• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 10
  • 3
  • 1
  • Tagged with
  • 204
  • 114
  • 52
  • 51
  • 49
  • 44
  • 37
  • 35
  • 31
  • 30
  • 29
  • 28
  • 28
  • 26
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Estudo sobre determinação de elementos químicos em unhas humanas pelo método de análise por ativação com nêutrons / A study on chemical element determinations in human nails by neutron activation analysis

Sanches, Thalita Pinheiro 17 August 2012 (has links)
As análises de unhas têm sido objeto de estudo para avaliar os níveis de elementos acumulados no organismo humano e com aplicações deste tecido na monitoração da exposição ocupacional ou ambiental, na avaliação do estado nutricional, na identificação da intoxicação por metais tóxicos e na diagnose ou prevenção de doenças. As análises de unhas apresentam vantagens devido à facilidade na coleta, estocagem e transporte das amostras bem como fornecem os níveis de elementos acumulados ao longo de um período de aproximadamente 6 meses ao contrário dos fluídos como sangue e urina. Entretanto há controvérsias sobre a aplicação dos dados de suas análises devido às dificuldades em estabelecer valores confiáveis de referência ou faixas de concentrações para uso como dados de controle. O objetivo deste trabalho foi avaliar os fatores que podem afetar nas concentrações de elementos nas unhas para posterior análise de amostras de um grupo de indivíduos aplicando o método de análise por ativação com nêutrons (NAA). As amostras de unhas das mãos e dos pés coletadas de indivíduos adultos de ambos os sexos, com idades de 18 a 71 anos e residentes na região metropolitana de São Paulo foram cortadas em pequenos fragmentos, lavadas e secas para as análises. O procedimento experimental consistiu em irradiar amostras juntamente com os padrões sintéticos de elementos por 16 h sob fluxo de nêutrons térmicos de cerca de 4,5 x 1012 n cm-2 s-1 do reator nuclear de pesquisa IEA-R1, seguido de espectrometria de raios gama para a determinação dos elementos As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se e Zn. No controle da qualidade analítica foram analisados os materiais de referência certificados cujos os resultados obtidos indicaram boa exatidão e precisão com erros relativos e desvios padrão relativos inferiores a 5,1 % e 11,6 % respectivamente. Os ensaios preliminares indicaram que as contribuições devido às impurezas presentes nos invólucros de plástico utilizados na irradiação assim como aquelas decorrentes da adsorção dos esmaltes nas unhas são muito baixas, podendo ser desprezadas. Nos testes de limpeza das unhas para análise foi verificado que a solução diluída de HNO3 pode provocar a dissolução das amostras. A homogeneidade da amostra preparada foi verificada pelas analises em réplicas. A comparação entre as concentrações de elementos obtidos nas unhas das mãos e dos pés indicou diferenças significativas para os elementos Br, Co e Zn (teste t, p = 0,05). As concentrações de elementos nas unhas quando comparadas em relação ao gênero, faixa etária e Índice de massa corpórea (IMC) dos indivíduos não apresentaram diferenças significativas para a maioria dos elementos determinados. A diferença significativa das concentrações de Zn das unhas das mãos foi verificada entre o gênero dos indivíduos e das concentrações de Cs entre às faixas etárias distintas. As concentrações de elementos obtidas nas unhas dos pés e das mãos apresentaram uma ampla variabilidade e para a maioria dos elementos os dados obtidos são da mesma ordem de grandeza ou dentro das faixas dos valores da literatura. / Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the São Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 1012 n cm-2 s-1 at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO3 solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in replicate. A comparison of finger and toenail results indicated significant differences (p= 0.05) for the elements Br, Co and Zn. Element concentration comparisons were also made with gender, age and body mass index (BMI) parameters and for the most part showed no significant differences. The differences were found for Zn concentrations when compared between genders in fingernail, for Cs when compared between ages in fingernail. Elements concentrations obtained for both finger and toenail samples presented wide variability and they were of the same order of magnitude or within ranges as those reported in published literature.
62

Estudos microdosimétricos usando um sistema de irradiação de nêutrons rápidos filtrados de reator de pesquisa para aplicação de radiobiologia / Microdosimetric studies using a filtered fast neutron irradiation system of research reactor to application in radiation biology

