Spelling suggestions: "subject:"leakage.""
71 |
Dlouhodobá odolnost okrajového uzávěru kompozitních výplní v prostředí se zvýšeným korozním rizikem / Long-term durability of composite restoration margins in environments with increased corrosion riskRoubíčková, Adéla January 2013 (has links)
Introduction: An adhesive bond between hard dental tissues and composite reconstructions is exposed to mechanical load, water, bacteria, enzymes and different chemical compounds. These factors could impair durability and resistance of composite reconstructions. In contrast with extensive research of negative influence of water on degradation of adhesive bonds, the influence of chemical substances on adhesive bond has not been investigated to a greater extent. Aim: The aim of the experimental part of the thesis was to evaluate the influence of hydrogen peroxide containing tooth-whitening products and mouth rinses containing chlorhexidine and fluoride on a long-term stability of class V composite restorations created using four contemporary adhesive systems by a microleakage method. Materials and methods: The following adhesive systems were investigated: total-etch Gluma Comfort Bond (GLU), and self-etch adhesives Clearfil SE Bond (CLF), Adper Prompt (ADP) and iBond (IBO). Standardized class V cavities were prepared in 192 extracted human teeth (one cervical margin in the cementum and one in the enamel). Subsequently, the cavities were restored using microhybride composite Charisma. The specimens were then exposed to the tooth whitening system Opalescence PF 20, mouth rinse Corsodyl containing...
|
72 |
Avaliação in vitro das interfaces dos implantes Cone Morse e Hexágono Interno / In vitro evaluation of the interfaces of the Morse Taper implants and Internal hexagon implants.Roberta Pires Dias Brosco 29 January 2014 (has links)
Objetivo: Considerando que a precisão na adaptação do implante ao intermediário transmucoso é fator importante para a longevidade da prótese e que os sistemas de implantes possuem origens diversas na sua fabricação, nos propusemos a verificar a infiltração da bactéria Enterococcus faecalis na interface entre intermediário transmucoso e implantes do tipo Cone Morse e Hexágono Interno no sistema Neodent . Material e Método: A amostra foi composta por 20 implantes do tipo Cone Morse com Index Protético, 20 implantes Titamax Cone Morse e 20 implantes de Hexágono Interno e 20 intermediários transmucosos do tipo Munhão Universal CM Exact, 20 Munhão Universal em corpo único de 3,3 x 5,5 mm e 20 Munhão Universal II Plus com Parafuso. Com o auxílio da Micropipeta o Inóculo foi aspirado, imediatamente após, inserido no interior do implante que se encontrava estático na placa do Dispositivo desenvolvido para este experimento. Os intermediários foram então conectados e apertados com chave digital própria, em seguida, foi dado o torque ao parafuso do intermediário de acordo com as recomendações do fabricante. Após o torque o conjunto, implante-intermediário foi removido da placa do Dispositivo com pinça de titânio e inserido dentro do tubo de ensaio que continha o meio de cultura estéril. Diante do conhecimento da área interna de cada implante, o volume do Inóculo a ser utilizado foi determinado em 1L. Todos os tubos contendo os conjuntos foram numerados e incubados a 37oC por um período de 14 dias. Foi realizado acompanhamento diário para verificação da possível passagem de bactérias do interior do implante para o caldo. O indicativo da passagem de bactéria para o meio foi a turvação do meio de cultura (caldo BHI). Decorrido os 14 dias de observação, os dados foram tabulados e submetidos à Análise de Variância (ANOVA) com nível de significância de 5%, quando detectada diferença estatística, os valores foram submetidos ao Teste de Tuckey para comparações múltiplas. Resultados: O Teste de Tukey evidenciou que houve diferença estatisticamente significante entre o grupo de implantes Cone Morse, Cone Morse Índex e Hexágono Interno, onde o grupo de implantes Cone Morse diferiu estatisticamente do grupo Cone Morse Índex e também do grupo de implantes de Hexágono Interno. O grupo de implantes Cone Morse Índex não diferiu estatisticamente do grupo de implantes de Hexágono Interno, porém o grupo Cone Morse Índex presentou os melhores resultados. / Objective: Whereas the accuracy adaptation of the implant abutment is an important factor for the longevity of the prosthesis, and implant systems have diverse backgrounds in its manufacture, we set out to verify the infiltration of Enterococcus faecalis bacteria at the interface between the abutment and transmucosal implants of Morse Taper and Internal Hex of Neodent system. Material and Methods: The sample consisted of 20 Morse Taper implants, 20 Titamax Morse Taper implants, 20 Internal Hexagon implants and 20 transmucosal Exact CM Universal Post abutment, 20 Universal Post 3 in one body , 3 x 5.5mm and 20 Universal Post II Plus with Screw . With the aid of a micropipette the inoculum was aspirated, immediately thereafter, inserted into the implant that was in the static device board developed for this experiment. The abutments were then connected and tightened to own digital key, then the torque was given to the screw of the abutment according to the manufacturer\'s recommendations. After the torque, deploy abutment was removed from the plate clamp device of titanium and inserted into a test tube containing sterile culture. According to the internal area of each implant, the inoculum size was determined to be 1L. All the tubes were numbered and incubated at 37 ° C for a period of 14 days. Daily monitoring to check the possible passage of bacteria into the interior of the implant broth was carried out. The indication of the passage of bacteria was turbidity of the culture (BHI). Upon expiry of the 14 days of observation, the data were tabulated and an analysis of variance (ANOVA) with a significance level of 5 % was done. The values were submitted to Tukey test for multiple comparisons. Results: The Tukey test showed a statistically significant difference between the group of Morse Taper implants, Cone Morse Index and Internal Hex, where the group of implants differed from Morse Taper, Morse Taper Index group and also the group of Internal Hexagon implants. The group of Morse Taper implants Index did not differ statistically from the group of Internal hexagon implants, but Morse Taper Index group showed the best results
