• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 449
  • 10
  • 3
  • 1
  • 1
  • Tagged with
  • 464
  • 319
  • 247
  • 98
  • 75
  • 68
  • 67
  • 55
  • 55
  • 40
  • 37
  • 35
  • 31
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

A contribuição da tecnologia industrial básica (TIB) no processo de formação e acumulação das capacidades tecnológicas de empresas do setor metal-mecânico. / The contribution of infrastructural technologies (lfT) in the formation and accumulation process of technological capabilities of firms in metal-mechanics industry.

Renato Gallina 29 May 2009 (has links)
Nota-se que cada vez mais a sobrevivência e o crescimento das empresas industriais estão relacionadas com a possibilidade de se oferecer produtos e serviços em conformidade com as mais recentes normas internacionais. Em tal contexto, o domínio das funções tecnológicas da Tecnologia Industrial Básica TIB (metrologia, normalização e avaliação da conformidade) não é somente um requisito para a competitividade de uma empresa, mas também a base para a efetiva acumulação de capacidades tecnológicas, as quais são necessárias para a inovação bem como para o melhoramento contínuo da qualidade dos produtos e serviços. Na literatura especializada, raros são os estudos que analisam a função da TIB no processo de aprendizagem tecnológica de uma empresa. Este trabalho teve a intenção de preencher essa lacuna ao propor um modelo para avaliar e projetar as relações dinâmicas entre TIB e capacidade tecnológica. O objetivo geral deste estudo foi o de analisar a relação entre a TIB e a formação e acumulação das capacidades tecnológicas nas empresas. O estudo foi realizado através de um survey, cujo instrumento de pesquisa foi um questionário aplicado em uma amostra de 103 empresas de diferentes níveis de capacidade tecnológica do setor metalmecânico. Concluiu-se que a TIB contribui com a formação e acumulação das capacidades tecnológicas em todos os níveis e os resultados mostraram que existem associações significativas entre: (i) certificações ISO 9001/TS 16949 com as atividades de engenharia reversa; (ii) certificações ISO 17025 e de produtos com as inovações incrementais em sua linha de produtos; (iii) certificação ambiental ISO 14001 com as inovações radicais em processos/produtos, práticas de just-in-time, Kaizen, TQC/TQM e uso de sistemas integrados de informação; e (iv) sistemas inovadores de medição com as práticas de P&D e relacionamentos com instituições de C&T. / Increasingly, the survival of industrial firms is related to the possibility of offering products and services in conformity with the most recent international standards. However, the mastery of Infrastructural Technologies IfT (metrology, standardization and conformity assessment) is not only a requirement for the international competitiveness of a firm but it is also the basis for the effective accumulation of Technological Capabilities (TC) which are needed for innovation as well as the continuous improvement of the quality of products and services. In the existing literature, rare are the studies that analyze the role of IfT in the technological learning process of a firm. This work intended to fill that gap by proposing a model to assess and project the dynamic interplay between IfT and TC. The aim of this study was to analyze the relationship between IfT and the effective accumulation of TC in the firms. The study was carried out through a survey, whose instrument of research was a questionnaire applied in a sample of 103 firms of different levels of TC in metal-mechanics industry. It can be concluded that the IfT contributes with the effective accumulation of TC in all levels and the results showed that there are significant associations between: (i) accreditations ISO 9001/TS 16949 with the reversal engineering activities; (ii) accreditations ISO 17025 and of certified products in their production lines with incremental innovations in their products; (iii) ambiental accreditation by ISO 14001 with radical innovations in products/processes, activities of JIT, Kaizen, TQC/TQM and the use of information integrated systems; and (iv) innovatory systems of measurement with P&D practices and relationships with C&T institutions.
202

Análise de incerteza de um sistema automatizado para ensaios de aspersores de irrigação / Analysis of uncertainty of an automated system for testing irrigation sprinklers

