• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 58
  • 10
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 80
  • 15
  • 14
  • 14
  • 14
  • 13
  • 12
  • 11
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Miniaturisation d'actionneurs sur une optique adaptative à base de ferrofluide

Vassallo, Julien 17 April 2018 (has links)
L'utilisation d'un miroir liquide déformable à base de ferrofluide est l'une des nouvelles applications en optique adaptative. Ce miroir liquide déformable possède l'avantage, en comparaison du miroir solide déformable, de générer un faible coût de production des actionneurs ainsi qu'une grande amplitude de déformation de la surface du miroir. Ce mémoire est dédié à l'étude de la miniaturisation des actionneurs composant le miroir déformable. Ainsi, au sein d'un système d'optique adaptatif actuel muni d'un miroir déformable liquide à base de ferrofluide, des bobines de 5 mm de diamètre sont utilisées en tant qu'actionneurs afin de créer un champ magnétique qui déforme la surface du ferrofluide. La miniaturisation des actionneurs doit permettre l'amélioration de la finesse des déformations, la diminution de l'espace occupé par le système optique ainsi que la baisse des coûts de production. Pour se faire, une diminution de la largeur à demi-hauteur des déformations gaussiennes à la surface du liquide est requise afin de créer différents systèmes d'actionneurs de diamètres inférieurs à 5 mm. En premier lieu, la technologie des bobines électriques est privilégiée. Ainsi, un système de bobines de 2,5 mm de diamètre est étudié où l'importance du coeur magnétique de la bobine apparaît. Afin de diminuer la largeur à demi-hauteur de la déformation, un système d'immersion est mis en place avec une bobine de 1,5 mm de diamètre. La limite physique de la technologie des bobines électriques est alors atteinte. Afin d'outrepasser cette limite, un système de boucle de courant entouré d'un champ magnétique permanent permet d'obtenir des actionneurs de 1,2 mm de diamètre. En conclusion, l'avenir des actionneurs du miroir déformable liquide devrait avoir comme point d'appui la technologie des MEMS avec des actionneurs de 400 ptm.
22

Caractérisation d'un miroir déformable à ferrofluide à réponse linéaire

Naderiyanha, Azadeh 18 April 2018 (has links)
Le concept de miroir déformable à base de liquide magnétique (ferrofluide) a énormément contribué à la technologie des miroirs déformables. Les miroirs déformables à ferrofluide (MDFs) permettent des déformations qui peuvent varier de quelques nanometres jusqu'à quelques millimètres, ce qui est largement supérieur à ce que les miroirs déformables commerciaux peuvent produire. Toutefois, un inconvénient majeur de ces MDFs est leur réponse non linéaire. Une nouvelle technique qui permet de surmonter ce problème est de superposer un champ magnétique constant et uniforme au champ magnétique produit par les action-neurs. Nous avons fabriqué un MDF à 91 actionneurs qui utilise cette nouvelle technique de linéarisation. Les performances obtenues sont comparables à celles des miroirs déformables disponibles commercialement. Les premiers 36 polynômes de Zernikes ont été produits en utilisant ce miroir et, basés sur nos mesures, nous prévoyons des amplitude maximales sur le front d'onde qui peuvent atteindre plus de 70 [mu]m. La combinaison linéaire de polynômes de Zernike, la reproductibilité au fil du temps, ainsi que l'application de ce MDF à compenser les aberrations de l'oeil humain est présentée.
23

Étude d'un résonateur laser adapté supergaussien à miroir à gradient de phase

Lachance, Richard L. 18 October 2023 (has links)
Le présent projet concerne la conception, la fabrication et l'analyse d'un nouveau type de résonateur laser appelé résonateur adapté, caractérisé par la présence d'un miroir asphérique profilé de manière à opérer en un mode spécifié par le concepteur. Deux de ces résonateurs, intégrés dans un laser pulsé de type CO₂ — TEA à géométrie semiconfocale, sont conçus pour générer des faisceaux supergaussiens d'ordre 4 et 6 dans le mode fondamental. Les miroirs à gradient de phase (MGP) ont été fabriqués grâce à la technique du tournage au diamant dans un substrat de cuivre. Cette géométrie particulière permet d'une part d'accroître le volume du mode fondamental, entraînant une plus grande efficacité d'extraction d'énergie monomode, et d'autre part d'augmenter la discrimination par rapport aux modes supérieurs, améliorant ainsi les performances du laser. Un modèle numérique reposant sur une superposition incohérente des modes dans un milieu de gain saturé, permet de simuler adéquatement le comportement expérimental observé.
24