|
73 |
Microinfiltração e adaptação marginal de restaurações classe V simulando lesões de abfração / Microleakage and marginal adaptation of class v restorations simulating the abfraction lesionsAdriana de Fátima Vasconcelos Pereira 10 December 2007 (has links)
Avaliou-se in vitro restaurações classe V, simulando a configuração cavitária de lesões de abfração, quanto à microinfiltração e adaptação marginal. Sessenta pré-molares superiores foram divididos em seis grupos (n = 10), variando a combinação restauradora: G1 = Ketac Molar Liquid/Ketac Molar Easymix, G2 = Primer/Vitremer, G3 = Adper Single Bond 2/Durafill, G4 = Adper Single Bond 2/Z100, G5 = Clearfil SE Bond/Durafill e G6 = Clearfil SE Bond/Z100. Réplicas à base de resina poliéster foram obtidas como controle positivo para avaliação da adaptação após os ensaios laboratoriais. Todos os dentes foram submetidos à ciclagem térmica (1000 ciclos/5º-55ºC), ciclagem mecânica (100.000 ciclos/8kgf) e imersos em solução aquosa de azul de metileno 0,5% (pH 7,2) por 4h. Os espécimes foram seccionados longitudinal e transversalmente, obtendo-se duas partes. O grau de microinfiltração foi avaliado através de dois métodos, um qualitativo, por meio de escores atribuídos por três observadores, e outro quantitativo, usando o software Imagelab 2000. A análise de elementos finitos foi realizada para verificar a concentração de tensões na região cervical por meio da confecção de três modelos 3D de pré-molares, com o objetivo de representar o ensaio de ciclagem mecânica. Os resultados tratados pelo teste Kruskal-Wallis mostraram diferença estatística significativa (p < 0,05) para a margem em dentina, obtendo os menores valores de microinfiltração em ambos os métodos para G2, G5 e G6, respectivamente. Não houve diferença significante para a margem em esmalte. Para a adaptação marginal, os achados não revelaram diferença estatisticamente significante entre os substratos dentários (p < 0,05). O coeficiente de Spearman demonstrou correlação direta entre os métodos de avaliação para esmalte e dentina (p < 0,0001). As freqüências de ocorrência de desadaptação marginal foram comparadas pelo teste do Qui-quadrado para esmalte e dentina. Os dados não demonstraram diferença estatisticamente significante. A análise de elementos finitos constatou maior concentração de tensões de tração na dentina radicular no mesmo lado da aplicação da carga e no modelo restaurado com Z100. Concluiu-se que o cimento de ionômero de vidro modificado por resina, seguido das combinações restauradoras Clearfil SE Bond/Z100 e Clearfil SE Bond/Durafill VS, são os mais indicados para restaurações em áreas de abfração quando comparados aos outros materiais testados. / This in vitro study evaluated class V restorations simulating the wedge-shaped lesions as a function of the microleakage and marginal adaptation. Sixty upper premolars were divided into six groups (n = 10) using such restorative combinations: G1 = Ketac Molar Liquid/Ketac Molar Easymix, G2 = Primer/Vitremer, G3 = Adper Single Bond 2/Durafill, G4 = Adper Single Bond 2/Z100, G5 = Clearfil SE Bond/Durafill, G6 = Clearfil SE Bond/Z100. The poliester resin replicas were obtained as positive control for adaptation assessment after laboratory essays. All the teeth were subjected to thermocycling (1000 cycles/5°-55°C), mechanical load cycling (100.000 cycles/8Kgf), and immersed in 0,5% methylene blue dye (pH 7,2) for 4 hours. Then the specimens were sectioned longitudinally and transversally to obtain two parts of them. The microleakage degrees were assessed by qualitative and quantitative methods. The finite element analysis was performed in order to verify stress concentration at the cervical region. For this purpose, three 3D finite element models of premolars were created and then compared to mechanical load cycling. The results were submitted to Kruskal-Wallis test being statistically significant for the cervical dentin margin with lower microleakage values in both methods for G2, G5 and G6, respectively (p < 0, 05). The cervical enamel margin had no significant difference for microleakage values. For marginal adaptation, there was no statistically difference among the substrates (p < 0, 05). Spearman coefficient has showed a direct correlation between enamel and dentin (p < 0, 0001). The frequency of loss of marginal fit was calculated by Qui-square test. The data have shown no significant difference. The finite element analysis has presented higher tensile stresses at the root dentin at the same side of load direction and in the model restored by Z100. It has concluded that resin-modified glass ionomer cements, followed by Clearfil SE Bond/Durafill and Clearfil SE Bond/Z100 are the most indicated dental materials to restore abfraction lesions with comparison to other ones tested.
