• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 134
  • 1
  • Tagged with
  • 137
  • 109
  • 91
  • 88
  • 73
  • 67
  • 54
  • 50
  • 49
  • 39
  • 36
  • 34
  • 32
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Desenvolvimento de métodos para coleta e determinação de poluentes em fase gasosa da atmosfera utilizando amostragem por difusão com membranas capilares microporosas / Development of methods for sampling and determination of gaseous pollutants in the atmosphere using diffusional microporous capillary membrane scrubber

Lúcia Helena Gomes Coelho 23 November 2009 (has links)
A tese enfatiza o desenvolvimento e aplicação de amostradores difusionais para pré-concentração de traços de poluentes gasosos e sua conjugação com técnicas de separação e determinação, especialmente, a eletroforese capilar. Foram implementadas novas aplicações para um amostrador com múltiplos filamentos microporosos de polipropileno, previamente desenvolvido pelo grupo de pesquisa, e para o novo dispositivo de coleta de dimensões reduzidas, composto por monofilamento microporoso de polipropileno (CMDS) com volume interno de 30 µL. Para o estabelecimento da vazão estável em 1,0 µL min-1 de fase aceptora pelo capilar poroso, recorreu-se à pressurização do reservatório com uma bomba pneumática de aquário e regulagem de vazão por um capilar de sílica fundida e uma válvula de agulha. Outra bomba pneumática foi utilizada para aspirar o fluxo de ar amostrado. As amostras foram coletadas seqüencialmente em frascos de 200 µL, mantidos sob temperatura reduzida em unidade de refrigeração do tipo Peltier acoplado ao amostrador. O CMDS monofilamentar, mais compacto e robusto, apresentou alta eficiência de coleta para a pré-concentração de formaldeído (CH2O), ácidos fórmico e acético e amônia da fase gasosa da atmosfera. Para as espécies com elevada constante de Henry, água deionizada serviu como fase aceptora, enquanto que para amônia, recorreu-se ao deslocamento do equilíbrio por um aceptor ácido, de modo a reter o analito na forma de NH4 +. A concentração das espécies em fase líquida foi determinada posteriormente por eletroforese capilar com detecção condutométrica sem contato (CE-C4D). Os limites de detecção, em fase líquida, para formiato, acetato, formaldeído (determinado na forma do aduto hidroximetanosulfonato HMS) e amônio foram estimados em 1,0, 1,5, 1,2 e 1,2 µmol L-1, respectivamente (equivalentes à 0,9, 3,0, 1,0 e 0,7 µg m-3 dessas espécies na atmosfera, respectivamente). Para a determinação de CH2O por injeção em fluxo (FIA) acoplada à detecção amperométrica em eletrodo de ouro platinizado, fez-se uso do coletor multifilamentar, por atender melhor à necessidade de volume de amostra. A interferência de espécies comumente presentes na atmosfera, como H2O2 e SO2, pôde ser contornada realizando coletas em presença de peróxido de hidrogênio para promover a oxidação do S(IV) à S(VI) e, posteriormente, destruindo o oxidante em reator contendo enzima catalase imobilizada. A determinação de CH2O foi implementada com sucesso por FIA com detecção por amperometria em eletrodo de ouro platinizado. Um CMDS portátil que funciona à pilha, próprio para amostragens em campo, foi desenvolvido utilizando, para o deslocamento do ar amostrado, uma bomba de pistão retirada de aparelho automático para medida de pressão arterial. O amostrador foi empregado na coleta de H2S, SO2 e alquil-mercaptanas em fase gasosa da atmosfera, utilizando fase aceptora alcalina para promover a desprotonação e conseqüente fixação das espécies em meio líquido. Os analitos foram determinados por CE-C4D ou por microextração em fase sólida (SPME) seguida de determinação por GC. O uso conjunto do antioxidante ascorbato para conservação das amostras e de etanol para fixação dos compostos voláteis em meio aquoso permitiu o estabelecimento de um protocolo completo para coleta e detecção dessas espécies reduzidas de enxofre, com sensibilidade suficiente para monitorar emissões de origem biogênica, o que foi exemplificado na prática coletando amostras próximo a um córrego contaminado com esgoto. A perfeita combinação do diminuto volume de fase aceptora do CMDS com a demanda de nanolitros de amostra da CE-C4D culminou com o desenvolvimento de um sistema de análise total (TAS) com gerenciamento de fluidos baseado em propulsão por bombas de aquário (de baixo custo e alta durabilidade) e válvulas solenóide de estrangulamento, controladas por computador. Como exemplo de aplicação inovador e bem sucedido do TAS desenvolveu-se a análise concomitante e em tempo quase real de ácidos fórmico e acético no ar, com freqüência