• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 66
  • Tagged with
  • 66
  • 46
  • 40
  • 38
  • 37
  • 27
  • 26
  • 26
  • 24
  • 23
  • 19
  • 19
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Degradação de interfaces adesivas formadas após desmineralização e desproteinização da dentina / Long-term bond strengths of adhesive systems applied to etched and deproteinized dentin

Ninoshka Uceda Gómez 07 December 2007 (has links)
O objetivo deste estudo foi avaliar a resistência de união de 2 sistemas adesivos convencionais de dois passos (Single Bond-SB, 3MESPE e One Step-OS, Bisco) aplicados à dentina desmineralizada [SH] e desmineralizada e desproteinizada com NaOCl a 10% [CH], tanto no tempo imediato [IM] como após 12 meses de imersão em água [12M]. Realizou-se também a observação da morfologia das interfaces de união entre os sistemas adesivos e a superfície de dentina em Microscópio Eletrônico de Varredura (MEV) para cada grupo experimental. O esmalte oclusal de 20 molares permanentes hígidos foi removido para expor as superfícies planas de dentina, que foram condicionadas com H3PO4 a 37%, lavadas e secas (grupos SH). Para os grupos CH após o condicionamento ácido foi aplicado hipoclorito de sódio a 10% durante 60 s, seguido de lavagem por 15 s. Os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Coroas de resina composta (Z-250, 3MESPE) foram construídas de forma incremental (600 mW/cm² por 40 s). Após armazenagem em água por 24h a 37°C, os espécimes foram secionados para obter corpos-de-prova na forma de palitos (0,8mm²), que foram testados sob tração (0,5 mm/min) no tempo imediato [IM] ou após 12 meses de armazenamento em água. Dois dentes de cada grupo foram observados em MEV nos dois períodos de tempo. Os dados de resistência de união foram submetidos à uma análise de variância de três fatores e teste de Tukey para contraste das médias (p = 0,05). As interações duplas e triplas não foram estatisticamente significantes (p> 0,05), assim como o fator principal Tratamento de superfície (p = 0,05). Somente os fatores principais Adesivo e Tempo de armazenagem foram significantes (p = 0,04 e p = 0,03, respectivamente). O adesivo SB (43,3 ± 9,1 MPa) apresentou altos valores de resistência de união quando comparado com o OS (33,3 ± 11,6 MPa). A resistência de união do grupo IM (42,5 ± 8,7) foi estatisticamente superior à grupo 12M (33,3 ± 11,8). / The aim of this study was to evaluate the early and 12-month bond strengths of two adhesive systems (Single Bond-SB, 3MESPE and One Step-OS, Bisco) applied to demineralized dentin (WH) and demineralized/NaOCl-treated dentin (H). The adhesive interfaces were also micromorphologically evaluated by Scanning Electron Microscopy (SEM). Twenty flat dentin surfaces were exposed. They were etched, rinsed and slightly dried. For the H groups, a solution of 10% NaOCl was applied for 60s, rinsed (15 s) and slightly dried. The adhesives were applied according to the manufacturer\'s instructions and composite resin crowns were incrementally constructed. After 24 h (water-37°C), the sample was sectioned in order to obtain resin-dentin sticks (0.8 mm²). The specimens were tested in tension (0.5 mm/min) immediately (IM) or after 12 months of water storage (12M). Two teeth from each experimental group were restored as described previously and evaluated under SEM, under the two storage periods. The data (MPa) were subjected to three-way ANOVA and Tukey\'s test (? = 0.05). No significant effects for the triple and double interactions (p > 0.05) as well as for the main factor Surface treatment were observed (p > 0.05). Only the main factors Adhesive and Storage time were statistically significant (p = 0.004 and p = 0.003, respectively). The adhesive SB (42.3 ± 9.1) showed higher bond strengths than OS (33.6 ± 11.6). The mean bond strength for IM-group (42.5 ± 8.7) was statistically superior to 12M (33.3 ± 11.8). The use of 10% sodium hypochlorite, after acid etching, did not improve the immediate and the long term resin-dentin bond strengths for acetone and water/alcohol based adhesive systems.
42

Avaliação in vitro da resistência adesiva e degradação da interface de união entre cimentos resinosos e uma cerâmica aluminizada tratada internamente com laser / In Vitro analsis of bond strength and degradation method between bond interface of aluminous ceramic and resin cements

