• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 5
  • 1
  • Tagged with
  • 21
  • 21
  • 21
  • 12
  • 10
  • 10
  • 9
  • 7
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise ecocardiográfica anatômica e funcional intraoperatória da valva mitral em pacientes com prolapso valvar submetidos à valvoplastia cirúrgica: estudo transesofágico bidimensional e tridimensional / Intraoperative anatomic and functional analyses of mitral valve in patients with valve prolapsed submitted to surgical valvuloplasty: a two-dimensional and three-dimensional transesophageal study

Pardi, Mirian Magalhães 01 December 2014 (has links)
Introdução: Embora o papel da ecocardiografia transesofágica (ETE) esteja bem estabelecido na avaliação morfológica e funcional da valva mitral e na seleção dos pacientes com prolapso da valva mitral (PVM) para a cirurgia reparadora, o impacto da ETE tridimensional (3D) no resultado cirúrgico ainda não está bem demonstrado. Os objetivos deste trabalho foram avaliar o valor diagnóstico adicional da ETE 3D em comparação com a técnica bidimensional (2D) e a associação de parâmetros anatômicos tridimensionais com o resultado cirúrgico em pacientes com PVM submetidos à valvoplastia. Métodos: Para a análise comparativa da sensibilidade, especificidade e acurácia diagnóstica entre ETE 2D e 3D, foram incluídos 62 pacientes operados por PVM com insuficiência importante, sendo a inspeção cirúrgica considerada padrão-ouro. Para a análise 3D, foram estudados 54 pacientes submetidos à plástica valvar que foram divididos em 2 grupos de acordo com o grau da insuficiência mitral pós-operatória (grupo 1, insuficiência mitral ausente ou grau I; grupo 2, insuficiência mitral grau II ou III). Foram medidos pela quantificação 3D os seguintes parâmetros anatômicos: diâmetros anteroposterior e intercomissural, altura, circunferência e área do anel mitral; comprimento, área e linha de coaptação das cúspides; volume e altura do prolapso; distância dos músculos papilares à borda da cúspide; e ângulos mitroaórtico e não planar. Para a identificação de variáveis associadas aos grupos de resultados cirúrgicos, foi realizada análise univariada (teste t de Student para as variáveis contínuas e teste qui-quadrado ou o teste de Fisher para as variáveis categóricas), análise multivariada com método de regressão logística e curva ROC para a obtenção do ponto de corte. Resultados: A ETE 2D apresentou maior sensibilidade no diagnóstico de prolapso nos segmentos A2, P1 e P3 que a ETE 3D (p = 0,019, 0,023, 0,012, respectivamente) enquanto que a ETE 3D apresentou maior especificidade no segmento P1 (p = 0,006). Não houve diferença na acurácia diagnóstica ente os dois métodos. A presença de prolapso das duas cúspides (p = 0,041) e a distância do músculo papilar posteromedial à borda da cúspide (p = 0,038) foram maiores no grupo 2. Análise multivariada identificou prolapso das duas cúspides e distância do músculo papilar posteromedial à borda da cúspide maior que 30 mm como fatores associados à insuficiência mitral pós-operatória grau II ou III (p = 0,039 e 0,015, respectivamente), e com risco de 5,3 e 6,3 vezes maior de insuficiência significativa pós-operatória, respectivamente. Conclusões: A ETE 2D e 3D apresentaram acurácia equivalente no diagnóstico de PVM, com maior sensibilidade da ETE 2D no diagnóstico de prolapso nos segmentos A2, P1 e P3, e maior especificidade da ETE 3D no segmento P1. A distância do músculo papilar posteromedial à borda da cúspide obtida pela análise quantitativa 3D e a presença de prolapso das duas cúspides mostraram associação com o grau da insuficiência mitral pós-operatória grau II e III / Background: Although the transesophageal echocardiography (TEE) is well established in the morphological and functional assessment of the mitral valve and in the choice of patients with mitral valve prolapse (MVP) eligible to valvuloplasty, the impact of tridimensional (3D) TEE on surgical results has not been well demonstrated yet. The present study aimed to evaluate the additional diagnostic value of 3D TEE in comparison with bidimensional (2D) technique, as well as the correlation between 3D anatomical parameters and the surgical results in patients with MVP submitted to valvuloplasty. Methods: In order to compare the sensitivity, specificity, and accuracy between 2D and 3D TEE, 62 patients with MVP and severe mitral regurgitation were enrolled; surgical appraisal was considered as the gold-standard. Regarding 3D analysis, 54 patients submitted to valvuloplasty were divided in two groups, according to their postoperative mitral regurgitation grades (group 1, absent or grade I mitral regurgitation; and group 2, grade II or III mitral regurgitation). The following parameters were assessed quantitatively by 3D TEE: anteroposterior diameter, commissural width, height, circumference and area of the mitral ring; anterior and posterior leaflets length, leaflets surface area, coaptation length, volume and height billow; distance from the tip of the anterolateral and posteromedial papillary muscle to leaflet border; non-planar and aortic-mitral angles. Univariate analysis (Student t test for continuous variables and Chi-square or Fischer test to the categorical ones), multivariate and ROC curve analyses were performed to identify the relationship between anatomical parameters and surgical results (p < 5%). Results: 2D TEE showed higher sensitivity to diagnose MVP in A2, P1, and P3 segments, when compared with 3D TEE (p= 0.019, 0.023, and 0.012, respectively), while 3D TEE showed greater specificity to identify P1 segment (p= 0.006). No difference was observed in the accuracy between both methods. The presence of bileaflet prolapse (p= 0.041) and the distance from posteromedial papillary muscle to leaflet border (p= 0.038) were higher in group 2. Multivariate analysis showed that bileaflet prolapse and distance of more than 30 mm from posteromedial papillary muscle to leaflet border were related to grade II or III postoperative mitral regurgitation (p= 0.039 and 0.015, respectively), representing 5.3 and 6.3 more risk of significant mitral regurgitation, respectively. Conclusions: Both 2D TEE and 3D TEE presented similar accuracy in the diagnosis of MVP; 2D TEE showed higher sensitivity to diagnose the prolapse in A2, P1 and P3 segments, while the 3D TEE presented greater specificity to identify the affected P1 segment. The distance from the tip of the posteromedial papillary muscle to the leaflet border quantitatively estimated by 3D TEE and the evidence of bileaflet prolapse showed to be associated to the degree of mitral regurgitation after valvuloplasty
12