Algorithme novateur de contrôle d'un miroir déformable à base de ferrofluide

Bouffard Landry, Daniel 19 April 2018 (has links)
Un nouvel algorithme de contrôle de miroir déformable à base de ferrofluide a été proposé afin de répondre à un besoin spécifique des entreprises de fabrication de lentille de précision. Il s'est avéré efficace pour améliorer la précision du contrôle en boucle ouverte par rapport à la méthode usuelle. Il a été estimé que le miroir utilisé pouvait produire une surface avec une fiabilité à X/5, à la condition de porter une attention particulière aux instruments utilisés. Les analyses de reproductivité ont confirmé la faible sensibilité du système aux paramètres potentiellement problématiques et ont permis de déterminer une erreur maximale de 2
25

Axicon conique à angle variable à base de ferrofluide

Drapeau, Julie 16 April 2018 (has links)
Les axicons ont mené à de nombreux articles dans la littérature depuis l'invention de ce terme. Toutefois, ce n'est que récemment que les axicons coniques sont devenus populaires et fréquemment utilisés en laboratoire. Ces éléments, le plus souvent de profil conique, sont généralement fabriqués en verre, ce qui rend impossible de varier l'angle du cône, paramètre le plus critique dans la formation du faisceau de Bessel. Gagner ce degré de liberté permettrait de varier la taille et la longueur du faisceau de Bessel dynamiquement. Cela ouvrirait la porte à de nouvelles applications et permettrait de faire plusieurs expériences en n'achetant qu'un seul axicon. Le miroir déformable ferrofluidique sur lequel notre groupe de recherche travaille depuis plusieurs années pourrait générer un tel axicon en réflexion. Contrairement aux autres miroirs déformables sur le marché, ce miroir atteint de grandes amplitudes de déformations et ne génère pas d'hystérésis, ce qui explique pourquoi les miroirs déformables conventionnels n'ont pas déjà conduit à un axicon déformable satisfaisant. Ce mémoire détaille un peu de théorie utile, mais surtout les simulations et les expériences qui ont mené au résultat final. Nous avons produit un axicon conique en réflexion dont l'angle varie de 0.004 à 0.157 degré. Il est donc possible de faire un axicon dont l'angle varie linéairement et de façon continue en utilisant un miroir déformable ferrofluidique. Des travaux futurs pourront agrandir la plage d'angles atteinte par le miroir et peut-être produire d'autres formes d'axicon variable comme des axicons elliptiques ou logarithmiques.
26

Analysens påverkan på musikalisk interpretation : en analys av Alborada del gracioso av Maurice Ravel

Granath, Joline January 2017 (has links)
I detta examensarbete analyseras Alborada del gracioso ur Miroirs av den franske kompositören och pianisten Maurice Ravel, främst ur ett motiviskt och strukturellt perspektiv. Analysen innefattar även reflektioner kring några av författarens interpretationsmässiga val och lösningar på vissa tekniska problem. Syftet med studien är att undersöka om och hur en analys av verket påverkar interpretationen av detsamma. Studiens resultat påvisar att analysen kan leda till en förändring av interpretationen, på grund av att den ger en djupare förståelse av verket och ger möjlighet till mer välmotiverade val i interpretationen.
27

Effet des lésions neurodégénératives sur le mécanisme de résonance motrice à l’observation d’action / The effect of neurodegenerative lesions on the mechanism of motor resonance induced by action observation