Bruno Lopes da Silveira 04 July 2008 (has links)
O estudo teve o objetivo de avaliar a resistência adesiva e a degradação da interface entre uma cerâmica tratada com laser e cimentos resinosos. Sessenta e quatro blocos cerâmicos foram distribuídos em 16 grupos distribuídos de acordo com os fatores em estudo: tratamento da superfície interna da cerâmica: Oxido de Alumínio (Ox), Rocatec (R), Laser de Nd:YAG 141,54 J/cm2 (Nd) e Laser de Nd:YAG + Rocatec (NdR); cimentos resinosos: Panavia F (Kuraray) e Relyx Unicem (3M ESPE); e método de envelhecimento: água destilada (W) e hipoclorito de sódio 10% (H). Após os procedimentos de cimentação e corte dos blocos, metade dos palitos foi armazenada em solução de hipoclorito de sódio 10% para simular envelhecimento in vitro. A resistência de união foi avaliada através do ensaio de microtração (0,5 mm/min) e os padrões de fratura foram classificados em adesivo, coesivo ou misto. Blocos cerâmicos adionciais foram confeccionados e analisados em Microscopia Eletrônica de Varredura e em Microscópio de Força Atômica para verificação dos padrões gerados pelos tratamentos. Os grupos tratados com laser de Nd:YAG apresentaram os maiores valores de resistência de união. Para os grupos cimentados com Panavia F, os valores de resistência de união foram: OxW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; OxH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. Para os grupos com RelyX Unicem: OxW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; OxH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Pode-se concluir que o laser de Nd:YAG foi o tratamento mais efetivo, seguido da associação entre o laser de Nd:YAG+Rocatec, Rocatec e jateamento com Al2O3. Os cimentos testados apresentam comportamentos similares. O envelhecimento in vitro com hipoclorito de sódio diminuiu os valores de resistência de união. / The aim of this study was to evaluate the influence of different surface treatments on resistance to degradation between In-Ceram Alumina and two resin-based cements. Sixteen experimental groups were formed according to ceramic treatment: Sandblasting (S), Rocatec System (R), Nd:YAG Laser (Nd), Nd:YAG Laser plus Rocatec System (NR); luting cement: Panavia F (Kuraray) or Relyx Unicem (3M ESPE); and aging method: water (W) or sodium hypochlorite (H). Sixty four In-Ceram Alumina blocks (10x10x6mm) received four surface treatments: Al2O3 sandblasting; Al2O3 sandblasting + Rocatec Plus; Al2O3 sandblasting + Nd:YAG Lase; Al2O3 sandblasting + Nd:YAG Laser + Rocatec Plus. Each conditioned ceramic block was bonded to a composite block using a resin cement system. After 24h storage time, the blocks were sectioned to obtain sticks with cross-sectional area of 1.0mm2. The specimens were loaded to failure in a universal testing machine at a crosshead speed of 0.5mm/min. The fractured surface morphology of the debonded specimens was observed (40X) to evaluate the fracture pattern. Failure modes were classified as adhesive, cohesive in ceramic, cohesive in resin cement and mixed. The ceramic treatment and the aging method significantly affected the microtensile bond strength. Nd:YAG surface treatment resulted in the best bond strength values. To groups luted with Panavia F cement the microtensile bond strength values were: SW: 27,71±6,3; RW: 35,67±5,13; NdW: 42,49±6,8; NdRW: 37,41±4,76; SH: 22,27±6,05; RH: 27,49±8,83; NdH: 32,24±6,94; NdRH: 31,75±7,77. To groups luted with RelyX cement: SW: 26,74±6,34; RW: 35,07±6,02; NdW: 41,05±7,71; NdRW: 33,85±6,03; SH: 22,77±7,37; RH: 27,84±6,26; NdH: 36,42±5,08; NdRH: 27,6±5,8. Nd:YAG laser was the most effective surface treatment, followed by Nd:YAG+Rocatec, Rocatec and Al2O3 sandblasting. Resin cements presented similar behaviors in spite of aging. NaOCl 12h-immersion decreased Bond strength values.
43

"Influência do volume de adesivo e das ciclagens térmica e mecânica na resistência de união resina-dentina" / Influence of the adhesive volume, thermal and mechanical load cycling on the resin-dentin bond strength