Ezequiel Saretta 17 May 2016 (has links)
Ensaios de distribuição de água de aspersores são convencionalmente realizados manualmente, requerendo tempo e mão de obra treinada. A automação desses ensaios proporciona redução da demanda por esses recursos e apresenta potencial para minimizar falhas e/ou desvios de procedimento. Atualmente, laboratórios de ensaio e calibração acreditados junto a organismos legais devem apresentar em seus relatórios a incerteza de medição de seus instrumentos e sistemas de medição. Além disso, normas de ensaio e calibração apresentam especificação de incerteza aceitável, como a norma de ensaios de distribuição de água por aspersores, ISO 15886-3 (2012), a qual exige uma incerteza expandida de até 3% em 80% dos coletores. Os objetivos deste trabalho foram desenvolver um sistema automatizado para os ensaios de aspersores em laboratório e realizar a análise de incerteza de medição, para sua quantificação nos resultados de ensaio e para dar suporte ao dimensionamento dos tubos de coleta. O sistema automático foi constituído por um subsistema de gerenciamento, por meio de um aplicativo supervisório, um de pressurização e um de coleta, por meio de módulos eletrônicos microprocessados desenvolvidos. De acordo com instruções do sistema de gerenciamento o sistema de pressurização ajustava a pressão no aspersor por meio do controle da rotação da motobomba, e o sistema de coleta realizava a medição da intensidade de precipitação de água ao longo do raio de alcance do aspersor. A água captada por cada coletor drenava para um tubo de coleta, que estava conectado a uma das válvulas solenoides de um conjunto, onde havia um transmissor de pressão. Cada válvula era acionada individualmente numa sequência para a medição do nível de água em cada tubo de coleta, por meio do transmissor. Por meio das análises realizadas, as menores incertezas foram obtidas para os menores diâmetros de tubo de coleta, sendo que se deve utilizar o menor diâmetro possível. Quanto ao tempo de coleta, houve redução da incerteza de medição ao se aumentar a duração, devendo haver um tempo mínimo para se atingir a incerteza-alvo. Apesar de cada intensidade requer um tempo mínimo para garantir a incerteza, a diferença mínima de nível a ser medida foi a mesma. Portanto, para os ensaios visando atender a incerteza, realizou-se o monitoramento da diferença de nível nos tubos, ou diferença de nível, facilitando a realização do ensaio. Outra condição de ensaio considerou um tempo de coleta para 30 voltas do aspersor, também exigido pela norma ISO 15886-3 (2012). A terceira condição considerou 1 h de coleta, como tradicionalmente realizado. As curvas de distribuição de água obtidas por meio do sistema desenvolvido foram semelhantes às obtidas em ensaios convencionais, para as três situações avaliadas. Para tempos de coleta de 1 h ou 30 voltas do aspersor o sistema automático requereu menos tempo total de ensaio que o ensaio convencional. Entretanto, o sistema desenvolvido demandou mais tempo para atingir a incerteza-alvo, o que é uma limitação, mesmo sendo automatizado. De qualquer forma, o sistema necessitava apenas que um técnico informasse os parâmetros de ensaio e o acionasse, possibilitando que o mesmo alocasse seu tempo em outras atividades. / Sprinkler water distribution tests are usually done manually, requiring time and trained labor. Automation of these tests allows saving such resources, and offers potential to minimize failures and/or procedure deviations. Nowadays, calibration and testing laboratories accredited by legal bodies have to present the uncertainty of their instruments and measurement systems. Besides, testing and calibration standards specify acceptable uncertainty, as the standard for sprinkler water distribution test, ISO 15886-3 (2012), which requires an expanded uncertainty up to 3% for 80% of the collectors. The purposes of this work were to develop an automated system for testing sprinkler at laboratory, and perform the analysis uncertainty of measurement, to quantify its magnitude on the testing results, and to support the sizing of collection tubes. The automatic system consisted of a management system, by the supervisory program, a pressurization system, and a collection system, by microprocessed electronic modules developed. According to instructions of the management system, the pressurization system adjusted pressure at the sprinkler by controlling pump rotation, and the collection system measured water application rate through the sprinkler radius. The water from each collector drained to a collecting tube, which was connected to a manifold of valves that contained a pressure transmitter. Each valve was individually triggered in sequence to allow measuring water level within each collection tube, by the transmitter. The analysis of uncertainty showed that the lower diameters of collection tubes presented the lower uncertainty, hence lower diameters should be used when possible. For the collection time, uncertainty decreased as time increased, and should be a minimum value to reach the target uncertainty. Although each application rate requires a minimum time to reach uncertainty, the difference of pressure to be measured stayed the same. Thus, for the tests addressing uncertainty, the difference of pressure was monitored, facilitating the test. Another test condition considered the collection time for 30 laps of the sprinkler, also required by ISO 15886-3 (2012). The third condition considered 1 h of collection, as traditionally done. Water distribution curves obtained from the automated system were similar as those of the conventional tests, for the three situations evaluated. For durations of 1 h or 30 laps of the sprinkler, the automated system required lower total time than the conventional test. However, the system developed demanded more time to perform the test to reach the maximum uncertainty, which is a limitation, even been automatized. In any case, a technician was required just to set parameters and then start the system, so he could allocate his time for other activities.
203

