• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 10
  • 3
  • 1
  • Tagged with
  • 204
  • 114
  • 52
  • 51
  • 49
  • 44
  • 37
  • 35
  • 31
  • 30
  • 29
  • 28
  • 28
  • 26
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Dosimetria termoluminescente de altas doses de raios gama, raios beta, feixe de prótons e de nêutrons epitérmicos utilizando minerais naturais de silicatos e dosímetros de LiF: Mg, Cu, P (MCP) / High-dose thermoluminescent dosimetry of gamma rays, beta rays, proton beams and epithermal neutrons using natural silicate minerals and LiF: Mg, Cu, P (MCP) detectors

Carmo, Lucas Sátiro do 04 September 2015 (has links)
No mundo de hoje, onde o uso da radiação de diversas naturezas está generalizado, a quantificação da energia depositada por essas diferentes radiações se tornou uma atividade de grande importância, principalmente quando a faixa de energia é considerada elevada, estas altas energias de radiação estão presentes, geralmente, em aceleradores de partículas, reatores nucleares e em irradiadores industriais, por exemplo. Este trabalho tem como objetivo medir altas doses de radiação de raios gama, feixes de elétrons e feixes de prótons utilizando duas variedades de um silicato natural (água-marinha e goshenita) e medir altas doses de nêutrons epitérmicos de alta fluência utilizando dosímetros de Fluoreto de Lítio dopados com Mg, Cu e P (MCP). A técnica utilizada para medir a dose absorvida por esses materiais foi a termoluminescência. As irradiações com raios- γ provenientes de fontes de 60Co foram de 100 kGy a 2000 kGy para a água-marinha e de 600 kGy a 2000 kGy para a goshenita, os resultados de intensidade TL vs Dose mostram que a partir de certa dose - 250 kGy e 1234,8 kGy para água-marinha e goshenita, respectivamente - o sinal TL começa a decrescer. Foi observado neste trabalho que, estes materiais quando irradiados com tais doses e posteriormente irradiados com doses baixas de alguns Gys até cerca de 400-500 Gy, o sinal TL decresce regularmente, podendo ser utilizado na dosimetria das radiações nessa faixa de dose. Para a irradiação de feixe de prótons e de feixe de elétrons foram utilizados dosímetros em placa de goshenita e dosímetros de pastilhas de água-marinha, a carga do feixe de prótons vai de 20 a 216 μC e a dose do feixe de elétrons vai de 10 kGy a 70 kGy. As irradiações com nêutrons epitérmicos utilizando LiF: Mg, Cu, P foram realizadas no reator IEA-R1/IPEN com fluências de 1014 a 1017 n/cm² e a quantificação das doses absorvidas foram realizadas utilizando o método UHTR (Ultra High Temperature Ratio). / In the present days the usage of ionizing radiation from several different sources is spread all over the world. The measurement of the absorbed energy from these radiations became a very important task, mainly when the dose range is considered being in a very high level. These high energies of radiation are associated with particles accelerators, nuclear reactors and industrial irradiators, for example. This work is concerned for measuring high-doses of gamma radiation, electron beams and proton beams using two varieties of a natural silicate (aqua-marine and goshenite) and measuring effects of high-fluence neutrons using LiF: Mg, Cu, P (MCP) detectors. Thermoluminescence was employed to measure the absorbed dose for irradiations with gamma rays ranging from 100 kGy up to 2000 kGy for aquamarine and from 600 kGy and 2000 kGy for goshenite. The TL intensity reaches maximum at 250 kGy in aquamarine and at 1234 kGy for goshenite; this means that for doses larger than 250 kGy in aquamarine and 1234 kGy in goshenite the TL intensity drops. However, the descending part can be used in very high dose dosimetry. Furthermore, has been observed in this study that starting with aquamarine irradiated with 250 kGy and goshenite with 1234 kGy, the subsequent irradiation with doses from low to 400-500 Gy produces a regularly decreasing TL intensity, so that it can be used in radiation dosimetry from low to 400-500 Gy doses. For proton beams, goshenite were used. The beam charge ranges from 20 a 216 μC. For electron beams small pressed pellets of aquamarine were used. The dose ranges from 10 kGy to 70 kGy. The epithermal neutron irradiation was performed at IEA-R1 research reactor at IPEN and MCP-LiF detectors were used to measure the absorbed dose. A method called UHTR (Ultra High Temperature Ratio) was employed for calculating the amount of energy absorbed by the dosimeter. The fluence of epithermal neutrons ranges from 1014 a 1017 n/cm².
72