Edmea Lodovici 01 July 2005 (has links)
Interfaces adesivas flexíveis, com maior capacidade de dissipação de tensões poderiam prevenir falhas provenientes das tensões geradas durante a contração de polimerização, variações térmicas e esforços mastigatórios. Isso poderia ser obtido através do aumento da espessura da camada de adesivo. O objetivo deste trabalho foi comparar a resistência de união (RU) à dentina de dois sistemas adesivos (SA) aplicados com diferentes volumes de adesivo (uma ou duas camadas) e submetidos ou não às ciclagens térmica e mecânica (CTM). A superfície dentinária de 40 terceiros molares hígidos foi exposta com uma lixa de granulação 600. Dois sistemas adesivos foram testados: Scotchbond Multiuso (SBMU) e Clearfil SE Bond (CSEB). Seus respectivos adesivos foram aplicados através de uma micropipeta (8 ou 16µl) em uma área delimitada de 52 mm 2 e blocos de resina composta (Z250) foram construídos incrementalmente. Metade da amostra foi armazenada em água destilada por 24 h e submetida às ciclagens térmica (1.000; 5-55ºC) e mecânica (500.000 ciclos / 12 kgf). A outra metade foi apenas armazenada em água destilada por 72 h. Após isso, os dentes foram seccionados, longitudinalmente, em cortes perpendiculares entre si, a fim de se obterem corpos-de-prova em formato de paralelogramo com aproximadamente 0,8mm 2 de secção transversal. Os palitos foram submetidos ao teste de microtração a 1,0 mm/min e o modo de fratura analisado. A RU foi expressa como um índice que incluiu os valores de RU dos diferentes padrões de fratura, além dos palitos prematuramente fraturados (P). Os dados foram submetidos à análise de variância de 3 fatores. O teste de qui-quadrado foi utilizado (p<0,05) para verificar diferenças na freqüência de P. Dois fatores foram significantes: “SA” e “CTM”. SBMU e grupos não-ciclados apresentaram maior RU do que CSEB e grupos ciclados respectivamente. Uma maior freqüência de P foi observada para os grupos ciclados. Uma camada adicional de adesivo não influenciou na RU de interfaces feitas com SBMU ou CSEB, enquanto a CTM levou à redução da RU das interfaces. / Dentin bonding interfaces with increased capacity of stress dissipation are able to prevent failures due to polymerization contraction, thermal and mechanical stresses. This would be obtained by increasing adhesive layer thickness. The purpose of this study was to compare the resin-dentin microtensile bond strengths (BS) of two adhesive systems (AS) applied with different volumes of adhesive resin (one and two coats) submitted or not to thermal and mechanical loading (TML). A flat superficial dentin surface was exposed on 40 third molars with a 600-grit SiC paper. Two systems were tested: Scotchbond Multipurpose (SBMP) and Clearfil SE Bond (CSEB). After primer application, the adhesive layer was applied by a micropipette (8 or 16µl) to a delimited area (52mm 2 ) and resin blocks (Z250) were built incrementally. Half of the sample was stored in distilled water for 24h and then submitted to thermal (1,000; 5-55ºC) and mechanical cycles (500,000; 12kgf). The other half was stored in distilled water (72h). Teeth were then sectioned to obtain sticks (0.8 mm 2 ) to be tested under tensile mode (1.0mm/min). The fracture mode was analyzed at 400X. BS was expressed as an index that included the BS values of different fracture patterns and the prematurely debonded specimens (D). The data was analyzed by three-way ANOVA. The &#967; 2 test was used (p<0.05) to compare the frequency of D specimens. The main factors AS and TML were significant. SBMP and non-cycled groups showed higher BS to dentin. A higher frequency of D was observed for the cycled groups. The application of an adhesive layer in two coats for a three-step etch&rinse and a two-step self-etch systems, to act as an intermediate flexible layer, was not able to minimize the damage caused by thermal and mechanical load in a low C-factor cavity.
44

Avaliação da resisténcia de união e caracterização da camada híbrida formada por adesivos experimentais a base de metacrilato hidrófobo ou solvatado em 10% e 30% de etanol, aplicados sobre dentina saturada com etanol em um estudo de longevi / Evaluation of bond strength and characterization of hybrid layer produced by an experimental adhesive based on hydrophobic methacrylate or dissolved in 10% and 30% ethanol, applied to ethanol-saturated dentin in a longevity study