de 10 pares de dados por hora. As vantagens do sistema CMDS-CE-C4D incluem simplicidade, versatilidade, consumo de reagentes e amostra e geração de resíduos minimizada, robustez e rapidez enquanto uma amostra é coletada, o eletroferograma da anterior é adquirido sem necessidade de bombas de alta pressão ou colunas dispendiosas como as requeridas para HPLC / The development and application of porous membrane diffusion samplers for fast and efficient pre-concentration of an array of trace air pollutants was emphasized in this thesis, in conjunction with compatible separation and determination techniques, especially capillary electrophoresis. New applications were found for a formerly developed diffusion scrubber based on a bundle of microporous hollow polypropylene capillary membranes and for a scaled down version with a single core capillary membrane diffusion scrubber (CMDS) comprising an internal volume of 30 µL, were used for sampling of the trace level pollutants to an adequate liquid acceptor. The low-flow of acceptor solution, 1.0 µL min-1, required by the CMDS was satisfied by pressurization of the reservoir with an aquarium pump combined with flow regulation by a silica capillary as hydrodynamic resistor and a needle valve. Another aquarium pump was used for the aspiration of the sampled air through the sampler. The low volumes collected in the CMDS were stored in 200 µL vials inserted in a cooling plate of a Peltier device. The robust and compact system was used for sampling of formaldehyde (CH2O), formic acid, acetic acid and ammonia in the gaseous phase of the atmosphere. For chemical species with high Henry´s constant, deionized water suffices as acceptor phase. Otherwise, equilibria displacement to a non-volatile ion, like NH4 + for NH3 sampling, promoted quantitative retention in the acceptor phase. The concentrations of the analytes in the liquid phase were determined by capillary electrophoresis with capacitively coupled contactless conductometric detection (CEC4D). The detection limits obtained in the liquid phase for formate, acetate, formaldehyde (in the form of the adduct hydroxymethanesulfonate HMS) and ammonium were 1,0, 1,5, 1,2 e 1,2 µmol L-1 respectively (what corresponds to 0,9, 3,0, 1,0 e 0,7 µg m-3 of the respective gaseous species in the air). The higher volume of acceptor phase provided by the sampler with a bundle of microporous membrane capillaries (~600 µL) are in tune with the needs of flow injection analysis (FIA), as demonstrated for amperometric detection of CH2O on a platinized gold electrode. The interferences from SO2 and H2O2 were overcome by adding H2O2 to the acceptor solution to promote the oxidation of S(IV) to S(VI) and destruction of the oxidant afterwards in a column with immobilized catalase enzyme. The aquarium pump used for gas aspiration was substituted to a piston pump, taken from arterial blood pressure meter fed with 8 V D.C., to turn possible field collections with the CMDS device. The system was used for the sampling of H2S, SO2 e alkyl-mercaptans in the gaseous phase of the atmosphere. To succeed on that, the samplings were performed in alkaline media to promote deprotonation of the species (and stabilization in non-volatile forms). The collected analytes were determined by CE-C4D or by solid phase microextraction (SPME) followed by GC analysis. The joint use of the antioxidant ascorbate for sample preservation and ethanol for fixation of the volatile compounds allowed the establishment of a complete protocol for sampling, storage and detection of the sulfur reduced species with enough sensitivity for monitoring biogenic emissions from waste discharge. Perfect matching of the low-volume characteristics of the CMDS device and the CE-C4D equipment led to the conception of a low-cost automatic CMDS-CE-C4D total analysis system (TAS) and its innovative and successful application to near-realtime simultaneous analysis of formic acid and acetic acid in air. During the evaluation of one sample, the TAS collects a new one, with valves, pumps and high voltage delivery under software control. Advantages include rapidity (10 data points per hour for each analyte), high preconcentration efficiency, simplicity and versatility, minimum sample and reagent consumption and residue generation (green analytical method), no need of costly high pressure pumps and separation columns like those used in HPLC
132

Redistribuição postmortem de antidepressivos e seus produtos de biotransformação em tecidos biológicos humanos / Postmortem redistribution of antidepressants and their metabolites in human biological tissues.

