• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • Tagged with
  • 66
  • 46
  • 40
  • 38
  • 37
  • 27
  • 26
  • 26
  • 24
  • 23
  • 19
  • 19
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação in vitro da microtração de sistemas adesivos à dentina irrigada com soluções endodônticas: Influência da degradação da interface adesiva / In vitro evaluation of systems on microtensile bond strength to orrogated dentin with endodontic solutions. Adhesive interface degradation influence

Daniel Galafassi 27 January 2009 (has links)
O objetivo desse trabalho foi avaliar a influência da resistência de união de sistemas adesivos à dentina irrigada com substâncias endondônticas, após a degradação da interface adesiva e análise morfológica da interface adesiva por meio de microscopia eletrônica de varredura (MEV). Foram selecionados sessenta terceiros molares, que tiveram a porção oclusal removida e planificada expondo a dentina profunda. Os espécimes foram irrigados com hipoclorito de sódio a 2,5% por 30 minutos e em seguida em EDTA 17% por 5 minutos. Após a irrigação da superfície detinária os dentes foram divididos aleatoriamente em seis grupos (n = 10) de acordo com o sistema adesivo empregado: G1 e G2 - Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). Após a aplicação do sistema adesivo, foi confeccionado um platô de resina composta Z100 (3M). A degradação da interface adesiva foi realizada por meio de estocagem em água deionizada/ciclagem térmica: 24 horas de estocagem em água deionizada/nenhum ciclo (grupos G1, G3 e G5) e 6 meses de estocagem em água deionizada/12.000 ciclos (grupos G2, G4 e G6). Após os períodos pré-estabelecidos em cada grupo, os conjuntos dente/resina foram seccionados de forma a se obter 4 palitos de aproximadamente de 1mm2, que foram submetidos ao teste de microtração. A análise morfológica da interface foi realizada por meio de MEV. Os dados obtidos foram submetidos a ANOVA e teste de Tukey ao nível de 5%. Verificou-se que houve diferença significativa entre os adesivos (p<0,01). A durabilidade da adesão da resina composta a dentina irrigada com solução endodôntica não foi afetada após 6 meses de estocagem em água e 12.000 ciclos térmicos (p<0,05). A análise da interface adesiva evidenciou que os sistemas adesivos não alteraram o padrão de união mesmo após 6 meses de ciclagem térmica e degradação em água, exceto para o sistema adesivo XP Bond. Pode-se concluir que a dentina irrigada com NaOCl e EDTA apresentou menor resistência a microtração quando do emprego do sistema adesivo XP Bond. A degradação da interface por meio do armazenamento em água e ciclagem térmica não influenciou na resistência de união, independente do sistema adesivo empregado. / The aim of the present study was to survey the influence of endodontic irrigants on the adhesion resistance of adhesive systems to human dentin, after the degradation of adhesive interface and morphologic analysis of adhesive interface for Scanning Electronic Microscopy SEM. Sixty molar thirds were selected. The deep dentin was exposed removing and ground the oclusal portion. The specimens were irrigated with sodium hypochlorite 2,5% for 30 minutes followed by EDTA 17% for 5 minutes. Subsequently, teeth were divided randomly in six groups (n=10) accordingly to adhesive system applied: G1 and G2 Clearfil (Kuraray); G3 e G4 - Single Bond 2 (3M) e G5 e G6 - XP Bond (Dentsply). After adhesive system application, a composite resin Z100 (3M) was built up created. The degradation of the adhesive interface was realized by storage the specimens in deionized water and thermocycling: 24 hours of deionized water storage/no cycle (groups G1, G3 and G5) and 6 months storage in deionized water/12.000 cycles (groups G2, G4 and G6). After pre-established periods of each group, the systems tooth/resin were sectioned in order to obtain 4 sticks of approximately 1mm2, which were subjected to microtensile bond strength test. The morphologic analysis of interface was performed for SEM. Results were analyzed with ANOVA and Tukey test to level 5%. Significant difference between adhesives was verified (p<0,01). The water storage (6 months) coupled with thermocycling (12.000 cycles) did not affected significantly the resistance to microtensile bond strength of the dentin (p<0,05). The conclusion is that dentin irrigated with NaOCl and EDTA presented less resistance to microtensile bond strength when XP Bond Adhesive system was utilized. The interface degradation through water storage and thermocycling had no effect on the resistance of the dentin bond, independently of the adhesive system applied.
22

Avaliação da eficiência de adesão de um cimento resinoso autocondicionante (self-adhesive) sobre esmalte e dentina: efeito termociclagem e condicionamento dental : estudo in vitro

