary alloy Ti25Ta25Nb3Sn the stabilization of beta phase was maintained. It was observed that the elastic modulus of Ti25Ta25Nb3Sn (65GPa) was lower than CP Ti (105 GPa) and Ti6Al4V (110 GPa) and slightly higher than Ti25Ta25Nb (55GPa) alloy. The addition of Sn suppressed the double yielding verified on ternary alloy Ti25Ta25Nb.Electrochemical studies showed that stable passive oxide film was formed on the Ti25Ta25Nb3Sn surface and non-toxicity was observed after MTT assays. Results obtained showed that Ti25Ta25Nb3Sn alloy is indicated for biomedical applications / Doutor
187

Modificação da superfície da liga experimental Ti10Mo8Nb empregando oxidação anódica : estudos in vitro /

Carobolante, João Pedro Aquiles. January 2017 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Claudia Eliana Bruno Marino / Banca: Carlos Roberto Grandini / Resumo: Titânio e suas ligas são amplamente empregados em aplicações biomédicas, devido a sua biocompatibilidade e excelentes propriedades de volume, como resistência mecânica. As ligas de titânio tipo β com baixo módulo de elasticidade, como Ti10Mo8Nb, são indicadas para amenizar o efeito "stress shielding", característico da interface implante/osso. No entanto, quando materiais bioinertes são inseridos no corpo humano não induzirão uma resposta específica. As técnicas de modificação de superfície, como crescimento de nanoestruturas de TiO2, são utilizadas para alterar as propriedades de superfície desses materiais permitindo melhor resposta. O objetivo dessa pesquisa é a modificação de superfície da liga experimental Ti10Mo8Nb a partir do crescimento de nanoestruturas de TiO2. Os lingotes da liga experimental Ti10Mo8Nb foram obtidos a partir da fusão dos metais puros em forno a arco voltaico. A oxidação anódica potenciostática foi realizada utilizando um eletrólito formado por glicerina e H2O (1:1, em vol.) com adição de 2,7 % (m/v) de NH4F sob 20 V durante 3 h, a temperatura ambiente. Após o tratamento as amostras foram calcinadas. A superfície da liga foi analisada por microscopia eletrônica de varredura (MEV), difração de raios X (DRX), ângulo de contato, medidas da energia de superfície, espectroscopia de raios X por dispersão em energia (XPS). Estudos in vitro, como adesão celular e bacteriana, foram realizados para avaliar a resposta desse tratamento. A liga Ti10Mo8Nb apresen... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and its alloys have been widely used as biomedical material due their biocompatibility and excellent bulk properties, such as mechanical strength. β titanium alloys with low modulus of elasticity, such as Ti10Mo8Nb, are suitable to relieve the stress shielding effect that occurs in the interface implant/bone. However, when these materials are inserted inside human body the surface properties will not induce a specific response. Surface modifications techniques can be used for change the inert surface of these alloys, e.g. TiO2 nanostructure growth by using anodic oxidation. The purpose of this research is the surface modification of Ti10Mo8Nb experimental alloy by using TiO2 nanostruture growth. Ingots of Ti10Mo8Nb experimental alloy were produced by fusion from sheets of molybdenum, niobium and titanium commercially pure in arc melting furnace under argon atmosphere. The potentiostatic anodic oxidation was performed using an electrolyte formed of glycerol and H2O (1: 1 by vol.) with addition of 2.7% (w/v) NH4F under 20 V for 3 h at room temperature. After the surface treatment, the samples were annealing. The surface of the alloy was analyzed by scanning electron microscopy (SEM), X-ray diffraction (XRD), contact angle, surface energy measurements, energy dispersive X-ray spectroscopy (XPS). In vitro studies, such as cell and bacterial adhesion, were performed to evaluate the response of this treatment. The Ti10Mo8Nb alloy exhibited beta phase after the processing, and also occurred a decrease in β-transus temperature. After the surface treatment a nanoporous layer of TiO was obtained. The anatase phase was found in the annealed samples (450 °C for 3 hours). In vitro analyzes showed cell growth viability and decreased bacterial proliferation due to larget specific surface area / Mestre
188