|
74 |
Efeito de diferentes agentes de limpeza cavitária sobre o selamento marginal em cavidades classe II sob microscopia óptica e microscopia eletrônica de varreduraSilveira, Werônica Jaernevay 24 May 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-04-11T12:29:16Z
No. of bitstreams: 1
weronicajaernevaysilveira.pdf: 883492 bytes, checksum: fb20cbb399eb197086af884c019a5c4b (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T03:38:18Z (GMT) No. of bitstreams: 1
weronicajaernevaysilveira.pdf: 883492 bytes, checksum: fb20cbb399eb197086af884c019a5c4b (MD5) / Made available in DSpace on 2016-04-24T03:38:18Z (GMT). No. of bitstreams: 1
weronicajaernevaysilveira.pdf: 883492 bytes, checksum: fb20cbb399eb197086af884c019a5c4b (MD5)
Previous issue date: 2013-05-24 / Neste estudo foi avaliado in vitro o selamento marginal em restaurações classe II
com resina composta nanoparticulada utilizando cinco diferentes agentes de limpeza
cavitária por meio de microscopia óptica e microscopia eletrônica de varredura. Vinte
e cinco molares humanos hígidos foram utilizados, nos quais foram realizadas
cavidades tipo slot vertical, mesial e distal, com término gengival abaixo da junção
esmalte-cemento. Os dentes foram divididos aleatoriamente em cinco grupos, de
acordo com o agente de limpeza empregado (n=10): Grupo Controle – uso de jato
de ar/água; Grupo I – solução de ácido fosfórico a 10%; Grupo II – solução de ácido
cítrico a 10%; Grupo III – solução de Clorexidina a 2%; Grupo IV – solução de EDTA
a 17%. As cavidades foram restauradas com sistema adesivo convencional de três
passos Scotchbond Multi-purpose eresina composta nanoparticulada Z350 ambos
da 3M-ESPE. Os espécimes foram submetidos à 5000 ciclos com temperaturas de
5ºC + 2ºC e 55ºC+ 2ºC, em banhos alternados de 30 segundos cada.
Posteriormente, os espécimes foram imersos por 24 horas em solução de nitrato de
prata amoniacal, em seguida em revelador radiográfico por 8 horas sob luz
fluorescente. Foram seccionados no sentido mesio-distal para avaliação da
microinfiltração marginal em microscopio óptico e eletrônico de varredura por meio
de escores. Os resultados foram submetidos a análise estatística pelo teste nãoparamétrico
de Kruskal Wallis, e análise de Variância de Mann-Whitney com
significância de 5%. Pode-se concluir que a substância desmineralizante EDTA foi o
agente de limpeza cavitária que teve maior percentual de escore 3, logo menor
occorrência de microinfiltraçãol quando comparado as demais substâncias testadas.
O ácido cítrico a 10% apresentou piores resultados, não sendo, portanto seu uso
indicado como agente de limpeza cavitária. Em relação ao ácido fosfórico 10%,
Clorexidina a 2% e a água destilada, os mesmos não tiverem diferenças
estatisticamente significantes. Sendo assim, diante dos resultados não se pode
afirmar que as substâncias desmineralizantes são mais eficazes que as não
desmineralizantes, quando avaliados em microscopia óptica e microscopia eletrônica
de varredura. / This study evaluated the in vitro microleakage in class II restorations with composite
nanoparticles using five different cleaning agents cavity by means of optical
microscopy and scanning electron microscopy. Twenty-five human molars were used,
which were performed in the vertical slot type cavities, mesial and distal gingival
ending below the cemento-enamel junction. The teeth were randomly divided into five
groups, according to the cleaning agent used (n = 10): control group - use of air jet /
water; Group I - solution of phosphoric acid 10%, Group II - solution citric acid 10%,
Group III - Chlorhexidine Solution 2% and Group IV - EDTA solution to 17%. The
cavities were restored with conventional adhesive system of three steps Scotchbond
Multi-purpose composite nanoparticle eresina both Z350 3M ESPE. The specimens
were subjected to 5000 cycles with temperatures of 5 º C + 2 º C and 55 º C + 2 º C
in alternating baths of 30 seconds each. Subsequently, the specimens were
immersed for 24 hours in a solution of ammoniacal silver nitrate, then in radiographic
developer for 8 hours under fluorescent light. Were sectioned mesio-distal to
evaluate the microleakage in optical microscope and scanning electron microscope
by means of scores. The results were statistically analyzed by the non-parametric
Kruskal Wallis analysis of variance and the Mann-Whitney test with significance level
of 5%. It can be concluded that the substance EDTA demineralization was cleaning
agent cavity that had the greatest number of scores 3, lower right occorrência
microinfiltraçãol when compared to the other substances tested. Citric acid 10% had
worse outcomes, and therefore not its intended use as a cleaning agent cavity.