Farina, Elisabetta Ismilde Mariagiovan 23 October 2018 (has links)
Le concept de "cognition incarnée" considère que le schéma classique Perception-Cognition-Action proposant un flux séquentiel de traitement de l’information n'est pas approprié pour comprendre l'effet comportemental des troubles neurodégénératifs et trouver des solutions thérapeutiques innovantes. La découverte des neurones miroirs (NM) a donné un substrat biologique à cette théorie: on pense maintenant que les NM relient les connaissances sur les actions et les perceptions non seulement pour intégrer la perception dans la planification et l'exécution, mais aussi pour soutenir un large éventail de fonctions cognitives, par ex. empathie et langage. En même temps, il est maintenant clair que dans chaque maladie neurodégénérative les symptômes cognitifs et moteurs sont représentés le long d'un continuum. Les maladies neurodégénératives liées au vieillissement, comme la maladie d'Alzheimer (MA), la forme la plus courante de démence, sont devenues un enjeu social très important. Comme il n'y a pas de remède pour la MA, les études se concentrent sur la prévention. Une catégorie qui représente maintenant une cible privilégiée est le trouble cognitif léger (TCL), considéré comme une étape intermédiaire entre le vieillissement normal et la MA. Même si MA et TCL ont été caractérisées comme des maladies «cognitives» jusqu'à présent, un lien entre la fonction motrice et le risque de développer la MA a été reconnu.Le but principal de cette recherche est d'étudier l'intégrité du réseau NM dans la MA, le TCL et le vieillissement normal. La caractérisation de son fonctionnement dans les maladies neurodégénératives serait utile pour une meilleure compréhension de leurs mécanismes fonctionnels et manifestations cliniques. Cela permettrait également d’exploiter le NM dans la réhabilitation des symptômes.La thèse comprend deux parties : la première inclue une vaste recherche bibliographique destinée à décrire le cadre scientifique qui justifie une telle recherche.Nous avons d'abord passé en revue les preuves sur l'existence d'un système NM chez les singes et les humains, et ses multiples rôles possibles et après brièvement décrit le tableau clinique des principaux troubles neurodégénératifs, en montrant comment les symptômes cognitifs et moteurs s’entrecroisent. Ensuite, nous avons détaillé les résultats de la recherche documentaire sur les maladies neurodégénératives, NM et cognition incarnée, en les commentant à la lumière de cette théorie.La deuxième partie de la thèse décrit la procédure expérimentale qui a été réalisée dans le but de la recherche.Trois groupes appariés de 16 sujets chacun (CA-contrôles âgées, TCL amnésique avec atrophie hippocampique et MA) ont été évalués avec une batterie neuropsychologique centrée sur les fonctions liées au système NM, et une tâche IRMf spécifiquement créée pour tester les NM: celle- ci était constituée d'une tache d’observation, où aux sujets ont été montrés des vidéos d'une main droite saisissant différents objets, et d'une tache motrice où les sujets ont observé des images d'objets orientés pour être saisis avec la main droite, et ont fait le geste correspondant.Chez les CA, l'analyse de conjonction (comparant l'activation de l'IRMf pendant l'observation et l'exécution) a indiqué l'activation d'un réseau bilatéral fronto-pariétal dans les zones NM « classiques» et du gyrus temporal supérieur (STG), entrée visuelle corticale aux NM. Le groupe TCL a montré une activation similaire, cependant, les zones pariétales ont été moins activées et le STG n'a pas été activé, tandis que l'inverse était vrai pour la zone de Broca droite. Nous n'avons observé aucune activation du réseau fronto-pariétal chez le groupe MA. Dans tous les tests neuropsychologiques (y compris les tests de fonctions attribuées à NM), les sujets MA ont été plus mauvais que les CA, alors que les sujets TCL montraient seulement des troubles de mémoire épisodique et fluidité sémantique (...). / The concept of “embodied cognition” considers that the classical Perception-Cognition-Action architecture proposing a sequential flow of processing with clean cuts between all modules is not appropriate to understand the behavioral effect of neurodegenerative disorders and to find innovative therapeutic solutions. In the last decades, the discovery of the mirror neurons (MN) has given a biological substrate to this theoretical perspective: the MN are now thought linking together knowledge about actions and perceptions not only to integrate perception in action planning and execution but also as a neural mechanism supporting a wide range of cognitive functions, e.g. empathy and language. At the same time, it is now clear that in each neurodegenerative disease both cognitive and motor symptoms are represented along a continuum. In the current demographic context, neurodegenerative diseases linked to aging have become a very important social issue. Alzheimer Disease (AD), the most common form of dementia, is a neurodegenerative disease strictly linked to aging. As actually there is no cure, several studies are focusing on prevention. A category which now represents a preferential target of intervention is Mild Cognitive Impairment (MCI), considered as an intermediate stage between normal aging and AD. Even if AD and MCI have been characterized as “cognitive” diseases until now, a link between motor function and the risk of developing AD has been recognized.The main purpose of this research is to investigate the integrity of the MN network in AD, MCI and normal aging. Characterizing the functioning of the MN network in neurodegenerative diseases would be useful to better understand functional mechanisms and their clinical manifestations. It would also allow to capitalize on these kinds of neurons in the rehabilitation of motor and cognitive symptoms.The thesis consists of two parts: the first part includes an extensive bibliographic research intended to describe the scientific frame which justifies such a research.We first reviewed the evidence about the existence of a MN system in monkeys and humans, and its multiple possible roles in humans.We then briefly reviewed the clinical picture of the main neurodegenerative disorders, showing how cognitive and motor symptoms intersect in all of them.Next, we detailed the results of literature searching on neurodegenerative diseases, MN, and embodied cognition, commenting them at the light of this hypothesis.The second part of the thesis describe the experimental procedure which has been performed to evaluate the integrity of the MN network in normal elderly and people with AD and MCI, and its results.Three matched groups of 16 subjects each (normal elderly-NE, amnesic MCI with hippocampal atrophy and AD) were evaluated with a neuropsychological battery centered on functions thought to be linked to the MN system, and a fMRI task specifically created to test MN: that comprised of an observation run, where subjects were shown videos of a right hand grasping different objects, and of a motor run, where subjects observed visual pictures of objects oriented to be grasped with the right hand, and made the corresponding gesture.In NE subjects, the conjunction analysis (comparing fMRI activation during observation and execution), indicated the activation of a bilateral fronto-parietal network in “classical” MN areas, and of the superior temporal gyrus (STG), an area thought to provide the cortical visual input to the MN. The MCI group showed the activation of areas belonging to the same network, however, parietal areas were activated to a lesser extent and the STG was not activated, while the opposite was true for the right Broca’s area. We did not observe any activation of the fronto-parietal network in AD participants (...).
28