An algorithm for multi-group two-dimensional neutron diffusion kinetics in nuclear reactor cores

Schramm, Marcelo January 2016 (has links)
O objetivo desta tese é introduzir uma nova metodologia para a cinética bidimensional multi- grupo de difusão de nêutrons em reatores nucleares. A metodologia apresentada usa uma aproximação polinomial em um domínio homogêneo retangular com condições de contornos não homogêneas. Como ela consiste em uma série de Taylor truncada, sua estimativa de erro varia de acordo com o tamanho do retângulo. Os coeficientes são obtidos principalmente pelas suas relações com o termo independente, que _e determinado pela equação diferencial. Estas relações são obtidas apenas pelas condições de contorno, e é demonstrado serem linearmente independentes. Um esquema numérico é feito para assegurar uma rápida convergência. Estes procedimentos feitos para um retângulo homogêneo são feitos para construir soluções para problemas de autovalor e dependentes do tempo de geometria ortogonal global com parâmetros seccionalmente constantes pelo método iterativo SOR. O autovalor dominante e sua autofunção são obtidos pelo método da potência no problema de autovalor. A solução para casos dependentes do tempo usam o método de Euler modificado na variável tempo. Quatro casos-teste clássicos são considerados para ilustração. / The objective of this thesis is to introduce a new methodology for two{dimensional multi{ group neutron diffusion kinetics in a reactor core. The presented methodology uses a polyno- mial approximation in a rectangular homogeneous domain with non{homogeneous boundary conditions. As it consists on a truncated Taylor series, its error estimates varies with the size of the rectangle. The coefficients are obtained mainly by their relations with the independent term, which is determined by the differential equation. These relations are obtained by the boundary conditions only, and these relations are proven linear independent. A numerical scheme is made to assure faster convergence. The procedures done for one homogeneous rectangle are used to construct the solution of global orthogonal geometry with step{wise constant parameters steady state and time dependent problems by the iterative SOR algo- rithm. The dominant eigenvalue and its eigenfunction are obtained by the power method in the eigenvalue problem. The solution for the time dependent cases uses the modi ed Euler method in the time variable. Four classic test cases are considered for illustration.
73

"Estrelas compactas e buracos negros - um estudo comparativo de propriedades físicas e de modos quasi-normais" / Compact Stars and Black Holes - A Comparative Study of Physical Properties and Quasi-Normal Modes