Rodrigues, Pedro Pereira 14 June 2007 (has links)
Neste trabalho, medidas microdosimétricas foram realizadas usando um contador proporcional equivalente à tecido - TEPC. com uma cavidade esférica de diâmetro de 1.27 cm. O TEPC foi preenchido com gás propane puro, C3HS, à pressão de 5,6 kPa (42 Torr), que é equivalente a 1,3 μm em diâmetro de unidade de densidade do tecido. O instrumento de medida microdosimétrica foi irradiado com radiação de nêutrons rápidos do reator de pequisa do Nuclear Science Center da Texas A&M University, em College Station,-Texas. Os feixes de nêutrons rápidos foram emitidos com três diferentes valores de potência. 0,5, 1,0, e 2,0 kVV, durante 1 hora para alto ganho e o mesmo tempo para baixo ganho, totalizando 2 horas para cada potência, com 0,0083 Gy/min de taxa de dose. O neutron foi filtrado usando o sistema de irradiação de néutrons rápidos fortemente nitrados (FNIS). do Nuclear Science Center, para obter uma redução da contaminação da radiação de neutron por radiação gama e assim obter espectros microdosimetricos de neutrons como, distribuição de freqüência de energia lineal e distribuição de dose de energia lineal, com boa precisão, e outras grandezas como, freqüência média de energia lineal, dose média de energia lineal, dose absorvida, dose equivalente e fator de qualidade médio de neutron rápido. Os resultados obtidos foram satisfatórios, com os espectros microdosimetricos de nêutrons mostrando uma contaminação de radiação gama abaixo de 5 %, especialmente para distribuição de dose de energia lineal. Os resultados obtidos neste trabalho foram comparados com outros da literatura científica, que usaram outros procedimentos para a redução da contaminação do neutron por radiação gama. estando em concordância com eles. / In this work, microdosimetric measurements were performed using a Wall-less Tissue Equivalent Proportional Counter - TEPC was filled with spherical cavity with an inner diameter of 1.27 cm. The TEPC was tilled with pure propane gas, C3H8 at 5.6 kPa (42 Torr) pressure, which is equi\\alent to 1.3μm in diameter of unit density tissue. The microdosimetric measurement device was irradiated with fast neutron radiation from Texas A&M University Nuclear Science Center research reactor, in College Station, Texas. The fast neutron beams were emitted with three different power values, 0.5, 1.0 and 2.0 kW. during Ih for both high gain and low gain, totalizing two hours for each power with 0.0083 Gy/min of dose rate. The neutron was filtered using the heavily filtered fast neutron irradiation s\\stem (FNIS). from Nuclear Science Center, to obtain a decrease of neutron radiation contamination by gamma ray and so, to gain the neutron microdosimetric spectra as. frequency distribution of lineal energy, dose distribution of lineal energy with good precision, and another quantities as frequency-mean of lineal energy, dose- mean of lineal energy, absorbed dose, equivalent dose and average quality factor of fast neutron. The obtained results were satisfactory, with the neutron microdosimetric spectra showing a gamma ray contamination under 5 %, especially to dose distribution of lineal energy. The results obtained in this work were in agreement when compared with another results from scientific literature, which used another procedure to reduce the neutron contamination by gamma ray.
63

Estabelecimento e caracterização de um laboratório de calibração com campos neutrônicos de referência com rastreabilidade ao sistema metrológico internacional / Establishment and characterization of a calibration laboratory with reference neutron beams and traceability to the international metrology system