Les fondements génétiques de la représentation des actions d'autrui

Taschereau-Dumouchel, Vincent 23 April 2018 (has links)
Au cours des dernières années, plusieurs questions furent soulevées par la découverte d’un système neuronal permettant la mise en correspondance des représentations visuelles et motrices d’une même action lors de l’observation d’actions. Plus particulièrement, de quelle façon ce système acquiert-il cette intrigante propriété et quelle fonction remplie-t-il? Les perspectives théoriques actuelles proposent que le développement de ce système, appelé le système des neurones miroirs (SNM), soit régulé à la fois par des facteurs génétiques et par l’apprentissage associatif afin de faciliter des processus de cognition sociale de plus haut niveau, tel que l’empathie. Notons que jusqu’à présent, aucun facteur génétique n’a pu être associé au développement et au fonctionnement de ce système. La présente thèse propose d’évaluer l’influence d’une variation génétique sur l’activité et le fonctionnement du SNM, le polymorphisme Val66Met du Facteur neurotrophique dérivé du cerveau (Brain-derived Neurotrophic Factor; BDNF). Ce facteur génétique fut notamment associé à l’apprentissage moteur et à l’adaptation visuomotrice dans certaine région du système. Les résultats de la présente thèse indiquent que le polymorphisme Val66Met du BDNF influence la réponse du SNM lors de l’observation d’actions. Cette influence serait possiblement opérée par l’action du polymorphisme sur l’apprentissage associatif, lui-même influencé par ce facteur génétique (Article 1). De plus, les résultats obtenus indiquent une association entre ce polymorphisme et l’empathie autorapportée qui ne peut être attribuable à d’autres facteurs génétiques préalablement associés à cette mesure (Article 2). Ces observations ont inspiré la proposition d’une nouvelle approche psychophysique permettant d’offrir une alternative aux méthodes actuelles visant l’étude des interactions gène-gène et gène-environnement en neuroimagerie génétique (Article 3). Les résultats présentés constituent la première démonstration empirique de l’influence d’un facteur génétique sur l’apprentissage et le fonctionnement du SNM. Bien que ce facteur génétique puisse moduler le SNM et l’empathie autorapportée, les résultats obtenus ne permettent toutefois pas de statuer sur le lien direct entre ces deux phénotypes fréquemment associés dans la littérature. Cette contribution scientifique permet l’avancée de la compréhension du système des neurones miroirs, un système ayant été grandement étudié pour son rôle dans des psychopathologies associées à des symptômes sociaux cognitifs telles que la schizophrénie. / Many questions were raised by the discovery of the mirror neuron system (MNS), a neural system involves in the transformation of visual representations of action into fined-grained changes in the motor system during action observation. Notably, how does this system acquire this property and what is its function? Contemporary perspectives propose that the MNS might be regulated both by genetics and associative learning in order to facilitate higher-order social cognitive processes, such as empathy. Although, so far, no genetic variant was directly or indirectly associated to the development or to the function of this system. This dissertation aims at determining the influence of a specific genetic variant, the polymorphism Val66Met of the Brain-derived Neurotrophic factor (BDNF), on the activity and the function of the system. This genetic variant has previously been associated to motor learning and to visuomotor adaptation in regions of the mirror system. The results indicate that the BDNF val66Met polymorphism influences the response of the MNS during action observation. More precisely, this effect might be confered throught the action of the polymorphism on visuomotor associative learning (Article 1). Moreover, the results indicate an association between this polymorphism and self-reported empathy that cannot be explained by two other genetic variants commonly associated with this measure (Article 2). These observations led to the propostion of a new psychophysical conceptualisation of the effect of genetic variants in genetic neuroimaging that could facilitate the study of the complex gene-by-gene and gene-by-environement interactions in the field (Article 3). These results represent the first empirical evidence suggesting an influence of a specific genetic variant on the activity and function of the MNS. Our results do not indicate a direct link between the MNS and self-reported empathy, but indicate independent influences of the BDNF Val66Met on both phenotypes. This scientific contribution furthers our understanding of the mirror neuron system, a system widely studied for its role in psychopathologies linked to social cognitive symptoms such as schizophrenia.
29