Integração metrologia, CAD e CAM: uma contribuição ao estudo de engenharia reversa. / Metrology, CAD and CAM integration: a contribution to reverse engineering study.

Amauri Bravo Ferneda 19 February 1999 (has links)
Engenharia reversa é o conceito de se produzir uma peça tomando como base um original ou modelo físico existentes, sem o uso de desenhos de engenharia. Empresas se voltam para a tecnologia da Engenharia Reversa como um complemento valioso para toda a gama de ferramentas CAD/CAM que elas possuem, devido às dificuldades encontradas quando se necessita trabalhar com superfícies de forma livre. Desta forma, faz-se necessária uma ferramenta que proporcione a inserção das formas deste modelo em um sistema CAD, de forma que se possa usufruir de todas as possibilidades, oferecidas por ele. Neste trabalho, é apresentada uma revisão bibliográfica que aborda a engenharia reversa desde sua origem até as técnicas avançadas existentes atualmente, ou seja, apresentando equipamentos e sistemas específicos usados atualmente para a prática de engenharia reversa. Mostra-se um sistema de engenharia reversa, que foi projetado e implementado realizando a integração desde uma máquina de medir 3 coordenadas até um centro de usinagem CNC com o auxílio de um software CAD comercial, o qual possui módulo de CAM integrado. São apresentados também 3 estudos de casos. / Reverse engineering is the concept of making a part based on an original or existing physical model, without engineering drawings. Companies are using reverse engineering technology as a valuable complement to many of their CAD/CAM tools, due to their difficulties of working with free-form surfaces. It is necessary a tool which provides the insertion of the model forms in the CAD system, therefore enabling to take advantages of all possibilities offered by the system. The Reverse Engineering has developed beyond the traditional copy milling. It is presented a review of the reverse engineering since its origin until recent advanced techniques, where the equipments and specific systems used for reverse engineering practice nowadays are showed. In this work a reverse engineering system has been designed and implemented, which is accomplished by the integration from the coordinate measuring machine until a CNC machining center, by using a commercial CAD software with integrated CAM module. In order to validate the system developed, three case studies are also presented.
204

Influência da incerteza de medição no uso de cartas de controle / Influence of measurement uncertainty in the usage of control charts

Hack, Pedro da Silva January 2012 (has links)
A incerteza de medição ainda é tema de estudo e desenvolvimento, mesmo quase vinte anos após o lançamento do ISO GUM, que definiu um padrão internacional para o cálculo de incerteza. Mesmo assim, poucos estudos tratam da interface entre a incerteza de medição e outros aspectos da qualidade industrial, em especial ferramentas de controle de processo como cartas de controle. Assim, o objetivo deste trabalho é estudar os efeitos da incerteza em cartas de controle e identificar sob quais situações de aplicação ela exerce maior influência. Foi feito um mapeamento dos artigos publicados entre 2004 e 2010 sobre incerteza de medição, para identificar quais as metodologias de cálculo e abordagem são mais utilizadas. Na sequência, foi desenvolvido um método incluir nas cartas de controle a incerteza do sistema de medição, modificando as probabilidades de erros tipo I e tipo II. Finalmente, foi elaborada uma simulação computacional utilizando o método desenvolvido, para que fosse possível analisar quais as situações nas quais a incerteza de medição deve ser obrigatoriamente considerada e quais ela pode ser negligenciada. / The measurement uncertainty is still subject of study and development, even almost twenty years after the release of the ISO GUM, which set an international standard for the its calculation. Still, few studies have addressed the interface between the measurement uncertainty and other aspects of industrial quality, in particular process control tools like control charts. The objective of this work is to study the effects of measurement uncertainty on control charts and to identify the situations in which its application exerts greater influence. A research was made, mapping of the articles published between 2004 and 2010 regarding measurement uncertainty, aiming to identify which calculation methods and approaches are most widely used. After, a method was developed to include uncertainty of the measurement system in control charts, modifying the probabilities of type I and type II errors. Finally, it was created a computer simulation using the method developed, to make it possible to analyze those situations in which the measurement uncertainty must be considered and which it can be neglected.
205