Fernandes Júnior, Virgílio Vilas Boas [UNESP] 27 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-27Bitstream added on 2014-06-13T20:51:27Z : No. of bitstreams: 1 fernandesjunior_vvb_me_sjc.pdf: 534033 bytes, checksum: dc3fecf909acf51fb45b0235288dbddc (MD5) / O objetivo do trabalho foi analisar in vitro a eficiência de adesão através de ensaio de microtração, de um cimento autocondicionante (self-adhesive), sobre esmalte e dentina, com e sem tratamento prévio da superfície dental, antes e após termociclagem. Foram utilizados 56 terceiros molares, 28 para esmalte e 28 para dentina, divididos em 6 grupos experimentais e 2 controle. O cimento resinoso autocondicionante selecionado para os grupos experimentais foi: Rely-X Unicem (3M ESPE/ St. Paul, MN, EUA), e para os grupos controle o Variolink II (Ivoclar Vivadent, AG, Schaan, Liechtenstein) (VR), cimento de cura dual não autocondicionante. Os dentes dos grupos experimentais foram subdivididos quanto à aplicação direta do cimento sobre a superfície dental (R), com o condicionamento ácido (RAC) e com condicionamento ácido e aplicação de sistema adesivo (RACAS). Blocos de resina composta previamente polimerizados foram cimentados à superfície dental. Os conjuntos dente-cimento-bloco receberam cortes paralelos ao longo eixo dos dentes para a confecção dos palitos. O ensaio de microtração com aparelho de ensaio universal (EMIC) foi utilizado para analisar a resistência adesiva dos cimentos avaliados. Os corpos de prova após o ensaio foram analisados mediante microscópio óptico para analise do modo de fratura. Para a análise estatística do μTBST, foi utilizado ANOVA 3 fatores com teste de comparação múltipla de Tukey a 5%, considerando os fatores cimento resinoso, região e armazenagem. Os resultados mostraram diferença estatística existente entre R aplicado diretamente sobre a superfície dental e os demais grupos. Os grupos RACAS e VR apresentaram maiores médias de resistência adesiva para os grupos dentina, respectivamente antes e após termociclagem e o cimento RAC para os grupos esmalte. A termociclagem não diminuiu significativamente os valores de resistência... / The objective of this research was to analyze in vitro , the adhesive efficiency of a self - etching cement trough microtensile test , over enamel and dentine , with and with out previous treatment of dental surface , before and after thermocycling. Were used 56 third molars, 28 for enamel and 28 for dentine, divided in 06 experimental groups and 02 control groups. The resin cement self - etching selected for the experimental groups was: Rely X Unicem (3M ESPE/ St. Paul, MN, EUA), and for the control groups: Variolink II (Ivoclar Vivadent, AG, Schaan , Liechtenstein) (VR), dual healing cement not self etching. The teeth of the experimental groups were subdivided in groups as the direct application of cement over the dental surface (R) without previous treatment (RAC), with the acid etching and with acid etching and application of adhesive system (RACAS) e (VR). Composed resin blocks polymerized previously were cemented on dental surface. The sets tooth- cement-block received parallel cuts in long axis of the teeth to make the tooth picks. The micro tensile test was done with the universal apparatus (EMIC) to analyze the resistance efficiency of the evaluated cements. The specimens were analyzed after the test by optical microscope to analyze the mode fracture. For the statistics analyses of μTBST, were used ANOVA 3 factors with multiple comparison test of Tukey 5%, considering the factors resin cement, region and storage. The results showed present statistics difference between R applied directly on dental surface and the other groups. The groups RACAS and VR presented superior average of adhesive resistance for dentine groups before and after thermocycling, and the RAC cement for the enamel groups before and after thermocycling. The thermocycling did not low significantly the adhesive resistance values, just for the RACAS group. By the results we can conclude that the self etching... (Complete abstract click electronic access below)
23

A influência do corte com diferentes discos e velocidades na integridade dos espécimes e na resistência adesiva de uma cerâmica a um cimento resinoso dual em ensaio de microtração / The influence of different cutting speeds and brand of diamond saws on integrity of microtensile specimes and Bond strenght values

Martha Chiabai Cupertino de Castro 19 November 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta pesquisa estudou a influência de diferentes velocidades de corte e marcas de discos diamantados nos valores de resistência adesiva, durante a preparação dos espécimes a serem submetidos à microtração, e na integridade das amostras por meio do microscópio eletrônico de varredura (MEV). Vinte blocos da cerâmica à base de dissilicato de lítio (IPS e.max Press) foram unidos com cimento resinoso (Rely X ARC) a blocos de compósito (Z100), construídos incrementalmente. Foram seguidas as recomendações dos fabricantes no tratamento da superfície da cerâmica e aplicação do cimento resinoso. Após 24 horas em água destilada a 37C, os espécimes foram divididos em dois grupos de discos: marcas Buehler e Extec e subdivididos nas velocidades de 200rpm e 400rpm (B2; E2; B4 e E4, respectivamente). Cada espécime foi cortado em dois eixos perpendiculares para obtenção de palitos com área adesiva de 1,0mm. Para cada condição experimental, os palitos foram separados, aleatoriamente, 15 palitos para análise ao MEV e 30 palitos para serem submetidos à força de tração. As médias de resistência adesiva em MPa foram E4=20,312 ; B4= 24,2 11,3 ; B2= 25,2 9,0 e E2= 28,6 10,4. Na análise estatística, observou-se que os valores de resistência adesiva na velocidade de 200rpm foram significativamente maiores comparados a velocidade de 400rpm, independente do disco empregado. Ao MEV, observou-se melhor integridade dos palitos na velocidade de 200rpm com presença de trincas menos extensas nas bordas externas. Constatou-se também que o disco Extec na velocidade de 400rpm apresentou movimentos excêntricos ao corte e obteve-se maior número de perdas prematuras, uma diminuição significante na média da área total de união (p<0,05), além de diferença significativa nos valores de resistência comparada a velocidade de 200rpm. Concluiu-se que a utilização de diferentes velocidades e sua interação com o disco empregado interfere na integridade dos espécimes e nos valores de resistência adesiva, sendo mais acentuada ao se utilizar o disco da marca Extec. / The aim of this research was to verify the influence of different cutting speeds and brand of diamond saws during microtensile specimen preparation on the bonding strength values and on the samples microscopy integrity (SEM). Twenty lithium disilicate glass-ceramic blocks (IPS e.max Press) were bonded with dual-cure resin cement (Rely X ARCTM) to composite (Z100TM) blocks, built incrementally. The manufacturers recommendations were followed for ceramic treatment surface and placement on the resin cement, as well. After storage for 24 hours in distillated water at 37C, the specimens were divided in two groups of diamond saws, Buehler and Extec brands, which were further subdivided using 200rpm and 400rpm speeds (B2; E2; B4 and E4 respectively), and they were sectioned into two perpendicular axes obtaining sticks shaped specimens with cross-sectional area of 1.0mm. For each experimental situation the sticks were randomly separated; 15 for the analysis to the SEM and 30 to be submitted to tensile strength. Mean bond strength values (MPa) were: E4 = 20.3 12; B4 = 24.2 11.3; B2 = 25.2 9.0; and E2 = 28.6 10.4. The statistical analysis of data showed that the values of bond strength at 200 rpm speed were significantly higher as compared to 400 rpm speed, regardless of saw employed. In SEM, it was noted better integrity of sticks at 200 rpm speed with presence of less extensive cracks in external edges. It was also found that the Extec saw at 400 rpm showed eccentric movement to cutting and achieved higher number of premature losses, a significant decreased mean total area of bond (p<0.05), in addition to significant difference in strength values compared with 200 rpm speed. It was concluded that using different speeds and their interaction with the used saw interfere with the integrity of specimens and the bond strength values, being more pronounced when using the Extec saw.
24