Relative to 10% phosphoric acid, Chlorhexidine 2% and distilled water, they do not
have statistically significant differences. Thus, before the results can not be said that
the demineralizing substances are more effective than non demineralization, when
evaluated in light microscopy and scanning electron microscopy.
|
75 |
Efeito das técnicas de polimento e tempo na rugosidade superficial, dureza e microinfiltração de restaurações de resina composta após um ano de armazenagem / Effect of polishing techniques and time on surface roughness, microhardness and microleakage of resin composite restorations after oneyear storageVENTURINI, Daniela 30 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:17Z (GMT). No. of bitstreams: 1
Dissertacao_Daniela_Venturini.pdf: 913438 bytes, checksum: e17fa4ddbe1c025e3411319cac841d1e (MD5)
Previous issue date: 2006-06-30 / This study evaluated the effects of immediate and delayed polishing on surface roughness (Ra), microhardness (KHN) and microleakage of a microfilled composite (Filtek A110) and a hybrid composite (Filtek Z250) restorations after one-year
storage. Standardized cavities preparations were made in the buccal surface of 256 bovine teeth; half were restored with each composite. Immediately after photo activation finishing was carried out with #280 grit sandpaper. For each composite, the specimens were randomly allocated for two sub-groups. The first group (IM) was immediately polished, using three different systems (n=16): A- Sof-Lex; B- Flexicups; and C- a sequential technique using Flexicups, Jiffy Polishing Brush and Flexibuffs. The specimens were stored in saline solution at 37ºC. The second group (DE) was stored for two weeks and then polished with the same systems. Part of the specimens had their surface properties analyzed at the baseline, and the remaining specimens were stored for one-year in distilled water at 37ºC. Five readings per specimen were taken for each specimen regarding surface roughness and microhardness. After immersion in basic fuchsin, microleakage was evaluated (X40) using standardized scores. Data were analyzed at significance level of 0.05 with analysis of variance and a SNK test (surface roughness and microhardness) or with Mann-Whitney and Kruskal-Wallis (microleakage). For comparison between baseline and one-year Student´s t test (Ra) and Mann-Withney (microleakage) were carried out. After one-year, in general microfilled composite specimens showed lower
roughness and hardness. No difference regarding microleakage was observed among different groups, but better sealing was observed in enamel margins. The sequential technique provided the lowest roughness and the Sof-Lex the lowest hardness in the most of the experimental conditions. Aging increased composite roughness. Immediate polishing showed similar or better performance than delayed polishing for microleakage and surface roughness, but this was not observed for microhardness, except in sequential technique groups / Este estudo avaliou os efeitos do polimento imediato e mediato na rugosidade média superficial (Ra), dureza Knoop (KHN) e microinfiltração de um compósito microparticulado (Filtek A110) e um híbrido (Filtek Z250), após um ano de armazenagem dos espécimes. Preparos padronizados de 3mm mesio-distais, 3mm
inciso-cervicais e 2mm de profundidade foram realizados na face vestibular de 256 incisivos bovinos, metade destes foi restaurada com cada tipo de compósito. Imediatamente após a fotoativação realizado o acabamento com lixa d água de
granulação 280. Os espécimes restaurados com cada compósito foram divididos em dois grupos. O primeiro grupo (IM) foi polido imediatamente após o acabamento, usando três sistemas diferentes (n=16): A- Sof-Lex (3M-ESPE), B- FlexiCups (Cosmedent), C- (técnica seqüencial)- a seqüência de FlexiCups, Jiffy Polishing Brush (Ultradent) e FlexiBuffs (Cosmedent). Os espécimes foram então armazenados em solução salina a 37ºC. O segundo grupo (ME) foi armazenado por duas semanas e então polido com os mesmos sistemas. Parte dos espécimes foi analisada numa primeira etapa do experimento e o restante ficou armazenado por um ano em água destilada a 37ºC. Cinco leituras por espécimes foram realizadas para Ra e KHN. Após imersão em fucsina básica realizou-se o teste de penetração de corante sendo após analisado sob aumento (40x) usando escores padrão. Os
dados foram verificados através de Análise de Variância e teste SNK (Ra e KHN). Também foram utilizados os testes de Mann-Whitney ou Kruskal-Wallis (microinfiltração). Para comparação com os dados baseline foram utilizados os testes t de Student (Ra) e Mann-Withney (infiltração marginal). Todos os testes foram executados com significância de 5%. Após um ano de armazenagem os espécimes do compósito A110 apresentaram significativamente menor rugosidade e menor dureza. A técnica seqüencial promoveu a menor rugosidade e os discos Sof-Lex a menor dureza, essas diferenças foram estatisticamente significantes. Os escores de infiltração marginal foram semelhantes entre os grupos. Após um ano de
armazenagem os espécimes apresentaram um aumento significativo na rugosidade. O polimento IM mostrou-se igual, ou melhor, que o ME tanto para a infiltração marginal como para a rugosidade superficial para a maioria dos grupos analisados, no entanto tal fato não foi observado quanto à dureza superficial, exceto quando foi utilizada a técnica seqüencial
|
76 |
A shear bond strength, microleakage and laser microscopic study of two dental compomers.Moodley, Desi January 1999 (has links)
Magister Chirurgiae Dentium (MChD) / Purpose: To evaluate and compare the in-vitro shear bond strength and micro leakage of two compomers with their adhesive systems and to examine the dentine-restorative interface under confocal scanning laser microscopy (CSLM). Matoiats and Methods: For shear bond strength (SBS) testing thirty non-carious human molars were used of which fifteen molars were restored with Dyract AP using Non-Rinse Conditioner (NRC) and Prime&Bond NT (PBNT) and fifteen were restored with F2000 and Scotchbond Multi-Purpose Plus (SBMP). For the microleakage evaluation cavity preparations were made on the facial surfaces of thirty non-carious premolars. These were then restored with the