Alvarenga, Tallyson Sarmento 23 August 2018 (has links)
No Brasil, atualmente só há um laboratório de calibração de monitores de radiação de nêutrons, sendo responsável pela guarda e manutenção do padrão brasileiro da fluência de nêutrons, localizado no Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Rio de Janeiro, no Instituto de Radioproteção e Dosimetria, Comissão Nacional de Energia Nuclear, Rio de Janeiro, com uma demanda grande de serviços com esse tipo de radiação. Com o intuito de descentralizar a oferta de serviços de calibração, surgiu a necessidade da montagem de um segundo Laboratório de Calibração com Nêutrons (LCN), no IPEN. Nas situações práticas envolvendo a calibração de monitores de radiação de nêutrons, um dos problemas principais está relacionado à radiação espalhada, que pode variar dependendo das dimensões do laboratório usado nos procedimentos de calibração. No processo de caracterização do campo de radiação de nêutrons da fonte de 241AmBe, onde foi realizada a avaliação dos espectros, das energias, das taxas de fluência, das taxas de equivalente de dose ambiente [H*(10)] e do coeficiente de conversão de fluência em dose [h*φ(10)] em diferentes posições do LCN, utilizando o feixe completo. A influência da radiação espalhada foi determinada por meio de três técnicas: Métodos de Monte Carlo, de Ajuste Reduzido e do Cone de Sombra. Dos resultados obtidos por meio de simulação e experimentalmente foi possível obter a fração de espalhamento em diferentes distâncias fonte-detector. / In Brazil, there is currently only one calibration laboratory for neutron radiation monitors. It is responsible for the custody and maintenance of the Brazilian neutron fluence standard, located at the Laboratório Nacional de Metrologia das Radiações Ionizantes-LNMRI, Rio de Janeiro, at the Instituto de Radioproteção e Dosimetria, Comissão Nacional de Energia Nuclear, with a great demand of services with this type of radiation. In order to decentralize the calibration service offer, it was necessary to set up a second Neutron Calibration Laboratory (LCN), at IPEN. In practical situations involving the calibration of neutron radiation monitors, one of the main problems is related to scattered radiation, which may vary depending on the size of the laboratory used for the calibration procedures. In the process of characterization of the neutron radiation field of the 241AmBe source, the spectra, the energies, the fluence rate, the ambient dose equivalent rate and the conversion coefficient of fluence in dose at different positions of the LCN, were evaluated using the complete beam. The influence of the scattered radiation was determined by three techniques: Monte Carlo Method, the Reduced Adjustment Method and the Shade Cone Method. From the results obtained through simulation and experimentally, it was possible to obtain the scattering fraction at different source-detector distances.
64

Dosimetria termoluminescente de altas doses de raios gama, raios beta, feixe de prótons e de nêutrons epitérmicos utilizando minerais naturais de silicatos e dosímetros de LiF: Mg, Cu, P (MCP) / High-dose thermoluminescent dosimetry of gamma rays, beta rays, proton beams and epithermal neutrons using natural silicate minerals and LiF: Mg, Cu, P (MCP) detectors

Lucas Sátiro do Carmo 04 September 2015 (has links)
No mundo de hoje, onde o uso da radiação de diversas naturezas está generalizado, a quantificação da energia depositada por essas diferentes radiações se tornou uma atividade de grande importância, principalmente quando a faixa de energia é considerada elevada, estas altas energias de radiação estão presentes, geralmente, em aceleradores de partículas, reatores nucleares e em irradiadores industriais, por exemplo. Este trabalho tem como objetivo medir altas doses de radiação de raios gama, feixes de elétrons e feixes de prótons utilizando duas variedades de um silicato natural (água-marinha e goshenita) e medir altas doses de nêutrons epitérmicos de alta fluência utilizando dosímetros de Fluoreto de Lítio dopados com Mg, Cu e P (MCP). A técnica utilizada para medir a dose absorvida por esses materiais foi a termoluminescência. As irradiações com raios- γ provenientes de fontes de 60Co foram de 100 kGy a 2000 kGy para a água-marinha e de 600 kGy a 2000 kGy para a goshenita, os resultados de intensidade TL vs Dose mostram que a partir de certa dose - 250 kGy e 1234,8 kGy para água-marinha e goshenita, respectivamente - o sinal TL começa a decrescer. Foi observado neste trabalho que, estes materiais quando irradiados com tais doses e posteriormente irradiados com doses baixas de alguns Gys até cerca de 400-500 Gy, o sinal TL decresce regularmente, podendo ser utilizado na dosimetria das radiações nessa faixa de dose. Para a irradiação de feixe de prótons e de feixe de elétrons foram utilizados dosímetros em placa de goshenita e dosímetros de pastilhas de água-marinha, a carga do feixe de prótons vai de 20 a 216 μC e a dose do feixe de elétrons vai de 10 kGy a 70 kGy. As irradiações com nêutrons epitérmicos utilizando LiF: Mg, Cu, P foram realizadas no reator IEA-R1/IPEN com fluências de 1014 a 1017 n/cm² e a quantificação das doses absorvidas foram realizadas utilizando o método UHTR (Ultra High Temperature Ratio). / In the present days the usage of ionizing radiation from several different sources is spread all over the world. The measurement of the absorbed energy from these radiations became a very important task, mainly when the dose range is considered being in a very high level. These high energies of radiation are associated with particles accelerators, nuclear reactors and industrial irradiators, for example. This work is concerned for measuring high-doses of gamma radiation, electron beams and proton beams using two varieties of a natural silicate (aqua-marine and goshenite) and measuring effects of high-fluence neutrons using LiF: Mg, Cu, P (MCP) detectors. Thermoluminescence was employed to measure the absorbed dose for irradiations with gamma rays ranging from 100 kGy up to 2000 kGy for aquamarine and from 600 kGy and 2000 kGy for goshenite. The TL intensity reaches maximum at 250 kGy in aquamarine and at 1234 kGy for goshenite; this means that for doses larger than 250 kGy in aquamarine and 1234 kGy in goshenite the TL intensity drops. However, the descending part can be used in very high dose dosimetry. Furthermore, has been observed in this study that starting with aquamarine irradiated with 250 kGy and goshenite with 1234 kGy, the subsequent irradiation with doses from low to 400-500 Gy produces a regularly decreasing TL intensity, so that it can be used in radiation dosimetry from low to 400-500 Gy doses. For proton beams, goshenite were used. The beam charge ranges from 20 a 216 μC. For electron beams small pressed pellets of aquamarine were used. The dose ranges from 10 kGy to 70 kGy. The epithermal neutron irradiation was performed at IEA-R1 research reactor at IPEN and MCP-LiF detectors were used to measure the absorbed dose. A method called UHTR (Ultra High Temperature Ratio) was employed for calculating the amount of energy absorbed by the dosimeter. The fluence of epithermal neutrons ranges from 1014 a 1017 n/cm².
65