Marcelo Filonzi dos Santos 10 December 2014 (has links)
Os antidepressivos pertencem a uma importante classe de medicamentos investigados na toxicologia forense. Em casos de amostras provenientes de cadáveres, o intervalo entre o óbito e a obtenção da espécie biológica pode proporcionar a redistribuição postmortem destes fármacos. Com o objetivo de elucidar esse fenômeno, métodos analíticos foram desenvolvidos e aplicados utilizando sangue total (ST), humor vítreo (HV) e fígado. Para as amostras de ST e HV, o método de extração escolhido e validado foi a microextração em fase líquida (LPME) trifásica. Fibras ocas constituídas de polipropileno, com a extensão de 8 cm cada, foram tratadas com o solvente orgânico dodecano (fase orgânica), resultando em um membrana com permeabilidade seletiva. No lúmen destas fibras, adicionou-se ácido fórmico 0,1 mol/L (fase aceptora). Em frasco de fundo chato com 5 mL de capacidade, pipetou-se 3,5 mL de NaOH 0,1 mol/L (fase doadora) e 0,5 mL de ST ou HV. Ao término da extração, as amostras foram introduzidas no GC-MS, sem a necessidade de reações de derivatização. O estudo com ST contemplou os antidepressivos amitriptilina (AMI), nortriptilina (NTR), imipramina (IMI), desipramine (DES), clomipramina (CLO), desmetilclomipramina (DMC), fluoxetina (FLU) e norfluoxetina (NFL). Os limites de quantificação para estas substâncias ficaram inferiores aos níveis terapêuticos (20 ng/mL). As médias dos coeficientes de variação intradia e interdia foram, respectivamente, de 9,7 e 9,8%. As curvas de calibração apresentaram linearidade entre as concentrações de 20 até 1200 ng/mL. A validação do parâmetro integridade da diluição assegurou a mensuração de quantidades superiores ao limite apresentado na curva de calibração. O método foi aplicado em sete amostras reais postmortem e em apenas um caso foi observada uma diferença significativa (300%) entre os valores quantificados no ST periférico e central. Os antidepressivos tricíclicos AMI, NTR, IMI e DES foram avaliados no HV e o efeito matriz foi detectado para os dois últimos analitos. O método foi otimizado e validado utilizando solução salina adicionada de AMI e NTR. O limite de detecção igual a 5 ng/mL, foi obtido com a redução da voltagem da fonte de íons do espectrômetro de massa para 50 eV. Coeficientes de variação foram inferiores a 15%. Os procedimentos validados foram aplicados em seis amostras reais de HV. A relação encontrada entre os valores obtidos no ST periférico e HV foi de aproximadamente 0,1. A extração acelerada por solvente (ASE) e, posteriormente, a extração em fase sólida (SPE) foram as técnicas de separação dos analitos da matriz fígado. Ao término das citadas extrações, os antidepressivos foram analisados no GC-MS. Para esta matriz sólida, são necessários mais estudos, pois os valores encontrados nos ensaios analíticos estão em desacordo com as diretrizes utilizadas na validação dos métodos. / Antidepressants belong to an important class of drugs investigated in forensic toxicology. In cases of samples from corpses, the interval between death and obtaining the biological specimens can provide the postmortem redistribution of these drugs. Aiming to elucidate this phenomenon, analytical methods were developed and applied using whole blood (WB), vitreous humor (VH) and liver. For samples of WB and HV, the extraction method chosen and validated was the three-phase liquid phase microextraction (LPME). Hollow fibers consist of polypropylene, with a length of 8 cm each were treated with dodecane organic solvent (organic phase) resulting in a membrane with selective permeability. Into the lumen of these fibers was added formic acid 0.1 mol/ L (acceptor phase). In the vial containing 3.5 mL of NaOH 0.1 mol / L (donor phase) was spiked 0.5 ml of biological fluids (WB or VH). Subsequently, the samples were injected in GC-MS without derivatization reactions. The study of the ST included antidepressants amitriptyline (AMI), nortriptyline (NTR), imipramine (IMI), desipramine (DES), clomipramine (CLO), desmethylclomipramine (DMC), fluoxetine (FLU) and norfluoxetine (NFL). The quantification limits for these substances were below the therapeutic levels (20 ng / ml). The mean coefficients of variation and separate intradays were respectively 9.7 and 9.8%. The calibration curves showed linearity between concentrations of 20 to 1200 ng / mL. The validation of the integrity of the dilution parameter assured measurement higher than the limit shown in the calibration curve quantities. The method was applied to seven real postmortem samples and in one case a significant difference (300%) between the measured values in the peripheral and central ST was observed. The tricyclic antidepressants AMI, NTR, IMI and DES were evaluated in VH and the matrix effect was detected in the last two analytes. The method was optimized and validated using saline spiked AMI and NTR. The limit of detection (5 ng/ml) was obtained by reducing the voltage of the ion source of the mass spectrometer 50 eV. Coefficients of variation were below 15%. The procedures were validated in six real samples of HV. The relationship found between the values obtained in the peripheral ST and HV was approximately 0.1. Accelerated solvent extraction (ASE) and subsequently the solid phase extraction (SPE) were the techniques of separation of analytes liver matrix. At the end of the cited extractions, antidepressants were analyzed in GC-MS. To this solid tissue, further studies are needed, because the values found in the analytical tests were not in accordance with the guidelines used in the validation of the methods.