Andre Guaraci De Vito de Moraes 20 May 2009 (has links)
A longevidade da interface adesiva é afetada pelos efeitos da degradação hidrolítica, cuja ocorrência está associada ao alto conteúdo de água presente no tecido dentinário. A hibridização da dentina com monômeros hidrófobos em um substrato isento de água poderia fazer com que a resistência de união dessas interfaces se mantivesse estável por um período de tempo prolongado. O objetivo deste estudo foi avaliar a resistência de união, através do teste de microtração, da interface adesiva em dentina saturada com etanol, sobre a qual se fez o uso de um adesivo hidrófobo, além de caracterizar a morfologia desta interface. Vinte e oito dentes molares foram cortados para que um flat de dentina do terço médio fosse obtido. Foram estudados quatro grupos experimentais: Grupo controle (Scotchbond MultiUso, 3M ESPE), cuja dentina foi saturada com água, grupo experimental 1, cuja dentina saturada com etanol foi hibridizada com o adesivo hidrófobo puro do sistema Scotchbond e grupos experimentais 2 e 3, cuja dentina saturada com etanol recebeu primers hidrofóbicos dissolvidos em etanol 10% e 30% respectivamente. Após a hibridização da dentina, os dentes foram restaurados de forma incremental com resina composta (Filtek Z350, 3M ESPE). As resistências adesivas imediata (24 horas) e tardia (6 meses) foram avaliadas por -tração (0.5 mm/min) de palitos obtidos por cortes perpendiculares à interface adesiva, com área de seção transversal de 1 mm2. O meio de armazenagem dos palitos foi saliva artificial a 37°C. Amostras dos palitos foram preparadas para caracterização da interface adesiva e avaliação do modo de fratura em microscopia eletrônica de varredura. Os dados foram submetidos à análise de variância de dois fatores, Técnica Adesiva e Tempo de Armazenamento, sendo este último vinculado. Os resultados encontrados não mostraram diferença estatística para todos os grupos estudados após 6 meses de armazenamento quando comparados com os dados obtidos de forma imediata (24 horas). Também não foram encontradas diferenças entre os grupos quando avaliados em 24 horas e em 6 meses separadamente. A camada híbrida formada em dentina saturada por etanol apresentou características similares, em relação à morfologia e dimensão, àquela formada pela técnica convencional. A técnica de substituição de água por etanol produziu interfaces tão resistentes quanto à técnica úmida convencional, pelo menos nos primeiros seis meses. / The longevity of an adhesive interface is affected by the effects of hydrolytic degradation, which is associated with high water content in the dentin tissue. The hybridization of dentin with hydrophobic monomers in a water-free substrate could make the bond strength of these interfaces remain stable for an extended period of time. The aim of this study was to evaluate the bond strength of the adhesive interface in ethanol-saturated dentin using a microtensile test, on which a hydrophobic adhesive was used, and also to characterize the morphology of this interface. Twenty-eight molar teeth were cut to a flat middle third of the dentin was obtained. We studied four experimental groups: control group (Scotchbond MultiPurpose, 3M ESPE), whose dentin was saturated with water; experimental group 1, whose dentin saturated with ethanol was hybridized with the pure hydrophobic adhesive from Scotchbond adhesive system and experimental groups 2 and 3, whose dentin saturated with ethanol received hydrophobic primers dissolved in ethanol 10% and 30%, respectively. After dentin hybridization, teeth were restored with the incremental technique with composite resin (Filtek Z350, 3M ESPE). The immediate (24 hours) and late (6 months) adhesive resistance was determined by - tensile (0.5 mm / min) of \"sticks\" obtained by perpendicular cuts on the adhesive interface, with cross section area of 1 mm2. The sticks storage medium was artificial saliva at 37 °C. Interface samples were prepared to characterize the adhesive interface and to assess the failure mode by scanning electron microscopy. The data were submitted to two factors analysis of variance, adhesive technique and storage time, the latter being dependent. The results showed no statistical differences for all groups after 6 months of storage when compared to data obtained from the immediate group (24 hours). Also, no differences were found between groups evaluated at 24 hours and 6 months separately. The hybrid layer formed in ethanolsaturated dentin had similar characteristics considering the morphology and size formed by conventional technique. The technique of water replacement for ethanol produced interfaces as strong as the conventional wet technique, at least in the first six months.
45

Avaliação in vitro de diferentes protocolos utilizado na esplintagem dentária / Evaluation in vitro of different protocols used dental splinting