Evolução e complicações de ferimentos cardíacos: estudo de coorte prospectivo na cidade de Manaus / Evolution and complications of cardiac wounds: cohort prospective study in the city of Manaus

Costa, Cleinaldo de Almeida 08 May 2008 (has links)
Objetivos: Avaliar a evolução e as complicações dos doentes que sobreviveram a ferimentos cardíacos, atendidos no Pronto-Socorro Municipal 28 de Agosto e Hospital Pronto-Socorro Dr. João Lúcio Pereira Machado, em Manaus, no período de janeiro de 1998 a junho de 2006. Métodos: Foi realizada uma busca de prontuários dos doentes atendidos nos dois prontossocorros, nos quais durante a toracotomia exploradora evidenciou-se o ferimento cardíaco. Os sobreviventes que retornaram ao ambulatório foram avaliados prospectivamente por meio de eletrocardiograma e ecocardiograma, para averiguar a morfologia e a funcionalidade do coração. Foi preenchido um protocolo com registro dos dados dos doentes, tais como: idade, sexo, mecanismo de trauma, complicações intra e pós-operatórias, dentre outras variáveis. Resultados: A população de referência totalizou 100 doentes, dos quais 95% eram homens, 69% entre 20 e 30 anos; 81% das lesões foram por arma branca, sendo que em 78% delas, a entrada se encontrava no precórdio; 41% das lesões acometeram o ventrículo direito (VD) e 38% acometeram o ventrículo esquerdo (VE); em 48% dos casos foi realizada toracotomia ântero-lateral esquerda. A sobrevivência foi de 72%. A população de estudo foi composta por 25 doentes que retornaram ao ambulatório e foram avaliados prospectivamente por meio de eletrocardiograma e ecocardiograma. Das 33 alterações no ecocardiograma (ECO), sete doentes (28%) tinham insuficiência mitral, enquanto nove (36%) não tinham alterações. Das 45 alterações no eletrocardiograma (ECG), oito doentes (32%) tinham taquicardia sinusal, enquanto seis (24%) não tinham alterações. Não houve efeito do tempo no resultado do ECO (p=0,5323) ou do ECG (p=0,6596). Das alterações detectadas no ECO, três (21,4%) foram devidas a lesões grau IV (em VD) e 11 (78,7%) devidas a lesões grau V (em VE) (p=0,048). Das 12 alterações detectadas no ECG, três (25%) relacionaram-se a lesões grau IV e nove (75%) relacionaram-se a lesões grau V (p=0,226). Conclusões: Aproximadamente um terço dos sobreviventes a lesões cardíacas não apresentaram alterações ao eletrocardiograma e ecocardiograma. Ventrículo esquerdo e grau de lesão V da OIS-AAST estiveram relacionados a um maior número de alterações ao eletrocardiograma e ecocardiograma. Taquicardia sinusal e insuficiência mitral foram alterações encontradas em um de cada três doentes que sobreviveram a um ferimento cardíaco. / Objectives: To evaluate the evolution and the complications of the patients that survived cardiac wounds, attended at the Pronto-Socorro Municipal 28 de Agosto and Hospital Pronto-Socorro Dr. João Lúcio Pereira Machado, in Manaus, during the period of January 1998 until June 2006. Methods: A medical records evaluation was made among the patients attended at the two emergency hospitals in which a cardiac wound was found during a exploring thoracotomy. The survivors that returned to the ambulatory were evaluated prospectively through electrocardiogram and echocardiogram, so it was possible to analyze the morphology and the function of the heart. A protocol was filled out with a registry of patients data, such as: age, sex, trauma mechanism, intra-operative and post-operative complications, and other variables. Results: The total reference population in this study was 100 patients, in which 95% were male, the majority (69%) had ages until 30; 81% of the lesions were caused by stab wounds; 78% of the orifice of entry were located at the precordium; 41% of the lesions wounded the right ventricle and 38% wounded the left ventricle; In 48% of the cases a left antero-lateral thoracotomy was executed. The survival rate was 72%. The studied population was of 25 patients that returned to the ambulatory and were prospectively evaluated with electrocardiogram and echocardiogram. Among the 33 echocardiogram alterations (ECO), seven patients (28%) had mitral insufficiency, while nine (36%) didn\'t have any alterations. Among the 45 electrocardiogram alterations (ECG), eight patients (32%) had sinusal tachicardia, while six (24%) had no alterations. Time made no difference in the results of the ECO (p=0,5323) or of the ECG (p=0,6596). Of the 14 detected ECO complications, three (21,4%) were due to IV degree lesions in the right ventricle and eleven (78,7%) were due to V degree lesions (in the left ventricle) (p=0,048). From the 12 left ventricle lesions that complicated (ECG), 9 were V degree. From the 12 alterations detected at the ECG, three (25%) were due to IV degree lesions and nine (75%) were due to V degree lesions (p=0,226). Conclusions: Approximately one third of the cardiac wound survivors did not have alterations in the electrocardiogram and echocardiogram. Left ventricle and V degree lesions from the OIS-AAST were related to a larger number of alterations in the electrocardiogram and echocardiogram. Sinusal Tachicardia and mitral insuficiency were alterations found in one third of the patients that survived a cardiac wound.
13