Giugno, Davi 18 July 2006 (has links)
Este trabalho visa o estudo das perturbações de sistemas gravitacionais altamente compactos, como buracos negros e estrelas de nêutrons e de quarks. As perturbações em questão podem ser de diversas naturezas (escalar, eletromagnética ou gravitacional), sendo que detivemo-nos mais atentamente naquelas de natureza gravitacional, pois estas têm despertado mais interesse por serem astronomicamente mais fáceis de detectar. Além de estudarmos tais perturbações, procedemos a uma comparação dos resultados para buracos negros, estrelas de nêutrons e de quarks. Tal comparação justifica-se pelo fato de que a confrontação de previsões teóricas com resultados experimentais pode ajudar-nos a identificar objetos astronômicos de interesse, distingüi-los e, no caso de estrelas, aprender algo sobre sua estrutura interna, particularmente sobre a equação de estado (EDE) do fluido estelar. No que se segue, dividimos o trabalho em sete partes. Em primeiro lugar, damos uma introdução bastante sucinta ao mesmo (Capítulo 1). Depois, falamos sobre a física de estrelas de nêutrons e de quarks (Capítulo 2). A seguir, fazemos um estudo comparativo dos dois tipos de estrelas (Capítulo 3). Mais adiante, discutimos as perturbações de diversos tipos, além de definir os MQNs (Modos Quasi-Normais) de buracos negros de Schwarzschild (Capítulo 4). Prosseguimos a discussão com a métrica de Reissner-Nordström-de Sitter (Capítulo 5) e introduzimos, na seqüência, os MQNs estelares, de forma muito breve (Capítulo 6). Por fim, apresentamos nossas conclusões (Capítulo 7). A parte inédita deste trabalho está concentrada nos capítulos 5 e 6, os quatro anteriores servindo de preparativo e de base comparativa para estes dois. / This work aims the detailed study of the perturbations of highly compact gravitational systems, such as black holes and both neutron and quark stars. Such perturbations may have several different characters, such as scalar and electromagnetic fields as well as gravitational (either axial or polar) disturbances. We have focused more closely on the latter kind of perturbation, since they offer better possibilities of detection in the near future, in the form of gravitational waves. Besides studying the aforementioned perturbations, we have proceeded to a comparison between black holes and neutron and quark stars , when it comes to the outcomes of the perturbations, usually called QNMs (quasi-normal modes). Such a comparison is actually in order, since a direct comparison of theoretical and observational data may help us identify astronomical objects and, in the case of compact stars, may provide valuable insights into these stars' inner structure, particularly when it comes to their equation of state (EOS). In what follows, we have subdivided this work in seven parts. We begin with a brief introduction (Chapter 1), then proceed to a description of the physics of both neutron and quark stars (Chapter 2) and, in the sequence, to a comparative study of both kinds of star (Chapter 3). Subsequently, we develop the perturbation theory of the Schwarzschild black holes, discussing their QNMs (Chapter 4) and doing the same, later, for a more general Reissner-Nordström-de Sitter geometry (chapter 5). After that, we provide a very brief introduction to the stellar MQNs (Chapter 6). Finally, we present our conclusions (Chapter 7). The chapters 5 and 6 carry the inedit part of this work, and the chapters from 1 to 4 pave the way and provide a comparative basis for them.
74

Análise da dosagem sérica de elementos traço e sua correlação com aspectos clínicos de uma população de idosos saudáveis / Analysis of serum trace elements and their correlation with clinical aspects of a population of healthy elderly

Jaluul, Omar 08 October 2010 (has links)
O interesse sobre o papel dos elementos traço na gênese de doenças, na mortalidade e na manutenção da saúde vem sendo cada vez maior. Este trabalho tem como objetivo determinar as concentrações séricas dos elementos: Br, Ca, Cl, Fe, Na, Rb, Se e Zn e correlacioná-las com os aspectos clínicos de uma população de idosos saudáveis. Foram considerados saudáveis os idosos sem senilidade sistêmica e sintomática, sendo selecionamos 101 idosos saudáveis, 33 (32,67%) homens e 68 (67,33%) mulheres com idade média de 71,7 ± 7,1 (60-98). O nível sérico de Se foi significativamente menor em pacientes mais idosos (p < 0.001). Em comparação com os valores de referência, o Br, Cl e Na apresentaram médias menores. Em relação ao sexo, os homens tiveram menores níveis de Br (p < 0,001) e de Se (p = 0,005) com maiores níveis de Fe (p < 0,001). Menores níveis de Se foram relacionados com menor escolaridade (p= 0.013). Os valores de Br estiveram muito abaixo dos valores de referência e a prática da atividade física correlacionou-se com menores níveis de Br (p= 0,008). Poderíamos questionar se os altos níveis de Br seriam prejudiciais ao envelhecimento saudável, se níveis baixos de bromo seriam marcadores de saúde em idosos ou até se existe relação entre hábitos de vida saudáveis com os níveis de Br. A partir dos 71,2 anos, os níveis séricos de selênio começam a cair mesmo em indivíduos saudáveis. Estudos adicionais deverão determinar se o monitoramento dos níveis séricos de selênio pode ser utilizado como marcador precoce do desenvolvimento de doenças e mortalidade / Concern about the role of trace elements in the genesis of disease, mortality and health maintenance has been increasing. This study aims to determine serum concentrations of the elements: Br, Ca, Cl, Fe, Na, Rb, Se and Zn and correlate them with clinical features of a population of healthy elderly. Were considered healthy elderly people without senile systemic symptoms. We selected 101 healthy elderly, 33 (32.67%) men and 68 (67.33%) women with a mean age of 71.7 ± 7.1 (60-98). The serum level of Se was significantly lower in older patients (p <0.001). Compared with the reference values Br, Cl and Na diminished. Longer averages about sex men had lower levels of Br (p <0.001) and Se (p = 0.005) with higher levels of Fe (p <0.001). If lower levels were associated with less education (p = 0.013). Br values were well below the reference values and physical activity correlated with lower levels of Br (p = 0.008). One might question whether high levels of Br would be detrimental for healthy aging, if low levels of bromine were markers of health in the elderly or even if there is a relationship between healthy lifestyle habits with the levels of Br. From 71.2 years, serum levels of selenium begin to fall even in healthy individuals. Additional studies will determine if monitoring of serum levels of selenium can be used as a marker of early development of disease and mortality
75