133

Eletrofiação de nanofibras de fibroína da seda como dispositivos adsorventes para microextração em fase sólida / Silk fibroin nanofibers electrospun as adsorbents device for solid phase microextraction

Muller, Vinicius 04 July 2014 (has links)
Made available in DSpace on 2017-07-10T18:08:02Z (GMT). No. of bitstreams: 1 Vinicius Muller.pdf: 5054743 bytes, checksum: 4684dd9325f819006bfd84424d666674 (MD5) Previous issue date: 2014-07-04 / Electrospinning technique was applied in the covering of fused silica fibers by regenerated silk fibroin nanofibers (RSF). The parameters of electrospinning process were evaluated through factorial experimental design 22. This study showed the variables flow of solution and capillary-collector distance were statistically significant in the medium diameter response. The model obtained was validated through variance analysis (ANOVA) and response surface methodology. The material was used at solid phase micro extraction (SPME) in the extraction of samples containing a small chain alcohol, applied at gas chromatography (GC). The recovered device was characterized through Fourier transform infrared spectroscopy with attenuated total reflectance (FTIR-ATR) and thermal analysis (DSC and TGA). The RSF nanofibers covered fibers were morphologic evaluated through scanning electronic spectroscopy (MEV). The results of MEV showed that was possible to obtain fibers in nanoscale, medium diameter around 304 ± 46 nm. The fibers were also submitted to simulated thermal treatment (100°C to 250°C). There was no fusion between the fibers until 250°C (4 hours of treatment), and a little structural damage. The thermal analysis of FRS and covered FRS nanofibers device showed that the electrospun material maintained the thermal stability, with loss due thermal degradation from 250°C. The GC assay demonstrated the standard SPME covered device didn´t interfere on the suggested method to the alcohol isopropyl analysis (AIS). The times of extraction and desorption were optimized in 20 minutes and 10 minutes, respectively. The methodology was evaluated about linearity and specificity. In the concentration between 10 to 500 ppm of AIS, the method was linear, with R2= 0,9927 and selective, with high resolution between peaks of methanol, AIS and ethyl acetate. Electrospinning process of RSF as covering device showed great potential to use in SPME due its high surface area, thermal stability and easiness process, as well as potential to application in extraction of alcohols and GC analysis. / A técnica de eletrofiação foi aplicada no revestimento de fibras de sílica fundida por nanofibras de fibroína de seda regenerada (FSR). Os parâmetros do processo de eletrofiação foram avaliados por meio de delineamento experimental fatorial 2². Este estudo mostrou que as variáveis vazão da solução e distância entre capilar-coletor foram estatisticamente significativas na resposta diâmetro médio. O modelo obtido foi validado através da análise de variância (ANOVA) e metodologia de superfície de resposta. O material foi empregado em Microextração em Fase Sólida (Solid Phase Microextraction SPME ) na extração de amostras contendo um álcool de cadeia pequena, aplicado em cromatografia gasosa (CG). O dispositivo recoberto foi caracterizado por meio de espectroscopia na região do infravermelho (FTIR-ATR) e análises térmicas (DSC e TGA). As fibras recobertas com nanofibras de FSR foram avaliadas morfologicamente através de microscopia eletrônica de varredura (MEV). Por meio dos resultados das análises de MEV, observou-se que foi possível obter fibras em escala nanométrica, com diâmetro médio em torno de 304 ± 46 nm. As fibras também foram submetidas a tratamento térmico em forno (100°C a 250°C). Não houve fusão das fibras até 250°C (até 4 h de tratamento), e poucos danos estruturais. As análises térmicas da FSR e do dispositivo recoberto com as nanofibras de FSR mostraram que o material eletrofiado manteve a estabilidade térmica, com perda por degradação térmica a partir de 250 °C. Os ensaios em CG demonstraram que o branco com o dispositivo de SPME recoberto não interferiu no método proposto para a análise de álcool isopropílico (AIS). Os tempos de extração e dessorção do analito foram otimizados em 20 min e 10 min, respectivamente. A metodologia foi avaliada quanto à linearidade e especificidade. Na faixa de concentração de 10 a 500 ppm de AIS, o método foi linear, com R=0,9927 e seletivo, apresentando alta resolução entre os picos de metanol, AIS e acetato de etila. O processo de eletrofiação da FSR como recobrimento do dispositivo mostrou grande potencial para emprego em SPME devido a sua grande área superficial, estabilidade térmica e facilidade no processo, bem como potencial para aplicação em extração de alcoóis e análise em CG.