Estudos microdosimétricos usando um sistema de irradiação de nêutrons rápidos filtrados de reator de pesquisa para aplicação de radiobiologia / Microdosimetric studies using a filtered fast neutron irradiation system of research reactor to application in radiation biology

Pedro Pereira Rodrigues 14 June 2007 (has links)
Neste trabalho, medidas microdosimétricas foram realizadas usando um contador proporcional equivalente à tecido - TEPC. com uma cavidade esférica de diâmetro de 1.27 cm. O TEPC foi preenchido com gás propane puro, C3HS, à pressão de 5,6 kPa (42 Torr), que é equivalente a 1,3 μm em diâmetro de unidade de densidade do tecido. O instrumento de medida microdosimétrica foi irradiado com radiação de nêutrons rápidos do reator de pequisa do Nuclear Science Center da Texas A&M University, em College Station,-Texas. Os feixes de nêutrons rápidos foram emitidos com três diferentes valores de potência. 0,5, 1,0, e 2,0 kVV, durante 1 hora para alto ganho e o mesmo tempo para baixo ganho, totalizando 2 horas para cada potência, com 0,0083 Gy/min de taxa de dose. O neutron foi filtrado usando o sistema de irradiação de néutrons rápidos fortemente nitrados (FNIS). do Nuclear Science Center, para obter uma redução da contaminação da radiação de neutron por radiação gama e assim obter espectros microdosimetricos de neutrons como, distribuição de freqüência de energia lineal e distribuição de dose de energia lineal, com boa precisão, e outras grandezas como, freqüência média de energia lineal, dose média de energia lineal, dose absorvida, dose equivalente e fator de qualidade médio de neutron rápido. Os resultados obtidos foram satisfatórios, com os espectros microdosimetricos de nêutrons mostrando uma contaminação de radiação gama abaixo de 5 %, especialmente para distribuição de dose de energia lineal. Os resultados obtidos neste trabalho foram comparados com outros da literatura científica, que usaram outros procedimentos para a redução da contaminação do neutron por radiação gama. estando em concordância com eles. / In this work, microdosimetric measurements were performed using a Wall-less Tissue Equivalent Proportional Counter - TEPC was filled with spherical cavity with an inner diameter of 1.27 cm. The TEPC was tilled with pure propane gas, C3H8 at 5.6 kPa (42 Torr) pressure, which is equi\\alent to 1.3μm in diameter of unit density tissue. The microdosimetric measurement device was irradiated with fast neutron radiation from Texas A&M University Nuclear Science Center research reactor, in College Station, Texas. The fast neutron beams were emitted with three different power values, 0.5, 1.0 and 2.0 kW. during Ih for both high gain and low gain, totalizing two hours for each power with 0.0083 Gy/min of dose rate. The neutron was filtered using the heavily filtered fast neutron irradiation s\\stem (FNIS). from Nuclear Science Center, to obtain a decrease of neutron radiation contamination by gamma ray and so, to gain the neutron microdosimetric spectra as. frequency distribution of lineal energy, dose distribution of lineal energy with good precision, and another quantities as frequency-mean of lineal energy, dose- mean of lineal energy, absorbed dose, equivalent dose and average quality factor of fast neutron. The obtained results were satisfactory, with the neutron microdosimetric spectra showing a gamma ray contamination under 5 %, especially to dose distribution of lineal energy. The results obtained in this work were in agreement when compared with another results from scientific literature, which used another procedure to reduce the neutron contamination by gamma ray.
66