Dosimetria TL em campos mistos no reator IPEN/MB-01 / Mix field TL dosimetry at IPEN/MB-01 reactor

Cavalieri, Tássio Antonio 30 August 2018 (has links)
A dosimetria de campos mistos de nêutrons e gamas é uma área de pesquisa que apresenta grande oportunidade de estudos devido ao aumento da utilização de procedimentos médicos como protonterapia e Terapia de Captura de Nêutrons (NCT Neutron Capture Therapy), além da importância para cálculo de doses ocupacionais e dos campos de irradiação em reatores nucleares. Para a dosimetria de campos mistos de nêutrons e gamas, a Comissão Internacional de Unidades de Medidas (ICRU) recomenda o uso de dosímetros com sensibilidades distintas para cada componente do campo. Os dosímetros termoluminescentes (TLDs) apresentam-se como uma alternativa para a realização da dosimetria de campos mistos de nêutrons e gamas em particular à utilização do par de TLDs de LiF TLD 100 e TLD 700, que apresentam respostas distintas às componentes de campo em virtude da diferença na quantidade do isótopo 6Li em suas composições. Porém, esta escolha apresenta algumas dificuldades pois a característica da resposta dos TLDs para cada componente de campo ainda não é totalmente compreendida. Este trabalho apresenta primeiramente um estudo de um sistema para moderação de uma fonte de AmBe para realizar os estudos de sensibilidade e linearidade dos TLDs quando irradiados em um campo misto de nêutrons e gamas. O sistema de moderação se faz necessário pois a fonte de AmBe emite preferencialmente nêutrons com alta energia, e a sensibilidade dos TLDs de LiF é preferencialmente para nêutrons de baixa energia. Entretanto, um dos objetivos do Grupo de Pesquisa em Física Médica do CEN/IPEN é a realização da dosimetria de campos mistos de alta intensidade, como por exemplo, o campo proveniente de um reator nuclear. Dessa forma esse trabalho realizou um estudo das respostas dos TLDs 100 e TLDs 700 quando irradiados no interior do núcleo do reator IPEN/MB-01 em duas diferentes configurações: cilíndrica com \"flux trap\" e retangular num arranjo de 26 x 28 varetas combustíveis. Esse trabalho contou com simulações com o código de Monte Carlo, MCNP5, para fornecer os fluxos e doses devido a cada componente de campo ao qual os TLDs estariam expostos. E a partir dos dados obtidos tanto através das simulações, quanto através dos experimentos, foi proposta uma metodologia para a utilização do TLD 100 para a dosimetria de nêutrons em campos com alta fluência de nêutrons, como é o caso do núcleo do reator IPEN/MB-01. / Mixed radiation field dosimetry is a research area that presents a great opportunity for studies due to the increased use on medical procedures such as proton therapy and Neutron Capture Therapy (NCT), as well as the importance of calculating occupational doses and radiation fields in nuclear reactors. For the dosimetry of mixed fields of neutrons and gammas, the International Commission on Radiation Units and Measurements (ICRU) recommends the use of dosimeters with distinct sensitivities for each component of the field. Thermoluminescent dosimeters (TLDs) are presented as an alternative for the dosimetry of neutron and gamma-mixed fields. In particular, the use of LiF TLD pair TLD 100 and TLD 700, which present distinct responses to the field components due to the difference in the amount of the 6Li isotope in its compositions. However, this choice presents some difficulties because the characteristic of the TLD response for each field component is not fully understood. This work presents a study of a system for moderation of an AmBe source to perform the screening and linearity studies of the TLDs when irradiated in a mixed field of neutrons and gammas. The moderation system is necessary since the AmBe source preferably emits neutrons with high energy, and the sensitivity of the LiF TLDs is preferably for low energy neutrons. However, one of the objectives of the Monte Carlo and Dosimetry for Medical Physics Research Group of CEN / IPEN is to perform the dosimetry of high intensity mixed fields, such as the field from a nuclear reactor. Thus, this work carried out a study of the responses of the TLDs 100 and TLDs 700 when irradiated inside the core of the IPEN/MB-01 reactor in two different configurations: cylindrical with flux trap and rectangular in an arrangement of 26 x 28 fuel rods. This work relied on simulations with the Monte Carlo code MCNP5 to provide the fluxes and doses due to each field component in which the TLDs would be exposed. From the data obtained, both through the simulations and through the experiments, a methodology was proposed for the use of the TLD 100 for the neutron dosimetry in fields with high neutron fluence, such as the IPEN/MB-01.
76