Construção e caracterização de um amplificador em fibra para pulsos ultracurtos em ʎ = 1.5 um

ARIAS, Luis Alfredo Giraldo 11 December 2014 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-07-26T14:41:01Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertacao luis giraldo.pdf: 10535616 bytes, checksum: 68be7b1f243dec018540fff871537861 (MD5) / Made available in DSpace on 2016-07-26T14:41:01Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertacao luis giraldo.pdf: 10535616 bytes, checksum: 68be7b1f243dec018540fff871537861 (MD5) Previous issue date: 2014-12-11 / Lasers de pulsos ultracurtos baseados em fibras ópticas como meio de ganho constituem fortes candidatos para substituir lasers de estado sólido mais tradicionais, tais como o laser de Ti:safira. Uma das razões é o custo direto e outra é a possibilidade de compactação de sistemas que ocupam muito espaço e consomem quantidades significativas de energia. Um dos problemas de lasers baseados em fibras ópticas é que a potência óptica média disponível é relativamente baixa, da ordem de poucas dezenas de mW. Em nosso laboratório o interesse é em fazer uso de lasers em fibra pulsados para aplicações em metrologia óptica e óptica quântica e, em ambos os casos, as potências requeridas são maiores, indicando a necessidade de desenvolver um amplificador óptico. O sistema deve ser capaz de amplificar pulsos que incialmente têm duração da ordem de centenas de femtosegundos, taxa de repetição de centenas de MHz e energias por pulso da ordem de 1 pJ. Estes parâmetros indicam que o sistema deve operar num regime de forte saturação. Nesta dissertação serão descritos a construção e caracterização um amplificador óptico que faz uso de uma fibra dopada com érbio como meio de ganho. Foram testadas várias combinações de comprimento de fibra de ganho, comprimento de fibra de entrada e de saída que permitiram controlar os efeitos dispersivos e não lineares de forma a obter os maiores ganhos possíveis, mas mantendo a duração temporal dos pulsos amplificados dentro de uma faixa aceitável para as aplicações de interesse do laboratório. Com isto obtivemos um amplificador com um ganho de aproximadamente x15, com potências de entrada da ordem de 10 mW, mantendo a duração de pulso de saída do sistema da mesma ordem daquela do pulso de entrada. Estas características são satisfatórias para as aplicações em que o sistema será utilizado. / Ultrashort pulse laser based optical fiber as the gain medium are strong candidates to replace more traditional lasers solid state lasers such as Ti: sapphire. One reason is the direct cost and the other is the possibility of compression systems that take up much space and consume significant amounts of energy. One of the problems of lasers based on optical fibers is that the average optical power available is relatively low, of the order of a few tens of mW. In our laboratory interest is the use in pulsed fiber lasers for applications in quantum optics and optical metrology and, in both cases, the required powers are higher, indicating a need to develop an optical amplifier. The system should be able initially to amplify pulses that have a duration on the order of hundreds of femtoseconds, repetition rate of hundreds of MHz and pulse energies on the order of 1 pJ. These parameters indicate that the system should operate in a regime of strong saturation. This dissertation will be described the construction and characterization of an optical amplifier which makes use of an erbium doped fiber as the gain medium. Various combinations of gain fiber length, fiber length input and output control enabled dispersive and nonlinear effects in order to obtain the highest possible gains while maintaining the temporal duration of the amplified pulses within an acceptable range were tested for the applications of interest for the laboratory. With this we obtained an amplifier with a gain of about x15, with the input powers of about 10 mW, while maintaining the pulse duration of the output of the same order as that of the input pulse system. These features are suitable for applications where the system is used.
206