Amaral, Fabricio Reskalla 26 July 2010 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-09-15T19:46:11Z No. of bitstreams: 1 fabricioreskallaamaral.pdf: 2335161 bytes, checksum: 6c05fb00dba6c1d1e2679f0a3289f9ca (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2016-09-26T20:21:13Z (GMT) No. of bitstreams: 1 fabricioreskallaamaral.pdf: 2335161 bytes, checksum: 6c05fb00dba6c1d1e2679f0a3289f9ca (MD5) / Made available in DSpace on 2016-09-26T20:21:13Z (GMT). No. of bitstreams: 1 fabricioreskallaamaral.pdf: 2335161 bytes, checksum: 6c05fb00dba6c1d1e2679f0a3289f9ca (MD5) Previous issue date: 2010-07-26 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / OBJETIVO: Avaliar, por meio do ensaio de microtração, diferentes protocolos utilizados na esplintagem dentária, com fibra de vidro (FV), adesivo (Ad), resina flow (RF) e resina composta nanoparticulada (RCN). MATERIAIS E MÉTODOS: Foram confeccionados 84 blocos de resina nanoparticulada , com dimensões de 4,5 x 8 x 7mm e divididos em 7 grupos. Os blocos foram pareados (n=6) conforme o fator “protocolo de esplintagem”: Gr1- Ad ; Gr2- FV ; Gr3- FV + Ad; Gr4- RF+ FV + Ad; Gr5- FV + Ad + RF; Gr6- FV + RF + Ad; Gr7- RF + FV. Após, os conjuntos foram seccionados com um disco de diamante dupla face em um torno específico para corte dos corpos-de-prova em forma de palito (CP) com interface adesiva de 1mm2 sendo, posteriormente, submetidos ao teste de microtração (µTBS) em máquina de ensaio universal EMIC à velocidade de 1mm/s com célula de carga de 50KGF. Para determinar a fratura, as interfaces adesivas foram analisadas em microscópio eletrônico de varredura e os resultados submetidos à análise de variância ANOVA 1fator e teste Tukey para comparação das médias (α=5%). RESULTADOS: As médias (MPa) e desvio padrão (MPa) para µTBS foram: Gr1- 22,4 (13,4); Gr2- 3,9 (4,2);Gr3- 17,2 (7,7);Gr4- 12,6 (6,9);Gr5- 6,4 (5,5);Gr6- 7,8 (9,7);Gr7-12,1 (10,9). A análise estatística verificou diferença significante entre os grupos. CONCLUSÃO: Houve diferença estatisticamente significante (p< 0.05) na resistência de união entre os protocolos de esplintagem avaliados; o maior valor médio de resistência de união foi obtido pelo protocolo do grupo controle 1 (resina composta + adesivo); entre os grupos testes, o maior valor médio de resistência de união foi obtido pelo protocolo do grupo 3 (resina composta + fibra de vidro + adesivo). / OBJECTIVE: This study evaluated in vitro "different protocols used in the dental splinting with fiber glass (FG), adhesive (Ad), resin flow (RF) and nanoparticle composite (RCN). MATERIALS AND METHODS: We made 84 resin blocks nanoparticule with dimensions 4.5 x 8 x 7 mm and divided into seven groups. The blocks were paired (n = 6) as the factor "protocol splinting": Gr1-Ad; Gr2- FV; Gr3- FV + Ad; GR4- RF + FV + Ad; GR5- FV + Ad + PR; GR6- FV+ Ad + PR +; GR7- RF + FV. After the sets were cut with a diamond disc double-sided on a lathe for cutting specific bodies-of - proof-shaped stick (CP) at the bonding interface of 1mm2 was later submitted to microtensile test (μTBS) in EMIC universal test machine at a speed of 1mm / s with load cell 50kgf. To determine the fracture, the adhesive interfaces were examined in a scanning electron microscope and the results submitted to analysis of variance one-factor ANOVA and Tukey test for comparison of means (α = 5%). RESULTS: Mean (MPa) and standard deviation for μTBS were Gr1-22.4 (13.4); Gr2-3.9 (4.2); Gr3-17.2 (7.7); GR4-12, 6 (6.9); GR5-6.4 (5.5); GR6-7.8 (9.7); GR7-12, 1 (10.9). Statistical analysis found significant differences between groups. CONCLUSION: CONCLUSION: There was a statistically significant difference (p <0.05) in bond strength between splinting protocols evaluated, the larger value of bond strength was obtained by the filing of a control group (resin + adhesive) between the test groups, the highest average value of bond strength was obtained by the protocol of group 3 (composite resin + glass fiber + adhesive).
46

Efeito do condicionamento ácido adicional na resistência de união e Módulo de Weibull de sitemas adesivos aplicados em dentina sadia e afetada por cárie / Effect of additional acid etching on bond strength and Weibull modulus of adhesive systems applied on sound and affected dentin

Zanchi, Cesar Henrique 02 March 2007 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 1 Dissertacao_cesar_henrique_zanchi.pdf: 490684 bytes, checksum: 7c7bf328a3f694acdaf1aad686b90d1e (MD5) Previous issue date: 2007-03-02 / The aim of this study was to evaluate the effect of additional etching with phosphoric acid at 35% in the bond strength and Weibull modulus of two adhesive systems applied to sound and affected dentin. Ninety human molars with coronal carious lesion were sectioned to produce flat coronal superficies with effected dentin surrounded by sound dentin, and allocated in six experimental groups: SB-CT: Single Bond® applied to manufacture s instructions; SB+15: Single Bond® with additional etching for 15s; SB+30: Single Bond® with additional etching for 30s; CF-CT: Clearfil SE Bond® applied to manufacture s instructions; CF+15: Clearfil SE Bond® with additional etching for 15s; CF+30: Clearfil SE Bond® with additional etching for 30s. Afterwards, the crowns were built up with a composite resin and, after 24h, mesiondistal sectioned to produce 2 or 3 slices in each substratum. Thereafter (24h), the slices were trimmed in hourglass shape and submitted to micro-tensile test (n=30). The data were analyzed by three-way ANOVA, Tukey s test (p<0,05) and Weibull analysis. The bond strength to affected dentin was significantly lower than sound dentin for the adhesives systems employed, save SB+30. The additional etching increased the bond strength to affected dentin. To sound dentin, the additional etching increased the bond strength for Clearfil SE Bond®, but decreased for Single Bond®. The Weibull modulus to affected dentin was lower for both adhesives systems. On sound dentin, Single Bond® showed lower Weibull modulus than Clearfil SE Bond® and the additional etching decrease this value. Although the additional etching may increase the bond strength to affected dentin, the means were lower than sound dentin, the same for Weibull modulus. The additional etching may reduce the bond strength and Weibull modulus for Single Bond® to sound dentin and, in opposite, increase for Clearfil SE Bond® / O objetivo deste estudo foi avaliar o efeito do condicionamento adicional com ácido fosfórico à 35% na resistência de união e módulo de Weibull de dois sistemas adesivos aplicados em dentina sadia e afetada por cárie. Noventa molares humanos com lesão cariosa oclusal foram desgastados produzindo superfícies oclusais planas, com DAC circundada por DS, e divididos em seis grupos experimentais: SBCT: Single Bond® aplicado conforme o fabricante; SB+15: Single Bond® com condicionamento ácido adicional de 15s; SB+30: Single Bond® com condicionamento ácido adicional 30s; CF-CT: Clearfil SE Bond® aplicado conforme o fabricante; CF+15: Clearfil SE Bond® com condicionamento ácido adicional de 15s; CF+30: Clearfil SE Bond® com condicionamento ácido adicional de 30s. Após, as coroas dos dentes foram restauradas em formato de bloco e, posteriormente (24h), seccionadas no sentido mésio-distal originando 2-3 fatias em cada substrato. Após 24h as fatias foram recortadas em formato de ampulheta e submetidas ao ensaio de microtração (n=30). Os valores de resistência de união foram analisados com ANOVA (3- fatores), teste de Tukey (p<0,05) e análise de Weibull. Em geral, a resistência de união foi significantemente menor em dentina afetada por cárie que em dentina sadia para ambos os sistemas adesivos, exceto para SB+30. O condicionamento ácido adicional resultou no aumento da resistência de união em dentina afetada por cárie. Em dentina sadia o condicionamento ácido adicional aumentou a resistência de união para o sistema Clearfil SE Bond®, mas reduziu para o sistema Single Bond®. O módulo de Weibull foi menor em dentina afetada por cárie para os dois sistemas adesivos. Em dentina sadia, Single Bond® apresentou menor módulo de Weibull que Clearfil SE Bond® e o condicionamento ácido adicional resultou na redução desse valor. Embora o condicionamento ácido adicional possa aumentar a resistência de união em dentina afetada por cárie, as médias foram menores que em dentina sadia, bem como o módulo de Weibull. O condicionamento ácido adicional 11 pode reduzir a resistência de união e o módulo de Weibull para Single Bond® em dentina sadia e, contrariamente, aumentar para o sistema Clearfil SE Bond®
47