Análise da rota de processamento da liga Ti-30T visando a aplicação biomédica /

Konatu, Reginaldo Toshihiro. January 2014 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Coorientador: Luiz Rogério de Oliveira Hein / Banca: Angelo Caporalli Filho / Banca: Maria Ismênia Sodero Toledo Farria / Resumo: Ligas de titânio são utilizadas para aplicações biomédicas devido as excelentes propriedades como a alta resistência à corrosão, biocompatibilidade e propriedades mecânicas. No presente trabalho, foram analisadas as microestruturase as propriedades mecânicas daliga Ti-30Ta e em amostras deformadas com diferentes graus de compressão. A liga foi obtida pela fusão dos metais puros em um forno a arcovoltaico com atmosfera inerte de argônio. O material obtido foi homogeneizado em um forno tubular a 1000 °C por 24 h e deformadas a friopelo processodeforjamento rotativo para obter barras de 13 mm de diâmetro. A liga foi avaliada utilizadastécnicas de difração de raios-X (DRX) em temperatura ambiente e com aquecimento, calorimetria diferencial de varredura(DSC), microscopia eletrônica de transmissão (TEM), microdureza e compressão de corpos de provas em diferentes graus de deformação. As amostras foram deformadas com taxas graus de 19%, 22% e 43% e analisadas, usando as técnicas de DRX,microscopia óptica, microdureza. A liga apresentou transformação alotrópica a uma temperatura próxima de 650°C, e microestrutura do tipo α', a deformação da amostra resultou em cisalhamento na amostra de 43%, as amostras apresentaram microdureza de 250, 269, 286 e 280HV para as amostras sem deformação, 19%, 22%e 43% de deformação / Abstract: Titanium and its alloys have been used for biomedical applications due their excellent properties, such as high corrosion resistance, biocompatibility and mechanical proprieties. In this work, the microstructure and mechanical proprieties of Ti-30Taand deformeds amples with different degrees of compression were analyzed The in gots were obtained in a arc melting furnace inan argon atmosphere. In gots were homogenized at 1000 ºCin a tubular furnace with argon atmosphere for 24 hours and than they were cold worked by swaging. and samples with 13 m mindiameter were obtained. The alloy was evaluated by X-raydiffraction (XRD), Heat treatment X ray diffraction (HTXRD)and differential scanning calorimetrical (DSC), transmission electron microscopy(TEM), micro hard nessand compression test with different deformations. The samples were forging at reductionratiosof 19%, 22% and 43%. After this deformation,its microstructure were evaluated by optical microscopy, X-ray diffraction(XRD)and micro hardness in each condition. The alloy show a allotropic transformation at 650 °C, and α' microstructure. The sample that was compressed with 43% shear and the others samples ( 19%, 22%) don't change their microstructure. the samples without deformation, 19%, 22% and 43% result 250, 269, 286, 280 HV / Mestre
189

Avaliação do reparo de defeitos críticos em calvária de ratos preenchidos com a vitrocerâmica Biosilicato® sintetizada pelo processamento sol-gel : análises histológica e imuno-histoquímica /

Silva, Raquel Barroso Parra da. January 2019 (has links)
Orientador: Mariza Akemi Matsumoto / Coorientador: Mariza Akemi Matsumoto / Coorientador: Idelmo Rangel Garcia Júnior / Banca: Roberta Okamoto / Banca: André Luís da Silva Fabris / Resumo: Os materiais vítreos podem ser processados por diferentes rotas, dentre elas a convencional por fusão e solidificação ou por rota sol-gel, o que melhora sua bioatividade. O objetivo do presente estudo foi o de avaliar o comportamento biológico da vitrocerâmica Biosilicato® sintetizada pelo processamento sol-gel durante o processo de reparo ósseo em modelo animal. Para tanto, foram utilizados 30 ratos Albinus Wistar, machos, com cerca de três meses de idade e pesando em média 450 gramas. Os mesmos foram submetidos a procedimento cirúrgico para confecção de um defeito de 5mm de diâmetro no osso parietal direito e divididos em 2 grupos, de acordo com o biomaterial estudado: Grupo BS - defeitos preenchidos com Biosilicato® particulado convencional (180-212 µm), e Grupo BG - defeitos preenchidos com Biosilicato® particulado produzido via rota sol-gel (180-212 µm). Após os períodos de 7, 21 e 45 dias, os animais foram submetidos à eutanásia para remoção dos espécimes para serem preparados e submetidos para análise microscópica morfológica e imuno-histoquímica. Aos 7 dias do grupo BS observaram-se partículas do biomaterial circundadas por tecido de granulação, no centro do defeito próximo e tecido ósseo neoformado próximo as suas paredes. Aos 21 dias, presença marcante de CGMs em contato com o biomaterial e aos 45 dias, biomaterial ora substituído por leucócitos MNs e CGMs ora circundado por tecido conjuntivo. Já no grupo BG aos 7 dias observaram-se numerosas partículas arredondadas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The vitreous materials can be processed by different routes, among them the conventional one by fusion and solidification or by route sol-gel, which improves their bioactivity. The objective of the present study was to evaluate the biological behavior of the glass-ceramic Biosilicato® synthesized by sol-gel processing during the bone repair process in animal model. For this, 30 male Albinus Wistar rats were used, about three months old and weighing on average 450 grams. They were submitted to a surgical procedure to make a 5mm diameter defect in the right parietal bone and divided into 2 groups according to the biomaterial studied: BS group - defects filled with conventional particulate biosilicate (180-212 μm), and Group BG - defects filled with particulate Biosilicate® produced via sol-gel route (180-212 μm). After the 7, 21 and 45 day periods, the animals were submitted to euthanasia to remove the specimens to be prepared and submitted for microscopic morphological and immunohistochemical analysis. At 7 days of the BS group biomaterial particles were observed surrounded by granulation tissue, close to the defect wall and noticed if neoformed bone tissue at 21 days, the presence of CGMs in contact with the biomaterial and at 45 days, biomaterial ora replaced by leukocytes MNs and CGMs or surrounded by connective tissue, already in the BG group at 7 days there are numerous rounded biomaterial particles surrounded by granulation tissue at 21 days, presence of CGMs in contact ... (Complete abstract click electronic access below) / Mestre
190