Estudo sobre determinação de elementos químicos em unhas humanas pelo método de análise por ativação com nêutrons / A study on chemical element determinations in human nails by neutron activation analysis

Thalita Pinheiro Sanches 17 August 2012 (has links)
As análises de unhas têm sido objeto de estudo para avaliar os níveis de elementos acumulados no organismo humano e com aplicações deste tecido na monitoração da exposição ocupacional ou ambiental, na avaliação do estado nutricional, na identificação da intoxicação por metais tóxicos e na diagnose ou prevenção de doenças. As análises de unhas apresentam vantagens devido à facilidade na coleta, estocagem e transporte das amostras bem como fornecem os níveis de elementos acumulados ao longo de um período de aproximadamente 6 meses ao contrário dos fluídos como sangue e urina. Entretanto há controvérsias sobre a aplicação dos dados de suas análises devido às dificuldades em estabelecer valores confiáveis de referência ou faixas de concentrações para uso como dados de controle. O objetivo deste trabalho foi avaliar os fatores que podem afetar nas concentrações de elementos nas unhas para posterior análise de amostras de um grupo de indivíduos aplicando o método de análise por ativação com nêutrons (NAA). As amostras de unhas das mãos e dos pés coletadas de indivíduos adultos de ambos os sexos, com idades de 18 a 71 anos e residentes na região metropolitana de São Paulo foram cortadas em pequenos fragmentos, lavadas e secas para as análises. O procedimento experimental consistiu em irradiar amostras juntamente com os padrões sintéticos de elementos por 16 h sob fluxo de nêutrons térmicos de cerca de 4,5 x 1012 n cm-2 s-1 do reator nuclear de pesquisa IEA-R1, seguido de espectrometria de raios gama para a determinação dos elementos As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se e Zn. No controle da qualidade analítica foram analisados os materiais de referência certificados cujos os resultados obtidos indicaram boa exatidão e precisão com erros relativos e desvios padrão relativos inferiores a 5,1 % e 11,6 % respectivamente. Os ensaios preliminares indicaram que as contribuições devido às impurezas presentes nos invólucros de plástico utilizados na irradiação assim como aquelas decorrentes da adsorção dos esmaltes nas unhas são muito baixas, podendo ser desprezadas. Nos testes de limpeza das unhas para análise foi verificado que a solução diluída de HNO3 pode provocar a dissolução das amostras. A homogeneidade da amostra preparada foi verificada pelas analises em réplicas. A comparação entre as concentrações de elementos obtidos nas unhas das mãos e dos pés indicou diferenças significativas para os elementos Br, Co e Zn (teste t, p = 0,05). As concentrações de elementos nas unhas quando comparadas em relação ao gênero, faixa etária e Índice de massa corpórea (IMC) dos indivíduos não apresentaram diferenças significativas para a maioria dos elementos determinados. A diferença significativa das concentrações de Zn das unhas das mãos foi verificada entre o gênero dos indivíduos e das concentrações de Cs entre às faixas etárias distintas. As concentrações de elementos obtidas nas unhas dos pés e das mãos apresentaram uma ampla variabilidade e para a maioria dos elementos os dados obtidos são da mesma ordem de grandeza ou dentro das faixas dos valores da literatura. / Nail analyses have been the object of study in order to assess the levels of elements accumulated in the human organism and to use this tissue to monitor environmental and occupational exposure, to evaluate the nutritional status, to verify intoxication by toxic metals and to diagnose or to prevent diseases. Nail analyses present advantages due to easy sample collection, storage, transportation and this tissue provides element level accumulation over time. However, there is controversy regarding the application of nail analysis data due to difficulties to establish reliable reference values or element concentration ranges as control values. The objective of this study was to evaluate the factors that can affect nail element concentrations for further sample analyses of a group of individuals by applying neutron activation analysis (NAA). Fingernails and toenails collected from adult individuals of both genders, aged 18 to 71 years, living in the São Paulo Metropolitan Region were cut in small fragments, cleaned and dried for analyses. Samples and element standards were irradiated for 16 h under a thermal neutron flux of about 4.5 x 1012 n cm-2 s-1 at the IEA-R1 nuclear research reactor followed by gamma ray spectrometry. Element concentrations for As, Br, Ca, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Se and Zn were determined. For quality control of the analytical results, certified reference materials were analysed and the results showed good accuracy and precision with relative errors and relative standard deviations lower than 5.1 % and 11.6 %, respectively. Preliminary assays indicated that the contribution due to impurities from plastic involucres used in the irradiation as well as those from nail polishes is very low and could be considered negligible. Results from the nail sample cleaning process using distinct procedures indicated that HNO3 solution may cause sample dissolution. Sample homogeneity was verified by analysis of a sample in replicate. A comparison of finger and toenail results indicated significant differences (p= 0.05) for the elements Br, Co and Zn. Element concentration comparisons were also made with gender, age and body mass index (BMI) parameters and for the most part showed no significant differences. The differences were found for Zn concentrations when compared between genders in fingernail, for Cs when compared between ages in fingernail. Elements concentrations obtained for both finger and toenail samples presented wide variability and they were of the same order of magnitude or within ranges as those reported in published literature.
67