Influência do selamento imediato da dentina na resistência de união de diferentes sistemas adesivos junto a cimentações de restaurações indiretas / Influence of immediate dentin sealing on bond strength of different adhesive systems on the cementation of indirect restorations

Rafael Barroso Pazinatto 30 September 2010 (has links)
Hipótese do estudo: A presente pesquisa hipotetiza que a técnica de cimentação está diretamente ligada a resistência adesiva de restaurações indiretas. Objetivos: O presente estudo experimental verificou se o selamento imediato da dentina, com diferentes sistemas adesivos, apresentaram melhores resultados de resistência de união junto a cimentação resinosa de restaurações indiretas. Métodos: Foram utilizados 48 terceiros molares humanos, divididos em seis grupos de acordo com as técnicas de cimentação testadas: grupo 1) Sistema Variolink II (Ivoclar Vivadent); grupo 2) Clearfill SE (Kuraray) + Variolink II; grupo 3) Selamento com Clearfill SE + Sistema Variolink II após 24h; grupo 4) Selamento com Exite DSC (Ivoclar Vivadent) + Sistema Variolink II; grupo 5) Selamento com Clearfill + Tetric Evo Flow (Ivoclar Vivadent) + Sistema Variolink II após 24h; Grupo 6) selamento com Exite DSC + Tetric Evo Flow + Sistema Variolink II após 24h. Oito amostras de cada grupo foram para máquina de cortes seriados (Isomet 1000) para obtenção de palitos com 1mm2 de área. Os palitos de cada grupo foram submetidos ao teste de microtração. O teste de microtração foi utilizado após 24h da cimentação. Os dados foram estatisticamente analisados pelo teste de Kruskal-Wallis e o teste de Dunn (5%). Diferenças significativas foram detectadas (p=0,0074). Resultados: Os grupos 1 e 2 apresentaram mediana de resistência de união intermediária, sendo estatisticamente semelhantes aos demais grupos. O grupo 6 apresentou mediana significativamente mais alta que os grupos 3, 4 e 5, os quais foram semelhantes entre si. Adicionalmente os tipos de fratura foram analisados com auxílio de lupa estereoscópica, em todos os grupos a porcentagem de fraturascoresivas em dentina ou mistas foi menor em comparação as fraturas adesivas e coesivas em cerômeros. Conclusão: O selamento imediato da dentina com adesivo de condicionamento total junto a resina flow demonstrou maior resistência adesiva. / Hypothesis of the study: This study hypothesizes that the cementation technique is directly related to the bond strength of indirect restorations. Objectives: The present experimental study examined whether the immediate dentin sealing with different bonding systems, the best-performing bond strength in the resin cementation of indirect restorations. Methods: A total of 48 human third molars was divided into six groups according to the techniques of tested: group 1) Variolink System II (Ivoclar Vivadent), group 2) Clearfill SE (Kuraray) + Variolink II, Group 3) with Seal Clearfill SE + System Variolink II after 24h, group 4) Sealing successfully DSC (Ivoclar Vivadent) + Variolink System II, Group 5) Sealing with Clearfill + Tetric Evo Flow (Ivoclar Vivadent) + System Variolink II after 24h, Group 6) sealing successfully DSC + + Tetric Evo Flow System Variolink II after 24h. Eight samples of each group were machine serial sections (Isomet 1000) to obtain sticks with 1 mm2 in size. The sticks of each group were subjected to microtensile testing. The microtensile test was performed used after 24h of cementation. The data were statistically analyzed by Kruskal- Wallis test and Dunn (5%). Significant differences were detected (p = 0.0074). Results: Groups 1 and 2 had a median of intermediate bond strength, being statistically similar to other groups. The sixth group median significantly higher than groups 3, 4 and 5, which were similar. Besides the types of fracture were analyzed with the aid of a stereomicroscope. Conclusions: The immediate detin sealing with total etch adhesive and the flowable resin showed higher bond strength.
25