respective compomer system. The specimens were thermocycled, sectioned and examined for dye penetration. The dentine-restorative interface was examined through a confocal scanning laser microscope. The primers of the bonding agents were labelled with rhodamine B and the adhesive resins were labelled with fluorescein and examined under CSLM in fluorescent mode. Results: The mean SBS for PBNT and SBMP were 12.8 and 18.1 MPa, respectively. The microleakage scores showed Dyract with PBNT leaked on the dentine side in 13 of the 15 specimens examined. On the enamel side 2 of the 15 specimens showed microleakage. With F2000 and SBMP no micro leakage was observed
on either enamel or dentine sides. The CSLM images show clear resin tag and hybrid layer formation for both the materials examined, although SBMP showed deeper penetration into the dentine with longer resin tags. The length of the resin tags and thickness of the hybrid layer for PBNT was found to be approximately 10 um and 2 um respectively. SBMP showed resin tags measuring about 100 um while the hybrid layer measured about 5 um. Conclusion: This study demonstrates that the acid-etch technique ofSBMP with F2000 produces higher bond strength and no micro leakage when compared to the self-etching/self-priming "non-rinse technique" of NRC with PBNT and Dyract.
|
77 |
Cimentos resinosos endodônticos: selamento apical, aspectos micromorfológicos, características físicas e resistência de união à dentina / Resin-based root canal sealers: apical sealing, micromorphological aspects, physical characteristics and bond strength to dentinSouza, Soráia de Fátima Carvalho 12 December 2007 (has links)
Avaliou-se o selamento apical, os aspectos micromorfológicos da interface adesiva, as características físicas e a resistência de união à dentina de cimentos resinosos endodônticos. Setenta e dois pré-molares humanos unirradiculares foram preparados endodonticamente. Trinta e três dentes foram divididos aleatoriamente em 3 grupos, impermeabilizados externamente e obturados pela técnica da condensação lateral acorde as seguintes condições: AH Plus (AH Plus/Gutapercha); AH Primer (Epiphany primer/AH Plus/Gutapercha) e Epiphany (sistema Epiphany). Foram mantidos a 37oC e 100% de umidade por 72 h e, em seguida, imersos em solução aquosa de nitrato de prata a 50% por 24 h. Após secção longitudinal dos dentes, foram realizadas réplicas em resina epóxica. Réplicas e espécimes foram preparados para MEV. Nas réplicas, observou-se a freqüência de fendas apicais na interface dentina/cimento. Nos espécimes, detectou-se e confirmou-se com EDS (Energy Dispersive Spectroscopy) a microinfiltração apical. A interface dentina/cimento foi observada em seis espécimes de cada grupo, selecionados aleatoriamente. A microinfiltração foi similar entre os grupos (p>0,05), sendo influenciada pela freqüência de fendas (p<0,05). Foram observadas tanto regiões com fendas quanto com camada híbrida e longos tags para o grupo Epiphany. Para os grupos AH Primer e AH Plus foi verificada boa adaptação marginal com longos tags vazios e pequenos plugs, respectivamente, embora tenha ocorrido a formação de fendas em ambos. Os outros dentes foram utilizados para as avaliações adicionais: seis, para complementar o estudo micromorfológico da interface adesiva; três, para o ensaio de microdureza Knoop; e, trinta, para o teste de resistência de união. O cimento Epiphany mostrou maior escoamento (p<0,001) e tensão de polimerização (p<0,05), e a menor resistência de união (p<0,001). Os valores de microdureza Knoop decresceram acentuadamente de cervical para apical (p<0,001). Concluiu-se que a total impermeabilização do sistema de canais radiculares não foi obtida com nenhum dos cimentos testados, e que o sistema Epiphany formou mais fendas no ápice. / Resin-based root canal sealers had their apical sealing, micromorphological aspects, physical characteristics and bond strength to dentin evaluated in this study. For this purpose, seventy-two single-rooted human premolars were endodontically treated. Thirty-three teeth were randomly divided into three groups, externally coated with nail varnish and obturated by lateral condensation technique according to such conditions: AH Plus (AH Plus/Gutta-percha); AH Primer (Epiphany primer/AH Plus/ Gutta-percha) and Epiphany (Epiphany system). They were kept in 100% humidity at 37oC for 72 h, and then the specimens were immersed in 50% aqueous silver nitrate tracer solution for 24 h. The teeth were longitudinally sectioned and their epoxy resin replicas were obtained. Both the specimens and their corresponding replicas were prepared for SEM. In the replicas, the frequency of apical gaps at the dentin/cement interface was observed. In the specimens, the apical microleakage was detected and confirmed by EDS (Energy Dispersive Spectroscopy). The dentin/cement interface was observed in six specimens of each group randomly selected. The microleakage was similar among the groups (p>0,05) being influenced by gaps frequency (p<0,05). The Epiphany group presented gap-containing regions, hybrid layer formation and long tags. For AH Primer and AH Plus groups, good marginal adaptation with long empty tags and small plugs, respectively, although gaps formation was found in both groups. The remaining teeth were used for other evaluations: six, to finish micromorphological study at the adhesive interface; three, for Knoop microhardness; and thirty, for bond strength test. The Epiphany resin sealer has showed the highest flow (p<0.001) and polymerization stress (p<0.05), and the lowest bond strength values (p<0.001). The Knoop microhardness values have decreased excessively from the cervical to the apical third (p<0.001). It was concluded that none of the sealers tested achieved a complete sealing of the root canals system, and the Epiphany system has developed more gaps to the apex.
