Spelling suggestions: "subject:"microtração"" "subject:"microextraction""
91 |
Determinação de canabinóides em cabelo por microextração em fase sólida por Headspace e análise por espectrometria de massa associada à cromatografia em fase gasosa / Determination of cannabinoids in hair by Headspace solid-phase microextraction and gas chromatography-mass spectrometryCarolina Dizioli Rodrigues de Oliveira 21 July 2005 (has links)
Foi desenvolvido um método para determinar canabinóides (canabidiol, canabinol e delta-9-tetraidrocanabinol) no cabelo. Uma amostra de 10mg foi descontaminada com diclorometano, seguida de digestão alcalina, microextração em fase sólida por headspace (HS-SPME) e analisada por espectrometria de massa associada à cromatografia em fase gasosa (GC/MS). Os limites de detecção e de quantificação foram de 0,07 e 0,12 ng/mg, respectivamente, para todos canabinóides estudados. O método demonstrou ser simples, rápido, preciso e linear no intervalo de 0,12 a 12 ng/mg (r2 > 0,98). Amostras de cabelo de 8 usuários de Cannabis foram coletadas de pacientes provenientes de uma clínica dependentes pela equipe médica. O método mostrou-se eficiente em amostras de cabelos de usuários que faziam uso da droga pelo menos 10 vezes por semana. / A method was to develop to detect cannabinoids (cannabidiol, cannabinol and delta-9-tetrahydrocannabinol) in hair. A 10 mg of hair sample was descontaminated by dichloromethane followed by alkalin digestion, headspace solid-phase microextraction technique (HS-SPME) and analyzed by gas chromatography-mass spectrometry (CG/MS). The detection and quantitation limits were 0,07 and 0,12ng/mg respectively for all studied cannabinoids. The method proved to be simple, fast, precise and linear at the range of 0,12 to 12ng/mg (r2 > 0,98). Eight hair samples of Cannabis user were collected from patients at admittance from a dependence clinic by clinical staff. The method showed efficient in samples of users who use the drug at least 10 fold a week.
|
92 |
Desenvolvimento de procedimentos analíticos explorando microextração líquido-líquido em fluxo para a determinação de espécies de interesse em águas e leite / Development of analytical procedures exploiting flow-based liquid-liquid microextraction for the determination of species of interest in waters and milkNascimento, Carina de Fátima 26 February 2018 (has links)
Três procedimentos analíticos envolvendo microextração líquido-líquido (MELL) em fluxo foram desenvolvidos para as determinações de formaldeído em leite, detergentes aniônicos em águas de rios e bisfenol A (BPA) em águas de torneira. Microextração líquido-líquido dispersiva (MELLD) foi empregada no primeiro e no segundo procedimentos. O primeiro procedimento foi conduzido em um sistema fluxo-batelada no qual a quantificação espectrofotométrica era realizada diretamente na câmara de mistura/reação, através do acoplamento de fibras ópticas. No segundo, foi explorada a estratégia lab-in-syringe, em que a formação do par iônico entre os detergentes aniônicos e corante catiônico azul de metileno, bem como MELLD ocorriam no interior da seringa, sendo os analitos quantificados na fase orgânica por espectrofotometria. O terceiro procedimento envolveu MELL em sistema de análises por injeção sequencial (SIA), baseada na formação de um filme de 1-octanol na parede da bobina de extração. O extrato foi eluído com etanol e a quantificação de BPA foi realizada por espectrofluorimetria. As linearidades das curvas analíticas, os limites de detecção e os limites de quantificação ao nível de 95% de confiança foram: 0,5-5,0 mg L-1, 100 e 300 ?g L-1 para formaldeído, 0,03-0,5 mg L-1, 9,0 e 29,0 ?g L-1 para detergentes, e 5,0 - 100 ?g L-1, 1,8 ?g L-1 e 5,4 ?g L-1 para BPA. Os procedimentos desenvolvidos não apresentaram efeitos de matriz, e as recuperações se situaram entre 91 e 112%. A precisão e exatidão do procedimento foram concordantes com os procedimentos de referência, ao nível de 95% de confiança. Todos os procedimentos apresentaram coeficientes de variação menores do que 3,5% (n=10), frequência de amostragem de 10-17 h-1, consumiram apenas 30-40 µL de solventes orgânicos e geraram 2,7-6,7 mL de resíduos por determinação / Three analytical procedures involving flow-based liquid-liquid microextraction (LLME) were developed for the determinations of formaldehyde in milk, anionic detergents in river waters, and bisphenol A (BPA) in tap waters. The first and second procedures involved dispersive liquid-liquid microextraction (DLLME) and spectrophotometric detection. The first one was carried out in a flow-batch system, in which the spectrophotometric quantification was performed directly in the mixing/reaction chamber by coupling optical fibers. The second one exploited the lab-in-syringe strategy, in which the ion-pair formation between the anionic detergents and the methylene blue cationic dye, as well as DLLME, were carried out inside the syringe. The third procedure involved LLME in a sequential injection system based on the formation of a 1-octanol film on the inner wall of the extraction coil. The extract was eluted with ethanol and BPA was quantified by spectrofluorimetry. Linear response ranges, detection and quantification limits estimated at the 95% confidence level were: 0.5-5.0 mg L-1, 100 and 300 ?g L-1 for formaldehyde; 0.03-0.5 mg L-1, 9.0 and 29.0 ?g L-1 for detergents, and 5.0-100 ?g L-1, 1.8 and 5.4 ?g L-1 for BPA. Matrix effects were not observed for the assayed samples and recoveries ranged from 91 to 112%. Accuracy and precision of the results agreed with those attained by reference procedures at the 95% confidence level. All procedures yielded coefficients of variation lower than 3.5% (n = 10), sampling rates within 10 and 17 h-1, consumed only 30-40 ?L of organic solvents, and generated 2.7-6.7 mL of waste by determination