Efeito do ascorbato de sódio 10% na resistência adesiva de resina composta em esmalte clareado após o envelhecimento

Lima, Thiago Mendes de 21 February 2014 (has links)
Made available in DSpace on 2015-04-11T13:55:49Z (GMT). No. of bitstreams: 1 Thiago Mendes de Lima.pdf: 1095985 bytes, checksum: af3d342d9c71734320c0b651931b5083 (MD5) Previous issue date: 2014-02-21 / Fundação de Amparo à Pesquisa do Estado do Amazonas / A utilização de agentes antioxidantes tem sido proposta para melhorar a resistência adesiva após clareamento dental. O presente estudo in vitro avaliou o efeito do hidrogel de ascorbato de sódio a 10% (AS), aplicado após o clareamento com peróxido de hidrogênio a 35% (PH), na resistência adesiva em esmalte de uma resina composta (RC). Foram selecionados 50 dentes bovinos e aleatoriamente divididos em cinco grupos experimentais (n=10) subdividindo-os em grupos testados tardiamente (7 dias) e após envelhecimento (3 meses): Grupo 1 (G1: 7 dias/ G1A: 3 meses) - sem clareamento (grupo controle) + RC; G2/G2A PH + RC; G3/G3A PH + 14 dias + RC; G4/G4A PH 35% + AS 10% (30 min) + RC; G5/G5A PH + 14 dias + AS (30 min) + RC. Foram obtidos palitos de resina-adesivo-esmalte (1mm x1mm) e submetidos ao tese de resistência à microtração em uma máquina de ensaio universal EMIC DL2000 (100N a 0,5mm/min). Os tipos de falhas foram analisados em microscopia digital (40x) e eletrônica de varredura, classificado-as como coesiva, adesiva, mista. Os valores (Mpa) de resistência adesiva à microtração foram avaliados estatisticamente através da Análise de Variância a dois critérios (ANOVA) e do teste de Tukey para comparações das médias, com significância 1%. Os resultados foram: G1: 20,09Aab ± 5,33 / G1A: 24,09Abc ± 5,12; G2: 17,14Aa ± 4,94 / G2A: 20,84Aab ± 5,21; G3: 20,36Aab ± 5,30 / G3A: 22,76Abc ± 5,40; G4: 22,18Aabc ± 5,30 / G4A: 30,22Ad ± 8,05; G5: 21,92Aab ± 5,90 / G5A: 27,25Ac ± 7,12. Pode-se concluir que, o uso do ascorbato de sódio a 10% interfere positivamente na resistência adesiva de restaurações envelhecidas em 3 meses, aumentando os valores de resistência adesiva.
26

"Resistência de união, ao ensaio de microtração, de selante e sistemas adesivos aplicados em superfícies oclusais de molares decíduos" / Micro-tensile bond strength of sealant and adhesive systems applied on occlusal surfaces of primary molars.

Ana Cláudia Durante Ramires-Romito 31 March 2005 (has links)
O objetivo deste estudo foi avaliar a resistência de união, ao ensaio de microtração, de selante (Clinpro, 3M) e sistemas adesivos (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) aplicados em superfícies oclusais de molares decíduos (n=32). Os produtos avaliados foram testados após serem aplicados de acordo com as recomendações dos fabricantes e após contaminação da superfície oclusal com saliva. Após armazenagem em água por 24h a 37ºC, cada dente foi secionado no plano mésio-distal e perpendicularmente à interface de união para obtenção de corpos-de-prova em forma de palito com seção transversal retangular e área aproximada de 0,6 mm 2 . Cada corpo-de-prova foi submetido ao teste de tração em máquina de ensaio universal a uma velocidade de 0,5 mm/min e os fragmentos armazenados para análise posterior do padrão de fratura em microscopia eletrônica de varredura. As fraturas foram classificadas em: adesiva mista, tipo 1 (fratura tanto de material restaurador, isto é associação de adesivo/resina composta, como do esmalte e o substrato predominante foi esmalte); adesiva mista, tipo 2 (fratura tanto de material restaurador como do esmalte e o substrato predominante foi o material restaurador); adesiva mista, tipo 3 (fratura tanto de material restaurador como do esmalte e houve distribuição homogênea de ambos); mista tipo 4 (fratura apenas de material restaurador, isto é, adesivo associado à resina composta) e; coesiva tipo 5 (fratura coesiva exclusivamente de um do substratos sendo esmalte ou resina composta). A análise estatística dos dados obtidos, relativos à resistência de união, usou como unidade experimental o dente. Os palitos perdidos em cada grupo foram incluídos no cálculo de resistência de cada dente. A contaminação salivar não influe nciou a perda de palitos. Não houve associação entre o padrão de fratura e os valores de resistência de união. As fraturas foram predominantemente mistas, não foi observada fratura coesiva exclusivamente de esmalte ou resina composta. Para os sistemas adesivos testados, nenhuma diferença significante foi observada entre os grupos com contaminação salivar ou não. OptiBond FL (34,5 ± 2,2 MPa) e Clinpro (45,1 ± 3,2 MPa) apresentaram valores de resistência de união similares e significativamente maiores do que o OptiBond Solo Plus (19,1 ± 2,3 MPa) e OptiBond Solo SE (9,8 ± 2,3 MPa) que foram equivalentes entre eles (p > 0,05). / The aim of this study was to evaluate the micro-tensile bond strength (mTBS) of a conventional sealant (Clinpro, 3M) and adhesive systems (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) on occlusal surface of primary molars (n=32). Sealant and adhesives were tested under manufacturers’ specifications and after contamination of the bonding site with saliva. After storage in distilled water at 37 º C for 24 h, the specimens were longitudinally sectioned perpendicular to the adhesive interface. Stick shape samples with cross-sectional areas of about 0.6 mm 2 were obtained and subjected to a tensile force in a universal testing machine at a crosshead speed of 0.5 mm/min. The bond failure modes were evaluated at scanning electron microscope and classified as following: mixed, type 1 (with cohesive failure of the neighboring substrates, wherein enamel was predominant); mixed, type 2 (with cohesive failure of the neighboring substrates, wherein adhesive/resin composite was predominant); mixed, type 3 (with cohesive failure of the neighboring substrates, wherein enamel and adhesive/resin composite was equally distributed); mixed, type 4 (with cohesive failure of the neighboring substrates, where there was only adhesive and resin composite, with none enamel fracture); cohesive, type 5 (failure exclusive within enamel or resin composite). The mean value of bond strength was calculated for each of the four teeth used per group, meaning that the experimental unit was the tooth. These were averaged to express the mean bond strength for every material at each group. The specimens lost due to pre-testing failure were included in the calculus of the mTBS of each tooth. Moisture did not influence sticks loss. There was not any association between failure mode and values of mTBS. The majority of fractures were mixed, none cohesive failure of enamel or composite resin was observed. For the tested adhesive systems no significant difference was observed between the groups under either saliva contamination or not. OptiBond FL (34.5 ± 2.2 MPa) and Clinpro (45.1 ± 3.2 MPa) showed similar values of mTBS and significantly higher than OptiBond Solo Plus (19.1 ± 2.3 MPa) and OptiBond Solo SE (9.8 ± 2.3 MPa) that were equivalent to each other (p>0.05).
27