Modelagem e simulação dos venenos no combustível nuclear em cenários com duas escalas de tempo

Espinosa, Carlos Eduardo January 2016 (has links)
A presente discussão e uma extensão do modelo de cinética pontual de nêutrons, onde a reatividade e decomposta em termos de contribuição de curtas e longas escalas de tempo. A primeira representa o controle operacional do reator, enquanto a segunda e devido a alteração da composição química do combustível nuclear, como consequência do burn-up. E um primeiro passo em uma nova direção, uma vez que considera os efeitos dos principais venenos na cinética de nêutrons, ou seja, Xenônio-135 e Sam ario-149. O modelo proposto consiste em um sistema de equações não-lineares acoplado para a densidade de nêutrons, para os precursores de nêutrons atrasados e para as cadeias de decaimento dos venenos produtos de fissão. O sistema de equações e resolvido através de um método de decomposição, que expande os termos não-lineares em uma série infinita, obtendo um sistema recursivo, onde a inicialização da recursão e uma equação linear homogênea e os passos de recursão subsequentes consideram contribuições não-lineares como termo fonte constru dos em passos de recursão anteriores. A construção hierárquica do modelo também e realizada, onde graus espaciais de liberdade são considerados. São apresentados casos de estudos com várias estruturas temporais afim de mostrar a robustez da abordagem atual para este tipo de problema. / The present discussion is an extension to Neutron point kinetics models, where the reactivity is decomposed in a short and a long term contribution. The rst one represents operational reactor control, whereas the second one is due to the change of the chemical composition of the nuclear fuel as a consequence of burn-up. This is a rst step into a new direction where we consider only the e ects of the principal neutron poisons on neutron kinetics, i.e, Xenon-135 and Samarium-149. The proposed model consists in a system of coupled nonlinear equations for the neutron density, the delayed neutron precursors and the neutron poison decay chains. The equation system is solved using a decomposition method, which expands the non-linear terms in an in nit series, obtaining a recursive system, where the recursion initialization is a homogeneous linear equation and the subsequent recursion steps consider the non-linear contributions as source terms constructed from previous recursion steps. A hierarchical construction of the model is also performed, where spatial degrees of freedom are considered. We present case studies with severe time structure in order to show the robustness of the present approach for this kind of problems.
77