|
93 |
Isoflurano : desenvolvimento de um método analítico empregando microextração em fase sólida, incorporação em nanoemulsões e avaliação biológica das nanoemulsõesKrahn, Carolina Lopes January 2010 (has links)
O objetivo do presente trabalho foi desenvolver e validar um método analítico empregando microextração em fase sólida (SPME) para detecção e quantificação de isoflurano (ISO) na forma volátil e incluso em nanoemulsões intravenosas e, ainda, avaliar o efeito biológico destas. A detecção do ISO foi realizada através de cromatografia em fase gasosa com detector de ionização de chama (CG/DIC). As condições ideais para realização da pré-concentração e extração de ISO através da técnica de SPME foram temperatura ambiente, agitação constante, 30 min de extração e 2 min de dessorção no injetor do CG. O método desenvolvido foi validado avaliando os parâmetros de especificidade, linearidade, limites de detecção e quantificação, precisão, exatidão e robustez. As nanoemulsões contendo ISO foram desenvolvidas através da homogeneização à alta pressão, e apresentaram diâmetro médio, índice de polidispersão, potencial zeta e pH de 150 ± 0,78 nm, 0,08 ± 0,01, - 18 ± 2,4 mV e 6,03 ± 0,04, respectivamente. O pH foi ajustado para 7,4 (valor fisiológico). O teor de ISO nas formulações foi de 98,4 %. Não houve modificação das características físico-químicas das nanoemulsões após 30 dias de armazenamento a 8 ºC. Análises de espalhamento de luz múltiplo não demonstraram tendência a fenômenos de instabilidade física para as formulações. Os estudos do efeito anestésico das nanoemulsões intravenosas contendo ISO em cães evidenciaram uma redução significativa (p < 0,05) na dose comparada com a administração de ISO volátil. Não houve alterações no débito cardíaco, saturação de oxigênio na hemoglobina e nos biomarcadores das funções renal, hepática e muscular. Uma queda na pressão arterial dos cães foi observada em todos os tratamentos devido ao efeito hipotensor do ISO. Após administração das nanoemulsões contendo ISO e branca, observou-se taquipnéia, edema, eritema, e baixas concentrações de dióxido de carbono expiradas. Assim, a nanoemulsificação do ISO foi realizada com sucesso e a aplicação na anestesia geral intravenosa foi demonstrada. / The aims of this work were to develop and validate an analytical method using solidphase microextraction (SPME) to detect and quantify isoflurane (ISO) inhalation liquid and loaded in intravenous nanoemulsions, and also evaluate the biological effect of the formulations. ISO detection was made by gas chromatography with flame ionization detector (GC/FID). The ideal conditions setting for the pre concentration and extraction of ISO through SPME were environmental temperature, constant stirring, 30 min for extraction and 2 min for analyte desorption in the GC inlet port. The developed method was validated by means of specificity, linearity, detection and quantification limits, precision, accuracy and robustness. The ISOloaded nanoemulsions were formulated by high-pressure homogenization, and presented average diameter, polydispersity index, zeta potential and pH of 150 ± 0.78 nm, 0.08 ± 0.01, -18 ± 2.4 mV and 6.03 ± 0.04, respectively. The pH was adjusted to 7.4 (physiological value). The drug content on the formulations was 98.4 %. After 30 days of storage at 8 ºC no changes on nanoemulsion’s physicalchemical characteristics were observed. Multiple light scattering analysis did not demonstrate any physical destabilization phenomena for the formulations. The anesthetic effect study for the intravenous ISO-loaded nanoemulsions in dogs highlighted a significant reduction (p < 0.05) in dosage regimen when compared to the volatile ISO administration. There were no alterations on cardiac rate, oxygen hemoglobin saturation and on biomarkers of the renal, hepatic and muscle functionalities. A decrease in dog’s arterial blood pressure in all treatments due the hypotensive effect caused by ISO was observed. After the administration of the nanomulsions, ISO-loaded and unloaded, occurred tachypnea, edema, erythema and low end tidal concentrations of carbon dioxide. Taking all above into account, the method was considered easy on execution and suitable for laboratory routines, the ISO nanoemulsification was made successfully and its application on general anesthesia was demonstrated.