Tetrahidrofurano como solvente de adesivos odontológicos / Tetrahydrofuran as solvent in dental adhesive systems

Fontes, Silvia Terra 27 February 2009 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1 Dissertacao_ Terra_Silvia_ Fontes.pdf: 826039 bytes, checksum: 1168fd40390593dc923413d4c46c356d (MD5) Previous issue date: 2009-02-27 / The aim of this study is to evaluate the performance of tetrahydrofuran (THF) as solvent in the primer composition of an experimental adhesive system on the resin-dentin microtensile bond strength after 24h and 6 months of water storage. Sixty bovine incisors will be randomly separated into ten groups, according to the solvent type: 1) THF, 2) acetone, 3) ethanol, 4) water, 5) THF/water, 6)acetone/water, 7) ethanol/water, 8) All Bond 2 (acetone/ethanol/water), 9) Opti Bond FL (ethanol/water) e 10) Scotch Bond (water). Vestibular enamel will be removed to, expose the superficial dentin and further polished with grit silicon-carbide under irrigation. After acid etching with 35% phosphoric acid (15s), the surfaces will be rinsed with water (30s) and the excess of superficial water will be removed with absorbent paper. Each experimental primer will be applied with agitation (30s) followed by a gently air stream (10s) at a distance of 10cm to help solvent evaporation. One coat of an experimental adhesive resin will be applied and lightactivated (20s). The marketed available adhesive systems will be used according manufacturer instructions. Resin composite restorations will be constructed incrementally. Each layer of composite will be light-activated individually at 1400mW/cm2. After water storage for 24h at 37oC, the restored teeth will be sectioned to obtain sticks with a cross-sectional area of approximately 0.5mm2. Half of specimens will be tested after 24 hours and the other half will be maintained in the same storage conditions to be evaluated after 6 months. Microtensile bond strength (MPa) will be evaluated with an universal testing machine (1.0mm/min/100N). The half corresponding to dentin will be evaluated in a light microscope (500X) and classified as: CD) cohesive in dentin, CC) cohesive in resin composite, A) adhesive, M) mixed or PD) premature debonded. Statistical significance will be set at α=0.05 / O objetivo deste estudo será avaliar o desempenho do tetrahidrofurano (THF) como solvente na composição do primer de um adesivo odontológico experimental através da resistência de união à microtração em dentina após 24h e 6 meses de armazenamento em água. Sessenta incisivos bovinos serão distribuídos aleatoriamente em dez grupos, conforme o tipo de solvente: 1) THF, 2) acetona, 3) etanol, 4) água, 5) THF/água, 6) acetona/água, 7) etanol/água, 8) All Bond 2 (acetona/etanol/água), 9) Opti Bond FL (etanol/água) e 10) Scotch Bond (água). O desgaste na face vestibular dos dentes será realizado até exposição da dentina superficial com lixas de carbeto de silício sob refrigeração. Depois que a superfície dentinária for condicionada com gel de ácido fosfórico a 35% (15s) e lavada com água (30s), o excesso de água superficial será removido com papel absorvente. Nos grupos experimentais, o primer será aplicado sob agitação constante (30s) seguido de jato de ar por (10s) a distância de 10cm, a fim de auxiliar a evaporação do solvente. Uma camada de resina adesiva experimental será aplicada e fotoativada (20s). Os sistemas adesivos de marcas comerciais serão aplicados conforme instruções dos fabricantes. As restaurações serão realizadas com compósito restaurador pela técnica incremental. Os incrementos serão fotoativados individualmente a 1400mW/cm2. Após o período de 24 horas de armazenamento em água a 37ºC, as amostras serão seccionadas obtendo-se uma área de secção transversal de aproximadamente 0,5mm2. Metade dos corpos de prova será testada imediatamente e a outra metade será mantida sob as mesmas condições de armazenamento para avaliação após 6 meses.A resistência de união à microtração (MPa) será testada através de uma máquina universal de ensaios mecânicos (1,0mm/min/100N). As porções correspondentes à dentina serão analisadas por microscopia de luz (500X) e classificadas de acordo com o padrão de fratura em: CD) falhas coesivas em dentina, CC) falhas coesivas em compósito restaurador, A) falhas adesivas, M) falhas mistas ou FP) falhas prematuras. Significância estatística será considerada quando α=0.05
48