Análise ecocardiográfica anatômica e funcional intraoperatória da valva mitral em pacientes com prolapso valvar submetidos à valvoplastia cirúrgica: estudo transesofágico bidimensional e tridimensional / Intraoperative anatomic and functional analyses of mitral valve in patients with valve prolapsed submitted to surgical valvuloplasty: a two-dimensional and three-dimensional transesophageal study

Mirian Magalhães Pardi 01 December 2014 (has links)
Introdução: Embora o papel da ecocardiografia transesofágica (ETE) esteja bem estabelecido na avaliação morfológica e funcional da valva mitral e na seleção dos pacientes com prolapso da valva mitral (PVM) para a cirurgia reparadora, o impacto da ETE tridimensional (3D) no resultado cirúrgico ainda não está bem demonstrado. Os objetivos deste trabalho foram avaliar o valor diagnóstico adicional da ETE 3D em comparação com a técnica bidimensional (2D) e a associação de parâmetros anatômicos tridimensionais com o resultado cirúrgico em pacientes com PVM submetidos à valvoplastia. Métodos: Para a análise comparativa da sensibilidade, especificidade e acurácia diagnóstica entre ETE 2D e 3D, foram incluídos 62 pacientes operados por PVM com insuficiência importante, sendo a inspeção cirúrgica considerada padrão-ouro. Para a análise 3D, foram estudados 54 pacientes submetidos à plástica valvar que foram divididos em 2 grupos de acordo com o grau da insuficiência mitral pós-operatória (grupo 1, insuficiência mitral ausente ou grau I; grupo 2, insuficiência mitral grau II ou III). Foram medidos pela quantificação 3D os seguintes parâmetros anatômicos: diâmetros anteroposterior e intercomissural, altura, circunferência e área do anel mitral; comprimento, área e linha de coaptação das cúspides; volume e altura do prolapso; distância dos músculos papilares à borda da cúspide; e ângulos mitroaórtico e não planar. Para a identificação de variáveis associadas aos grupos de resultados cirúrgicos, foi realizada análise univariada (teste t de Student para as variáveis contínuas e teste qui-quadrado ou o teste de Fisher para as variáveis categóricas), análise multivariada com método de regressão logística e curva ROC para a obtenção do ponto de corte. Resultados: A ETE 2D apresentou maior sensibilidade no diagnóstico de prolapso nos segmentos A2, P1 e P3 que a ETE 3D (p = 0,019, 0,023, 0,012, respectivamente) enquanto que a ETE 3D apresentou maior especificidade no segmento P1 (p = 0,006). Não houve diferença na acurácia diagnóstica ente os dois métodos. A presença de prolapso das duas cúspides (p = 0,041) e a distância do músculo papilar posteromedial à borda da cúspide (p = 0,038) foram maiores no grupo 2. Análise multivariada identificou prolapso das duas cúspides e distância do músculo papilar posteromedial à borda da cúspide maior que 30 mm como fatores associados à insuficiência mitral pós-operatória grau II ou III (p = 0,039 e 0,015, respectivamente), e com risco de 5,3 e 6,3 vezes maior de insuficiência significativa pós-operatória, respectivamente. Conclusões: A ETE 2D e 3D apresentaram acurácia equivalente no diagnóstico de PVM, com maior sensibilidade da ETE 2D no diagnóstico de prolapso nos segmentos A2, P1 e P3, e maior especificidade da ETE 3D no segmento P1. A distância do músculo papilar posteromedial à borda da cúspide obtida pela análise quantitativa 3D e a presença de prolapso das duas cúspides mostraram associação com o grau da insuficiência mitral pós-operatória grau II e III / Background: Although the transesophageal echocardiography (TEE) is well established in the morphological and functional assessment of the mitral valve and in the choice of patients with mitral valve prolapse (MVP) eligible to valvuloplasty, the impact of tridimensional (3D) TEE on surgical results has not been well demonstrated yet. The present study aimed to evaluate the additional diagnostic value of 3D TEE in comparison with bidimensional (2D) technique, as well as the correlation between 3D anatomical parameters and the surgical results in patients with MVP submitted to valvuloplasty. Methods: In order to compare the sensitivity, specificity, and accuracy between 2D and 3D TEE, 62 patients with MVP and severe mitral regurgitation were enrolled; surgical appraisal was considered as the gold-standard. Regarding 3D analysis, 54 patients submitted to valvuloplasty were divided in two groups, according to their postoperative mitral regurgitation grades (group 1, absent or grade I mitral regurgitation; and group 2, grade II or III mitral regurgitation). The following parameters were assessed quantitatively by 3D TEE: anteroposterior diameter, commissural width, height, circumference and area of the mitral ring; anterior and posterior leaflets length, leaflets surface area, coaptation length, volume and height billow; distance from the tip of the anterolateral and posteromedial papillary muscle to leaflet border; non-planar and aortic-mitral angles. Univariate analysis (Student t test for continuous variables and Chi-square or Fischer test to the categorical ones), multivariate and ROC curve analyses were performed to identify the relationship between anatomical parameters and surgical results (p < 5%). Results: 2D TEE showed higher sensitivity to diagnose MVP in A2, P1, and P3 segments, when compared with 3D TEE (p= 0.019, 0.023, and 0.012, respectively), while 3D TEE showed greater specificity to identify P1 segment (p= 0.006). No difference was observed in the accuracy between both methods. The presence of bileaflet prolapse (p= 0.041) and the distance from posteromedial papillary muscle to leaflet border (p= 0.038) were higher in group 2. Multivariate analysis showed that bileaflet prolapse and distance of more than 30 mm from posteromedial papillary muscle to leaflet border were related to grade II or III postoperative mitral regurgitation (p= 0.039 and 0.015, respectively), representing 5.3 and 6.3 more risk of significant mitral regurgitation, respectively. Conclusions: Both 2D TEE and 3D TEE presented similar accuracy in the diagnosis of MVP; 2D TEE showed higher sensitivity to diagnose the prolapse in A2, P1 and P3 segments, while the 3D TEE presented greater specificity to identify the affected P1 segment. The distance from the tip of the posteromedial papillary muscle to the leaflet border quantitatively estimated by 3D TEE and the evidence of bileaflet prolapse showed to be associated to the degree of mitral regurgitation after valvuloplasty
14