|
94 |
Análise de efedrinas e anfetamina em urina empregando spe e spme por cg/em/em / Analysis of ephedrines and amphetamine in urine using spe and spme by gc/ms/msSebben, Viviane Cristina January 2007 (has links)
O Brasil ocupa posição de destaque no consumo mundial de anfetaminas, contrariamente à tendência mundial de retração. Devido aos efeitos colaterais e ao alto potencial de abuso, a produção e comercialização de anfetaminas vêm sendo controladas no mundo inteiro. Com a restrição de uso, houve um retorno a procura pelos equivalentes naturais, especialmente as efedrinas presentes em diversas especialidades farmacêuticas, utilizadas no tratamento de doenças respiratórias. São componentes de vários compostos emagrecedores, suplementos alimentares e dietéticos utilizados para perda de peso e ganho de massa muscular. Face ao uso indiscriminado e a grande incidência de resultados falso-positivos nos testes de triagem para anfetaminas por imunoensaio enzimático homogêneo, fazem-se necessários testes confirmatórios. Neste sentido, este trabalho se propôs a desenvolver um método confirmatório simples e rápido para detecção, identificação e quantificação de efedrinas (efedrina/pseudoefedrina) em amostras de urina por por cromatografia a gás / espectrometria de massas-massas (CG/EM/EM), passível de ser adotado na rotina de laboratórios de análises toxicológicas. Devido à complexidade da matriz e as peculiaridades do analito, inicialmente procedeu-se o estudo do tratamento da amostra, considerando as etapas de derivatização, extração, pré-concentração e purificação, de modo a fornecer um extrato límpido, livre de impurezas, interferentes e com melhor sensibilidade, linearidade e seletividade analítica. Os métodos de extração usados foram extração líquido-líquido (ELL), extração em fase sólida (SPE) e microextração em fase sólida (SPME). Os resultados indicaram que o reagente de derivatização ciclohexanona foi o que apresentou melhor desempenho, menor custo e promoveu maior seletividade dos diasterômeros EF/PEF em colunas normais de CG. Sendo que o método mais apropriado para a detecção e identificação de efedrinas/anfetamina por CG/EM é a SPME levando em consideração características como simplicidade, rapidez, custo, recuperação e ausência de interferentes. Entretanto, considera-se valido o uso de SPE para a quantificação, devido à possibilidade de pré-concentração do analito. / Brazil is one of the biggest amphetamine consumers in the world, going against the worldwide retraction tendency. Due to serious adverse effects and high abuse potential, the production and commercialization of amphetamines has been controlled around the world. With the restriction of its use, there was a return in the search of natural equivalents, especially the ephedrines found in many medicines utilized in the treatment of respiratory diseases. Furthermore, they are components of dietary supplements used to lose weight and muscular mass gain. Because of the indiscriminate use and the high incidence of false-positive results in the amphetamines screening tests by enzyme immunoassay technique, it is necessary confirmatory tests. In this way, the aim of this work is to develop a confirmatory simple and quickly method for the detection and quantification of ephedrines (ephedrine and pseudoephedrine) gas chromatography / mass-mass spectrometry (GC/MS/MS), with possibility to be adopted in toxicological analyses laboratorial routine. Due to the complexity of the matrix and analyte peculiarities, initially proceeds the study of sample treatment, considering the derivatization, extraction, pre-concentration and purification steps, obtaining a limpidous extract, free of impurities, interferents and with better sensitivity, linearity and analytical selectivity. The extraction method used were liquid-liquid extraction (LLE), solid-phase extraction (SPE) and solid-phase microextraction (SPME). The results indicate that cyclohexanone was the derivatization agent with the best performance, lower price and good selectivity in diasteromers EF/PEF separation in normal GC columns. The most appropriate method for detection and identification of ephedrines/amphetamine by GC/MS is SPME, considering characteristics as simplicity, speed, cost, recovery and absence of interferents. However, the use of SPE must be considered to quantification, since it allowed analyte pre-concentration.