EFEITOS DO PRÉ-TRATAMENTO DENTINÁRIO E TEMPERATURA DO ADESIVO NA RESISTÊNCIA ADESIVA DE UM SISTEMA ADESIVO UNIVERSAL / EFFECTS OF DENTIN PRETREATMENT AND ADHESIVE TEMPERATURE ON BOND STRENGTH OF A UNIVERSAL ADHESIVE SYSTEM

Sutil, Bruna Gabrielle da Silva 28 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aimed to evaluate the effects of dentin pretreatment and temperature on the bond strength of a universal adhesive system to dentin. Ninety-six extracted non-carious human third molars were randomly divided into 12 groups (n=8) according to Scotchbond Universal Adhesive (SbU) applied in self-etch (SE) and total-etch (TE) mode, adhesive temperature (20ºC or 37ºC) and sodium bicarbonate or aluminum oxide air abrasion. After composite build up, bonded sticks with cross-sectional area of 1 mm² were obtained to evaluate the microtensile bond strength (μTBS). The specimens were tested at a crosshead speed of 0.5 mm/min on a universal testing machine until failure. Fractured specimens were analyzed under stereomicroscope to determine the failure patterns in adhesive, cohesive (dentin or resin) and mixed fractures. The microtensile bond strength data was analyzed using to two-way ANOVA and Tukey s test (p<0.01). Interaction between treatment and temperature was statistically significant to SbU applied in SE technique. Both dentin treatments showed higher bond strength to TE mode, regardless of adhesive temperature. When compared to control group, sodium bicarbonate increased bond strength of SbU in SE mode. Adhesive temperature did not significantly affect the μTBS of tested groups. Predominantly, adhesive failure was observed for all groups. Thus, the dentin pretreatment may be an alternative to improve the adhesive properties of the Scotchbond Universal adhesive system. / O presente estudo avaliou os efeitos do jateamento de partículas abrasivas e da temperatura sobre a resistência adesiva de um sistema adesivo universal à dentina. Utilizou-se 96 terceiros molares humanos hígidos e extraídos, divididos aleatoriamente em 12 grupos (n=8) de acordo com o adesivo Scotchbond Universal (SBU) aplicado no modo autocondicionante (SE) ou condicionamento ácido total (TE), temperatura do adesivo (20ºC ou 37ºC) e jateamento da dentina com partículas de óxido de alumínio ou bicarbonato de sódio. Após a realização das restaurações, foram obtidos espécimes em forma de palito com área seccional de 1 mm² para avaliar a resistência adesiva através do teste de microtração. O teste foi realizado em uma máquina de ensaio universal, a uma velocidade de 0,5 mm/min até a fratura ocorrer. As fraturas foram analisadas sob estereomicroscopia para classificar as falhas em adesiva, coesiva (resina ou dentina) e mista. Os dados foram submetidos ao teste ANOVA a dois fatores e ao teste de Tukey. A interação entre tratamento e temperatura foi estatisticamente significante (p<0,01) para SBU SE. Ambos os tratamentos da dentina resultaram em valores maiores de resistência adesiva para SBU no modo TE, independente da temperatura do adesivo. Já para SBU aplicado na técnica autocondicionante, apenas o jateamento com bicarbonato de sódio foi significativamente diferente quando comparado ao grupo que não recebeu tratamento. O adesivo aquecido não teve influência significativa sobre a resistência adesiva à microtração, para todos os grupos testados. As fraturas adesivas foram predominantes para todos os grupos. Dessa forma, o pré-tratamento dentinário pode ser uma alternativa para melhorar as propriedades adesivas do sistema adesivo Scotchbond Universal.
49

Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laser

Ramos, Thaysa Monteiro 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
50

Efeito do retardamento da polimerização da base de cimento de ionômero de vidro modificado por resina na resistência adesiva em restaurações de resina composta / Effect of delaying photoativation of resin modified glass-ionomer cement used as a liner on the bond strength of composite resin restorations

Casas Apayco, Leslie Caroll 22 April 2009 (has links)
Durante o processo inicial da reação de presa, o cimento de ionômero de vidro modificado por resina (CIVMR) apresenta baixo módulo de elasticidade, característica importante quando utilizado como base de restaurações com resina composta, por diminuir o estresse de contração de polimerização nas paredes cavitárias. O presente estudo teve como objetivo analisar a influência da técnica de polimerização de uma base CIVMR (VitrebondTM) por resina na interface dente/restauração de resina composta, através de teste de microtração e análise em microscopia confocal. Foram utilizados 30 dentes molares humanos hígidos extraídos, nos quais foram confeccionadas cavidades padronizadas em sua face oclusal (5mm de comprimento x 3mm de largura x 4,5mm profundidade). O sistema adesivo utilizado AdperTM Single Bond 2 foi marcado previamente com Rodamina B (0,16mg/ml), para possibilitar a análise em microscópio confocal. Os dentes foram divididos em 3 grupos: Grupo 1 (controle): base de CIVMR VitrebondTM + fotoativação + sistema adesivo + resina composta FiltekTM Z250; Grupo 2: base de CIVMR VitrebondTM + sistema adesivo + fotoativação por 30 segundos simultânea dos dois materiais + resina composta FiltekTM Z250; Grupo 3: base de CIVMR por resina VitrebondTM + tempo de espera de 60 segundos + fotoativação + sistema adesivo + resina composta FiltekTM Z250. Após a restauração, os dentes permaneceram em água deionizada em estufa a 37 ºC por 24 horas. Em seguida, foram seccionados com disco de diamante em fatias de aproximadamente 0,8mm no sentido vestíbulo-lingual. Uma fatia de cada dente foi separada aleatoriamente para análise da presença de fendas na interface dentina/resina composta em microscopia confocal. As demais fatias foram seccionadas para a confecção de palitos, para os testes de microtração. Os resultados de resistência de união foram submetidos à análise de variância a um critério ANOVA a 5% e teste de qui-quadrado para as variáveis de presença de fendas marginais e tipo de fratura resultante (p<0,05). Não houve diferença estatisticamente significante entre os três grupos (p=0,644) com relação à resistência adesiva e tipo de fratura, predominando a fratura do tipo adesiva para todos os grupos. Quanto à presença de fendas marginais internas, foi evidenciada sua presença nos grupos 2 e 3, sem diferença estatisticamente significante entre os três grupos testados (p=0,082). Conclui-se, portanto, que a técnica de polimerização da base de cimento de ionômero de vidro modificado por resina não influencia na resistência adesiva da interface dente/restauração de resina composta. / During the initial process of setting reaction, the resin-modified glass-ionomer cement (RMGIC) shows low modulus of elasticity, which is an important characteristic when RMGIC is used as a liner in resin composites restorations, because it decreases the polymerization shrinkage stress in cavity walls. The aim of this study was to analyze the influence of polymerization techniques of resin-modified glass-ionomer cement used as a liner on the adhesive interface dentin/resin by microtensile test and confocal microscopic analysis. Standardized occlusal cavity preparations (5mm length x 3mm wide x 4.5mm depth) were prepared in 30 human extracted molars. For the analysis at the confocal microscope, the adhesive system AdperTM Single Bond 2 was previously marked with rodhamine B (0.16mg/ml). The tooth were divided into three groups: Group 1 (control): RMGIC liner VitrebondTM + photoactivation for 30 seconds + adhesive system + resin composite Filtek TM Z250; Group 2: RMGICs liner VitrebondTM + adhesive system + simultaneous photoactivation of both materials + resin composite FiltekTM Z250; Group 3: RMGICs liner VitrebondTM+ 60 seconds delay time + photoativation for 30 seconds + adhesive system + resin composite FiltekTMZ250. Specimens were stored at 37ºC in deionized water for 24 hours. After this period, tooth was sectionated in 0.8mm slices (buco-lingual). One slice of each tooth was randomly selected for confocal microscopy for analysis of the interface resin/dentin. The other slices were sectionated in sticks (mesio-distal) for microtensile test. One-way ANOVA (p<0.05) showed no significant statistical difference among groups 1, 2 and 3 (p=0.644). Quisquare test showed no significant statistical difference of type of fracture (adhesive fracture was predominant) and presence of gap at the interface dentin/resin among groups. (p=0.082). It can be concluded, that polymerization technique of resin-modified glassionomer cement (RMGIC) did not influence bond strength and dentin/resin composite interface.

Page generated in 0.1052 seconds