134

Desenvolvimento de suportes vítreos e vitrocerâmicos baseados no sistema Li2O-BaO-SiO2 mofificados pelos óxidos Nb2O5, TiO2, V2O5 e ZrO2, para microextração em fase sólida (SPME-CG) / Development of new glass and glass-ceramics supports for solid phase microextraction (SPME-CG)

Percio, Maycon Fernando 28 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:08:21Z (GMT). No. of bitstreams: 1 Maycon Fernando Percio.pdf: 4386871 bytes, checksum: fd68bea53c4d4cbfe32a314a01715c6e (MD5) Previous issue date: 2012-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In the present work a vitreous composition based on combination of the oxides BaO-SiO2-Li2O modified by adding of oxides Nb2O5, TiO2, V2O5 and ZrO2 as nucleating agent was evaluated and used in the manufacture of glass and glass-ceramic fibers for use in SPME-CG. The stability of the resulting glasses was accompained by X-ray diffraction (XRD) and differential thermal analysis (DTA). The stability parameters of Weinberg (KW), Hubrÿ (KH), Lu e Liu (KLL), Du and Huang (KDU) and Saad and Poulain (KSP) were obtained by DTA data. By KSP was observed that stability of glassy phases follows the descending order: Composition 5 (ZrO2) > Composition 2 (Nb2O5) > Composition 1 (without nucleant) > Composition 4 (V2O5) > Composition 3 (TiO2). Through these data it was possible to determine the apparent activation energies of the crystallization process by the crystallization peaks of the DTA curves, whereby the decreasing order was obtained: Composition 5 (ZrO2)> Composition 4 (V2O5) > Composition 2 (Nb2O5) > Composition 3 (TiO2) > Composition 1 (without nucleant). It was found, through the Avrami index, a surface crystallization mechanism of the compositions that leads to a correspondent transition to the glass ceramic. From DRX data obtained after thermal treatment at varying time, the TTT diagrams (Time, Temperature and Transformation) of the compositions were constructed, which delimited the conditions for preparation of glass ceramic fibers. The XRD analysis indicated that the main crystalline phases formed after heat treatments are rhombic Li2SiO3 Li2Si2O5. The fibers obtained were further tested in chromatographic analysis by HS-SPME-GC of the methanol in aqueous solution at concentrations of 10 and 100 mgL-1 with satisfactory results. / No presente trabalho, foram estudadas composições vítreas baseada na combinação dos óxidos Li2O-BaO-SiO2 modificadas pelos óxidos Nb2O5, TiO2, V2O5 e ZrO2, utilizados como nucleantes na fabricação de fibras de vidro e vitrocerâmicas para a utilização em SPME-CG. Determinou-se a estabilidade vítrea para cada composição através da difração de raio-X (DRX) e análise térmica diferencial (DTA) sendo observada a estabilidade das fases vítreas na ordem decrescente: Composição 5 (ZrO2) > Composição 2 (Nb2O5) > Composição 1 (sem nucleante) > Composição 4 (V2O5) > Composição 3 (TiO2). Através destes dados foi possível determinar as energias de ativação aparente das fases cristalinas através dos picos de cristalização das curvas de DTA, cuja ordem decrescente obtida foi: Composição 5 (ZrO2) > Composição 4 (V2O5) > Composição 2 (Nb2O5) > Composição 3 (TiO2) > Composição 1 (sem nucleante). Verificou-se através do índice de Avrami que as composições vítreas obtidas apresentaram mecanismo de nucleação de superfície para a formação do vitrocerâmico. Os dados de DTA possibilitaram a obtenção de diagramas de Tempo, Temperatura e Transformação (TTT), que delimitaram as condições de preparo das fibras vitrocerâmicas. Foram fabricados 5 tipos diferentes de fibras vítreas (Fibras A), que após tratamento térmico deram origem a fibras vitrocêramicas parcialmente cristalizadas (Fibras B) e fibras vitrocerâmicas totalmente cristalizadas (Fibras C), resultando um total de 15 espécies de fibras de composições e estruturas cristalinas diferentes. As análises por DRX indicaram que as principais fases cristalinas formadas depois dos tratamentos térmicos são Li2SiO3 e Li2Si2O5 ortorrômbicos. As fibras obtidas foram ainda testadas em análises cromatográficas por Cromatografia Gasosa na extração de metanol em solução aquosa nas concentrações de 10 e 100 mgL-1 com resultados satisfatórios.