|
95 |
Desenvolvimento de estratégias analíticas envolvendo microextração dispersiva e sistema em linha empregando extração no ponto-nuvem para a determinação de metaisBaliza, Patrícia Xavier 05 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-08T13:55:22Z
No. of bitstreams: 1
Tese-Paty.pdf: 1034475 bytes, checksum: 37ed961306f75730b2da341693d7846e (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-08T14:24:01Z (GMT) No. of bitstreams: 1
Tese-Paty.pdf: 1034475 bytes, checksum: 37ed961306f75730b2da341693d7846e (MD5) / Made available in DSpace on 2016-09-08T14:24:01Z (GMT). No. of bitstreams: 1
Tese-Paty.pdf: 1034475 bytes, checksum: 37ed961306f75730b2da341693d7846e (MD5) / FAPESB / No presente trabalho, é proposta a síntese de um novo reagente
derivado do tiazol, o 5-bromotiazolilazo-2-orcinol (Br-TAO) e a sua aplicação
em sistemas de pré-concentração de metais. O Br-TAO foi empregado em um
procedimento para a pré-concentração de cobalto utilizando a micro-extração
dispersiva líquido-líquido e determinação por espectrometria de absorção
atômica com chama (FAAS). O fator de enriquecimento e o limite de detecção
obtidos foram 16 e 0,9 µg L-1, respectivamente. A exatidão do método foi
testada por análise do material de referência certificado NIST 1570a, Folhas de
Espinafre. Este procedimento foi aplicado para a determinação de cobalto em
águas do Rio das Contas, localizado no município de Jequié-BA. Outro
procedimento empregou o reagente Br-TAO em um sistema em linha com
injeção seqüencial e extração no ponto-nuvem para pré-concentração e
determinação de manganês por FAAS. O procedimento foi baseado na
extração no ponto-nuvem de manganês no sistema de injeção seqüencial e
retenção em minicoluna, com posterior eluição e detecção. Variáveis químicas
e de fluxo que influenciam o sistema foram otimizadas e alguns parâmetros
analíticos determinados, como freqüência analítica (48 h-1), fator de
enriquecimento (14), índice de consumo (0,20 mL) e limite de detecção (0,5 µg
L-1). Os materiais de referência certificados NIST 1568a, Farinha de Arroz e
NIST 1573a, Folhas de Tomateiro, foram utilizados para o teste da exatidão do
procedimento. O método foi aplicado à determinação de manganês em farinhas
de arroz, láctea e de milho. Este trabalho faz parte de um projeto PRONEX,
financiado pelo CNPq/FAPESB e intitulado “Núcleo de pesquisas em Química
Analítica da Bahia: Química e qualidade em alimentos”. / In this paper, it is proposed the synthesis of a new reagent derivative of
thiazole, 5-bromothiazolylazo-2-orcinol (Br-TAO) and its application in systems
for preconcentration of metals. The reagent was synthesized by diazotization
and coupling reactions. Then the solid product was purified by recrystallization
with ethanol and characterized. The reagent Br-TAO was employed in a
preconcentration procedure for cobalt using microdispersive liquid-liquid
extraction and determination by flame atomic absorption spectrometry (FAAS).
The enrichment factor and the limit of detection were 16 and 0.9 µg L-1,
respectively. The accuracy was tested by analysis of certified reference material
NIST 1570a, Spinach Leaves. The procedure was applied to the determination
of cobalt in water from Rio de Contas, located in Jequié-BA. Another procedure
employed the reagent Br-TAO in an on-line system with sequential injection and
cloud point extraction for preconcentration and determination of manganese by
FAAS. The procedure is based on the cloud point extraction of manganese in
the sequential injection system and retention in a minicolumn, with subsequent
elution and detection. Chemical and flow variables that affect the system were
optimized and some specific analytical and some analytical parameters were
determined, such as analytical frequency (48 h-1), enrichment factor (14), rate of
consumption (0.20 mL) and the limit of detection (0.5 µg L-1). The certified
reference materials NIST 1568a, Rice Flour and NIST 1573a, tomato leaves
were used to test the accuracy of the procedure. The method was applied to the
determination of manganese in rice flour, milk and corn. This work is part of a
PRONEX project, funded by CNPq / FAPESB entitled "Center for Research in
Analytical Chemistry of Bahia: Chemistry and quality food."
|
96 |
Antiandrogênios em efluente hospitalar: extração com barras poliméricas, quantificação, identificação de metabólitos e subprodutos, proposição de rotas de degradação por processos avançados de oxidação / Antiandrogens in hospital effluent: extraction with polymer bars, quantification, identification of metabolites and subproducts and proposition of degradation routes by advanced oxidation processesBrenner, Carla Geane Brandenburg 12 April 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work, methods were developed for the determination of antiandrogens in hospital
effluent using the analytical technique HPLC-DAD. Microextraction techniques of
Spironolactone, Flutamide, Cyproterone and Tamoxifen were investigated: liquid-liquid
(LLME) and sorptive extraction (SBSE). For quantification of the analytes in hospital effluent
was used solid phase extraction (SPE) with recoveries of 75.0 to 109.0±1.0 to 13.0% in
aqueous solution and from 72.0 to 106.0±2.0 to 13.0% in hospital effluent. The average
concentrations of analytes in the effluent of emergency (PA) ranged from 0.00 to 11.70 μg L-1
(RSD 0.00 to 11.5%) and of general-HUSM 0.00 to 11.30 μg L-1 (0.00 to 6.78% RSD),
respectively. LC-ESI-MS/MS technique was used for fragmentation of the precursor ions, to
identify product ions, and for neutral mass loss. LC-ESI-QqLIT-MS/MS was used to identify
metabolites and subproducts. STR photoreactor of 800 mL was used for simple photolysis and
heterogeneous photocatalysis, and for ozonation, column reactor of 800 mL. Fractional
factorial design was applied to the extraction experiments, as well as, to AOPs. UV-radiation
was generated by mercury vapor lamp of 125 W and 401 W m-2. Polymer bars of
polydimethylsiloxane and polyurethane with TiO2 supported were developed for
photocatalysis. Kinetic studies of the degradation reactions were made, subproducts were
identified and fragmentation routes proposed. Metabolites were identified in hospital effluent.