Evolução e complicações de ferimentos cardíacos: estudo de coorte prospectivo na cidade de Manaus / Evolution and complications of cardiac wounds: cohort prospective study in the city of Manaus

Cleinaldo de Almeida Costa 08 May 2008 (has links)
Objetivos: Avaliar a evolução e as complicações dos doentes que sobreviveram a ferimentos cardíacos, atendidos no Pronto-Socorro Municipal 28 de Agosto e Hospital Pronto-Socorro Dr. João Lúcio Pereira Machado, em Manaus, no período de janeiro de 1998 a junho de 2006. Métodos: Foi realizada uma busca de prontuários dos doentes atendidos nos dois prontossocorros, nos quais durante a toracotomia exploradora evidenciou-se o ferimento cardíaco. Os sobreviventes que retornaram ao ambulatório foram avaliados prospectivamente por meio de eletrocardiograma e ecocardiograma, para averiguar a morfologia e a funcionalidade do coração. Foi preenchido um protocolo com registro dos dados dos doentes, tais como: idade, sexo, mecanismo de trauma, complicações intra e pós-operatórias, dentre outras variáveis. Resultados: A população de referência totalizou 100 doentes, dos quais 95% eram homens, 69% entre 20 e 30 anos; 81% das lesões foram por arma branca, sendo que em 78% delas, a entrada se encontrava no precórdio; 41% das lesões acometeram o ventrículo direito (VD) e 38% acometeram o ventrículo esquerdo (VE); em 48% dos casos foi realizada toracotomia ântero-lateral esquerda. A sobrevivência foi de 72%. A população de estudo foi composta por 25 doentes que retornaram ao ambulatório e foram avaliados prospectivamente por meio de eletrocardiograma e ecocardiograma. Das 33 alterações no ecocardiograma (ECO), sete doentes (28%) tinham insuficiência mitral, enquanto nove (36%) não tinham alterações. Das 45 alterações no eletrocardiograma (ECG), oito doentes (32%) tinham taquicardia sinusal, enquanto seis (24%) não tinham alterações. Não houve efeito do tempo no resultado do ECO (p=0,5323) ou do ECG (p=0,6596). Das alterações detectadas no ECO, três (21,4%) foram devidas a lesões grau IV (em VD) e 11 (78,7%) devidas a lesões grau V (em VE) (p=0,048). Das 12 alterações detectadas no ECG, três (25%) relacionaram-se a lesões grau IV e nove (75%) relacionaram-se a lesões grau V (p=0,226). Conclusões: Aproximadamente um terço dos sobreviventes a lesões cardíacas não apresentaram alterações ao eletrocardiograma e ecocardiograma. Ventrículo esquerdo e grau de lesão V da OIS-AAST estiveram relacionados a um maior número de alterações ao eletrocardiograma e ecocardiograma. Taquicardia sinusal e insuficiência mitral foram alterações encontradas em um de cada três doentes que sobreviveram a um ferimento cardíaco. / Objectives: To evaluate the evolution and the complications of the patients that survived cardiac wounds, attended at the Pronto-Socorro Municipal 28 de Agosto and Hospital Pronto-Socorro Dr. João Lúcio Pereira Machado, in Manaus, during the period of January 1998 until June 2006. Methods: A medical records evaluation was made among the patients attended at the two emergency hospitals in which a cardiac wound was found during a exploring thoracotomy. The survivors that returned to the ambulatory were evaluated prospectively through electrocardiogram and echocardiogram, so it was possible to analyze the morphology and the function of the heart. A protocol was filled out with a registry of patients data, such as: age, sex, trauma mechanism, intra-operative and post-operative complications, and other variables. Results: The total reference population in this study was 100 patients, in which 95% were male, the majority (69%) had ages until 30; 81% of the lesions were caused by stab wounds; 78% of the orifice of entry were located at the precordium; 41% of the lesions wounded the right ventricle and 38% wounded the left ventricle; In 48% of the cases a left antero-lateral thoracotomy was executed. The survival rate was 72%. The studied population was of 25 patients that returned to the ambulatory and were prospectively evaluated with electrocardiogram and echocardiogram. Among the 33 echocardiogram alterations (ECO), seven patients (28%) had mitral insufficiency, while nine (36%) didn\'t have any alterations. Among the 45 electrocardiogram alterations (ECG), eight patients (32%) had sinusal tachicardia, while six (24%) had no alterations. Time made no difference in the results of the ECO (p=0,5323) or of the ECG (p=0,6596). Of the 14 detected ECO complications, three (21,4%) were due to IV degree lesions in the right ventricle and eleven (78,7%) were due to V degree lesions (in the left ventricle) (p=0,048). From the 12 left ventricle lesions that complicated (ECG), 9 were V degree. From the 12 alterations detected at the ECG, three (25%) were due to IV degree lesions and nine (75%) were due to V degree lesions (p=0,226). Conclusions: Approximately one third of the cardiac wound survivors did not have alterations in the electrocardiogram and echocardiogram. Left ventricle and V degree lesions from the OIS-AAST were related to a larger number of alterations in the electrocardiogram and echocardiogram. Sinusal Tachicardia and mitral insuficiency were alterations found in one third of the patients that survived a cardiac wound.
15