Avaliação da influência do tratamento térmico do silano sobre a resistência de união entre cimentos resinosos e uma cerâmica feldspática

Carvalho, Ronaldo Luís Almeida de 24 January 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-03-22T17:35:14Z No. of bitstreams: 1 ronaldoluisalmeidadecarvalho.pdf: 1029602 bytes, checksum: cc60051c61c4c956fd0881bb40822c3c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T02:26:37Z (GMT) No. of bitstreams: 1 ronaldoluisalmeidadecarvalho.pdf: 1029602 bytes, checksum: cc60051c61c4c956fd0881bb40822c3c (MD5) / Made available in DSpace on 2016-04-24T02:26:37Z (GMT). No. of bitstreams: 1 ronaldoluisalmeidadecarvalho.pdf: 1029602 bytes, checksum: cc60051c61c4c956fd0881bb40822c3c (MD5) Previous issue date: 2013-01-24 / O objetivo do presente estudo foi avaliar três hipóteses: H0- O tratamento térmico do silano e o tipo de cimento resinoso não influencia na resistência de união entre cimentos resinosos e uma cerâmica feldspática; H1- O tratamento térmico do silano influencia na resistência de união entre cimentos resinosos e uma cerâmica feldspática; H2- O cimento resinoso influencia na resistência de união de uma cerâmica feldspática. Foram confeccionados 30 blocos cerâmicos (VITA Mark II, Zahnfabrik), os quais foram duplicados em resina composta (W3D Master, Wilcos). Os blocos foram divididos em 6 grupos (n=5) de acordo com os seguintes tratamentos de superfície: ASCp- Ácido fluorídrico 10% + silano + Panavia F; ASTCp- Ácido fluorídrico 10% + silano + tratamento térmico (forno) + Panavia F; STCp- Silano + tratamento térmico (forno) + Panavia F; ASCr- Ácido fluorídrico 10% + silano + RelyX ARC; ASTCr- Ácido fluorídrico 10% + silano + tratamento térmico (forno) + RelyX ARC; STCr- Silano + tratamento térmico (forno) + RelyX ARC. Para realização do tratamento térmico do silano foi utilizado forno sob temperatura de 100 ºC durante 2 minutos. Cada bloco cerâmico já condicionado foi unido ao seu correspondente em resina composta, utilizando o cimento resinoso respectivo ao seu grupo, sob a carga constante de 750g. Cada conjunto cerâmica/cimento/resina composta foi seccionado e os corpos de prova foram analisados por meio do teste mecânico de microtração. Os valores de resistência de união e os desvios-padrão (MPa) para os grupos foram: ASCp (25,47 ± 9,34a); ASTCp (33,04 ± 10,65b); STCp (13,76 ± 8,82c); ASCr (24,80 ± 7,99a); ASTCr (23,84 ± 7,16a); STCr (11,41 ± 11,71c). Os testes ANOVA e Post Hoc foram aplicados. Com os resultados deste estudo, pode-se concluir: A hipótese H0 foi rejeitada; A hipótese H1 foi parcialmente aceita, pois o tratamento térmico do silano proporcionou maiores valores médios de resistência de união desde que seja realizado em associação com o condicionamento com ácido fluorídrico a 10%, independente do cimento resinoso testado; A hipótese H2 foi parcialmente aceita, pois o cimento com MDP apresentou valor médio de resistência de união estatisticamente superior ao cimento convencional, quando foi realizado o condicionamento com ácido fluorídrico a 10% previamente ao tratamento térmico do silano. / The aim of this study was to evaluate three hypotheses: H0- Heat treatment of silane and resin cement type does not influence the bond strength of resin cements and a feldspathic ceramic;H1- Heat treatment of silane influences the bond strength between cements resin and a feldspathic ceramic; H2- The resin cement influences the bond strength of a feldspathic ceramic. Thirty blocks were fabricated using a ceramic (VITA Mark II, Zahnfabrik), which were duplicated in composite resin (W3D Master, Wilcos). The blocks were divided into 6 groups (n = 5) in accordance with the following surface treatments: ASCp- Hydrofluoric acid 10% + silane + Panavia F; ASTCp- Hydrofluoric acid 10% + silane + heat treatment (furnace) + Panavia F; STCp- Silane + heat treatment (furnace) + Panavia F; ASCr- Hydrofluoric acid 10% + silane + RelyX ARC; ASTCr- Hydrofluoric acid 10% + silane + heat treatment (furnace) + RelyX ARC; STCr- Silane + heat treatment (furnace) + RelyX ARC. To perform the heat treatment silane was used furnace under temperature of 100 ° C for 2 minutes. Then each ceramic block conditioning was already attached to its corresponding composite resin, using a resin cement to its respective group, under the constant load of 750g. Each set ceramic / cement / composite resin was sectioned and the specimens were analyzed by microtensile mechanical test. The bond strength values and standard deviations (MPa) for the groups were: ASCp (25.47 ± 9.34a); ASTCp (33.04 ± 10.65b); STCp (13.76 ± 8.82c); ASCr (24.80 ± 7.99a); ASTCr (23.84 ± 7.16a); STCr (11.41 ± 11.71c). ANOVA and Post Hoc were applied. With the results of this study, we can conclude: The hypothesis H0 was rejected; H1 hypothesis was partially accepted because the heat treatment of the silane led to the highest average bond strength provided it is conducted in association with the hydrofluoric acid etching 10%, independent of the resin cement tested; H2 hypothesis was partially accepted because the cement with MDP averaged bond strength statistically superior to conventional cement when the conditioning was conducted with 10% hydrofluoric acid prior to the heat treatment of silane.
28