Preliminary risk analysis revealed that spironolactone has lower environmental risk, and that
all analytes except tamoxifen, show PEC value > 0.01 μg L-1. / Neste trabalho foram desenvolvidos métodos para a determinação de antiandrogênios em
efluente hospitalar utilizando-se a técnica analítica de HPLC-DAD. Técnicas de
microextração de Espironolactona, Flutamida, Ciproterona e Tamoxifeno foram investigadas:
líquido-líquido (LLME) e extração sortiva (SBSE). Para a quantificação dos analitos em
efluente hospitalar foi usada extração em fase sólida (SPE) com recuperações de 75,0-
109,0±1,0-13,0%, em solução aquosa, e de 72,0-106,0±2,0-13,0%, em efluente hospitalar. As
concentrações médias dos analitos no efluente do pronto atendimento (PA) e geral-HUSM
variaram de 0,00-11,70 μg L-1 (RSD 0,00-11,5%) e 0,00-11,30 μg L-1 (RSD 0,00-6,78%),
respectivamente. A técnica de LC-ESI-MS/MS foi utilizada na fragmentação dos íons
precursores, na identificação dos íons-produto e perda de massa neutra. LC-ESI-QqLITMS/
MS foi usada na identificação de metabólitos e no estudo dos subprodutos. Fotorreator
STR de 800 mL foi usado para fotólise simples e fotocatálise heterogênea e, para ozonização,
reator tipo coluna de 800 mL. Planejamento fatorial fracionado foi aplicado nos experimentos
de extração, bem como, de PAOs. Radiação UV foi gerada com lâmpada de vapor de
mercúrio de 125 W e 401 W m-2. Barras poliméricas de polidimetilsiloxano e poliuretano com
TiO2 suportado foram desenvolvidas para a fotocatálise. Estudos cinéticos das reações de
degradação foram feitos, subprodutos foram identificados e rotas de fragmentação propostas.
Metabólitos foram identificados no efluente hospitalar. Análise preliminar de risco revelou
que a espironolactona apresenta menor risco ambiental e que todos os analitos, exceto
tamoxifeno, apresentam valor de PEC > 0,01 μg L-1.
|
97 |
Análise de efedrinas e anfetamina em urina empregando spe e spme por cg/em/em / Analysis of ephedrines and amphetamine in urine using spe and spme by gc/ms/msSebben, Viviane Cristina January 2007 (has links)
O Brasil ocupa posição de destaque no consumo mundial de anfetaminas, contrariamente à tendência mundial de retração. Devido aos efeitos colaterais e ao alto potencial de abuso, a produção e comercialização de anfetaminas vêm sendo controladas no mundo inteiro. Com a restrição de uso, houve um retorno a procura pelos equivalentes naturais, especialmente as efedrinas presentes em diversas especialidades farmacêuticas, utilizadas no tratamento de doenças respiratórias. São componentes de vários compostos emagrecedores, suplementos alimentares e dietéticos utilizados para perda de peso e ganho de massa muscular. Face ao uso indiscriminado e a grande incidência de resultados falso-positivos nos testes de triagem para anfetaminas por imunoensaio enzimático homogêneo, fazem-se necessários testes confirmatórios. Neste sentido, este trabalho se propôs a desenvolver um método confirmatório simples e rápido para detecção, identificação e quantificação de efedrinas (efedrina/pseudoefedrina) em amostras de urina por por cromatografia a gás / espectrometria de massas-massas (CG/EM/EM), passível de ser adotado na rotina de laboratórios de análises toxicológicas. Devido à complexidade da matriz e as peculiaridades do analito, inicialmente procedeu-se o estudo do tratamento da amostra, considerando as etapas de derivatização, extração, pré-concentração e purificação, de modo a fornecer um extrato límpido, livre de impurezas, interferentes e com melhor sensibilidade, linearidade e seletividade analítica. Os métodos de extração usados foram extração líquido-líquido (ELL), extração em fase sólida (SPE) e microextração em fase sólida (SPME). Os resultados indicaram que o reagente de derivatização ciclohexanona foi o que apresentou melhor desempenho, menor custo e promoveu maior seletividade dos diasterômeros EF/PEF em colunas normais de CG. Sendo que o método mais apropriado para a detecção e identificação de efedrinas/anfetamina por CG/EM é a SPME levando em consideração características como simplicidade, rapidez, custo, recuperação e ausência de interferentes. Entretanto, considera-se valido o uso de SPE para a quantificação, devido à possibilidade de pré-concentração do analito. / Brazil is one of the biggest amphetamine consumers in the world, going against the worldwide retraction tendency. Due to serious adverse effects and high abuse potential, the production and commercialization of amphetamines has been controlled around the world. With the restriction of its use, there was a return in the search of natural equivalents, especially the ephedrines found in many medicines utilized in the treatment of respiratory diseases. Furthermore, they are components of dietary supplements used to lose weight and muscular mass gain. Because of the indiscriminate use and the high incidence of false-positive results in the amphetamines screening tests by enzyme immunoassay technique, it is necessary