Hidrodinâmica da combustão de matéria hadrônica em máteria de Quarks em estrelas de nêutrons

MANRIQUE, Marcos Antonio Albarracin January 2010 (has links)
Orientador: Gérman Lugones. / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós Graduação em Física, 2010.
78

Implementação do método k0-INAA no laboratório de análise por ativação com nêutrons do IPEN utilizando o programa k0-IAEA. Aplicação à análise de amostras geológicas / k0-NAA implementation and application at IPEN neutron activation laboratory by using the k0-IAEA software. Application to geological sample analysis

Davi Brigatto Mariano 01 February 2012 (has links)
O Laboratório de Análise por Ativação com Nêutrons (LAN-IPEN) vem analisando amostras geológicas, tais como rochas, solos e sedimentos, há vários anos, empregando o método de análise por ativação com nêutrons comparativa, visando estudos geoquímicos e ambientais. Este trabalho apresenta os resultados obtidos na implementação do método de padronização k0-INAA no LANIPEN, para a análise de amostras geológicas, utilizando o programa k0-IAEA, fornecido pela Agência Internacional de Energia Atômica (IAEA). A razão do fluxo de nêutrons térmico-epitérmico f e o fator &alpha; da distribuição de fluxo de nêutrons epitérmicos do reator IEA-R1 do IPEN foram determinados na estação pneumática de irradiação, e em uma posição de irradiação selecionada, para irradiações curtas e longas, respectivamente. Para obter esses fatores, foi utilizado o chamado método bare triple-monitor com 197Au-96Zr-94Zr. Para avaliar a exatidão e precisão do método, foram analisados os materiais geológicos de referência basalto JB-1 (GSJ) e BE-N (IWG-GIT), andesito AGV-1 (USGS), granito GS-N (ANRT), SOIL-7 (IAEA) e sedimento Buffalo River Sediment (NIST BRS-8704), que representam diferentes matrizes geológicas. Os resultados obtidos para até 30 elementos concordaram com os valores recomendados, com erros relativos (bias) menores que 10%, exceto no caso do Zn no AGV-1 (11,4%) e Mg no GS-N (13,4%). Os critérios estatísticos z-score, zeta-score e U-score foram aplicados para avaliação dos resultados. Pelo critério do z-score, os resultados obtidos puderam ser considerados satisfatórios (z<2), com exceção dos resultados obtidos para Mg no GS-N e no JB-1, e para Yb no Soil-7. O critério estatístico zeta-score se mostrou o mais restritivo, obtendo-se resultados questionáveis (2 < zeta < 3) para Mg no BE-N, Mn no GS-N e Yb no Soil-7, e resultados insatisfatórios (zeta>3) para Mn no BE-N, Mg, Ce e La no GS-N, Mg no JB-1, e Th e Eu no Buffalo River Sediment. Os valores de U-score mostraram que todos os resultados, com exceção do valor para Mg no JB-1, estão dentro de um intervalo de confiança de 95% (se for considerado 1,96 o valor limite para o Uteste para um nível de probabilidade de 95%). Estes resultados indicam excelentes possibilidades para o uso deste método paramétrico no LAN-IPEN para a análise de amostras geológicas em estudos geoquímicos e ambientais. / The Neutron Activation Analysis Laboratory (LAN-IPEN) has been analysing geological samples such as rocks, soils and sediments, for many years with the INAA comparative method, for geochemical and environmental research. This study presents the results obtained in the implementation of the k0-standardization method at LANIPEN, for geological sample analysis, by using the program k0- IAEA, provided by the International Atomic Energy Agency (IAEA). The thermal to epithermal flux ratio f and the shape factor &alpha; of the epithermal flux distribution of the IPEN IEA-R1 nuclear reactor were determined for the pneumatic irradiation facility and one selected irradiation position, for short and long irradiations, respectively. To obtain these factors, the bare triple-monitor method with 197Au- 96Zr-94Zr was used. In order to validate the methodology, the geological reference materials basalts JB-1 (GSJ) and BE-N (IWG-GIT), andesite AGV-1 (USGS), granite GS-N (ANRT), SOIL-7 (IAEA) and sediment Buffalo River Sediment (NISTBRS-8704), which represent different geological matrices, were analysed. The concentration results obtained agreed with assigned values, with bias less than 10% except for Zn in AGV-1 (11.4%) and Mg in GS-N (13.4%). Three different scores were used to evaluate the results: z-score, zeta-score and Uscore. The z-score showed that the results can be considered satisfactory (z<2), except for Mg in GS-N and JB-1, and for Yb in Soil-7. Zeta-score was the most restrictive criterion, indicating questionable results (2 < zeta < 3) for Mg in BE-N, Mn in GS-N and Yb in Soil-7, and unsatisfactory results (zeta>3) for Mn in BE-N, Mg, Ce and La in GS-N, Mg in JB-1, and Th and Eu in Buffalo River Sediment. The U-score test showed that all results, except Mg in JB-1, were within 95% confidence interval. These results indicate excellent possibilities of using this parametric method at the LAN-IPEN for geological samples analysis in geochemical and environmental studies.
79