Síntese do 2,3-epitiopropil metacrilato e seu uso no desenvolvimento de um adesivo odontológico / 2,3-epithiopropyl methacrylate synthesis and application in a dental adhesive

Ogliari, Fabrício Aulo 10 July 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:18Z (GMT). No. of bitstreams: 1 Dissertacao_ Fabricio_Aulo_Ogliari.pdf: 587095 bytes, checksum: 8bb56a09354ea01200df793cf0e60ef5 (MD5) Previous issue date: 2009-07-10 / The aim of this study was to synthesize and to investigate the influence of the 2,3-epithiopropyl methacrylate (ETMA) in a dental adhesive. Synthesis of the ETMA was performed using glycidyl methacrylate as starting reagent, catalyzed by cerium ammonium nitrate in presence of NH4SCN. After purification, ETMA was characterized by 1H NMR and FTIR spectroscopy. ETMA monomer was used as an additive agent in a commercial available dental adhesive (Scotchbond Multipurpose, 3M ESPE) at three different concentrations (0.1, 1 and 10 wt %). Adhesive without ETMA was used as control group. Degree of conversion of the polymerized adhesives was accomplished by FTIR analysis. Blend copolymerization was investigated by 1H NMR spectroscopy analysis. To investigate immediate and long-term properties of the adhesives, microtensile bond strength to human dentin and SEM fractographic analysis were performed. ETMA was synthesized through the conversion of GMA with NH4SCN and high yield was obtained (90%). One-step s synthetic route and a simple manner of purification were described. ETMA presence didn t affect the degree of conversion of the adhesive resins. The monomer that composed the adhesive resins presented copolymerization among them, not presenting ETMA release in 0.1 and 1% groups. Experimental adhesives had statistically higher microtensile bond strength values than the no ETMA adhesive (p<0.05), independently of the water storage. All groups were stable over time / O objetivo deste estudo foi sintetizar e avaliar a influência do 2,3-epitiopropil metacrilato (ETMA) utilizado como monômero funcionalizado sobre a resistência de união imediata e longitudinal de um adesivo comercial. O ETMA foi sintetizado através da transformação do glicidil metacrilato na presença de tiocianato de amônio catalisado por nitrato de cérico de amônio. O produto obtido, após destilação, foi confirmado e caracterizado por ressonância magnética nuclear de prótons e por espectroscopia no infravermelho. ETMA foi utilizado como aditivo na quantidade de 0,1, 1 e 10% em massa a um adesivo comercial (Scotchbond Multiuso - SBMU, 3MESPE). Como controle SBMU sem ETMA foi testado. Foi avaliada a capacidade de copolimerização do ETMA com os outros monômeros do adesivo comercial assim como a sua influência no grau de conversão e na resistência de união à microtração em dentina. A resistência de união a microtração em dentina foi avaliada após 24h, 6 meses e 12 meses de armazenagem em água destilada. As amostras fraturadas do ensaio de microtração foram avaliadas por microscopia eletrônica de varredura e microscopia ótica para a análise do modo de fratura. Foi possível a síntese do ETMA através da conversão de GMA utilizando NH4SCN como reagente. Um rendimento global de 90% foi atingido utilizando-se um método simples de purificação. A adição de ETMA não influenciou os valores de grau de conversão e estes sistemas monoméricos demonstraram capacidade de copolimerização ente si, não apresentando traços de liberação de ETMA nos grupos de 0,1 e 1%. Os adesivos contendo ETMA apresentaram valores de resistência de união significativamente maiores que o grupo controle sem ETMA (p<0.05). Os valores de resistência de união do grupo controle e dos grupos experimentais permaneceram estáveis mesmo após 12 meses de armazenagem, sendo que os grupos experimentais apresentaram valores mais elevados de resistência de união em comparação ao controle independentemente do período de avaliação
29