Currarino-Silverman Syndrome (Pectus Carinatum Type 2 Deformity) and Mitral Valve Disease

Chidambaram, B, Mehta, A. V. 01 September 1992 (has links)
Currarino-Silverman syndrome is a rare disorder characterized by premature fusion of manubrio-sternal joint and the sternal segments, resulting in a high carinate chest deformity; it is frequently associated with congenital heart disease. Among the various heart lesions reported in this syndrome, mitral valve disease and coarctation of the aorta have not yet been described (to our knowledge). Our report consists of five children with this syndrome, four of whom had mitral valve disease, with an associated coarctation of the aorta in one patient. The fifth patient had an innocent heart murmur.
16

Avaliação pré e pós-operatória, através de ressonância magnética cardiovascular, de pacientes com insuficiência da valva mitral submetidos à plástica mitral pela técnica do duplo teflon / Preoperative and postoperative evaluation, by cardiovascular magnetic resonance, of patients with mitral valve insufficiency submitted to mitral valve repair using the double teflon technique

Abdouni, Ahmad Ali 21 January 2019 (has links)
Introdução: A plástica valvar mitral é o tratamento de escolha no tratamento da insuficiência mitral de etiologia degenerativa. Estudos recentes têm demonstrado que a utilização de anéis protéticos na plástica mitral altera a dinâmica do anel mitral e do fluxo intraventricular, podendo levar a disfunção ventricular esquerda. Entretanto, a literatura é escassa em relação à morfologia e à dinâmica do anel mitral após a plástica mitral sem a utilização de anéis protéticos, e a ressonância magnética cardiovascular (RMC) é uma ferramenta que pode ser utilizada na avaliação do anel mitral e do remodelamento do átrio e do ventrículo esquerdo. Objetivo: Avaliar as alterações morfofuncionais, a dinâmica do anel mitral e o remodelamento do átrio e ventrículo esquerdo, por meio da RMC, em indivíduos portadores de insuficiência mitral de etiologia degenerativa, submetidos ao tratamento cirúrgico da valva mitral com a técnica do \"Duplo Teflon\". Métodos: No período de julho de 2014 a agosto de 2016, foram selecionados 36 pacientes consecutivos, com insuficiência mitral de etiologia degenerativa e prolapso da cúspide posterior. Três pacientes foram submetidos à troca valvar mitral e quatro não realizaram a RMC, de modo que 29 pacientes foram incluídos no protocolo e fizeram o seguimento proposto. Destes, 17 pacientes eram do sexo masculino (58,6%) e 12 do sexo feminino (41,4%), com idade média de 63,3 anos. Em relação à classe funcional (CF - NYHA), um paciente encontrava-se em CF I (3,4%), 5 pacientes em CF II (17,3%), 19 pacientes em CF III (65,5%) e 4 pacientes em CF IV (13,8%) no período pré-operatório. Os pacientes realizaram o exame de RMC no período pré-operatório, pós-operatório imediato (até 30 dias), 6 meses, um ano e dois anos após a cirurgia, utilizando um protocolo específico para avaliação da valva mitral. Foram obtidas as medidas da circunferência, dos diâmetros e da área do anel mitral em diferentes fases do ciclo cardíaco (diástole, sístole inicial, sístole média e sístole final). Foi analisado o remodelamento cardíaco, sendo utilizados como parâmetros as dimensões, volumes e fração de ejeção do átrio esquerdo e do ventrículo esquerdo, sendo os volumes indexados pela superfície corpórea. Utilizamos o teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante P < 0,05. Resultados: Houve um óbito hospitalar (3,4%). Com dois anos de seguimento, houve significativa melhora da classe funcional (CF), com 18 pacientes em CF I (75%) e 6 em CF II (25%). Após dois anos, 18 pacientes apresentam insuficiência mitral discreta ou ausente (75%) e dois pacientes (8,3%) apresentam insuficiência mitral importante, um deles relacionado ao implante de marcapasso no pós-operatório tardio. Observamos uma redução significativa em todas as medidas da valva mitral. A média da circunferência sistólica do anel mitral foi reduzida de 13,28 ± 1,95 para 11,5 ± 1,59 cm e a circunferência diastólica foi reduzida de 12,51 ± 2,01 para 10,66 ± 2,09 cm no período pós-operatório imediato, medidas que se mantiveram estáveis após 2 anos (P < 0,001). A média da área máxima do anel mitral no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos foi 14,34 ± 4,03 cm, 10,72 ± 2,81 cm, 10,92 ± 3,03 cm, 10,98 ± 3,45 cm, 10,45 ± 3,17 cm, respectivamente. A média da área mínima do anel mitral no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos foi de 12,53 ± 3,68 cm2, 9,60 ± 2,44 cm2, 9,66 ± 2,9 cm2, 9,60 ± 3,73 cm2 , 9,23 ± 2,84 cm2, respectivamente. Houve uma redução significativa desses parâmetros no seguimento de dois anos (p < 0,001), e essa redução foi maior no diâmetro ântero-posterior do que no diâmetro médio-lateral. A contração ou variação da área valvar mitral durante o ciclo cardíaco foi de 23,31 ± 9,04%, 19,63 ± 7,01%, 23,75 ± 8,09%, 25,75 ± 11,27%, 22,66 ± 9,77% respectivamente no