Modelo para o índice de frenagem de pulsares

Heitor Oliveira de Oliveira 03 August 2015 (has links)
Pulsares são objetos astrofísicos normalmente modelados como estrelas de nêutrons compactas, tendo como origem o colapso de outra estrela. Em um modelo que chamaremos canônico, supõe-se que os pulsares são descritos por corpos extremamente massivos e esféricos que giram em torno de si mesmos, compostos por um dipolo magnético cujo o eixo magnético via de regra se encontra desalinhado com o eixo de rotação. Esse desalinhamento seria responsável pela observação de radiação emitida em intervalos de tempo bem definidos em uma dada orientação (efeito farol), que é a característica observacional típica desse tipo de estrela. Observa-se que a frequência de rotação dos pulsares está decaindo lentamente com o tempo (spin down), implicando uma redução gradativa da velocidade angular de rotação ($Omega$). Esse decaimento pode ser quantificado por um parâmetro adimensional denominado índice de frenagem ("n"; em inglês: braking index), dado por $ n = Omega ddot{Omega}/ dot{Omega}^2$, onde o ponto indica derivada com relação ao tempo. O modelo canônico prevê que este índice possui um valor único para todos os pulsares, igual a três. No entanto, dados observacionais indicam que índices de frenagem reais são inferiores a três, o que representa um enigma. O objetivo principal desta pesquisa é a exploração de um modelo mais preciso para o decaimento do período orbital de pulsares. A partir da configuração de irradiação eletromagnética da energia rotacional de uma estrela de nêutrons proposta por Thomas Gold em 1968 e que é base para o modelo canônico, demonstramos a influência da variação do tamanho de uma estrela de nêutrons, admitindo a variação do seu raio, sobre o índice de frenagem da mesma, a partir da proposta de um modelo teórico. Observamos que o índice de frenagem diminui à medida em que o raio da estrela aumenta, o que também implica um momento de inércia maior. Essa contribuição não altera a irradiação da energia dipolar magnética, mas reduz a velocidade angular da estrela e, portanto, a frequência dos pulsos luminosos do pulsar, conforme se observa.
68

Gluons em estrelas de nêutrons / Gluons in neutron Stars

Franzon, Bruno Cezar de Souza 03 April 2012 (has links)
O plasma de quarks e gluons (QGP) em temperatura zero e alta densidade bariônica é um sistema que pode existir no interior de estrelas densas. É possível que esse QGP frio compartilhe algumas características com o plasma quente, observado em colisões de íons pesados relativísticos, sendo também um sistema fortemente interagente. Neste trabalho, utilizamos uma equação de estado derivada a partir da QCD e a aplicamos no estudo de estrutura estelar. Mostramos que nossos resultados são compatíveis com o pulsar PSR J1614 2230 de massa (1.97 ± 0.04)M. / The Quark Gluon Plasma (QGP) at zero temperature and high baryon number is a system that may exist in the core of dense stars. This cold QGP has a rich phase structure and at high enough chemical potential it is quite possible that it shares some features with the hot QGP observed in heavy ion collisions, being also a strongly interacting system. We use an equation of state derived from QCD and apply it to study of stellar structure. Our results reproduce the measured mass, (1.97 ± 0.04)M, of the pulsar PSR J1614 2230.
69