Caracterização da superfície da liga experimental ti25ta25nb3sn após tratamento alcalino : estudos in vitro /

Lima, Marcia Costa Marques. January 2018 (has links)
Orientador: Ana Paula Rosifini Alves Claro / Banca: Laís Regiane da Silva Concílio / Banca: Andrea Carvalho de Marco / Resumo: Titânio e suas ligas são considerados materiais bioinertes e dessa forma técnicas de modificação de superfície podem ser empregadas para uma melhor interação osso/biomaterial. Assim, o presente estudo teve por objetivo avaliar a modificação da superfície da liga experimental Ti25Ta25Nb3Sn a partir do emprego do tratamento alcalino, com vistas à obtenção de uma superfície bioativa. Os lingotes das ligas foram obtidos em forno a arco voltaico e posteriormente foram submetidos a tratamento térmico e forjamento a frio, de tal forma que discos com 10 mm de diâmetro e 3mm de espessura fossem obtidos. Para o tratamento alcalino as amostras foram imersas em solução de NaOH na concentração de 0,5, 1,0 e 1,5M. A morfologia das superfícies das amostras foi avaliada por meio do microscópio eletrônico de varredura e a composição avaliada por espectroscopia de energia dispersiva (EDS). As fases presentes após tratamento foram avaliadas por técnicas de difração de raios-X e a molhabilidade das superfícies a partir do ângulo de contato. Estudos in vitro foram realizados para avaliar a adesão bacteriana e proliferação celular. Os resultados evidenciam a produção de uma estrutura porosa na superfície da liga quando ela foi submetida ao tratamento com NaOH em todas as molaridades usadas. A molhabilidade da superfície apresentou caraterística hidrofílica, o difratograma revelou picos mais intensos após o tratamento alcalino. Verificou também maior quantidade de bactérias nas superfícies porosas ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and its alloys are considered bioinert materials and thus surface modification techniques can be employed for better bone / biomaterial interaction. Thus, the present study aimed to evaluate the surface modification of the experimental alloy Ti25Ta25Nb3Sn to obtain a bioactive surface, from the use of alkaline treatment. The ingots of the alloys were obtained in an arc furnace and afterwards they were subjected to thermal treatment and cold forging, in such a way that disks with 10 mm of diameter and 3 mm of thickness were obtained. For the alkaline treatment the samples were immersed in NaOH solution at the concentration of 0.5, 1.0 and 1.5M. The morphology of the surfaces of the samples was evaluated by scanning electron microscopy and the composition evaluated by dispersive energy spectroscopy (EDS). The phases present after treatment were evaluated by X-ray diffraction techniques and the wettability of the surfaces from the contact angle. In vitro studies were performed to evaluate bacterial adhesion and cell proliferation. The results evidenced the production of a porous structure on the alloy surface when it was subjected to NaOH treatment in all the molarities used. The wettability of the surface presented a hydrophilic character, the diffractogram showed more intense peaks after the alkaline treatment. It also verified a greater amount of bacteria in the porous surfaces resulting from the alkaline treatment and greater cell adhesion with viability without variation between the treatments. It is concluded that the treatment with 1.0M NaOH provides a bioactive surface / Mestre

Page generated in 0.0921 seconds