pré-operatório, pós-operatório imediato, 6 meses, 1 ano e 2 anos, sem diferença estatística (p = 0,572), o que significa que a contratilidade do anel foi preservada após a cirurgia. Observamos redução dos volumes ventriculares e atriais esquerdos no seguimento, sendo mais significativa a redução do índice do volume diastólico final do ventrículo esquerdo. Conclusão: Observamos uma redução significativa do anel mitral após a cirurgia, em todas as medidas obtidas, com estabilidade da plástica mitral em 2 anos de seguimento e preservação da contração dinâmica do anel neste período / Introduction: Mitral valve repair is the treatment of choice for mitral regurgitation of degenerative etiology. Recent studies have shown that the use of prosthetic rings in mitral valve repair alters the dynamics of the mitral annulus and intraventricular flow, which may lead to left ventricular dysfunction. However, the literature is scarce in relation to the morphology and dynamics of the mitral annulus after mitral repair without the use of prosthetic rings, and cardiovascular magnetic resonance (CMR) is a tool that can be used in the evaluation of the mitral annulus and the remodeling of the left atrium and left ventricle. Objective: To evaluate the morphological changes and the dynamics of the mitral valve and the remodeling of the left atrium and left ventricle, by CMR, in patients with mitral insufficiency of degenerative etiology who underwent mitral valve surgery with the Double Teflon technique. Methods: From July 2014 to August 2016, 36 consecutive patients with mitral insufficiency of degenerative etiology and prolapse of the posterior leaflet were selected. Three patients underwent mitral valve replacement and four did not perform the CMR, so that 29 patients were included in the protocol and did the proposed follow-up. Of these, 17 patients were male (58.6%) and 12 were female (41.4%), with a mean age of 63.3 years. In relation to functional class (NYHA), one patient was in Class I (3.4%), 5 patients in Class II (17.3%), 19 patients in Class III (65.5%) and 4 patients in Class IV (13.8%) in the preoperative period. Patients underwent CMR examination in the preoperative period, immediate postoperative (up to 30 days), 6 months, one year and two years after surgery, using a specific protocol for mitral valve evaluation. Measurements of the circumference, diameters and mitral ring area were obtained in different phases of the cardiac cycle (diastole, initial systole, mean systole and final systole). Cardiac remodeling was analyzed, and the dimensions, volumes and ejection fraction of the left atrium and left ventricle were used as parameters, and the volumes were indexed by the body surface. We used the analysis of variance of repeated measures for the statistical analysis, being considered statistically significant P < 0.05. Results: There was one hospital death (3,4%). After two years of follow-up, there was a significant improvement in functional class, with 18 patients in Class I (75%) and 6 in Class II (25%). After two years, 18 patients had mild or absent mitral insufficiency (75%) and two patients (8.3%) had important mitral regurgitation, one of them related to late postoperative pacemaker implantation. We observed a significant reduction in all measures of the mitral valve. The mean systolic circumference of the mitral annulus was reduced from 13.28 ± 1.95 to 11.5 ± 1.59 cm and the diastolic circumference was reduced from 12.51 ± 2.01 to 10.66 ± 2.09 cm in the immediate postoperative period, measures that remained stable after 2 years (P < 0.001). The mean maximal area of the mitral annulus in the preoperative, immediate postoperative, 6 months, 1 year and 2 years was 14.34 ± 4.03 cm, 10.72 ± 2.81 cm, 10.92 ± 3,03 cm, 10.98 ± 3.45 cm, 10.45 ± 3.17 cm, respectively. The mean minimal area of the mitral annulus in the preoperative, immediate postoperative, 6 months, 1 year and 2 years was 12.53 ± 3.68 cm2, 9.60 ± 2.44 cm2, 9.66 ± 2.9 cm2, 9.60 ± 3.73 cm2, 9.23 ± 2.84 cm2, respectively. There was a significant reduction of these parameters at two-year follow-up (p < 0.001), and this reduction was greater in the antero-posterior diameter than in the midlateral diameter. The contraction or variation of the mitral valve area during the cardiac cycle was 23.31 ± 9.04%, 19.63 ± 7.01%, 23.75 ± 8.09%, 25.75 ± 11.27%, 22.66 ± 9.77% respectively in the preoperative, postoperative, 6 months, 1 year and 2 years, without statistical difference (p = 0.572), which means that the contractility of the ring was preserved after surgery. We observed reduction of left ventricular and left atrial volumes in the follow-up, being more significant the reduction of the left ventricle end-diastolic volume index. Conclusion: We observed a significant reduction of the mitral annulus after surgery, in all the measurements obtained, with stability of the mitral repair in 2 years of follow-up and preservation of the dynamic contraction of the ring in this period
17

Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon technique

Guedes, Marco Antonio Vieira 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
18

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Pinto, Nathali Cordeiro 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy
19

Análise morfofuncional cardíaca com o uso da ecocardiografia tridimensional em tempo real em indivíduos submetidos à plastia valvar mitral pela técnica de duplo teflon / Cardiac morphologic and functional analysis using real time tridimensional echocardiography in individuals submitted to mitral valve repair by double teflon technique

Marco Antonio Vieira Guedes 17 August 2010 (has links)
INTRODUÇÃO: A plastia valvar mitral é o tratamento de escolha para a correção da insuficiência mitral mixomatosa. Estudos ecocardiográficos tridimensionais demonstram que a plastia mitral com implante de anéis protéticos altera a morfologia e a função do anel valvar mitral, porém a literatura é escassa em relação ao comportamento do anel mitral após a plastia mitral sem utilização de anéis protéticos. OBJETIVO: Analisar a morfologia e a função cardíaca de indivíduos submetidos à plastia valvar mitral pela técnica de Duplo Teflon, através da ecocardiografia tridimensional em tempo real. CASUÍSTICA: Foram incluídos 14 pacientes portadores de insuficiência mitral secundária a degeneração mixomatosa, que foram submetidos à plastia valvar mitral pela técnica de Duplo Teflon. Destes, 10 pacientes eram do sexo masculino e a idade média foi de 61,3 ± 11,2 anos. Em relação à classe funcional, 13 pacientes encontravam-se em classe III ou IV no período pré-operatório. Na análise ecocardiográfica pré-operatória, o valor médio do volume diastólico final do ventrículo esquerdo foi 156,57 ± 46,61ml, e a fração de ejeção do ventrículo esquerdo variou de 38 a 68%, com média de 57,93 ± 6,67%. O valor médio do anel mitral posterior foi 6,97 ± 0,13 cm. MÉTODOS: Os pacientes foram avaliados nos períodos pré-operatório, pós-operatório imediato (POI), 6 meses e 1 ano após a plastia mitral. A ecocardiografia tridimensional avaliou a morfologia do anel mitral através das medidas do anel anterior e posterior, dos diâmetros transversos e da área valvar. A função anular foi avaliada pela relação entre as áreas valvares internas durante a sístole e diástole. Foram avaliados os volumes e a função do átrio e do ventrículo esquerdos. Foi utilizado teste de análise de variância de medidas repetidas para o estudo estatístico, sendo considerado estatisticamente significante p < 0,05. RESULTADOS: O anel mitral posterior demonstrou uma redução significativa (p<0,001) no POI, que manteve-se estável durante o estudo. Não houve variação significativa na área valvar durante o estudo. Houve uma redução significativa nos diâmetros ântero-posterior e médio-lateral no POI (p<0,001), porém houve um aumento significativo no diâmetro médio-lateral entre POI e 1 ano. A fração de variação do anel mitral durante o ciclo cardíaco, ao longo do estudo, variou entre 30,92 e 35,75%, não havendo diferença estatisticamente significante. A análise dos volumes sistólicos, atrial e ventricular, demonstrou uma redução volumétrica significativa entre POI e 1 ano (p=0,028 e p=0,020, respectivamente). Entre o pré-operatório e 1 ano, houve uma redução média de 19,9% e 15,4% nos volumes atrial e ventricular, respectivamente. Os volumes diastólicos atrial e ventricular apresentaram uma redução significativa no POI (p<0,001 e p=0,024, respectivamente), permanecendo estáveis ao longo do estudo. Houve aumento na fração de ejeção do átrio esquerdo após 6 meses (p<0,001), porém não houve variação na função ventricular esquerda. CONCLUSÕES: A plastia mitral com a anuloplastia segmentar pela técnica do Duplo Teflon reduziu o anel posterior da valva mitral, que permaneceu estável no período de um ano. A variação da área anular mitral durante o ciclo cardíaco permaneceu estável durante o estudo. Além disso, houve um remodelamento reverso atrial e ventricular esquerdo, associado à melhora na função do átrio esquerdo / INTRODUCTION: Mitral valve repair is the treatment of choice to correct mixomatous mitral insufficiency. Tridimensional echocardiography studies demonstrate that mitral repair using prosthetic ring implant modifies mitral valve annulus morphology and function, although the literature related to mitral valve annulus behavior after mitral repair without use of prosthetic rings is scarce. OBJECTIVE: Analyze cardiac morphology and function using real time tridimensional echocardiography in individuals submitted to mitral valve repair with Double Teflon technique. CASUISTIC: Were included 14 patients with mitral valve insufficiency secondary to mixomatous degeneration that were submitted to mitral valve repair with the Double Teflon technique. Of them, 10 patients were male and the mean age was 61.3 ± 11.2 years. According to preoperatively functional class, 13 patients were in class III or IV. In preoperative echocardiographic analysis, the mean value of left ventricle end diastolic volume was 156.57 ± 46.61ml, and the left ventricle ejection fraction ranged between 38 and 68%, with average of 57.93 ± 6.67%. The mean value of the posterior annulus was 6.97 ± 0.13 cm. METHODS: Patients were evaluated in preoperative period, immediate postoperative period, 6 months and 1 year after mitral repair. Tridimensional echocardiography evaluated mitral annulus morphology by anterior and posterior measurements, transverse diameters and valve area. The annular function was evaluated through the ratio between internal valve areas during systole and diastole. Were evaluated left atrial and ventricle volumes and function. Statistic analysis was made by repeated measures ANOVA test and was considered statistically significant p < 0.05. RESULTS: Posterior mitral annulus demonstrated a significant reduction in immediate postoperative period (p<0.001), remaining stable during the study. There was no significant variation in valve area during the study. There was a significant reduction in anteroposterior and mediolateral diameters in the immediate postoperative period (p<0.001), although there was a significant increase in mediolateral diameter between immediate postoperative period and 1 year. Annular area variation over the cardiac cycle during the study ranged between 30.92 and 35.75%, without statistic significance. The analysis of systolic volumes, atrial and ventricular, demonstrated a significant volumetric reduction between immediate postoperative period and 1 year (p=0.028 and p=0.020, respectively). Between preoperative period and 1 year, there was a mean reduction in atrial and ventricle volumes of 19.9% and 15.4%, respectively. Atrial and ventricle diastolic volumes presented a significant reduction in immediate postoperative period (p<0.001 and p=0.024, respectively), remaining stable during the study. There was an increase in left atrial ejection fraction after 6 months (p<0.001), although there was no significant variation in left ventricle ejection fraction. CONCLUSIONS: Mitral valve repair with segmentar annuloplasty with the Double Teflon technique reduced the posterior mitral annulus, which remained stable in 1 year period. The variation in mitral annulus area during cardiac cycle remained stable during the study. Furthermore, there was a left atrial and ventricle reverse remodeling, associated with an improvement in left atrial function
20

Análise do efeito do laser de alta potência em valvas mitrais cardíacas de suínos: estudo experimental / Analysis of high power laser effect in swine cardiac mitral valves: experimental study