Qualidade ambiental de solos agrícolas da bacia do Rio Jaguari -São Paulo / ENVIRONMENTAL QUALITY OF AGRICULTURAL SOILS WITHIN THE JAGUARI RIVER BASIN - SÃO PAULO

Elaine Cristina Ruby 26 November 2009 (has links)
Os impactos sobre o meio ambiente têm ocorrido de formas e intensidades variadas sobre os diferentes meios: solo, água e ar. Atualmente, diversos países utilizam critérios legais de proteção do solo, ou por meio de valores orientadores genéricos ou por meio de avaliação de risco caso a caso. No Brasil, em 2001, o Estado de São Paulo por meio da Companhia Ambiental (CETESB) foi pioneiro na publicação de valores orientadores para solos e águas subterrâneas. O objetivo desse trabalho foi avaliar a qualidade ambiental de solos agrícolas comparando-os com solos sob remanescentes e/ou fragmentos de mata, áreas-controle, na bacia do rio Jaguari - Estado de São Paulo tendo como base a legislação ambiental para o Estado de São Paulo. Esta avaliação ocorreu por meio da determinação de multielementos pela técnica de Análise por Ativação Neutrônica Instrumental-INAA, complementada pelas técnicas analíticas de Espectrometria Ótica de Emissão com Plasma de Argônio-ICP OES e Espectrometria de Absorção Atômica de Forno de grafite-GFAAS. Na comparação entre os resultados obtidos nas amostras de solo analisadas e os valores orientadores, constatou-se que não ocorreram concentrações medianas superiores aos valores de prevenção. Foi observado que para os elementos Sb, As, Cd, Pb, Co, Cu, Cr, Ni, V e Zn, as concentrações medianas ficaram abaixo dos valores de referência para o Estado de São Paulo, exceto para o Pb. Dos 34 elementos determinados, ocorreram diferenças estatisticamente significativas (p<0,05) entre os grupos, agrícola e mata, somente para os elementos Ba, As, U e V. Somente o Ba apresentou concentrações mais elevadas nos solos sob fragmentos de mata. Portanto, a qualidade ambiental dos solos agrícolas dessa bacia foi pouco alterada para os parâmetros determinados. Os elementos U e As podem ser utilizados como indicadores potenciais de contaminação em solos cultivados. / Environmental impacts have occurred in various forms and intensities on soil, water and air media. Consequently, several countries have used legal criteria for soil protection, either by means of generic guiding values or through case-by-case risk assessment. The São Paulo Environmental Agency (CETESB) pioneered the publication of guiding values for soils and groundwater in 2001. The aim of this study was to evaluate the environmental quality of agricultural soils in comparison to pristine soils (control areas) within the Jaguari river basin, São Paulo. The evaluation was carried out through multielement determination by Neutron Activation Analysis Instrumental (INAA) technique. The analyses were also complemented by Optical Emission Spectrometry Coupled Plasma (ICP OES), Atomic Absorption Spectrometry and Graphite Furnace (GFAAS) techniques. The results obtained in the analyzed soil samples were compared to the guiding values established by the São Paulo State environmental legislation and revealed that there were no median concentrations above the prevention values. The median concentrations for the elements Sb, As, Cd, Pb, Co, Cu, Cr, Ni, V and Zn were below the reference values, except for Pb. Taking into account the 34 elements determined, there were statistically significant differences (p <0.05) between agricultural and pristine soils only for the elements Ba, As, U and V. Among these elements, Ba presented the highest concentrations in pristine soils. It was concluded, that the environmental quality of agricultural soils within the Jaguari river basin - SP was slightly changed for the given parameters. The results also pointed out for the utilization of U and As as indicators of potential contamination in soils.
80