|
78 |
\"Avaliação da resistência flexural, microinfiltração e grau de conversão de uma resina composta fotoativada com luz halógena e laser de argônio\" / Evaluation of the flexural strenght, microleakage and degree of convertion of a composite resin photocured with argon laser and halogen lamp.Lloret, Patricia Ramos 13 February 2007 (has links)
Nesta pesquisa foi avaliado a resistência flexural, a microinfiltração e o grau de conversão de uma resina composta micro-híbrida fotoativada por laser de argônio e luz halógena. Para o teste de resistência flexural e grau de conversão foram preparadas cinco amostras de 25 X 2 X 2mm de acordo com a norma ISO 4049. Os parâmetros de fotoativação utilizados em todas as etapas do trabalho foram: luz halógena (500mW/cm2) por 20 segudos, laser de argônio (250mW) por 10 e 20 segundos. As amostras foram lixadas com a seqüência de granulações 500, 800, 1000, 1200, 2500 e 4000. Os espécimes eram armazenados em água destilada, em recipiente escuro, em estufa a 37ºC por 24 horas e eram submetidos ao ensaio de resistência flexural (Máquina de Ensaios Mecânicos - Modelo 4411 ? Instron) em velocidade de 1mm/min. Para o estudo da microinfiltração foram utilizados dentes incisivos bovinos (n=20), As cavidades eram preparadas com brocas Carbide #330 com 4mm (altura) X 3mm (largura) X 2mm (profundidade). Os dentes eram então restaurados, e recebiam acabamento e polimento e em seguida eram armazenados em água destilada, em estufa a 37ºC por 24 horas. As amostras foram submetidas ao processo de termociclagem (500 ciclos de 30 segundos - 6ºC e 60ºC). Após a termociclagem, os ápices dos dentes eram selados com IRM e adesivo a base de cianoacrilato e imersos em fucsina básica a 0,5% por 24 horas, em estufa a 37ºC. A análise do grau de conversão foi feita com o Espectrômetro FT-Raman RFS 100/S (Bruker). Para o teste de resistência flexural foi realizado o teste de análise de variância, que mostrou não haver diferença estatisticamente significante entre as fontes fotoativadoras estudadas (p>0,05). A microinfiltração das margens oclusais (em esmalte) e gengivais (em dentina) dos três grupos foram analisadas separadamente por meio do teste de Mann-Whitney. Houve diferença estatisticamente significante ao nível de 5% entre esmalte e dentina, sendo que em todos os grupos a microinfiltração em dentina foi maior que em esmalte. O teste nãoparamétrico Kruskall-Wallis foi utilizado separadamente nas comparações entre as fontes para as análises do grau de microinfiltração em esmalte e dentina. Não houve diferença estatisticamente significante em ambas as comparações, sendo o valor de H= 0,1283 para esmalte e de H=2,3083 para em dentina. Para a análise do grau de conversão foi realizada a análise de variância (ANOVA) entre os grupos. Não houve diferença estatisticamente significante entre as fontes. Diante dos resultados obtidos, pode-se afirmar que o laser de argônio apresentou qualidade de fotoativação semelhante à da luz halógena e que nenhuma fonte ativadora estudada foi capaz de evitar a microinfiltração. / In the research was evaluated the flexural strength, the microleakage and the degree of conversion of a micro-hybrid composite resin photocured with argon laser and halogen lamp. For both flexural test and degree of conversion analysis five bar samples of composite resin (25 X 2 X 2mm) were prepared and polymerized following the ISO 4049. The light cured unit halogen was used with 500mW/cm2 for 20 seconds and the argon laser with 250mW for 10 and 20 seconds. After curing, samples were removed from the molds, polished using silicon carbide paper up to 4000 grit-number and stored in distilled water in dark environment at 37oC for 24 hours. The flexural property was quantified by a three-point loading test (Model 4411, Instron Corp., Canton, MA) with a cross-head speed of 1,0mm/min. To microleakage test sixty bovine incisors were used to prepare standardized class V cavities that were restored and polished. The specimens were stored in water for 24 hours at 37oC and thermocycled 500 times between water baths kept at 5 oC and 55 oC. After thermocycling, specimens were immersed in a aqueous solution of basic fuchsin for 24 hours. Longitudinal sections of each restoration were obtained and examined with a stereomicroscope for qualitive evaluation of microleakage. FTRaman RFS 100/S spectrometer (Bruker) was used to analyse the degree of conversion. The ANOVA test showed that there were no statistically significant difference of the flexural setrength between the photo-activation types evaluated in the flexural study. Microleakage data was statistically analysed by Mann-Whitney and Kruskall-Wallis tests. Enamel margins resulted in statistical lower degree of leakage than dentin margins. There was no statistically significant difference between the three types of photo-curing studied. The ANOVA test also showed that there were no statistically significant difference of the degree of conversion between the studied groups. According to the methodology used in this research it was concluded that the argon laser is a posible alternative for photocuring, providing the same quality of polymerization as do the halogen lamp. None of the photocured units tested in this study completely eliminated microleakage.