Implementação do método k0-INAA no laboratório de análise por ativação com nêutrons do IPEN utilizando o programa k0-IAEA. Aplicação à análise de amostras geológicas / k0-NAA implementation and application at IPEN neutron activation laboratory by using the k0-IAEA software. Application to geological sample analysis

Mariano, Davi Brigatto 01 February 2012 (has links)
O Laboratório de Análise por Ativação com Nêutrons (LAN-IPEN) vem analisando amostras geológicas, tais como rochas, solos e sedimentos, há vários anos, empregando o método de análise por ativação com nêutrons comparativa, visando estudos geoquímicos e ambientais. Este trabalho apresenta os resultados obtidos na implementação do método de padronização k0-INAA no LANIPEN, para a análise de amostras geológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). A razão do fluxo de nêutrons térmico-epitérmico f e o fator &alpha; da distribuição de fluxo de nêutrons epitérmicos do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação, e em uma posição de irradiação selecionada, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr-94Zr. Para avaliar a exatidão e precisão do método, foram analisados os materiais geológicos de referência basalto JB-1 (GSJ) e BE-N (IWG-GIT), andesito AGV-1 (USGS), granito GS-N (ANRT), SOIL-7 (IAEA) e sedimento Buffalo River Sediment (NIST BRS-8704), que representam diferentes matrizes geológicas. Os resultados obtidos para até 30 elementos concordaram com os valores recomendados, com erros relativos (bias) menores que 10%, exceto no caso do Zn no AGV-1 (11,4%) e Mg no GS-N (13,4%). Os critérios estatísticos z-score, zeta-score e U-score foram aplicados para avaliação dos resultados. Pelo critério do z-score, os resultados obtidos puderam ser considerados satisfatórios (z<2), com exceção dos resultados obtidos para Mg no GS-N e no JB-1, e para Yb no Soil-7. O critério estatístico zeta-score se mostrou o mais restritivo, obtendo-se resultados questionáveis (2 < zeta < 3) para Mg no BE-N, Mn no GS-N e Yb no Soil-7, e resultados insatisfatórios (zeta>3) para Mn no BE-N, Mg, Ce e La no GS-N, Mg no JB-1, e Th e Eu no Buffalo River Sediment. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Mg no JB-1, estão dentro de um intervalo de confiança de 95% (se for considerado 1,96 o valor limite para o Uteste para um nível de probabilidade de 95%). Estes resultados indicam excelentes possibilidades para o uso deste método paramétrico no LAN-IPEN para a análise de amostras geológicas em estudos geoquímicos e ambientais. / The Neutron Activation Analysis Laboratory (LAN-IPEN) has been analysing geological samples such as rocks, soils and sediments, for many years with the INAA comparative method, for geochemical and environmental research. This study presents the results obtained in the implementation of the k0-standardization method at LANIPEN, for geological sample analysis, by using the program k0- IAEA, provided by the International Atomic Energy Agency (IAEA). The thermal to epithermal flux ratio f and the shape factor &alpha; of the epithermal flux distribution of the IPEN IEA-R1 nuclear reactor were determined for the pneumatic irradiation facility and one selected irradiation position, for short and long irradiations, respectively. To obtain these factors, the bare triple-monitor method with 197Au- 96Zr-94Zr was used. In order to validate the methodology, the geological reference materials basalts JB-1 (GSJ) and BE-N (IWG-GIT), andesite AGV-1 (USGS), granite GS-N (ANRT), SOIL-7 (IAEA) and sediment Buffalo River Sediment (NISTBRS-8704), which represent different geological matrices, were analysed. The concentration results obtained agreed with assigned values, with bias less than 10% except for Zn in AGV-1 (11.4%) and Mg in GS-N (13.4%). Three different scores were used to evaluate the results: z-score, zeta-score and Uscore. The z-score showed that the results can be considered satisfactory (z<2), except for Mg in GS-N and JB-1, and for Yb in Soil-7. Zeta-score was the most restrictive criterion, indicating questionable results (2 < zeta < 3) for Mg in BE-N, Mn in GS-N and Yb in Soil-7, and unsatisfactory results (zeta>3) for Mn in BE-N, Mg, Ce and La in GS-N, Mg in JB-1, and Th and Eu in Buffalo River Sediment. The U-score test showed that all results, except Mg in JB-1, were within 95% confidence interval. These results indicate excellent possibilities of using this parametric method at the LAN-IPEN for geological samples analysis in geochemical and environmental studies.
70