Construção e caracterização de um amplificador em fibra para pulsos ultracurtos em ʎ = 1.5 um. /

GIRALDO ARIAS, Luis Alfredo 11 December 2014 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-07-26T15:07:25Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertacao luis giraldo.pdf: 10535616 bytes, checksum: 68be7b1f243dec018540fff871537861 (MD5) / Made available in DSpace on 2016-07-26T15:07:25Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) dissertacao luis giraldo.pdf: 10535616 bytes, checksum: 68be7b1f243dec018540fff871537861 (MD5) Previous issue date: 2014-12-11 / Lasers de pulsos ultracurtos baseados em fibras ópticas como meio de ganho constituem fortes candidatos para substituir lasers de estado sólido mais tradicionais, tais como o laser de Ti:safira. Uma das razões é o custo direto e outra é a possibilidade de compactação de sistemas que ocupam muito espaço e consomem quantidades significativas de energia. Um dos problemas de lasers baseados em fibras ópticas é que a potência óptica média disponível é relativamente baixa, da ordem de poucas dezenas de mW. Em nosso laboratório o interesse é em fazer uso de lasers em fibra pulsados para aplicações em metrologia óptica e óptica quântica e, em ambos os casos, as potências requeridas são maiores, indicando a necessidade de desenvolver um amplificador óptico. O sistema deve ser capaz de amplificar pulsos que incialmente têm duração da ordem de centenas de femtosegundos, taxa de repetição de centenas de MHz e energias por pulso da ordem de 1 pJ. Estes parâmetros indicam que o sistema deve operar num regime de forte saturação. Nesta dissertação serão descritos a construção e caracterização um amplificador óptico que faz uso de uma fibra dopada com érbio como meio de ganho. Foram testadas várias combinações de comprimento de fibra de ganho, comprimento de fibra de entrada e de saída que permitiram controlar os efeitos dispersivos e não lineares de forma a obter os maiores ganhos possíveis, mas mantendo a duração temporal dos pulsos amplificados dentro de uma faixa aceitável para as aplicações de interesse do laboratório. Com isto obtivemos um amplificador com um ganho de aproximadamente x15, com potências de entrada da ordem de 10 mW, mantendo a duração de pulso de saída do sistema da mesma ordem daquela do pulso de entrada. Estas características são satisfatórias para as aplicações em que o sistema será utilizado. / Ultrashort pulse laser based optical fiber as the gain medium are strong candidates to replace more traditional lasers solid state lasers such as Ti: sapphire. One reason is the direct cost and the other is the possibility of compression systems that take up much space and consume significant amounts of energy. One of the problems of lasers based on optical fibers is that the average optical power available is relatively low, of the order of a few tens of mW. In our laboratory interest is the use in pulsed fiber lasers for applications in quantum optics and optical metrology and, in both cases, the required powers are higher, indicating a need to develop an optical amplifier. The system should be able initially to amplify pulses that have a duration on the order of hundreds of femtoseconds, repetition rate of hundreds of MHz and pulse energies on the order of 1 pJ. These parameters indicate that the system should operate in a regime of strong saturation. This dissertation will be described the construction and characterization of an optical amplifier which makes use of an erbium doped fiber as the gain medium. Various combinations of gain fiber length, fiber length input and output control enabled dispersive and nonlinear effects in order to obtain the highest possible gains while maintaining the temporal duration of the amplified pulses within an acceptable range were tested for the applications of interest for the laboratory. With this we obtained an amplifier with a gain of about x15, with the input powers of about 10 mW, while maintaining the pulse duration of the output of the same order as that of the input pulse system. These features are suitable for applications where the system is used.
207

Sistema de laser de diodo de cavidade estendida para padrões de frequência / Extended cavity diode laser system for primary frequency standards