|
79 |
Cimentos resinosos endodônticos: selamento apical, aspectos micromorfológicos, características físicas e resistência de união à dentina / Resin-based root canal sealers: apical sealing, micromorphological aspects, physical characteristics and bond strength to dentinSoráia de Fátima Carvalho Souza 12 December 2007 (has links)
Avaliou-se o selamento apical, os aspectos micromorfológicos da interface adesiva, as características físicas e a resistência de união à dentina de cimentos resinosos endodônticos. Setenta e dois pré-molares humanos unirradiculares foram preparados endodonticamente. Trinta e três dentes foram divididos aleatoriamente em 3 grupos, impermeabilizados externamente e obturados pela técnica da condensação lateral acorde as seguintes condições: AH Plus (AH Plus/Gutapercha); AH Primer (Epiphany primer/AH Plus/Gutapercha) e Epiphany (sistema Epiphany). Foram mantidos a 37oC e 100% de umidade por 72 h e, em seguida, imersos em solução aquosa de nitrato de prata a 50% por 24 h. Após secção longitudinal dos dentes, foram realizadas réplicas em resina epóxica. Réplicas e espécimes foram preparados para MEV. Nas réplicas, observou-se a freqüência de fendas apicais na interface dentina/cimento. Nos espécimes, detectou-se e confirmou-se com EDS (Energy Dispersive Spectroscopy) a microinfiltração apical. A interface dentina/cimento foi observada em seis espécimes de cada grupo, selecionados aleatoriamente. A microinfiltração foi similar entre os grupos (p>0,05), sendo influenciada pela freqüência de fendas (p<0,05). Foram observadas tanto regiões com fendas quanto com camada híbrida e longos tags para o grupo Epiphany. Para os grupos AH Primer e AH Plus foi verificada boa adaptação marginal com longos tags vazios e pequenos plugs, respectivamente, embora tenha ocorrido a formação de fendas em ambos. Os outros dentes foram utilizados para as avaliações adicionais: seis, para complementar o estudo micromorfológico da interface adesiva; três, para o ensaio de microdureza Knoop; e, trinta, para o teste de resistência de união. O cimento Epiphany mostrou maior escoamento (p<0,001) e tensão de polimerização (p<0,05), e a menor resistência de união (p<0,001). Os valores de microdureza Knoop decresceram acentuadamente de cervical para apical (p<0,001). Concluiu-se que a total impermeabilização do sistema de canais radiculares não foi obtida com nenhum dos cimentos testados, e que o sistema Epiphany formou mais fendas no ápice. / Resin-based root canal sealers had their apical sealing, micromorphological aspects, physical characteristics and bond strength to dentin evaluated in this study. For this purpose, seventy-two single-rooted human premolars were endodontically treated. Thirty-three teeth were randomly divided into three groups, externally coated with nail varnish and obturated by lateral condensation technique according to such conditions: AH Plus (AH Plus/Gutta-percha); AH Primer (Epiphany primer/AH Plus/ Gutta-percha) and Epiphany (Epiphany system). They were kept in 100% humidity at 37oC for 72 h, and then the specimens were immersed in 50% aqueous silver nitrate tracer solution for 24 h. The teeth were longitudinally sectioned and their epoxy resin replicas were obtained. Both the specimens and their corresponding replicas were prepared for SEM. In the replicas, the frequency of apical gaps at the dentin/cement interface was observed. In the specimens, the apical microleakage was detected and confirmed by EDS (Energy Dispersive Spectroscopy). The dentin/cement interface was observed in six specimens of each group randomly selected. The microleakage was similar among the groups (p>0,05) being influenced by gaps frequency (p<0,05). The Epiphany group presented gap-containing regions, hybrid layer formation and long tags. For AH Primer and AH Plus groups, good marginal adaptation with long empty tags and small plugs, respectively, although gaps formation was found in both groups. The remaining teeth were used for other evaluations: six, to finish micromorphological study at the adhesive interface; three, for Knoop microhardness; and thirty, for bond strength test. The Epiphany resin sealer has showed the highest flow (p<0.001) and polymerization stress (p<0.05), and the lowest bond strength values (p<0.001). The Knoop microhardness values have decreased excessively from the cervical to the apical third (p<0.001). It was concluded that none of the sealers tested achieved a complete sealing of the root canals system, and the Epiphany system has developed more gaps to the apex.