Estabelecimento e caracterização de um laboratório de calibração com campos neutrônicos de referência com rastreabilidade ao sistema metrológico internacional / Establishment and characterization of a calibration laboratory with reference neutron beams and traceability to the international metrology system

Tallyson Sarmento Alvarenga 23 August 2018 (has links)
No Brasil, atualmente só há um laboratório de calibração de monitores de radiação de nêutrons, sendo responsável pela guarda e manutenção do padrão brasileiro da fluência de nêutrons, localizado no Laboratório Nacional de Metrologia das Radiações Ionizantes (LNMRI), Rio de Janeiro, no Instituto de Radioproteção e Dosimetria, Comissão Nacional de Energia Nuclear, Rio de Janeiro, com uma demanda grande de serviços com esse tipo de radiação. Com o intuito de descentralizar a oferta de serviços de calibração, surgiu a necessidade da montagem de um segundo Laboratório de Calibração com Nêutrons (LCN), no IPEN. Nas situações práticas envolvendo a calibração de monitores de radiação de nêutrons, um dos problemas principais está relacionado à radiação espalhada, que pode variar dependendo das dimensões do laboratório usado nos procedimentos de calibração. No processo de caracterização do campo de radiação de nêutrons da fonte de 241AmBe, onde foi realizada a avaliação dos espectros, das energias, das taxas de fluência, das taxas de equivalente de dose ambiente [H*(10)] e do coeficiente de conversão de fluência em dose [h*&phi;(10)] em diferentes posições do LCN, utilizando o feixe completo. A influência da radiação espalhada foi determinada por meio de três técnicas: Métodos de Monte Carlo, de Ajuste Reduzido e do Cone de Sombra. Dos resultados obtidos por meio de simulação e experimentalmente foi possível obter a fração de espalhamento em diferentes distâncias fonte-detector. / In Brazil, there is currently only one calibration laboratory for neutron radiation monitors. It is responsible for the custody and maintenance of the Brazilian neutron fluence standard, located at the Laboratório Nacional de Metrologia das Radiações Ionizantes-LNMRI, Rio de Janeiro, at the Instituto de Radioproteção e Dosimetria, Comissão Nacional de Energia Nuclear, with a great demand of services with this type of radiation. In order to decentralize the calibration service offer, it was necessary to set up a second Neutron Calibration Laboratory (LCN), at IPEN. In practical situations involving the calibration of neutron radiation monitors, one of the main problems is related to scattered radiation, which may vary depending on the size of the laboratory used for the calibration procedures. In the process of characterization of the neutron radiation field of the 241AmBe source, the spectra, the energies, the fluence rate, the ambient dose equivalent rate and the conversion coefficient of fluence in dose at different positions of the LCN, were evaluated using the complete beam. The influence of the scattered radiation was determined by three techniques: Monte Carlo Method, the Reduced Adjustment Method and the Shade Cone Method. From the results obtained through simulation and experimentally, it was possible to obtain the scattering fraction at different source-detector distances.

Page generated in 0.0352 seconds