Jair De Martin Junior 10 May 2013 (has links)
Este trabalho tem como objetivo principal desenvolver uma nova fonte de laser de diodo compacta e robusta, além de um novo drive de controle para serem utilizados em padrões primário de tempo e frequência tipo chafariz de átomo de Césio e padrões compacto baseados em átomos frios. Um dos requisitos para utilização de laser de diodo em padrões primários de tempo e frequência é sua estabilidade em frequência e baixíssimo ruído espectral. Além disto, dada à aplicação embarcada, o laser deve ser extremamente robusto com relação às condições adversas: mecânicas, térmicas e elétricas. Tanto a parte optomecânica, quanto os controles eletrônicos do novo laser foram desenvolvidos neste trabalho. Vale salientar que tal sistema, em sua concepção, é de grande interesse para diversos outros tipos de aplicação, como espectroscopia de gases (LIDAR), referências em outras frequências e experimentos de física atômica e molecular, que possuem elevados níveis de exigência com relação a ruídos espectrais. / This work has as main objective to develop a new source of diode laser compact and robust, beyond a new drive control for use in primary of time and frequency standards type cesium atom fountain and compact standards-based cold atoms. One of the requirements for the use of diode laser in primary of time and frequency standards are their stability in frequency and are very low spectral noise. Furthermore, given the embedded application, the laser must be extremely robust with respect to adverse conditions: mechanical, thermal and electrical. Both opto-mechanical part, as the electronic controls of the new laser were developed in this work. It is noteworthy that such a system, in its conception, is of great interest to many other types of applications such as spectroscopy of gases (LIDAR), references in other frequencies and experiments of atomic and molecular physics, which have high levels of demand with respect to spectral noise.
208

Monitoração in vivo - análise de incertezas / In vivo monitoring analysis of uncertainties

Lucas Rodrigues dos Santos 10 April 2012 (has links)
Este trabalho teve como objetivos estabelecer os protocolos para o cálculo de incertezas de medição e a interpretação dos resultados de monitoração do Laboratório de Monitoração In Vivo (LMIV). Especificamente, o trabalho visou quantificar a contribuição dos fatores de influência para o cálculo de incertezas, e estabelecer a incerteza nas medidas. Foram utilizados dois detectores cintiladores de iodeto de sódio ativados com tálio (NaI:Tl) que possuem dimensões de 8x4\" (detector de corpo inteiro) e 3x3\" (detector de tireóide), um analisador multicanal EG&G Ortec, modelo 920E, e um microcomputador onde os espectros são adquiridos, analisados e armazenados com o auxílio do programa Renascence32, Ortec. As medições foram realizadas utilizando-se o objeto simulador antropomórfico do Alderson Research Labs. O radionuclídeo de interesse adotado para este estudo foi o 137Cs. Foram estudadas as influências dos fatores operador, geometria de medição, condições ambientais, flutuações eletrônicas com o tempo e baixa atividade. A análise das incertezas resultou em uma incerteza combinada relativa de 15,7% para o sistema 8x4\" e 9,8% para o sistema 3x3\". Estes valores foram obtidos seguindo os princípios recomendados no Guia para Expressão da Incerteza de Medição (GUM) da Joint Committee for Guides in Metrology (JCGM). / This work aimed to quantify the contribution of influence factors for the calculation of uncertainties and establish the uncertainties in the measurements of the In Vivo Monitoring Laboratory (LMIV). The materials used were used: two scintillator detectors of sodium iodine activated with thallium (NaI:Tl), with the dimension of 8x4\" (whole body detector) and 3x3\" (thyroid detector), an EG&G Ortec, model 920E multichannel analyzer and a microcomputer, where the spectra are acquired, analyzed and stored, with the support of Ortecs software, Renascence32. The measurements were carried out using the anthropomorphic simulating object from Alderson Research Labs. The targeted radionuclide adopted for this study was 137Cs. The influence factors were operator, measurement geometry, environmental conditions and Electronic fluctuations over time. The analysis of the uncertainties resulted in a relative combined uncertainty of 15.7% for the 8x4\" system and 9.8% for the 3x3\" system. These values were obtained following the Guide for Expression of Uncertainty in the Measurement, (GUM) of Joint Committee for Guides in Metrology (JCGM).
209

[en] STANDARDIZATION AND METROLOGICAL RELIABILITY OF CIGARETTE FIRMNESS RESULTS / [pt] PADRONIZAÇÃO E CONFIABILIDADE METROLÓGICA DOS RESULTADOS DE FIRMEZA DO CIGARRO