Contrôleur évolutif et optimisé pour les miroirs déformables ferrofluidiques dans le cadre de l'optique adaptative

Libbrecht, Christophe 23 April 2018 (has links)
L’optique adaptative est une technologie s’intégrant de plus en plus à de nombreuses applications, de la capture d’images astronomiques à la transmission de données en télécommunication, tout en passant, par exemple, par l’amélioration des diagnostics en ophtalmologie. Son atout principal réside dans un miroir déformable lui permettant d’améliorer un signal dégradé par des perturbations. Il existe une grande variété de miroirs déformables. Certains ont une surface continue ; d’autres sont segmentés. Toute une batterie de techniques sont employées pour déformer et contrôler leur surface : des systèmes hydrauliques, piézoélectriques, électrostatiques et magnétiques ont été développés au fil des dernières années. Les derniers nés durant cette évolution technologique sont les miroirs ferrofluidiques. Les miroirs ferrofluidiques ont de nombreux points forts. Outre leur faible coût de conception, ils ont la capacité de fournir de grandes amplitudes (de l’ordre du millimètre) de déformation sous l’influence d’une combinaison de champs magnétiques. Ces miroirs sont développés et étudiés au sein des laboratoires du COPL à l’université Laval. Ils sont l’objet principal sur lequel s’appliquera le présent travail. Actuellement, le nombre sans cesse croissant des actionneurs oblige le développement de méthodes optimales de contrôle. Selon le domaine d’application, une image ou un signal capté nécessitera une dizaine, voire plusieurs centaines de corrections par seconde. Il est donc important que les calculs se fassent rapidement. D’autre part, ce nombre croissant d’actionneurs amène la question de la meilleure stratégie à suivre pour le contrôle optimal de la surface du miroir. Doit-on se restreindre à l’utilisation d’un unique contrôleur ou, au contraire, à en multiplier leur nombre au point que chaque actionneur possédera son propre contrôleur ? Quelle que soit la stratégie déployée, la phase de calibration est une étape clé. Pour un contrôleur en optique adaptative, elle est assez simple même si elle s’avère parfois longue lors de la recherche des paramètres optimaux. Quelle est la meilleure méthode pour calibrer le contrôleur ? Une calibration automatisée est-elle envisageable ? Peut-on espérer que le contrôleur évolue et s’adapte si les conditions ambiantes changent et cela sans intervention humaine ? Plus en avant, les questions suivantes concernent la mise en application de la stratégie : est-elle aisément applicable ? Sous quelles conditions ? Y aura-t-il des limitations ? Si oui, sont-elles significatives ? Sont-elles insurmontables ? Le présent travail tente de répondre à ces questions dans le cadre du contrôle de miroirs ferrofluidiques, quel que soit le contexte de l’utilisation d’un tel miroir. L’objectif final est de développer un contrôleur évolutif et optimal capable de gérer un système équipé aussi bien de quelques dizaines d’actionneurs que de plusieurs centaines, et s’ajustant de lui-même aux conditions environnementales sans cesse en évolution. / Adaptive optics is an evolving technology and integrated part of many applications. Its contributions extend from the astronomical imaging to the data transmission in telecommunications domain including the improvement of ophthalmologic diagnostics. Its main asset consists of its deformable mirrors and, thus, its ability to correct a signal degraded by random perturbations. There are many kinds of deformable mirrors. These with a continuous surface and also with several segments. A great variety of methods exists to control the surface geometry: hydraulics, piezoelectric, electrostatic and magnetic systems have been developed in the last years. The most recent creation in adaptive optics is the ferrofluidic mirror. The ferrofluidic mirrors have many advantages. First, their manufacturing cost is very low. Moreover, a simple combination of magnetic fields is required to modify the shape of their surface and can give strong amplitudes of deformation (about millimeter). These mirrors are developed and studied in the COPL laboratory of Université Laval where they are the main target of the actual work. Nowadays the constant increasing number of actuators decrees the development of optimized methods to control deformable mirrors. A captured image or signal can require from some tens to several hundreds of Hertz to be corrected. The calculations must be at their fastest. On other hand, the increasing number of actuators raises a question about what strategy to deploy for getting the best control on the surface of deformable mirrors. Do we use a single controller for all the actuators? Or on the contrary do we need to equip each actuator with a dedicated controller? For any chosen strategy, the most important step is the calibration phase. In adaptive optics, this procedure is quite simple even though it sometimes takes a long time for finding the optimized parameters. What is the best method to calibrate a controller? Is an automatic calibration possible? Can we develop an evolving controller able to adapt to environmental variations without human action. There is some interrogation about the best way to apply th strategy. Can it be more efficient? Are there any limitations? If so, can we solve them? The subject of this document is to answer the previous questions regarding ferrofluidic mirrors. The final purpose of this work is to develop an evolving and optimized controller able to manage systems with several tens as well as several hundreds of actuators and, also, adapt itself to variations of surrounding conditions.
30