Qualidade ambiental de solos agrícolas da bacia do Rio Jaguari -São Paulo / ENVIRONMENTAL QUALITY OF AGRICULTURAL SOILS WITHIN THE JAGUARI RIVER BASIN - SÃO PAULO

Ruby, Elaine Cristina 26 November 2009 (has links)
Os impactos sobre o meio ambiente têm ocorrido de formas e intensidades variadas sobre os diferentes meios: solo, água e ar. Atualmente, diversos países utilizam critérios legais de proteção do solo, ou por meio de valores orientadores genéricos ou por meio de avaliação de risco caso a caso. No Brasil, em 2001, o Estado de São Paulo por meio da Companhia Ambiental (CETESB) foi pioneiro na publicação de valores orientadores para solos e águas subterrâneas. O objetivo desse trabalho foi avaliar a qualidade ambiental de solos agrícolas comparando-os com solos sob remanescentes e/ou fragmentos de mata, áreas-controle, na bacia do rio Jaguari - Estado de São Paulo tendo como base a legislação ambiental para o Estado de São Paulo. Esta avaliação ocorreu por meio da determinação de multielementos pela técnica de Análise por Ativação Neutrônica Instrumental-INAA, complementada pelas técnicas analíticas de Espectrometria Ótica de Emissão com Plasma de Argônio-ICP OES e Espectrometria de Absorção Atômica de Forno de grafite-GFAAS. Na comparação entre os resultados obtidos nas amostras de solo analisadas e os valores orientadores, constatou-se que não ocorreram concentrações medianas superiores aos valores de prevenção. Foi observado que para os elementos Sb, As, Cd, Pb, Co, Cu, Cr, Ni, V e Zn, as concentrações medianas ficaram abaixo dos valores de referência para o Estado de São Paulo, exceto para o Pb. Dos 34 elementos determinados, ocorreram diferenças estatisticamente significativas (p<0,05) entre os grupos, agrícola e mata, somente para os elementos Ba, As, U e V. Somente o Ba apresentou concentrações mais elevadas nos solos sob fragmentos de mata. Portanto, a qualidade ambiental dos solos agrícolas dessa bacia foi pouco alterada para os parâmetros determinados. Os elementos U e As podem ser utilizados como indicadores potenciais de contaminação em solos cultivados. / Environmental impacts have occurred in various forms and intensities on soil, water and air media. Consequently, several countries have used legal criteria for soil protection, either by means of generic guiding values or through case-by-case risk assessment. The São Paulo Environmental Agency (CETESB) pioneered the publication of guiding values for soils and groundwater in 2001. The aim of this study was to evaluate the environmental quality of agricultural soils in comparison to pristine soils (control areas) within the Jaguari river basin, São Paulo. The evaluation was carried out through multielement determination by Neutron Activation Analysis Instrumental (INAA) technique. The analyses were also complemented by Optical Emission Spectrometry Coupled Plasma (ICP OES), Atomic Absorption Spectrometry and Graphite Furnace (GFAAS) techniques. The results obtained in the analyzed soil samples were compared to the guiding values established by the São Paulo State environmental legislation and revealed that there were no median concentrations above the prevention values. The median concentrations for the elements Sb, As, Cd, Pb, Co, Cu, Cr, Ni, V and Zn were below the reference values, except for Pb. Taking into account the 34 elements determined, there were statistically significant differences (p <0.05) between agricultural and pristine soils only for the elements Ba, As, U and V. Among these elements, Ba presented the highest concentrations in pristine soils. It was concluded, that the environmental quality of agricultural soils within the Jaguari river basin - SP was slightly changed for the given parameters. The results also pointed out for the utilization of U and As as indicators of potential contamination in soils.

Page generated in 0.0433 seconds