FRANCY GOERSCH NOGUEIRA 24 March 2006 (has links)
[pt] A qualidade de um cigarro pode ser avaliada por parâmetros físicoquímicos. A caracterização de muitos destes parâmetros é essencial para a definição dos índices utilizados por um fabricante de cigarros para acompanhamento do produto no mercado. A firmeza do cigarro é um dos parâmetros utilizados para definição desses índices, e avalia seu grau de rigidez, podendo ser definido, de uma maneira geral, como a relação entre o diâmetro final do cigarro, após a realização de um ensaio de compressão, e o diâmetro inicial. A Firmeza é função de três variáveis: deformação vertical do cigarro, produzida pela aplicação de uma força padronizada, valor especificado de umidade no fumo e circunferência média do cigarro. Com o objetivo de possibilitar a comparação entre os diversos produtos, a firmeza medida é corrigida para um valor de referência de umidade, previamente especificado, pela utilização de um modelo exponencial. Apesar deste modelo ter sido devidamente validado para os produtos Souza Cruz, e ter sido considerado aceitável para determinação da firmeza corrigida, não foram avaliadas as incertezas associadas à sua utilização. Neste trabalho, foram utilizados nos ensaios onze (11) tipos de cigarros e medida a firmeza conforme os procedimentos adotados pela empresa, previamente qualificados. O método dos mínimos quadrados foi utilizado para o desenvolvimento de modelos, juntamente com a estimativa das incertezas. Neste estudo foram avaliados também outros modelos, no sentido de se obter aquele que gerasse resultados com menores incertezas, bem como a avaliação dos parâmetros que contribuem para o aumento da incerteza de medição da firmeza corrigida. Foi concluído que as características do produto contribuem para a elevada incerteza associada, o que resulta em repetitividade não muito boa. Com base nestes resultados, sugere-se o estabelecimento de critérios de aceitação do produto, compatíveis com as incertezas associadas à medição, comparando-se com os valores de Firmeza normalmente aceitos e testados pelo mercado. / [en] Cigarette quality can be evaluated by physical and chemical parameters. Characterizing most of these parameters is essential to defining the indices cigarette manufacturers use while monitoring the product on the market. Cigarette firmness is one of the parameters used for defining these indices and evaluates cigarette degree of rigidity. Generally, it can be defined as the ratio of the final cigarette diameter, following a compression assay, to its initial diameter. Firmness is a function of three variables: cigarette upright deformation as produced by applying a standard load; specified tobacco moisture, and cigarette mean circumference. With a view to enabling comparison between several products, the measured firmness is corrected to a previously specified reference moisture value by having use of an exponential model. In spite of this model having been properly validated for Souza Cruz products and considered as acceptable for the determination of corrected firmness, the uncertainties associated with its use have not been evaluated. The trials described in this paper used eleven (11) types of cigarettes and the firmness was measured as per previously qualified procedures used by Souza Cruz. The method of minimum squares was used in the development of models jointly with uncertainty estimate. Also evaluated in this study were other models so as to achieve that which could generate results with lowest uncertainties and those parameters which contribute to increasing uncertainty of corrected firmness measurements. The conclusion was that product characteristics contribute to increasing the associated uncertainty which results in poor repeatability. On the basis of these results, it is suggested that product acceptance criteria be established that are compatible with measurement associated uncertainties by comparing these with firmness values usually accepted and tested by the market.
210

[en] STUDY OF THE METROLOGICAL RELIABILITY OF SPHYGMOMANOMETERS / [pt] ESTUDO DA CONFIABILIDADE METROLÓGICA DE ESFIGMOMANÔMETROS