Comportement spatial de miroirs déformables à base de liquide magnétique

Brousseau, Denis. 12 April 2018 (has links)
Ce travail consiste à démontrer l'intérêt d'utiliser des liquides magnétiques (ferrofluides) pour la fabrication de miroirs déformables dont la surface est modifiable par un champ magnétique. Une partie de ce travail consiste en une amélioration technologique d'un concept de miroir déformable à base de ferrofluide développé par Laird en 2005. Après avoir introduit le concept de miroir déformable ferrofluidique et présenté les constituants de base d'un système d'optique adaptative, nous explorons les nouvelles applications de l'optique adaptative qui ont vu le jour au cours des dix dernières années. Ces nouvelles applications ont crée un besoin pour le développement de nouveaux miroirs déformables à faible coût et possédant des caractéristiques différentes des systèmes classiques utilisés initialement pour l'astronomie. Nous incluons ensuite un chapitre traitant des technologies existantes de miroirs déformables. Un chapitre entier suit afin d'établir les bases théoriques et les techniques utilisées pour simuler le comportement spatial de ces miroirs. Trois types de miroirs déformables ferrofluidiques sont présentés dans ce chapitre et reposent tous sur l'utilisation de boucles de courant et/ou de réseaux de fils comme sources de champ magnétique. Ensuite, le comportement spatial de ces miroirs déformables est étudié expérimentalement à l'aide de trois prototypes conçus dans notre laboratoire. Nous présentons aussi dans ce chapitre des exemples d'applications de ces miroirs pour la correction d'aberrations statiques, introduites dans un système optique par le désalignement de composantes optiques ou la présence d'éléments aberrants. En dernier lieu, nous discutons des résultats obtenus avec ces prototypes, nous introduisons quelques applications potentielles pour ces miroirs déformables et présentons les avantages et inconvénients d'une telle technologie. / This work shows the usefulness of using magnetic liquids (ferrofluids) for the fabrication of deformable mirrors whose surface can be shaped by magnetic fields. Part of this work consists of a technological improvement of a concept of ferrofluidic deformable mirror developed by Laird in 2005. After an introduction on the concept of the ferrofluidic deformable mirror, we present the basic components of an adaptive optics System. Next, we explore new applications of adaptive optics that have emerged during the last decade. These new applications have created an interest in the design of affordable deformable mirrors with characteristics different from those commonly used in Astronomy. We then present a chapter discussing of existing technologies of deformable mirrors. The following chapter is devoted to the theoretical basis and the techniques used to simulate the spatial behavior of these ferrofluidic deformable mirrors. Three types of mirrors are presented in this chapter, each of which use current loops and/or wire network as sources of magnetic field. The spatial behavior of these deformable mirrors is studied in experiments using three prototypes designed in our laboratory. In this chapter, we also present applications of these mirrors for the correction of static aberrations, introduced to an optical System by the misalignment of the components or the presence of aberrant elements. Lastly, we discuss results obtained for these prototypes and introduce potential applications of these deformable mirrors, presenting the advantages and disadvantages of such a technology.

Page generated in 0.097 seconds