confirmatory tests. In this way, the aim of this work is to develop a confirmatory simple and quickly method for the detection and quantification of ephedrines (ephedrine and pseudoephedrine) gas chromatography / mass-mass spectrometry (GC/MS/MS), with possibility to be adopted in toxicological analyses laboratorial routine. Due to the complexity of the matrix and analyte peculiarities, initially proceeds the study of sample treatment, considering the derivatization, extraction, pre-concentration and purification steps, obtaining a limpidous extract, free of impurities, interferents and with better sensitivity, linearity and analytical selectivity. The extraction method used were liquid-liquid extraction (LLE), solid-phase extraction (SPE) and solid-phase microextraction (SPME). The results indicate that cyclohexanone was the derivatization agent with the best performance, lower price and good selectivity in diasteromers EF/PEF separation in normal GC columns. The most appropriate method for detection and identification of ephedrines/amphetamine by GC/MS is SPME, considering characteristics as simplicity, speed, cost, recovery and absence of interferents. However, the use of SPE must be considered to quantification, since it allowed analyte pre-concentration.
|
98 |
Isoflurano : desenvolvimento de um método analítico empregando microextração em fase sólida, incorporação em nanoemulsões e avaliação biológica das nanoemulsõesKrahn, Carolina Lopes January 2010 (has links)
O objetivo do presente trabalho foi desenvolver e validar um método analítico empregando microextração em fase sólida (SPME) para detecção e quantificação de isoflurano (ISO) na forma volátil e incluso em nanoemulsões intravenosas e, ainda, avaliar o efeito biológico destas. A detecção do ISO foi realizada através de cromatografia em fase gasosa com detector de ionização de chama (CG/DIC). As condições ideais para realização da pré-concentração e extração de ISO através da técnica de SPME foram temperatura ambiente, agitação constante, 30 min de extração e 2 min de dessorção no injetor do CG. O método desenvolvido foi validado avaliando os parâmetros de especificidade, linearidade, limites de detecção e quantificação, precisão, exatidão e robustez. As nanoemulsões contendo ISO foram desenvolvidas através da homogeneização à alta pressão, e apresentaram diâmetro médio, índice de polidispersão, potencial zeta e pH de 150 ± 0,78 nm, 0,08 ± 0,01, - 18 ± 2,4 mV e 6,03 ± 0,04, respectivamente. O pH foi ajustado para 7,4 (valor fisiológico). O teor de ISO nas formulações foi de 98,4 %. Não houve modificação das características físico-químicas das nanoemulsões após 30 dias de armazenamento a 8 ºC. Análises de espalhamento de luz múltiplo não demonstraram tendência a fenômenos de instabilidade física para as formulações. Os estudos do efeito anestésico das nanoemulsões intravenosas contendo ISO em cães evidenciaram uma redução significativa (p < 0,05) na dose comparada com a administração de ISO volátil. Não houve alterações no débito cardíaco, saturação de oxigênio na hemoglobina e nos biomarcadores das funções renal, hepática e muscular. Uma queda na pressão arterial dos cães foi observada em todos os tratamentos devido ao efeito hipotensor do ISO. Após administração das nanoemulsões contendo ISO e branca, observou-se taquipnéia, edema, eritema, e baixas concentrações de dióxido de carbono expiradas. Assim, a nanoemulsificação do ISO foi realizada com sucesso e a aplicação na anestesia geral intravenosa foi demonstrada. / The aims of this work were to develop and validate an analytical method using solidphase microextraction (SPME) to detect and quantify isoflurane (ISO) inhalation liquid and loaded in intravenous nanoemulsions, and also evaluate the biological effect of the formulations. ISO detection was made by gas chromatography with flame ionization detector (GC/FID). The ideal conditions setting for the pre concentration and extraction of ISO through SPME were environmental temperature, constant stirring, 30 min for extraction and 2 min for analyte desorption in the GC inlet port. The developed method was validated by means of specificity, linearity, detection and quantification limits, precision, accuracy and robustness. The ISOloaded nanoemulsions were formulated by high-pressure homogenization, and presented average diameter, polydispersity index, zeta potential and pH of 150 ± 0.78 nm, 0.08 ± 0.01, -18 ± 2.4 mV and 6.03 ± 0.04, respectively. The pH was adjusted to 7.4 (physiological value). The drug content on the formulations was 98.4 %. After 30 days of storage at 8 ºC no changes on nanoemulsion’s physicalchemical characteristics were observed. Multiple light scattering analysis did not demonstrate any physical destabilization phenomena for the formulations. The anesthetic effect study for the intravenous ISO-loaded nanoemulsions in dogs highlighted a significant reduction (p < 0.05) in dosage regimen when compared to the volatile ISO administration. There were no alterations on cardiac rate, oxygen hemoglobin saturation and on biomarkers of the renal, hepatic and muscle functionalities. A decrease in dog’s arterial blood pressure in all treatments due the hypotensive effect caused by ISO was observed. After the administration of the nanomulsions, ISO-loaded and unloaded, occurred tachypnea, edema, erythema and low end tidal concentrations of carbon dioxide. Taking all above into account, the method was considered easy on execution and suitable for laboratory routines, the ISO nanoemulsification was made successfully and its application on general anesthesia was demonstrated.