|
80 |
\"Avaliação da resistência flexural, microinfiltração e grau de conversão de uma resina composta fotoativada com luz halógena e laser de argônio\" / Evaluation of the flexural strenght, microleakage and degree of convertion of a composite resin photocured with argon laser and halogen lamp.Patricia Ramos Lloret 13 February 2007 (has links)
Nesta pesquisa foi avaliado a resistência flexural, a microinfiltração e o grau de conversão de uma resina composta micro-híbrida fotoativada por laser de argônio e luz halógena. Para o teste de resistência flexural e grau de conversão foram preparadas cinco amostras de 25 X 2 X 2mm de acordo com a norma ISO 4049. Os parâmetros de fotoativação utilizados em todas as etapas do trabalho foram: luz halógena (500mW/cm2) por 20 segudos, laser de argônio (250mW) por 10 e 20 segundos. As amostras foram lixadas com a seqüência de granulações 500, 800, 1000, 1200, 2500 e 4000. Os espécimes eram armazenados em água destilada, em recipiente escuro, em estufa a 37ºC por 24 horas e eram submetidos ao ensaio de resistência flexural (Máquina de Ensaios Mecânicos - Modelo 4411 ? Instron) em velocidade de 1mm/min. Para o estudo da microinfiltração foram utilizados dentes incisivos bovinos (n=20), As cavidades eram preparadas com brocas Carbide #330 com 4mm (altura) X 3mm (largura) X 2mm (profundidade). Os dentes eram então restaurados, e recebiam acabamento e polimento e em seguida eram armazenados em água destilada, em estufa a 37ºC por 24 horas. As amostras foram submetidas ao processo de termociclagem (500 ciclos de 30 segundos - 6ºC e 60ºC). Após a termociclagem, os ápices dos dentes eram selados com IRM e adesivo a base de cianoacrilato e imersos em fucsina básica a 0,5% por 24 horas, em estufa a 37ºC. A análise do grau de conversão foi feita com o Espectrômetro FT-Raman RFS 100/S (Bruker). Para o teste de resistência flexural foi realizado o teste de análise de variância, que mostrou não haver diferença estatisticamente significante entre as fontes fotoativadoras estudadas (p>0,05). A microinfiltração das margens oclusais (em esmalte) e gengivais (em dentina) dos três grupos foram analisadas separadamente por meio do teste de Mann-Whitney. Houve diferença estatisticamente significante ao nível de 5% entre esmalte e dentina, sendo que em todos os grupos a microinfiltração em dentina foi maior que em esmalte. O teste nãoparamétrico Kruskall-Wallis foi utilizado separadamente nas comparações entre as fontes para as análises do grau de microinfiltração em esmalte e dentina. Não houve diferença estatisticamente significante em ambas as comparações, sendo o valor de H= 0,1283 para esmalte e de H=2,3083 para em dentina. Para a análise do grau de conversão foi realizada a análise de variância (ANOVA) entre os grupos. Não houve diferença estatisticamente significante entre as fontes. Diante dos resultados obtidos, pode-se afirmar que o laser de argônio apresentou qualidade de fotoativação semelhante à da luz halógena e que nenhuma fonte ativadora estudada foi capaz de evitar a microinfiltração. / In the research was evaluated the flexural strength, the microleakage and the degree of conversion of a micro-hybrid composite resin photocured with argon laser and halogen lamp. For both flexural test and degree of conversion analysis five bar samples of composite resin (25 X 2 X 2mm) were prepared and polymerized following the ISO 4049. The light cured unit halogen was used with 500mW/cm2 for 20 seconds and the argon laser with 250mW for 10 and 20 seconds. After curing, samples were removed from the molds, polished using silicon carbide paper up to 4000 grit-number and stored in distilled water in dark environment at 37oC for 24 hours. The flexural property was quantified by a three-point loading test (Model 4411, Instron Corp., Canton, MA) with a cross-head speed of 1,0mm/min. To microleakage test sixty bovine incisors were used to prepare standardized class V cavities that were restored and polished. The specimens were stored in water for 24 hours at 37oC and thermocycled 500 times between water baths kept at 5 oC and 55 oC. After thermocycling, specimens were immersed in a aqueous solution of basic fuchsin for 24 hours. Longitudinal sections of each restoration were obtained and examined with a stereomicroscope for qualitive evaluation of microleakage. FTRaman RFS 100/S spectrometer (Bruker) was used to analyse the degree of conversion. The ANOVA test showed that there were no statistically significant difference of the flexural setrength between the photo-activation types evaluated in the flexural study. Microleakage data was statistically analysed by Mann-Whitney and Kruskall-Wallis tests. Enamel margins resulted in statistical lower degree of leakage than dentin margins. There was no statistically significant difference between the three types of photo-curing studied. The ANOVA test also showed that there were no statistically significant difference of the degree of conversion between the studied groups. According to the methodology used in this research it was concluded that the argon laser is a posible alternative for photocuring, providing the same quality of polymerization as do the halogen lamp. None of the photocured units tested in this study completely eliminated microleakage.
|
Page generated in 0.0467 seconds