135

Desenvolvimento e aplicação de método analítico para determinação de ésteres etílicos de ácidos graxos (bioindicadores do etanol) em amostras de mecônio / Development and application of an analytical method for the determination of fatty acid ethyl esters (biomarkers of ethanol) in meconium samples

Roehsig, Marli 28 August 2009 (has links)
O álcool é uma das substâncias psicoativas mais consumidas mundialmente e seu uso por mulheres em idade reprodutiva, em particular, tem representado grande preocupação por parte de especialistas e da sociedade em geral. Apesar dos efeitos adversos associados ao ato de ingerir bebidas alcoólicas durante a gestação ser bastante documentados e conhecidos, sabe-se que uma parcela de mulheres grávidas tem dificuldades em abandonar o hábito. O consumo excessivo de álcool durante a gravidez tem sido associado com a síndrome fetal pelo álcool (FAS), caracterizada por crianças com dificuldades comportamentais e de aprendizado. Entretanto, devido ao sentimento de culpa e medo de ações punitivas, mulheres raramente admitem terem utilizado álcool durante a gestação. Como resultado, uma série de marcadores biológicos tem sido estudada para se diagnosticar a exposição fetal ao etanol. Dentre os marcadores utilizados estão os ésteres etílicos de ácidos graxos (FAEE), que podem ser detectados em amostras de mecônio de recém-nascidos. No presente trabalho, um método analítico foi desenvolvido visando a detecção de oito FAEEs em amostras de mecônio e aplicada em amostras coletadas de recém-nascidos cujas mães admitiram ou não o uso de etanol durante a gestação. A microextração em fase sólida por Headspace (HS-SPME), uma técnica de preparação de amostras relativamente recente, foi utilizada para análise. Os FAEEs foram identificados e quantificados por cromatografia gasosa/espectrometria de massas (GC/MS), operado no modo de ionização química. Os correspondentes ésteres etílicos deuterados foram sintetizados e utilizados como padrão interno. Os limites de quantificação (LOQ) obtidos foram abaixo de 150 ng/g e limites de detecção (LOD) foram abaixo de 100ng/g para todos os analitos. O método mostrou boa linearidade na concentração estudada (LOQ-2000ng/g), com coeficiente (r2) melhor que 0.98. Os valores de precisão apresentaram coeficientes de variação menores que 15% para todos os FAEEs estudados. Quando o método foi aplicado em amostras de mecônio, foi possível detectar níveis de alguns FAEEs de recém-nascidos não suspeitos a exposição fetal ao etanol. / Alcohol is the main psychoactive drug consumed worldwide and its increasing use by young women has been a great problem point out by specialists in the subject. Although the adverse effects associated to the habit of drinking alcoholic beverages during gestation being very much documented, it is known that a considerable number of pregnant women have difficulties to abandon the habit. Excessive alcohol use during pregnancy has been associated with Fetal Alcohol Syndrome (FAS) characterized by children with cognitive and behavioral disorders. However, because of denial, embarrassment and fear, maternal reports of gestational use of alcohol are often inaccurate. Consequently, a series of biomarkers have been studied to diagnose fetal exposure to alcohol. Recently, fatty acid ethyl esters (FAEE) have been studied as biomarkers found in meconium of neonates exposed in utero. In the present work, an analytical method was developed aiming the detection of eight FAEEs in meconium samples and applied to real specimens collected from newborns whose mothers admitted or not the use of alcohol during pregnancy. Headspace solid-phase microextraction (HS-SPME), a relatively recent sample preparation technique, was used for analysis. FAEEs were identified and quantified by gas chromatography/mass spectrometry (GC/MS), operated in chemical ionization mode. The corresponding deuterated ethyl esters were synthesized and used as internal standards. The lower limits of quantification (LOQ) obtained were below 150ng/g and limits of detection (LOD) were bellow 100ng/g for all analytes. The method showed good linearity in the range of concentration studied (LOQ-2000ng/g), with coefficient of linearity better than 0.98. The precision assay, given by the relative standard deviation (RSD) of the method was lower than 15% for all FAEEs studied. When the method was applied to real samples, it was possible to detect trace levels of some FAEEs from non-suspected ethanol exposed newborns.