|
99 |
Isoflurano : desenvolvimento de um método analítico empregando microextração em fase sólida, incorporação em nanoemulsões e avaliação biológica das nanoemulsõesKrahn, Carolina Lopes January 2010 (has links)
O objetivo do presente trabalho foi desenvolver e validar um método analítico empregando microextração em fase sólida (SPME) para detecção e quantificação de isoflurano (ISO) na forma volátil e incluso em nanoemulsões intravenosas e, ainda, avaliar o efeito biológico destas. A detecção do ISO foi realizada através de cromatografia em fase gasosa com detector de ionização de chama (CG/DIC). As condições ideais para realização da pré-concentração e extração de ISO através da técnica de SPME foram temperatura ambiente, agitação constante, 30 min de extração e 2 min de dessorção no injetor do CG. O método desenvolvido foi validado avaliando os parâmetros de especificidade, linearidade, limites de detecção e quantificação, precisão, exatidão e robustez. As nanoemulsões contendo ISO foram desenvolvidas através da homogeneização à alta pressão, e apresentaram diâmetro médio, índice de polidispersão, potencial zeta e pH de 150 ± 0,78 nm, 0,08 ± 0,01, - 18 ± 2,4 mV e 6,03 ± 0,04, respectivamente. O pH foi ajustado para 7,4 (valor fisiológico). O teor de ISO nas formulações foi de 98,4 %. Não houve modificação das características físico-químicas das nanoemulsões após 30 dias de armazenamento a 8 ºC. Análises de espalhamento de luz múltiplo não demonstraram tendência a fenômenos de instabilidade física para as formulações. Os estudos do efeito anestésico das nanoemulsões intravenosas contendo ISO em cães evidenciaram uma redução significativa (p < 0,05) na dose comparada com a administração de ISO volátil. Não houve alterações no débito cardíaco, saturação de oxigênio na hemoglobina e nos biomarcadores das funções renal, hepática e muscular. Uma queda na pressão arterial dos cães foi observada em todos os tratamentos devido ao efeito hipotensor do ISO. Após administração das nanoemulsões contendo ISO e branca, observou-se taquipnéia, edema, eritema, e baixas concentrações de dióxido de carbono expiradas. Assim, a nanoemulsificação do ISO foi realizada com sucesso e a aplicação na anestesia geral intravenosa foi demonstrada. / The aims of this work were to develop and validate an analytical method using solidphase microextraction (SPME) to detect and quantify isoflurane (ISO) inhalation liquid and loaded in intravenous nanoemulsions, and also evaluate the biological effect of the formulations. ISO detection was made by gas chromatography with flame ionization detector (GC/FID). The ideal conditions setting for the pre concentration and extraction of ISO through SPME were environmental temperature, constant stirring, 30 min for extraction and 2 min for analyte desorption in the GC inlet port. The developed method was validated by means of specificity, linearity, detection and quantification limits, precision, accuracy and robustness. The ISOloaded nanoemulsions were formulated by high-pressure homogenization, and presented average diameter, polydispersity index, zeta potential and pH of 150 ± 0.78 nm, 0.08 ± 0.01, -18 ± 2.4 mV and 6.03 ± 0.04, respectively. The pH was adjusted to 7.4 (physiological value). The drug content on the formulations was 98.4 %. After 30 days of storage at 8 ºC no changes on nanoemulsion’s physicalchemical characteristics were observed. Multiple light scattering analysis did not demonstrate any physical destabilization phenomena for the formulations. The anesthetic effect study for the intravenous ISO-loaded nanoemulsions in dogs highlighted a significant reduction (p < 0.05) in dosage regimen when compared to the volatile ISO administration. There were no alterations on cardiac rate, oxygen hemoglobin saturation and on biomarkers of the renal, hepatic and muscle functionalities. A decrease in dog’s arterial blood pressure in all treatments due the hypotensive effect caused by ISO was observed. After the administration of the nanomulsions, ISO-loaded and unloaded, occurred tachypnea, edema, erythema and low end tidal concentrations of carbon dioxide. Taking all above into account, the method was considered easy on execution and suitable for laboratory routines, the ISO nanoemulsification was made successfully and its application on general anesthesia was demonstrated.