SERGIO HENRIQUE SILVA JUNIOR 08 October 2008 (has links)
[pt] Observa-se um crescente interesse na determinação da incerteza de medição para a avaliação de conformidade e garantia da qualidade, principalmente nos setores de meio- ambiente, segurança, saúde e indústria, nos quais o resultado da medição é considerado crítico por lidar diretamente com seres humanos. Na medição da pressão arterial, conforme estudos realizados em países como a Austrália, Inglaterra, Turquia e Brasil, observa-se uma grande preocupação com a confiabilidade dos resultados obtidos por esfigmomanômetros mecânicos não invasivos. Nestes estudos, erros de até 4,4 kPa (33 mmHg) foram encontrados nos instrumentos avaliados, contra o valor de erro máximo de 0,53 kPa (4 mmHg) definido na OIML R 16-1:2002. Atualmente, a avaliação da confiabilidade dos esfigmomanômetros mecânicos é obtida considerando apenas o erro de medição, sem considerar a incerteza de medição. Com a motivação de contribuir para a garantia da confiabilidade metrológica dos esfigmomanômetros mecânicos não invasivos, usados mundialmente em hospitais e residências, o presente trabalho tem por objetivo associar a incerteza de medição na avaliação da confiabilidade metrológica destes instrumentos. Para a realização das medições foi montado um aparato envolvendo instrumentos de monitoração ambiental conforme recomendações internacionais (OIML R-16-1:2002) e nacionais (ABNT NBR-14105:1998 e NIEDIMEL- 006). Os dados do presente trabalho foram obtidos por meio de medições diretas em esfigmomanômetros novos e usados utilizando um padrão de pressão. Foram avaliados: o erro de medição, a histerese, o erro fiducial e a incerteza de medição. Os resultados obtidos com o presente trabalho mostram que, em função da incerteza de medição, o erro máximo permissível de 0,53 kPa (4 mmHg) pode não fornecer a confiabilidade adequada. Se for considerado apenas o erro de medição do manômetro conforme a OIML R 16- 1:2002, 60 % dos esfigmomanômetros avaliados foram aprovados. Se for considerado o erro e a incerteza de medição do manômetro, conforme proposto, apenas 12 % dos esfigmomanômetros foram aprovados. Com base nos resultados obtidos no presente trabalho, propõe-se reduzir o erro máximo admissível para estes instrumentos, incorporando a incerteza de medição, sem a necessidade de realizar na prática o seu cálculo. Com base nos resultados do presente trabalho recomenda-se uma revisão na faixa de erro máximo permissível na avaliação da OIML, em conjunto com a proposta de uma nova especificação do manômetro usado nos esfigmomanômetros, com redução do erro intrínseco e melhora de sua resolução. / [en] It is observed an increasing interest on the estimation of measurement uncertainty to deciding on conformity and quality assurance, mainly in the fields of environment, safety, health and industry, in which the measurement results are critical once they directly deal with human beings. According to studies performed in Australia, England, Turkey and Brazil, a great concern is observed with the reliability of the results obtained for blood pressure measurements by noninvasive mechanical sphygmomanometers. In these studies, errors of up to 4,4 kPa (33 mmHg) were obtained in the evaluated instruments, against the value of maximum error of 0,53 kPa (4 mmHg) required by OIML R 16-1:2002. Nowadays, the evaluation of the reliability of these measurement instruments for medical diagnosis is obtained considering only the measurement error (according to OIML R 16-1:2002), without taking into account the measurement uncertainty. Motivated to contribute for the metrological reliability of non- invasive mechanical sphygmomanometers, globally used in hospitals and residences, the present work aims at developing a model to associate the measurement uncertainty on the metrological reliability evaluation of these instruments. In order to perform the measurements with the sphygmomanometers, a set-up were prepared with environmental monitoring according to international recommendation (OIML R-16:2002) and national standards (ABNT NBR-14105:1998 and NIE-DMEL-006). The data of the present work were obtained by means of direct measurements in new and in use sphygmomanometers, utilizing a pressure pattern. Calculation of the following parameters was performed: measurement error, hysteresis, fiducial error and measurement uncertainty. The obtained results show that, as a function of the measurement uncertainty, the maximum permissible error of 0.53 kPa (4 mmHg) can be overcome. Considering the manometer measurement error, according to OIML R 16-1:2002, 60 % of the non- invasive mechanical sphygmomanometers evaluated were approved. When considering not only the measurement error, but also measurement uncertainty of the manometer, only 12% of the non-invasive mechanical sphygmomanometers were approved. Based on the present results, a reduction of the maximum permissible error for these instruments, incorporating the measurement uncertainty, without the need to calculate it in the verification procedure, is proposed. This work recommends not only a review of OIML maximum permissible error for sphygmomanometers, but also proposes a new configuration of the instrument, with reduction of intrinsic error and improvement of resolution.

Page generated in 0.0523 seconds