136

Desenvolvimento e aplicação de método analítico para determinação de ésteres etílicos de ácidos graxos (bioindicadores do etanol) em amostras de mecônio / Development and application of an analytical method for the determination of fatty acid ethyl esters (biomarkers of ethanol) in meconium samples

Marli Roehsig 28 August 2009 (has links)
O álcool é uma das substâncias psicoativas mais consumidas mundialmente e seu uso por mulheres em idade reprodutiva, em particular, tem representado grande preocupação por parte de especialistas e da sociedade em geral. Apesar dos efeitos adversos associados ao ato de ingerir bebidas alcoólicas durante a gestação ser bastante documentados e conhecidos, sabe-se que uma parcela de mulheres grávidas tem dificuldades em abandonar o hábito. O consumo excessivo de álcool durante a gravidez tem sido associado com a síndrome fetal pelo álcool (FAS), caracterizada por crianças com dificuldades comportamentais e de aprendizado. Entretanto, devido ao sentimento de culpa e medo de ações punitivas, mulheres raramente admitem terem utilizado álcool durante a gestação. Como resultado, uma série de marcadores biológicos tem sido estudada para se diagnosticar a exposição fetal ao etanol. Dentre os marcadores utilizados estão os ésteres etílicos de ácidos graxos (FAEE), que podem ser detectados em amostras de mecônio de recém-nascidos. No presente trabalho, um método analítico foi desenvolvido visando a detecção de oito FAEEs em amostras de mecônio e aplicada em amostras coletadas de recém-nascidos cujas mães admitiram ou não o uso de etanol durante a gestação. A microextração em fase sólida por Headspace (HS-SPME), uma técnica de preparação de amostras relativamente recente, foi utilizada para análise. Os FAEEs foram identificados e quantificados por cromatografia gasosa/espectrometria de massas (GC/MS), operado no modo de ionização química. Os correspondentes ésteres etílicos deuterados foram sintetizados e utilizados como padrão interno. Os limites de quantificação (LOQ) obtidos foram abaixo de 150 ng/g e limites de detecção (LOD) foram abaixo de 100ng/g para todos os analitos. O método mostrou boa linearidade na concentração estudada (LOQ-2000ng/g), com coeficiente (r2) melhor que 0.98. Os valores de precisão apresentaram coeficientes de variação menores que 15% para todos os FAEEs estudados. Quando o método foi aplicado em amostras de mecônio, foi possível detectar níveis de alguns FAEEs de recém-nascidos não suspeitos a exposição fetal ao etanol. / Alcohol is the main psychoactive drug consumed worldwide and its increasing use by young women has been a great problem point out by specialists in the subject. Although the adverse effects associated to the habit of drinking alcoholic beverages during gestation being very much documented, it is known that a considerable number of pregnant women have difficulties to abandon the habit. Excessive alcohol use during pregnancy has been associated with Fetal Alcohol Syndrome (FAS) characterized by children with cognitive and behavioral disorders. However, because of denial, embarrassment and fear, maternal reports of gestational use of alcohol are often inaccurate. Consequently, a series of biomarkers have been studied to diagnose fetal exposure to alcohol. Recently, fatty acid ethyl esters (FAEE) have been studied as biomarkers found in meconium of neonates exposed in utero. In the present work, an analytical method was developed aiming the detection of eight FAEEs in meconium samples and applied to real specimens collected from newborns whose mothers admitted or not the use of alcohol during pregnancy. Headspace solid-phase microextraction (HS-SPME), a relatively recent sample preparation technique, was used for analysis. FAEEs were identified and quantified by gas chromatography/mass spectrometry (GC/MS), operated in chemical ionization mode. The corresponding deuterated ethyl esters were synthesized and used as internal standards. The lower limits of quantification (LOQ) obtained were below 150ng/g and limits of detection (LOD) were bellow 100ng/g for all analytes. The method showed good linearity in the range of concentration studied (LOQ-2000ng/g), with coefficient of linearity better than 0.98. The precision assay, given by the relative standard deviation (RSD) of the method was lower than 15% for all FAEEs studied. When the method was applied to real samples, it was possible to detect trace levels of some FAEEs from non-suspected ethanol exposed newborns.