Nathali Cordeiro Pinto 10 July 2014 (has links)
Introdução e Objetivo: No Brasil, procedimentos valvares representam no mínimo 30% das cirurgias cardíacas realizadas no país. Em nosso meio ainda predominam as lesões valvares decorrentes da febre reumática e doenças degenerativas. Nos pacientes reumáticos, a valva mitral é a mais acometida, predominando a estenose devido à fusão comissural e lesões no plano subvalvar; porém espessamento e retração de cúspides também são comuns, determinando dupla lesão ou insuficiência desta valva. Em processos degenerativos, as cordas tendíneas podem se apresentar alongadas. Na tentativa de utilização futura do laser como método auxiliar na correção cirúrgica dessas valvopatias, iniciamos estudo experimental com o objetivo de comparar histologicamente o tecido valvar mitral de suínos (cordas tendíneas e cúspides) submetido com e sem o laser de alta potência (LAP). Métodos: Foram estudadas cordas tendíneas e cúspides mitrais de suínos jovens e saudáveis, divididos em 6 grupos: G1-Aplicação do laser em cordas tendíneas com o tempo de 15 s; G2- Aplicação do laser em cordas tendíneas com o tempo de 20 s; G3- Aplicação do laser em cordas tendíneas com o tempo de 30 s; G4- Grupo controle relacionado a G1, G2 e G3; G5- Grupo cúspide submetido a corte com lâmina de bisturi; G6- Grupo cúspide submetido a corte com laser. As cordas tendíneas dos grupos G1, G2 e G3 receberam tratamento com laser de diodo (=980 nm, P=3,0 W) e o grupo G6 com laser de diodo em outros parâmetros (=980 nm, P=9,0 W, T=12s). Termografia e tomografia por coerência óptica foram utilizadas durante o experimento. Parte da amostra foi preservada em formaldeído e glutaraldeído para análise microscópica e a outra parte foi preservada em solução fisiológica 0,9% para análise mecânica. Resultados: Houve um decréscimo significante no comprimento das cordas tendíneas após aplicação do laser quando comparado ao comprimento inicial (p=0,005 em G1 e G2 e p=0,004 em G3). À microscopia óptica, G1, G2 e G3 apresentaram áreas hialinas ocupando quase a totalidade da espessura da corda, quando coradas pela Hematoxilina-Eosina (HE), áreas vermelho-escura na região central da corda quando coradas pelo Tricrômico de Masson e áreas com birrefringência diminuída quando coradas pelo Picrosírius vermelho. Na avaliação mecânica, os grupos lasers apresentaram diminuição da rigidez do material, assim como na força máxima durante a ruptura, entretanto o deslocamento foi maior em relação ao grupo controle (p=0,005). No G5, evidenciamos ausência de qualquer alteração histológica. No G6 foram identificadas áreas de menor birrefringência do colágeno quando corado pelo Picrosírius vermelho, áreas estas que apresentavam aspecto basofilico hialino no HE e coloração vermelho-escura ao Tricrômico de Masson. Conclusão: As cordas tendíneas de valvas mitrais de suínos submetidas ao laser de alta potência apresentaram redução do seu comprimento final, diminuição na birrefringência e alteração na distribuição dos feixes de colágeno. Além disso, apresentaram queda da rigidez, maior fragilidade de rotura e maior deslocamento ao teste de tração mecânica quando comparada ao grupo controle. Com relação às cúspides, os danos térmicos encontrados no grupo corte com laser de alta potência foram maiores do que em relação ao bisturi de lâmina, quando evidenciados pela microscopia óptica / Introduction and Objective: In Brazil, valvar procedures represent at least 30% of cardiac surgeries performed in the country. It still predominate valvar lesions resulting from rheumatic fever and degenerative diseases. In rheumatic patients, the mitral valve is the most affected, predominantly stenosis due to commissural fusion and lesions in the subvalvar plane, however, thickening and retraction of the leaflets are also common, causing double lesion or mitral insufficiency. In degenerative process, the chordae tendineae may present elongated. In an attempt to further use of the laser as an auxiliary method in the surgical correction of valvar heart disease, we started experimental study with the purpose of comparing the histological swine tissue mitral valve (chordae tendineae and cusps) with and without high-power laser (HPL) application. Methods: Normal porcine mitral valve chordae and cups were studied and divided randomly into the following 6 groups: G1- Laser in the chordae tendineae with time of 15s; G2- Laser in the chordae tendineae with time of 20s; G3- Laser in the chordae tendineae with time of 30s; G4- Control Group; G5- Cusp group cut with a scalpel blade; G6- Cusp group cut with laser. Chordae tendineae from G1, G2 e G3 received diode laser (=980 nm, P=3,0 W) and G6 diode laser with other parameters (=980 nm, P=9,0 W, T=12s). Termography and optical coherence tomography were included during the procedure. Part of the sample was preserved in formaldehyde and glutaraldehyde for microscopic analysis and another part was stored in 0.9% saline for mechanical analysis. Results: There was a significant decrease in chordae length after laser application when compared to the initial length (p=0,005 to G1 and G2; p=0,004 to G3). In laser groups, histological analysis revealed a typical hyaline areas occupying almost the entire thickness of the chordae, when stained with Hematoxylin-Eosin (HE); dark red central areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius red. In mechanical analysis, we found lower stiffness, maximum rupture force decrease and larger displacement compared with the Control Group (p=0,005). In G5, was evidenced absence of any histological abnormality and a homogeneous blue appearance, typical of the cusp. However in G6, a basophilic hyaline aspect was found focally when stained with HE, dark red areas when stained with Masson Trichrome and a birefringence decrease when stained with Picrocirius Red. Conclusion: Chordae tendineae of normal porcine submitted to a high-power laser presented with reduced length, birefringence decrease and the collagen bundles organized into different orientations. Besides, presented lower stiffness, maximum rupture force decrease and larger displacement compared with the control group. Regarding cups, thermal changes were bigger in the cusp group cut with laser compared cusp group cut with scalpel blade, observed by optical microscopy

Page generated in 0.5009 seconds