Efetividade dos adesivos autocondicionantes na resistência da união em dentina tratada com clorexidina

Furtado, Carolina Oliveira de Andrade 29 April 2015 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2015-12-07T17:01:41Z No. of bitstreams: 1 carolinaoliveiradeandradefurtado.pdf: 2894297 bytes, checksum: f089f62fc6081d6501fc211279a846ba (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2015-12-07T21:41:56Z (GMT) No. of bitstreams: 1 carolinaoliveiradeandradefurtado.pdf: 2894297 bytes, checksum: f089f62fc6081d6501fc211279a846ba (MD5) / Made available in DSpace on 2015-12-07T21:41:56Z (GMT). No. of bitstreams: 1 carolinaoliveiradeandradefurtado.pdf: 2894297 bytes, checksum: f089f62fc6081d6501fc211279a846ba (MD5) Previous issue date: 2015-04-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A clorexidina (CHX) é um agente antimicrobiano com capacidade de retardar a ação das metaloproteinases em tecido dentinário condicionado com ácido fosfórico. Mas, especula-se que os produtos de sua reação podem interferir química e fisicamente sobre os valores imediatos de resistência da união (TBS) dos adesivos autocondicionantes universais. O objetivo foi analisar a influência do tratamento da destina com solução de CHX a 2% previamente a aplicação dos adesivos autocondicionantes e universais sobre TBS. Superfícies oclusais de 20 molares humanos hígidos foram removidas para expor superfície dentinária média. Estes foram divididos em 8 grupos de acordo com o tipo de tratamento submetido: SEself- aplicação do sistema adesivo Clearfil SE Bond de acordo com as instruções do fabricante; SEself + CHX: aplicação prévia da clorexidina por 20 s seguido pela lavagem; SBself: aplicação do adesivo Scotchbond Universal de acordo com as instruções do fabricante no modo autocondicionante; SBself + CHX: aplicação prévia de CHX por 20 s seguido da secagem; SEtotal: condicionamento com ácido fosfórico a 35% por 15 s seguido da lavagem, secagem, primer ácido por 10 s, adesivo e fotoativação deste por 10 s; SEtotal + CHX: sequência técnica semelhante ao anterior, porém com aplicação de CHX após o condicionamento ácido; SBtotal: aplicação do adesivo de acordo com as instruções do fabricante no modo condiciomento ácido total; SBtotal + CHX: após o condicionamento com ácido fósforico, a CHX foi aplicada por 20 s seguido pela secagem e aplicação do adesivo. Blocos em resina composta com 5 mm foram construídos sobre as superfícies hibridizadas, seccionados em palitos de 1 mm2 e armazenados em água deionizada a 37 ºC por 24 horas. Após, os corpos de prova foram submetidos ao teste de microtração com velocidade de 1 mm/min até a fratura. As médias obtidas foram submetidas a ANOVA dois fatores e ao teste Tukey (p = 0.05). No modo autocondicionante, os grupos SEself (39,77 ± 11,56MPa) e SBself (40,84 ± 12,49MPa) não diferiram entre si e foram superiores estatisticamente aos grupos Seself + CHX (22,86 ± 5,18MPa) e Sbself + CHX (27,02 ± 5,58MPa), os quais não apresentam diferença estatística entre si. No modo com condicionamento ácido total, o grupo SBU + CHX apresentou a maior média (37,81 ± 11,69MPa), seguido pelos grupos SBtotal (31,53 ± 9,22MPa) e SEtotal+CHX (28,09 ± 4,2MPa). Já o grupo SEtotal (25,95 ± 5,43MPa) apresentou a menor média e foi inferior estatisticamente aos demais. Conclui-se que a aplicação prévia da CHX sobre a dentina interferiu na efetividade dos valores de resistência da união dos sistemas autocondicionantes e universais à dentina. / Chlorhexidine (CHX) is an antimicrobial agent with ability to slow down the action of metalloproteinases in dentin tissue conditioning with phosphoric acid. But, it is speculated that the products of their reaction may interfere chemically and physically on the immediate values of bond strength (TBS) of self-etching universal adhesives. The objective was to analyze the influence of treatment designed with CHX solution 2% prior to application of self-etch and universal adhesives on TBS. Occlusal surfaces of 20 sound human molars were removed to expose middle dentin surface. These were divided into 8 groups according to the type of treatment submitted: SEself- application of Clearfil SE Bond adhesive system according to the manufacturer's instructions; SEself + CHX: prior use of chlorhexidine for 20 s followed by washing; SBself: applying Scotchbond Universal according to the manufacturer's instructions in self-etching mode; SBself + CHX: previous application of CHX for 20 s followed by drying; SEtotal: phosphoric acid etching to 35% for 15 sec followed by washing, drying, primer acid for 10 seconds, adhesive and curing this for 10 seconds; SEtotal + CHX: Technical sequence similar to the above, but with application of CHX after acid etching; SBtotal: applying the adhesive according to the manufacturer's instructions in order condiciomento Total acid; SBtotal + CHX: after phosphoric acid etching, CHX was applied for 20 s followed by drying and application of the adhesive. Composite resin blocks with 5mm were built on the hybridized surfaces, cut into sticks of 1 mm2 and stored in deionized water at 37 °C for 24 hours. Afterwards, the samples were submitted to microtensile test speed of 1 mm/min until failure. The averages were submitted to two factors ANOVA and Tukey test (p = 0.05). In the self-etching mode, the SEself groups (39.77 ± 11,56MPa) and SBself (40.84 ± 12.49) did not differ statistically and were superior to SEself + CHX groups (22.86 ± 5,18MPa) and SBself + CHX (27.02 ± 5,58MPa), which have no statistical difference between them. On the total etching mode, SBU + CHX group had the highest average (37.81 ± 11,69MPa), followed by SBtotal groups (31.53 ± 9,22MPa) and SEtotal + CHX (28.09 ± 4, 2 MPa). Already SEtotal group (25.95 ± 5.43MPa) had the lowest average and was statistically lower to the other groups. It was concluded that the prior application of CHX on dentine interfered in the effectiveness of bond strength values of self-etching dentin and universal systems.
30