137

Desenvolvimento de métodos quantitativos e sistema de screening para a determinação de tetraciclinas em medicamentos veterinários e alimentos de origem animal usando procedimentos de análise por injeção em fluxo / Development of quantitative methods and screening system for the determination of tetracyclines in veterinary pharmaceuticals and animal-derived food using flow injection analysis procedures / Desarrollo de métodos cuantitativos y sistema de screening para la determinación de tetraciclinas en medicamentos veterinarios y alimentos de origen animal utilizando procedimientos de análisis por injección en flujo

Pérez Rodríguez, Michael [UNESP] 26 August 2016 (has links)
Submitted by MICHAEL PÉREZ RODRÍGUEZ null (michaelpr@iq.unesp.br) on 2016-09-16T20:43:06Z No. of bitstreams: 1 TESE MICHAEL VERSÃO FINAL.pdf: 4495815 bytes, checksum: 5d4a4f8ffcd143bb08ad336b289fe7ab (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-09-22T14:44:30Z (GMT) No. of bitstreams: 1 perezrodriguez_m_dr_araiq_par.pdf: 1340231 bytes, checksum: 9e639833f42ff1e6fc87e7f9f965f8fc (MD5) / Made available in DSpace on 2016-09-22T14:44:30Z (GMT). No. of bitstreams: 1 perezrodriguez_m_dr_araiq_par.pdf: 1340231 bytes, checksum: 9e639833f42ff1e6fc87e7f9f965f8fc (MD5) Previous issue date: 2016-08-26 / Pró-Reitoria de Pós-Graduação (PROPG UNESP) / Este trabalho descreve o desenvolvimento de métodos analíticos ambientalmente mais amigáveis utilizando sistemas de screening e procedimentos de análise por injeção em fluxo para a detecção e quantificação de antibióticos, da classe das tetraciclinas, em amostras de medicamentos veterinários e alimentos de origem animal como leite bovino e suplementos de ovos. Os métodos desenvolvidos foram baseados na reação de acoplamento diazo obtida entre as tetraciclinas e o ácido p-sulfanílico diazotado em meio básico, resultando na formação de azo compostos com máximos de absorção em torno de 435 nm, permitindo determinar esses antibióticos por espectrofotometria. As condições analíticas foram otimizadas através de análise multivariada utilizando planejamentos experimentais fatoriais e o desempenho dos métodos propostos foi avaliado através de parâmetros como linearidade, efeito matriz, precisão, exatidão, limite de detecção, limite de quantificação, recuperação e estudo de interferências. O primeiro trabalho desenvolvido fez uso de um procedimento de injeção em fluxo contínuo para a rápida determinação de tetraciclinas em formulações veterinárias comerciais, visando maior eficiência no controle de qualidade na indústria farmacêutica. Na sequência, foi desenvolvido um método de screening mediante análise por injeção em fluxo empregando uma cela capilar de longo caminho óptico (LWCC) para a detecção de resíduos de tetraciclinas em amostras de leite bovino, sem a necessidade de passos de extração dispendiosos e demorados ou complicados tratamentos de amostras. Finalmente, um novo método de microextração líquido-líquido dispersiva assistida por ultrassom (US-DLLME) foi desenvolvido para a simples, rápida e eficiente extração de resíduos de tetraciclinas a partir de amostras de suplemento de ovos e, posterior análise por injeção em fluxo baseada em uma cela capilar de longo caminho óptico (LWCC), empregando um banho de aquecimento com controle de temperatura. Os métodos descritos apresentaram importantes características como simplicidade operacional, possibilidade de automação, rapidez e baixo custo das análises. Além disso, estes métodos seguiram os princípios da química verde, de modo que permitiram realizar determinações ambientalmente mais limpas, através da redução considerável do consumo de reagentes e amostras, evitando ou minimizando o emprego de solventes tóxicos. Também, os métodos desenvolvidos para a análise de resíduos mostraram excelente desempenho para aplicação no controle de qualidade dos produtos alimentares estudados na indústria alimentícia, a fim de proteger os consumidores. / This work describes the development of environmentally friendly analytical methods using screening systems and flow injection procedures for detection and quantification of tetracycline antibiotics in veterinary pharmaceuticals and animal-derived foods such as bovine milk and egg-based protein supplements. The developed methods were based on the diazo coupling reaction between the tetracyclines and diazotized p-sulfanilic acid in basic medium, resulting in the formation of azo compounds that present maximum absorption around 435 nm, which allows determining these antibiotics by spectrophotometry. The analytical conditions were optimized by means of multivariate analysis using factorial experimental designs. Performance of the proposed methods was assessed through parameters such as linearity, selectivity, precision, accuracy, detection limit, quantification limit, matrix effect and recovery. The first developed work used a continuous flow injection procedure for the rapid determination of tetracyclines in commercial veterinary formulations, aiming greater efficiency in quality control in the pharmaceutical industry. Thereafter, it was developed a screening method by flow injection analysis using a liquid waveguide capillary cell (LWCC) for detecting tetracyclines residues in bovine milk samples, without the need for expensive extraction steps that are time-consuming or complicated sample treatments. Finally, a new ultrasound-assisted dispersive liquid-liquid microextraction (US-DLLME) method was developed for simple, rapid, and efficient extraction of tetracyclines residues from egg supplement samples, followed by flow injection analysis based on a liquid waveguide capillary cell (LWCC), using a controlled temperature heating bath. The described methods presented important features such as operational simplicity, possibility of automation, quickness and low cost of the analysis. Furthermore, these methods followed the principles of green chemistry, making possible to perform environmentally cleaner determinations, due to the considerable reduction of reagents and samples consumption, avoiding or minimizing the use of toxic solvents. Besides, the methods developed for residues analysis showed excellent performance for application in the food industry for quality control of the studied food products in order to protect consumers.

Page generated in 0.074 seconds