|
100 |
Análise de efedrinas e anfetamina em urina empregando spe e spme por cg/em/em / Analysis of ephedrines and amphetamine in urine using spe and spme by gc/ms/msSebben, Viviane Cristina January 2007 (has links)
O Brasil ocupa posição de destaque no consumo mundial de anfetaminas, contrariamente à tendência mundial de retração. Devido aos efeitos colaterais e ao alto potencial de abuso, a produção e comercialização de anfetaminas vêm sendo controladas no mundo inteiro. Com a restrição de uso, houve um retorno a procura pelos equivalentes naturais, especialmente as efedrinas presentes em diversas especialidades farmacêuticas, utilizadas no tratamento de doenças respiratórias. São componentes de vários compostos emagrecedores, suplementos alimentares e dietéticos utilizados para perda de peso e ganho de massa muscular. Face ao uso indiscriminado e a grande incidência de resultados falso-positivos nos testes de triagem para anfetaminas por imunoensaio enzimático homogêneo, fazem-se necessários testes confirmatórios. Neste sentido, este trabalho se propôs a desenvolver um método confirmatório simples e rápido para detecção, identificação e quantificação de efedrinas (efedrina/pseudoefedrina) em amostras de urina por por cromatografia a gás / espectrometria de massas-massas (CG/EM/EM), passível de ser adotado na rotina de laboratórios de análises toxicológicas. Devido à complexidade da matriz e as peculiaridades do analito, inicialmente procedeu-se o estudo do tratamento da amostra, considerando as etapas de derivatização, extração, pré-concentração e purificação, de modo a fornecer um extrato límpido, livre de impurezas, interferentes e com melhor sensibilidade, linearidade e seletividade analítica. Os métodos de extração usados foram extração líquido-líquido (ELL), extração em fase sólida (SPE) e microextração em fase sólida (SPME). Os resultados indicaram que o reagente de derivatização ciclohexanona foi o que apresentou melhor desempenho, menor custo e promoveu maior seletividade dos diasterômeros EF/PEF em colunas normais de CG. Sendo que o método mais apropriado para a detecção e identificação de efedrinas/anfetamina por CG/EM é a SPME levando em consideração características como simplicidade, rapidez, custo, recuperação e ausência de interferentes. Entretanto, considera-se valido o uso de SPE para a quantificação, devido à possibilidade de pré-concentração do analito. / Brazil is one of the biggest amphetamine consumers in the world, going against the worldwide retraction tendency. Due to serious adverse effects and high abuse potential, the production and commercialization of amphetamines has been controlled around the world. With the restriction of its use, there was a return in the search of natural equivalents, especially the ephedrines found in many medicines utilized in the treatment of respiratory diseases. Furthermore, they are components of dietary supplements used to lose weight and muscular mass gain. Because of the indiscriminate use and the high incidence of false-positive results in the amphetamines screening tests by enzyme immunoassay technique, it is necessary confirmatory tests. In this way, the aim of this work is to develop a confirmatory simple and quickly method for the detection and quantification of ephedrines (ephedrine and pseudoephedrine) gas chromatography / mass-mass spectrometry (GC/MS/MS), with possibility to be adopted in toxicological analyses laboratorial routine. Due to the complexity of the matrix and analyte peculiarities, initially proceeds the study of sample treatment, considering the derivatization, extraction, pre-concentration and purification steps, obtaining a limpidous extract, free of impurities, interferents and with better sensitivity, linearity and analytical selectivity. The extraction method used were liquid-liquid extraction (LLE), solid-phase extraction (SPE) and solid-phase microextraction (SPME). The results indicate that cyclohexanone was the derivatization agent with the best performance, lower price and good selectivity in diasteromers EF/PEF separation in normal GC columns. The most appropriate method for detection and identification of ephedrines/amphetamine by GC/MS is SPME, considering characteristics as simplicity, speed, cost, recovery and absence of interferents. However, the use of SPE must be considered to quantification, since it allowed analyte pre-concentration.
|
Page generated in 0.0624 seconds