Avaliação in vitro da resistência adesiva e degradação da interface de união entre cimentos resinosos e uma cerâmica aluminizada tratada internamente com laser / In Vitro analsis of bond strength and degradation method between bond interface of aluminous ceramic and resin cements

Silveira, Bruno Lopes da 04 July 2008 (has links)
O estudo teve o objetivo de avaliar a resistência adesiva e a degradação da interface entre uma cerâmica tratada com laser e cimentos resinosos. Sessenta e quatro blocos cerâmicos foram distribuídos em 16 grupos distribuídos de acordo com os fatores em estudo: tratamento da superfície interna da cerâmica: Oxido de Alumínio (Ox), Rocatec (R), Laser de Nd:YAG 141,54 J/cm2 (Nd) e Laser de Nd:YAG + Rocatec (NdR); cimentos resinosos: Panavia F (Kuraray) e Relyx Unicem (3M ESPE); e método de envelhecimento: água destilada (W) e hipoclorito de sódio 10% (H). Após os procedimentos de cimentação e corte dos blocos, metade dos palitos foi armazenada em solução de hipoclorito de sódio 10% para simular envelhecimento in vitro. A resistência de união foi avaliada através do ensaio de microtração (0,5 mm/min) e os padrões de fratura foram classificados em adesivo, coesivo ou misto. Blocos cerâmicos adionciais foram confeccionados e analisados em Microscopia Eletrônica de Varredura e em Microscópio de Força Atômica para verificação dos padrões gerados pelos tratamentos. Os grupos tratados com laser de Nd:YAG apresentaram os maiores valores de resistência de união. Para os grupos cimentados com Panavia F, os valores de resistência de união foram: OxW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; OxH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. Para os grupos com RelyX Unicem: OxW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; OxH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Pode-se concluir que o laser de Nd:YAG foi o tratamento mais efetivo, seguido da associação entre o laser de Nd:YAG+Rocatec, Rocatec e jateamento com Al2O3. Os cimentos testados apresentam comportamentos similares. O envelhecimento in vitro com hipoclorito de sódio diminuiu os valores de resistência de união. / The aim of this study was to evaluate the influence of different surface treatments on resistance to degradation between In-Ceram Alumina and two resin-based cements. Sixteen experimental groups were formed according to ceramic treatment: Sandblasting (S), Rocatec System (R), Nd:YAG Laser (Nd), Nd:YAG Laser plus Rocatec System (NR); luting cement: Panavia F (Kuraray) or Relyx Unicem (3M ESPE); and aging method: water (W) or sodium hypochlorite (H). Sixty four In-Ceram Alumina blocks (10x10x6mm) received four surface treatments: Al2O3 sandblasting; Al2O3 sandblasting + Rocatec Plus; Al2O3 sandblasting + Nd:YAG Lase; Al2O3 sandblasting + Nd:YAG Laser + Rocatec Plus. Each conditioned ceramic block was bonded to a composite block using a resin cement system. After 24h storage time, the blocks were sectioned to obtain sticks with cross-sectional area of 1.0mm2. The specimens were loaded to failure in a universal testing machine at a crosshead speed of 0.5mm/min. The fractured surface morphology of the debonded specimens was observed (40X) to evaluate the fracture pattern. Failure modes were classified as adhesive, cohesive in ceramic, cohesive in resin cement and mixed. The ceramic treatment and the aging method significantly affected the microtensile bond strength. Nd:YAG surface treatment resulted in the best bond strength values. To groups luted with Panavia F cement the microtensile bond strength values were: SW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; SH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. To groups luted with RelyX cement: SW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; SH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Nd:YAG laser was the most effective surface treatment, followed by Nd:YAG+Rocatec, Rocatec and Al2O3 sandblasting. Resin cements presented similar behaviors in spite of aging. NaOCl 12h-immersion decreased Bond strength values.

Page generated in 0.0757 seconds